You are on page 1of 4

PARKIR PINTAR (SMART PARKING).

zm2

Program information
Author : Oki
Project name : Parkir Pintar
Version : 0.0
Module : SR3B261BD
Cycle time in the module : 8 x 2 ms
WATCHDOG action : Inactive
Type of Hardware Input Filtering : Slow (3ms)
Zx keys inactive

Date format : 15/12/2016


Daylight Saving Time change activated
Zone : Europe
Change to Daylight Saving Time : March, Last Sunday
Return to winter time : October, Last Sunday

Author 12/16/2016 1/4


PARKIR PINTAR (SMART PARKING).zm2

Program diagram
No Contact 1 Contact 2 Contact 3 Contact 4 Contact 5 Coil Comment
I5 i6 ± M3 TOMBOL START/OFF

001

START/ON STOP/OFF REALY 3


M3 ± M4 MENGAKTIFKAN SENSOR MASUK
DAN SENSOR KELUAR
002

REALY 3 REALY 4
M3 ± Q5 LAYAR LCD "SELAMAT DATANG"
AKTIF
003

REALY 3 TAMPILKAN LAY...


I1 t1 c1 M4 ± Q1 PINTU MASUK TERBUKA

004

SENSOR PINTU ... TIMER 1 COUNTER PARK... REALY 4 PORTAL MASUK


Q1 ± Q3 LAYAR SELAMAT DATANG DAN POSISI

005

PORTAL MASUK TAMPILAN LAYA...


± M5 MENGAKTIFKAN SENSOR COUNT UP

006

REALY 5
I2 M5 TT1 SENSOR COUNTER MENGAKTIFKAN
TIMER 1
007

SENSOR COUN... REALY 5 TIMER 1


T1 ± M1 TIMER 1 MENGAKTIFKAN REALY 1

008

TIMER 1 REALY 1
I3 t2 M4 ± Q2 PINTU KELUAR TERBUKA

009

SENSOR PINTU ... TIMER 2 REALY 4 PORTAL KELUAR


Q2 ± Q4 LAYAR SELAMAT JALAN

010

PORTAL KELUAR TAMPILAN LAYA...


± M6 MENGAKTIFKAN SENSOR COUNT
DOWN
011

REALY 6
I4 M6 TT2 SENSOR COUNTER MENGAKTIFKAN
TIMER 2
012

SENSOR COUN... REALY 6 TIMER 2


T2 ± M2 TIMER 2 MENGAKTIFKAN REALY 2

013

TIMER 2 REALY 2
I2 m1 M5 CC1 SENSOR COUNTER UP DAN DOWN
SERTA REALY 1 MENGINPUT PADA
014 COUNTER
SENSOR COUN... REALY 1 REALY 5 COUNTER PARK...
I4 m1 M6
015

SENSOR COUN... REALY 1 REALY 6


I4 DC1 COUNT DOWN AKTIF

016

SENSOR COUN... COUNTER PARK...

017

018

019

020

Author
021 12/16/2016 2/4
PARKIR PINTAR (SMART PARKING).zm2

Physical inputs
No Symbol Function Lock Parameters Location of (L/C) Comment
I1 Discrete inputs --- No parameters (4/1) SENSOR PINTU MASUK

I2 Discrete inputs --- No parameters (7/1) (14/1) SENSOR COUNT UP

I3 Discrete inputs --- No parameters (9/1) SENSOR PINTU KELUAR

I4 Discrete inputs --- No parameters (12/1) (15/1) (16/1) SENSOR COUNT DOWN

I5 Discrete inputs --- No parameters (1/1) START/ON

I6 Discrete inputs --- No parameters (1/2) STOP/OFF

Physical outputs
No Symbol Function Latching Location of (L/C) Comment
Discrete
Q1 No (4/6) (5/1) PORTAL MASUK
outputs
Discrete
Q2 No (9/6) (10/1) PORTAL KELUAR
outputs
Discrete
Q3 No (5/6) TAMPILAN LAYAR MASUK
outputs
Discrete
Q4 No (10/6) TAMPILAN LAYAR KELUAR
outputs
Discrete
Q5 No (3/6) TAMPILKAN LAYAR SELAMAT DATANG
outputs

Configurable functions
No Symbol Function Lock Latching Parameters Location of (L/C) Comment
Value to attain: 5 Pulses
C1 Counters No No Output ON when the preset value is reached (4/3) (14/6) (16/6) COUN...
M1 Auxiliary relays --- No No parameters (8/6) (14/2) (15/2) REAL...

M2 Auxiliary relays --- No No parameters (13/6) REAL...

M3 Auxiliary relays --- No No parameters (1/6) (2/1) (3/1) REAL...

M4 Auxiliary relays --- No No parameters (2/6) (4/4) (9/3) REAL...

M5 Auxiliary relays --- No No parameters (6/6) (7/2) (14/3) REAL...

M6 Auxiliary relays --- No No parameters (11/6) (12/2) (15/3) REAL...

T1 Timers No No See details below (4/2) (7/6) (8/1) TIMER 1

T2 Timers No No See details below (9/2) (12/6) (13/1) TIMER 2

Timer

T1 Timers TIMER 1
Function A: Active, control held down
Time: 003.0 s

Author 12/16/2016 3/4


PARKIR PINTAR (SMART PARKING).zm2

T2 Timers TIMER 2
Function A: Active, control held down
Time: 003.0 s

Author 12/16/2016 4/4