You are on page 1of 1

NOTES

ROOF: CONCRETE ROOF TILES ON TRUSSES

- TILES ON 38x38mm BATTENS AT 320mm CENTRES MAX

EMBEDDED AT LEAST 300mm INTO BRICKWORK WITH CONNECTING DEVICES ACCORDING TO


TABLE L2, SCHEDULE 1, OF SABS 0400
-ALL WEB MEMBERS TO BE MINIMUM 38x114mm GRADE 4 WITH EQUAL BAYS SMALLER
THAN 1500mm. APPROVED BRACING MUST PREVENT BUCKLING AND KEEP TRUSSES UPRIGHT
-VALLEY AND HIP RAFTERS TO BE GRADE 6 50x228 SA PINE
-LAMINATED TIMBER TO COMPLY WITH SABS 876
-50mm GLASS FIBRE INSULATION TO BE INSTALLED ON CEILING

CONCRETE ROOF
-CONCRETE ROOF TO ENGINEER'S DETAIL WITH MINIMUM 50mm THICKNESS
-VERMICULITE SCREED GRADED TO 1:50 FALL TO 100m DIAMETER BILD IN DOWNPIPES

-WATERPROOFING BY SPECIALIST WITH A TEN YEAR GUARANTEE AS PER SPECIFICATION

FLOORS AND WATERPROOFING


-GROUND FLOOR SLAB=85mm THICK 20mpa CONCRETE PERFECTLY LEVEL AND AT
MINIMUM 150mm ABOVE GROUND LEVEL ON PROPERLY COMPACTED HARDCORE FILL
-25mm THICK SCREED AND FINISHES AS INDICATED
-SUSPENDED CONCRETE FLOOR SLABS TO ENGINEER'S DETAIL AND SPECIFICATIONS
-DPC UNDER ALL WALLS (EXCEPT FREE STANDING), FLOORS AND WINDOW SILLS
AND TO ALL VERTICAL CHANGES IN FLOOR LEVELS
-FLUSHINGS TO ALL PARAPETS AND CHANGES IN ROOF LEVELS

FROM CATCHPIT FITTED WITH GRATING AND SILT TRAP


-PLANTERS TO BE WATERPROOFED AND DRAINAGE INSTALLED

FOUNDATIONS, BRICKWORK & PARTITIONS


-ALL FOUNDATIONS TO BE 25mpa CONCRETE , AT LEAST 200x700mm. MINIMUM
200mm UNDER GROUND TO ENGINEER'S DETAILS AND SPECIFICATIONS
-BOUNDARY WALLS' FOUNDATION MUST NOT ENCROACH ON BOUNDARY AND WALLS
ARE TO BE PLASTERED AND PAINTED ON THEW INNER WALL
-PARAPET WALLS TO BE ATLEAST 300mmHIGH AND MAXIMUM 500mm WITH BRICKFORCE
IN EVERY COURSE
-ALL SCREEN WALLS TO BE AT LEAST 1800mm HIGH ABOVE GROUND LEVEL

230
405 690 405
LEDGE
-LINTOLS TO BE SUPPORTED MINIMUM 150mm FOR OPENINGS UPTO 4800mm.BRICKFORCE

230 230

1500

1390
TO BE BUILT IN EVERY COURSE BELOW FLOOR LEVEL AND ABOVE WINDOW LEVEL, EVERY
SEPTIC TANK SOAKAWAY THIRD COURSE BETWEEN BETWEEN IN CONTINOUS BANDS

230
LEDGE -NO TEETHING OR BLOCK BONDING WILL BE ALLOWED UNDER ANY CIRCUMSTANCES
-ANY PARTITION TO BE RODENT PROOF

STAIRS AND BALUSTRADES


3000 4000
600 -STAIRS TO BE 750mm MIN WIDTH, TREADS 300mm , RISERS 170mm WITH 6mm MAX DEVIATION
230 230 230 -1000mm HIGH BALUSTRADES TO ALL STAIRS AND BALCONIES
-MAX 3000mm VERTICAL RISE PER FLIGHT , WINDERS WHERE SHOWN ,TO BE AT LEAST 250mm
WIDE, 450mm FROM THE NARROW END AND ANGLE BETWEEN THE RISERS TO BE CONSTANT
-MINIMUM HEADROOM TO BE 2100mm MEASURED FROM PICHLINE
-GLASS BALUSTRADES (IF SHOWN ) TO BE SAFETY GLASS

GLAZING

ELECTRICAL KEY
LIGHT SWITCH -BATHROOM WINDOWS TO BE FROSTED GLASS
60x40mm wrought-iron
corrugated zinc sheets or -ALL GLAZING ON DOORS TO BE SATETY GLASS
manhole covers 100mm r c slab 400mm deep fine sand
inspection eye flattened drums laid on top -ALL GLAZED AREA LESS THAN 300MM ABOVE FFL TO BE COVERED WITH SATETY GLASS
NGL NGL
depth dependant on invert AREA SCHEDULE
MAN-HOLE
depth of incoming pipe
GROUND FLOOR AREA
150mm porous concrete agricultural
SEPTIC TANK SITE PLAN AREA =
drain pipes laid@ fall 1:60 & with 12mm
open joints SITE COVERAGE = %
SOAKAWAY

internal plaster to be
watertight & smooth
DOORS & WINDOWS SCHEDULE
SEE SCHEDULE DRAWINGS OF DOORS AND WINDOWS
38mm stone aggregate rock fill
75mm CONC FOOTING
DO NOT SCALE THE DRAWINGS

length to be determined on site, min 1200mm

pop up
plug

STEEL PALISADES BY SPECIALIST

plaster&paint to plaster&paint to
be earthly tones be earthly tones
owner's choice owner's choice
STEEL PALISADES

NOTE :BOUNDARY WALLS TO MATCH HOUSE & TO BE


CEMENT / EQUALLY APPROAVED MAINTANANCE FREE ON NEIGHBOURS SIDE
CAPPING & WATER PROOFING CEMENT / EQUALLY APPROAVED
CAPPING & WATER PROOFING
440x440mm BRICK PIER

STEEL PALISADES TO 220mm BRICK WALL PAINTED & PLASTERED


SPECIALIST DESIGN AND TO CLIENT'S COLOUR & CHOICE
SPECIFICATIONS
steel palisades by specialist 440x440mm BRICK PIER
450x220mm THICK BRICK WALL
PAINTED & PLASTERED
440x440mm 440x440mm TO CLIENT'S COLOUR & CHOICE 110mm BRICK WALL PAINTED & PLASTERED
BRICK PIER BRICK PIER TO CLIENT'S COLOUR & CHOICE

600x230mm CONC FOOTING


440x440mm 440x440mm
BRICK PIER BRICK PIER

600x230mm CONC FOOTING