You are on page 1of 1

1/13/2017 Selecting A Flowmeter

Your Source for Process Measurement & Control

Flowmeter Selection Guide

Technical Reference Selection Guide

← Back To Flow Control 

Typical Required
Flowmeter Pressure Viscosity Relative
Recommended Service Rangeability Accuracy, Upstream pipe,
element Loss effect Cost
percent diameters

Clean, dirty liquids; some ±2 to ±4 of
Orifice 4 to 1 Medium 10 to 30 High Low
slurries full scale2

Low to ±0.5 to ±2 of
Wedge Slurries and Viscous liquids 3 to 1 10 to 30 Low High
medium full scale

Clean, dirty and viscous
Venturi tube 4 to 1 Low ±1 of full scale 5 to 20 High Medium
liquids; some slurries

±1 to ±2 of
Flow nozzle Clean and dirty liquids 4 to 1 Medium 10 to 30 High Medium
full scale

±3 to ±5 of
Pitot tube Clean liquids 3 to 1 Very low 20 to 30 Low Low
full scale

Clean, dirty liquids; some ±5 to ±10 of
Elbow meter 3 to 1 Very low 30 Low Low
slurries full scale

Clean, dirty viscous liquids; ±1 to ±5 of
Target meter 10 to 1 Medium 10 to 30 Medium Medium
some slurries full scale

±1 to ±10 of
Variable area Clean, dirty viscous liquids 10 to 1 Medium None Medium Low
full scale

Positive
Displacement
Clean, viscous liquids 10 to 1 High ±0.5 of rate3 None High Medium

Turbine Clean, viscous liquids 20 to 1 High ±0.25 of rate 5 to 10 High High

Vortex Clean, dirty liquids 10 to 1 Medium ±1 of rate 10 to 20 Medium High

Clean, dirty viscous
Electromagnetic conductive liquids and 40 to 1 None ±0.5 of rate 5 None High
slurries

Ultrasonic Dirty, viscous liquids and
10 to 1 None ±5 of full scale 5 to 30 None High
(Doppler) slurries

Ultrasonic(Time­ ±1 to ±5 of
Clean, viscous liquids 20 to 1 None 5 to 30 None High
of­travel) full scale

Clean, dirty viscous liquids;
Mass(Coriolis) 10 to 1 Low ±0.4 of rate None None High
some slurries

Clean, dirty viscous liquids;
Mass (Thermal) 10 to 1 Low ±1 of full scale None None High
some slurries

±2 to ±5 of
Weir (V­notch) Clean, dirty liquids 100 to 1 Very low None Very Low Medium
full scale

±2 to ±5 of
Flume (Parshall) Clean, dirty liquids 50 to 1 Very low None Very low Medium
full scale

← Back To Flow Control 

© Copyright 2003­2017 OMEGA Engineering is a subsidiary of Spectris plc 
OMEGA privacy statement |  Terms and Conditions |  Export Control Policy

­ | 79

http://www.omega.com/techref/table1.html 1/1