RainFlo Above Ground Tank System

# Description Qty.
Rain Filter: Leaf Eater Advance 3" with 3"
1 PVC Pipe to Tank Inlet 1

2
4" Multi-Tite Gasket, cut 5" Hole for
2
NOTE #1: Pump control and pump start box should be located within
Installation
close proximity to the tank and each other. See wiring diagram for
Graf Calming Inlet prevents disturbance
3
of sediment and on bottom of tank
1 correct wiring of pump start box and pump control.
Bulkhead Fitting, 2" Drain at Bottom and
4 1-1/2" at top (Typical) 2
RainFlo MHP75A 3/4 HP Automatic Pump, Gutter and downspout (typical)
5 Available with Optional Pump Cover 1

6 1-1/4" Suction Hose 1


NOTE #2: Pump plumbing should be run with schedule
7 Graf 1-1/4" Stainless Steel Floating Extractor 1
40 or better with thread by slip adapters at pump outlet,
8 Power Supply 115vac 1 pump control and bulkhead fittings. A union is advisable 1.
9 Tank Access Lid with Vent 1 for easy removal.
10 Compacted soil, gravel or concrete
9.
11 RainFlo PC115 Pump Controller 1 4.
1" Schedule 40 PVC Pipe and Adapters (Not
12 Supplied) 2.
13 115vac Power Supply (by others) 1 2.
14 Pump Discharge to Irrigation or Other Use 1 2200

15 Graf Overflow Siphon 1 17.


15. 2000
Tank Overflow, 4" PVC Sewer and Drain
16 (Not Supplied)
7.
17 First Flush Filter 1
NOTE #4: Pump should me located 1800

in a protected area or under a pump 1600


NOTE #3: Tank overflow should be run such that water cover. Use poly hose barb and hose
runoff does not erode area around tank. Overflow pipe clamps for connection of suction 1400

size should be larger than inlet pipe size. hose and floating extractor at 6.
1200
bulkhead fitting installed in tank
16.
NOTE #5: Tank must be placed on side wall. 1000
1" MPT Outlet
level surface. Compacted soil,
800
gravel or concrete is best. Locate 12.
as close to inlet of gutter system as NOTE #6: Fasten the calming inlet 600 4.
possible. (number 3) to PVC pipe using 2 14.
400 RainMaster

8.
stainless steel screws to prevent it
NOTE #7: Above ground polyethylene tanks can be from disconnection from pipe 200
5.
modified by adding bulkhead fittings and multi-tite 3.
gaskets where necessary. Use a hole saw of the correct 10.
1" FPT Inlet
size for the fitting being installed.
USER'S Responsibly
Rainwater supplied by RainHarvest Systems is NON-Potable water. Warning do not drink water supplied from
RainHarvest Systems rainwater systems and related equipment. We will be happy to offer suggestions on the use of NOTE: This drawing is for illustrative purposes only. Actual systems
our various products either by way of printed material or through direct contact with RainHarvest Systems team and designs may vary. Always check with local building codes as they
members. However, since we have no control over the use of our products once they are shipped, NO WARRANTY will apply.Electrical work to be performed by licensed professional.
WEATHER OF MERCHANTABILITY, FITNESS FOR PURPOSE, OR OTHERWISE is made beyond the repair, Points of use shall be labeled as: "Non Potable water, Do Not Drink!
replacement, or refund of purchase price at the sole discretion of RainHarvest Systems. Users shall determine the NOTE: This drawing is for illustrative purposes only. Actual systems CHK BY: APP BY: DRAWN BY QUOTE NO. SH.#
suitability of the product for the intended application before using, and the users assume all risk and liability
whatsoever in connection therewith, regardless of any team members suggestions or statements as to the application and designs may vary. Always check with local building codes as they CMG . 1 OF 1
or construction. In no event of the purchase price of the product. Consult local building codes for the system use.
will apply.Electrical work to be performed by licensed professional. RainFlo Above Ground Rainwater
Points of use shall be labeled as: "Non Potable water, Do Not Drink! Collection System with External Pump
RainHarvest Systems LLC.
6075 Parkway North Drive Suite D
Cumming, GA 30040
Tel: 770-889-2533 Fax: 770-889-2577