Steam plant, steam engine, boiler, condenser, Rankine cycle
OVERVIEW:
1. INTRODUCTION
The steam plant helps the students understand some principles of thermodynamics using a
laboratory scale steam plant. The steam plant consists of several components: a boiler, a
steam engine, a condenser and a feed pump. In large power plants, steam turbines are used
but for a small- scale laboratory set up, a steam engine is used.
Heat is supplied to the boiler via two immersion heaters (3 kW each). The water in the boiler
must be clean and free from minerals. The water is pumped to the boiler from a reservoir.
The boiler raises saturated steam to a maximum of 4 bars.
The steam engine is a totally enclosed, two cylinders, single acting trunk piston with nominal
output of 120 W at 2000 rev per min. The steam is expanded in the steam engine to produce
useful work.
The condenser condenses the exhaust steam in Saturated Steam from the steam engine into
water. The water is then returned to the reservoir and pump back into the boiler and the
cycle continues.
THEORY
For the energy balance, consider the complete system of boiler, steam engine,
condenser surrounded by the control surface shown by the dotted line. The steady
flow energy balance is given by
b = ms (h1-hw)
Q1
R = W1
ms(hw - h1)
Steam quality
x= h[enthalpy after throttling calorimeter] – hf[@boiler pressure]
hfg[@ boiler pressure]
Power W = 2R(F1-F2)N/60
R= Brake radius (0.056 m)
F = spring load(N)
N= engine speed ( rev. min-1)
2. Operation
1. Connect the cooling water supply to the inlet pipe of the condenser and connect
the outlet pipe to a suitable drain. Connect the outlet from the condensate
collector to a suitable drain or container.
3. Check that the filter on the end of the boiler pump suction pipe is in place and
clean. Place the end of the pipe into the reservoir tank supplied. Fill the tank with
clean soft water to at least half way. Make sure the reservoir is kept at least half
full to ensure no air is drawn in to the pump.
5. Switch on the temperature display, making sure that the displays work, they will
self test with the words: 'TQ' and TE5'.
6. Make sure that the red emergency stop button is pulled out. Switch on the mains
supply and then the boiler feed pump.
7. Open the pump bleed valve, and check that the pump is operating. When there is
a steady flow of water, with no air bubbles, close the bleed valve and begin to fill
the boiler to the upper mark on the sight gauge. The boiler should fill in 8 to 10
minutes. When the boiler is full, close the boiler steam valve.
8. Slacken the band brake to ensure that the engine is not loaded. Zero the spring
balances.
9. Switch on both heaters, the indicator lamps will light up to show the heaters are
working. The boiler pressure will rise as indicated on the boiler pressure gauge.
Make sure that the calorimeter valve is fully closed.
2.2 Start Up
1. When the boiler pressure has reached approximately 60 kN/m2 (0.6 bar), open
the boiler steam valve until the engine inlet pressure reaches 40 kN/m2 to 50
kN/m2 (0.4 bar to 0.5 bar).
Note : The pressure in the boiler may be higher than 60 kN/m2 before
steam is produced. Check the boiler temperature, if it is higher than 100 °C,
then it is likely that steam is available.
2. In one swift movement, pull upwards on the starting knob and let go. The engine
should start to turn.
d) Check that the steam engine is not seized - watch the pulley at the
front of the engine and see if it turns as you pull the starting knob
upwards.
4. To keep the boiler pressure up to a sufficient level, switch the heaters on when
necessary. The boiler safety valve will begin to operate at approximately 340
kN/m2 (3.4 bar) but will not be fully open until 400kN/m 2. The safety valve may
vent a little steam constantly at a higher boiler pressure.
5. Before taking a set of readings, run the apparatus for at least 10 minutes for
conditions to stabilize. Regularly check the level of the water in the boiler. Switch
on the feed pump when necessary to make sure that the level lies between the
permitted limits.
Note:
Take results when the feed pump is not in operation, the apparatus will run
at full power for about 25 minutes while the water level falls from maximum
to minimum. When the pump is operating steam pressure and power output
falls.
3. EXPERIMENTS
3.1 Procedure
Run the engine at a constant speed 2000 rev per min-1 at varying engine load.
To do this:
a. Load the right hand spring balance in 2 N stages to 20 N.
b. Vary the boiler pressure valve to achieve a constant speed (
100 rev.min-1)
Record the parameters in the data sheet
(Measure the condensate flow rate by measuring the volume collected in a measuring
cylinder for a period of 1 minute)
Analyze the results
After use:
a. Disconnect the electrical and water supplies
b. Allow the boiler to cool down and open the boiler drain valve.
c. Drain any water from the apparatus
d. Switch off the temperature display
4. TUTORIALS