You are on page 1of 6

Product Solution Catalog

(Field Instruments and Analyzers)

Bulletin 00A03B02-01E

www.yokogawa.com
Field Instruments
Pressure Transmitters
DPharp EJX Series Differential Pressure DPharp EJA-E Series Differential Pressure
and Pressure Transmitters and Pressure Transmitters

Liq Liq
Gas Gas
Stm Stm

 Ultra-high performance, the flag-ship model of DPharp.  A best-selling pressure transmitter series featuring silicon reso-
• High accuracy and fast response. nant sensor.
 Unique features include; • Fast response, corresponding to various applications.
• Multi-sensing (Differential pressure and Static pressure). • Excellent long term stability slashes maintenance cost.
• Output signal characterizer.  Unique features include;
• Multi-functional indicator with local parameter setting function • Multi-sensing (Differential pressure and Static pressure).
(optional). • Output signal characterizer.
• Alarm output for measured pressure and static pressure • Multi-functional indicator with local parameter setting function
(optional). (optional).
 High reliability. • SIL2 capable.
• SIL2 certified by TÜV. • 1 to 5 V low power output type available.

Temperature Transmitters Field Wireless Infrastructure


YFGW410 YFGW510
YTA Series Temperature Transmitters Field Wireless Field Wireless
Management Station Access Point

Field mount type  Single or redundant configuration with YFGW410


 Built to last: Dual-compartment housing realizes high resistance capabil-  Redundant switch over less than 1 second by
ity to harsh environments. YFGW410
 Safety first: SIL2 certified right out of the box - At Yokogawa safety is not
an option.  Highly reliable redundant communication : DUOCAST
 Excellent long term stability: Industry leading 5 year stability guaranty.  Management of 20 YFGW510s (max.) by YFGW410
Head mount type  Management of 500 wireless devices (max.) by
 A head mount type conforms to the standard DIN form B head mounting. YFGW410
Panel mount type  Management of 100 wireless devices (max.) by
 A panel mount type conforms to the standard DIN rail mounting and sup- YFGW510
ports HART communication protocol.

Field Wireless IO devices


FN310 FN510 EJX B Series YTA510 YTMX580
Wireless Differential
Field Wireless Field Wireless Pressure/Pressure Wireless Temperature Multi-Input Temperature
Multi-Protocol Module Multi-Function Module Transmitter Transmitter Transmitter

Wired HART DI / DO, AI Liq


transmitter
Pulse count Gas
MODBUS Stm
device Vibration
(SENCOM) sensor
(LN01)

Function Function Function


 Convert wired transmitter, sensor or device to wireless  Sensor is identical to wired transmitter  8 analog inputs
Common Functions
 ISA100 WirelessTM certified device
 Network Topology --- Star, Mesh, Designed mesh (mesh route is designed manually)
 Power supply --- Battery or supply from HART BUS line
 Function as network device --- IO auto, IO, IO and repeater, repeater
 Update period --- from 0.5 to 3600 seconds (depend on function)
 Ex Certification --- ATEX, FM, CSA, IECEx
Gas Analyzers
Gas Chromatograph Oxygen Analyzers
GC8000 ZR402/ZR202 AV550G
Process Gas Chromatograph Zirconia Oxygen Analyzers Averaging Converter
ZR402G  Capable of accepting in-
puts from up to 8 oxygen
detectors and 8 individ-
ual outputs are available
ZR22G/S  Averaging of multiple
point oxygen measure-
ments is ideally suited for combustion control
ZR202G/S
 Measurement with probe directly inserted
into furnace or boiler OX400
Touch Panel
 Integrated and separate types available Low Concentration Zirconia Oxygen Analyzer
 Also can be used as a high temperature hu-  Capable of measuring
midity analyzer a wide range of con-
 Fully field-repairable probe centrations, from 0-10
ppm up to 0-100 vol%
 HART communication
O2.
 Explosionproof (FM, CSA, ATEX) (ZR22S,
 Oxygen concentration
ZR202S)
control in semiconductor-related diffusion
and drying furnaces and in LCD manufactur-
MG8G/MG8E ing processes
Paramagnetic Oxygen Analyzers
OX100/OX102
 Fast analysis with Max. 3 ovens. Limiting Current Type Oxygen Analyzers
 Parallel GC by GC Module concept.
 Ideally suited for measuring
 The large 12.1 inch color LCD touch screen. oxygen concentrations of
 Ideally suited for measuring oxygen concen- N2 purged flow-sol-
trations of flammable gases dering machine,
 MG8E has flameproof construction etc.

Laser Analyzers Gas Density Meter Gas Calorimeter Dust Monitor


TDLS8000 GD402/GD40 CM6G DT450G
Tunable Diode Laser Spectrometer Gas Density Meter Gas Calorimeter Dust Monitor
 Measures
gas densi-
ty with
high sen-
sitivity and
quick re-
sponse.
Also capa-
 Automatic range
ble of dis-
setup and no manual
playing specific gravity and molec-
adjustment required
ular weight derived from the den-
sity data.  Triboelectric detec-
 Ideally suited for tion method unaffect-
 Can be used in hazardous areas
measuring calorific ed by dust adhesion
with explosive atmospheres (FM,
 In-line analysis of gases of O2, CO, CH4, CSA, TIIS) values of gases in ap-  For bag filter detec-
NH3, H2O, and many more NIR absorb- plications including tion and adjustment
 Hydrogen purity and replacement
ing gases in refinery and petrochemical. city gas and iron & of electrostatic pre-
meter for power generators
steel gas cipitator efficiency
 Large HMI provides easy operation and
control of up to 4 analyzers at the same
time
 IEC61508 SIL designed & approved,
Infrared Gas Analyzers
SIL 2
 IECEx, ATEX, cFMus hazardous area IR202/IR200/IR400 NDIR Type Infrared Gas Analyzers
approvals based on Nonincendive/Type
n and flameproof
 HART and Modbus TCP communica-
tions standard

IR202 IR200 IR400


Measuring Components
 IR202: NO, SO2, CO2,  IR200: CO2, CO, CH4,  IR400: NO, SO2, CO2,
CO, CH4, O2 SO2, NO, O2 CO, CH4, O2
Field Instruments Liquid Analyzers
Flowmeters Level Transmitters pH/ORP Analyzers Conductivity Analyzers
ROTAMASS Total Insight ADMAG Total Insight Series EJXC80A/EJAC80E EJXC80A/EJAC80E PH450G FLXA202/FLXA21 PH71/PH72 pH/ORP Sensors SC450G DC402G FLXA202/FLXA21 ISC450G FLXA202/FLXA21 ISC40G/S SC72
Conductivity
Coriolis Mass Flowmeter AXG and AXW Magnetic Flowmeter Diaphragm Seal System Diaphragm Seal System 4-Wire pH/ORP 2-Wire pH/ORP Personal pH, for 4-Wire Conductivity/ Dual Cell Conductivity/ 2-Wire Conductivity 4-Wire Inductive 2-Wire Inductive Inductive Personal
Sensors
(Direct Mount Seal) (Remote Mount Seal) Converter Transmitter pH/ORP Meters Process Use Resistivity Converter Resistivity Converter Transmitter Conductivity Converter Conductivity Transmitter Conductivity Sensors Conductivity Meter
Liq Liq SC4A-AD-09
Gas Liq Liq

SC4A-AD-15

FU24F FU20F SC25F


SENCOM® digital sensor SC4A-SA
ROTAMASS Nano ROTAMASS Prime ROTAMASS Giga
 Mass flow for nearly all flowing fluids. Total Insight concept provides:  The ADMAG Total Insight series AXG  The AXG is ideal for industrial process lines like  Large, high-resolution  Waterproof (IP67) con- PH8EFP/  Large, high-resolution  Differential, ratio or cal-  Large, high-resolution  Measuring range: 100  Intelligent, portable
and AXW adopt the "Total Insight" oil&gas/chemical/pulp&paper/food&beverage/ graphical display and struction allows mea- PH8ERP graphical display and culated outputs graphical display and SC4A-SB µS/cm 1999 mS/cm conductivity meter with
 Vibration-resistant due to counterbalanced dou-  Six dedicated product lines offering best-suited
solutions. concept and totally support the prod- metal&mining applications, and the AXW is for touchscreen operation surement in wet envi- FU20 touchscreen operation  Universal touchscreen operation with a single sensor waterproof (IP67) con-
bletube measurement system.
uct life cycle. The functions will in- general industrial process lines and water for ease of use ronment for ease of use conductivity/resistivity, for ease of use  Material: PEEK or Tef- struction
 Wizard for easy setup and configuration. crease customer’s benefits with re- supply/sewage applications.
 Sensor design with low pressure loss.  Diagnostic functions  Various convenient  Diagnostic functions software switchable  Diagnostic functions lon (PFA)  Various convenient
 “Event Management” for pro-active operation. ducing total cost of ownership. for minimum mainte- functions: 300-point for minimum mainte- for minimum mainte- SC210G functions: 300-point
 High accuracy measurement,  The AXG and/or AXW provide four I/O signals,  Matrix temperature
 Patented* “Tube Health Check” for in-line meter  The AXG and AXW are a high-quality calorie calculation, data logging, NAMUR NE nance data memory, alarm nance nance data memory, alarm
Mass flow: 0.1%, Density: 0.0005 g/cm3 compensation for pure
verification. *JP 4952820 B2 and highly reliable product developed 107, built-in verification, application diagnostics,  Flange-mounting, compact differential  Ideal for measuring the levels and densi-  Temperature compen- clock, etc. * Temperature com- water applications * Temperature com-  Appropriate sensor for clock, etc.
 Wide temperature range  MicroSD card for easy data transfer. based on years of experience and and data transfer by microSD card. pressure transmitter. ties of corrosive and high-temperature pensation, predefined pensation and pre- your application
sation and predefined  Easy to use EXA con-
(–70°C to 350°C). fluids.  12 languages. OIML buffer tables,  12 languages. defined OIML buffer ta-  12 languages.
 Worldwide approvals. achievement by our proprietary dual  Direct mounting to a tank. pH buffer tables for trol panel
frequency excitation method. best accuracy  Touch screen display. cell fouling monitoring  Touch screen display. bles for best accura-  Touch screen display.
 Small flange size model available.
 Small flange size model available.  Two sensors can be  Appropriate sensor for for best accuracy  USP<645> monitoring
 Two sensors can be
cy.
 8 languages
digitalYEWFLO ADMAG AXF ADMAG AXR connected. your application connected.  8 languages

Vortex Flowmeter Magnetic Flowmeter 2-wire Magnetic Flowmeter EJXC40A


Digital Remote Sensor
Liq Liq Liq
Turbidity Analyzers Chlorine Analyzers Dissolved Oxygen Analyzers
Gas Liq TB750G TB400G FC400G FC500G RC400G DO402G FLXA202/FLXA21 DO70G/DO30G
Stm Right Angle Scattered Scattered-Light Free Available Chlorine Free Available Chlorine Residual Chlorine 4-Wire Dissolved 2-Wire Dissolved Dissolved Oxygen
Multi-variable Reduced Light Turbidity Analyzer Turbidity Analyzer Analyzer Analyzer Analyzer Oxygen Converter Oxygen Transmitter Sensors
type bore type

 Spectral signal processing automatically op-  Built-in temperature sensor within the shed-  "Dual Frequency Excitation Method"  An extra AC power supply is not neces-
timizes the settings at all times, from imme- der bar offers the mass flow output or the realizes the stable measurement of sary. 2-wire loop powered performance
diately after power-on. temperature output. high concentration slurry fluid and allows direct connection to DCS I/O card
low conductivity fluid. possible, thus drastically reducing the ini-  Connecting two pressure sensors, master (high pressure side) and slave (low pressure DO70G
 Self-diagnostics, one step ahead of other  No installation of the temperature device is
tial cost and power consumption. side) in a remote location, with DRS dedicated communication cable to measure differen-
flowmeters, enables predictive mainte- needed for the process.  User-friendly functions; such as an
nance. electrode adhesion level diagnosis  AXR has SIL2 Safety Integrity Level (IEC tial pressure. DO30G
 Durable meter design mostly meets the
function, infra-red switches which 61508) certified. AXR is capable of SIL2  Suitable for level measurement of a tall tank. DRS cable length (maximum): 45 m
 Simultaneous analog and pulse signal out- steam flow such as water hammer, high  Non-reagent Type  Non-reagent Type  Measurement object: Measurement
can be used for setting parameters single use and SIL3 redundant use, as
puts. temperature process, etc.  Signal characterization for various tank types.  Polarographic method using rotating  Polarographic method using rotating  Long-term stable sensor of dissolved oxygen in aeration
without opening the case cover. standard.
gold electrode gold electrode tanks at sewage treatment plants.
 High-temperature and cryogenic models  Reduced bore type measures lower flow-  Display unit in mg/l, ppm, or % sat-
 User configurable measuring range  Surface scattered light method using  Reagent Type  Measuring range:
also available. rate.  Ideal for measurement of free avail-  Ideal for measurement of free avail- uration
from 0-0.2 NTU to 0-100 NTU. kaolin, formazin, or PSL  Polarographic method using rotating 0 to 25mg/l (ppm) (DO70G),
able chlorine in water supply and able chlorine in water supply and
Converter Configuration Tool
(polystyrene latex) for calibration  Temperature compensation, salt 0 to 20mg/l (ppm) (DO30G)
 Highly reliable measurement with platinum electrode
ROTAMETER EJA/EJX Series Differential EJX910A excellent linearity and repeatability.  Highly reliable measurement at wa-
distribution systems distribution systems concentration compensation and
 Type of sensor:
 Field-configurable from 0-1 to 0-3  Measuring range selectable:  Ideal for measurement of residual barometric air pressure compensa-
Variable Area Flowmeter Pressure Transmitters Multivariable Transmitter  In-line connection available ter supply and sewage systems
mg/l for two switchable output rang- 0-1/0-2/0-3 mg/l switchable or chlorine in chlorination processes of tion for best accuracy Optical DO sensor (DO70G),
PK200 FieldMate  Easy-to-clean cell  Measuring range: 0-2 to 0-2000 mg/l es 0-5/0-10 mg/l switchable water supply systems and in cooling  12 languages. Galvanic cell DO sensor (DO30G)
 Ideal for measurement of dissolved
Liq Liq Current-to-Pneumatic Converter Versatile Device Management Wizard (or degrees, unit selectable)
 Micro processor-based, intelligent
water of thermal power stations
oxygen in aeration tanks at sewage  Touch screen display.
converter  Measuring range: 0 to 10mg/l treatment plants, etc.  Two sensors can be connected.
Gas Gas
Stm Stm
MLSS Analyzer Liquid Density Meter FT-Near Infrared Analyzers
SS400G DM8 InfraSpec NR800
MLSS Analyzer Vibration Type Liquid Density Meter Fourier Transform Near Infrared Analyzers
 Complete stainless steel design.  Combined with an orifice, measures  Fully compensated mass flow: all flow
liquid, gas, and steam flow rates. factors can be automatically and dynami-  Electronic feedback system achieving high reliability  FieldMate is a field work-oriented software program for configuring,  Wide measuring range from 0-1000 mg/l to 0-20000 mg/l  Measures liquid density with high sensitivity and sta-  Continuous, multiple, and simulta-  Barcode reader provides easy oper-
 Local indication and analog output. and high performance. daily patrol, troubleshooting, and managing a wide variety of field bility neous measurement of component ation for at-line and routine analyses
cally calculated to an optimal value.  Ideal for measurement of mixed liquor suspended solids
 Available for direct mounting without devices used in production plants and test laboratories. (MLSS) in an aeration tank of activated sludge processes  Measuring range of 0.5 to 2.0 g/cm3 unaffected by concentration and property values  Reduces operating and maintenance
 Various process connections and wetted  Energy-saving design achieve economy.
three-valve manifold.  1.0% mass flow rate accuracy over 1:10 in sewage and industrial wastewater treatment facilities flow rate and viscosity (density, polymerization degree, costs by consolidation of lab and
materials.  Multi-protocol access support
flow range. octane value, etc.) of various pro- At-line Model
 Outstanding long-term stability slashes  Designed to be replacement-compatible with the  Detector is available in general-purpose, sanitary, process calibration models and on-
 Options such as Exi-version, inductive FOUNDATION™ fieldbus H1, BRAIN, HART, ISA100 Wireless™, cesses
maintenance costs.  Simultaneous dual output of 4 to 20 mA former model 5502. PROFIBUS, Modbus and flameproof types site hands-on training
alarms, pulse output, etc.  Measurement of trace water con-
and pulse signals for total flow, flow rate,
 Easy to operate…..one side access.  FieldMate Lite, a trial version of FieldMate, is available for download. tent available
or alarm status.
http://www.yokogawa.com/fieldmate/
Note: Liq , Gas , and Stm symbols indicate applicable process fluid types (liquid, gas, steam). On-line Model
Field Instruments Liquid Analyzers
Flowmeters Level Transmitters pH/ORP Analyzers Conductivity Analyzers
ROTAMASS Total Insight ADMAG Total Insight Series EJXC80A/EJAC80E EJXC80A/EJAC80E PH450G FLXA202/FLXA21 PH71/PH72 pH/ORP Sensors SC450G DC402G FLXA202/FLXA21 ISC450G FLXA202/FLXA21 ISC40G/S SC72
Conductivity
Coriolis Mass Flowmeter AXG and AXW Magnetic Flowmeter Diaphragm Seal System Diaphragm Seal System 4-Wire pH/ORP 2-Wire pH/ORP Personal pH, for 4-Wire Conductivity/ Dual Cell Conductivity/ 2-Wire Conductivity 4-Wire Inductive 2-Wire Inductive Inductive Personal
Sensors
(Direct Mount Seal) (Remote Mount Seal) Converter Transmitter pH/ORP Meters Process Use Resistivity Converter Resistivity Converter Transmitter Conductivity Converter Conductivity Transmitter Conductivity Sensors Conductivity Meter
Liq Liq SC4A-AD-09
Gas Liq Liq

SC4A-AD-15

FU24F FU20F SC25F


SENCOM® digital sensor SC4A-SA
ROTAMASS Nano ROTAMASS Prime ROTAMASS Giga
 Mass flow for nearly all flowing fluids. Total Insight concept provides:  The ADMAG Total Insight series AXG  The AXG is ideal for industrial process lines like  Large, high-resolution  Waterproof (IP67) con- PH8EFP/  Large, high-resolution  Differential, ratio or cal-  Large, high-resolution  Measuring range: 100  Intelligent, portable
and AXW adopt the "Total Insight" oil&gas/chemical/pulp&paper/food&beverage/ graphical display and struction allows mea- PH8ERP graphical display and culated outputs graphical display and SC4A-SB µS/cm 1999 mS/cm conductivity meter with
 Vibration-resistant due to counterbalanced dou-  Six dedicated product lines offering best-suited
solutions. concept and totally support the prod- metal&mining applications, and the AXW is for touchscreen operation surement in wet envi- FU20 touchscreen operation  Universal touchscreen operation with a single sensor waterproof (IP67) con-
bletube measurement system.
uct life cycle. The functions will in- general industrial process lines and water for ease of use ronment for ease of use conductivity/resistivity, for ease of use  Material: PEEK or Tef- struction
 Wizard for easy setup and configuration. crease customer’s benefits with re- supply/sewage applications.
 Sensor design with low pressure loss.  Diagnostic functions  Various convenient  Diagnostic functions software switchable  Diagnostic functions lon (PFA)  Various convenient
 “Event Management” for pro-active operation. ducing total cost of ownership. for minimum mainte- functions: 300-point for minimum mainte- for minimum mainte- SC210G functions: 300-point
 High accuracy measurement,  The AXG and/or AXW provide four I/O signals,  Matrix temperature
 Patented* “Tube Health Check” for in-line meter  The AXG and AXW are a high-quality calorie calculation, data logging, NAMUR NE nance data memory, alarm nance nance data memory, alarm
Mass flow: 0.1%, Density: 0.0005 g/cm3 compensation for pure
verification. *JP 4952820 B2 and highly reliable product developed 107, built-in verification, application diagnostics,  Flange-mounting, compact differential  Ideal for measuring the levels and densi-  Temperature compen- clock, etc. * Temperature com- water applications * Temperature com-  Appropriate sensor for clock, etc.
 Wide temperature range  MicroSD card for easy data transfer. based on years of experience and and data transfer by microSD card. pressure transmitter. ties of corrosive and high-temperature pensation, predefined pensation and pre- your application
sation and predefined  Easy to use EXA con-
(–70°C to 350°C). fluids.  12 languages. OIML buffer tables,  12 languages. defined OIML buffer ta-  12 languages.
 Worldwide approvals. achievement by our proprietary dual  Direct mounting to a tank. pH buffer tables for trol panel
frequency excitation method. best accuracy  Touch screen display. cell fouling monitoring  Touch screen display. bles for best accura-  Touch screen display.
 Small flange size model available.
 Small flange size model available.  Two sensors can be  Appropriate sensor for for best accuracy  USP<645> monitoring
 Two sensors can be
cy.
 8 languages
digitalYEWFLO ADMAG AXF ADMAG AXR connected. your application connected.  8 languages

Vortex Flowmeter Magnetic Flowmeter 2-wire Magnetic Flowmeter EJXC40A


Digital Remote Sensor
Liq Liq Liq
Turbidity Analyzers Chlorine Analyzers Dissolved Oxygen Analyzers
Gas Liq TB750G TB400G FC400G FC500G RC400G DO402G FLXA202/FLXA21 DO70G/DO30G
Stm Right Angle Scattered Scattered-Light Free Available Chlorine Free Available Chlorine Residual Chlorine 4-Wire Dissolved 2-Wire Dissolved Dissolved Oxygen
Multi-variable Reduced Light Turbidity Analyzer Turbidity Analyzer Analyzer Analyzer Analyzer Oxygen Converter Oxygen Transmitter Sensors
type bore type

 Spectral signal processing automatically op-  Built-in temperature sensor within the shed-  "Dual Frequency Excitation Method"  An extra AC power supply is not neces-
timizes the settings at all times, from imme- der bar offers the mass flow output or the realizes the stable measurement of sary. 2-wire loop powered performance
diately after power-on. temperature output. high concentration slurry fluid and allows direct connection to DCS I/O card
low conductivity fluid. possible, thus drastically reducing the ini-  Connecting two pressure sensors, master (high pressure side) and slave (low pressure DO70G
 Self-diagnostics, one step ahead of other  No installation of the temperature device is
tial cost and power consumption. side) in a remote location, with DRS dedicated communication cable to measure differen-
flowmeters, enables predictive mainte- needed for the process.  User-friendly functions; such as an
nance. electrode adhesion level diagnosis  AXR has SIL2 Safety Integrity Level (IEC tial pressure. DO30G
 Durable meter design mostly meets the
function, infra-red switches which 61508) certified. AXR is capable of SIL2  Suitable for level measurement of a tall tank. DRS cable length (maximum): 45 m
 Simultaneous analog and pulse signal out- steam flow such as water hammer, high  Non-reagent Type  Non-reagent Type  Measurement object: Measurement
can be used for setting parameters single use and SIL3 redundant use, as
puts. temperature process, etc.  Signal characterization for various tank types.  Polarographic method using rotating  Polarographic method using rotating  Long-term stable sensor of dissolved oxygen in aeration
without opening the case cover. standard.
gold electrode gold electrode tanks at sewage treatment plants.
 High-temperature and cryogenic models  Reduced bore type measures lower flow-  Display unit in mg/l, ppm, or % sat-
 User configurable measuring range  Surface scattered light method using  Reagent Type  Measuring range:
also available. rate.  Ideal for measurement of free avail-  Ideal for measurement of free avail- uration
from 0-0.2 NTU to 0-100 NTU. kaolin, formazin, or PSL  Polarographic method using rotating 0 to 25mg/l (ppm) (DO70G),
able chlorine in water supply and able chlorine in water supply and
Converter Configuration Tool
(polystyrene latex) for calibration  Temperature compensation, salt 0 to 20mg/l (ppm) (DO30G)
 Highly reliable measurement with platinum electrode
ROTAMETER EJA/EJX Series Differential EJX910A excellent linearity and repeatability.  Highly reliable measurement at wa-
distribution systems distribution systems concentration compensation and
 Type of sensor:
 Field-configurable from 0-1 to 0-3  Measuring range selectable:  Ideal for measurement of residual barometric air pressure compensa-
Variable Area Flowmeter Pressure Transmitters Multivariable Transmitter  In-line connection available ter supply and sewage systems
mg/l for two switchable output rang- 0-1/0-2/0-3 mg/l switchable or chlorine in chlorination processes of tion for best accuracy Optical DO sensor (DO70G),
PK200 FieldMate  Easy-to-clean cell  Measuring range: 0-2 to 0-2000 mg/l es 0-5/0-10 mg/l switchable water supply systems and in cooling  12 languages. Galvanic cell DO sensor (DO30G)
 Ideal for measurement of dissolved
Liq Liq Current-to-Pneumatic Converter Versatile Device Management Wizard (or degrees, unit selectable)
 Micro processor-based, intelligent
water of thermal power stations
oxygen in aeration tanks at sewage  Touch screen display.
converter  Measuring range: 0 to 10mg/l treatment plants, etc.  Two sensors can be connected.
Gas Gas
Stm Stm
MLSS Analyzer Liquid Density Meter FT-Near Infrared Analyzers
SS400G DM8 InfraSpec NR800
MLSS Analyzer Vibration Type Liquid Density Meter Fourier Transform Near Infrared Analyzers
 Complete stainless steel design.  Combined with an orifice, measures  Fully compensated mass flow: all flow
liquid, gas, and steam flow rates. factors can be automatically and dynami-  Electronic feedback system achieving high reliability  FieldMate is a field work-oriented software program for configuring,  Wide measuring range from 0-1000 mg/l to 0-20000 mg/l  Measures liquid density with high sensitivity and sta-  Continuous, multiple, and simulta-  Barcode reader provides easy oper-
 Local indication and analog output. and high performance. daily patrol, troubleshooting, and managing a wide variety of field bility neous measurement of component ation for at-line and routine analyses
cally calculated to an optimal value.  Ideal for measurement of mixed liquor suspended solids
 Available for direct mounting without devices used in production plants and test laboratories. (MLSS) in an aeration tank of activated sludge processes  Measuring range of 0.5 to 2.0 g/cm3 unaffected by concentration and property values  Reduces operating and maintenance
 Various process connections and wetted  Energy-saving design achieve economy.
three-valve manifold.  1.0% mass flow rate accuracy over 1:10 in sewage and industrial wastewater treatment facilities flow rate and viscosity (density, polymerization degree, costs by consolidation of lab and
materials.  Multi-protocol access support
flow range. octane value, etc.) of various pro- At-line Model
 Outstanding long-term stability slashes  Designed to be replacement-compatible with the  Detector is available in general-purpose, sanitary, process calibration models and on-
 Options such as Exi-version, inductive FOUNDATION™ fieldbus H1, BRAIN, HART, ISA100 Wireless™, cesses
maintenance costs.  Simultaneous dual output of 4 to 20 mA former model 5502. PROFIBUS, Modbus and flameproof types site hands-on training
alarms, pulse output, etc.  Measurement of trace water con-
and pulse signals for total flow, flow rate,
 Easy to operate…..one side access.  FieldMate Lite, a trial version of FieldMate, is available for download. tent available
or alarm status.
http://www.yokogawa.com/fieldmate/
Note: Liq , Gas , and Stm symbols indicate applicable process fluid types (liquid, gas, steam). On-line Model
YOKOGAWA ELECTRIC CORPORATION http://www.yokogawa.com
World Headquarters Represented by:
9-32, Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, JAPAN

YOKOGAWA CORPORATION OF AMERICA http://www.yokogawa.com/us/


YOKOGAWA EUROPE B.V. http://www.yokogawa.com/eu/
YOKOGAWA ENGINEERING ASIA PTE. LTD. http://www.yokogawa.com/sg/
YOKOGAWA CHINA CO., LTD. http://www.yokogawa.com/cn/
YOKOGAWA MIDDLE EAST & AFRICA B.S.C.(c) http://www.yokogawa.com/bh/

Subject to change without notice. [Ed:12/b] Printed in Japan, 706(KP)


All Rights Reserved, Copyright © 2001, Yokogawa Electric Corporation.

You might also like