Pump Data Sheet - Xylem

Multiwira Mitra Perkasa, PT

Pump: Search Criteria:


Size: 125-95 Flow: 170.25 m³/hr Head: 110 m
Type: GSC Speed: 2970 rpm
Fluid:
Synch speed: 3000 rpm Dia: 278 mm
Water Temperature: 15.6 °C
Curve: Impeller:
SG: 1 Vapor pressure: 0.01773 bar a
Specific Speeds: nq: --- Viscosity: 1.104 cP Atm pressure: 1.014 bar a
S: ---
NPSHa: ---
Dimensions: Suction: ---
Discharge: --- Motor:
Standard: IEC Size: 90 kW
Pump Limits:
Enclosure: TEFC Speed: 3000
Temperature: --- Power: --- Frame: 280S
Pressure: --- Eye area: --- Sizing criteria: Design Point
Sphere size: ---

71 75
---- Data Point ---- 284 mm 77150% Rated Capacity
79
Flow: 170 m³/hr 278 mm 80
Head: 110 m 80
79.7 79
Eff: 66.6% 100 77
Power: 75.8 kW
75
NPSHr: 3.88 m 72
255 mm
---- Design Curve ---- 55 kW 71
Shutoff head: 108 m 75
75 kW 150 kW
Shutoff dP: 10.6 bar 75
77
Min flow: ---
Head - m

77
BEP: 79.7% @ 324 m³/hr
75
NOL power: 72 111 kW
132 kW @ 442 m³/hr
50 90 kW
-- Max Curve --
Max power:
146 kW @ 446 m³/hr

25

0
50 100 150 200 250 300 350 400 450
15
NPSHr - m

10

0
50 100 150 200 250 300 350 400 450
m³/hr
Performance Evaluation:
Flow Speed Head Efficiency Power NPSHr
m³/hr rpm m % kW m
204 2970 109 72.7 83.4 4.08
170 2970 110 66.5 75.8 3.88
136 2970 111 58.1 69.1 3.78
102 2970 --- --- --- ---
68.1 2970 --- --- --- ---

Selected from catalog: greaterasia.lowara.50 Vers: .1