You are on page 1of 6

www.hilti.com Profis Anchor 2.7.

5
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 7/11/2017
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-HY 200-R + HIT-Z-R M10
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef,opti = 87 mm (hef,limit = 95 mm)
Material: A4
Evaluation Service Report: ETA 12/0028
Issued I Valid: 30/5/2017 | -
Proof: SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation: eb = 0 mm (no stand-off); t = 8 mm
Anchor plate: lx x ly x t = 150 mm x 150 mm x 8 mm; (Recommended plate thickness: not calculated
Profile: no profile
Base material: uncracked concrete, C25/30, fc,cyl = 25.00 N/mm2; h = 125 mm, Temp. short/long: 30/30 °C
Installation: diamond cored hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.5
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 7/11/2017
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads Compression
1 2
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.000 3.375 0.000 3.375
2 0.000 3.375 0.000 3.375 x
3 19.979 3.375 0.000 3.375
4 19.979 3.375 0.000 3.375

max. concrete compressive strain: 0.60 [‰] 3 4


max. concrete compressive stress: 17.96 [N/mm2] Tension
resulting tension force in (x/y)=(0/-40): 39.958 [kN]
resulting compression force in (x/y)=(0/65): 39.958 [kN]

3 Tension load SOFA (fib (07/2011), section 16.2.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 19.979 25.333 79 OK
Combined pullout-concrete cone failure** 39.958 43.005 93 OK
Concrete Breakout Strength** 39.958 41.154 98 OK
Splitting failure** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
38.000 1.500 25.333 19.979

3.2 Combined pullout-concrete cone failure


Ap,N [mm2] A0p,N [mm2] y A,Np
2
t Rk,ucr,25 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm]
50400 32400 1.556 22.00 180 90 ∞
2 0
hef,Helix [mm] yc t Rk,ucr [N/mm ] max t Rk,ucr [N/mm2] y g,Np y g,Np
60 1.000 22.00 13.56 1.000 1.000
ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np
0 1.000 0 1.000 1.000 1.000
N0Rk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NSd [kN]
41.469 64.507 1.500 43.005 39.958

3.3 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm]
94221 68121 1.383 131 261
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 1.000 1.000
k1 N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
11.000 44.632 1.500 41.154 39.958

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.5
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 7/11/2017
E-Mail:

4 Shear load SOFA (fib (07/2011), section 16.2.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 3.375 18.400 19 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 13.500 110.691 13 OK
Concrete edge failure in direction ** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
23.000 1.250 18.400 3.375

4.2 Pryout Strength (Concrete Breakout Strength controls)


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm] k4
126711 68121 1.860 131 261 2.000
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 1.000 1.000
N0Rk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
44.632 1.500 110.691 13.500

5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.789 0.183 2.000 66 OK
concrete 0.971 0.122 1.500 100 OK

baN + baV <= 1

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 14.799 [kN] dN = 0.217 [mm]
VSk = 2.500 [kN] dV = 0.150 [mm]
dNV = 0.263 [mm]
Long term loading:
NSk = 14.799 [kN] dN = 0.487 [mm]
VSk = 2.500 [kN] dV = 0.200 [mm]
dNV = 0.527 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.5
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 7/11/2017
E-Mail:

7 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility! 
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Characteristic bond resistances depend on short- and long-term temperatures.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
• The compliance with current standards (e.g. EC3) is the responsibility of the user
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.5
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 7/11/2017
E-Mail:

8 Installation data
Anchor plate, steel: - Anchor type and diameter: HIT-HY 200-R + HIT-Z-R M10
Profile: no profile Installation torque: 0.025 kNm
Hole diameter in the fixture: df = 12 mm Hole diameter in the base material: 12 mm
Plate thickness (input): 8 mm Hole depth in the base material: 87 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 120 mm
Drilling method: Core drilled
Cleaning: Flush and blow the hole

8.1 Recommended accessories

Drilling Cleaning Setting


• Diamond core rig, as per approval • Flushing and blowing accessories • Dispenser including cassette and mixer
• Seismic/Filling set
• Torque wrench
y

75 75

25
1 2

75
90

x
75

3 4
35

25 100 25

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -50 50 - - - -
2 50 50 - - - -
3 -50 -40 - - - -
4 50 -40 - - - -

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.5
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 7/11/2017
E-Mail:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like