You are on page 1of 1

NAIMAT PHASE-4 GLYCOL DEHYDRATION UNIT

VESSELS
Inside Diameter Height/Length Liquid Level (Norm) Flow Retention Time Liq Volume Gas Handling Capacity Liquid Handling Capacity Liquid Droplets in Gas
Sr.No. Equipment Tag Equipment Description Orientation
mm in mm f mm f Usgpm f3/min min f3 MMSCFD BBLD Microns
1 T-1000 Glycol Absorber/scrubber Vertical 1219 48 23400 30 366 1.2 #DIV/0! #DIV/0!
2 F-1030 Filter Seperator Horizontal 914 36 3810 12.5 488 1.6 #DIV/0! #DIV/0! 95 - 200
3 MBF-1200 Fuel Gas Scrubber Vertical 253 9.96 610 2 #DIV/0! #DIV/0! 0.3 22 150
4 MBD-1300 Pump gas Seperator Horizontal 1067 42 3658 12 #DIV/0! #DIV/0! 15 1252 glycol+145condesate 150
5 V-1090 Dry/Gas Scrubber Vertical 1372 54 3048 10 640.08 2.1 #DIV/0! #DIV/0! 100 3490 600
HEAT EXCHANGER/COOLER
Duty Fan Power
Sr.No. Equipment Tag Equipment Description Type
MMBTU/hr HP
1 E-1010 Gas Glycol exchanger DP Heat Exchanger 0.5 NA
2 E-130001 Lean TEG cooler Air Cooler 2.676 33.2 X 2
3 BBC-1100 TEG reboiler Direct Fired Reboiler 2 NA
4 HBG-1600 Gly/Gly Exchanger Shell and Tube Heat Exchanger 1.8 NA
PUMPS
Capacity Power(Motor)
Sr.No. Equipment Tag Equipment Description Type RPM
USGPM Hp
1 PBA-1700A/B Glycol Pumps PD 28 1800 NA
2 P-XXXA/B Booster Pumps Centrifugal 32 1800 3 (Not procurred yet)
FILTERS
Capacity(ma
Sr.No. Equipment Tag Equipment Description Orientation x) Dia Height
USGPM mm f mm f
1 MAJ-1500 Glycol Sock Filter Vertical 28 406 1.3 1499 4.9
2 MAJ-1400 Charcoal Filter Vertical 14 914 3 1372 4.5