You are on page 1of 2

Sheet # 1

Job # 1

Program: LEAP® Bridge V8i (SELECTseries 6) Designed A.K


Bentley Systems
Version: 13.00.00.68 Copyright © Bentley Systems, Inc. 2013 Date 7/8/2014
www.bentley.com Phone: 1-800-778-4277 Checked A.K
File Name: check of pier.rcp Date Jul/08/2014

Note:
Please note the analysis is based on the assumption that the cap is
infinitely rigid which results into only axial forces in the piles.

Pile Reactions, Service Load Effect @ Pile Cap Bot.


X Z Batter X Batter Z P Mxx Mzz Pile Reac.
Pile comb Ovs
mm mm degree degree kN kNm kNm kN
1 2500 -0 0 0 342 1.000 -1736.10 -299.77 407.98 907.09 #
344 1.000 -1420.72 -299.77 -2807.72 441.68 #
2 12950 -0 0 0 337 1.000 -1607.61 -299.77 -3174.15 1107.55 #
2571 1.000 -1128.06 -134.80 216.53 543.31 #

Pile Reactions, Factored Load Effect @ Pile Cap Bot.


X Z Batter X Batter Z P Mxx Mzz Pile Reac.
Pile comb Ovs
mm mm degree degree kN kNm kNm kN
1 2500 -0 0 0 6 --- -2233.50 -403.54 549.20 1169.31 #
116 --- -1397.62 -403.54 -3779.62 337.12 #
2 12950 -0 0 0 1 --- -2060.54 -403.54 -4272.90 1439.16 #
148 --- -1020.24 0.00 -0.00 510.12

Pile Reactions: Notes


# Piles are collinear and there exists an unbalanced moment in the direction perpendicular to the line of piles.
Pile reaction calculation is based on the assumption that pile cap is infinitely rigid. Load effects
on pile are calculated at CG of pile group.
Both the max. and min. pile reaction are reported for each individual pile.
Positive pile reaction represents pile subject to compression load; negative pile
reaction represents pile subject to uplift.
Coordinate system of pile layout see Geometry Tab>Footing Pile>Edit Pile.

Units: SI (Metric) Design Code: AASHTO LRFD


Sheet # 2
Job # 1

Program: LEAP® Bridge V8i (SELECTseries 6) Designed A.K


Bentley Systems
Version: 13.00.00.68 Copyright © Bentley Systems, Inc. 2013 Date 7/8/2014
www.bentley.com Phone: 1-800-778-4277 Checked A.K
File Name: check of pier.rcp Date Jul/08/2014

Pile Lateral Resistance Check X


Controlling load combination number 74
Lateral loads on all piles(kN) 676.896
Batter angle(deg) 0.000
Available lateral resistance due to batter(kN) 0.000
Direct shear resistance of all piles(kN) 6000.000
Total pile lateral resistance(kN) 6000.000
Is the lateral resistance due to batter greater than lateral load on all piles? NO
Is the total pile lateral resistance greater than the lateral load on all piles? YES

Pile Lateral Resistance Check Z


Controlling load combination number 1337
Lateral loads on all piles(kN) 481.329
Batter angle(deg) 0.000
Available lateral resistance due to batter(kN) 0.000
Direct shear resistance of all piles(kN) 6000.000
Total pile lateral resistance(kN) 6000.000
Is the lateral resistance due to batter greater than lateral load on all piles? NO
Is the total pile lateral resistance greater than the lateral load on all piles? YES

Units: SI (Metric) Design Code: AASHTO LRFD