Professional Documents
Culture Documents
Pressure Switch
EDS 3400
with Flush Membrane
height of digits 7 mm
Many useful additional functions Weight ~ 120 g
Option of Desina®-compliant Note: Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.
pin configuration with diagnostic FS (Full Scale) = relative to the full measuring range
1)
G1/2 with additional front O-ring seal max. 1500 bar
function 2)
Other seal materials on request
3)
-25 °C with FPM seal, -40 °C on request
4)
Environmental conditions according to 1.4.2 UL 61010-1; C22.2 No. 61010-1
89
Setting options: Model code:
All settings offered by the EDS 3400 are
grouped in 2 easy-to-navigate menus. EDS 3 4 Z X – X – XXXX – XXX – 000
In order to prevent unauthorised Mechanical process connection
adjustment of the device, a programming Z = Flush membrane
lock can be set. Electrical connection
6 = Male M12x1, 4 pole
only possible on output models "1", "2" and "3"
Setting ranges for the switch
8 = Male M12x1, 5 pole
outputs: only possible on output model "5"
Switching point function Output
Meas. Switch Hysteresis Incre- 1 = 1 switching output
range point ment* only in conjunction with electrical connection type "6"
in bar in bar in bar in bar 2 = 2 switching outputs
0 .. 40 0.6 .. 40 0.2 .. 39.6 0.1 only in conjunction with electrical connection type "6"
3 = 1 switching output and 1 analogue output
0 .. 100 1.6 .. 100 0.6 .. 99.0 0.2 only in conjunction with electrical connection type "6"
0 .. 250 4.0 .. 250 1.5 .. 247.5 0.5 5 = 2 switching outputs and 1 analogue output
0 .. 400 6.0 .. 400 2.0 .. 396 1 only in conjunction with electrical connection type "8"
Pressure ranges in bar
0 .. 600 9.0 .. 600 3.0 .. 594 1
0040; 0100; 0250; 0400; 0600
Mechanical connection
Window function G01 = G1/2 A DIN 3852
Meas. Lower Upper Incre- G02 = G1/2 with additional front O-ring seal
range switch switch ment* G04 = G1/4 with additional front O-ring seal
value value G05 = G1/4 A DIN 3852
in bar in bar in bar in bar G12 = G1/2 with add. front O-ring seal and cooling section
0 .. 40 0.6 .. 39.2 0.9 .. 39.6 0.1 Modification number
0 .. 100 1.6 .. 98.2 2.4 .. 99 0.2 000 = Standard
0 .. 250 4.0 .. 245.5 6.0 .. 247.5 0.5
0 .. 400 6.0 .. 392 9.0 .. 396 1
0 .. 600 9.0 .. 589 14 .. 594 1 Model code:
* All ranges given in the table DESINA®-compliant or
are adjustable by the increments can be connected to DESINA®:
shown.
90
Dimensions: Pin connections:
installation dimension Ø 53.5
M12x1, 4 pole
housing
turns thru M12x1, 5 pole
340°
4 3
5
hex-SW27
1 2
elastomer
profile gasket
DIN 3869
[G01]
Pin EDS
34Z8-5
1 +UB
2 Analogue
3 0V
4 SP 1 4
hex-SW27 hex-SW27
seal ring DIN3869 seal ring DIN3869 5 SP 2
18.5 x 23.9 x 1.5 11.6 x 16.5 x 1.5
4 3
5
[G02] [G04]
1 2
hex-SW27
hex-SW27
seal ring DIN3869 DESINA®- Can be
18.5 x 23.9 x 1.5 compliant connected to
DESINA®
Pin EDS EDS
hex-SW27 34Z8-1 34Z8-3
[G05]
seal ring DIN3869 1 +UB +UB
18.5 x 23.9 x 1.5
O-ring 15 x 2
2 Diagnostics Diagnostics
3 0V 0V
4 SP 1 SP 1
5 n.c. Analogue
[G12]
Note:
E 18.377.1/11.13
91
4
92
E 18.377.1/11.13