You are on page 1of 3

Set 1 Set 2 Set 3 Set 4

CW HW CW HW CW HW CW HW
Nominal Flow :
m3/Hr
:USGPM
Actual Flow : m3/Hr FC:2.27 m3/Hr FH:1.36m3/H FC:2.27 FH:2.27m3/Hr FC:3.41 FH:2.27 FC:4.54 FH:2.27 m3/Hr
:USGPM : 6 USGPM r m3/Hr : 10 USGPM m3/Hr m3/Hr m3/Hr : 10 USGPM
Temp, ˚C, Inlet T1: 33.4 ˚C : 10 USGPM : 10 USGPM T1: 61.7 ˚C : 10 USGPM : 15 USGPM : 20 USGPM T1: 60.1 ˚C
Temp, ˚C, Outlet T2: 53.6 ˚C T1: 63.2 ˚C T1: 33.6 ˚C T2: 49.4 ˚C T1: 35.2 ˚C T1: 60.7 ˚C T1: 37.1 ˚C T2: 53.3 ˚C
T2: 52.6 ˚C T2: 49.4 ˚C T2: 51.9 ˚C T2: 51.8 ˚C T2: 54.2 ˚C
Pressure, psig, Inlet PG-C: 8.0 PG-H: 3.5 PG-C: 10 PG-H: 3.0 PG-C: 10 PG-H: 8.8 PG-C: 10 PG-H: 14
Pressure Drop, mm DP(Shell): 320 DP(Tube):96 DP(Shell): DP(Tube): DP(Shell): DP(Tube):217 DP(Shell): DP(Tube):342
H2O 1 939 991 948 9 928 3

Calculate Following:
Temp Change, ˚C T2-T1: 20.2 T2-T1: -10.6 T2-T1: 15.8 T2-T1: -12.3 T2-T1: 16.7 T2-T1: -8.9 T2-T1: 17.1 T2-T1: -6.8
Average Temp, ˚C T 2+ T 1 T 2+ T 1 T 2+ T 1 T 2+ T 1 T 2+ T 1 T 2+ T 1 T 2+ T 1 T 2+ T 1
: : : : : : :
Q, Head Load, 2 2 2 2 2 2 2 2
BTU/HR 43.5 : 57.9 41.5 55.55 43.55 56.25 45.65 56.7
QC: QH: QC: QH: QC: QH: QC: QH:
1.091x105 -9.545x104 1.423x105 -1.108x105 1.504x105 -1.202x105 3.08x105 -6.123x104
Compute ratio QC QC QC QC
: -1.143 : -1.284 : -1.251 : -5.03
QC QH QH QH QH
QH
SELECT Set 1 or Set Set 1 is Set 2 is Set 3 is Set 4 is
2 or Set 3,Set 4 Selected / Not Selected Selected / Not Selected Selected / Not Selected Selected / Not Selected
based on the best
convergence of QC
and QH
QC
i.e. is
QH
nearest to 1.0
For selected
Set,compute 0.5 6825 - - -
(QC+QH). BTU/HR

You might also like