Catalog HY14-2550/US Servovalves TOC
Technical Information Series DY01 Return to
SECTION
General Description TOC

Series DY01 are two stage, 4-way, flapper and nozzle


style servovalves. The DY01 servovalve combines a
spool and sleeve construction, and a high frequency
torque motor, for optimal performance. The unique rigid
pin feedback design avoids ball glitch problems, which
can occur in other types of servovalves. This valve is
rated for 210 Bar (3000 PSI) standard, or can be built
for 350 Bar (5000 PSI) service. The pressure ratings
are the same for both the tool steel construction or the
optional stainless steel spool and body.
The DY01 servovalve was specially designed for high C
precision flight simulator applications.

Features
• Precision lapped spool and sleeve.
• No ball glitch.
• Tool steel, or stainless steel, spool and body.
• Versatile 21.59 mm (0.850 in.) port circle, can mount to
standard 19.81 mm (0.780 in.) and 23.62 mm (0.930 in.)
port circle patterns.

Specifications
Flow Rating 3 and 11 LPM (1 and 3 GPM) Null Shift
@ 70 Bar (1000 PSID) with temperature ≤ 2% per 55°C (100°F)
with pressure ≤ 2% per 70 Bar (1000 PSI)
Supply Pressure 10 – 210 Bar (145 – 3000 PSI)
opt. 350 Bar (5000 PSI) Presssure Gain
% change in pressure per
Leakage Flow 0.42 – 0.95 LPM
1% change in input 30% Minimum, 70% Maximum
@ 70 Bar (1000 PSID) (0.11 – 0.25 GPM)
command
Tank Port Pressure 210 Bar (3000 PSI) Max.
Step Response 10 – 90%, < 8 ms
< 10 Bar (145 PSI) for
best performance Fluid Mineral Oil, 60 – 225 SSU
1000 SSU maximum
Input Command ±50 mA std.
Operating Temperature -1°C to + 82°C
Frequency Response > 180 Hz
(+30°F to +180°F)
@ 90° phase shift (See Performance Curves)
Protection Class NEMA 4, IP65
Non-Linearity ≤ 10%
Filtration ISO 4406 15/12 or better
Threshold ≤ 0.5%

DY01.indd, ddp

C23 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
www.comoso.com
Return to
ALPHA
Catalog HY14-2550/US Servovalves TOC
Ordering Information Series DY01 Return to
SECTION
TOC
DY01
Series Material Coils Wiring Seal Operating Flows Special
Options Pressure Options Factory Code for Special Options

Code Description
Omit Standard
D (Specify) See list below
Code Description
A Steel (standard)
Code Description
B Stainless Steel
1 3.8 LPM (1 GPM)

C
Z* Special (specify)
1.5 5.7 LPM (1.5 GPM)
* Material selection does not
3 11 LPM (3 GPM)
not affect operating pressure.

Code Description
Code Description Parallel Series
A 210 Bar (3000 PSI)
D 200 ohm (Std.) 50 mA 25 mA
B 350 Bar (5000 PSI)
F 80 ohm 80 mA 40 mA
Z Special (specify)
G 22 ohm 200 mA 100 mA
Operating pressure is independent
K 40 ohm 150 mA 75 mA of material selection.
L 360 ohm 30 mA 15 mA
M 475 ohm 40 mA 20 mA Code Description
R 750 ohm 30 mA 15 mA N Nitrile (standard)
T 1000 ohm 10 mA 5 mA V Fluorocarbon Weight: 1.0 kg (2.1 lbs.)
V 1200 ohm 40 mA 20 mA E * EPR
Z Special (specify) Z * Special (specify)
* Consult factory for delivery

Code Connector over: Flow P to C2 with:


Special Options:
C Port C1 (+) Signal to A, C
D Port C1 (+) Signal to B, D Consult factory for price, delivery and availability of special
Z Special (specify) options.
Special coil
Special wiring
Accessories Special seals
Special flow rate
Cable with Mating Connector: EHC154S Dual flow rate
Mating Connector: MS3106E-14S-2S Dual gain
Bolt Kit: Included with valve Zener barriers
Flushing Valve: 11-0500
Subplate: 55-0100-8S SAE-8 Side ports
Wiring Option C Wiring Option D
Null Adjust Tool: 6522A13 (Standard)
Electronic Drivers: 23-7030, BD90*, BD101* +
-
When used in conjunction with Series BD90 and BD101 servo ampli- DA
fiers or a motion controller, Series BD valves will provide accurate CB
control of rotary and linear actuators. +
- - +
* For output currents >15 mA
D A
Moog, Atchley and Vickers
C B
standard.
+ -

Polarity shown connects


P to C2 port.
Flushing valve is rated for 3000 psi operation.

DY01.indd, ddp

C24 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
www.comoso.com
Return to
ALPHA
Catalog HY14-2550/US Servovalves TOC
Technical Information Series DY01 Return to
SECTION
Performance Curves Frequency Response TOC

DY01 Flow vs. Pressure Drop


at 100% command
Flow Path: P C1 C2 T DY01 at 3000 PSI

Amplitude ratio (dB)


GPM LPM
20 76 +5
0
10 38 No
3 load -5
5 19 flow
curves -10

C
3 11 1.5 at
1 rated
Flow (Q)

flow
± 40% Amplitude

Phase lag (degrees)


1 4
-135
0.5 2 -90
0.3 1 -45
0
± 10% Amplitude
0.1 0.4
Bar 14 41 69 138 345 10 50 100 200 300
PSI 200 600 1000 2000 5000 Frequency (Hz)
Pressure Drop

Installation Wiring Options


This servovalve has two coils. This illustration shows the internal wiring configurations for options C and D. When
connecting the valve to a drive amplifier, the user’s external wiring may put the coils either in parallel or in series
as needed. Refer to the illustrations below and to the mounting pattern for this valve to insure proper control phas-
ing.

Option C Option D

A B C D A B C D

A B C D A B C D

Parallel Series

- + - +
Parallel Series

+ - + -

Polarity shown connects flow from P to C2 port.

DY01.indd, ddp

C25 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
www.comoso.com
Return to
ALPHA
Catalog HY14-2550/US Servovalves TOC
Dimensions Series DY01 Return to
SECTION
Inch equivalents for millimeter dimensions are shown in (**) TOC

Connector over port C1

C D A

C B

72.4
(2.85)
60.3
(2.38)
36.6
12.8 (1.40)
(0.50)
25.4
38.0
(1.00) 50.8
(1.50)
75.9 (2.00)
(2.99)
86.1
(3.39)

Mounting Interface
Inch equivalents for millimeter dimensions are shown in (**) 42.9
(1.69)
32.2
(1.27) 2.39 (0.094) 4.78 (0.188)
21.4
(0.84) 0.36
11.5 M
(0.014)
(0.45)
10.6
(0.42)

6.3
(0.25)
P

17.1
50.8 (0.67) 4.4 8.74 (0.344) Max.
(2.00) 27.9 (0.17) 4 Places
(1.10)
0.2
34.1 M
C2 C1 (0.008)
(1.34)

#1/4 – 20 NC –2B 9.53 (0.375) 63.5


4 Places (2.50)
0.18
M
(0.007)

DY01.indd, ddp

C26 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
www.comoso.com