NOTES

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED

3623
OTHERWISE (U.N.O)
2. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH
RELEVANT ARCHITECTURAL, HVAC, PLUMBING,
5 ELECTRICAL INSTALLATION DRAWINGS AND DETAILS
3. CONCRETE MIX TO BE VIBRATED AROUND STEEL

1724
REINFORCEMENT AND MUST ATTAIN MINIMUM CUBE

BEAM 17 (225x350)

BEAM 17 (225x350)

BEAM 17 (225x350)

BEAM 17 (225x350)
(C2) BEAM 8 (300x350) (C2) (C2) BEAM 8 (300x350) (C2)
4A STRENGTH OF 30 N/MM2 AT 28 DAYS EXCEPT WHERE
SPECIFIED OTHERWISE.

2902
4. CASTING OF CONCRETE SHALL NOT BE CARRIED OUT
UNTIL THE LAYING AND FIXING OF ALL STEEL

BEAM 16 (750x350)
595 BEAM 7 (750x350) REINFORCEMENT, FORM-WORK MUST HAVE BEEN
(C3) (C3) (C4) (C3) (C3) (C4) (C4)
4
CHECKED AND CERTIFIED CORRECT IN WRITING BY
BEAM 10 (750x350)

BEAM 10 (750x350)
THE ENGINEERS.

2390
5. CONCRETE, STEEL REINFORCING BARS AND OTHER
BEAM 6 (225x350) MATERIALS MUST BE TESTED AS MAY BE SPECIFIED
3C (C5) (C5)
BY THE ENGINEERS OR AS CONTAINED IN THE BILLS

780
BEAM 5 (750x350) BEAM 5 (750x350)
BEAM 12 (750x400) OF QUANTITIES AND SPECIFICATIONS. RESULTS OF

BEAM 12 (750x400)
SUCH TESTS ARE TO BE FORWARDED TO THE

BEAM 18 (225x350)

BEAM 18 (225x350)

BEAM 18 (225x350)
3B
STAIR ENGINEERS IMMEDIATELY THEY ARE CARRIED OUT.
OPENING

3720
6. STEEL REINFORCEMENTS NEAR THE TOP OF SLAB
(I.E TOP STEEL) ARE TO BE MAINTAINED IN THEIR
3A CORRECT POSITIONS WITH THE AID OF 12 MM DIA.

29744
. STEEL CHAIRS AT POSITIONS NOT EXCEEDING 1M

635
(C6) BEAM 4 (750x350) (C7) (C8) (C8) (C7) (C6) APART BOTH WAYS.
3
7. 75 mm NOMINAL COVER TO ALL REINFORCEMENTS IN
FOUNDATION.
8. 20 mm NOMINAL COVER TO ALL REINFORCEMENTS AT
BEAM 13 (635x350)

BEAM 14 (750x350)

BEAM 14 (750x350)

BEAM 13 (635x350)
TOP OF FLOOR SLAB.
9. 25 mm NOMINAL COVER TO ALL REINFORCEMENTS AT

6460
BOTTOM OF FLOOR SLAB.

1 3
10. BENDING SCHEDULES COMPLIES WITH BS 4466
A A
- - (BAR SHAPE).
11. ALL DIMENSIONS ARE IN ACCORDANCE WITH
BS 8666 - 2005.
(C6) BEAM 3 (750x350) (C9) (C7) (C7) (C9) (C6)
2 12. REINFORCEMENTS TO BE CALLED UP THUS

802
1082
30 T 12 01 150 T/B
BEAM 12 (750x400)

BEAM 12 (750x400)
NO. OF TYPE OF BAR BAR SPACING

3605
BARS BARS DIA. MARK

STAIR
OPENING T FOR TOP & B FOR BOTTOM
1B B B

BEAM 15 (750x350)

BEAM 15 (750x350)

750
- -
BEAM 2 (750x350) BEAM 2 (750x350)
BEAM 10 (750x350)

BEAM 10 (750x350)
1A BM 19(230x350) BM 19(230x350)

3155
C15,(230x230) C15,(230x230)

(C10) (C10) (C4) (C11) (C11) (C4) (C10) (C10)


1
BEAM 1 (750x350) BEAM 1 (750x350)

A1 A A2 A3 B C C1 C2 D D1 D2 D3 E E1 E2 E3 E4 F G G1 G2 H H1

GA OF 2ND SLAB LAYOUT


DETAILS OF OPENINGS FOR SERVICES TO BE CONFIRMED ON 1ST FLR. SLAB G.A

A3 C D E
175

1325 635 285 11 RIBS @ 450 C/C 285 750 138 16 RIBS @ 450 C/C 137 750 225 12 RIBS @ 450 C/C 225 750 137 RIBS @ 450 C/C

1585 5945 7900 6275 3679

Section: A - A
SCALE 1:50
D E
175

750 1062 3400 1063 750

6275

Section: B - B
SCALE 1:50
PREPARED BY CLIENT PROJECT BUILDING NO
AD RE-ISSUED FOR CONSTRUCTION 03/08/16 MA EN
AD RE-ISSUED FOR CONSTRUCTION 12/07/16 MA EN
AD RE-ISSUED FOR CONSTRUCTION 04/07/16 MA EN DRAWING SCALE

G.A of Second Floor Slab PROPOSED CASTING SEQUENCE FOR TYPICAL 1:100
WB ISSUED FOR CONSTRUCTION 22/09/15 EN
FLOOR U.N.O
NO. BY DESCRIPTION DATE CHK'D APP. NO. BY DESCRIPTION DATE CHK'D APP. 25,Ologun Agbaje Street,Off Adeola Odeku Street,
DRAWING NO. REV
Victoria Island, Lagos, Nigeria S.1.1.5