Date : 5 /9 /2017 SCOPE OF SUPPLY SQB001887_1

Affaire/Quote Name : 17IDN019

Customer : PT. MEKATRONIC ARTHA NUSANTARA

The vessel will be equipped with :

- 2 auxiliary generator(s)

according to the following specification :

- Marine Genset : 125KVA @ 50Hz - 380 V 6W105S - EXC - PRP - IMO II Monitoring and control
system : MAXI
SCOPE OF SUPPLY

1. MAIN TECHNICAL DATA

AUXILIARY GENERATOR 100 KWe - 125 KVA at pf 0,8 - 50Hz

1. ENGINE TECHNICAL DATA

MOTEUR BAUDOUIN:6W105S
107 kWm at 1500 rpm
PRP rating: Prime power unlimited time. Average load factor 70%. 100% power 500 hr/year max.
Overload 10% 1hr/12hr

Bore / Stroke 105*130 mm


Swept volume 6.75 litres
Cylinder configuration 6 in line
Rotation CCW
Flywheel 11.5"
Flywheel housing SAE 3

Running conditions
Ambient temperature 45°C
Raw water temperature 32°C
Other conditions according to ISO3046

Certification / Homologation
Emissions : IMO2(individual EIAPP certificate not included)
ENGINE SPECIFICATION
a. COOLING SYSTEM

Double cooling circuits high and low temperature


Heat exchanger engine mounted
Self priming raw water pump (engine driven)
Fresh water connection for emergency circuit (emergency pump not included)
Flexible interfaces on engine water circuits
Engine driven fresh water pump

b. FUEL OIL CIRCUIT

Mechanical fuel oil injection


Monoblock injection pump
Fuel feed pump and manual fuel priming pump
Double wall injection pipes bundle
Duplex screwable fuel filters
Fuel oil leakage collecting box
Water separator
Connecting flexible hoses
c. LUBE OIL CIRCUIT

Engine mounted lube oil cooler


Manual draining pump
Engine driven lube oil pump

d. INTAKE AIR AND EXHAUST GAS CIRCUITS

Heat insulated turbocharger(s)


Low temperature intake air cooler(s)
Dry air filter(s)
Heat insulated exhaust gas manifold(s)
Exhaust gas expansion bellow after engine with counter flanges
Exhaust gas silencer, sound attenuation 23 dBA - DN100 Axial
e. START – STOP – SPEED CONTROL SYSTEMS

24VDC electrical starter


0 A battery charger
f. ALTERNATOR

Brand Leroy Somer


Type LSAM44.3 M8
Power 100 KWe - 125 KVA
Tension 380 Vac
Frequency 50Hz
Heating class: H
Voltage regulation: AREP
Ingress protection: IP23
Single bearing
Space heater
CT for parallel running
g. CONTROL SYSTEM

MAXI control and monitoring system according to specification:

Generator baseframe mounted cabinet


- Alarm and parameters monochrome display unit
- Engine start /stop
- Local/off/remote switch
- Emergency stop
- Buzzer
- Light test
- 3 metres of engine wiring for remote installation
- Monitoring & Control
- Tachometer - Service meter
- Hourmeter
- Lube oil pressure indication
- Lube oil pressure low (alarm)
- Lube oil pressure very low (shutdown)
- Fresh water temperature indication
- Fresh water temperature high (alarm)
- Fresh water temperature very high (shutdown)
- Fresh water low level (alarm)
- Injection pipe fuel leakage (alarm)
- Overspeed (shutdown)
- Exhaust gas temperature indication
- High exhaust gas temperature (alarm)
Remote Control Panel
- Alarm and parameters monochrome display unit
- Engine start/stop
- Emergency stop
- Buzzer
- 40 wiring to engine room

H. SPARE PARTS
One set of spare parts for first maintenance interval

I. DOCUMENTATION
- Standard documentation (soft copy) including:
- 1 operation manual
- 1 spare parts manual
- 1 set of technical installation and operation recommendations

Documentation hard copies :


- 1 operation manual(s)
- 1 spare parts catalogue(s)catalogue pièces de rechange

J. TESTING - PAINTING
Engine factory test with power adjustment
Special marine painting color "Blue Moteurs Baudouin"
K. PACKING - PROTECTION
Sea worthy packing
M.D.14.EN.08.17

6 W105S
Marine Diesel Generators
4 strokes diesel engine, direct injection
Power definition
Standard ISO 3046/1 - 1995 (F)

Reference conditions
Ambiant tempeature 25 °C / 77 ° F
Barometric pressure 100 kPa
Relative humidity 30 %
Raw water temperature 25 °C / 77 ° F

Fuel oil
Relative density 0,840 ± 0,005
Lower calorific power 42 700 kJ/kg
Consumption tolerances ±5%
Air inlet limit de temperature 35 °C / 95 °F

Emissions IMO Tier II


Not contractual picture

6 W105S
Injection Speed control Cylinder configuration Bore/stroke (mm) Displacement (l)
Mechanical Electronic 6 in line 105*130 6.75

3 PHASES SYNCHRONOUS GENERATOR


Frequency 50/60 Hz - 4 poles
Insulation / Heating class H/H
Voltage regulation Electronic
Excitation Brushless
Protection / Impregnation IP23 / Marine
Construction type Single bearing

RATING TABLE
PRP
Frequency rpm kWm kWe kVA Standard Voltage
50 Hz 1500 107 100 125 3*380
50 Hz 1500 129 120 150 3*380
60 Hz 1800 116 108 135 3*440
60 Hz 1800 144 136 170 3*440

Prime running power (PRP)

Variable load with mean power calculated on 250 running hours

No restriction on use if mean power ≤ 75% of nominal power

Total operating time at 100% nominal power shall not exceed 500 hours per year

10% overload available 1 hour each 12 hours


SPECIFIC FUEL CONSUMPTION

PRP 75% PRP 50% PRP


HZ kVA kWe kWm g/kWh l/h kWm g/kWh l/h kWm g/kWh l/h
50 125 100 107 199 25 81 203 19 53 258 16
50 150 120 129 194 29 97 201 23 75 228 20
60 135 108 116 203 28 87 207 21 58 243 16
60 170 136 144 200 34 109 202 26 73 218 18

OPTIONAL EQUIPMENTS (extract)

Mechanical Electrical
Keel cooling engine water circuits configuration Electrical prelube and drainage pump
Exhaust gas muffler Jacket water preheater
Communication port (canbus J1939)

Classification
Fully Unmanned Machinery Space (UMS)
Classification Societies approved package

DIMENSIONS AND DRY WEIGHT

Moteurs Baudouin reserve the right to modify these specifications without notice. Document not contractual.
C

A B

A B C Kg
125-135 KVA 1991 1015 1130 1403

150-170 KVA 2031 1015 1130 1438

*without water & oil

Société Internationale des Moteurs Baudouin


Technoparc du Brégadan - CS 50001 - 13711 Cassis Cedex - France - tel. +33 488 688 500 - fax +33 488 588 501 - www.baudouin.com