INSTALLATION AND OPERATION GUIDE FOR

MOBERG fireplaces
Georgian series gas log system GS-18-3

For all models tested by OMNI-Test Laboratories, Inc., to ANSI Z21.60-2003/CGA 2.26-2003, Decorative
Appliance for Installation in Solid Fuel Burning Fireplaces. For model number and OMNI seal refer to
attached nameplate. Copyright Moberg Fireplaces 1-25-05

-This appliance to be installed only in a solid fuel burning fireplace with a


WARNING: If the information in working flue and constructed of noncombustible material. The minimum
this manual is not followed firebox dimensions are: 22” High x 24” Wide x 20” Deep.
-This gas appliance is designed to burn Natural Gas ONLY.
exactly, a fire or explosion may -The fireplace’s chimney must have a permanent vent opening to
result causing property damage, atmosphere of not less than 58 square inches.
personal injury or loss of life. -Solid fuels shall not be burned in a fireplace where a decorative appliance
Do not store or use gasoline or has been installed.
-Any chimney damper in the system should be in a fixed open position –or-
other flammable vapors and be of an automatic variety that has proving capabilities compatible with
liquids in the vicinity to this or any appliance gas controls.
other appliance. -A fireplace screen must be in place when appliance is operating and,
unless other provisions for combustion air are provided, the screen shall
WHAT TO DO IF YOU SMELL GAS have an opening(s) for introduction of combustion air.
• Do not try to light any appliance. -The minimum inlet supply pressure for the purpose of input adjustment is
5” W.C. The maximum inlet supply pressure is 10.5” W.C.
• Do not touch any electrical -There are many different local codes for gas-fired systems. Their
switch. installation and the provision for combustion and ventilation air must
• Do not use any phone in your conform to local codes and, or in the absence of local codes, with the
National Fuel Gas Code ANSI Z223.1/NFPA 54 or the CSA B149.1,
Building.
Natural Gas and Propane Installation Code.
• Immediately call your gas -Do not use this appliance if any part has been under water. Immediately
supplier from a neighbor’s call a qualified service technician to inspect the appliance and to replace
phone. Follow the gas supplier’s any part of the control system and any gas control which has been under
instructions. water.
-The appliance area is to be clear of combustible materials, gasoline and
• If you cannot reach your gas other flammable vapors and liquids.
supplier, call the fire department. -The appliance and its main appliance gas valves must be disconnected
from the gas supply piping system during any pressure testing of that
• Installation and service must be system at test pressures in excess of ½ psi (3.5kPa). The appliance must
performed by a qualified be isolated from the gas piping system by closing its equipment shutoff
installer, service agency or the valve during any pressure testing of the gas supply piping system at test
gas supplier. pressures equal to or less than ½ psi (3.5kPa).
-The fireplace chimney or venting system should be examined annually
and cleaned as required by a qualified agency.