You are on page 1of 3

PRODUCT DATA SHEET

Sikagard®-63 N
2-PART EPOXY PROTECTIVE COATING

DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sikagard®-63 N is a two part, rigid, total solid, col- ▪ Solvent free
oured epoxy resin based protective coating. ▪ Good mechanical and chemical resistance
▪ High build
USES ▪ Impervious to liquids
▪ Easy to mix and to apply
▪ Chemical resistant protective layer on concrete,
stone, cementitious mortars and renderings, epoxy SUSTAINABILITY
cement, epoxy resin based products and steel
▪ Lining in storage tanks and silos According USGBC LEED Rating Sikagard®-63N con-
▪ Anti-corrosion coating on steel in food processing forms to the requirements of LEED EQ Credit 4.2: Low
plants, sewage works, farms, agricultural enterprises, –Emitting Materials: Paints & Coatings SCAQMD Meth-
chemical and pharmaceutical facilities and beverage od 304-91 VOC Content < 100g/l.
industry
APPROVALS / STANDARDS
Coating for concrete protection according the require-
ments of EN 1504-2/2004.

PRODUCT INFORMATION
Chemical base Epoxy resin
Packaging Part A 8.70 kg can
Part B 1.3 kg can

Appearance / Colour Resin - Part A: Coloured, liquid


Hardener - Part B: Transparent, liquid
Pebble grey (~ RAL 7032). Additional colour shades on request.
Under sun radiation it may come to discolouration and colour deviation;
this has no influence to the function of the coating.
Shelf life 12 month from date of production
Storage conditions The packaging must be stored properly in original, unopend and undam-
aged sealed packaging, in dry conditions at temperatures between +5 °C
and +30 °C. Protected from direct sunlight.
Density Mixed resin ~ 1.35 kg/L (EN ISO 2811-1)
Density values determined at +23 °C
Solid content ~100 %

Product Data Sheet


Sikagard®-63 N
April 2017, Version 01.01
020606010030000001

1/3
TECHNICAL INFORMATION
Tensile Adhesion Strength ~1.5 N/mm² to concrete (ISO 4624)
~15 N/mm² to steel (EN 24624)
~10 N/mm2 to aluminium (EN 24624)

Chemical Resistance For further information please contact Sika Technical Service.
Thermal Resistance Exposure Dry heat
Permanent +40 °C
max. 3 days +60 °C

Diffusion Resistance to Water Vapour µH2O ~ 100 000 (EN ISO 7783-1)

APPLICATION INFORMATION
Mixing ratio Part A : Part B = 83 : 17 by weight
Consumption ~ 0.15 kg/m² per layer
Layer Thickness ~ 0.1 mm per layer
Ambient Air Temperature +10 °C … +30 °C
Relative Air Humidity < 80 %
Substrate Temperature +10 °C … +40 °C
≥ 3 °C above dew point, beware of condensation
Pot Life Temperature Time
+10 °C ~ 30 min
+20 °C ~ 20 min
+30 °C ~ 10 min

Waiting Time / Overcoating Temperature Min. Max. Full Cure


+10 °C 9h 3d 14 d
+20 °C 5h 2d 9d
+30 °C 4h 1d 5d

APPLICATION INSTRUCTIONS All dust, loose and friable material must be com-
pletely removed from all surfaces before application of
SUBSTRATE QUALITY the product, preferably by brush and/or vacuum.

The concrete substrate must be sound and of suffi- MIXING


cient compressive strength (minimum 25 N/mm2) with
a minimum pull off strength of 1.5 N/mm2. Prior to mixing stir part A mechanically. When all of
The substrate must be clean, dry and free of all con- part B has been added to part A mix continuously for 3
taminants such as dirt, oil, grease, coatings and sur- minutes until an uniform mixed has been achieved.
face treatments, etc. Use a low speed electrical stirrer (300 - 400 rpm) to
If in doubt apply a test area first. avoid air entrapment. To ensure proper mixing pour
material into a clean container and stir again.
SUBSTRATE PREPARATION
APPLICATION
Concrete substrates must be prepared mechanically
using abrasive blast cleaning or scarifying equipment Apply by brush, short piled roller or airles spray.
to remove cement laitance and achieve an open tex- CLEANING OF TOOLS
tured surface.
Weak concrete must be removed and surface defects Clean all tools with Thinner C immediately after use.
such as blowholes and voids must be fully exposed. Hardened and/or cured material can only be removed
Repairs to the substrate, filling of blowholes/voids and mechanically.
surface levelling must be carried out using appropri-
ate products from the Sikagard®, Sikafloor®, SikaDur®
and Sika MonoTop® range of materials.
The concrete or screed substrate has to be primed or
levelled in order to achieve an even surface.
High spots must be removed by e.g. grinding.

Product Data Sheet


Sikagard®-63 N
April 2017, Version 01.01
020606010030000001

2/3
LIMITATIONS LEGAL NOTES
This product may only be used by experienced profes- The information, and, in particular, the recommenda-
sionals. Do not apply Sikagard®-63 N on moist sub- tions relating to the application and end-use of Sika
strates. Sag resistance on vertical surface is < 100μm. products, are given in good faith based on Sika's cur-
Sikagard®-63 N cannot be used to produce glass fibre rent knowledge and experience of the products when
reinforced linings. Freshly applied Sikagard®-63 N must properly stored, handled and applied under normal
be protected from rain, condensation and water for at conditions in accordance with Sika's recommenda-
least 24 hours. For exact colour matching ensure the tions. In practice, the differences in materials, sub-
use the same control batch numbers. strates and actual site conditions are such that no war-
ranty in respect of merchantability or of fitness for a
BASIS OF PRODUCT DATA particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
All technical data stated in this Data Sheet are based from this information, or from any written recom-
on laboratory tests. Actual measured data may vary mendations, or from any other advice offered. The
due to circumstances beyond our control. user of the product must test the product’s suitability
for the intended application and purpose. Sika re-
LOCAL RESTRICTIONS serves the right to change the properties of its
products. The proprietary rights of third parties must
Please note that as a result of specific local regula- be observed. All orders are accepted subject to our
tions the declared data and recommended uses for current terms of sale and delivery. Users must always
this product may vary from country to country. Please refer to the most recent issue of the local Product Data
consult the local Product Data Sheet for the exact Sheet for the product concerned, copies of which will
product data and uses. be supplied on request.

ECOLOGY, HEALTH AND SAFETY


For information and advice on the safe handling, stor-
age and disposal of chemical products, users shall refer
to the most recent Safety Data Sheet (SDS) containing
physical, ecological, toxicological and other safety-re-
lated data.
DIRECTIVE 2004/42/CE - LIMITATION OF EMISSIONS
OF VOC
According to the EU-Directive 2004/42, the maximum
allowed content of VOC (Product category IIA / j type
sb) is 500 g/l (Limits 2010) for the ready to use
product. The maximum content of Sikagard®-63 N is
<500 g/l VOC for the ready to use product.

PT. Sika Indonesia


Jl. Raya Cibinong-Bekasi km.20.
Cileungsi, Bogor 16820 - Indonesia
Tel. +62 21 8230025
Fax. +62 21 8230026
Website: idn.sika.com
email: sikacare@id.sika.com

Sikagard-63N_en_ID_(04-2017)_1_1.pdf

Product Data Sheet


Sikagard®-63 N
April 2017, Version 01.01
020606010030000001

3/3

You might also like