EFFECT OF CHANNEL WIDTH

Material of construction= Titanium

Inlet pressure = 1 bar

Water temperature = 10 °C

Water flow rate = 100 kg/hr

Steam temperature = 150 °C

Steam flow rate = 100 kg/hr

Cold Stream - corresponding to water stream


Gas
Channel Pressur
Liquid flow flow
width Temperature (°C) e drop
rate (kg/hr) rate
(mm) (bar)
(kg/hr)
216 138.13 0 100 0.00164
266 137.39 0 100 0.00079
316 136.96 0 100 0.00051
356 136.64 0 100 0.00038
416 136.21 0 100 0.00026

Hot Stream - corresponding to steam stream


Gas
Channel Pressure
Liquid flow flow
width Temperature (°C) drop
rate (kg/hr) rate
(mm) (bar)
(kg/hr)
216 13.51 100 0 0.00113
266 13.83 100 0 0.00054
316 14.01 100 0 0.00034
356 14.15 100 0 0.00025
416 14.34 100 0 0.00016
Hot stream Cold stream
450 450
400 400
Channel width (mm)

Channel width (mm)


350 350
300 300
250 250
200 200
150 150
100 100
50 50
0 0
13.413.513.613.713.813.9 14 14.114.214.314.4 136 136.5 137 137.5 138 138.5
Temperature (°C) Temperature (°C)

1. EFFECT OF FLOWRATES OF BOTH FLUIDS.

Material of Construction = Titanium

Inlet pressure = 1 bar

Water inlet temperature = 10 °C

Steam inlet temperature = 150 °C

Channel width = 216 mm

Input Streams Cold Stream - corresponding to water stream


Water Steam Water to Liquid flow
Temperature Gas flow Pressure
flow rate flow rate Steam flow rate
(°C) rate (kg/hr) drop (bar)
(kg/hr) (kg/hr) rate ratio (kg/hr)
140 100 1.4 97.96 42.5 97.5 0.00174
120 100 1.2 97.96 19.4 100.6 0.00172
100 100 1 138.13 0 100 0.00164
80 100 0.8 148.86 0 80 0.00116
100 100 1 138.13 0 100 0.00164
100 80 1.25 97.98 20.16 79.84 0.00122

Input Streams Hot Stream - corresponding to steam stream


Water Steam Water to Liquid flow
Temperature Gas flow Pressure
flow rate flow rate Steam flow rate
(°C) rate (kg/hr) drop (bar)
(kg/hr) (kg/hr) rate ratio (kg/hr)
140 100 1.4 10 100 0 0.00112
120 100 1.2 10.14 100 0 0.00112
100 100 1 13.51 100 0 0.00113
80 100 0.8 100 93.6 6.4 0.00139
100 100 1 13.51 100 0 0.00113
100 80 1.25 10.02 100 0 0.00076
Cold stream Hot stream
160 160

Water flow rate (kg/hr)


Water flow rate (kg/hr)

140 140
120 120
100 100
80 80
60 60
40 40
20 20
0 0
90 100 110 120 130 140 150 160 0 20 40 60 80 100 120
Temperature (°C) Temperature (°C)

2. EFFECT OF MATERIALS OF CONSTRUCTION

Inlet pressure = 1 bar

Water inlet temperature = 10 °C

Water inlet flow rate = 120 kg/hr

Steam inlet temperature = 150 °C

Steam inlet flowrate = 100 kg/hr

Channel width = 216 mm

Cold Stream - corresponding to water stream


Material of Liquid Gas flow Pressure
Temperature
constructio flow rate rate drop
(°C)
n (kg/hr) (kg/hr) (bar)
Titanium 97.96 19.4 100.6 0.00172
Hastelloy 97.96 19.4 100.6 0.00172

Hot Stream - corresponding to steam stream


Material of Liquid Gas flow Pressure
Temperature
constructio flow rate rate drop
(°C)
n (kg/hr) (kg/hr) (bar)
Titanium 10.14 100 0 0.00112
Hastelloy 10.19 100 0 0.00112

*very minute difference in the temperature based on the material used.


4. OVERALL ENERGY REQUIREMENTS

Steam
Channel Water flow Material of Overall energy
flow rate
width (mm) rate (kg/hr) construction requirement (kW)
(kg/hr)
216 100 100 Titanium 139.4354747227
266 100 100 Titanium 67.0111337163
316 100 100 Titanium 42.9502778001
356 100 100 Titanium 31.8820899622
416 100 100 Titanium 21.4159088133

216 140 100 Titanium 169.0985790841


216 120 100 Titanium 156.5250457062
216 100 100 Titanium 139.4354747227
216 80 100 Titanium 105.9365910769
216 100 100 Titanium 139.4354747227
216 100 80 Titanium 94.8703539131

216 100 100 Titanium 156.5250457062


Hastelloy 156.5250457062
216 120 100

Channel width dependency

Overall energy in kW VS Channel width


160

140

120

100
Overall energy

80

60

40

20

0
216 266 316 356 416
Channel width
Flow rate dependency.

Overall energy in kW VS Flow rate (kg/hr)


180
160
140
120
Overall energy

100
80
60
40
20
0
140 120 100 80 100 100
Flow rate of Steam

Material dependancy

180

160

140

120

100

80

60

40

20

0
120 Hastelloy

Note: The Heat Exchanger Design Handbook has no widgets for plate heat exchangers. Hence, we are