You are on page 1of 4

Company name:

Created by: Jockey Pump


Phone: Cap: 25 USGPM; Head: 125 M

Date: 7/20/2017

96517054 CR 5-24 50 Hz
H CR 5-24, 3*400 V, 50Hz eta
[m] [%]
Q = 25 US gpm
H = 125 m
n = 99 % (49.3Hz)
Pumped liquid = Drinking water
Liquid temperature during operation = 293 K
Density = 998.2 kg/m³
180

100 %
99 %
160

140

120

100 100

80 80

60 60

40 40

20 20

Eff pump = 64.3 %


Eff pump & mtr = 54.9 %
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Q [US gpm]
P NPSH
[kW] [m]

4 P1 8

P2
3 6

2 4

1 2

P1 = 3.519 kW
P2 = 3 kW
NPSH = 1.56 m
0 0

Printed from Grundfos Product Center [2017.04.034] 1/2


Company name:
Created by:
Phone:

Date: 7/20/2017

96517054 CR 5-24 50 Hz

134

220
372
899

G 1/2 19 x 24.5
ø100
ø140
ø89
75

20

100 ø35 4 x ø13.5


141 180
250 220

Note! All units are in [mm] unless otherwise stated.


Disclaimer: This simplified dimensional drawing does not show all details.

Printed from Grundfos Product Center [2017.04.034] 2/2


JP

Model
Jockey Pump Controller
Full voltage across the line starter
Solid State Controls with Digital
Standard Features: Operator Interface
• Solid state controls with digital iPD+
operator interface
• All adjustments on door front
• Visual indicators
• Manual motor run
• Automatic motor run
• System pressure
• Automatic mode
• Off mode
• Motor overload
• Pump start counter
• Elapsed time meter (hours / non-resettable)
• Timers
• Minimum run period timer
• Sequential start timer
• Operators
• OFF-AUTO pushbutton
• Start and stop pushbuttons
• NEMA 2 enclosure
• Pressure transducer
• Fuseless magnetic motor starter

The model JP jockey pump controllers are specifically


designed to control jockey pumps in order to
maintain the desired water pressure in fire pump
serviced systems. A jockey pump installation prevents
unnecessary starting of the fire pump due to small leaks
in the sprinkler system piping.
The standard power circuit consists of a horsepower
The model JP jockey pump controller is supplied with the rated disconnect switch, a thermo-magnetic motor
front door mounted, solid state controls with digital iPD+ protector and a motor contactor for across the line
operator interface. The iPD+ allows the user to set and adjust full voltage starting. Consult factory for other types of
all parameters required such as start and stop pressures, motor protection or starting methods available.
ON or OFF timers and units of measure (psi, bar, kPA, feet of
head, meter of head) without having to open the controller Individual models are specific to the voltage available
door. The iPD+ also continuously displays the system on site:
pressure and the start and stop pressure settings. LED visual • JP1: 120 V / Hp (kW) / single phase / 60Hz
indications include manual motor run, automatic motor • JP2: 220 to 240 V / Hp (kW) / single phase / 50 or 60Hz
run, system pressure above stop pressure setting, system • JP3: 208 to 600 V / Hp (kW) / three phase / 50 or 60Hz
pressure in-between start and stop pressure setting and SEISMIC COMPLIANT

system pressure below start pressure setting.


ICC-ES AC156
IBC 2015
CBC 2013
JP
Model
7

Operator Interface

2
1

5
4

9 8

6
6 - OFF-AUTO position pushbutton and visual
indication (LED)
7 - Horsepower rated door interlocked rotary
type disconnect switch
1 - High luminosity four digit digital display 8 - Fuseless magnetic motor starter with
2 - System status diagnostic LED’s for: thermo-magnetic motor protector and
i. Green: system pressure at or above cut-out horsepower rated contactor
value 9 - Pressure transducer with 0-600psi
ii. Yellow: system pressure between cut-in range and stainless steel construction
and cut-out
iii. Red: system pressure at or below cut-in value
3 - Motor run LEDs (manual start or automatic start)
4 - Start and stop pushbuttons
5 - Navigation keypad
HOW TO ORDER: JPx - V / HP / Ph / Hz
Ex.: JP3 - / / 3 / 50

JP-BRO-002/E Rev.11 August 2016 Printed in Canada


tornatech.com
*The information contained in this brochure is subject to change without notice.