TEST REPORT SABS High Voltage Laboratory Report No. HV/105640 Page 1 of 5 Client + Diamond Power infrastructure Limited Essen House, 5/12,B.|.D.C, Gorwa, Vadodara - 390016 Manufacturer : Diamond Power infrastructure Limited, India ‘Apparatus tested ACSR Bersimis conductor (Al 42/4.57 +St 7/2.54 mm) Voltage rating 2765 kV Configuration type + Quad bundle Bundle Spacing 2457 mm Sample Identification + No Identifeation Tests performed + Dry RIV and Corona tests. ‘Tests have been carried out in accordance with the client's instructions: Test procedures and test parameters were based on: Radio Interference characteristics of overhead power lines and high-voltage: C.LS.P.R. Publication 18-2: 2010 equipment Part 2: Methods of measurement and procedure for determining limits Clause 4.6.13 Test procedure Date of tests +: 24 May 2011 Conclusion + The results are shown in section 4 of this report This report consists of the following pages: Report forms 5 Ah hide /den Heover é tng ee ay Lobe NETFA oe. ES GW Bourn (Technical Signatory) Specialist: High Voltage Laboratory NETFA Olifantsfontein, 10 June 2011, 1 Apollo Road, Olifantsforitein, P.O.Box 144, Olifantsfontoin, Tol: +27 (011) 238 2300, Fax: +27 (014) 238 2363 ‘The est wor lating oh report was peroned by SABS Commercial (Py) Lid. Th rept ais el resus teeny othe spec pat) ere he. hay ra ingly SASS deport he sual uclr fener ate ans aweeiorans eee we ASA ‘ere re one to any snr hom tutus tt Sas ned cr Bed te oats ie son ARES == ‘hs rpm nyt priced arcana Th stant of pa anh cons ans Ce oy cntcing eased CaS» ‘South African Bureau of Standards TEST REPORT No. HV/105640 Page 2 of 5 1 Test method ‘The four Bersimis conductors comprising the quad bundle were cut to 6m lengths and provided with crimped dead-ends. The conductors were then attached to end plates with 457mm spacing between conductors. ‘The bundle conductor was provided with discharge-free terminations and suspended at a height of 15 m (geometric mean centre to grounc) Photographs of the suspended test sample and environment are shown in photographs 1 and 2 below. Photograph 1 Test object suspended at 15m, Photograph 2 Test object viewed from below South African Bureau of Standards ‘TEST REPORT No, HV/105640 age 3018 2 Measuring equipment The following equipment was used for the measurements: Marcondmodet | A85 numver MPRIER OA] carey a TEST i peak votre’ —— [Pano Type sae5 861 | Nort $108 Sd ioe Hon Fenowonr vis 7400 sosenses | oan Hos Shoe CGallbraton of the above equipment ls kaceable to national standards. 2.1 Tolerance on measurements AC voltage 2% RIV 5% 3 Test conditions The tests were conducted at the National Electrical Test Facility of the South African Bureau of Standards. Test laboratory altitude: 1540 m ‘Sample condition: The sample arrived wrapped in a protective cover which was removed after the sample was strung up for testing. 4 Results 41. RIV and visible corona measurements, Table 1 on the next page shaws the sequence of voltage application and the results of RIV and visible corona tests. The plot of all recorded RIV values is shown in Figure 4 2a May 71 RIV | 80 70 60 tm 50 3 40 30 a 20 * 10 0 400-420-440, 460480 500-520 540880 KV (measures) ‘SARS /NETFA Figure 1, Plot of RIV against applied voltage Sample ACSR Bersimis conductor (Al 42/4 57 +St 7/2.54 mm) Manufacturer: Diamond Power Infrastructure Limited South African Bureau of Standards TEST REPORT No, HV/105640 Page 4of5 Pressure 85_|kPa Temperature 7 |e Humidity 7.09 |g/m* Height (GMR) 15__|m Atmospheric correction factor: 0.87 Specified Test voltage Up 510 |kv Voltage e RIV 3 iat measured | corrected” | § (Mnz; 3000) E | increasing votage | decreasing voltage kV kV sel a ww. aB wv 106% 540 667 5 | 80 | 10000 | 80 | 10000 100% 510 630 58 | 704 | 58 | 704 106% 540 667 1 80 10000 530 654 69 | 2818 520 642 66 1995 515 636 64 | 1585 510 630 58 794 505, 623 54 501 500 6i7 52 | 398 490 605 36 63 450 556 30 32 425 525 27 22 400 494 26 18 0 o 25 | 18 oO oO 25 18 ° 0 25 | 18 oO oO 25 18 oO oO 25 18 ‘c Inception Extinction £ é reading | mean| corrected reading mean | corrected 3 kv. kv kV. kV. kV. kv g 517 512 g 514 515 636 511 512 | 632 oO 515 513 “oprrected to 20°C, 101 3kPa and 1 g/m’ humidity in accordance with IS 731-1971 Appendix A Table 1. ‘Sequence of voltage application and measurements of RIV and corona ‘South African Bureau of Standards TEST REPORT No. HV/105640 Page 5 of § Ina further test, the visible corona inception and extinction voltages (as viewed through a corona camera) were determined 3 times. The photographs below show the corona at the highest uncorrected voltage and at the required uncorrected corona-free voltage. bor LO Meurer lire) 44.1 Summary of Corona tests Parameter Measured Corrected™ Corona inception (mean of )[__ 515 KV. 636 KV Corona extinction (mean of 3) _512__—iKV 632K “ToS. 731-1971 Ea. 38) 441.2 Summary of RIV tests ‘Applied voltage RV Gy) Measured [ corrected” | frequency measured ‘510 KV 630_KV 7.0__MHz | 58 oB 798 “eis 731-1971 Ed 38)

You might also like