Wall Ties and


Restraint Fixings
for the Construction Industry
2
Wall ties and restraint fixings are an essential
element in the stability of masonry panels.
Ancon manufactures fixings in a variety of
lengths and types for restraining brickwork,
blockwork and stonework. Restraints can be
fixed to concrete and structural steelwork as
well as any type of masonry. Products are
Ancon designs and manufactures high integrity steel products for
manufactured from stainless steel unless
the construction industry. Through continuous programmes of stated otherwise.
new product development, inward investment and employee The range of standard ties provides a solution
for all types of wall construction and many
advancement, the company is committed to maintaining the
products can be delivered in 24 hours.
highest level of customer service within a dynamic and These items are shown in red italics.

challenging industry.
Masonry Support Systems Cavity Wall Tie Selection 4-6
Installation Guidance 7
Lintels Ties for Brick-to-Block Construction 8-9
Ties for Cavities over 150mm 10
Masonry Reinforcement Slip Brick Ties 10
Ties for Steel Studwork 11
Windposts and Parapet Posts Ties for Thin-Joint Blockwork 12
Ties for Bubble Foil Insulation 13
Wall Ties and Restraint Fixings
Ties for Timber Frames 13
Frame Cramps and Channel Ties 14-16
Channel and Bolt Fixings
Vertical Movement Joints 17
Tension and Compression Systems Standard Wall Ties 18
Bespoke Wall Tie References 19
Insulated Balcony Connectors Non-Drill Fixings for Steelwork 20-21
Head Restraints & Sliding Anchors 22-23
Shear Load Connectors Wall Starter Systems 24
Restraints for Stone Cladding 25-28
Punching Shear Reinforcement Remedial Wall Ties 29-30
Staifix-Thor Helical Crack Stitching Kit 31
Reinforcing Bar Couplers
Other Ancon Products 31

Reinforcement Continuity Systems

Stainless Steel Fabrications

Flooring and Formed Sections

Refractory Fixings
ISO 9001: 2008 ISO 14001: 2004 OHSAS 18001: 2007
FM12226 EMS 505377 OHS 548992

Ancon product information


is available in NBS format
for easy insertion into a
NBS specification

3
Wall Ties and Restraint Fixings

CAVITY WALL TIE SELECTION BS 5628, Code of Practice for the


The selection and spacing of wall ties depend Use of Masonry
on many factors. These include type of BS 5628 was withdrawn when the Eurocode
masonry to be tied, cavity width, type and became the accepted National code in March
height of building, location, and design life. 2010. The majority of information in this British
There are several documents which need to be Standard has been reproduced in PD 6697:
consulted and are summarised here. 2010.
Eurocode 6 – Design of Masonry BS 5268-6.1: 1996 (Incorporating

© Hazle McCormack Young


Structures (BS EN 1996-1-1: 2005) Amendments No. 1 and 2): Structural use
In 2010, Eurocode 6 became the main code of timber – Dwellings not exceeding seven
for the design of reinforced and unreinforced storeys
masonry. Eurocode 6 refers to EN 845-1 for BS 5268 provides recommendations for wall
wall ties and sets the density of ties per square ties for timber framed buildings. Information is
metre based on the declared value of the tie, provided for the type of structure, location,
the material factor and the design wind load. embedment, density and positioning. These
BS EN 845-1: 2003 Specification for ties are classified as Types 5 to 7; minimum
Ancillary Components for Masonry – declared values in tension and compression
Part 1: Ties, Tension Straps, Hangers and are listed for Types 5 and 6.
Brackets Although BS 5268 was officially withdrawn on
This European Standard specifies the the full implementation of Eurocodes in March
requirements for wall ties used for 2010, timber frame wall ties should continue to
interconnecting masonry and for connecting be selected from Types 5 to 7 as given in
masonry to beams, columns or other parts Annex B of BS 5268 Part 6.1: 1996, until
of the building. Materials, tolerances, tie further guidance is made available.
variations and the requirements for declared
values, are all covered in this standard. For tie
Types and qualifying criteria refer to PD 6697:
2010.

PD 6697: 2010 Recommendations for the


design of masonry structures to BS EN
1996-1-1 and BS EN 1996-2
Published Document 6697 contains non-
contradictory, complementary information
from the withdrawn British Standard BS 5628,
which was not included in the BS EN 1996
series.
It includes recommendations on tie lengths,
embedment, density, material and positioning.
Masonry-to-masonry ties are classified as
© Aston Homes

Types 1 to 4; the relevant classification is


© Irvine Whitlock

determined by strength, function and use.


Minimum declared values for tension and
compression are listed on page 5 for each tie Ancon TeploTie Wall Ties
Type.
Wind Code Variations
Approved Document E: Resistance to the Masonry wall ties should be selected from the
Passage of Sound Types in PD 6697 and timber frame wall ties
This document specifies the acoustic should be selected from the Types in BS 5268.
performance requirements of ties suitable for These two documents use different Wind
use in separating walls (Type A) and external Codes.
walls (Type B) of new build dwellings.
The maximum wind speeds referred to in PD
Type A ties must have a measured dynamic 6697 are based on ten minute return periods
stiffness of <4.8MN/m3 for the specified according to the current Wind Code BS EN
minimum cavity, at a standard density. Type A 1991-1-4: 2005.
ties in this literature are indicated by this logo
The geographical locations in BS 5268-6.1 are
© Green Building Store

e.g. Staifix HRT4, page 8.


based on hourly return period wind speeds
according to BS 6399-2: 1997.

All Ancon ties which cross a cavity meet the Wall tie Types and the appropriate wind speed
4 requirements of Type B. maps are shown on page 5.
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

Minimum Requirements for Wall Ties to PD 6697: 2010 (Table 12) and BS 5268-6.1: 1996 (Annex B)
Type Minimum Mortar Tensile Load Compressive Load
of Tie Class and Designation Capacity (N) Capacity (N)
M12 (i) 5000 5000
1 M2 (iv) 2500 2500
2 M2 (iv) 1800 1300
3 M2 (iv) 1100 800
4 M2 (iv) 650 450
5 M4 (iii) 600 425
6 M4 (iii) 630 440
7 M4 (iii) To be declared by the Wall Tie Manufacturer

Masonry-to-Masonry Wall Tie Types to PD 6697: 2010


Maximum Building ≤ 31m/s
Type Application Density Height Geographical Location
Type 1 Heavy duty tie suitable for most 2.5 ties/m2 Any Height Suitable for most sites. However, for
building sizes and types. 3-4 ties/m2 relatively tall or unusually shaped buildings
Not very flexible and not at unbonded in vulnerable areas, the tie provision
recommended for applications where edges should be calculated
there is expected to be excessive
differential movement between leaves
Type 2 General purpose tie for domestic and As Type 1 15m Suitable for flat sites where the basic
small commercial buildings. wind speed is up to 31m/s and altitude
is not more than 150m above sea level
Type 2 ties are suitable for use outside the parameters stated e.g. sites over 150m above sea level, buildings exceeding 15 metres etc,
if shown to be adequate by calculation. Contact Ancon for more information. ≤ 27m/s
Type 3 Basic wall tie generally as As Type 1 15m Suitable for flat sites where the basic
Type 2 above wind speed is up to 27m/s and altitude
is not more than 150m above sea level
Type 4 Light duty wall tie suitable for As Type 1 10m Suitable for flat sites in towns and cities
box-form domestic dwellings where the basic wind speed does not
with leaves of similar thickness exceed 27m/s and altitude is not more Wind speed information taken from
than 150m above sea level BS EN 1991-1-4: 2005 for use with
PD 6697: 2010.
Note: Refer to PD 6697: 2010 and BS EN 1991-1-4: 2005 for complete information.

Ancon Teplo4
(Type 4)

Ancon ST1
(Type 1)
Ancon Teplo2
Staifix RT3 Staifix HRT4 (Type 4)
Staifix RT2 (Type 3) Ancon Teplo1 (Type 2)
Suitable for use in internal
(Type 2) separating walls to (Type 1)
Approved Document E

Staifix STF6
(Type 6)
Staifix-Thor
Helical TIM6
(Type 6) Ancon Timber Frame
Movement Tie, TFMT7
(Type 7) ≤ 31m/s

Masonry-to-Timber Tie Types to BS 5268-6.1: 1996 ≤ 31m/s


Maximum Building
Type Application Density Height Geographical Location
Type 5 Timber frame tie suitable for 4.4 ties/m2 15m Suitable for flat sites in towns and cities
domestic houses and industrial/ 3-4 ties/m where the basic wind speed does not
commercial developments of up at unbonded exceed 25m/s and altitude is not more
to three storeys edges than 150m above sea level ≤ 25m/s
Type 6 As Type 5 but suitable for As Type 5 15m Suitable for flat sites in towns and cities
developments of up to four where the basic wind speed does not
storeys exceed 25m/s and altitude is not more
than 150m above sea level
Type 7 As Type 5 but suitable for Calculated for 18m Calculated for actual performance Wind speed information taken from
developments of between five actual required for each site location BS 6399-2: 1997 Code of Practice for
and seven storeys, being performance Wind Loads for use with BS 5268-6.1: 1996.
designed to accommodate required for
the increased vertical each site location
differential movement
Note: Refer to BS 5268-6.1: 1996 and BS 6399-2: 1997 for complete information.
5
Wall Ties and Restraint Fixings

Density & Positioning of Ties


PD 6697: 2010 recommends that for walls in
which both leaves are 90mm or thicker, ties
should be used at not less than 2.5 per square
metre (900mm horizontal x 450mm vertical
centres). Ties should be evenly distributed over
the wall area, except around openings, and
should preferably be staggered.
At vertical edges of an opening, unreturned or
unbonded edges, and vertical expansion
joints, additional ties should be used at a rate
of one per 300mm height, located not more
than 225mm from the edge.
A typical layout is shown below. Various details
incorporating debonding ties at vertical
movement joints are shown on page 17.

Typical Layout of Wall Ties Indicating Maximum Spacing


450-900mm
Vertical movement joint Horizontal movement joint Head restraints
at centres to suit wind
loading
Vertical movement joint

225mm

450mm
450mm

300mm 225mm
300mm
Usually Usually 225mm to
225mm to suit block courses 450mm
suit block
courses
Debonded ties
450mm

See typical detail at


vertical movement joint
225 225 225 900mm 225 on page 17
mm mm mm mm
Standard spacing for cavity brickwork 900mm x 450mm centres in a staggered pattern (2.5 ties per square metre)

Length of Tie & Embedment Recommended Lengths of


Wall ties should be of the correct length to Masonry / Masonry Wall Ties
ensure they are properly embedded in the Cavity Length of Available
Width (mm) Wall Tie (mm) Wall Tie
masonry. The tie should have a minimum
50-75 200 HRT4/RT2/RT3/ST1/Teplo
embedment of 50mm in each leaf but also 76-100 225 HRT4/RT2/RT3/ST1/Teplo
take site tolerances into account for both 101-125 250 HRT4/RT2/RT3/ST1/Teplo
cavity width and centring of the tie. For this 126-150 275 HRT4/ST1/DT/Teplo1/Teplo2
reason Ancon suggests tie lengths which 151-175 300 ST1/Teplo2/DT/Two-Part Tie
achieve an embedment of between 62.5mm 176-200 325* Teplo2/Two-Part Tie
201-225 350* Teplo2/Two-Part Tie
and 75mm.
226-250 375* Teplo2/Two-Part Tie
Embedment Cavity width Embedment
Recommended lengths to suit various cavity 251-275 400* Teplo2/Two-Part Tie
widths are shown in the table for masonry-to- 276-300 425* Teplo2/Two-Part Tie
Embedment of Wall Ties
masonry wall ties. * Lengths for Teplo 2. For the Two-Part Tie refer to page 10

6
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

INSTALLATION GUIDANCE To reduce the risk of injury, Ancon’s stainless


Wall ties are important to the stability of steel wall ties feature rounded safety ends and
masonry and failure to install them correctly Ancon TeploTie wall ties are supplied with
may lead to damp penetration, cracking or bright plastic end caps. These end caps
even the collapse of walls. should be applied loosely to the outer end of a
Wall ties should be pressed down in fresh TeploTie as work on the first leaf progresses
Wall ties should be pressed down in,
mortar. They should be surrounded by mortar and must be removed before the tie is built
and then surrounded by, fresh mortar.
and not simply positioned directly onto into the second leaf.
masonry with mortar placed around them. Ancon recommends both leaves of a cavity
Ideally, ties should be installed with a slight fall wall are built simultaneously to eliminate any
to the outer leaf, not towards the inner leaf as risk of injury from protruding ties.
this could provide a path for moisture to cross
the cavity.
The drip part of the tie should point downward To ensure cavity wall ties are effective at
and be positioned near the centre of the open tying the leaves together they should be
cavity. Ties with multiple drips, like the Staifix installed as the inner leaf is constructed
RT2, can often be positioned centrally as part Staifix Safety End and not simply pushed into a joint.
of the drip will normally be near the centre of
the open section of a partial fill cavity. ‘O rings’
as used on the TeploTie should be moved
along the shank to the open cavity.
Installed ties should be clear of mortar
droppings to allow the drip to function and Ancon Spread Safety End
prevent water from crossing to the inner leaf Ancon frame ties and channel ties are Ties should be installed with a slight fall
of masonry. manufactured with a non-spread safety end to the outer leaf, never towards the inner
The practice of bending up installed wire ties allowing the use of a debonding sleeve. This leaf as this could provide a path for
should be discouraged. This can adversely type of safety end reduces the variety of ties moisture to cross the cavity.
affect the performance of the tie and weaken required on site.
the embedment in the inner leaf. Rigid ties like
the Ancon SD1 and ST1 should never be bent
on site.
To ensure cavity wall ties are effective at tying
the leaves together they should be installed as
Ancon Non-Spread Safety End
the inner leaf is constructed and not simply
pushed into a joint. There is a risk of injury if
wall ties are left protruding from a single wall
leaf before the second leaf is constructed. Site
managers should make all workers and visitors
aware of this risk.

Wall Ties with Insulation


Retaining Clips

7
Wall Ties and Restraint Fixings

WALL TIES TO PD 6697 FOR


BRICK-TO-BLOCK CONSTRUCTION
Ancon ST1 Type 1 Tie
(Masonry Heavy Duty)
The Ancon ST1 is suitable for cavities from
50mm to 175mm and can be used for all
types of buildings of any height, anywhere in
Ancon ST1, Stainless Steel
the British Isles. The section that spans the 200 mm for 50-75mm cavities
cavity has a series of holes to provide water 225 mm for 76-100mm cavities
drips. The ST1 has a measured dynamic 250 mm for 101-125mm cavities
275mm for 126-150mm cavities
stiffness of <113MN/m3 that meets the 300 mm for 151-175mm cavities
performance requirement of Approved
Document E for use in external masonry walls.
For internal separating walls of new-build U.K. Patent Nos. 2 255 358
2 260 348
attached dwellings see HRT4. 2 260 349
Staifix RT2 Type 2 Tie
(Masonry General Purpose)
The Staifix RT2 is a general purpose tie. It is
suitable for cavities from 50mm to 125mm and
can be used for domestic houses and small
commercial buildings up to 15 metres in height
(see page 5 for geographical restrictions). In
many cases, Staifix RT2 wall ties can be used
in buildings greater than 15 metres if shown to
be adequate by calculation. For further
information please contact Ancon’s Technical
Services Team. The Staifix RT2 has BBA
approval and meets the technical requirements
of the NHBC. The RT2 has a measured Staifix RT2, Stainless Steel
dynamic stiffness of <113MN/m3 that meets 200 mm for 50-75mm cavities
225 mm for 76-100mm cavities
the performance requirement of Approved 250 mm for 101-125mm cavities
Document E for use in external masonry walls.
For internal separating walls of new-build
Patent Nos. GB 2359831
attached dwellings see HRT4. IE 83574

Staifix RT3 Type 3 Tie


(Masonry Basic)
The Staifix RT3 is available in 200, 225 and
250mm lengths. It is suitable for some
domestic and small commercial
developments. See page 5 for more details.
Staifix HRT4 Type 4 / Type A Tie
(Masonry Light Duty)
The Staifix HRT4 is available for cavities from
50mm to 150mm. As a Type 4 tie it is suitable
for use in external walls of domestic houses up
to 10 metres in height (see page 5 for
geographical restrictions).
Staifix HRT4, Stainless Steel
The HRT4 is also a Type A tie for separating 200 mm for 50-75mm cavities
225 mm for 76-100mm cavities
walls of any height. Independent tests have 250mm for 101-125mm cavities
proven the Staifix HRT4 has a measured 275mm for 126-150mm cavities
dynamic stiffness of <4.8MN/m3 at a cavity of
50-100mm and 125-150mm and is therefore Patent Nos. GB 2359831
suitable for internal separating (party) walls of IE 83574
new-build attached dwellings with these
cavities. The HRT4 can be used with all
approved robust details for cavity masonry
separating walls, whether traditional or
thin-joint blockwork. Use of these details
eliminates the need for pre-completion
sound testing.
The Staifix HRT4 has BBA approval and meets
8
the technical requirements of the NHBC.
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

Ancon TeploTie Ancon Teplo1, Basalt-Fibre


200mm for 50-75mm cavities
The Ancon TeploTie is suitable for cavities from 225mm for 76-100mm cavities
50mm to 300mm and is manufactured from 250mm for 101-125mm cavities
275mm for 126-150mm cavities
pultruded basalt fibres set in an epoxy resin.
This material has a thermal conductivity of only Ancon Teplo2, Basalt-Fibre
200mm for 50-75mm cavities
0.7W/mK which can be shown in U-value 225mm for 76-100mm cavities
calculations to reduce insulation thickness and 250mm for 101-125mm cavities
wall footprint. A sand finish provides excellent 275mm for 126-150mm cavities
300mm for 151-175mm cavities
mortar key. 325mm for 176-200mm cavities
350mm for 201-225mm cavities
The Ancon range of TeploTies comprises 375mm for 226-250mm cavities
Teplo1 (Type 1), Teplo2 (Type 2) and Teplo4 400mm for 251-275mm cavities
425mm for 276-300mm cavities
(Type 4). Please refer to page 5 for further
details on the suitability of each wall tie. Due Ancon Teplo4, Basalt-Fibre
200mm for 50-75mm cavities
only to the testing completed to date, the use 225mm for 76-100mm cavities
of Type 1 TeploTies is restricted to buildings up 250mm for 101-125mm cavities

to 18m in height. Contact Ancon for the latest


information on this test programme.

Ancon TeploTies have BBA approval and meet


the technical requirements of the NHBC. They Ancon Teplo4
also meet the performance requirement of (Type 4)
Approved Document E for use in external
masonry walls. For internal separating walls
Ancon Teplo2
of new-build attached dwellings see HRT4. (Type 2)
The TeploTie is exclusive to Ancon in the UK
and Ireland. It has already been used on many
ultra energy efficient buildings including the first
Ancon Teplo1
certified PassivHaus to be built with traditional
(Type 1)
masonry cavity walls and the first retrofit to be
built to Level 6 (Zero Carbon) of the Code for Cross-Sectional Areas and Thermal Conductivity of Ancon Wall Ties
Sustainable Homes. Thermal
Tie Reference Tie Length Cavity Width Tie Type to Area Conductivity*
(mm) (mm) PD 6697 (mm2) (W/mk)
TeploTies can be resin-fixed in remedial and
200 50-75 1 19.5 17
retrofit applications. Further details are shown 225 76-100 1 19.5 17
on page 29-30. ST1 250 101-125 1 19.5 17
275 126-150 1 23.4 17
Low Thermal Conductivity Wall Ties 300 151-175 1 23.4 17
Wall ties are an essential element in the 200 50-75 2 7.5 17
RT2 225 76-100 2 7.5 17
strength and stability of cavity walls, but by 250 101-125 2 8.6 17
crossing the cavity they act as a thermal 200 50-75 3 6.2 17
bridge between the internal and external RT3 225 76-100 3 6.2 17
250 101-125 3 7.5 17
leaves. The ties featured here on pages 8-9
200 50-75 4 3.5 17
form Ancon’s Low Thermal Conductivity range; HRT4 225 76-100 4 4.2 17
ties which minimise heat loss and improve the 250 101-125 4 6.2 17
275 126-150 4 6.2 17
energy-efficiency of a masonry wall. The effect
200 50-75 1 38.5 0.7
Ancon’s high tensile wire wall ties have on heat Teplo1 225 76-100 1 38.5 0.7
transfer is negligible and, with a thermal 250 101-125 1 38.5 0.7
275 126-150 1 38.5 0.7
conductivity of only 0.7W/mK, the Ancon
200 50-75 2 19.6 0.7
TeploTie is the most thermally-efficient wall tie 225 76-100 2 19.6 0.7
on the market. 250 101-125 2 19.6 0.7
275 126-150 2 28.3 0.7
For the accurate calculation of a wall’s U-value Teplo2 300 151-175 2 28.3 0.7
it is important to use the correct information for 325 176-200 2 28.3 0.7
350 201-225 2 38.5 0.7
the wall ties. Using the actual cross-sectional
375 226-250 2 38.5 0.7
area and thermal conductivity value of a wall 400 251-275 2 38.5 0.7
tie, rather than allowing a program to apply 425 276-300 2 38.5 0.7
default values, can make a considerable 200 50-75 4 12.6 0.7
Teplo4 225 76-100 4 12.6 0.7
difference to the calculated U-value. Default 250 101-125 4 12.6 0.7
values will over-estimate the effect of an Ancon Note: BS EN ISO 6946 permits the corrections due to wall ties, air gaps etc to be omitted, if the corrections amount to
Wall Tie. less than 3% of the uncorrected U-value of the element. * Wall Ties with a thermal conductivity of less than 1.0W/mK are
excluded from U-value calculations to EN ISO 6946, irrespective of cross-sectional area.

9
Wall Ties and Restraint Fixings

TIES FOR CAVITIES OVER 150MM


Ancon Two-Part Tie
Cavities exceeding 150mm are sometimes
required. This necessitates longer ties which
can be difficult to balance and keep horizontal
when built into the inner leaf. Alternatively, the
Ancon Two-Part Tie has one section built into
the blockwork; the other section is then fixed
as the outer leaf is built. An embedment of
75mm is required at each end. The inner tie is
usually manufactured in lengths of 170mm
with variation in the cavity width being
accommodated by the length of the outer
section. Where insulation thickness is in
excess of 60mm, the inner section should be
longer than the standard 170mm to ensure the
connection between the two parts is made in
the open cavity.
Ancon Two-Part Ties sustain loads which
exceed the requirements for a Type 2 tie to Inner Section
PD 6697 for cavities up to 300mm. Type 2
performance can be achieved for wider
170mm
cavities providing the fixing centres are as standard
adjusted in accordance with the table below.
To specify or order this tie simply quote ‘Ancon
U.K. Patent No.
Two-Part Tie to suit _ _ _mm cavity with an Outer Section 2 265 920
insulation thickness of _ _ _mm’. The black TJ
Insulation Retaining Clip is recommended for
Length to suit
use with the inner section. application
Recommended Fixing Centres for
Two-Part Ties
Cavity Vertical Horizontal Connection to
(mm) centres (mm) centres (mm) be made in the
150-300 450 900 open cavity
301-333 450 750
334-367 450 600
75mm Insulation 75mm
368-400 450 450
Depth

Cavity
Ancon TeploTie
Ancon Teplo2 (Type 2) wall ties are available to
suit cavities up to 300mm. They have a ANCON SLIP-BRICK TIES
thermal conductivity of only 0.7W/mK, are Ancon Slip-Brick Ties are
BBA approved and meet the technical bolted directly to blockwork or
requirements of the NHBC. These ties are concrete to give both support
suitable for use with partial-fill and full-fill and restraint to thin slip brick
cavities. facings.
In addition to the standard
Wall Tie PD 6697 Length Cavity Range
Reference Type (mm) (mm) three brick version, slip brick
Teplo2 2 200 50-75 ties can be manufactured in
Teplo2 2 225 76-100
other multiples on request.
Teplo2 2 250 101-125
Teplo2 2 275 126-150
Teplo2 2 300 151-175
Teplo2 2 325 176-200
Teplo2 2 350 201-225
Teplo2 2 375 226-250
Teplo2 2 400 251-275
Teplo2 2 425 276-300

10
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

TIES FOR STEEL STUDWORK


Ancon 25/14 Restraint System
The Ancon 25/14 system is designed to tie
brickwork to steel studding. Self-drilling screws
fix through the channel and the rigid insulation
board, into the steel. Once the channel is
installed, Ancon SD25 wall ties can be
positioned at any point along its length and are
built into the bed joints of the outer leaf of
brickwork.
The spacing of ties is based on the height of
the building and its geographical location.
This system has a performance in excess of
Type 3 and the table below should be used in
conjunction with the first wind speed map on
page 5.
Tie Spacing Based on 25/14 Channel at
600mm Horizontal Centres with Basic Wind
Speed < 27m/s
Vertical Tie Spacing
(mm) for Various
Altitude and Distance Heights of Brickwork
from the Coast 15m 25m 40m
Altitude up to 150m and at
least 50km from coast 450 225 225
Altitude up to 25m and within
50km from coast 450 300 225

Ancon recommends that wall ties achieve a


minimum embedment of 62.5mm in the outer
leaf of brickwork. Applications with a 50mm
open cavity require 100mm long ties.
25/14 channel is available in lengths of
2700mm and 3000mm. It features pre-
punched holes at close centres to ensure a
fixing position is always located near the end,
even when it is cut on site. It should be fixed
to steel studwork at 450mm vertical centres.

14mm

16mm
25mm

25/14 Channel Profile

Screws are available to accommodate an Ancon 25/14 Channel


with SD25 Wall Tie
insulation thickness of up to 115mm. Ancon
recommends the use of stainless steel fixing
screws.
The channel has a 16mm opening to
easily accommodate a drive socket and
washer for the fixing screws.
This system has been independently tested at
Self-Drilling Screw Ref. HTSS-65-2PT HTSS-82-2PT HTSS-115-2PT HTSS-135-2PT
CERAM Building Technology and meets the
Material Stainless Steel Stainless Steel Stainless Steel Stainless Steel
technical requirements of the NHBC.
Diameter (mm) 5.5 5.5 5.5 5.5
Note: This system is unsuitable for use with flexible or Length (mm) 65 82 115 135
semi-rigid insulations. Contact Ancon for further
information. Insulation Thickness (mm) 35-50 50-70 70-95 95-115

11
Wall Ties and Restraint Fixings

TIES FOR THIN-JOINT BLOCKWORK TJ2 to PD 6697


Staifix-Thor Helical TJ2 Wall Tie Block Strength Tie Type to PD 6697
N/mm2 50, 75, 100mm Cavity 125, 150mm Cavity
The TJ2 wall tie hammers directly into aerated
2.8 4 4
concrete blocks, through insulation material,
3.5 - 4.0 3 4
and is built into the bed joints of the outer leaf
7.0 - 10.5 2 3
of brickwork. It is ideal for thin-joint blockwork
and other applications where the joints in the Note: For maximum building height and restrictions based on geographical location please refer to page 5.
inner and outer leaves are not aligned. This tie
meets the requirements of the NHBC and
PD 6697 as a type 2, 3 or 4 wall tie depending
on the block used and the cavity width. Tools
are available to simplify installation.
The helix of the Staifix-Thor Helical range is
superior to other helical fixings. Each rotation 85mm 70mm
interlocks perfectly down its length
guaranteeing maximum performance.
The black Staifix TJ Clip is designed for use
with TJ2 wall ties.
Embedment Depths
Staifix HRT4 Wall Tie
For thin-joint to thin-joint separating walls use TJ2 Recommended Lengths
the Staifix HRT4 (see page 8). Cavity Width (mm) Tie Length (mm)
50 205
Staifix-Thor Helical TJ2 Thin-Joint Tie
European Patent No. 1307303 75 230
100 255
Ties for Cellular Clay Blocks 125 280
Ancon has developed an innovative range of 150 305
wall ties for use with cellular clay blockwork,
where the horizontal bed joints are just 1mm.
The range includes cavity wall ties for use with
external brickwork, cavity wall ties for internal
separating walls to Approved Document E and CCB3-100
ties for connecting perimeter walls to internal
CCB3-125
walls.
Installation of the component parts of cavity CCB4-150
wall ties in this range are phased which CCBA-75
CCB-IWJ-180
eliminates any danger of injury from wall ties
projecting from a part-built cavity wall.

Cellular Clay Block to Traditional Masonry

Cavity Width Product Type 4 Type 3 Type 2


(mm) Reference Performance Performance Performance
Horizontal x Vertical Spacings (mm)
100 CCB3-100 900 x 450 900 x 450 600 x 450
125 CCB3-125 900 x 450 900 x 450 600 x 450
150 CCB4-150 900 x 450 450 x 450 -
Notes: At vertical edges of an opening, unreturned or unbonded edges, additional ties should be used at a rate of one
per 300mm height, located not more than 225mm from the edge. For complete information on tie types refer to
PD6697: 2010. Tested to EN845-1:2003.

Ancon CCB3 Wall Tie


Cellular Clay Block to Cellular Clay Block Patent pending
for Internal Separating (Party) Walls
Cavity Width Product Horizontal x Vertical
(mm) Reference Spacings (mm)
75 CCBA-75 900 x 450
Note: Type A tie suitable for use in internal separating
walls of any height to Approved Document E: Resistance
to the Passage of Sound.

Flat Tie for connecting perimeter walls to


internal walls
Product Reference Length (mm)
CCB-IWJ-180 180
Ties for Internal Wall Junctions Note: For block widths greater than 140mm, two ties
should be used per course.
12
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

TIES FOR BUBBLE FOIL INSULATION Bubble foil insulation Insulation retaining
clip
A range of ties are manufactured under license
Multiple drips
from Thermal Economics Ltd for use with
Bubble Foil Insulation. These ties have been
designed to PD 6697 and are available as Type
2 and Type 4 ties. ITB referenced ties enable
the insulation material to be installed flush to the
blockwork. ITC referenced ties position the
insulation 25mm away from the block. These
ties meet the technical requirements of the
NHBC.

Wall Tie PD 6697 Length Cavity Range


Reference Type (mm) (mm) Embedment Cavity width Embedment
TE-ITB4-185 4 185 50-60
Installation of Staifix TE-ITC2 Wall Ties Staifix TE-ITB2 Wall Ties shown with
TE-ITB4-200 4 200 60-75
Alreflex Ultratherm
TE-ITB4-225 4 225 85-100
TE-ITC4-200 4 200 60-75
TE-ITC4-225 4 225 85-100
TE-ITB2-185 2 185 50-60
TE-ITB2-200 2 200 60-75
TE-ITB2-225 2 225 85-100
TE-ITC2-200 2 200 60-75 Staifix TE-ITB4 *
TE-ITC2-225 2 225 85-100 *Lengths 185, 200mm Staifix TE-ITC2
Note: Refer to page 5 for more information on Type 4
and Type 2 ties.

TIES FOR TIMBER FRAMES Staifix-Thor Helical Timber Tie, TIM6 (Type 6) Ancon Timber Frame Movement Tie,
Ancon manufactures two Type 6 Timber Frame The Staifix-Thor Helical TIM6 is available in four TFMT7 (Type 7)
Ties designed to fix brickwork or blockwork to standard lengths. It is suitable for cavities from Where standard Type 6 Timber Frame Ties are
timber-framed structures up to 4 storeys in 50mm to 150mm and can be used with the red unsuitable, Ancon recommends the use of the
height and accommodate maximum differential Staifix Universal Clip where insulation has to be Timber Frame Movement Tie. Manufactured to
movement of 24mm. retained in the cavity. An installation tool is suit any cavity from 50mm to 150mm, the
required to hammer the tie into the timber Ancon Timber Frame Movement Tie comprises
Staifix Timber Frame Tie, STF6 (Type 6)
frame. a channel, a strip tie and a screw. This system
The Staifix STF6 tie is available in three lengths
to suit 50mm, 75mm and 100mm cavities. It is TIM6 Recommended Lengths accommodates maximum differential
supplied complete with an annular ring shank movement of 65mm; the tie should be
Tie Length Cavity Width BS 5268
nail. The tie is cranked to simplify correct positioned 10-12mm from the bottom of the
(mm) (mm) Type
installation and to prevent moisture from channel.
175 50-60 5
crossing the cavity. 175 61-75 6 The TFMT complies with BS 5268-6.1 as a
The Staifix STF6 tie has been independently 200 76-100 6 Type 7 tie. The product has a design
tested for use with 15mm OSB (Oriented Strand 225 101-125 6
resistance of 270N which should be used in
Board) SIPS Panel. The standard annular ring conjunction with a factored wind load. See
250 126-150 6
shank nail should be replaced with a 4 x 30mm page 5 for more information on Type 7 ties.
stainless steel Spax® screw.

Staifix STF6 Timber Frame Tie Staifix-Thor Helical TIM6 Tie Ancon TFMT7 Timber Frame Movement Tie
Available to suit 50mm, 75mm and 100mm cavities.

13
Wall Ties and Restraint Fixings

FRAME CRAMPS AND CHANNEL TIES


Frame cramps can be fixed to concrete, SDB Wall Tie
steelwork or masonry and have a single 7mm
1000
diameter hole or an 8mm x 30mm vertical slot.
900
Ancon M6 Single Expansion bolts are 800
recommended for fixing to concrete, set 700
screws or self-drilling screws for steelwork, 90mm 600
N
and suitable plugs and screws for fixing to 500
SDV Wall Tie 400
masonry.
300
Poor substrates will limit the capacity of frame 200
cramps and site testing may be advisable in 100
some cases. The performance will also be 0
SDV SDV SDV
determined by the position of the fixing. SDV Fixing at Fixing in Fixing at
ties fixed to steelwork or concrete at the 90mm bottom of slot centre of slot top of slot
lowest point of the slot will have a safe working
Recommended Safe Working Loads for 20 x 2.5mm Section Frame Cramps
load of approximately 1kN. The capacity will
reduce as the fixing is moved further away Recommended Lengths of Frame Cramps and Cast-in Channel Ties
from the bend and greater movement must be Cavity Width (mm) Length of Wall Tie (mm) Frame Cramp/Channel Tie
expected than with other types of wall tie. 20-44 100 SPB/SP21
Ancon SDB Frame Cramps have a safe 45-69 125 SDB/SD21
70-94 150 SDB/SD21
working load of approximately 500N,
95-119 175 SDB SD21
comparable to the load of an SDV when fixed 120-144 200 SDB/SD21
in the centre of the slot. 145-169 225 SDB/SD21
Note: This table excludes Ancon Fastrack and Ancon 25/14 Channels. Frame cramps should have a minimum embedment of
Thermal Break 50mm in the outer leaf. Taking site tolerances into account, Ancon suggests tie lengths which achieve a greater embedment.
Ancon Frame Cramps can now be supplied
with Thermal Breaks to be located between 20mm 3mm

the upstand and the structural frame. They are


manufactured from a durable fibre-reinforced
thermoset plastic which has a thermal 7mm ø
30mm
conductivity of just 0.3 W/mK.

Frame Cramp Thermal Break


Embedment

90mm
Length
SDB Wall Tie Fixed to Steel
with Self-Drilling Screw

Embedment

90mm
Length
SD21 Wall Tie Fixed into 21/18
Omega Channel

14
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

Isolation PRE-FIXING AIDS


Ancon isolation sleeves and pads are supplied The practice of pre-fixing frame cramps in
blank for use with self-drilling screws to isolate advance of masonry can accelerate the
stainless steel frame cramps from mild steel. speed of construction and provides an
Self-adhesive isolation pads are also available opportunity to check that wall restraints
for _ _B (20 x 30mm) and _ _ V (25 x 50mm) have been located correctly and are
referenced frame cramps. securely fixed.
Isolation Sleeve Adhesive Isolation Pad
Ancon Gauge Tape
SPA Frame Cramp (Pre-fix Patent 2 256 223)
Where masonry is in line with a column flange, Gauge Tape illustrates the standard 225mm
Length to suit brick/block gauge and the fixing position of
frame cramps can be supplied with an offset application
angle section instead of an upstand. This frame cramps. It is applied directly to the
angle allows the mechanical fixing to be structural frame (steel, concrete, timber or
suitably located. These ties are referenced masonry) to facilitate the pre-fixing of frame
SPA. They feature a 7mm hole as standard cramps and to maintain accurate masonry
and can be used with a debonding sleeve if coursing.
Angle to suit
required at a movement joint. The thickness, application Ancon ISO-TW Washer
size and shape of the angle section are The ISO-TW washer enables Ancon slot-
designed to suit each application. Contact ended frame cramps to be vertically
Ancon’s Technical Department for more adjusted within the 30mm range of the slot
information. SPA Frame Cramp to suit the exact location of mortar joints
without affecting the integrity of the fixing.
Ancon SPA frame cramp at In addition, this washer prevents bi-metallic
450mm vertical centres corrosion by separating the frame cramp
from the structural frame and fixing screw.

SPA Frame Cramp Fixed to Steel with


M6 Isolated Set Screws
Ancon ISO-TW and Gauge Tape

Ancon HiT - Hammer-in Tie


The Ancon HiT fixes masonry to concrete,
dense blocks (>_7N/mm2), non-perforated brick
or hard stone. It can reduce the variety of tie
lengths required on site and speed the rate of
construction.
The HiT is available in a standard length of
310mm that is bent on site with a special
installation tool to suit all cavities up to
150mm. Unlike conventional frame cramps it
does not require a mechanical fixing, but is
hammered into a plug.
The Ancon HiT meets the requirements of
PD 6697 as a Type 2 tie. A neoprene 'O' ring
must be installed on the tie to prevent moisture
crossing the cavity.

Ancon Hammer-in Tie (310mm)

15
Wall Ties and Restraint Fixings

Ancon 21/18 Omega Channel Ancon 25/14, 28/15, 30/20, 38/17, 36/8 and
Ancon 21/18 Omega Channel is a high 40/25 Channels
performance, self-anchoring, cast-in channel Ancon wall ties can also be used with our
slot suitable for use with Ancon wall ties to 25/14, 28/15, 30/20, 38/17, 36/8 and 40/25
provide the necessary restraint to the outer leaf channels. 30/20 Channel is supplied with
of masonry. The section is only 18mm deep anchors for casting into concrete. 25/14 and
and can be used where there is reduced cover 36/8 Channels are supplied plain-backed for
to reinforcement. Available in 100mm and surface fixing. 28/15, 38/17 and 40/25
3000mm lengths, Ancon 21/18 Omega Channels are available with or without anchors
Channel is filled with polystyrene to help for casting in or surface fixing. Ties for 38/17
prevent the ingress of concrete. Nail holes aid and 40/25 channel will be 25mm wide to
the fixing of the slot to timber formwork. Wall accommodate the wider opening; all other
ties used with Ancon 21/18 Omega Channel channel ties will be 20mm wide. Wall ties used
will provide safe working shear and tensile with Ancon 28/15, 30/20, 38/17 and 40/25
loads of 1.5kN. channel will provide safe working shear and
tensile loads of up to 1.0kN, while wall ties
used with 25/14 and 36/8 channels will provide
up to 0.5kN. Maximum safe working loads of
surface-fixed channels will be subject to
suitable fixings, and appropriate fixing centres.
Fixing of Channel
Available Lengths of Ancon 21/18 Omega Channel
100, 3000 mm Fixing Method Omega 21/18 25/14 28/15 30/20 38/17 36/8 40/25
U.K Patent No. 2 249 110 Cast-in       
Surface Fixed       
Ancon 21/18 Omega Channel with Ancon
SD21 Tie
Maximum Centres for Surface-Fixing
SWL (tension) 25/14 28/15 38/17 36/8 40/25
0.5kN 337 525 650 300 650
1.0kN - 400 525 - 525

Fastrack used with DD28 Tie for Stonework

Ancon Fastrack Channels 100mm long with SD28 Tie

Ancon Fastrack Ancon Fastrack Channels and Ties can be


Building one leaf of the cavity wall in advance supplied in different lengths and can also be
of the other is often beneficial but can create used for tying stonework to blockwork if DD28
problems with coursing. Buildings which or similar Ancon Ties are used.
incorporate imperial or continental bricks and
The recommended tie length for use with a
standard metric blocks present even greater
fastrack channel is ‘cavity width plus 50mm’.
difficulties.
Ancon Fastrack Channels and Ties sustain
Ancon Fastrack Channel is built into the inner loads which exceed the requirements for a
leaf of blockwork ready to take an Ancon Type 2 tie to PD 6697. This system can also
Fastrack used with SD28 Tie for Brickwork
SD28 or similar tie for the outer leaf. This be manufactured in a 36/8 channel profile that
method of construction avoids the dangers accepts wall ties referenced _ _ 36.
of projecting ties.

16
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

VERTICAL MOVEMENT JOINTS


Debonding sleeves are used on plain-ended Ancon 21/18
wall ties, like the Ancon PP21 or PPB, at Omega channel
vertical movement joints. The tie will restrain
Ancon PP21,
the masonry against lateral wind loads but the
125mm
sleeve will allow the masonry to expand or wall tie with
debonding
contract. Debonding sleeves should be
sleeve
installed with a 10mm gap at the end to allow
for expansion of the masonry.

Ancon PPS Wall Tie with


Debonding Sleeve
225, 250mm

10mm
Gap

Debonding sleeves should be pulled back 10mm to


allow expansion as well as contraction of brickwork

Ancon PPS, 225mm


wall tie with
debonding sleeve

Ancon ST1
wall tie

Intermediate Column with Vertical


Movement Joint in Brickwork and Blockwork

Ancon PP21, 125mm wall Ancon SD21 wall


Ancon ST1 wall tie Ancon PP21, 125mm wall ties with debonding sleeves,
ties with debonding sleeves, ties at 450mm
at 450mm vertical centres
at 450mm vertical centres vertical centres
Ancon ST1
wall tie

Ancon PP21, 125mm


wall ties with debonding
sleeves, at 450mm
vertical centres

450mm 450mm
225mm 225mm

Staifix RT2 wall ties at Ancon PPS, 225mm Intermediate Column with Vertical
450mm vertical centres in wall ties with debonding Movement Joints in Blockwork
alternate courses to Ancon sleeves, at 450mm
PP21 Wall Ties vertical centres
Ancon PPS, 225mm wall ties with debonding
sleeves, at 450mm vertical centres
Intermediate Column with Vertical
450mm to 900mm Movement Joints in both Brickwork and
Blockwork
External Corner with Fully Bonded
Brickwork Ancon ST1
wall tie
Note: All spacings are maximums. The type of cavity wall tie and spacing will be determined by the cavity width, height
of brickwork, wind loading and type of building. See page 5 for further information.
225mm 225mm

Cavity Wall with Vertical Movement Joint


in Brickwork

17
Wall Ties and Restraint Fixings

STANDARD WALL TIES HRT4 SP21


Lengths 200, 225, 250 , 275mm Lengths 75, 100, 125, 150,
Lengths shown in red italics refer to items Conforms to PD 6697 as a Type 4 tie 175, 200 mm
normally available at all times. Reasonable Patent Nos. GB 2359831 For use with 21/18
IE 83574 Omega Channel
quantities can be delivered within 24 hours of Length
acceptance of an order.
Suitable for party
walls with 50-100mm
Ancon and Staifix wall ties are also available SD21
and 125-150mm cavities
from builders merchants and other specialist Lengths 125, 150, 175, 200,
225mm
distributors. For further information regarding For use with 21/18
the availability of any fixings or details of your Teplo4 Omega Channel
Lengths 200, 225, 250mm 90mm
nearest stockist, please contact Ancon sales Conforms to PD 6697
staff. as a Type 4 tie

Ancon’s Technical Services Team will be PP21


DT (Double Triangle) Lengths 125, 150, 175, 200,
pleased to advise on the correct selection and Lengths 150 *, 200 *, 225 *, 250 **, 275**, 225 mm
use of our wall ties. 300 **mm For use with 21/18
*Conforms to EN 845-1 and PD 6697 Omega Channel
as a Type 2 tie
ST1
**Conforms to EN 845-1 and SPS
Lengths 200, 225, 250, 275, 300 mm
PD 6697 as a Type 3 tie Lengths 150, 200, 225,
Conforms to PD 6697 as a Type 1 tie
U.K. Patent Nos. 2 255 358, 250, 275, 300 mm
2 260 348 & 2 260 349 (Not suitable for collar-jointed
construction. See below)
Length SPB
Lengths 75, 100, 125, 150,
175, 200 mm
Teplo1 SPS CJ
Lengths 200, 225, 250, 275mm Length Length 150mm
Conforms to PD 6697 as a Type 1 tie. (3mm thickness for
Due to testing completed to collar-jointed construction)
date the use of Type 1 TeploTies
is restricted to buildings SDB
up to 18m Lengths 125, 150, 175, 200,
in height. 225 mm

SD1 90mm PPS


Lengths 225, 250 mm
Lengths 200, 225, 250, 275, 300 mm
Conforms to PD 6697 as a Type 1 tie
Also available with a central drip PPB
Lengths 125, 150, 175, 200,
225 mm
SHX
Lengths 150, 175, 200,
225mm
90mm
SPV
Lengths 75, 100, 125, 150,
RT2 175, 200 mm.
Lengths 200, 225, 250 mm
Conforms to PD 6697 as a Type 2 tie WHX
Patent Nos. GB 2359831 Lengths 150,
IE 83574 175, 200mm

SDV
Lengths 125, 150, 175, 200, Length
225mm

Teplo2 90mm SRB


Lengths 200, 225, 250, 275, 300, 325, 350, Lengths 125, 150,
375, 400, 425mm 175, 200 mm
(Used in applications instead
Conforms to PD 6697 as PPV
a Type 2 tie of the SDB where greater
Lengths 125, 150, 175, 200,
flexibility is required)
225mm

Cavity Starter Tie


Supplied with an 8mm
Recommended Lengths for Recommended Lengths for Frame Cramps nylon wall plug and neoprene ring
Masonry/Masonry Wall Ties and Cast-in Channel Ties* Lengths 180, 200, 220, 230 mm

Cavity Width (mm) Tie Length (mm) Cavity Width (mm) Tie Length (mm)
50-75 200 <20 75
76-100 225 20-44 100 Starter Tie
101-125 250 45-69 125 Supplied with an
126-150 275 8mm nylon wall plug
70-94 150
151-175 300 Length 135 mm
175-200 325 95-119 175
201-225 350 120-144 200
226-250 375 145-169 225 Frame Tie
18 251-275 400 *Excluding Ancon Fastrack Length 130 mm
276-300 425
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

REFERENCES FOR WALL TIES 10


Example using
Many variations are available in addition to the Reference System HEAD
standard ties. Wall ties for special applications 50
30
may be specified and ordered with ease by Head 21
8x30mm slot
using a reference letter for the tail, shank and Shank D 10
head of the tie.
Tail S __V
Ancon ties are produced in lengths from _ _ U without slot
Ancon SD21 10
150mm for masonry-to-masonry ties, and SHANK
wall tie
75mm for masonry-to-concrete ties, in 30
increments of 25mm. Drips will usually be 20
7mm diameter hole
positioned 90mm from the outer end of the tie
TAIL _D_
(first reference letter). Masonry-to-masonry ties Most can be used at
__B
can also be supplied with a central drip. either end of tie
Special wall ties with a section wider than
20mm referenced S_ _, will have an end with
three holes without the side notches. S__
L

_P_ _ _ 21
To fit 21/18
Omega Channel

25mm
L__
L
P__ _V_ _ _ 25 To fit 25/14
_ _ 28 To fit 28/15
_ _ 30 To fit 30/20
_ _ 36 To fit 36/8
L _ _ 38* To fit 38/17
W__ 10mm
_ _ 40* To fit 40/25
D__ *Tie will be 25mm wide
10mm _F_
6x60mm welded
dowel
__X
7mm diameter hole
L

T__ Y__
10mm
6x60mm loose _H_
dowel __G
Manufactured 110mm Tie will be 25mm
to suit wide
15mm
15mm
10mm
M_ _
6.5mm 6x60mm loose
diameter holes dowel

Z__

Insulation Retaining Clips Insulation Retainer Debonding Sleeves


The red Staifix Universal Insulation Retaining The H75/2 Insulation Retainer is for securing Debonded Ties require 100mm embedment.
Clip (Uni) will fit all the standard stainless steel material to concrete, blockwork and brickwork. A 120 mm long sleeve will provide an
ties shown on page 18. The black Teplo-Clip The 90mm diameter head can hold back up to allowance for movement and tolerance, and
should be used with the TeploTie range. The 75mm of insulation. A 10mm diameter hole is will be suitable for most applications. Other
black TJ Clip is suitable for Ancon Two-Part required in the base material. The projecting lengths and sizes available to
Ties and the TJ2 wall tie (see page 12). end of the retainer is pushed through the special order.
insulation material into the hole and tapped
Uni into position to secure the insulation.

Diameter
80mm

100mm
Teplo-Clip
19
Wall Ties and Restraint Fixings

NON-DRILL FIXINGS FOR Hammer-On Section


STEELWORK Available in five sizes to accommodate a steel
Ancon’s range of ‘NON-DRILL’ masonry-to- thickness from 7mm to 25mm, this fixing is
steel fixing solutions was developed to address simply hammered onto the flange. It can be
the safety concerns of the Industry. utilised either on a column with a tie or on a
Driven by customer demand for masonry beam with an internal head restraint.
restraint fixings with an alternate installation Hammer-On Flange
Section Thickness
method from either shot-firing or drilling, Ref Accommodated
Ancon engineered the innovative solutions XS 7-10mm
detailed here. These fixings do not require the S 10-13mm
use of power tools and can reduce installation M 14-17mm
L 18-21mm
times and costs. In all instances they simply
XL 22-25mm
abut the column or attach to the flange to
restrain the wall against lateral wind loads. The Hammer-On Section resists load in
Design Sheets one direction only and should be installed
Contact Ancon on +44 (0) 114 275 5224 or on alternate sides of the flange.
visit www.ancon.co.uk for a Non-Drill Fixings Hammer-On Ties should be installed at
Design Sheet. This sheet summarises all the 225mm vertical centres and Hammer-On Head
information required by Ancon to specify/quote Restraints at 450mm horizontal centres. The
for the most appropriate non-drill fixing to suit wall tie (HOS-TIE) or head restraint (IHR-H)
your application. should be positioned central to the masonry
Ancon NON-DRILL fixings: leaf when located in one of the five fixing slots.
• Eliminate the dangers associated with shot- For more information on the IHR-H Head
firing and drilling Restraint see page 22.
• Quick, simple and economical to install
• No power tools required
• No special skills or equipment required
• Fixings either abut the column or attach to
the flange

Hammer-On Tie Hammer-On Section


Patent No. GB 2424660B
IE 85501

Hammer-On Tie (Debonded HOS-TIE,


pictured above, supplied complete with
Hammer-On Section)

Hammer-On Ties can resist a load of 900N.


When fixed at 225mm vertical centres,
staggered on alternate sides of the column
flange (effective centres 450mm on each side)
the service load will be 2kN per metre in either
direction.

Hammer-On Ties installed to


alternate sides of the column
at 225mm vertical centres

20
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

Internal Column Tie


Available in seven lengths, this tie fits between
the flanges of a column and should be
installed at 225mm vertical centres.
Internal column ties exceed the requirements Length
for a Type 2 tie to PD 6697.
Internal Column Tie
Length Beam/Column
(mm) Accommodated
179 203 x 203 UC
186 203 x 133 UB
224 254 x 254 UC 50mm 50mm
232 254 x 146 UB
275 305 x 305 UC 15mm
281 305 x 127 & 165 UB
330 356 x 127 & 171 UB
15mm
Non-Standard
Non-Standard Internal Column Tie Internal Column Tie
Special internal column ties can be designed to
60mm 40mm
suit applications where the masonry does not
sit inside the flanges of a column. The drawing
Movement joint
provides some guidance on dimensions; 150, 180mm
contact Ancon for more information.
Non-standard internal column ties exceed the 10.0-
13.5mm
requirements for a Type 2 tie to PD 6697.
Briclok A
New Briclok 6.8-10.3mm *
The Briclok fits to a column flange and can be
used either across a cavity or back into the
inner leaf. It should be positioned with the 150, 180mm
appropriate notch around the flange and 450mm 450mm
installed at 225mm vertical centres. The tie 16.5-
must not be forced onto the column and 20.0mm Staifix RT2 Wall Ancon Briclok at
Ties at 450mm 225mm vertical
should have no less than 10mm engagement. vertical centres centres. Can be
Briclok B used in either leaf
Two types (A and B) accommodate a steel 13.5-17.0mm
thickness from 6.8mm to 20mm and are
available in two lengths to suit an open cavity Product Code Length Open Cavity* Flange Thickness
from 20mm to 80mm. Briclok150A 150mm 20-50mm 6.8-13.5mm
Briclok180A 180mm 50-80mm 6.8-13.5mm
Briclok ties exceed the requirements for a
Briclok150B 150mm 20-50mm 13.5-20.0mm
Type 2 tie to PD 6697. Briclok180B 180mm 50-80mm 13.5-20.0mm
Column Tie * Open cavity at column face.

The Column Tie clamps to the flange of a


column. It accommodates a steel thickness
from 6mm to 25mm and should be installed at
225mm vertical centres. Manufactured in
lengths to suit the application, it can feature a
drip for use across the cavity or a plain shank
for installation back into the inner leaf.
Avoiding Bi-Metallic Corrosion Column Tie
Bi-metallic corrosion may occur in a damp
environment where stainless steel fixings are in
contact with a structural steel frame. This will
not affect the stainless steel but may cause
slight surface corrosion to the mild steel. Best
practice is to isolate the two dissimilar metals.
Bitumen paint or some other form of isolation
e.g. adhesive tape, applied at the point of
contact will prevent this corrosion.

21
Wall Ties and Restraint Fixings

50mm
min.
50mm
max.

215mm

Ancon IHR - B Bolted to Concrete,


Restraining Top of Inner Block Wall

ANCON HEAD RESTRAINTS


Ancon Head Restraints provide the necessary
restraint to the top of masonry walls. They
allow for vertical movement to accommodate
shrinkage or thermal movement of the wall or Ancon IHR - B Ancon IHR - V Ancon IHR - H* Ancon IHR - C
structural frame, while restraining wind loads. with Hole with Slot supplied with to suit Cast-in
Hammer-On Channel
Section
IHR - C 38
to suit 38/17
IHR - C 30
to suit 30/20

Ancon IHR-H Hammer-On Head Restraint *The IHR-H can resist a load of 1kN. When fixed at 450mm centres staggered each side of the lower beam flange (effective
centres 900mm on each side) the service load will be 1.1kN per metre in either direction.
Ancon IHR - Internal Head Restraint
The Ancon IHR is used for restraining the top Ancon FHR - Head Restraint
of internal walls or the top of the inner leaf of a The Ancon FHR Head Restraint is used for
cavity wall. The opening at the front of the restraining the top of internal walls or the
channel stem is sealed to prevent mortar internal leaf of a cavity wall. The two angles
ingress and to ensure that vertical movement clamp the top of the wall and have 10mm
can take place between the blockwork and the diameter holes to suit M8 bolts. They are
structure. The base of the stem must be built supplied with two holes in the longer angle to
within a bed joint with the centre of the stem allow the restraint to fit 100mm and 140mm
no closer than 50mm from the edge of the blockwork. Each restraint can resist a service
block. The vertical joint should be filled with
load of 1kN.
mortar each side of the stem. The maximum 25mm
max.
joint between the top of the blockwork and the
underside of the frame is not normally greater
than 25mm. The standard Ancon IHR will suit a 75mm
215mm high block and can resist a load of
1.5kN*. Where the gap at the top increases
from 25mm to 50mm, the working load is Ancon FHR Head Restraint Fixed to
reduced from 1.5kN to 1.0kN. Other sizes Underside of Floor Slab, Restraining Head
between 150 - 250mm are available. of Inner Leaf of Cavity Wall

The sliding tie can be provided with either a hole To suit 100mm and
(IHR - B) or slot (IHR - V) to suit M8 bolts, with a 140mm Blockwork

notch end to fix directly into a 38/17 or 30/20 Ancon FHR Head Restraint - other sizes
cast-in channel (IHR - C) and with a notch end available
to suit the Hammer-On Section (page 20) that
attaches to a steel flange without site drilling
22 (IHR - H).
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

SAH - T SAH - U SAH - UF


35mm min. 45mm
38mm
Supplied
38mm
as standard. 25mm
Can be
off-set to
suit

340mm 340mm 340mm


min. min. min.
600mm 600mm 600mm
max. max. max.

SAH - UO SAH - UT SAH - UC Ancon SAH - Sliding Anchors


15mm
50mm 160mm Ancon SAH Sliding Anchors have stems
95mm 160mm
15mm 15mm which fit within the cavity and accept ties
130mm 130mm that slide to accommodate vertical movement.
160mm
Available with six different head options as
standard, they can be supplied with one-way
or two-way ties with safety ends.
340mm
min. The standard fixing hole is 12mm diameter to
600mm
340mm 340mm suit Ancon M10 Single Expansion Bolts or
max.
min. min. M10 T Head Bolts to fit Ancon 28/15 Channel.
600mm 600mm
max. max. Ancon SAH Sliding Anchors have 25 x 5mm
stems and a maximum service capacity of 1kN
per stem when the upper tie is within 75mm of
the fixing. Ties should be spaced at a
minimum of 150mm and at least two ties
should be used per stem.
These drawings are examples only. All sliding
anchors are manufactured to suit individual
Head dimensions and hole positions are variable.
requirements.

Standard Lengths
200, 230mm
Slot is positioned
at the centre 75mm
SIS max.
of the tie
75mm
SPI max.
20mm to centre
of slot
Standard Lengths
135, 150mm
Other lengths and
slot positions available Other lengths available
to suit application to suit application
SAH - UF SAH - UO with
Extended Head

23
Wall Ties and Restraint Fixings

WALL STARTER SYSTEMS


36/8 Wall Extension System
The 36/8 Wall Extension System can be supplied
with either SP36 ties or, where some longitudinal
movement must be accommodated at the
joint, PP36 ties complete with debonding
sleeves. The channel can be supplied in
lengths of up to 3.4 metres with each length
having a series of holes to allow fixing to the
existing wall. The system is available as a kit
comprising a length of 36/8 channel 2400mm
long, six ties and five plugs and screws.
Staifix Universal Wall Starter System 36/8 Wall Extension System, SP36 Tie
This system includes all necessary fixings to
join a single skin of masonry, 2400mm high,
to an existing wall. Each pack includes 2 fixing
strips, 5 plugs, 5 washers, 5 screws and
10 wall ties. Suitable for wall widths from 60mm
to 250mm and masonry up to 8 metres in
height, this system will resist a wind load of up
to 4.5kN over a height of 2400mm. Wall Ties
slide within the fixing strip to course with the
bed joints of any masonry unit. This Universal
Wall Starter System meets the technical
requirements of the NHBC.

36/8 Wall Extension System, PP36 Tie Staifix Universal Wall Starter System

Staifix Cavity Starter Tie Staifix Starter Tie Staifix Frame Tie
This tie simplifies the building of an inner leaf This tie is quick and simple to install. It is The Staifix Frame Tie is used to join timber
of blockwork within an existing structure. It is suitable for use in brickwork and blockwork of door and window frames directly to brickwork.
ideal for barn conversions. up to 3 storeys or 8 metres in height and It is designed for use on buildings of up to 15
Length Cavity Embedment meets the technical requirements of the NHBC. metres in height, and meets the technical
mm mm mm requirements of the NHBC. The ties are
180 50-70 65-85
screwed horizontally into the frame,
200 70-90 65-85
220 90-110 65-85
surrounded by mortar and built into the bed
230 100-120 65-85 joints of the new brickwork.

Supplied complete with an 8mm nylon wall


plug, the Starter Tie is fixed into the existing
wall at an angle of 30° to the horizontal and
New Inner Leaf Existing Outer Leaf bent into the bed joints of the new brickwork.
Ties should be fixed at 225mm vertical centres
and be central to each leaf of the new wall.

The vertical spacing of frame ties depends on


the application. Please contact Ancon or your
local Staifix stockist for more information.

24
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

RESTRAINTS FOR STONE CLADDING


Reference should be made to BS 8298: 1994
“Design and installation of natural stone
cladding”, when selecting ties for restraining
stone cladding. Restraints should be designed
to resist wind loads and any imposed loads
from, for example, window cleaning equipment.
Each stone will normally be restrained in four
places, two at the top and two at the bottom.
These are usually situated in the horizontal
joints. The restraints should be located in
pre-formed mortises or holes positioned in the
centre of the thickness of the stone panel, and
located at 1/4 points for half bonded stones
and 1/5 points for stack bonded stones.
Restraints should be kept at least 75mm from
any corner with the peripheral distances between
any two restraints not exceeding 1200mm (see
page 26).
The embedment of restraint dowels and lips
into the stone should be at least 20mm.
To achieve this lipped ties, (LPBs) have a
25mm downstand and dowelled ties (DPBs
and YPBs) have 60mm long dowels.

Buchanan Galleries, Glasgow

Ancon YDB Ties Fixed to Blockwork

25
Wall Ties and Restraint Fixings

Section of Ties
Minimum sections for restraints for various
thickness of stone are shown in the table
below. Restraints for large stones and for use
where cavities are in excess of 100mm may
require special attention. They may need a
much bigger section than 20 x 2.5mm; ties
formed from 20 x 3mm, 25 x 3mm, 30 x 3mm
and 30 x 4mm are frequently used for
restraining stone cladding.
Minimum Section of Restraints
Minimum Section
Stone Thickness of Restraint
30mm and below 3mm dia wire Ancon LD21 Ties Fixed into 21/18 Omega Channel, Restraining Top of Stone
40mm 5mm dia wire
50mm and above 20 x 2.5mm

Drip Position
If a drip is required (e.g. YDB) please specify YPB
the position, indicating from which end of the YDB
tie the measurement is taken.
Min length 120mm Min length 40mm
Dowels 6x60mm loose dowel 6x60mm loose dowel
Standard dowels are 6mm in diameter and
60mm long. These will be welded into the tail
end of ties referenced D__, and supplied loose
with ties referenced Y__ and the multi-holed YP21
M__. 8mm and 10mm diameter dowels are MP21
also available and will usually be supplied
where larger section ties are required. Min length 70mm Min length 40mm
6x60mm loose dowel 6x60mm loose dowel
Wire Ties
The traditional method of fixing thin marble,
particularly for internal linings and low rise
cladding is with wire ties and plaster or mortar
LP21
dabs. Wire ties are manufactured from 3mm
MPB
and 5mm diameter wire.
Min length 70mm Min length 35mm
6x60mm loose dowel

WTA

LPB

MDS Min length 40mm

WTB Min length 140mm


6x60mm loose dowel ZDS

Min length 110mm

DP21
WTC
WTD
DDS
Min length 40mm
6x60mm welded dowel
Min length 120mm
6x60mm welded dowel

DPB

Min length 40mm LPL


6x60mm welded dowel
Min length 75mm

26
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

W
T
W/5 Stack bonded stone
W/4 Half bonded stone
t
1200mm max.

20mm

T/2

t
75mm 20mm
T/2

20mm
1200mm max.

Recommended Restraint Positions in Stone Cladding

Minimum Stone Thickness ‘T’ and Minimum Dimension Behind Restraint ‘t’
More than 3.7m above Soffits - including Sills, copings and
ground - including facias inlined soffits supported reveals
Type of Stone T (mm) t (mm) T (mm) t (mm) T (mm) t (mm)
Granite, slate, white
40 15 40 15 30 12
marble, quartzites
Hard limestone,
40 15 40 15 30 12
travertines
Limestone,
75 30* 75 30* 50 20*
sandstone
* t = T/2 if stone thickness (T) is greater than 75mm

Two Ancon YPB Ties Restraining Coping Stone

27
Wall Ties and Restraint Fixings

Ancon 150
The Ancon 150 is a grout-in masonry tie for
the restraint of 20 to 30mm thin facings, and
suitable for cavities up to 60mm wide. The 12
x 2mm corrugated body provides optimum
bond in a 12 x 90mm hole. The 50 x 3mm
dowel is supplied loose.

Ancon 150

Ancon Push-Off Bolt


The Push-Off Bolt provides the centre of stone
panels with additional resistance to the effects Museum of Scotland, Edinburgh
of impact loads, blast loads and positive wind
pressure. The Bolt features a mechanical
expander at one end which fixes securely into
the inner leaf. The external stone panel is
positioned with its inner face flush to the bolt’s
neoprene pad, which cushions the surface and
prevents any rattling. The Push-Off Bolt is
supplied in a variety of lengths to suit cavities
from 100 to 200mm.

Stone Insulation Inner Leaf

Ancon Push-Off Bolt

Ancon 2000 Thin Facing Restraints


Push-Off Bolt Facing Cavity Safe Working
Thickness Min. Max. Hole Size Load*
Reference (mm) (mm) (mm) (mm) (N)
20 25 70 8 x 90 600
2000/A
25 22 67 8 x 90 600
Ancon 2000 30 30 75 8 x 90 600
2000/B
Ancon 2000 restraint fixings are a simple and 40 25 70 8 x 90 600
secure method of fixing thin facing slabs. The 20 60 105 8 x 90 600
25 57 102 8 x 90 600
fixing is quickly and easily installed with the 2000 - 75
30 55 100 8 x 90 600
small diameter hole giving lower drilling costs 40 50 95 8 x 90 600
and minimum disturbance to the structure.
Other sizes available to order. *In grade 30N/mm2 concrete
Vertical and lateral adjustment is provided by
the slotted holes in the fixing clip.

Ancon 2000

Facing
thickness Cavity

28 Ancon 2000
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

REMEDIAL WALL TIES Installation of Remedial Wall Ties


Ancon 63 Setting Tools
Mechanical ties are easily installed by means
Corrosion of Cavity Wall Ties
of two Setting Tools. The tie is fitted to the Setting Tool - Outer
Wall ties are an essential element in the
setting tool for the inner leaf and inserted into
stability of masonry panels. Prior to 1978, wall
a pre-drilled hole in the wall. The required drill
ties were usually manufactured from galvanised
depth for each tie is shown in the table below.
mild steel. These ties were expected to last the
The inner shell is expanded by turning the
lifetime of the building, but for many years it
handle. The tool for the outer leaf, with a
has been recognised that some of these wall
hexagonal-shaped end, is then fitted and
ties have corroded after only 15 or 20 years.
adjusted to expand the outer shell. Both tools
When these ties corrode, they can expand should be turned until hand tight. Setting Tool - Inner
to seven times their original thickness.
To install Staifix Resin/Resin and TeploTie
This causes the brickwork to crack at the
(Type 2) remedial wall ties an extension nozzle
mortar joints and can result in major damage
and tube is required to pump resin across the
and sometimes the collapse of walls.
cavity and into the inner leaf. The extension
It is crucial that the problem is identified as tube is supplied in a standard length of
quickly as possible and the correct remedial 1000mm and is cut to suit on site.
action undertaken.
Spacing
No Standard (British or European) has yet
Ancon 63 Range
been defined for the spacing of remedial wall Cavity Widths Tie Lengths Drill Diameter Drill Depths
ties. However, accepted practice is to follow (mm) (mm) (mm) (mm)
PD 6697: 2010 that is 900mm horizontally and 50-75 200 10 60 min.
450mm vertically in a staggered pattern with 76-100 225 10 60 min.
101-125 250 10 60 min.
300mm vertical centres around openings within
126-175 300 10 60 min.
225mm of the opening. Note: For cavities over 100mm horizontal spacing may need to be reduced to 450mm.
Test Results Failure Loads (Pull-Out) for the Ancon 63 Range
The '63 range, Staifix R/R and Teplo2 have Compressive Failure
been tested independently in a variety of Strength Load
Base Material (N/mm2) (kN)
materials, a summary of results is given in the
Hard Brick (Accrington Nori) 80 5.6
tables. The failure loads noted are obtained Soft Brick (Yellow Imperial) 30 3.8
from standard tests in brick couplets and Portland Stone 20 5.3
provide indicative values of tie performance. Dense Aggregate Block 7 1.9
The couplet test produces results of a Note: Test results are a mean of 5 tests
conservative nature compared to actual wall Failure Loads (Pull-Out) for Staifix R/R
tests. Due to the variability of materials, it is Compressive Failure
often prudent to undertake a pull-out test on Strength Load
Base Material (N/mm2) (kN)
site, to verify the selection of an appropriate tie.
Dense Concrete Block 7.0 - 10.5 5.78
Fischer FIS P 380 C Resin Lightweight Concrete Block 2.8 - 3.5 2.87
This styrene-free injection resin supplied by Mortar Bed Joint, 1:1:6 Type (iii) PD 6697 - 5.37
Ancon is quick setting and suitable for a wide
range of applications. The two components Ancon Teplo2 Range
are safely mixed together inside the nozzle. Cavity Widths Tie Lengths Drill Diameter Tie Diameter
(mm) (mm) (mm) (mm)
Automatic mixing ensures an accurate
126-200 275, 300, 325 8 6
blending of the components and, being mixed
201-300 350, 375, 400, 425 10 7
only as required, the minimum of wastage.
Note: For applications outside those shown above, please contact Ancon.
Resin guns and additional mixing nozzles are
available. Failure Loads (Pull-Out) for the Ancon Teplo2 Range
Base Material Drill Depths 6mm Tie 7mm Tie
(mm) Failure Load (kN) Failure Load (kN)
Hard Brick (Accrington Nori) 50-65 8.98 10.03
Soft Brick (Yellow Imperial) 60-65 5.98 8.70
Portland Stone 50-65 6.33 7.21
Lightweight Concrete Block 70 min. 1.35 1.81
Dense Concrete Block 50-65 1.62 1.62

Note: The failure loads given are pull-out tests only. The overall performance of the tie may be limited by other factors
such as tie type. For further information please contact Ancon’s Technical Department to confirm suitability for specific
applications.

29
Wall Ties and Restraint Fixings
Ancon 63 Mechanical/Mechanical
Ancon MM 63
Used when tying together two leaves of solid 200mm for 50-75mm cavities
materials, this tie has mechanical expanders at 225mm for 76-100mm cavities
250mm for 101-125mm cavities
each end. Requires 10mm Ø holes. 300mm for 126-175mm cavities
Ancon 63 Resin/Mechanical
For use when the material in the inner leaf is
perforated, of low-density or a friable material. A
resin fixing may be used to eliminate any imposed
stress. Requires 10mm Ø holes. Ancon RM 63
Staifix Resin/Resin 200mm for 50-75mm cavities
225mm for 76-100mm cavities
Used where mechanical expanders are 250mm for 101-125mm cavities
unusable. Normally inserted into a 10mm Ø 300mm for 126-175mm cavities

hole, but if test facilities are required, a 12mm Ø


hole must be used. A plastic sieve can be used
to retain resin and is particularly useful in
perforated brick or hollow blockwork. A 12mm
Ø hole is required to fit the sieve. Staifix R/R
180mm for 40-60mm cavities
Stairib Bar 200mm for 61-80mm cavities
Stainless steel ribbed bar, resin-grouted into the 220mm for 81-100mm cavities

inner and outer leaves. Requires 10mm Ø hole


(6mm dia. bar) or 12mm Ø hole (8mm dia. bar).
Ancon AC 31
Used where bricks are removed then replaced
in the outer leaf. The wavy end is resin-bonded Stairib Bar
Length to order
into the inner leaf in a 10mm Ø hole. The 6, 8mm dia.
triangular end sits in the bed joint. Ancon AC 31
can be supplied with a drip or a neoprene ring.
Ancon AC 31C
Ancon AC 31
Similar to the AC 31 but cranked by 25mm to aid Lengths 175, 200 ,
fixing to the inner leaf. Requires 10mm Ø holes. 225 mm

Cameron T 47
Used for the repair of mass brickwork with an
unbonded brick façade, sometimes built from
snapped headers. The T end is built into the bed Ancon AC 31C
Lengths 175, 200,
joint and perpend, and hidden when the 225mm
brickwork is repointed. Requires 12mm Ø holes.
TeploTie (Type 2)
Basalt fibre wall tie that can be resin-fixed in
remedial and retrofit applications. This tie has a
thermal conductivity of only 0.7 W/mk. Requires
8mm Ø hole (6mm dia. bar) or 10mm Ø hole
Cameron T 47
(7mm dia. bar). Lengths 200, 250,
300mm 4.7mm dia.
HRT4/R
Used for tying the two leaves of a cavity wall or
separating wall where the first leaf has already
been built. The wavy end is resin-bonded into
TeploTie
the existing wall in a 10mm Ø hole. The tie is Lengths 275, 300, 325,
based on the Staifix HRT4 and has similar 375, 400, 425mm

properties.
Type A R/R
This is designed as a remedial tie for a
HRT4/R
separating wall. It will normally be inserted in Lengths 200, 225,
10mm Ø holes and resin-bonded into both 250mm

leaves. It meets the requirements of a Type A


wall tie to Approved Document E.

Type A R/R
Length 225mm

30
Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

STAIFIX-THOR HELICAL CRACK OTHER ANCON PRODUCTS


STITCHING KIT Masonry Support Systems
The Staifix-Thor Helical Crack Stitching Kit is a Masonry cladding on concrete or steel frames
high strength, non-disruptive solution for the is normally supported from stainless steel
permanent repair of cracked masonry. It is support systems. AnconOptima and Ancon
available from builders merchants and MDC Systems create a continuous angle to
specialist distributors. support the outer leaf of masonry. Ancon
Ideal for either the remedial specialist or the Individual Brackets support masonry features
contractor with a one-off repair job, the kit such as curves and arches. A full design
contains Staifix-Thor Helical reinforcing bars service is available to specifiers and users of
(10 x 1000mm), masonry repair grout (3 litres), Ancon systems.
a paddle for grout mixing, a grout applicator
Masonry Reinforcement
gun with a flat nozzle, and a finger trowel.
Ancon AMR masonry reinforcement improves
the structural performance of a wall by
providing additional resistance to lateral loads.
Located in the bed joint, it has a flattened
profile to maintain good mortar cover even
when lapped or used with wall ties. It is
available in various standard configurations
to suit a range of loading conditions and
wall widths.

Windposts and Parapet Posts


Purchase of the Ancon kit, in preference to Large panels of masonry or panels with
obtaining all the components individually, openings can often be difficult to justify
guarantees the correct specification and structurally. Ancon Windposts are designed to
compatibility of reinforcement, grout and tools provide additional lateral support for panels of
for this specific application. The kit is supplied brickwork. The range is manufactured from
in a single box with full installation instructions. stainless steel and includes Windposts which
can be installed into the inner leaf of blockwork
and Windposts for installation into the cavity,
which leave the blockwork undisturbed.
Parapet Posts are used as vertical support for
brickwork in either parapet or spandrel panels.

Insulated Balcony Connections


Ancon Isolan connectors join external concrete
balconies to internal concrete floor slabs.
Used to minimise cold bridging, they provide
The stainless steel helical bars are chemically
continuity to the thermal insulation. Standard
bonded into bed joints to stitch cracks,
systems, comprising rigid CFC-free
redistributing tensile forces and stabilising the
polystyrene insulation and duplex stainless
structure. On completion, the bar and grout
steel shear reinforcement, suit most depths of
are concealed, retaining the original character
cantilevered and simply supported balconies.
of the wall.
Conventional reinforcing bars are used to
500mm 500mm provide the tension and compression
reinforcement.

Tension Systems
Tie bars are increasingly being used in
structures and buildings as an architectural as
well as a structural element. Ancon 500
Tension Systems comprise a range of
components which can be supplied in carbon
500mm 500mm steel or stainless steel in a variety of sizes and
Please note it is essential that the cause of the finishes. They have a high load capacity and
cracking is established and eliminated prior to look particularly impressive when used with
the installation of this system. large areas of glazing or curved timber trusses.

31
Ancon Building Products Ancon (Schweiz) AG
President Way, President Park Gewerbezone Widalmi 10
Sheffield S4 7UR 3216 Ried bei Kerzers
United Kingdom Switzerland
Tel: +44 (0) 114 275 5224 Tel: +41 (0) 31 750 3030
Fax: +44 (0) 114 276 8543 Fax: +41 (0) 31 750 3033
Email: info@ancon.co.uk Email: info@ancon.ch
Visit: www.ancon.co.uk Visit: www.ancon.ch

Ancon (Middle East) FZE Ancon Building Products GesmbH


PO Box 17225 Gerspergasse 9/3 Top 1
Jebel Ali A-1210 Vienna
Dubai Austria
United Arab Emirates Tel: +43 (0) 1 259 58 62-0
Tel: +971 (0) 4 883 4346 Fax: +43 (0) 1 259 58 62-40
Fax: +971 (0) 4 883 4347 Email: info@ancon.at
Email: info@ancon.ae Visit: www.ancon.at
Visit: www.ancon.ae
Ancon GmbH
Ancon Building Products Bartholomäusstrasse 26
114 Kurrajong Avenue 90489 Nuremberg
Mount Druitt Germany
Sydney Tel: +49 (0) 911 955 1234 0
NSW 2770 Fax: +49 (0) 911 955 1234 9
Australia Email: info@anconbp.de
Tel: +61 (0) 2 8808 1111 Visit: www.anconbp.de
Fax: +61 (0) 2 9675 3390
Email: info@ancon.com.au
Visit: www.ancon.com.au

These products are available from:

The construction applications and details provided in this literature are indicative only. In every case, project
working details should be entrusted to appropriately qualified and experienced persons.

Whilst every care has been exercised in the preparation of this document to ensure that any advice,
recommendations or information is accurate, no liability or responsibility of any kind is accepted in respect of
Ancon Building Products.

With a policy of continuous product development Ancon Building Products reserves the right to modify product
design and specification without due notice.
© Ancon Building Products 2011

ISO 9001: 2008 ISO 14001: 2004 OHSAS 18001: 2007


FM 12226 EMS 505377 OHS 548992

You might also like