Company name:

Created by: Jockey Pump


Phone: Cap: 25 USGPM; Head: 125 M

Date: 7/20/2017

96517054 CR 5-24 50 Hz
H CR 5-24, 3*400 V, 50Hz eta
[m] [%]
Q = 25 US gpm
H = 125 m
n = 99 % (49.3Hz)
Pumped liquid = Drinking water
Liquid temperature during operation = 293 K
Density = 998.2 kg/m³
180

100 %
99 %
160

140

120

100 100

80 80

60 60

40 40

20 20

Eff pump = 64.3 %


Eff pump & mtr = 54.9 %
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Q [US gpm]
P NPSH
[kW] [m]

4 P1 8

P2
3 6

2 4

1 2

P1 = 3.519 kW
P2 = 3 kW
NPSH = 1.56 m
0 0

Printed from Grundfos Product Center [2017.04.034] 1/2


Company name:
Created by:
Phone:

Date: 7/20/2017

96517054 CR 5-24 50 Hz

134

220
372
899

G 1/2 19 x 24.5
ø100
ø140
ø89
75

20

100 ø35 4 x ø13.5


141 180
250 220

Note! All units are in [mm] unless otherwise stated.


Disclaimer: This simplified dimensional drawing does not show all details.