790 Steam Traps 1st quarter 6/19/00 8:57 AM Page ST-13

200 Series Inverted Bucket Steam Traps


Cast Iron for Vertical Installation
For Pressures to 250 psig (17 bar)...Capacities to 20,000 lb/hr (9,072 kg/hr)
Steam Tracing Equipment

A
Steam Trapping and

Description
The most reliable steam trap known—the inverted bucket—provides efficient Connections
condensate drainage of virtually all types of steam-using equipment. Put the Screwed NPT and BSPT
inverted bucket to work in a tough cast iron package, and you have the best
of both worlds. Because they operate efficiently for longer periods of time, Materials
Armstrong cast iron inverted buckets add solid energy savings to lower
Body: ASTM A48 Class 30
replacement/labor costs.
Internals: All stainless steel—304
Valve and seat: Hardened chrome steel—440F
A unique leverage system multiplies the force provided by the bucket to open
Test plug: Carbon steel
the valve against system pressure. The mechanism is free-floating, and has
no fixed pivots to create wear or friction.
Options
Because the mechanism is located at the top of the trap, no dirt can collect • Stainless steel internal check valve
on the orifice. Small particles of dirt are held in suspension until discharged • Thermic vent bucket
by the full differential purging action when the bucket sinks, pulling the valve • Scrub wire
off the seat.
Specification
The discharge orifice is surrounded by a water seal, preventing live steam Inverted bucket steam trap, type ... in cast iron, with continuous air venting
loss. Automatic air venting is provided by a small vent hole in the bucket, which at steam temperature, free floating stainless steel mechanism, and discharge
provides continuous automatic air and CO2 venting at steam temperature. orifice at the top of the trap.

Inverted bucket traps drain continuously, although discharging intermittently,


allowing no condensate backup. They are also resistant to water hammer.
How to Order
Specify:
• Model number
Maximum Operating Conditions • Size and type of pipe connection
Maximum allowable pressure • Maximum working pressure that will be encountered or orifice size
(vessel design): 250 psig @ 450°F (17 bar @ 232°C) • Any options required
Maximum operating pressure: Model 211-216: 250 psig (17 bar)

200 Series, Bottom Inlet, Top Outlet Traps


Add suffix “CV” to model number for internal check valve, “T” for thermic vent bucket.
Model No. 211 212 213 214 215 216
in mm in mm in mm in mm in mm in mm
Pipe Connections 1/2 15 1/2, 3/4 15, 20 1/2, 3/4, 1 15, 20, 25 1, 1-1/4 25, 32 1, 1-1/4, 1-1/2 25, 32, 40 1-1/2, 2 40, 50
Test Plug 1/8 3 3/8 10 1/2 15 1/2 15 3/4 20 1 25
“A” (Flange Diameter) 4-1/4 108 5-1/4 133 6-3/8 162 7-1/2 190 8-1/2 216 10-3/16 259
“B” (Height) 6-3/8 162 8 203 10-3/4 273 12-1/2 317 14-5/16 364 17 432
Number of Bolts 6 8 6 8 12
Weight lb (kg) 6 (2.7) 11-1/2 (5.2) 20-1/4 (9.2) 33 (15.0) 44-3/4 (20.3) 77-1/2 (35.2)

All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice.

Armstrong International, Inc., 816 Maple St., P.O. Box 408, Three Rivers, MI 49093 – USA Phone: (616) 273-1415 Fax: (616) 278-6555
ST-13 www.armstrong-intl.com
Next
790 Steam Traps 1st quarter 6/19/00 8:57 AM Page ST-14

200 Series Inverted Bucket Steam Traps


Cast Iron for Vertical Installation
For Pressures to 250 psig (17 bar)...Capacities to 20,000 lb/hr (9,072 kg/hr)

Steam Tracing Equipment


Steam Trapping and
Model 211 Capacity Model 212 Capacity

Model 213 Capacity Model 214 Capacity

Model 215 Capacity Model 216 Capacity

Armstrong International, Inc., 816 Maple St., P.O. Box 408, Three Rivers, MI 49093 – USA Phone: (616) 273-1415 Fax: (616) 278-6555
www.armstrong-intl.com
ST-14
Next
790 Steam Traps 1st quarter 6/19/00 8:57 AM Page ST-15

800-813 Series Inverted Bucket Steam Trap


Cast Iron for Horizontal Installation
For Pressures to 250 psig (17 bar)...Capacities to 4,400 lb/hr (2,000 kg/hr)
Steam Tracing Equipment

C
Steam Trapping and

Description Connections
The most reliable steam trap known—the inverted bucket—provides efficient Screwed NPT and BSPT
condensate drainage of virtually all types of steam-using equipment. Put the
inverted bucket to work in a tough cast iron package, and you have the Materials
best of both worlds. Because they operate efficiently for longer periods of
Body: ASTM A48 Class 30
time, Armstrong cast iron inverted buckets add solid energy savings to lower
Internals: All stainless steel—304
replacement/labor costs. All Armstrong cast iron inverted bucket steam traps
Valve and seat: Hardened chrome steel—440F
are repairable for even bigger maintenance savings.
Test plug: Carbon steel
A unique leverage system multiplies the force provided by the bucket to open
the valve against system pressure. The mechanism is free-floating, and has Options
no fixed pivots to create wear or friction. • Stainless steel internal check valve
• Thermic vent bucket
Because the mechanism is located at the top of the trap, no dirt can collect • Stainless steel pop drain
on the orifice. Small particles of dirt are held in suspension until discharged • Probe connection
by the full differential purging action when the bucket sinks, pulling the valve • Thermo drain
off the seat. • Scrub wire

The discharge orifice is surrounded by a water seal, preventing live steam Specification
loss. Automatic air venting is provided by a small vent hole in the bucket, which Inverted bucket steam trap, type ... in cast iron, with continuous air venting
provides continuous automatic air and CO2 venting at steam temperature. at steam temperature, free-floating stainless steel mechanism, and discharge
orifice at the top of the trap.
Inverted bucket traps drain continuously, although discharging intermittently,
allowing no condensate backup. They are also resistant to water hammer.
How to Order
Specify:
Maximum Operating Conditions • Model number
Maximum allowable pressure • Size and type of pipe connection
(vessel design): 250 psig @ 450°F (17 bar @ 232°C) • Maximum working pressure that will be encountered or orifice size
Maximum operating pressure: Model 800: 150 psig (10 bar) • Any options required
Model 811-813: 250 psig (17 bar)

800-813 Series Side Inlet, Side Outlet Traps. Add suffix “CV” to model number for internal check valve, “T” for thermic vent bucket.
Model No. 800* 811 812 813
in mm in mm in mm in mm
Pipe Connections 1/2, 3/4 15, 20 1/2, 3/4, 1 15, 20, 25 1/2, 3/4 15, 20 3/4, 1 20, 25
Test Plug 1/4 6 1/4 6 1/2 15 3/4 20
“A” (Flange Diameter) 3-3/4 95.2 3-3/4 95.2 5-5/8 143 7 178
“B” (Height) 5-7/16 138 6-7/8 175 9-1/16 230 11-3/4 298
“C” (Face-to-Face) 5 127 5 127 6-1/2 165 7-3/4 197
“D” (Bottom to CL Inlet) 2-3/4 70 4-1/4 108 5-3/8 137 7-1/32 179
Number of Bolts 6
Weight lb (kg) 5 (2.3) 6 (2.7) 15 (6.8) 27-1/2 (12.5)
*Cannot be furnished with both thermic vent bucket and check valve.

All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice.

Armstrong International, Inc., 816 Maple St., P.O. Box 408, Three Rivers, MI 49093 – USA Phone: (616) 273-1415 Fax: (616) 278-6555
ST-15 www.armstrong-intl.com
Next
790 Steam Traps 1st quarter 6/19/00 8:57 AM Page ST-16

800-813 Series Inverted Bucket Steam Trap


Cast Iron for Horizontal Installation
For Pressures to 250 psig (17 bar)...Capacities to 4,400 lb/hr (2,000 kg/hr)

Steam Tracing Equipment


Steam Trapping and
Model 800 Capacity Model 811 Capacity

Model 812 Capacity Model 813 Capacity

Armstrong International, Inc., 816 Maple St., P.O. Box 408, Three Rivers, MI 49093 – USA Phone: (616) 273-1415 Fax: (616) 278-6555
www.armstrong-intl.com
ST-16
Next
790 Steam Traps 1st quarter 6/19/00 8:57 AM Page ST-17

814-816 Series Inverted Bucket Steam Trap


Cast Iron for Horizontal Installation
For Pressures to 250 psig (17 bar)...Capacities to 20,000 lb/hr (9,072 kg/hr)
Steam Tracing Equipment

C
Steam Trapping and

Description Connections
The most reliable steam trap known—the inverted bucket—provides efficient Screwed NPT and BSPT
condensate drainage of virtually all types of steam-using equipment. Put the
inverted bucket to work in a tough cast iron package, and you have the Materials
best of both worlds. Because they operate efficiently for longer periods of
Body: ASTM A48 Class 30
time, Armstrong cast iron inverted buckets add solid energy savings to lower
Internals: All stainless steel—304
replacement/labor costs. All Armstrong cast iron inverted bucket steam traps
Valve and seat: Hardened chrome steel—440F
are repairable for even bigger maintenance savings.
Test plug: Carbon steel
A unique leverage system multiplies the force provided by the bucket to open
the valve against system pressure. The mechanism is free-floating, and has Options
no fixed pivots to create wear or friction. • Stainless steel internal check valve
• Thermic vent bucket
Because the mechanism is located at the top of the trap, no dirt can collect • Stainless steel pop drain
on the orifice. Small particles of dirt are held in suspension until discharged • Probe connection
by the full differential purging action when the bucket sinks, pulling the valve • Thermo drain
off the seat. • Scrub wire

The discharge orifice is surrounded by a water seal, preventing live steam Specification
loss. Automatic air venting is provided by a small vent hole in the bucket, which Inverted bucket steam trap, type ... in cast iron, with continuous air venting
provides continuous automatic air and CO2 venting at steam temperature. at steam temperature, free-floating stainless steel mechanism, and discharge
orifice at the top of the trap.
Inverted bucket traps drain continuously, although discharging intermittently,
allowing no condensate backup. They are also resistant to water hammer.
How to Order
Specify:
Maximum Operating Conditions • Model number
Maximum allowable pressure • Size and type of pipe connection
(vessel design): 250 psig @ 450°F (17 bar @ 232°C) • Maximum working pressure that will be encountered or orifice size
Maximum operating pressure: Model 814-816: 250 psig (17 bar) • Any options required

814-816 Series Side Inlet, Side Outlet Traps. Add suffix “CV” to model number for internal check valve, “T” for thermic vent bucket.
Model No. 814 815 816
in mm in mm in mm
Pipe Connections 1, 1-1/4 25, 32 1, 1-1/4, 1-1/2, 2 25, 32, 40, 50 2, 2-1/2 50, 65
Test Plug 1 25 1-1/2 40 2 50
“A” (Flange Diameter) 8 203 9 229 11-1/2 292
“B” (Height) 13-5/8 346 16-1/4 413 21-5/16 541
“C” (Face-to-Face) 9 229 10-1/4 260 13 330
“D” (Bottom to CL Inlet) 7-13/16 198 8-1/16 205 11 279
Number of Bolts 8
Weight lb (kg) 44 (20.0) 71 (32.2) 131 (59.4)

All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice.

Armstrong International, Inc., 816 Maple St., P.O. Box 408, Three Rivers, MI 49093 – USA Phone: (616) 273-1415 Fax: (616) 278-6555
ST-17 www.armstrong-intl.com
Next
790 Steam Traps 1st quarter 6/19/00 8:57 AM Page ST-18

814-816 Series Inverted Bucket Steam Trap


Cast Iron for Horizontal Installation
For Pressures to 250 psig (17 bar)...Capacities to 20,000 lb/hr (9,072 kg/hr)

Steam Tracing Equipment


Steam Trapping and
Model 814 Capacity Model 815 Capacity

Model 816 Capacity

Armstrong International, Inc., 816 Maple St., P.O. Box 408, Three Rivers, MI 49093 – USA Phone: (616) 273-1415 Fax: (616) 278-6555
www.armstrong-intl.com
ST-18
Next
790 Steam Traps 1st quarter 6/19/00 8:57 AM Page ST-19

880 Series Inverted Bucket Steam Traps


Cast Iron for Horizontal Installation With Integral Strainer
For Pressures to 250 psig (17 bar)...Capacities to 4,400 lb/hr (2,000 kg/hr)
Steam Tracing Equipment

C
A
Steam Trapping and

Description Connections
The most reliable steam trap known—the inverted bucket—provides efficient Screwed NPT and BSPT
condensate drainage of virtually all types of steam-using equipment. Put the
inverted bucket to work in a tough cast iron package with an integral strainer, Materials
and you have the best of both worlds. Because they operate efficiently for
Body: ASTM A48 Class 30
longer periods of time, Armstrong cast iron inverted buckets add solid energy
Internals: All stainless steel—304
savings to lower replacement/labor costs. All Armstrong cast iron inverted
Valve and seat: Hardened chrome steel—440F
bucket steam traps are repairable for even bigger maintenance savings.
Test plug: Carbon steel
Strainer: Stainless steel—304
A unique leverage system multiplies the force provided by the bucket to open
the valve against system pressure. The mechanism is free-floating, and has
no fixed pivots to create wear or friction. Options
• Stainless steel internal check valve
Because the mechanism is located at the top of the trap, no dirt can collect • Thermic vent bucket
on the orifice. Small particles of dirt are held in suspension until discharged • Scrub wire
by the full differential purging action when the bucket sinks, pulling the valve
off the seat. Specification
Inverted bucket steam trap, type ... in cast iron with integral strainer, with
The discharge orifice is surrounded by a water seal, preventing live steam loss. continuous air venting at steam temperature, with free-floating stainless
Automatic air venting is provided by a small vent hole in the bucket, which steel mechanism, and discharge orifice at the top of the trap.
provides continuous automatic air and CO2 venting at steam temperature.

Inverted bucket traps drain continuously, although discharging intermittently,


How to Order
allowing no condensate backup. They are also resistant to water hammer. Specify:
• Model number
• Size and type of pipe connection
Maximum Operating Conditions • Maximum working pressure that will be encountered or orifice size
Maximum allowable pressure • Any options required
(vessel design): 250 psig @ 450°F (17 bar @ 232°C)
Maximum operating pressure: Model 880: 150 psig (10 bar)
Model 881-883: 250 psig (17 bar)

880 Series Side Inlet, Side Outlet Traps With Integral Strainers. Add suffix “CV” to model number for internal check valve, “T” for thermic vent bucket.
Model No. 880* 881 882 883
in mm in mm in mm in mm
Pipe Connections
1/2, 3/4 15, 20 1/2, 3/4, 1 15, 20, 25 1/2, 3/4 15, 20 3/4,1, 1-1/4 20, 25, 32
Test Plug 1/4 6 1/4 6 1/2 15 3/4 20
“A” (Flange Diameter) 3-3/4 95.2 3-3/4 95.2 5-5/8 142.9 7 177.8
“B” (Height) 6-1/16 154 7-1/16 179 9-3/8 244 12-3/8 314
“C” (Face-to-Face) 5 127 5 127 6-1/2 165 7-7/8 200
“D” (Bottom to CL Inlet) 3-7/16 87.3 4-7/16 113 5-3/4 146 7-3/8 187
“E” (Blowdown Connection) 3/8 9 3/8 9 3/8 9 1/2 15
Number of Bolts 6
Weight lb (kg) 5-1/2 (2.5) 6 (2.7) 15-1/2 (7.0) 31 (14.1)
*Cannot be furnished with both thermic vent bucket and check valve.

All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice.

Armstrong International, Inc., 816 Maple St., P.O. Box 408, Three Rivers, MI 49093 – USA Phone: (616) 273-1415 Fax: (616) 278-6555
ST-19 www.armstrong-intl.com
Next
790 Steam Traps 1st quarter 6/19/00 8:57 AM Page ST-20

880 Series Inverted Bucket Steam Traps


Cast Iron for Horizontal Installation With Integral Strainer
For Pressures to 250 psig (17 bar)...Capacities to 4,400 lb/hr (2,000 kg/hr)

Steam Tracing Equipment


Steam Trapping and
Model 880 Capacity Model 881 Capacity

Model 882 Capacity Model 883 Capacity

Armstrong International, Inc., 816 Maple St., P.O. Box 408, Three Rivers, MI 49093 – USA Phone: (616) 273-1415 Fax: (616) 278-6555
www.armstrong-intl.com
ST-20