Professional Documents
Culture Documents
As Found Units
Meter Identification
Meter # SGT-002
Field
Well
Lease DINAMIS 1
Meter Tag FM-SGT-120MW
Date 7/8/2017
Time 2:25:00 PM
Standards Used
Calculation Type
Volume Flow Rate
Summary
$$$$$$
Daily $14,694.57 US $/Day
Monthly $446,959.75 US $/Month
Yearly $5,363,517.00 US $/Year
Flow Rate
Volume Flow Rate at base conditions, Qb 382,059.900 scf/hr
Volume Flow Rate at base conditions, Qb 9.169 MMscfd
Heating Value
Gross Heating Value, HV 1,033.909 Btu/scf
Net Heating Value, HVNET 923.131 Btu/scf
Meter Data
Hardware
Orifice Bore Diameter @ Tr, dr 2.690 in
Meter Tube Diameter @ Tr, Dr 4.026 in
Beta Ratio 0.668
Operating Conditions
Temperature 81.426 F
Page 1
As Found Report
As Found Units
Flowing Pressure (Gage/Absolute) Gage
Atmospheric Pressure 14.730 psia
Pressure (Upstream) 368.002 psia
Pressure (Downstream) 364.739 psia
Differential Pressure 90.393 inh2o
Reference - Temperature
Meter Tube Diameter Meas. Temp., Tr 68.000 F
Orifice Diameter Meas. Temp., Tr 68.000 F
Taps
Type of Taps Flange
Location of Taps Downstream
Characterization Method
Default
Page 2
As Found Report
As Found Units
Meter Identification
Meter # SGT-002
Field
Well
Lease DINAMIS 2
Meter Tag FM-SGT-120MW
Date 7/8/2017
Time 2:25:00 PM
Standards Used
Calculation Type
Volume Flow Rate
Summary
$$$$$$
Daily $14,600.84 US $/Day
Monthly $444,108.98 US $/Month
Yearly $5,329,307.72 US $/Year
Flow Rate
Volume Flow Rate at base conditions, Qb 379,623.067 scf/hr
Volume Flow Rate at base conditions, Qb 9.111 MMscfd
Heating Value
Gross Heating Value, HV 1,033.909 Btu/scf
Net Heating Value, HVNET 923.131 Btu/scf
Meter Data
Hardware
Orifice Bore Diameter @ Tr, dr 2.690 in
Meter Tube Diameter @ Tr, Dr 4.026 in
Beta Ratio 0.668
Operating Conditions
Temperature 81.442 F
Page 1
As Found Report
As Found Units
Flowing Pressure (Gage/Absolute) Gage
Atmospheric Pressure 14.730 psia
Pressure (Upstream) 367.955 psia
Pressure (Downstream) 364.734 psia
Differential Pressure 89.249 inh2o
Reference - Temperature
Meter Tube Diameter Meas. Temp., Tr 68.000 F
Orifice Diameter Meas. Temp., Tr 68.000 F
Taps
Type of Taps Flange
Location of Taps Downstream
Characterization Method
Default
Page 2
As Found Report
As Found Units
Meter Identification
Meter # SGT-002
Field
Well
Lease DINAMIS 3
Meter Tag FM-SGT-120MW
Date 7/8/2017
Time 2:25:00 PM
Standards Used
Calculation Type
Volume Flow Rate
Summary
$$$$$$
Daily $14,673.76 US $/Day
Monthly $446,326.87 US $/Month
Yearly $5,355,922.47 US $/Year
Flow Rate
Volume Flow Rate at base conditions, Qb 381,518.918 scf/hr
Volume Flow Rate at base conditions, Qb 9.156 MMscfd
Heating Value
Gross Heating Value, HV 1,033.909 Btu/scf
Net Heating Value, HVNET 923.131 Btu/scf
Meter Data
Hardware
Orifice Bore Diameter @ Tr, dr 2.690 in
Meter Tube Diameter @ Tr, Dr 4.026 in
Beta Ratio 0.668
Operating Conditions
Temperature 81.122 F
Page 1
As Found Report
As Found Units
Flowing Pressure (Gage/Absolute) Gage
Atmospheric Pressure 14.730 psia
Pressure (Upstream) 367.985 psia
Pressure (Downstream) 364.734 psia
Differential Pressure 90.080 inh2o
Reference - Temperature
Meter Tube Diameter Meas. Temp., Tr 68.000 F
Orifice Diameter Meas. Temp., Tr 68.000 F
Taps
Type of Taps Flange
Location of Taps Downstream
Characterization Method
Default
Page 2
As Found Report
As Found Units
Meter Identification
Meter # SGT-002
Field
Well
Lease DINAMIS 4
Meter Tag FM-SGT-120MW
Date 7/8/2017
Time 2:25:00 PM
Standards Used
Calculation Type
Volume Flow Rate
Summary
$$$$$$
Daily $14,570.33 US $/Day
Monthly $443,180.88 US $/Month
Yearly $5,318,170.61 US $/Year
Flow Rate
Volume Flow Rate at base conditions, Qb 378,829.736 scf/hr
Volume Flow Rate at base conditions, Qb 9.092 MMscfd
Heating Value
Gross Heating Value, HV 1,033.909 Btu/scf
Net Heating Value, HVNET 923.131 Btu/scf
Meter Data
Hardware
Orifice Bore Diameter @ Tr, dr 2.690 in
Meter Tube Diameter @ Tr, Dr 4.026 in
Beta Ratio 0.668
Operating Conditions
Temperature 81.964 F
Page 1
As Found Report
As Found Units
Flowing Pressure (Gage/Absolute) Gage
Atmospheric Pressure 14.730 psia
Pressure (Upstream) 367.941 psia
Pressure (Downstream) 364.729 psia
Differential Pressure 88.979 inh2o
Reference - Temperature
Meter Tube Diameter Meas. Temp., Tr 68.000 F
Orifice Diameter Meas. Temp., Tr 68.000 F
Taps
Type of Taps Flange
Location of Taps Downstream
Characterization Method
Default
Page 2
As Found Report
As Found Units
Meter Identification
Meter # SGT-002
Field
Well
Lease DINAMIS 5
Meter Tag FM-SGT-120MW
Date 7/8/2017
Time 2:25:00 PM
Standards Used
Calculation Type
Volume Flow Rate
Summary
$$$$$$
Daily $14,612.51 US $/Day
Monthly $444,463.92 US $/Month
Yearly $5,333,567.00 US $/Year
Flow Rate
Volume Flow Rate at base conditions, Qb 379,926.469 scf/hr
Volume Flow Rate at base conditions, Qb 9.118 MMscfd
Heating Value
Gross Heating Value, HV 1,033.909 Btu/scf
Net Heating Value, HVNET 923.131 Btu/scf
Meter Data
Hardware
Orifice Bore Diameter @ Tr, dr 2.690 in
Meter Tube Diameter @ Tr, Dr 4.026 in
Beta Ratio 0.668
Operating Conditions
Temperature 82.274 F
Page 1
As Found Report
As Found Units
Flowing Pressure (Gage/Absolute) Gage
Atmospheric Pressure 14.730 psia
Pressure (Upstream) 367.955 psia
Pressure (Downstream) 364.723 psia
Differential Pressure 89.556 inh2o
Reference - Temperature
Meter Tube Diameter Meas. Temp., Tr 68.000 F
Orifice Diameter Meas. Temp., Tr 68.000 F
Taps
Type of Taps Flange
Location of Taps Downstream
Characterization Method
Default
Page 2