KR230U

Engine type 6090HFS85


Alternator type AT01512T
Canopy type M3227
Performance class G3

GENERAL CHARACTERISTICS
Frequency (Hz) 60
Voltage (V) 480/277
Max power ESP (kVA) 282
Max power ESP (kWe) 226
Max power PRP (kVA) 256
Max power PRP (kWe) 205
Intensity (A) 339
Standard control panel APM303
Optional control panel DEC4000

SMALL AUTONOMY DIMENSIONS


DESCRIPTIVE Length (mm). 4332
Connection terminal box rental type Width (mm). 1361
Containment fuel tank and large autonomy Height (mm). 2431
Forks and frame protection pads Dry weight (kg). 4090
Battery isolating switch
Tank capacity (L). 1083
Heavy duty air filter with interchangeable cartridge
Access door to the radiator Autonomy @ 75% of load (h) N/A
Autonomy @ 50% of load (h) N/A

POWER DEFINITION
SOUND LEVELS
PRP : Prime Power is available for an unlimited number of annual
operating hours in variable load applications, in accordance with Acoustic pressure level @1m in dB(A) 0 (0.7)
ISO 8528-1. ESP : The standby power rating is applicable for
supplying emergency power in variable load applications in Acoustic pressure level @7m in dB(A) N/A
accordance with ISO 8528-1. Overload is not allowed.

TERM OF USE
According to the standard, the nominal power assigned by the genset
is given for 25°C Air Intlet Temperature, of a barometric pressure of
100 kPA (100 m A.S.L), and 30 % relative humidity. For particular
conditions in your installation, refer to the derating table.

ASSOCIATED UNCERTAINTY
For the generating sets used indoor, where the acoustic pressure
levels depends on the installation conditions, it is not possible to
specify the ambient noise level in the exploitation and maintenance
instructions . You will also find in our exploitation and maintenance
instructions a warning concerning the air noise dangers and the need
to implement appropriated preventive measures.

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.
GBD5-08021 (KR230U) 02/16
KR230U
ENGINE SPECIFICATIONS

GENERAL ENGINE DATA EXHAUST


Engine model JOHN DEERE Exhaust gas temperature @ ESP 60Hz (°C) 477
Engine type 6090HFS85 Exhaust gas flow @ ESP 60Hz (L/s) 838
Air inlet Turbo Max. exhaust back pressure (mm H2O) 765
Cylinders arrangement L
Number of cylinders 6
FUEL
Displacement (L) 8.98
Consumption @ 110% load (L/h) 56.9
Charge Air coolant Air/Water DC
Consumption @ 100% load (L/h) 58.8
Bore (mm) x Stroke (mm) 118.4 x 136
Consumption @ 75% load (L/h) 44.7
Compression ratio 16 : 1
Speed (RPM) Consumption @ 50% load (L/h) 32.4
1800
Pistons speed (m/s) 8.16 Maximum fuel pump flow (L/h) N/A

Maximum stand-by power at rated


258.4
RPM (kW) OIL
Frequency regulation, steady state (%) +/- 0.5% Oil capacity (L) 31
BMEP (bar) 17.5 Min. oil pressure (bar) 1.9
Governor type Electronic Max. oil pressure (bar) 2.4
Oil consumption 100% load (L/h) N/A
COOLING SYSTEM Oil sump capacity (L) N/A
Radiator & Engine capacity (L) N/A
Max water temperature (°C) 110 HEAT BALANCE
Outlet water temperature (°C) N/A Heat rejection to exhaust (kW) 177
Fan power (kW) N/A Radiated heat to ambient (kW) 26
Fan air flow w/o restriction (m3/s) N/A 86.1
Heat rejection to coolant (kW)
Available restriction on air flow (mm
N/A
H2O)
Type of coolant Glycol-Ethylene AIR INTAKE
Thermostat modulating range HT (°C) 85-95 Max. intake restriction (mm H2O) 637
Intake air flow (L/s) 352

EMISSIONS
Emission PM (g/kWh) N/A
Emission CO (g/kWh) N/A
Emission HC+NOx (g/kWh) N/A
Emission HC (g/kWh) N/A

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.
GBD5-08021 (KR230U) 02/16
KR230U
ALTERNATOR SPECIFICATIONS

GENERAL DATA OTHER DATA


Alternator type AT01512T Continuous Nominal Rating 40°C (kVA) 300
Number of Phase Three phase Standby Rating 27°C (kVA) 337
Power factor (Cos Phi) 0.8 Efficiencies 100% of load (%) 92.8
Altitude (m) 0 to 1000 Air flow (m3/s) 0.51
Overspeed (rpm) 2250 Short circuit ratio (Kcc) 0.413
Number of pole 4 Direct axis synchro reactance unsaturated (Xd) (%) 327
Capacity for maintaining short circuit at Yes Quadrature-axis synchro reactance unsaturated (Xq)
3 ln for 10 s 166
(%)
Insulation class H Open circuit time constant (T'do) (ms) 2105
T° class (H/125°), continuous 40°C H / 125°K
Direct axis transient reactance saturated (X'd) (%) 15.5
T° class, standby 27°C H / 163°K
Short circuit transient time constant (T'd) (ms) 100
AVR Regulation Yes Direct axis subtransient reactance saturated (X''d) (%) 9.3
Total Harmonic Distortion in no-load Subtransient time constant (T"d) (ms) 10
<2.5
DHT (%) Quadrature-axis subtransient reactance saturated
Total Harmonic Distortion, on load DHT 11.5
<2.5 (X"q) (%)
(%)
Subtransient time constant (T"q) (ms) 10
Wave form : NEMA=TIF <50
Zero sequence reactance unsaturated (Xo) (%) 0.6
Wave form : CEI=FHT <2
Negative sequence reactance saturated (X2) (%) 10.42
Number of bearing 1
Armature time constant (Ta) (ms) 15
Coupling Direct
Voltage regulation at established rating No load excitation current (io) (A) 1.03
0.5
(+/- %) Full load excitation current (ic) (A) 3.9
Recovery time (Delta U = 20% 500 Full load excitation voltage (uc) (V) 52.2
transient) (ms) Engine start (Delta U = 20% perm. or 50% trans.)
Protection class IP 23 599.38
(kVA)
Technology Without collar or Transient dip (4/4 load) - PF : 0.8 AR (%) 14
brush
No load losses (W) 5537.97
Heat rejection (W) 18597.4
Unbalanced load acceptance ratio (%) 100

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.
GBD5-08021 (KR230U) 02/16
KR230U
CONTROL PANEL

APM303, comprehensive and simple DEC4000, ergonomic and user-friendly

The APM303 is a versatile unit which can be operated in The highly versatile DEC4000 control unit is complex yet
manual or automatic mode. It offers the following features: accessible, thanks to the particular attention paid to
Measurements: optimising its ergonomics and ease of use. With its large
phase-to-neutral and phase-to-phase voltages, fuel level display screen, buttons and scroll wheel, it places the
(In option : active power currents, effective power, power accent on simplicity and communication.
factors, Kw/h energy meter, oil pressure and coolant
temperature levels) The DEC4000 offers the following functions:
Supervision:
Modbus RTU communication on RS485 Electrical measurements: voltmeter, frequency meter,
Reports: ammeter.
(In option : 2 configurable reports)
Safety features: Engine parameters: working hours counter, oil pressure,
Overspeed, oil pressure,coolant temperatures, minimum coolant temperature, fuel level, engine speed, battery
and maximum voltage, minimum and maximum frequency voltage.
(Maximum active power P<66kVA)
Traceability: Alarms and faults: oil pressure, coolant temperature, failure
Stack of 12 stored events to start, overspeed, alternator min./max., battery voltage
For further information, please refer to the data sheet for the min./max., emergency stop, fuel level.
APM303.
Ergonomics: wheel for navigating around the various
menus.

Communication: remote control and operation software,


USB connections, PC connection.

For more information on the product and its options, please


refer to the sales documentation.

This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.