You are on page 1of 18

Wall Thickness= 228 mm

Wall Height Above NSL= 1 m


Wall Material Density= 1930 kg/m3
Allowable Soil Bearing Capacity= 75 kPa
Allowable Soil Bearing Capacity for One Sided Footing= 48.75 kPa
Depth of Footing Below NSL= 1.2 m
Factor to Account Load Eccentricity Effect= 1
Factor for Footing Type= 1 (1 is for One Sided Footing, 2
Thickness of PCC Pad Under Footing= 75 mm
Extra Axial Load on Wall= 0 kg/m
Wall Self Load= 440.04 kg/m
Total Load= 440.04 kg/m
Approaximate Footing Width Required= 228 mm
Number of Steps Required= 0
Rounded Number of Steps Required= 0
Total Base Width Required= 303 mm
One Sided Footing, 2 for Double Sided Footing)
Wall Thickness= 228 mm
Wall Height Above NSL= 2 m
Wall Material Density= 1930 kg/m3
Allowable Soil Bearing Capacity= 75 kPa
Allowable Soil Bearing Capacity for One Sided Footing= 48.75 kPa
Depth of Footing Below NSL= 1.2 m
Factor to Account Load Eccentricity Effect= 1
Factor for Footing Type= 1 (1 is for One Sided Footing, 2
Thickness of PCC Pad Under Footing= 75 mm
Extra Axial Load on Wall= 0 kg/m
Wall Self Load= 880.08 kg/m
Total Load= 880.08 kg/m
Approaximate Footing Width Required= 239.478 mm
Number of Steps Required= 0
Rounded Number of Steps Required= 0
Total Base Width Required= 303 mm
One Sided Footing, 2 for Double Sided Footing)
Wall Thickness= 228 mm
Wall Height Above NSL= 3 m
Wall Material Density= 1930 kg/m3
Allowable Soil Bearing Capacity= 75 kPa
Allowable Soil Bearing Capacity for One Sided Footing= 48.75 kPa
Depth of Footing Below NSL= 1.2 m
Factor to Account Load Eccentricity Effect= 1
Factor for Footing Type= 1 (1 is for One Sided Footing, 2
Thickness of PCC Pad Under Footing= 75 mm
Extra Axial Load on Wall= 0 kg/m
Wall Self Load= 1320.12 kg/m
Total Load= 1320.12 kg/m
Approaximate Footing Width Required= 359.216 mm
Number of Steps Required= 0.49313
Rounded Number of Steps Required= 1
Total Base Width Required= 417 mm
One Sided Footing, 2 for Double Sided Footing)
Wall Thickness= 228 mm
Wall Height Above NSL= 4 m
Wall Material Density= 1930 kg/m3
Allowable Soil Bearing Capacity= 75 kPa
Allowable Soil Bearing Capacity for One Sided Footing= 48.75 kPa
Depth of Footing Below NSL= 1.2 m
Factor to Account Load Eccentricity Effect= 1
Factor for Footing Type= 1 (1 is for One Sided Footing, 2
Thickness of PCC Pad Under Footing= 75 mm
Extra Axial Load on Wall= 0 kg/m
Wall Self Load= 1760.16 kg/m
Total Load= 1760.16 kg/m
Approaximate Footing Width Required= 478.955 mm
Number of Steps Required= 1.54347
Rounded Number of Steps Required= 2
Total Base Width Required= 531 mm
One Sided Footing, 2 for Double Sided Footing)
Wall Thickness= 228 mm
Wall Height Above NSL= 5 m
Wall Material Density= 1930 kg/m3
Allowable Soil Bearing Capacity= 75 kPa
Allowable Soil Bearing Capacity for One Sided Footing= 48.75 kPa
Depth of Footing Below NSL= 1.2 m
Factor to Account Load Eccentricity Effect= 1
Factor for Footing Type= 1 (1 is for One Sided Footing, 2
Thickness of PCC Pad Under Footing= 75 mm
Extra Axial Load on Wall= 0 kg/m
Wall Self Load= 2200.2 kg/m
Total Load= 2200.2 kg/m
Approaximate Footing Width Required= 598.694 mm
Number of Steps Required= 2.59381
Rounded Number of Steps Required= 3
Total Base Width Required= 645 mm
One Sided Footing, 2 for Double Sided Footing)
Wall Thickness= 228 mm
Wall Height Above NSL= 6 m
Wall Material Density= 1930 kg/m3
Allowable Soil Bearing Capacity= 75 kPa
Allowable Soil Bearing Capacity for One Sided Footing= 48.75 kPa
Depth of Footing Below NSL= 1.2 m
Factor to Account Load Eccentricity Effect= 1
Factor for Footing Type= 1 (1 is for One Sided Footing, 2
Thickness of PCC Pad Under Footing= 75 mm
Extra Axial Load on Wall= 0 kg/m
Wall Self Load= 2640.24 kg/m
Total Load= 2640.24 kg/m
Approaximate Footing Width Required= 718.433 mm
Number of Steps Required= 3.64415
Rounded Number of Steps Required= 4
Total Base Width Required= 759 mm
One Sided Footing, 2 for Double Sided Footing)
Wall Thickness= 228 mm
Wall Height Above NSL= 7 m
Wall Material Density= 1930 kg/m3
Allowable Soil Bearing Capacity= 75 kPa
Allowable Soil Bearing Capacity for One Sided Footing= 48.75 kPa
Depth of Footing Below NSL= 1.2 m
Factor to Account Load Eccentricity Effect= 1
Factor for Footing Type= 1 (1 is for One Sided Footing, 2
Thickness of PCC Pad Under Footing= 75 mm
Extra Axial Load on Wall= 0 kg/m
Wall Self Load= 3080.28 kg/m
Total Load= 3080.28 kg/m
Approaximate Footing Width Required= 838.171 mm
Number of Steps Required= 4.69449
Rounded Number of Steps Required= 5
Total Base Width Required= 873 mm
One Sided Footing, 2 for Double Sided Footing)
Wall Thickness= 228 mm
Wall Height Above NSL= 8 m
Wall Material Density= 1930 kg/m3
Allowable Soil Bearing Capacity= 75 kPa
Allowable Soil Bearing Capacity for One Sided Footing= 48.75 kPa
Depth of Footing Below NSL= 1.2 m
Factor to Account Load Eccentricity Effect= 1
Factor for Footing Type= 1 (1 is for One Sided Footing, 2
Thickness of PCC Pad Under Footing= 75 mm
Extra Axial Load on Wall= 0 kg/m
Wall Self Load= 3520.32 kg/m
Total Load= 3520.32 kg/m
Approaximate Footing Width Required= 957.91 mm
Number of Steps Required= 5.74483
Rounded Number of Steps Required= 6
Total Base Width Required= 987 mm
One Sided Footing, 2 for Double Sided Footing)
H (mm) 1000 2000 3000 4000 5000
B (mm) 531 531 531 531 645
Number of Brick Steps 2 2 2 2 3
6000 7000 8000
759 873 987
4 5 6

You might also like