Professional Documents
Culture Documents
Issue 01
Date 2016-03-07
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
2 Overview......................................................................................................................................... 6
2.1 Definition........................................................................................................................................................................7
2.2 Benefits........................................................................................................................................................................... 7
2.3 Architecture.................................................................................................................................................................... 7
5 Related Features...........................................................................................................................64
5.1 Features Related to TDLBFD-00201801 Coverage Based Intra-frequency Handover................................................64
5.2 Features Related to TDLBFD-00201802 Coverage Based Inter-frequency Handover................................................64
5.3 Features Related to TDLBFD-00201805 Service Based Inter-frequency Handover................................................... 65
5.4 Features Related to TDLBFD-00201804 Distance Based Inter-Frequency Handover................................................ 66
5.5 Features Related to TDLOFD-001050 Mobility between TDD-LTE and FDD-LTE.................................................. 67
6 Network Impact........................................................................................................................... 68
6.1 TDLBFD-00201801 Coverage Based Intra-frequency Handover................................................................................69
6.2 TDLBFD-00201802 Coverage Based Inter-frequency Handover................................................................................69
6.3 TDLBFD-00201805 Service Based Inter-frequency Handover................................................................................... 69
6.4 TDLBFD-00201804 Distance Based Inter-Frequency Handover................................................................................ 70
6.5 TDLOFD-001050 Mobility between TDD-LTE and FDD-LTE.................................................................................. 70
7 Engineering Guidelines............................................................................................................. 71
7.1 TDLBFD-00201801 Coverage Based Intra-frequency Handover................................................................................72
7.1.1 When to Use Coverage-based Intra-Frequency Handover........................................................................................ 72
7.1.2 Required Information................................................................................................................................................ 72
7.1.3 Requirements............................................................................................................................................................. 72
7.1.4 Data Preparation and Feature Activation...................................................................................................................72
7.1.4.1 Data Preparation..................................................................................................................................................... 72
7.1.4.2 Activation............................................................................................................................................................... 79
7.1.5 Activation Observation..............................................................................................................................................80
7.1.6 Deactivation...............................................................................................................................................................80
7.1.7 Performance Monitoring............................................................................................................................................81
7.1.8 Parameter Optimization............................................................................................................................................. 82
7.1.9 Troubleshooting......................................................................................................................................................... 85
7.2 TDLBFD-00201802 Coverage Based Inter-frequency Handover................................................................................86
7.2.1 When to Use Coverage-based Inter-Frequency Handover........................................................................................ 86
7.2.2 Required Information................................................................................................................................................ 86
7.2.3 Requirements............................................................................................................................................................. 86
7.2.4 Data Preparation and Feature Activation...................................................................................................................87
7.2.4.1 Data Preparation..................................................................................................................................................... 87
7.2.4.2 Activation............................................................................................................................................................... 97
7.2.5 Activation Observation..............................................................................................................................................98
7.2.6 Deactivation...............................................................................................................................................................98
7.2.7 Performance Monitoring............................................................................................................................................99
7.2.8 Parameter Optimization........................................................................................................................................... 100
7.2.9 Troubleshooting....................................................................................................................................................... 109
7.3 TDLBFD-00201805 Service Based Inter-frequency Handover................................................................................. 109
7.3.1 When to Use Service Based Inter-frequency Handover.......................................................................................... 109
7.3.2 Required Information.............................................................................................................................................. 109
7.3.3 Requirements........................................................................................................................................................... 110
7.3.4 Data Preparation and Feature Activation.................................................................................................................110
7.3.4.1 Data Preparation................................................................................................................................................... 110
7.3.4.2 Activation..............................................................................................................................................................114
7.3.5 Activation Observation............................................................................................................................................ 115
7.3.6 Deactivation............................................................................................................................................................. 116
7.3.7 Performance Monitoring..........................................................................................................................................116
7.3.8 Parameter Optimization........................................................................................................................................... 117
7.3.9 Troubleshooting....................................................................................................................................................... 119
7.4 TDLBFD-00201804 Distance Based Inter-Frequency Handover.............................................................................. 120
7.4.1 When to Use Distance-based Inter-Frequency Handover....................................................................................... 120
7.4.2 Required Information.............................................................................................................................................. 120
7.4.3 Requirements........................................................................................................................................................... 120
7.4.4 Data Preparation and Feature Activation.................................................................................................................121
7.4.4.1 Data Preparation................................................................................................................................................... 121
7.4.4.2 Activation............................................................................................................................................................. 122
7.4.5 Activation Observation............................................................................................................................................123
7.4.6 Deactivation.............................................................................................................................................................123
7.4.7 Performance Monitoring..........................................................................................................................................124
7.4.8 Parameter Optimization........................................................................................................................................... 124
7.4.9 Troubleshooting....................................................................................................................................................... 127
7.5 UL-Quality-based Inter-Frequency Handover............................................................................................................128
7.5.1 When to Use UL-quality-based Inter-Frequency Handover....................................................................................128
7.5.2 Required Information.............................................................................................................................................. 128
7.5.3 Requirements........................................................................................................................................................... 128
7.5.4 Data Preparation and Feature Activation.................................................................................................................128
8 Parameters................................................................................................................................... 154
9 Counters...................................................................................................................................... 275
10 Glossary..................................................................................................................................... 518
11 Reference Documents............................................................................................................. 519
1.1 Scope
This document describes intra-RAT mobility management in connected mode within E-
UTRAN, including its technical principles, related features, network impact, and engineering
guidelines.
Any managed objects (MOs), parameters, alarms, or counters described herein correspond to
the software release delivered with this document. Any future updates will be described in the
product documentation delivered with future software releases.
This document applies only to LTE TDD. Any "LTE" in this document refers to LTE TDD,
and "eNodeB" refers to LTE TDD eNodeB.
Micro BTS3205E
2 Overview
Based on the frequency of the target cell, intra-RAT mobility management can be classified
into intra-frequency mobility management and inter-frequency mobility management.
2.1 Definition
Intra-Frequency Mobility Management
Intra-frequency mobility management is implemented by handovers between E-UTRAN cells
using the same frequency. A network may use the same frequency in different cells, and
therefore the eNodeB needs to support intra-frequency handovers within the network.
2.2 Benefits
Intra-RAT mobility management in connected mode provides the following benefits:
l Ensures the continuity of radio network coverage and provides uninterrupted
communication services for UEs.
l Provides means to transfer UEs and supports flexible networking to meet operators'
service steering and load balancing requirements.
2.3 Architecture
For the network architecture for intra-RAT mobility management in connected mode, see
Overview of Mobility Management in Connected Mode.
Event A3
Event A3 indicates that the signal quality in a neighboring cell is better than that in the
serving cell. When coverage-based intra-frequency handover is enabled, the eNodeB sends
measurement configurations related to event A3 to the UE during UE radio bearer setup.
The entering and leaving conditions of event A3 are shown in Figure 3-1 and Figure 3-2,
respectively. For details about event A3, see section 5.5.4.4 "Event A3 (Neighbour becomes
offset better than PCell)" in 3GPP TS 36.331 V10.1.0.
l Entering condition: Mn + Ofn + Ocn - Hys > Ms + Ofs + Ocs + Off
After receiving an event A3 from a UE, the eNodeB makes handover decision based on
the reported candidate cell list.
l Leaving condition: Mn + Ofn + Ocn + Hys < Ms + Ofs + Ocs + Off
If the leaving condition of event A3 is met, the UE no longer reports event A3.
Assume that both Hys and Off are set to 2 dB. The eNodeB detects that the signal quality in
the source cell always drops rapidly and the signal quality in the target cell always rises
quickly in a handover.
To facilitate intra-frequency handovers, you can set Ocs to -1 dB for the serving cell and set
Ocn to 1 dB for the target cell.
Ofs and Ofn use the same value for an intra-frequency handover. Assume that they are set to 0
dB, then the entering condition of event A3 is as follows: Mn + 0 + 1 - 2 > Ms + 0 - 1 + 2.
That is, event A3 can be triggered when the signal quality of the target cell is 2 dB higher than
that of the serving cell.
Mn Mn is the -
measurement
result of the
neighboring cell.
EUTRAN HoMeasComm.EutranFilt
RSRQ filter erCoeffRSRQ
coefficient
Table 4-1 Events for triggering/stopping measurements and handover during a coverage-
based inter-frequency handover
Procedure Subproced Triggering Events Stopping Events
ure
NOTE
l With preferential blind handover, the eNodeB preferentially performs coverage-based inter-
frequency handovers in a blind manner. That is, the eNodeB does not have to deliver events that
trigger inter-frequency handover. The IfCoverPreBlindHoSwitch option of the
CellHoParaCfg.CellHoAlgoSwitch parameter specifies whether to enable preferential blind
handover.
l After a UE accesses the network, the eNodeB checks whether there are suitable blind neighboring
cells or frequencies and delivers event A2 for blind handover. After the event A2 is triggered, the
eNodeB transfers the UE out of the serving cell through blind redirection to avoid service drop. The
process is called emergent blind handover. The EmcInterFreqBlindHoSwitch option of the
CellHoParaCfg.CellHoAlgoSwitch parameter specifies whether inter-frequency or inter-RAT
redirection is used during emergent inter-frequency blind handover.
l In either of the following scenarios, the eNodeB delivers measurement configuration for
only blind event A2:
– The InterFreqHoA2OptSwitch option of the
ENodeBAlgoSwitch.HoSignalingOptSwitch parameter is selected, and the UE
does not support inter-frequency measurements.
– The configured event A2 threshold for inter-frequency measurements is less than or
equal to blind event A2.
l If no blind handover cell or frequency priority in connected mode is configured, the
eNodeB does not deliver blind event A2.
When the blind handover switch is turned on and the signal quality in the serving cell is lower
than the specified threshold, the UE reports event A2 for inter-frequency measurement. The
eNodeB directly performs inter-frequency blind handover.
l If the option is selected, the eNodeB sends measurement configuration for event A2
when the UE sets up an RRC connection, and sends measurement configuration for event
A1 after it receives an event A2 from the UE. This reduces the reporting of invalid event
A1. Figure 4-2 shows inter-frequency measurement based on event A4/A5. Figure 4-4
shows inter-frequency measurement based on event A3.
l If the option is deselected, the eNodeB sends measurement configuration for both event
A2 and event A1 when the UE sets up an RRC connection. Figure 4-3 shows inter-
frequency measurement based on event A4/A5. Figure 4-5 shows inter-frequency
measurement based on event A3.
It is recommended that the ReduceInvalidA1A2RptSigSwitch option and the
TrigQuanBothMeasOptSw option of the ENodeBAlgoSwitch.HoCommOptSwitch
parameter be selected on the live network. When
IntraRatHoComm.InterFreqHoA1A2TrigQuan is set to BOTH, as shown in Figure 4-2,
the inter-frequency measurement procedure is as follows:
During the triggering and stopping of measurements, RSRP- and RSRQ-based procedures are
mutually independent. This prevents premature event A1 delivering and invalid event A1
reporting. In addition, this prevents the delivering of invalid event A1 contents. When an
RSRP-triggered event A2 is received, RSRP-based measurement is triggered irrespective of
whether there is RSRQ-based measurement. When RSRP-triggered event A1 is received,
RSRP-based measurement is stopped.
Figure 4-2 Triggering and stopping of measurement when event A2 is delivered earlier than
event A1 (inter-frequency measurement based on event A4/A5)
Figure 4-3 Triggering and stopping of measurement when events A2 and A1 are delivered
simultaneously (inter-frequency measurement based on event A4/A5)
Figure 4-4 Triggering and stopping of measurement when event A2 is delivered earlier than
event A1 (inter-frequency measurement based on event A3)
Figure 4-5 Triggering and stopping of measurement when events A2 and A1 are delivered
simultaneously (inter-frequency measurement based on event A3)
4.1.1.1 Event A2
Event A2 indicates that the signal quality of the serving cell is lower than a threshold.
The variables in the preceding formulas are described in Table 4-2 and Table 4-3. Thresholds
related to event A2 vary according to events that are used to trigger inter-frequency
handovers.
Table 4-3 Thresholds related to event A2 according to events that are used to trigger inter-
frequency handovers
Events That Parameter Parameter ID of Parameter Description
Trigger Name of the the Threshold
Inter- Threshold
Frequency
Handover
TDD CnOperatorHoCf
g.TddIfHoA2Thd
RsrpOffset
(eNodeB level) or
CELLOPHOCF
G.TddIfHoA2Thd
RsrpOffset (cell
level)
The eNodeB delivers measurement configurations for event A2 for target-based measurement
as follows:
l If the FDD and TDD threshold offsets are set to different values, the eNodeB delivers
two measurement configurations for events A2, with one corresponding to an FDD
frequency and the other corresponding to a TDD frequency. After a UE reports an event
A2 related to a frequency, the eNodeB delivers the measurement configuration of the
related frequency.
l If the FDD and TDD threshold offsets are set to the same value, the eNodeB delivers one
measurement configuration for event A2, without distinguishing between the FDD and
TDD frequencies. After a UE reports an event A2, the eNodeB delivers two
measurement configurations, one for the FDD frequency and the other for the TDD
frequency.
Pay attention to the following points related to event A2 for target-based measurement:
l If only either of the offset is set to -100, the inter-frequency measurement of an FDD or
TDD frequency is not triggered.
l If both offset values are set to -100, the effect is the same as those set to 0. In this case,
the eNodeB sends an inter-frequency event A2, with the threshold set to the event A2
threshold value.
l If the calculated RSRP threshold is lower than the protocol-specified minimum value,
the protocol-specified minimum value is used as the RSRP threshold.
l If the calculated RSRP threshold is higher than the protocol-specified maximum value,
the protocol-specified maximum value is used as the RSRP threshold.
When eNodeB- and cell-level threshold offset parameters coexist, the cell-level
parameter is used as the actual value. It applies to the FDD and TDD co-site scenarios
where FDD cell policies differ from TDD cell policies.
4.1.1.2 Event A1
Event A1 indicates that the signal quality of the serving cell is higher than a threshold.
The entering and leaving conditions of event A1 are shown in Figure 4-7. For details about
event A1, see section 5.5.4.2 "Event A1 (Serving becomes better than threshold)" in 3GPP TS
36.331 V10.1.0.
l Entering condition: Ms - Hys > Thresh
When event A1 is triggered, the eNodeB receives an event A1 from the UE.
l Leaving condition: Ms + Hys < Thresh
When the leaving condition of event A1 is met, the eNodeB no longer reports event A1.
The variables in the formulas for event A1 are the same as those in the formulas for event A2.
Thresholds related to event A1 also vary according to events that are used to trigger inter-
frequency handovers, as described in Table 4-6.
Table 4-6 Thresholds related to event A1 according to events that are used to trigger inter-
frequency handovers
Events Parameter Parameter ID of Parameter Description
That Name of the the Threshold
Trigger Threshold
Inter-
Frequenc
y
Handover
A3 based InterFreqHoGrou
Interfreq A1 p.A3InterFreqHo
RSRQ A1ThdRsrq
threshold
Events A4 A4A5 Based InterFreqHoGrou This parameter is set for each QCI.
and A5 Interfreq A1 p.InterFreqHoA1
RSRP ThdRSRP
Threshold
Other parameters related to the event A1 report are the same as those related to event A2
report, as listed in Table 4-4.
You must set the thresholds related to event A1 to be higher than those related to event A2. If
the RSRP threshold offset for FDD or TDD frequencies are set, the thresholds related to event
A1 must be greater than or equal to the sum of the thresholds related to event A2 and the
offset.
EUTRAN HoMeasComm.Eutra
RSRQ filter nFilterCoeffRSRQ
coefficient
NOTE
In a directional handover, the eNodeB specifies frequencies for the UE. During directional handover
measurement, the eNodeB delivers only the highest-priority frequency to the UE.
l When directional handover is activated, the eNodeB selects and delivers the highest-
priority frequency to the UE. If the number of frequencies with the highest priority
exceeds the maximum, the eNodeB randomly selects frequencies from these frequencies.
– The EutranInterNFreq.VoipPriority parameter indicates the frequency priority of
UEs with voice bearers for directional handover.
– The EutranInterNFreq.PsPriority parameter indicates the frequency priority of
UEs without voice bearers for directional handover.
l When directional handover is not activated, the eNodeB delivers frequencies for
measurement based on the full specifications.
The FixedMeasObjIDSwitch option of the
CellAlgoSwitch.MultiFreqPriControlSwitch parameter specifies the frequency priority.
The eNodeB selects the frequencies for measurement in descending order of frequency
priority till the number of selected frequencies reaches the maximum. If a priority maps
multiple frequencies and the number of frequencies for measurement exceeds the
maximum when all these frequencies are selected, the eNodeB randomly selects
frequencies with this priority till the number of selected priorities reaches the maximum.
– When this option is deselected, the frequency priority is determined by the
EutranInterNFreq.ConnFreqPriority parameter. A larger value indicates a higher
priority. The eNodeB selects the frequencies for measurement in descending order
of frequency priority till the number of selected frequencies reaches the maximum.
– When this option is selected, the frequency priority is determined by the
EutranInterNFreq.MeasFreqPriority parameter. A larger value indicates a higher
priority. The eNodeB sets measurement object IDs based on frequency priorities to
control the UE's actual measurement priorities. This ensures that the UE
preferentially reports the measurement reports on high-priority frequencies.
For details about the maximum number of frequencies and the maximum number of
neighboring cells, see Overview of Mobility Management in Connected Mode.
NOTE
l When Thresh1 of event A5 is less than or equal to the threshold of blind event A2, the eNodeB does
not deliver measurement configuration for event A5.
l If carrier aggregation (CA) is enabled and the EutranInterNFreq.InterFreqHoEventType
parameter is set to EventA4(EventA4), the eNodeB will send a measurement configuration for
event A5 to trigger an inter-frequency measurement when a CA UE reports an event A2 in the
primary serving cell (PCell). For details, see Carrier Aggregation.
4.1.3.1 Event A3
Event A3 triggers inter-frequency handovers the same way as it triggers intra-frequency
handovers. For details, see 3.1 TDLBFD-00201801 Coverage Based Intra-frequency
Handover.
All parameters (other than Ofn and Off) for event A3 that triggers inter-frequency handovers
are the same as those for event A3 that triggers intra-frequency handovers. Table 4-8 lists the
parameters related to event A3.
Mn Mn is the -
measurement
result of the
neighboring cell.
4.1.3.2 Event A4
Event A4 indicates that the signal quality of a neighboring cell is higher than a threshold.
The entering and leaving conditions of event A4 are shown in Figure 4-8. For details about
event A4, see section 5.5.4.5 "Event A4 (Neighbour becomes better than threshold)" in 3GPP
TS 36.331 V10.1.0.
CoverageBased When the triggering The threshold parameter is set for each
Interfreq RSRP threshold is RSRP, the QCI.
threshold threshold value equals The threshold offset parameter is set
InterFreqHoGroup.InterF for each inter-frequency neighboring
reqHoA4ThdRSRP plus frequency.
EutranInterNFreq.IfHoTh
dRsrpOffset.
4.1.3.3 Event A5
Event A5 indicates that the signal quality of the serving cell is lower than threshold 1
(Thresh1) and the signal quality of a neighboring cell is higher than threshold 2 (Thresh 2).
The entering and leaving conditions of event A5 are shown in Figure 4-9. For details about
event A5, see section 5.5.4.6 "Event A5 (PCell becomes worse than threshold1 and neighbour
becomes better than threshold2)" in 3GPP TS 36.331 V10.1.0.
l Entering condition: Ms + Hys < Thresh1 and Mn + Ofn + Ocn - Hys > Thresh2
When event A5 is triggered, the eNodeB receives an event A5 from the UE.
l Leaving condition: Ms - Hys > Thresh1 or Mn + Ofn + Ocn + Hys < Thresh2
If the leaving condition of event A5 is met, the UE no longer reports event A5.
All parameters (other than thresholds) for event A5 are the same as those for event A4. For
details, see Table 4-10 and Table 4-12.
Table 4-13 and Table 4-14 describe Thresh1 and Thresh2 for event A5 that triggers inter-
frequency handover, respectively.
Blind event A2 can be used to trigger both coverage-based inter-frequency blind redirection
and inter-RAT blind handover. Coverage-based inter-frequency blind redirection and inter-
RAT blind handover share the same thresholds related to event A2. The working principles for
event A2 for coverage-based inter-frequency blind redirection and inter-RAT blind handover
are similar. For details about blind event A2, see Inter-RAT Mobility Management in
Connected Mode.
Target Selection
The target selection priority for blind handover is specified by
EutranInterFreqNCell.BlindHoPriority. If none of the neighboring cells are configured
with the blind handover priority (EutranInterFreqNCell.BlindHoPriority is set to 0), the
eNodeB performs measurement-based handover instead of blind handover.
Figure 4-10 shows target selection process for blind redirection.
l The EutranInterFreqNCell.BlindHoPriority parameter specifies the blind handover
priority.
l The UtranInterNFreq.ConnFreqPriority parameter specifies the frequency priority for
connected mode.
For a coverage-based blind redirection/blind handover, E-UTRAN TDD and E-UTRAN FDD
are considered as two independent systems, and the CnOperatorHoCfg.FirstRatPri and
CnOperatorHoCfg.SecondRatPri parameters specify the priorities of E-UTRAN TDD and
E-UTRAN FDD.
This feature is controlled by the following two options. The feature is activated only when
both the following options are selected.
Based on the QCIs of the services that are running on a UE, the eNodeB can divert the UE to
one or certain appropriate co-coverage E-UTRAN frequencies by means of this feature to
implement service steering.
Table 4-17 lists the triggering and stopping conditions for triggering/stopping inter-frequency
measurement and handover. This feature does not have a blind handover procedure.
All parameters (other than thresholds) for event A4 that triggers service-based inter-frequency
handovers are the same as those for event A4 that triggers coverage-based inter-frequency
handovers. Table 4-18 lists the thresholds related to event A4 that triggers service-based inter-
frequency handovers.
Service-based inter- When the triggering type This parameter is set for each QCI.
frequency RSRP is RSRP: The
triggering threshold Thresh = IntraRatHoComm.InterFreqHoA
InterFreqHoGroup.Int 4TrigQuan parameter determines
erFreqLoadBased- the threshold to be used.
HoA4ThdRSRP + l If
EutranInterNFreq.IfSr IntraRatHoComm.InterFreqH
vHoThdRsrpOffset oA4TrigQuan is set to BOTH,
two A4 events are delivered,
with one being RSRP-based and
the other RSRQ-based. When
the entering condition for either
of event A4 is met, the UE
reports event A4.
l When
IntraRatHoComm.InterFreqH
oA4TrigQuan is set to RSRP or
RSRQ, the eNodeB delivers a
measurement configuration
related to event A4 for which
the triggering quantity is RSRP
or RSRQ, respectively.
The
IntraRatHoComm.InterFreqHoA
4RprtQuan parameter determines
the reporting quantity to be
included in the measurement
reports after event A4 is triggered.
l When
IntraRatHoComm.InterFreqH
oA4RprtQuan is set to BOTH,
two A5 events are reported, with
one being RSRP-based and the
other RSRQ-based. An inter-
frequency handover is triggered
only when both measurement
quantities meet the condition
that the sum of the Mn, Ofn,
Ocn, and Hys values is greater
than or equal to the threshold
value.
l When
IntraRatHoComm.InterFreqH
oA4RprtQuan is set to
SAME_AS_TRIG_QUAN(Sa
me as Trig Quan), service-
Service-based inter- When the triggering type based measurement report type
frequency RSRQ is RSRQ: for event A4 is the same as the
triggering threshold Thresh = measurement triggering
InterFreqHoGroup.Int quantity.
erFreqLoadBased-
HoA4ThdRSRQ +
EutranInterNFreq.IfSr
vHoThdRsrqOffset
When UEs that trigger service-based inter-frequency measurement fail the outgoing handover
and continue to camp in the source eNodeB, the eNodeB reads the
CnOperatorQciPara.ServiceHoBearerPolicy parameter mapping each QCI.
l When this parameter is set to SERVICE_HO_QCI_NOT_ALLOWED(QCI Bear Not
Allowed), the bearer for the corresponding QCI is deleted.
l When this parameter is set to SERVICE_HO_QCI_ALLOWED(QCI Bear Allowed),
the bearer for the corresponding QCI is not deleted.
NOTE
As shown in Figure 4-11, band F1 is used to cover the urban area and band F2 is used to
cover the suburban area. If there are only a few buildings along the border between the urban
area and the suburban area, the RF signals from an F1 cell may be able to travel a long
distance (typically three times the distance between sites), causing overshoot coverage to an
F2 cell. The triangle area in the UE moving direction indicates overshoot coverage.
As there are restrictions on number of cells between two neighboring cells, Cell D cannot be
configured as a neighboring cell of Cell A. However, because of overshoot coverage of Cell
A, the UE cannot trigger coverage-based inter-frequency handover in Cell B and Cell C.
When the UE reaches Cell D and moves out of the overshoot coverage area, service drops will
occur because of the missing neighbor relationship. When distance-based inter-frequency
handover is enabled, the UE can be handed over to Cell B or Cell C in time to avoid service
drop. The deviation in the estimated distance between the UE and eNodeB is about 100 to 150
meters.
NOTE
Obtaining the distance between the UE and the eNodeB is dependent on the uplink timing advance (TA).
The eNodeB measures the TA of a UE and sends the TA value to the UE through a timing advance
command. The TA accuracy is 16 Ts.
Ts is the minimum time unit at the physical layer in LTE. The formula for calculating Ts is as follows: Ts
= 1/(15000 x 2048)s = 32.55 ns.
The formula for calculating the distance in a distance-based inter-frequency handover is as follows: 16
Ts/2 x Radio transmitting speed. That is, 16 x 32.55 ns /2 x 3 x 10^8 m/s = 78.12 m.
Table 4-19 lists the triggering and stopping conditions for triggering/stopping measurement
and handover during a distance-based inter-frequency handover. Blind handover is not applied
to distance-based inter-frequency handover.
Table 4-19 Events for triggering/stopping measurement and handover during a distance-based
inter-frequency handover
Inter-frequency Event A4 -
handover
Table 4-21 Events for triggering/stopping measurement and blind handover during an UL-
quality-based inter-frequency handover
Procedure Subproce Triggering Events Stopping Events
dure
Inter- Event A4 -
frequency
handover
and includes other measurement gaps, the eNodeB does not reconfigure the measurement gap.
Otherwise, the eNodeB activates the measurement gap.
Parameters in the measurement configuration for UL-quality-based inter-frequency
measurement are the same as those for coverage-based inter-frequency measurement.
Triggering Events
If the UL quality for the UE further deteriorates but the eNodeB does not receive an event A4
measurement report, the eNodeB considers that service drops may occur due to the poor UL
quality. In this situation, the eNodeB performs blind redirection for the UE.
l The uplink MCS index is smaller than the CellHoParaCfg.UlBadQualHoMcsThd
parameter value.
l The difference between the actual uplink data transmission IBLER and the
CELLHOPARACFG.UlBadQualHoIblerThd parameter value is greater than 10%.
l The eNodeB fails to receive the measurement report for event A4.
When CellAlgoSwitch.VolteRedirectSwitch is turned on, services with QCI of 1 support
blind redirection in UL-quality-based inter-frequency handover. In this case, the cause
value in the release message sent from the eNodeB to the MME is the fixed value User
Inactivity.
Target Selection
The target selection process of UL-quality-based inter-frequency blind redirection is the same
as that of coverage-based inter-frequency blind redirection. For details, see 4.1.4 Blind
Redirection/Blind Handover.
Table 4-23 lists the triggering and stopping conditions for triggering/stopping
measurement and handover during a frequency-priority-based inter-frequency handover
in this scenario.
Inter- Event A4 -
frequency
handover
Events A1 and A2 are respectively used for triggering and stopping measurement and
blind handover.
– When the eNodeB receives an event A1 report, blind handover or inter-frequency
measurement is triggered as follows: Blind handover is triggered if it has been
enabled by selecting the FreqPriorIFBlindHOSwitch option of the
CellAlgoSwitch.FreqPriorityHoSwitch parameter.
– If blind handover is not enabled, the eNodeB delivers a measurement configuration
for event A4 to trigger inter-frequency measurement.
l It is recommended that the A2BasedFreqPriHoSwitch option of the
CellAlgoSwitch.FreqPriorityHoSwitch parameter be selected in multi-band different-
coverage networking scenarios. When the bands with different bandwidth have different
coverage, a frequency-priority-based inter-frequency handover can be performed so that
the band with higher bandwidth carries services when the network load is light.
Table 4-24 lists the triggering and stopping conditions for triggering/stopping
measurement and handover during a frequency-priority-based inter-frequency handover
in this scenario.
Inter- Event A4 -
frequency
handover
During bear setup and release, this condition can be used to determine whether to stop or re-
deliver event A1/A2 for triggering frequency-priority-based inter-frequency handover.
l The MlbBasedFreqPriHoSwitch option of the CellAlgoSwitch.FreqPriorityHoSwitch
parameter is selected but the cell does not trigger MLB.
l The LoadTriggerFreqPriHoSwitch option of the
CellAlgoSwitch.FreqPriorityHoSwitch parameter is selected, and the eNodeB detects a
cell that meets the following condition: Among its neighboring cells with the
EutranInterFreqNCell.OverlapInd parameter set to YES(YES), the load of certain
neighboring cells can be obtained through the X2 interface and the neighboring cells
have not triggered UE-number-based MLB.
l If the option is selected, the eNodeB sends measurement configuration for event A1
when the UE sets up an RRC connection, and sends measurement configuration for event
A2 after it receives an event A1 from the UE.
l If the option is deselected, the eNodeB sends measurement configuration for both event
A2 and event A1 when the UE sets up an RRC connection.
Freq Priority Based InterFreqHoGroup.Fre This parameter is set for each QCI.
Interfreq A1 RSRP qPriInterFreqHoA1Thd The
threshold Rsrp IntraRatHoComm.FreqPriInterFreq
HoA1TrigQuan parameter determines
the threshold to be used.
l If
IntraRatHoComm.FreqPriInterF
Freq Priority Based InterFreqHoGroup.Fre This parameter is set for each QCI.
Interfreq A2 RSRP qPriInterFreqHoA2Thd The
threshold Rsrp IntraRatHoComm.FreqPriInterFreq
HoA1TrigQuan parameter determines
the threshold to be used.
l If
IntraRatHoComm.FreqPriInterF
reqHoA1TrigQuan is set to
BOTH, two A2 events are
reported, with one being RSRP-
Freq Priority Based InterFreqHoGroup.Fre This parameter is set for each QCI.
Interfreq A2 RSRP qPriInterFreqHoA2Thd The
threshold Rsrp IntraRatHoComm.FreqPriInterFreq
HoA1TrigQuan parameter determines
the threshold to be used.
l If
IntraRatHoComm.FreqPriInterF
reqHoA1TrigQuan is set to
BOTH, two A2 events are
reported, with one being RSRP-
based and the other RSRQ-based.
When the entering condition for
number allowed by 3GPP specifications, the eNodeB contains random frequencies in the
measurement configuration.
l If EutranInterFreqNCell.BlindHoPriority is set to DISABLE(Disable), the selected
inter-frequency neighboring cells must have a frequency priority ranging from 17 to 32.
Only the frequencies of these cells are measured. The frequency priority is set by the
EutranInterFreqNCell.BlindHoPriority parameter. If the number of target frequencies
to be measured exceeds the maximum number allowed by 3GPP specifications, the
eNodeB sorts the frequencies according to the value of the
EutranInterFreqNCell.BlindHoPriority parameter and selects the frequencies of the
neighboring cells with high priorities.
Load Based Interfreq InterFreqHoGroup.Int This parameter is set for each QCI.
RSRP threshold erFreqLoadBased- The
HoA4ThdRSRP IntraRatHoComm.InterFreqHoA
1A2TrigQuan parameter determines
which triggering threshold is to be
used.
l When
IntraRatHoComm.InterFreqH
oA1A2TrigQuan is set to
BOTH, the eNodeB delivers a
measurement configuration
related to event A4 according to
the triggering quantity of the
reported event A2 or A1. When
the entering condition for either
of event A4 is met, the UE
reports event A4.
l When
IntraRatHoComm.InterFreqH
oA1A2TrigQuan is set to RSRP
or RSRQ, the eNodeB delivers a
measurement configuration
related to event A4 for which the
triggering quantity is RSRP or
RSRQ, respectively.
The
IntraRatHoComm.InterFreqHoA
4RprtQuan parameter determines
the reporting quantity to be included
in the measurement reports after
event A4 is triggered.
l When
IntraRatHoComm.InterFreqH
oA4RprtQuan is set to BOTH,
two A4 events are reported, with
one being RSRP-based and the
other RSRQ-based. An inter-
frequency handover is triggered
only when both measurement
quantities meet the condition
that the sum of the Mn, Ofn,
Ocn, and Hys values is greater
than or equal to the threshold
value.
l When
IntraRatHoComm.InterFreqH
oA4RprtQuan is set to
SAME_AS_TRIG_QUAN(Sa
me as Trig Quan), service-
based measurement report type
for event A4 is the same as the
measurement triggering quantity.
Target Selection
The target selection process of frequency-priority-based inter-frequency blind handover is the
same as that of coverage-based inter-frequency blind handover. For details, see 4.1.4 Blind
Redirection/Blind Handover.
In frequency-priority-based blind handover, the target inter-frequency neighboring cell must
have a blind-handover priority ranging from 17 to 32. The frequency priority is set by the
EutranInterFreqNCell.BlindHoPriority parameter.
If an inter-frequency neighboring cell is not configured with a blind-handover priority, the
subsequent processing depends on the setting of the
EutranInterNFreq.FreqPriBasedHoMeasFlag parameter.
l If EutranInterNFreq.FreqPriBasedHoMeasFlag is set to ENABLE(Enable),
measurement is performed. The frequency of the neighboring cell is a target frequency. If
the number of target frequencies to be measured exceeds the maximum number allowed
by 3GPP specifications, the eNodeB contains random frequencies in the measurement
configuration.
l If EutranInterNFreq.FreqPriBasedHoMeasFlag is set to DISABLE(Disable),
measurement is not performed.
perform services on the ultra-high-speed railway dedicated network, low speed UEs perform
services on the public network, and high speed UEs that are handed over from the dedicated
network can be handed over back to the dedicated network in time.
If there are duplicated cells in the UE history information, you can infer that ping-pong
handovers have occurred, and the periods of staying in these cells are not accumulated.
l Inter-frequencies supported by UE
l Inter-frequencies with EutranInterNfreq.InterFreqHighSpeedFlag not set to
LOW_SPEED
Before delivering the measurement configuration related to event A4, the eNodeB checks
whether the measurement gap has been activated. If the measurement gap has been activated
and includes other measurement gaps, the eNodeB does not reconfigure the measurement gap.
Otherwise, the eNodeB activates the measurement gap.
To prevent a large number of public network UEs from being handed over to the dedicated
network when the target frequencies for high speed UEs are set, you can use the following
configurations:
To prevent public network UEs from being redirected to the high speed frequencies, it is
recommended that EutranInterNFreq.ConnFreqPriority of this frequency be set to 0.
To prevent public network UEs from being reselected to the high speed frequencies, it is
recommended that EutranInterNFreq.CellReselPriorityCfgInd of this frequency be set to
NOT_CFG.
To prevent ping-pong handovers, the high speed frequencies with this function enabled cannot
serve as the target frequency for the following handovers:
l Frequency-priority-based handover
l Service-based inter-frequency handover
l For details about the SPID-specific handover back to the HPLMN policy, see Flexible
User Steering Feature Parameter Description.
5 Related Features
Impacted Features
None
Impacted Features
Feature ID Feature Name Impact Description
If other inter-frequency handover features need to be used for multiple frequencies with
Coverage Based Inter-frequency Handover enabled, event A4 thresholds for those inter-
frequency handover features must be properly set. The event A4 threshold for each type of
inter-frequency handover must be higher than the event A2 threshold for coverage-based
inter-frequency handover to ensure that a coverage-based inter-frequency measurement is not
triggered immediately after a UE is handed over to the target frequency.
Impacted Features
Feature ID Feature Name Impact Description
TDLBFD-00201804 Distance Based Inter- You are advised not to deploy different
frequency Handover inter-frequency handover features on
multiple neighboring frequencies.
TDLOFD-001050 Mobility between TDD- Otherwise, ping-pong handovers
LTE and FDD-LTE between frequencies may occur due to
differences in triggering conditions for
different types of inter-frequency
handovers.
If other inter-frequency handover
features need to be used for multiple
frequencies with Coverage Based Inter-
frequency Handover enabled, event A4
thresholds for those inter-frequency
handover features must be properly set.
The event A4 threshold for each type of
inter-frequency handover must be
higher than the event A2 threshold for
coverage-based inter-frequency
handover to ensure that a coverage-
based inter-frequency measurement is
not triggered immediately after a UE is
handed over to the target frequency.
Impacted Features
Feature ID Feature Name Impact Description
Impacted Features
None
6 Network Impact
After this function is enabled, UEs supporting inter-mode measurement but not supporting inter-mode
handover cannot be transferred to an inter-mode network through measurement-based redirection.
Enabling this function does not affect UEs supporting both inter-mode measurement and inter-mode
handover.
For details about the impact of each function on the network, see the corresponding section.
Network Performance
Coverage-based intra-frequency handovers reduce interference from intra-frequency
neighboring cells on an intra-frequency network, decreasing the service drop rate.
Network Performance
With coverage-based inter-frequency handovers, the coverage in areas with weak LTE
coverage or coverage holes can be supplemented by inter-frequency neighboring cells,
decreasing the call drop rate.
The inter-frequency measurement priority control function allows VoIP UEs to be handed
over to the optimal frequency. This reduces the number of handovers of VoIP UEs during
continuous mobility. It is required that the frequency with the best signal quality can be
measured by VoIP UEs. Otherwise, VoIP UEs experience service drops due to lack of
measurements on neighboring cells on such a frequency. When this function is enabled, VoIP
UEs are concentrated in the cells on the frequency with the best signal quality. If the
bandwidth of such a frequency is small, the VoIP capacity may be limited.
Network Performance
No impact.
Network Performance
No impact.
Network Performance
Seamless co-existence between TDD and FDD E-UTRAN improves the network performance
and end user experience.
7 Engineering Guidelines
This chapter provides engineering guidelines for mobility management in connection mode.
7.1.3 Requirements
Operating Environment
Coverage-based intra-frequency handovers have no requirements for operating environment.
Transmission Networking
Coverage-based intra-frequency handovers have no requirements for transmission
networking.
License
Coverage-based intra-frequency handovers have no requirements for licenses.
Required Data
This section describes the data required for configuring neighbor relationships with intra-
frequency E-UTRAN cells.
(Optional) The following table describes the parameters that must be set in the
EutranExternalCell MO to configure an external E-UTRAN cell. This MO is required only
if an intra-frequency neighboring cell is under a different eNodeB from the local cell.
(Optional) The following table describes the parameters that must be set in the
EutranExternalCellPlmn MO to configure an additional PLMN ID (representing a
secondary operator) for an external E-UTRAN cell.
Share EutranExter Radio This parameter specifies the MCC of the secondary
mobile nalCellPlmn. planning operator for the external E-UTRAN cell.
country ShareMcc (internal This parameter references the corresponding
code planning parameter defined in the CnOperator MO on the
) peer eNodeB.
Share EutranExter Radio This parameter specifies the MNC of the secondary
mobile nalCellPlmn. planning operator for the external E-UTRAN cell.
network ShareMnc (internal This parameter references the corresponding
code planning parameter defined in the CnOperator MO on the
) peer eNodeB.
(Optional) The following table describes the parameters that must be set in the
EutranExternalCell MO to configure the secondary band for an external E-UTRAN cell if a
multi-band cell is configured as the neighboring cell of an E-UTRAN cell.
The following table describes the parameters that must be set in the EutranIntraFreqNCell
MO to configure the neighbor relationship with an intra-frequency E-UTRAN cell.
Local cell EutranIntr Radio Ensure that this parameter has been set in a Cell
ID aFreqNCell planning MO.
.LocalCellI (internal
d planning
)
Mobile EutranIntr Radio This parameter specifies the MCC of the home
country aFreqNCell planning eNodeB of the intra-frequency neighboring E-
code .Mcc (internal UTRAN cell. If this neighboring E-UTRAN cell
planning works in RAN sharing mode, set this parameter to
) the MCC of the primary operator. This parameter
references the corresponding parameter defined in
the CnOperator MO on the peer eNodeB.
Mobile EutranIntr Radio This parameter specifies the MNC of the home
network aFreqNCell planning eNodeB of the neighboring E-UTRAN cell. If this
code .Mnc (internal neighboring E-UTRAN cell works in RAN sharing
planning mode, set this parameter to the MNC of the
) primary operator. This parameter references the
corresponding parameter defined in the
CnOperator MO on the peer eNodeB.
Scenario-specific Data
The following table describes the parameter that must be set in the ENodeBAlgoSwitch MO
to enable the coverage-based intra-frequency handover.
By default, the intra-frequency handover parameter group Group0 is used for services with all
QCIs. To apply different intra-frequency handover parameter groups to services based on the
QCI, the corresponding parameter group ID must be changed.
The following table describes the parameter that must be set in the CellStandardQci MO to
configure parameter groups for services with standard QCIs.
Local cell ID CellStandardQci.L Radio planning Ensure that this parameter has
ocalCellId (internal planning) been set in a Cell MO.
The following table describes the parameter that must be set in the CellExtendedQci MO to
configure parameter groups for services with extended QCIs.
The following table describes the parameter that must be set in the EutranIntraFreqNCell
MO to configure the measurement priorities for intra-frequency neighboring cells.
The following table describes the parameters that must be set in the ENodeBAlgoSwitch MO
to configure ReduceMeasCtrlMesNumSwitch.
7.1.4.2 Activation
This feature can be activated using the CME or MML commands.
----End
Step 1 Trace messages over the Uu interface on the U2000 client after UEs access the network.
Check the RRC_CONN_RECFG message. If the message contains measurement
configuration of event A3 for a coverage-based intra-frequency handover, you can infer that
coverage-based intra-frequency handover has been activated.
Step 2 Trace messages over the Uu interface while the UE is moving towards an intra-frequency
neighboring cell. Check the RRC_CONN_RECFG message, which is a handover command.
If the message contains target cell access information, you can infer that coverage-based intra-
frequency handover has been triggered.
----End
7.1.6 Deactivation
Table 7-1 lists the parameters related to feature deactivation.
preparation success rate is also low, check for abnormal neighboring cells according to
"Number of Incoming Handover Failures for Different Causes in a Cell" and optimize
abnormal cells.
NOTE
Local IntraFre Network Ensure that this parameter has been set in a Cell MO
cell ID qHoGro plan based on the network plan.
up.Local (negotiati
CellId on not
required)
Intrafreq IntraFre Network This parameter specifies the hysteresis for event A3
handover qHoGro plan associated with intra-frequency handover. A larger
hysteresi up.Intra (negotiati hysteresis value causes a lower probability of
s FreqHoA on not triggering event A3, affecting user experience. A
3Hyst required) smaller hysteresis value causes a higher probability of
triggering event A3 but also a higher probability of
incorrect handover decisions and ping-pong
handovers.
It is recommended that the default value be used. You
can suitably decrease the value in areas with slight
signal fluctuation.
Intrafreq IntraFre Network This parameter specifies the offset for event A3
handover qHoGro plan associated with intra-frequency handover. A larger
offset up.Intra (negotiati value causes a lower probability of triggering event
FreqHoA on not A3. A smaller value causes a higher probability.
3Offset required) It is recommended that you adjust the parameter
value based on the application scenario. Increase the
parameter value if premature intra-frequency
handovers occur. Decrease the parameter value if
delayed intra-frequency handovers occur.
Intrafreq IntraFre Network This parameter specifies the time-to-trigger for event
handover qHoGro plan A3 associated with intra-frequency handover. Setting
time to up.Intra (negotiati an appropriate triggering delay effectively reduces the
trigger FreqHoA on not average number of handovers and the number of
3TimeTo required) wrong handovers, preventing unnecessary handovers.
Trig The average number of handovers has a negative
correlation with the time-to-trigger. At the same time,
an excessively large value of the time-to-trigger
results in a high risk of service drops.
It is recommended that you adjust the parameter
value with
IntraFreqHoGroup.IntraFreqHoA3Offset based on
the application scenario. Increase the parameter value
if premature intra-frequency handovers occur.
Decrease the parameter value if delayed intra-
frequency handovers occur.
Measurem IntraRat Network plan This parameter specifies the number of intra-
ent report HoComm. (negotiation frequency or inter-frequency periodical
amount IntraRatH not required) measurement reports to be sent after the
oRprtAmo corresponding event is triggered. Set this
unt parameter to a larger value if the eNodeB
requires more measurement reports to make a
handover decision. An excessively large
parameter value, however, causes a waste of
air interface resources.
It is recommended that the default value be
used.
Intrafreq IntraRat Network plan This parameter specifies the interval between
measurem HoComm. (negotiation the reports that are triggered by event A3
ent report IntraFreq not required) associated with intra-frequency handover. A
interval HoRprtInt smaller value causes more measurement
erval reports and greater consumption of air
interface resources, but a higher probability
of triggering handovers. An excessively large
parameter value, however, causes a long
delay in retries and a low handover success
rate.
It is recommended that the default value be
used.
7.1.9 Troubleshooting
Fault Description
An eNodeB may not initiate a handover procedure upon receipt of an event A3 measurement
report.
Fault Handling
When this problem occurs, perform the following steps to determine whether it has occurred
because the target cell has not been configured as a neighboring cell:
Step 1 Check the messages over the Uu interface and locate the PCI of the neighboring cell in the
measurement report.
Step 2 Run the LST EUTRANEXTERNALCELL command to list all external E-UTRAN cells of
the eNodeB, run the LST CELL command to list all local cells of the eNodeB, and check
these lists for the cell whose PCI equals the PCI found in the previous step.
l If this cell can be found, go to Step 4.
l If this cell cannot be found, the target cell has not been configured as an external cell. To
solve this problem, go to Step 3.
Step 3 Find out the CGI of the cell whose PCI equals the PCI found in Step 1 in the command output
in Step 2. Then, run the ADD EUTRANINTRAFREQNCELL command to add the CGI to
the EutranIntraFreqNCell MO.
Step 4 Find out the CGI of the cell whose PCI equals the PCI found in Step 1 in the command output
in Step 2. Then, run the ADD EUTRANEXTERNALCELL and ADD
EUTRANINTRAFREQNCELL commands to add the CGI to the EutranExternalCell and
EutranIntraFreqNCell MOs, respectively.
----End
If the live network does not require inter-frequency networking, you can disable coverage-
based inter-frequency handover.
Collect UE information to determine whether the eNodeB needs to handle UEs that report an
abnormal frequency-supporting capability.
In addition, collect the information about the coverage at the inter-frequency handover area.
This information serves as a basis for setting the thresholds used to trigger events A1, A2, and
A4.
The event A2 threshold for coverage-based inter-frequency handover and the event A2
threshold for coverage-based inter-RAT handover can be separately set. If users expect
coverage-based inter-frequency handover to be triggered earlier than coverage-based inter-
RAT handover, the event A2 threshold for coverage-based inter-frequency handover must be
set to a value greater than the event A2 threshold for coverage-based inter-RAT handover.
7.2.3 Requirements
Operating Environment
None
Transmission Networking
None
License
The operator supporting inter-frequency handovers between TDD and FDD has purchased
and activated the license for the feature listed in the following table.
Required Data
This section describes the data required for configuring neighbor relationships with inter-
frequency E-UTRAN cells.
The following table describes the parameters that must be set in the EutranInterNFreq MO
to configure a neighboring E-UTRAN frequency.
Local cell ID EutranIn Radio planning Ensure that this parameter has been set in a
terNFreq. (Internal Cell MO.
LocalCell planning)
Id
NOTE
If an inter-frequency neighboring cell is a multi-band cell, the EARFCN in the secondary band also
needs to be added in the EutranInterNFreq MO. For details about the relationship between the band
and EARFCN, see section 5.7.3 in 3GPP TS 36.101 V10.2.1 (2011-04).
For details about multi-band cells, see Multiple Frequency Band Indicator.
(Optional) The following table describes the parameters that must be set in the
EutranExternalCell MO to configure an external E-UTRAN cell. This MO is required only
if an inter-frequency neighboring cell is under a different eNodeB from the local cell. For
details about the key parameters in this MO, see 7.1.4.1 Data Preparation.
(Optional) The following table describes the parameters that must be set in the
EutranExternalCellPlmn MO to configure an additional PLMN ID (representing a
secondary operator) for an external E-UTRAN cell. For details about the key parameters in
this MO, see 7.1.4.1 Data Preparation.
(Optional) The following table describes the parameters that must be set in the
EutranExternalCell MO to configure the secondary band for an external E-UTRAN cell if a
multi-band cell is configured as the neighboring cell of an E-UTRAN cell. For details about
the key parameters in this MO, see 7.1.4.1 Data Preparation.
The following table describes the parameters that must be set in the EutranInterFreqNCell
MO to configure the neighbor relationship with an inter-frequency E-UTRAN cell.
Local cell EutranInterFreqN- Radio Ensure that this parameter has been
ID Cell.LocalCellId planning set in a Cell MO.
(Internal
planning)
Scenario-specific Data
The following table describes the parameter that must be set in the CellHoParaCfg MO to
configure coverage-based inter-frequency handover.
The following table describes the scenario-specific optimization parameters that must be set
in the ENodeBAlgoSwitch.
By default, the inter-frequency handover parameter group Group0 is used for services with all
QCIs. To apply different inter-frequency handover parameter groups to services based on the
QCI, the corresponding parameter group ID must be changed.
The following table describes the parameters that must be set in the CellStandardQci MO to
configure parameter groups for services with standard QCIs.
Local cell ID CellStandardQci.L Radio planning Ensure that this parameter has
ocalCellId (Internal been set in a Cell MO based
planning) on the network plan.
The following table describes the parameters that must be set in the CellExtendedQci MO to
configure parameter groups for services with extended QCIs.
The following table describes the parameters that must be set in the EutranInterFreqNCell
MO to configure blind handover priorities and measurement priorities for GERAN
neighboring cells.
The following table describes the parameters that must be set in the EutranInterNFreq MO
to configure the event for triggering a coverage-based inter-frequency handover and to
configure the frequency priority used during the selection of a target frequency for blind
redirection.
(Optional, required for only coverage-based inter-frequency handovers) The following table
describes the parameters that must be set in the CnOperatorHoCfg MO to configure the
RSRP threshold offset and priorities for TDD/FDD frequencies during the selection of the
target cells for coverage-based inter-frequency handovers.
LTE TDD CnOperato Default/ This parameter value plus the value of
inter-freq rHoCfg.Tdd recommended InterFreqHoGroup.InterFreqHoA2ThdR
A2 IfHoA2Thd value srp or
Threshold RsrpOffset InterFreqHoGroup.A3InterFreqHoA2Th
RSRP dRsrp is the offset of the RSRP threshold
Offset for LTE TDD inter-frequency measurement
event A2.
Set this parameter based on the actual
conditions.
NOTE
In the FDD and TDD co-site scenarios where
FDD cell policies differ from TDD cell policies,
you can configure the cell-level parameter
CellOpHoCfg.TddIfHoA2ThdRsrpOffset.
That is, when eNodeB- and cell-level
parameters coexist, the cell-level parameter is
used as the actual value.
LTE FDD CnOperato Default/ This parameter value plus the value of
inter-freq rHoCfg.Fdd recommended InterFreqHoGroup.InterFreqHoA2ThdR
A2 IfHoA2Thd value srp or
Threshold RsrpOffset InterFreqHoGroup.A3InterFreqHoA2Th
RSRP dRsrp is the offset of the RSRP threshold
Offset for LTE FDD inter-frequency measurement
event A2.
Set this parameter based on the actual
conditions.
NOTE
In the FDD and TDD co-site scenarios where
FDD cell policies differ from TDD cell policies,
you can configure the cell-level parameter
CellOpHoCfg.TddIfHoA2ThdRsrpOffset.
That is, when eNodeB- and cell-level
parameters coexist, the cell-level parameter is
used as the actual value.
(Optional, required for only coverage-based inter-frequency handovers) The following table
describes the parameters that must be set in the EutranNFreqRanShare MO to configure the
PLMN information in the RAN sharing configuration of the neighboring frequencies for
enabling inter-frequency blind handovers when there is no neighboring cells.
Local cell EutranNFreqRanS Radio Ensure that this parameter has been
ID hare.LocalCellId planning set in a Cell MO.
(Internal
planning)
(Optional, required only when inter-frequency measurement priority control is enabled for
VoIP UEs) The following table describes the parameters that must be set in the
CellAlgoSwitch MO to configure the VoIP measurement frequency priority switch.
7.2.4.2 Activation
This feature can be activated using the CME or MML commands.
----End
Step 1 Trace messages over the Uu interface on the U2000 client after UEs access the network.
Check the RRC_CONN_RECFG message. If the message contains measurement
configuration of events A1 and A2 for a coverage-based inter-frequency handover, you can
infer that coverage-based inter-frequency handover has been activated.
Step 2 Trace messages over the Uu interface while the UE is moving towards the cell edge. After the
eNodeB receives an A2-related measurement report from the UE, check the
RRC_CONN_RECFG message that contains the inter-frequency measurement configuration
and A4-related measurement report information.
Step 3 Trace messages over the Uu interface after the UE moves to the cell edge. Check the
RRC_CONN_RECFG message, which is a handover command, after the eNodeB receives an
A4-related measurement report from the UE. If the message contains target cell access
information, you can infer that coverage-based inter-frequency handover has been triggered.
----End
7.2.6 Deactivation
Table 7-2 lists the parameters related to feature deactivation.
NOTE
Local cell InterFreq Network plan Ensure that this parameter has been set in a
ID HoGroup. (negotiation Cell MO based on the network plan.
LocalCellI not required)
d
Interfreq InterFreq Network plan This parameter specifies the hysteresis for
A1A2 HoGroup. (negotiation events A1 and A2 for inter-frequency
hysteresis InterFreq not required) measurement. A larger value causes a lower
HoA1A2H probability of triggering event A1 or A2 for
yst inter-frequency measurement. A smaller
value causes a higher probability.
It is recommended that the default value be
used.
A4A5 InterFreq Network plan This parameter specifies the RSRP threshold
Based HoGroup. (negotiation for event A1 associated with inter-frequency
Interfreq InterFreq not required) measurement. A larger value causes a lower
A1 RSRP HoA1Thd probability of triggering event A1. A smaller
Threshold Rsrp value causes a higher probability.
The value of this parameter must be (usually
4 dB) greater than or equal to the sum of the
value of
InterFreqHoGroup.InterFreqHoA2ThdRsr
p and RSRP threshold offset for event A2 for
inter-frequency measurement (set in the
CnOperatorHoCfg MO).
A4A5 InterFreq Network plan This parameter specifies the RSRQ threshold
Based HoGroup. (negotiation for event A1 for inter-frequency
Interfreq InterFreq not required) measurement. A larger value causes a lower
A1 RSRQ HoA1Thd probability of triggering event A1. A smaller
Threshold Rsrq value causes a higher probability.
The value of this parameter must be (usually
2 dB) greater than or equal to the value of
InterFreqHoGroup.InterFreqHoA2ThdRsr
q.
A4A5 InterFreq Network plan This parameter specifies the RSRP threshold
Based HoGroup. (negotiation for event A2 for inter-frequency
Interfreq InterFreq not required) measurement. A larger value causes a lower
A2 RSRP HoA2Thd probability of triggering event A2. A smaller
Threshold Rsrp value causes a higher probability.
Set this parameter based on the actual
conditions. Usually, set this parameter to the
RSRP in the area where the UE throughput in
the serving cell is similar to that in the
neighboring cell.
A4A5 InterFreq Network plan This parameter specifies the RSRQ threshold
Based HoGroup. (negotiation for event A2 for inter-frequency
Interfreq InterFreq not required) measurement. A larger value causes a lower
A2 RSRQ HoA2Thd probability of triggering event A2. A smaller
Threshold Rsrq value causes a higher probability.
Set this parameter based on the actual
conditions. Usually, set this parameter to the
RSRQ in the area where the UE throughput in
the serving cell is similar to that in the
neighboring cell.
Interfreq InterFreq Network plan This parameter specifies the hysteresis for
handover HoGroup. (negotiation event A4. A larger value causes a lower
hysteresis InterFreq not required) probability of triggering event A4. A smaller
HoA4Hyst value causes a higher probability.
It is recommended that the default value be
used.
CoverageB InterFreq Network plan This parameter specifies the RSRP threshold
ased HoGroup. (negotiation for event A4 in a coverage-based, UL-
Interfreq InterFreq not required) quality-based, or distance-based handover, or
RSRP HoA4Thd in a SPID-based handover to the HPLMN. A
threshold Rsrp larger value causes a lower probability of
triggering event A4. A smaller value causes a
higher probability.
The value of this parameter must be greater
than the sum of the peer-end RSRP threshold
for event A2 for inter-frequency measurement
(set in the InterFreqHoGroup MO at the
peer eNodeB) and the RSRP threshold offset
for event A2 for inter-frequency measurement
for the higher-priority RAT(set in the
CnOperatorHoCfg MO at the peer eNodeB).
CoverageB InterFreq Network plan This parameter specifies the RSRQ threshold
ased HoGroup. (negotiation for event A4 in a coverage-based, UL-
Interfrq InterFreq not required) quality-based, or distance-based handover, or
RSRQ HoA4Thd in a SPID-based handover to the HPLMN. A
threshold Rsrq larger value causes a lower probability of
triggering event A4. A smaller value causes a
higher probability.
The value of this parameter must be greater
than or equal to the peer-end RSRQ threshold
for event A2 for inter-frequency measurement
set at the peer eNodeB (set in the
InterFreqHoGroup MO at the peer
eNodeB).
Interfreq InterFreq Network plan This parameter specifies the offset for event
A3 offset HoGroup. (negotiation A3 associated with inter-frequency handover.
InterFreq not required) It determines the border between the serving
HoA3Offs cell and the neighboring cell. If the parameter
et is set to a large value, an inter-frequency
handover is performed only when the signal
quality of the neighboring cell is significantly
better than that of the serving cell and other
triggering conditions are met.
It is recommended that you adjust the
parameter value based on the application
scenario. Increase the parameter value if
premature inter-frequency handovers occur.
Decrease the parameter value if delayed inter-
frequency handovers occur.
A3 based InterFreq Network plan This parameter specifies the RSRP threshold
interfreq HoGroup. (negotiation for event A1 associated with event-A3-
A1 RSRP A3InterFr not required) triggered inter-frequency handover. A
threshold eqHoA1T relatively large value results in a low
hdRsrp probability of stopping inter-frequency
measurements, whereas a relatively small
value results in a high probability.
The value of this parameter must be greater
than or equal to (usually 4 dB greater than)
the sum of
InterFreqHoGroup.A3InterFreqHoA2Thd
Rsrp and threshold offset for inter-frequency
measurement event A2 (set in the
CnOperatorHoCfg MO).
A3 based InterFreq Network plan This parameter specifies the RSRP threshold
Interfreq HoGroup. (negotiation for event A2 associated with event-A3-
A2 RSRP A3InterFr not required) triggered inter-frequency handover. A
threshold eqHoA2T relatively small value results in a low
hdRsrp probability of starting inter-frequency
measurements, whereas a relatively large
value results in a high probability.
Set this parameter based on actual conditions
to ensure that event-A3-triggered inter-
frequency handovers can occur timely.
Interfreq InterFreq Network plan This parameter indicates the RSRP threshold
A5 RSRP HoGroup. (negotiation 1 in the serving cell of event A5 for triggering
threshold 1 InterFreq not required) coverage-based inter-frequency handovers. A
HoA5Thd small value of this parameter leads to a low
1Rsrp probability of triggering event A5. A large
value of this parameter leads to a high
probability of triggering event A5.
It is recommended that you adjust the
parameter value based on the application
scenario. Increase the parameter value if too-
late inter-frequency handovers occur.
Interfreq InterFreq Network plan This parameter indicates the RSRQ threshold
A5 RSRQ HoGroup. (negotiation 1 in the serving cell of event A5 for triggering
threshold 1 InterFreq not required) coverage-based inter-frequency handovers. A
HoA5Thd small value of this parameter leads to a low
1Rsrq probability of triggering event A5. A large
value of this parameter leads to a high
probability of triggering event A5.
It is recommended that you adjust the
parameter value based on the application
scenario. Increase the parameter value if too-
late inter-frequency handovers occur.
VoIP Priority
The following table provides the parameter that must be set in the EutranInterNFreq MO to
adjust VoIP priority.
VoIP EutranIn Network plan This parameter is required when the inter-
Priority terNFreq. (negotiation frequency measurement frequency priority
VoipPriori required) control is enabled for VoIP UEs.
ty The priority is set in descending order
based on cell coverage status. The
frequency with better coverage is set with
higher priority. For frequencies with the
same coverage status, their priorities can be
set to the same value. If the neighboring
cells fill coverage holes of each other, the
priorities for the frequency of such
neighboring cells can be set to the same
value.
Assume that a site needs to be added to
resolve weak coverage in the network. The
frequency of Cell 1 in this site is F1, Cell 2
is a neighboring cell of Cell 1, and among
the neighboring frequencies of Cell 2, the
VoIP priority for F2 is the highest. In this
situation, the VoIP priority for F1 must be
reconfigured to be the same as the VoIP
priority for F2.
7.2.9 Troubleshooting
Fault Description
An event A4 measurement report may not be submitted when a UE moving toward the cell
edge experiences a call drop.
Troubleshooting
Perform the following steps to determine whether the handover parameters are set correctly:
Step 1 Check the messages over the S1 interface and locate the IE Cause in the
S1AP_UE_CONTEXT_REL_REQ message.
l If the value of this IE is radioNetwork:radio-connection-with-ue-lost, go to Step 2.
l If the value of this IE is not radioNetwork: radio-connection-with-ue-lost, the handover
parameters are set correctly. Contact Huawei technical support engineers.
Step 2 Check the messages over the Uu interface for A4 measurement reports in RRC_MEAS_RPRT
messages prior to RRC_CONN_REL messages.
l If such reports cannot be found, this problem is due to inappropriate settings of handover
parameters. Go to Step 3.
l If such reports can be found, contact Huawei engineers.
Step 3 Run the MOD INTERFREQHOGROUP command to reconfigure the following
parameters:
l A4A5 Based Interfreq A2 RSRP Threshold
l A4A5 Based Interfreq A2 RSRQ Threshold
l Interfreq handover hysteresis
l CoverageBased Interfreq RSRP threshold
l CoverageBased Interfrq RSRQ threshold
----End
7.3.3 Requirements
Operating Environment
None
Transmission Networking
None
License
The operator supporting inter-frequency handovers between TDD and FDD has purchased
and activated the license for the feature listed in the following table.
Required Data
The required data for this feature is the same as that for coverage-based inter-frequency
handover.
Scenario-specific Data
Service-based inter-frequency handover can be enabled only after coverage-based inter-
frequency handover is enabled. This section describes the required parameters except those
for coverage-based inter-frequency handover. For details on the required parameters for
The following table describes the parameters that must be set in the ServiceIfHoCfgGroup
MO to configure a service-based inter-frequency handover policy.
The following table describes the parameters that must be set in the ServiceIfDlEarfcnGrp
MO to configure a group of downlink EARFCNs to service-based inter-frequency handover
policy group.
NOTE
The following tables describe the parameter that must be set to configure inter-frequency
handover policy groups for services with standard or extended QCIs.
Parameters that must be set to configure parameter groups for services with standard QCIs are
in the CnOperatorStandardQci MO.
Parameters that must be set to configure parameter groups for services with extended QCIs
are in the CnOperatorExtendedQci MO.
The following table describes the parameters that must be set in the CellStandardQci MO to
configure priority for standard cell QCI.
The following table describes the parameter that must be set to configure the coordination
mechanism between MLB and this feature.
7.3.4.2 Activation
This feature can be activated using the CME or MML commands.
Step 4 Run the following commands to add neighbor relationships with inter-frequency E-UTRAN
cells:
1. ADD EUTRANINTERNFREQ
Step 6 Run the ADD SERVICEIFDLEARFCNGRP command to add target EARFCNs for
specified services.
----End
Step 1 Trace messages over the S1 interface after a UE accesses the network at the center of a cell in
the 2600 MHz band and sets up a handover-enabled dedicated bearer with a QCI of 2. Check
the S1AP_ERAB_SETUP_REQ message. If the message contains dedicated-bearer
configuration, you can infer that service-based inter-frequency handover has been activated.
Step 2 Trace messages over the Uu interface on the U2000 client. Check the RRC_CONN_RECFG
message that contains the A4-related inter-frequency measurement configuration for service-
based handover.
Step 3 Trace messages over the Uu interface on the U2000 client again. Check the
RRC_CONN_RECFG message, which is the handover command sent from the eNodeB after
the eNodeB receives an A4-related inter-frequency measurement report from the UE for a
service-based handover. If the message contains target cell access information, you can infer
that service-based inter-frequency handover has been triggered.
----End
7.3.6 Deactivation
Table 7-4 lists the parameters related to feature deactivation.
Local cell InterFreq Network plan Ensure that this parameter has been set in a
ID HoGroup. (negotiation Cell MO based on the network plan.
LocalCellI not required)
d
Load InterFreq Network plan This parameter specifies the RSRP threshold
Based HoGroup. (negotiation for event A4 for load-based, frequency-
Interfreq InterFreq not required) priority-based, and service-based inter-
RSRP LoadBase frequency handovers. A larger value causes a
threshold dHoA4Th lower probability of triggering event A4. A
dRsrp smaller value causes a higher probability.
The value of this parameter must be greater
than the sum of the peer-end RSRP threshold
for event A2 for inter-frequency measurement
(set in the InterFreqHoGroup MO at the
peer eNodeB) and the RSRP threshold offset
for event A2 for inter-frequency measurement
(set in the CnOperatorHoCfg MO at the
peer eNodeB).
Load InterFreq Network plan This parameter specifies the RSRQ threshold
Based HoGroup. (negotiation for event A4 for load-based, frequency-
Interfreq InterFreq not required) priority-based, and service-based inter-
RSRQ LoadBase frequency handovers. A larger value causes a
threshold dHoA4Th lower probability of triggering event A4. A
dRsrq smaller value causes a higher probability.
The value of this parameter must be greater
than or equal to the peer-end RSRQ threshold
for event A2 for inter-frequency measurement
set at the peer eNodeB (set in the
InterFreqHoGroup MO at the peer
eNodeB).
7.3.9 Troubleshooting
Fault Description
A UE with a service of QCIx may not be handed over to a cell working at frequency F1 after
the handover policy has been set to enable services with QCIx to be handed over to a cell
working at frequency F1.
Fault Handling
Perform the following steps to determine whether the handover parameters are set correctly:
Step 1 Check the messages over the S1 interface and locate the e-RABlevelQoSParameters IE in the
S1AP_INITIAL_CONTEXT_SETUP_REQ message and the S1AP_ERAB_SETUP_REQ
message (which may not exist).
l If QCIx is not contained in the e-RABlevelQoSParameters IE, ignore this fault and
perform the test again after verifying that the UE has set up a service with QCIx.
l If QCIx is contained in the e-RABlevelQoSParameters IE, check whether the UE has set
up a service which is not allowed to be handed over to a cell working at F1 because of its
QCI.
– If yes, perform the test again after the UE has stopped this service.
– If no, go to step 2.
Step 2 Check the messages over the Uu interface for A4 measurement reports in RRC_MEAS_RPRT
messages.
l If such reports cannot be found, this problem is due to inappropriate settings of handover
parameters. Go to Step 3.
l If such reports can be found, contact Huawei technical support engineers.
Step 3 Run the MOD INTERFREQHOGROUP command to reconfigure the following
parameters:
----End
7.4.3 Requirements
Operating Environment
None
Transmission Networking
None
License
The operator supporting inter-frequency handovers between TDD and FDD has purchased
and activated the license for the feature listed in the following table.
Required Data
The required data for this feature is the same as that for coverage-based inter-frequency
handover.
Scenario-specific Data
Speed-based inter-frequency handover can be enabled only after coverage-based inter-
frequency handover is enabled. This section describes the required parameters except those
for coverage-based inter-frequency handover.
To enable distance-based inter-frequency handovers, the corresponding switch must be turned
on and the measurement object type must be set to EUTRAN.
The following table describes the parameter that must be set in the CellAlgoSwitch MO to
enable distance-based handover.
The following table describes the parameters that must be set in the DistBasedHO MO to set
the measurement object type.
7.4.4.2 Activation
This feature can be activated using the CME or MML commands.
----End
Step 1 Trace messages over the Uu interface on the U2000 client after a UE accesses the network at
the center of a cell in the 2600 MHz band. Move the UE toward the cell edge. During the
movement, inter-frequency measurements are not triggered for a coverage-based handover
due to overshoot coverage, but the threshold for distance-based inter-frequency handover is
reached. Check the RRC_CONN_RECFG message. If the message contains measurement
configuration for a distance-based inter-frequency handover, you can infer that distance-based
inter-frequency handover has been activated.
Step 2 Trace messages over the Uu interface on the U2000 client again. Check the
RRC_CONN_RECFG message, which is the handover command sent from the eNodeB after
the eNodeB receives an A4-related inter-frequency measurement report from the UE for a
distance-based handover. If the message contains target cell access information, you can infer
that distance-based inter-frequency handover has been triggered.
----End
7.4.6 Deactivation
Table 7-6 lists the parameters related to feature deactivation.
Table 7-7 lists the counters related to distance-based inter-frequency and inter-mode
handover.
Local cell InterFreq Network plan Ensure that this parameter has been set in a
ID HoGroup. (negotiation Cell MO based on the network plan.
LocalCellI not required)
d
CoverageB InterFreq Network plan This parameter specifies the RSRP threshold
ased HoGroup. (negotiation for event A4 in a coverage-based, UL-
Interfreq InterFreq not required) quality-based, or distance-based handover, or
RSRP HoA4Thd in a SPID-based handover to the HPLMN. A
threshold Rsrp larger value causes a lower probability of
triggering event A4. A smaller value causes a
higher probability.
The value of this parameter must be greater
than the sum of the peer-end RSRP threshold
for event A2 for inter-frequency measurement
(set in the InterFreqHoGroup MO at the
peer eNodeB) and the RSRP threshold offset
for event A2 for inter-frequency measurement
(set in the CnOperatorHoCfg MO at the
peer eNodeB).
CoverageB InterFreq Network plan This parameter specifies the RSRQ threshold
ased HoGroup. (negotiation for event A4 in a coverage-based, UL-
Interfrq InterFreq not required) quality-based, or distance-based handover, or
RSRQ HoA4Thd in a SPID-based handover to the HPLMN. A
threshold Rsrq larger value causes a lower probability of
triggering event A4. A smaller value causes a
higher probability.
The value of this parameter must be greater
than or equal to the peer-end RSRQ threshold
for event A2 for inter-frequency measurement
set at the peer eNodeB (set in the
InterFreqHoGroup MO at the peer
eNodeB).
7.4.9 Troubleshooting
Fault Description
An event A4 measurement report may not be submitted when a UE moving toward the edge
of a cell that has overshoot coverage experiences a call drop.
Fault Handling
Perform the following steps to determine whether the handover parameters are set correctly:
Step 1 Check the messages over the S1 interface and locate the IE Cause in the
S1AP_UE_CONTEXT_REL_REQ message.
l If the value of this IE is radioNetwork:radio-connection-with-ue-lost, go to Step 2.
l If the value of this IE is not radioNetwork:radio-connection-with-ue-lost, the handover
parameters are set correctly. Contact Huawei technical support engineers.
Step 2 Check the messages over the Uu interface for A4 measurement reports in RRC_MEAS_RPRT
messages prior to RRC_CONN_REL messages.
l If such reports cannot be found, this problem is due to inappropriate settings of handover
parameters. Go to Step 3.
l If such reports can be found, contact Huawei technical support engineers.
----End
7.5.3 Requirements
Operating Environment
None
Transmission Networking
None
License
The operator supporting inter-frequency handovers between TDD and FDD has purchased
and activated the license for the feature listed in the following table.
Required Data
The required data for this feature is the same as that for coverage-based inter-frequency
handover.
Scenario-specific Data
Speed-based inter-frequency handover can be enabled only after coverage-based inter-
frequency handover is enabled. This section describes the required parameters except those
for coverage-based inter-frequency handover.
The following table describes the parameter that must be set in the ENodeBAlgoSwitch MO
to configure UL-quality-based inter-frequency handover.
7.5.4.2 Activation
This feature can be activated using the CME or MML commands.
----End
Step 1 Use a UE to access the network at the cell center in the 2600 MHz band. Then, move the UE
from the cell center to the cell edge. During this process, the uplink quality of the UE
becomes poor.
Step 2 Observe the user-level measurement result on the U2000 (choose Monitor > Signaling Trace
> Signaling Trace Management, and observe the value of BLER Monitoring in User
Performance Monitoring.)
l When the user uplink IBLER increases gradually, observe the messages traced over the
Uu interface. If the RRC_CONN_RECFG message from the eNodeB contains
measurement control information for the inter-frequency handover and the
RRC_CONN_RECFG message received by the eNodeB contains information of the
target cell for an inter-frequency handover, you can infer that UL-quality-based inter-
frequency handover has been activated.
l When the user uplink IBLER increases suddenly but has not reached 99%, observe the
messages traced over the Uu interface. If the RRC_CONN_REL message from the
eNodeB contains target frequency information, you can infer that UL-quality-based
inter-frequency handover has been activated.
----End
7.5.6 Deactivation
Table 7-8 lists the parameters related to feature deactivation.
Local cell InterFreq Network plan Ensure that this parameter has been set in a
ID HoGroup. (negotiation Cell MO based on the network plan.
LocalCellI not required)
d
CoverageB InterFreq Network plan This parameter specifies the RSRP threshold
ased HoGroup. (negotiation for event A4 in a coverage-based, UL-
Interfreq InterFreq not required) quality-based, or distance-based handover, or
RSRP HoA4Thd in a SPID-based handover to the HPLMN. A
threshold Rsrp larger value causes a lower probability of
triggering event A4. A smaller value causes a
higher probability.
The value of this parameter must be greater
than the sum of the peer-end RSRP threshold
for event A2 for inter-frequency measurement
(set in the InterFreqHoGroup MO at the
peer eNodeB) and the RSRP threshold offset
for event A2 for inter-frequency measurement
(set in the CnOperatorHoCfg MO at the
peer eNodeB).
CoverageB InterFreq Network plan This parameter specifies the RSRQ threshold
ased HoGroup. (negotiation for event A4 in a coverage-based, UL-
Interfrq InterFreq not required) quality-based, or distance-based handover, or
RSRQ HoA4Thd in a SPID-based handover to the HPLMN. A
threshold Rsrq larger value causes a lower probability of
triggering event A4. A smaller value causes a
higher probability.
The value of this parameter must be greater
than or equal to the peer-end RSRQ threshold
for event A2 for inter-frequency measurement
set at the peer eNodeB (set in the
InterFreqHoGroup MO at the peer
eNodeB).
7.5.9 Troubleshooting
Fault Description
An event A4 measurement report may not be submitted when a UE moving toward the cell
edge experiences a call drop.
Fault Handling
Perform the following steps to determine whether the handover parameters are set correctly:
Step 1 Check the messages over the S1 interface and locate the IE Cause in the
S1AP_UE_CONTEXT_REL_REQ message.
l If the value of this IE is radioNetwork:radio-connection-with-ue-lost, go to Step 2.
l If the value of this IE is not radioNetwork:radio-connection-with-ue-lost, the handover
parameters are set correctly. Contact Huawei technical support engineers.
Step 2 Check the messages over the Uu interface for A4 measurement reports in RRC_MEAS_RPRT
messages prior to RRC_CONN_REL messages.
l If such reports cannot be found, this problem is due to inappropriate settings of handover
parameters. Go to Step 3.
l If such reports can be found, contact Huawei technical support engineers.
----End
Collect information about the coverage of different bands. This information serves as a basis
for setting the thresholds used to trigger events A1, A2, and A4.
7.6.3 Requirements
Operating Environment
None
Transmission Networking
None
License
The operator has purchased and activated the license for the features listed in the following
table.
The operator has purchased and activated the license for mobility between TDD-LTE and
FDD-LTE listed in the following table.
l Network plan (negotiation not required): parameter values planned and set by the
operator
l Network plan (negotiation required): parameter values planned by the operator and
negotiated with the EPC or peer transmission equipment
l User-defined: parameter values set by users
Required Data
The required data for this feature is the same as that for coverage-based inter-frequency
handover.
Scenario-specific Data
Speed-based inter-frequency handover can be enabled only after coverage-based inter-
frequency handover is enabled. This section describes the required parameters except those
for coverage-based inter-frequency handover.
The following table describes the parameter that must be set in the CellAlgoSwitch MO to
configure frequency-priority-based inter-frequency handover.
The following table describes the parameter that must be set in the EutranInterFreqNCelll
MO to configure the blind handover priorities for inter-frequency neighboring cells.
The following table describes the parameter that must be set to configure the coordination
mechanism between MLB and this feature.
7.6.4.2 Activation
This feature can be activated using the CME or MML commands.
It is recommended that the measurement-based mode be used. The blind handover mode is used only
when operators ensure that there is coverage under the target frequency.
Step 3 Run the following commands to add neighbor relationships with inter-frequency E-UTRAN
cells: Set EutranInterFreqNCell.BlindHOPriority to a value ranging from 17 to 32.
1. ADD EUTRANINTERNFREQ
2. ADD EUTRANINTERFREQNCELL
----End
Step 1 Trace messages over the Uu interface on the U2000 client after UEs access the network at the
center of a 900 MHz cell. Check the RRC_CONN_RECFG message. If the message contains
measurement configuration for a frequency-priority-based inter-frequency handover, you can
infer that frequency-priority-based inter-frequency handover has been activated.
Step 2 In the multi-band same-coverage networking scenario, the eNodeB sends a measurement
configuration for event A4 to start the gap-assisted inter-frequency measurement after
receiving a measurement report for event A1 from the UE. In the multi-band different-
coverage networking scenario, the eNodeB sends a measurement configuration for event A4
to start the gap-assisted inter-frequency measurement after receiving a measurement report for
event A2 from the UE.
Step 3 Trace messages over the Uu interface on the U2000 client. After receiving a measurement
report for event A4 from the UE, the eNodeB sends an RRC_CONN_RECFG message to the
UE for a frequency-priority-based inter-frequency handover. Check the RRC_CONN_RECFG
message. If the message contains target cell access information, you can infer that frequency-
priority-based inter-frequency handover has been triggered.
----End
7.6.6 Deactivation
Table 7-10 lists the parameters related to feature deactivation.
Table 7-11 lists the counters related to frequency-priority-based inter-frequency and inter-
mode handover.
Local cell InterFreqHo Network Ensure that this parameter has been set in a
ID Group.Local plan Cell MO based on the network plan.
CellId (negotiatio
n not
required)
Load Based InterFreqHo Network This parameter specifies the RSRP threshold
Interfreq Group.Inter plan for event A4 for load-based, frequency-
RSRP FreqLoadBa (negotiatio priority-based, and service-based inter-
threshold sedHoA4Thd n not frequency handovers. A larger value causes a
Rsrp required) lower probability of triggering event A4. A
smaller value causes a higher probability.
The value of this parameter must be greater
than the sum of the peer-end RSRP threshold
for event A2 for inter-frequency measurement
(set in the InterFreqHoGroup MO at the
peer eNodeB) and the RSRP threshold offset
for event A2 for inter-frequency measurement
(set in the CnOperatorHoCfg MO at the
peer eNodeB).
Load Based InterFreqHo Network This parameter specifies the RSRQ threshold
Interfreq Group.Inter plan for event A4 for load-based, frequency-
RSRQ FreqLoadBa (negotiatio priority-based, and service-based inter-
threshold sedHoA4Thd n not frequency handovers. A larger value causes a
Rsrq required) lower probability of triggering event A4. A
smaller value causes a higher probability.
The value of this parameter must be greater
than the sum of the peer-end RSRQ threshold
for event A2 for inter-frequency measurement
(set in the InterFreqHoGroup MO at the
peer eNodeB) and the RSRQ threshold offset
for event A2 for inter-frequency measurement
(set in the CnOperatorHoCfg MO at the
peer eNodeB).
Intra-RAT Handover
Intra-RAT handover parameters are contained in the IntraRatHoComm MO.
7.6.9 Troubleshooting
Fault Description
An eNodeB does not initiate a handover procedure upon receipt of an event A1 measurement
report.
Troubleshooting
Perform the following steps to determine whether the blind handover priorities for
neighboring cells are accurate:
----End
7.7.3 Requirements
Operating Environment
None
Transmission Networking
None
License
The operator supporting inter-frequency handovers between TDD and FDD has purchased
and activated the license for the feature listed in the following table.
l Network plan (negotiation not required): parameter values planned and set by the
operator
l Network plan (negotiation required): parameter values planned by the operator and
negotiated with the EPC or peer transmission equipment
l User-defined: parameter values set by users
Required Data
The required data for this feature is the same as that for coverage-based inter-frequency
handover.
Scenario-specific Data
This feature can be enabled only after coverage-based inter-frequency handover is enabled.
This section describes the required parameters except those for coverage-based inter-
frequency handover.
The following table describes the parameter that must be set in the CellAlgoSwitch MO to
configure high speed UE handover frequency-based redirection. It also describes the
parameters that must be set in the CellHoParaCfg MO to configure the thresholds on the
number of handover times and on the accumulated handover duration.
High CellAlg Radio This parameter specifies whether to enable UEs in high
Speed oSwitch plannin mobility to be redirected to high speed frequencies. Select
Optimi .HighSp g the HighSpeedUserRedirectSwitch check box for public
zed eedSch (negoti network cells along the ultra-high-speed railway.
Switch OptSwit ation
ch with
the
peer)
Speed CELLH Engine This parameter specifies the threshold on the accumulated
Evaluat OPARA ering periods in the lately visited cells, the number of which is
ed CFG.Sp design specified by CELLHOPARACFG.SpeedEvaluatedNum.
Period eedEval
uatedPe
riod
When ANR is disabled, inter-frequency neighboring cells do not need to be configured for
high speed frequencies.
When ANR is enabled, set the blind handover priority for high-speed inter-frequency
neighboring cells to 0 and configure the no handover flag. The following table describes the
parameter that must be set in the EutranInterFreqNCell MO to configure the blind handover
priorities for inter-frequency neighboring cells.
The following table describes the parameter that must be set in the EutranInterNFreq MO to
configure the inter-frequency cell reselection priority configuration indicator and connect
frequency priority for high-speed railway.
7.7.4.2 Activation
This feature can be activated using the CME or MML commands.
----End
//Forbidding public network users from being handed over to high-speed railway neighboring
cells
MOD EUTRANINTERFREQNCELL: LocalCellId=0, Mcc="460", Mnc="20", eNodeBId=123,
CellId=1, NoHoFlag=FORBID_HO_ENUM;
//Forbidding public network users from being reselected to high-speed railway neighboring
cells
MOD EUTRANINTERNFREQ: LocalCellId=0, DlEarfcn=2860,
CellReselPriorityCfgInd=NOT_CFG;
//Adding the thresholds on the number of visited cells and accumulated duration for a UE to
stay in these cells
MOD CELLHOPARACFG: LocalCellId=0, SpeedEvaluatedPeriod=HS_30S,
SpeedEvaluatedNum=3;
Step 1 In a high-mobility scenario, enable a high-mobility UE to access the public network. The
RRC_CONN_RECFG message in the Uu interface tracing result indicates that high-mobility
frequencies are delivered in the A4 measurement control information for high-speed UE
handover frequency-based redirection. This means that the high speed UE handover
frequency-based redirection feature has been activated.
Step 2 Check the Uu interface tracing messages. After the A4 measurement report is sent to the
eNodeB, the eNodeB delivers a redirection command to instruct the high-speed UE to be
redirected to a dedicated network cell. In the RRC_RELEASE message delivered from the
public network cell for redirection, the target frequency information is available, indicating
that high speed UE handover frequency-based redirection has been activated.
----End
7.7.6 Deactivation
Table 7-12 lists the parameters related to feature deactivation.
Local cell InterFreqHo Network Ensure that this parameter has been set in a
ID Group.Local plan Cell MO based on the network plan.
CellId (negotiatio
n not
required)
Load Based InterFreqHo Network This parameter specifies the RSRP threshold
Interfreq Group.Inter plan for event A4 for load-based, frequency-
RSRP FreqLoadBa (negotiatio priority-based, and service-based inter-
threshold sedHoA4Thd n not frequency handovers. A larger value causes a
Rsrp required) lower probability of triggering event A4. A
smaller value causes a higher probability.
The value of this parameter must be greater
than the sum of the peer-end RSRP threshold
for event A2 for inter-frequency measurement
(set in the InterFreqHoGroup MO at the
peer eNodeB) and the RSRP threshold offset
for event A2 for inter-frequency measurement
(set in the CnOperatorHoCfg MO at the peer
eNodeB).
Load Based InterFreqHo Network This parameter specifies the RSRQ threshold
Interfreq Group.Inter plan for event A4 for load-based, frequency-
RSRQ FreqLoadBa (negotiatio priority-based, and service-based inter-
threshold sedHoA4Thd n not frequency handovers. A larger value causes a
Rsrq required) lower probability of triggering event A4. A
smaller value causes a higher probability.
The value of this parameter must be greater
than the sum of the peer-end RSRQ threshold
for event A2 for inter-frequency measurement
(set in the InterFreqHoGroup MO at the
peer eNodeB) and the RSRQ threshold offset
for event A2 for inter-frequency measurement
(set in the CnOperatorHoCfg MO at the peer
eNodeB).
7.7.9 Troubleshooting
Fault Description
The eNodeB does not initiate a redirection procedure after receiving a measurement report for
high speed UE handover frequency-based redirection.
Fault Handling
Perform the following steps to determine whether the blind handover priorities for
neighboring cells are accurate:
----End
8 Parameters
CellAlg FreqPrio MOD LOFD-0 Intra- Meaning: Indicates whether to enable frequency-
oSwitch rityHoS CELLA 70215 / LTE priority-based inter-frequency handover algorithms.
witch LGOSW TDLOF User This parameter includes the following options:
ITCH D-07021 Number FreqPriorIFHOSwitch: Frequency-priority-based
LST 5 Load inter-frequency handover is applicable when the two
CELLA Balancin E-UTRAN frequencies provide the same coverage and
LGOSW g one frequency is preferred for carrying services. If this
ITCH option is selected, the frequency-priority-based inter-
frequency handover will be triggered even when the
serving cell provides a good signal quality. If this
option is deselected, the frequency-priority-based
inter-frequency handover is disabled, and the inter-
frequency handover can be triggered only when other
conditions are met. FreqPriorIFBlindHOSwitch: If
this option is selected, frequency-priority-based inter-
frequency handovers are performed in a blind manner.
If this option is deselected, frequency-priority-based
inter-frequency handovers are performed based on
measurements. This option takes effect only when the
FreqPriorIFHOSwitch option is selected.
MlbBasedFreqPriHoSwitch: Indicates whether to
enable frequency-priority-based inter-frequency
handovers when MLB is triggered. If this option is
selected, the eNodeB stops performing frequency-
priority-based inter-frequency handovers on UEs that
newly access the cell with MLB enabled. If this option
is deselected, the eNodeB continues performing
frequency-priority-based inter-frequency handovers
on UEs that newly access the cell with MLB enabled.
This option takes effect only when the
FreqPriorIFHOSwitch option is selected.
EutranIn IfSrvHo ADD LBFD-0 Service Meaning: Indicates the offset of the RSRP threshold
terNFre ThdRsrp EUTRA 0201805 Based for triggering service-based inter-frequency
q Offset NINTE / Inter- handovers. In service-based inter-frequency
RNFRE TDLBF frequenc handovers, the eNodeB delivers the RSRP threshold
Q D-00201 y for event A4 or A5 to UEs, which is equal to the sum
MOD 805 Handov of the InterFreqLoadBasedHoA4ThdRsrp and
EUTRA TDLOF er IfSrvHoThdRsrpOffset parameter values. In service-
NINTE D-07022 Service request-based inter-frequency handovers, the eNodeB
RNFRE 8 Request delivers the RSRP threshold for event A4 or A5 to
Q Based UEs, which is equal to the sum of the
Inter- SrvReqHoA4ThdRsrp and IfSrvHoThdRsrpOffset
LST parameter values. If the RSRP threshold for event A4
EUTRA frequenc
y or A5 is less than the minimum RSRP value, the
NINTE minimum value is delivered instead. If the RSRP
RNFRE Handov
er threshold for event A4 or A5 is greater than the
Q maximum RSRP value, the maximum value is
delivered instead.
GUI Value Range: -20~20
Unit: dBm
Actual Value Range: -20~20
Default Value: 0
EutranIn IfSrvHo ADD LBFD-0 Service Meaning: Indicates the offset of the RSRQ threshold
terNFre ThdRsrq EUTRA 0201805 Based for triggering service-based inter-frequency
q Offset NINTE / Inter- handovers. In service-based inter-frequency
RNFRE TDLBF frequenc handovers, the eNodeB delivers the RSRQ threshold
Q D-00201 y for event A4 or A5 to UEs, which is equal to the sum
MOD 805 Handov of the InterFreqLoadBasedHoA4ThdRsrq and
EUTRA TDLOF er IfSrvHoThdRsrqOffset parameter values. In service-
NINTE D-07022 Service request-based inter-frequency handovers, the eNodeB
RNFRE 8 Request delivers the RSRQ threshold for event A4 or A5 to
Q Based UEs, which is equal to the sum of the
Inter- SrvReqHoA4ThdRsrq and IfSrvHoThdRsrqOffset
LST parameter values. If the RSRQ threshold for event A4
EUTRA frequenc
y or A5 is less than the minimum RSRQ value, the
NINTE minimum value is delivered instead. If the RSRQ
RNFRE Handov
er threshold for event A4 or A5 is greater than the
Q maximum RSRQ value, the maximum value is
delivered instead.
GUI Value Range: -20~20
Unit: 0.5dB
Actual Value Range: -10~10
Default Value: 0
ENodeB HoAlgo MOD LBFD-0 Coverag Meaning: Indicates whether to enable handover
AlgoSwi Switch ENODE 0201801 e Based algorithms. This parameter includes the following
tch BALGO / Intra- options: IntraFreqCoverHoSwitch: If this option is
SWITC TDLBF frequenc selected, coverage-based intra-frequency handovers
H D-00201 y are enabled to ensure service continuity. If this option
LST 801 Handov is deselected, coverage-based intra-frequency
ENODE LBFD-0 er handovers are disabled. InterFreqCoverHoSwitch: If
BALGO 0201802 Distance this option is selected, coverage-based inter-frequency
SWITC / Based handovers are enabled to ensure service continuity. If
H TDLBF Inter- this option is deselected, coverage-based inter-
D-00201 frequenc frequency handovers are disabled. UtranCsfbSwitch:
802 y If this option is selected, CSFB to UTRAN is enabled
Handov and UEs can fall back to UTRAN. If this option is
LBFD-0 deselected, CSFB to UTRAN is disabled.
er
0201804 GeranCsfbSwitch: If this option is selected, CSFB to
/ Service
GERAN is enabled and UEs can fall back to GERAN.
TDLBF Based
If this option is deselected, CSFB to GERAN is
D-00201 Inter-
disabled. Cdma1xRttCsfbSwitch: If this option is
804 frequenc
selected, CSFB to CDMA2000 1xRTT is enabled and
y
LBFD-0 UEs can fall back to CDMA2000 1xRTT. If this
Handov
0201805 option is deselected, CSFB to CDMA2000 1xRTT is
er
/ disabled. UtranServiceHoSwitch: If this option is
TDLBF CS selected, service-based handovers to UTRAN are
D-00201 Fallback enabled and UEs using a specific type of services can
805 to be handed over to UTRAN. If this option is
UTRAN deselected, service-based handovers to UTRAN are
LOFD-0
CS disabled. GeranServiceHoSwitch: If this option is
01033 /
Fallback selected, service-based handovers to GERAN are
TDLOF
to enabled and UEs using a specific type of services can
D-00103
GERAN be handed over to GERAN. If this option is
3
CS deselected, service-based handovers to GERAN are
LOFD-0 Fallback disabled. CdmaHrpdServiceHoSwitch: If this option is
01034 / to selected, service-based handovers to CDMA2000
TDLOF CDMA2 HRPD cells are enabled and UEs using a specific type
D-00103 000 of services can be handed over to CDMA2000 HRPD
4 1xRTT cells. If this option is deselected, service-based
LOFD-0 handovers to CDMA2000 HRPD cells are disabled.
Flash
01035 / This option is not supported in this version.
CS
TDLOF Cdma1xRttServiceHoSwitch: If this option is
Fallback
D-00103 selected, service-based handovers to CDMA2000
to
5 1xRTT are enabled and UEs using a specific type of
UTRAN
services can be handed over to CDMA2000 1xRTT. If
LOFD-0 Flash this option is deselected, service-based handovers to
01052 / CS CDMA2000 1xRTT are disabled. This option is not
TDLOF Fallback supported in this version. UlQualityInterRATHoS-
D-00105 to witch: If this option is selected, UL-quality-based
2 GERAN inter-RAT handovers are enabled and UEs can be
LOFD-0 CS handed over to inter-RAT cells to ensure service
01053 / Fallback
Cell QoffsetF ADD LBFD-0 Coverag Meaning: Indicates the specific frequency offset of the
req CELL 0201801 e Based serving cell. This parameter is contained in the
MOD LBFD-0 Intra- measurement control information and is related to the
CELL 0201803 frequenc handover difficulty between the serving cell and the
y neighboring cell. For details, see 3GPP TS 36.331.
LST TDLBF Handov
CELL D-00201 GUI Value Range: dB-24(-24dB), dB-22(-22dB),
er dB-20(-20dB), dB-18(-18dB), dB-16(-16dB),
8
Cell dB-14(-14dB), dB-12(-12dB), dB-10(-10dB),
TDLBF Selectio dB-8(-8dB), dB-6(-6dB), dB-5(-5dB), dB-4(-4dB),
D-00201 n and dB-3(-3dB), dB-2(-2dB), dB-1(-1dB), dB0(0dB),
802 Re- dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB),
TDLBF selection dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB),
D-00201 Mobility dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB),
804 Manage dB20(20dB), dB22(22dB), dB24(24dB)
TDLBF ment Unit: dB
D-00201 Coverag Actual Value Range: dB-24, dB-22, dB-20, dB-18,
805 e Based dB-16, dB-14, dB-12, dB-10, dB-8, dB-6, dB-5, dB-4,
TDLOF Inter- dB-3, dB-2, dB-1, dB0, dB1, dB2, dB3, dB4, dB5,
D-00101 frequenc dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20,
9 y dB22, dB24
TDLOF Handov
Default Value: dB0(0dB)
D-00104 er
3 Distance
Based
TDLOF
Inter-
D-00107
frequenc
2
y
TDLOF Handov
D-00102 er
0
Service
TDLOF Based
D-00104 Inter-
6 frequenc
TDLOF y
D-00107 Handov
3 er
PS Inter-
RAT
Mobility
between
E-
UTRAN
and
UTRAN
Service
based
Inter-
RAT
handove
r to
UTRAN
Distance
based
Inter-
RAT
handove
r to
UTRAN
PS Inter-
RAT
Mobility
between
E-
UTRAN
and
GERAN
Service
based
Inter-
RAT
handove
r to
GERAN
Distance
based
Inter-
RAT
handove
r to
GERAN
Cell CellSpe ADD LBFD-0 Coverag Meaning: Indicates the cell specific offset for the
cificOffs CELL 0201801 e Based serving cell. It affects the probability of triggering
et MOD / Intra- handovers from the serving cell to its neighboring
CELL TDLBF frequenc cells. A smaller value of this parameter leads to a
D-00201 y higher probability. For details, see 3GPP TS 36.331.
LST 801 Handov
CELL GUI Value Range: dB-24(-24dB), dB-22(-22dB),
TDLBF er dB-20(-20dB), dB-18(-18dB), dB-16(-16dB),
D-00201 Mobility dB-14(-14dB), dB-12(-12dB), dB-10(-10dB),
8 Manage dB-8(-8dB), dB-6(-6dB), dB-5(-5dB), dB-4(-4dB),
TDLBF ment dB-3(-3dB), dB-2(-2dB), dB-1(-1dB), dB0(0dB),
D-00201 Coverag dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB),
802 e Based dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB),
Inter- dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB),
TDLBF dB20(20dB), dB22(22dB), dB24(24dB)
D-00201 frequenc
804 y Unit: dB
Handov Actual Value Range: dB-24, dB-22, dB-20, dB-18,
TDLBF er
D-00201 dB-16, dB-14, dB-12, dB-10, dB-8, dB-6, dB-5, dB-4,
805 Distance dB-3, dB-2, dB-1, dB0, dB1, dB2, dB3, dB4, dB5,
Based dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20,
TDLOF Inter- dB22, dB24
D-00101 frequenc
9 Default Value: dB0(0dB)
y
TDLOF Handov
D-00104 er
3 Service
TDLOF Based
D-00107 Inter-
2 frequenc
TDLOF y
D-00102 Handov
0 er
TDLOF PS Inter-
D-00104 RAT
6 Mobility
between
TDLOF E-
D-00107 UTRAN
3 and
UTRAN
Service
based
Inter-
RAT
handove
r to
UTRAN
Distance
based
Inter-
RAT
handove
r to
UTRAN
PS Inter-
RAT
Mobility
between
E-
UTRAN
and
GERAN
Service
based
Inter-
RAT
handove
r to
GERAN
Distance
based
Inter-
RAT
handove
r to
GERAN
EutranIn CellIndi ADD LBFD-0 Coverag Meaning: Indicates the cell individual offset for the
traFreq vidualOf EUTRA 0201801 e Based intra-frequency neighboring cell, which is used in
NCell fset NINTR / Intra- evaluation for handovers. It affects the probability of
AFREQ TDLBF frequenc triggering intra-frequency measurement reports. A
NCELL D-00201 y larger value of this parameter indicates a higher
MOD 801 Handov probability. For details, see 3GPP TS 36.331.
EUTRA TDLBF er GUI Value Range: dB-24(-24dB), dB-22(-22dB),
NINTR D-00201 Mobility dB-20(-20dB), dB-18(-18dB), dB-16(-16dB),
AFREQ 8 Manage dB-14(-14dB), dB-12(-12dB), dB-10(-10dB),
NCELL ment dB-8(-8dB), dB-6(-6dB), dB-5(-5dB), dB-4(-4dB),
LST dB-3(-3dB), dB-2(-2dB), dB-1(-1dB), dB0(0dB),
EUTRA dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB),
NINTR dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB),
AFREQ dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB),
NCELL dB20(20dB), dB22(22dB), dB24(24dB)
Unit: dB
Actual Value Range: dB-24, dB-22, dB-20, dB-18,
dB-16, dB-14, dB-12, dB-10, dB-8, dB-6, dB-5, dB-4,
dB-3, dB-2, dB-1, dB0, dB1, dB2, dB3, dB4, dB5,
dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20,
dB22, dB24
Default Value: dB0(0dB)
IntraFre IntraFre ADD LBFD-0 Coverag Meaning: Indicates the hysteresis for intra-frequency
qHoGro qHoA3 INTRA 0201801 e Based handover event A3. This parameter decreases frequent
up Hyst FREQH / Intra- event triggering due to radio signal fluctuations and
OGROU TDLBF frequenc reduces the probability of handover decision errors
P D-00201 y and ping-pong handovers. A larger value of this
MOD 801 Handov parameter results in a lower probability. The
INTRA er hysteresis for event inter-frequency handover event
FREQH A3 is the same as the value of this parameter. For
OGROU details, see 3GPP TS 36.331.
P GUI Value Range: 0~30
LST Unit: 0.5dB
INTRA Actual Value Range: 0~15
FREQH
OGROU Default Value: 2
P
IntraFre IntraFre ADD LBFD-0 Coverag Meaning: Indicates the offset for event A3. If the
qHoGro qHoA3 INTRA 0201801 e Based parameter is set to a large value, an intra-frequency
up Offset FREQH / Intra- handover is performed only when the signal quality of
OGROU TDLBF frequenc the neighboring cell is significantly better than that of
P D-00201 y the serving cell and other triggering conditions are
MOD 801 Handov met. For details, see 3GPP TS 36.331.
INTRA er GUI Value Range: -30~30
FREQH Unit: 0.5dB
OGROU
P Actual Value Range: -15~15
IntraRat IntraRat MOD LBFD-0 Coverag Meaning: Indicates the maximum number of cells to
HoCom HoMax INTRA 0201801 e Based be included in the measurement report after an intra-
m RprtCell RATHO / Intra- RAT inter-frequency or intra-RAT intra-frequency
COMM TDLBF frequenc measurement event for handover purposes or a
LST D-00201 y periodic intra-RAT measurement for ANR purposes is
INTRA 801 Handov triggered. For details, see 3GPP TS 36.331.
RATHO LBFD-0 er GUI Value Range: 1~8
COMM 0201802 Coverag Unit: None
/ e Based
Inter- Actual Value Range: 1~8
TDLBF
D-00201 frequenc Default Value: 4
802 y
Handov
LBFD-0
er
0201804
/ Distance
TDLBF Based
D-00201 Inter-
804 frequenc
y
LBFD-0
Handov
0201805
er
/
TDLBF Service
D-00201 Based
805 Inter-
frequenc
TDLBF y
D-00201 Handov
8 er
TDLBF Mobility
D-00102 Manage
2 ment
TDLBF SRVCC
D-00102 to
3 UTRAN
TDLBF SRVCC
D-00103 to
3 GERAN
TDLBF CS
D-00103 Fallback
4 to
TDLBF UTRAN
D-00103 CS
5 Fallback
TDLBF to
D-00101 GERAN
9
CS
Fallback
to
CDMA2
000
1xRTT
PS Inter-
RAT
Mobility
between
E-
UTRAN
and
UTRAN
CS
Fallback
to
CDMA2
000
1xRTT
PS Inter-
RAT
Mobility
between
E-
UTRAN
and
UTRAN
Cell DlEarfc ADD LBFD-0 Broadca Meaning: Indicates the DL EARFCN of the cell. For
n CELL 02009 / st of details about this parameter, see 3GPP TS 36.104. For
MOD TDLBF system the detailed usage of 255144 to 262143, see the
CELL D-00200 informat following LTE-U forum document: eNodeB Minimum
9 ion Requirements for LTE-U SDL V1.0.
LST
CELL LBFD-0 Coverag GUI Value Range:
0201801 e Based 0~65535,66436~67335,255144~256143,260894~2621
/ Intra- 43
TDLBF frequenc Unit: None
D-00201 y
801 Actual Value Range:
Handov 0~65535,66436~67335,255144~256143,260894~2621
LBFD-0 er 43
0201803 Cell
/ Default Value: None
Selectio
TDLBF n and
D-00201 Re-
803 selection
/ /
LAOFD LAOFD
-111305 -111301:
LAA(Li
censed
CellRes MeasBa MOD LBFD-0 Cell Meaning: Indicates the measurement bandwidth on
el ndWidth CELLR 0201803 Selectio the serving frequency on which the UE camps. It is
ESEL / n and used in intra-frequency measurements for cell
LST TDLBF Re- reselection and those by UEs in RRC_CONNECTED
CELLR D-00201 selection mode. This parameter is optional; if it is not set, the
ESEL 803 Broadca downlink bandwidth of the serving cell is used by
LBFD-0 st of default.
02009 / system GUI Value Range: MBW6(1.4M), MBW15(3M),
TDLBF informat MBW25(5M), MBW50(10M), MBW75(15M),
D-00200 ion MBW100(20M)
9 Unit: MHz
Actual Value Range: MBW6, MBW15, MBW25,
MBW50, MBW75, MBW100
Default Value: MBW6(1.4M)
ServiceReqInterFreqBlindHoSw(ServiceReqInter-
FreqBlindHoSw), HOSuccRateBoostOptS-
witch(HOSuccRateBoostOptSwitch)
Unit: None
Actual Value Range:
ReduceInvalidA1A2RptSigSwitch,
MultiQciHoExecOptSwitch, ReduceInvalidFreqPri-
HoSwitch, AddA2MeasIfQciAdjSwitch,
InterFreqHoA2OptSwitch, McUtranNcellNumOptSw-
tich, ReduceMeasCtrlMesNumSwitch,
ServiceReqInterFreqBlindHoSw,
HOSuccRateBoostOptSwitch
Default Value: ReduceInvalidA1A2RptSigSwitch:Off,
MultiQciHoExecOptSwitch:Off, ReduceInvalidFreq-
PriHoSwitch:Off, AddA2MeasIfQciAdjSwitch:On,
InterFreqHoA2OptSwitch:Off,
McUtranNcellNumOptSwtich:Off,
ReduceMeasCtrlMesNumSwitch:Off,
ServiceReqInterFreqBlindHoSw:Off,
HOSuccRateBoostOptSwitch:Off
IntraRat InterFre MOD LBFD-0 Coverag Meaning: Indicates whether RSRP or RSRQ is
HoCom qHoA1 INTRA 0201802 e Based measured for events A1 and A2 that are used for inter-
m A2Trig RATHO / Inter- frequency handovers based on event A4 or A5. RSRP
Quan COMM TDLBF frequenc measurements slightly vary with the load, and there is
LST D-00201 y little signal fluctuation. By contrast, RSRQ
INTRA 802 Handov measurements vary with the load and are likely to
RATHO er reflect the signal quality of the cell in real time. For
COMM details, see 3GPP TS 36.331.
GUI Value Range: RSRP, RSRQ, BOTH
Unit: None
Actual Value Range: RSRP, RSRQ, BOTH
Default Value: RSRP
InterFre InterFre ADD LBFD-0 Coverag Meaning: Indicates the hysteresis of events A1/A2 for
qHoGro qHoA1 INTERF 0201802 e Based triggering inter-frequency measurement. This
up A2Hyst REQHO / Inter- parameter is used to prevent frequent triggering of
GROUP TDLBF frequenc event evaluation caused by radio signal fluctuation. In
MOD D-00201 y this way, the probability of ping-pong handovers or
INTERF 802 Handov handover decision errors is reduced. A larger value of
REQHO er this parameter results in a lower probability.
GROUP GUI Value Range: 0~30
LST Unit: 0.5dB
INTERF
Actual Value Range: 0~15
REQHO
GROUP Default Value: 2
InterFre A3Inter ADD LBFD-0 Coverag Meaning: Indicates the RSRP threshold for event A2
qHoGro FreqHo INTERF 0201802 e Based of A3 based inter-frequency handover. When the
up A2ThdR REQHO / Inter- measured RSRP value exceeds this threshold, a
srp GROUP TDLBF frequenc measurement report will be sent.
MOD D-00201 y GUI Value Range: -140~-43
INTERF 802 Handov
er Unit: dBm
REQHO
GROUP Actual Value Range: -140~-43
InterFre A3Inter ADD LBFD-0 Coverag Meaning: Indicates the RSRQ threshold for event A2
qHoGro FreqHo INTERF 0201802 e Based of A3 based inter-frequency handover.
up A2ThdR REQHO / Inter- GUI Value Range: -40~-6
srq GROUP TDLBF frequenc
D-00201 y Unit: 0.5dB
MOD
INTERF 802 Handov Actual Value Range: -20~-3
REQHO er Default Value: -24
GROUP
LST
INTERF
REQHO
GROUP
IntraRat A3Inter MOD LBFD-0 Coverag Meaning: Indicates the trigger quantity for events
HoCom FreqHo INTRA 0201802 e Based A1/A2 of A3 based inter-frequency handover. The
m A1A2Tr RATHO / Inter- quantity can be either RSRP or RSRQ. The measured
igQuan COMM TDLBF frequenc RSRP values are stable, varying little with the load,
LST D-00201 y and therefore there is little signal fluctuation. The
INTRA 802 Handov measured RSRQ values fluctuate greatly with the load
RATHO er and therefore reflect the signal quality of the cell in
COMM real time. For details, see 3GPP TS 36.331.
GUI Value Range: RSRP, RSRQ, BOTH
Unit: None
Actual Value Range: RSRP, RSRQ, BOTH
Default Value: RSRP
InterFre A3Inter ADD LBFD-0 Coverag Meaning: Indicates the RSRP threshold for event A1
qHoGro FreqHo INTERF 0201802 e Based of A3 based inter-frequency handover. When the
up A1ThdR REQHO / Inter- measured RSRP value exceeds this threshold, a
srp GROUP TDLBF frequenc measurement report will be sent.
MOD D-00201 y GUI Value Range: -140~-43
INTERF 802 Handov
er Unit: dBm
REQHO
GROUP Actual Value Range: -140~-43
InterFre A3Inter ADD LBFD-0 Coverag Meaning: Indicates the RSRQ threshold for event A1
qHoGro FreqHo INTERF 0201802 e Based of A3 based inter-frequency handover.
up A1ThdR REQHO / Inter- GUI Value Range: -40~-6
srq GROUP TDLBF frequenc
D-00201 y Unit: 0.5dB
MOD
INTERF 802 Handov Actual Value Range: -20~-3
REQHO er Default Value: -20
GROUP
LST
INTERF
REQHO
GROUP
InterFre InterFre ADD LBFD-0 Coverag Meaning: Indicates the RSRP threshold for event A1
qHoGro qHoA1T INTERF 0201802 e Based of A4/A5 based inter-frequency handover.When the
up hdRsrp REQHO / Inter- measured RSRP value exceeds this threshold, a
GROUP TDLBF frequenc measurement report will be sent.
MOD D-00201 y GUI Value Range: -140~-43
INTERF 802 Handov
er Unit: dBm
REQHO
GROUP Actual Value Range: -140~-43
EutranIn DlEarfc ADD LBFD-0 Coverag Meaning: Indicates the DL EARFCN of the
terNFre n EUTRA 0201802 e Based neighboring cell on the neighboring E-UTRAN
q NINTE / Inter- frequency. For details, see the 3GPP TS 36.104.
RNFRE TDLBF frequenc GUI Value Range:
Q D-00201 y 0~46589,54436~65535,66436~67335
LST 802 Handov
er Unit: None
EUTRA LBFD-0
NINTE 0201803 Cell Actual Value Range:
RNFRE / Selectio 0~46589,54436~65535,66436~67335
Q TDLBF n and Default Value: None
MOD D-00201 Re-
EUTRA 803 selection
NINTE LBFD-0 Distance
RNFRE 0201804 Based
Q / Inter-
RMV TDLBF frequenc
EUTRA D-00201 y
NINTE 804 Handov
RNFRE LBFD-0 er
Q 0201805 Service
/ Based
TDLBF Inter-
D-00201 frequenc
805 y
TDLOF Handov
D-00105 er
0 Mobility
between
LTE
TDD
and LTE
FDD
EutranIn QoffsetF ADD LBFD-0 Coverag Meaning: Indicates the frequency-specific offset for
terNFre reqConn EUTRA 0201802 e Based the neighboring E-UTRAN frequency that applies to
q NINTE / Inter- UEs in connected mode. It is contained in the event
RNFRE TDLBF frequenc A3/A4/A5 measurement configuration and delivered
Q D-00201 y to UEs in connected mode. The offset affects the
MOD 802 Handov probability of reporting events A3, A4, and A5. For
EUTRA LBFD-0 er details, see 3GPP TS 36.331.
NINTE 0201804 Distance GUI Value Range: dB-24(-24dB), dB-22(-22dB),
RNFRE / Based dB-20(-20dB), dB-18(-18dB), dB-16(-16dB),
Q TDLBF Inter- dB-14(-14dB), dB-12(-12dB), dB-10(-10dB),
LST D-00201 frequenc dB-8(-8dB), dB-6(-6dB), dB-5(-5dB), dB-4(-4dB),
EUTRA 804 y dB-3(-3dB), dB-2(-2dB), dB-1(-1dB), dB0(0dB),
NINTE LBFD-0 Handov dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB),
RNFRE 0201805 er dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB),
Q / Service dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB),
TDLBF Based dB20(20dB), dB22(22dB), dB24(24dB)
D-00201 Inter- Unit: dB
805 frequenc Actual Value Range: dB-24, dB-22, dB-20, dB-18,
y dB-16, dB-14, dB-12, dB-10, dB-8, dB-6, dB-5, dB-4,
Handov dB-3, dB-2, dB-1, dB0, dB1, dB2, dB3, dB4, dB5,
er dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20,
dB22, dB24
Default Value: dB0(0dB)
EutranIn MeasBa ADD LBFD-0 Coverag Meaning: Indicates the measurement bandwidth of the
terNFre ndWidth EUTRA 0201802 e Based inter-frequency neighboring cell on the frequency. The
q NINTE / Inter- setting of this parameter depends on the bandwidth
RNFRE TDLBF frequenc configuration of the cell. In E-UTRAN, a cell
Q D-00201 y bandwidth is also expressed in units of resource
MOD 802 Handov blocks (RBs). Cell bandwidths 1.4 MHz, 3 MHz, 5
EUTRA LBFD-0 er MHz, 10 MHz, 15 MHz, and 20 MHz correspond to 6
NINTE 0201804 Distance RBs, 15 RBs, 25 RBs, 50 RBs, 75 RBs, and 100 RBs,
RNFRE / Based respectively.
Q TDLBF Inter- GUI Value Range: MBW6(1.4M), MBW15(3M),
LST D-00201 frequenc MBW25(5M), MBW50(10M), MBW75(15M),
EUTRA 804 y MBW100(20M)
NINTE LBFD-0 Handov Unit: None
RNFRE 0201805 er
Actual Value Range: MBW6, MBW15, MBW25,
Q / Service MBW50, MBW75, MBW100
TDLBF Based
D-00201 Inter- Default Value: None
805 frequenc
y
Handov
er
EutranIn CellIndi ADD LBFD-0 Coverag Meaning: Indicates the cell individual offset for the
terFreq vidualOf EUTRA 0201802 e Based inter-frequency neighboring cell, which is used in
NCell fset NINTE / Inter- evaluation for handovers. It affects the probability of
RFREQ TDLBF frequenc triggering inter-frequency measurement reports. A
NCELL D-00201 y larger value of this parameter indicates a higher
MOD 802 Distance probability. For details, see 3GPP TS 36.331.
EUTRA LBFD-0 Based GUI Value Range: dB-24(-24dB), dB-22(-22dB),
NINTE 0201804 Inter- dB-20(-20dB), dB-18(-18dB), dB-16(-16dB),
RFREQ / frequenc dB-14(-14dB), dB-12(-12dB), dB-10(-10dB),
NCELL TDLBF y dB-8(-8dB), dB-6(-6dB), dB-5(-5dB), dB-4(-4dB),
LST D-00201 Handov dB-3(-3dB), dB-2(-2dB), dB-1(-1dB), dB0(0dB),
EUTRA 804 er dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB),
NINTE LBFD-0 Service dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB),
RFREQ 0201805 Based dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB),
NCELL / Inter- dB20(20dB), dB22(22dB), dB24(24dB)
TDLBF frequenc Unit: dB
D-00201 y Actual Value Range: dB-24, dB-22, dB-20, dB-18,
805 Handov dB-16, dB-14, dB-12, dB-10, dB-8, dB-6, dB-5, dB-4,
er dB-3, dB-2, dB-1, dB0, dB1, dB2, dB3, dB4, dB5,
dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20,
dB22, dB24
Default Value: dB0(0dB)
TDLOF Handov
D-00104 er
3 SRVCC
TDLOF to
D-00107 UTRAN
2 SRVCC
TDLOF to
D-00104 GERAN
6 CS
TDLOF Fallback
D-00107 to
3 UTRAN
CS
Fallback
to
GERAN
CS
Fallback
to
CDMA2
000
1xRTT
Service
based
Inter-
RAT
handove
r to
UTRAN
Distance
based
Inter-
RAT
handove
r to
UTRAN
Service
based
Inter-
RAT
handove
r to
GERAN
Distance
based
Inter-
RAT
handove
r to
GERAN
INTER_RAT_MLB_LOW_PRIO_IND(INTER_RAT
_MLB_LOW_PRIO_IND),
HO_USE_VOIP_FREQ_ALLOWED(HO_USE_VOI
P_FREQ_ALLOWED)
Unit: None
Actual Value Range:
INTER_FREQ_MLB_ALLOWED,
INTER_FREQ_MLB_LOW_PRIO_IND,
INTER_RAT_MLB_ALLOWED,
INTER_RAT_MLB_LOW_PRIO_IND,
HO_USE_VOIP_FREQ_ALLOWED
Default Value: INTER_FREQ_MLB_ALLOWED:On,
INTER_FREQ_MLB_LOW_PRIO_IND:Off,
INTER_RAT_MLB_ALLOWED:On,
INTER_RAT_MLB_LOW_PRIO_IND:Off,
HO_USE_VOIP_FREQ_ALLOWED:Off
CellAlg MultiFre MOD LBFD-0 Coverag Meaning: Indicates whether to prioritize frequencies
oSwitch qPriCon CELLA 0201802 e Based in a multi-frequency network.
trolSwit LGOSW / Inter- FixedMeasObjIDSwitch: Indicates whether the
ch ITCH TDLBF frequenc eNodeB maps each neighboring frequency to a
LST D-00201 y MeasObjectID based on the frequency measurement
CELLA 802 Handov priorities. If this switch is on, the eNodeB maps each
LGOSW LBFD-0 er neighboring frequency to a corresponding
ITCH 0201804 Distance MeasObjectID based on the frequency measurement
/ Based priorities. A higher-priority frequency is mapped to a
TDLBF Inter- smaller MeasObjectID. If this switch is off, the
D-00201 frequenc eNodeB does not map neighboring frequencies to
804 y MeasObjectIDs based on the frequency measurement
Handov priorities. VoipMeasFreqPriSwitch: Indicates whether
LBFD-0 the frequency priority specified by the VoipPriority
0201805 er
parameter takes effect during coverage-based
/ Service handovers for VoIP UEs. If this switch is on, the
TDLBF Based eNodeB only delivers the highest-priority intra-RAT
D-00201 Inter- frequencies different from the serving frequency based
805 frequenc on the settings of the VoipPriority parameter when the
y eNodeB delivers the measurement configurations to
Handov VoIP UEs for coverage-based inter-frequency
er handovers. If this switch is off, the eNodeB does not
consider the settings of the VoipPriority parameter
when delivering the measurement configurations to
VoIP UEs for coverage-based inter-frequency
handovers.
GUI Value Range:
FixedMeasObjIDSwitch(FixedMeasObjIDSwitch),
VoipMeasFreqPriSwitch(VoipMeasFreqPriSwitch),
PsMeasFreqPriSwitch(PsMeasFreqPriSwitch)
Unit: None
Actual Value Range: FixedMeasObjIDSwitch,
VoipMeasFreqPriSwitch, PsMeasFreqPriSwitch
Default Value: FixedMeasObjIDSwitch:Off,
VoipMeasFreqPriSwitch:Off,
PsMeasFreqPriSwitch:Off
EutranIn ConnFre ADD LBFD-0 Coverag Meaning: Indicates the frequency priority based on
terNFre qPriority EUTRA 0201802 e Based which the eNodeB selects a target frequency for blind
q NINTE / Inter- redirection or contains a frequency in a measurement
RNFRE TDLBF frequenc configuration. If a blind redirection is triggered and
Q D-00201 y the target neighboring cell is not specified, the
MOD 802 Handov eNodeB selects a target frequency based on this
EUTRA LBFD-0 er priority. If a measurement configuration is to be
NINTE 0201804 Distance delivered, the eNodeB preferentially delivers a
RNFRE / Based frequency with the highest priority. If this priority is
Q TDLBF Inter- set to 0 for a frequency, this frequency is not selected
D-00201 frequenc as the target frequency for a blind redirection. A larger
LST value indicates a higher priority.
EUTRA 804 y
NINTE Handov GUI Value Range: 0~16
RNFRE er Unit: None
Q Actual Value Range: 0~16
Default Value: 0
EutranIn MeasFre ADD LBFD-0 Coverag Meaning: Indicates the frequency measurement
terNFre qPriority EUTRA 0201802 e Based priority. A larger value indicates a higher priority.
q NINTE / Inter- GUI Value Range: 0~16
RNFRE TDLBF frequenc
Q D-00201 y Unit: None
EutranIn CellMea ADD LBFD-0 Coverag Meaning: Indicates the priority of measurement on the
terFreq sPriority EUTRA 0201802 e Based inter-frequency neighboring cell. The eNodeB
NCell NINTE / Inter- preferentially contains the information about a
RFREQ TDLBF frequenc neighboring cell with this priority set to
NCELL D-00201 y HIGH_PRIORITY while delivering a measurement
MOD 802 Handov configuration.
EUTRA LBFD-0 er GUI Value Range: LOW_PRIORITY(Low Priority),
NINTE 0201804 Distance HIGH_PRIORITY(High Priority)
RFREQ / Based Unit: None
NCELL TDLBF Inter-
D-00201 frequenc Actual Value Range: LOW_PRIORITY,
LST HIGH_PRIORITY
EUTRA 804 y
NINTE LBFD-0 Handov Default Value: LOW_PRIORITY(Low Priority)
RFREQ 0201805 er
NCELL / Service
TDLBF Based
D-00201 Inter-
805 frequenc
TDLOF y
D-00105 Handov
0 er
Mobility
between
LTE
TDD
and LTE
FDD
EutranIn InterFre ADD LOFD-0 Intra- Meaning: Indicates the event to trigger coverage-
terNFre qHoEve EUTRA 01032 / LTE based inter-frequency handovers. This parameter can
q ntType NINTE TDLOF Load be set to EventA3, EventA4, or EventA5. If the
RNFRE D-00103 Balancin neighboring E-UTRAN frequency and the serving
Q 2 g frequency are in the same frequency band, event A3 is
MOD LOFD-0 Intra- recommended as it provides better handover
EUTRA 70215 / LTE performance in this situation. If the neighboring E-
NINTE TDLOF User UTRAN frequency and the serving frequency are in
RNFRE D-07021 Number different frequency bands, event A4 or A5 is used.
Q 5 Load GUI Value Range: EventA3(EventA3),
LST LOFD-0 Balancin EventA4(EventA4), EventA5(EventA5)
EUTRA 70204 g Unit: None
NINTE Operator Actual Value Range: EventA3, EventA4, EventA5
RNFRE Load
Q Based Default Value: EventA4(EventA4)
Intra-
LTE
MLB
IntraRat InterFre MOD LBFD-0 Coverag Meaning: Indicates the quantity to be included in the
HoCom qHoA4 INTRA 0201802 e Based measurement report for inter-frequency handover
m RprtQua RATHO / Inter- events. The quantity can be RSRP, RSRQ, or both.
n COMM TDLBF frequenc The measured RSRP values are stable, slightly
LST D-00201 y varying with the load, and therefore there is little
INTRA 802 Handov signal fluctuation. The measured RSRQ values vary
RATHO LBFD-0 er with the load and are likely to reflect the signal quality
COMM 0201804 Distance of the cell in real time. This parameter applies to
/ Based measurements for event A4/A5. For details, see 3GPP
TDLBF Inter- TS 36.331.
D-00201 frequenc GUI Value Range: SAME_AS_TRIG_QUAN(Same
804 y as Trig Quan), BOTH
LBFD-0 Handov Unit: None
0201805 er
Actual Value Range: SAME_AS_TRIG_QUAN,
/ Service BOTH
TDLBF Based
D-00201 Inter- Default Value: SAME_AS_TRIG_QUAN(Same as
805 frequenc Trig Quan)
y
Handov
er
InterFre InterFre ADD LBFD-0 Coverag Meaning: Indicates the offset for event A3 associated
qHoGro qHoA3 INTERF 0201802 e Based with inter-frequency handover. This parameter
up Offset REQHO / Inter- determines the border between the serving cell and the
GROUP TDLBF frequenc neighboring cell. If the parameter is set to a large
MOD D-00201 y value, an inter-frequency handover is performed only
INTERF 802 Handov when the signal quality of the neighboring cell is
REQHO er significantly better than that of the serving cell and
GROUP other triggering conditions are met. For details, see
3GPP TS 36.331.
LST
INTERF GUI Value Range: -30~30
REQHO Unit: 0.5dB
GROUP Actual Value Range: -15~15
Default Value: 2
InterFre InterFre ADD LBFD-0 Coverag Meaning: Indicates the hysteresis for event A4. This
qHoGro qHoA4 INTERF 0201802 e Based parameter is used to prevent frequent triggering of
up Hyst REQHO / Inter- event evaluation caused by radio signal fluctuation. In
GROUP TDLBF frequenc this way, the probability of ping-pong handovers or
MOD D-00201 y handover decision errors is reduced. A larger value of
INTERF 802 Handov this parameter results in a lower probability.
REQHO LBFD-0 er GUI Value Range: 0~30
GROUP 0201804 Distance Unit: 0.5dB
LST / Based
TDLBF Inter- Actual Value Range: 0~15
INTERF
REQHO D-00201 frequenc Default Value: 2
GROUP 804 y
LBFD-0 Handov
0201805 er
/ Service
TDLBF Based
D-00201 Inter-
805 frequenc
y
Handov
er
InterFre InterFre ADD LBFD-0 Coverag Meaning: Indicates the RSRP threshold for event A4
qHoGro qHoA4T INTERF 0201802 e Based related to coverage-based inter-frequency handover.
up hdRsrp REQHO / Inter- When the measured RSRP value exceeds this
GROUP TDLBF frequenc threshold, event A4 is reported. The value of this
MOD D-00201 y parameter is also used as the RSRP threshold for event
INTERF 802 Handov A4 related to distance-based, UL-power-based, or
REQHO LBFD-0 er SPID-based inter-frequency handover back to the
GROUP 0201804 Distance HPLMN.
LST / Based GUI Value Range: -140~-43
INTERF TDLBF Inter- Unit: dBm
REQHO D-00201 frequenc
804 y Actual Value Range: -140~-43
GROUP
Handov Default Value: -105
er
EutranIn IfHoThd ADD LBFD-0 Coverag Meaning: Indicates the offset to the RSRP threshold
terNFre RsrpOff EUTRA 0201802 e Based for events A4 and A5 that trigger coverage-based
q set NINTE / Inter- inter-frequency handovers. In coverage-based
RNFRE TDLBF frequenc handovers, the eNodeB delivers the RSRP threshold
Q D-00201 y for event A4 or A5 to UEs, which is equal to the sum
MOD 802 Handov of the InterFreqHoA4ThdRsrp and
EUTRA er IfHoThdRsrpOffset parameter values. If the RSRP
NINTE threshold for event A4 or A5 is less than the minimum
RNFRE RSRP value, the minimum value is delivered instead.
Q If the RSRP threshold for event A4 or A5 is greater
than the maximum RSRP value, the maximum value
LST is delivered instead.
EUTRA
NINTE GUI Value Range: -20~20
RNFRE Unit: dBm
Q Actual Value Range: -20~20
Default Value: 0
InterFre InterFre ADD LBFD-0 Coverag Meaning: Indicates the RSRQ threshold for event A4
qHoGro qHoA4T INTERF 0201802 e Based related to coverage-based inter-frequency handover.
up hdRsrq REQHO / Inter- When the measured RSRQ value exceeds this
GROUP TDLBF frequenc threshold, event A4 is reported. The value of this
MOD D-00201 y parameter is also used as the RSRQ threshold for
INTERF 802 Handov event A4 related to distance-based, UL-power-based,
REQHO LBFD-0 er or SPID-based inter-frequency handover back to the
GROUP 0201804 Distance HPLMN.
LST / Based GUI Value Range: -40~-6
INTERF TDLBF Inter- Unit: 0.5dB
REQHO D-00201 frequenc
804 y Actual Value Range: -20~-3
GROUP
Handov Default Value: -20
er
InterRat InterRat MOD LOFD-0 PS Inter- Meaning: Indicates the trigger quantity for event
HoCom HoA1A INTER 01019 / RAT A1/A2 of inter-RAT measurement. The quantity can
m 2TrigQu RATHO TDLOF Mobility be RSRP, RSRQ, or both RSRP and RSRQ. The
an COMM D-00101 between measured RSRP values are stable, varying little with
LST 9 E- the load, and therefore there is little signal fluctuation.
INTER LOFD-0 UTRAN The measured RSRQ values vary with the load and
RATHO 01020 / and are likely to reflect the signal quality of the cell in real
COMM TDLOF UTRAN time. For details, see 3GPP TS 36.331.
D-00102 PS Inter- GUI Value Range: RSRP, RSRQ, BOTH
0 RAT Unit: None
LOFD-0 Mobility
between Actual Value Range: RSRP, RSRQ, BOTH
01021 /
TDLOF E- Default Value: RSRP
D-00102 UTRAN
1 and
GERAN
TDLOF
D-00102 PS Inter-
2 RAT
Mobility
TDLOF between
D-00102 E-
3 UTRAN
and
CDMA2
000
SRVCC
to
UTRAN
SRVCC
to
GERAN
InterRat InterRat ADD LOFD-0 PS Inter- Meaning: Indicates the hysteresis of events A1/A2 for
HoCom HoA1A INTER 01019 / RAT triggering inter-RAT measurement. This parameter is
mGroup 2Hyst RATHO TDLOF Mobility used to prevent frequent triggering of event evaluation
COMM D-00101 between caused by radio signal fluctuation. In this way, the
GROUP 9 E- probability of ping-pong handovers or handover
MOD LOFD-0 UTRAN decision errors is reduced. A larger value of this
INTER 01020 / and parameter results in a lower probability.
RATHO TDLOF UTRAN GUI Value Range: 0~30
COMM D-00102 PS Inter- Unit: 0.5dB
GROUP 0 RAT
Mobility Actual Value Range: 0~15
LST LOFD-0
INTER 01021 / between Default Value: 2
RATHO TDLOF E-
COMM D-00102 UTRAN
GROUP 1 and
GERAN
TDLOF
D-00102 PS Inter-
2 RAT
Mobility
TDLOF between
D-00102 E-
3 UTRAN
and
CDMA2
000
SRVCC
to
UTRAN
SRVCC
to
GERAN
CellHoP BlindHo MOD LBFD-0 Coverag Meaning: Indicates the RSRP threshold for events
araCfg A1A2Th CELLH 0201802 e Based A1/A2 that are used for coverage based inter-
dRsrp OPARA / Inter- frequency blind handover and coverage based inter-
CFG TDLBF frequenc RAT blind handover. If the RSRP measurement result
LST D-00201 y of the serving cell is higher than the sum of this
CELLH 802 Handov threshold and the hysteresis throughout the time-to-
OPARA LOFD-0 er trigger, event A1 is reported. If the RSRP
CFG 01019 / PS Inter- measurement result of the serving cell is lower than
TDLOF RAT this threshold minus the hysteresis throughout the
D-00101 Mobility time-to-trigger, event A2 is reported.
9 between GUI Value Range: -140~-43
LOFD-0 E- Unit: dBm
01020 / UTRAN
and Actual Value Range: -140~-43
TDLOF
D-00102 UTRAN Default Value: -121
0 PS Inter-
LOFD-0 RAT
01021 / Mobility
TDLOF between
D-00102 E-
1 UTRAN
and
GERAN
PS Inter-
RAT
Mobility
between
E-
UTRAN
and
CDMA2
000
CellHoP BlindHo MOD LBFD-0 Coverag Meaning: Indicates the RSRQ threshold for events
araCfg A1A2Th CELLH 0201802 e Based A1/A2 that are used for coverage based inter-
dRsrq OPARA / Inter- frequency blind handover and coverage based inter-
CFG TDLBF frequenc RAT blind handover. If the RSRQ measurement result
LST D-00201 y of the serving cell is higher than the sum of this
CELLH 802 Handov threshold and the hysteresis throughout the time-to-
OPARA LOFD-0 er trigger, event A1 is reported. If the RSRQ
CFG 01019 / PS Inter- measurement result of the serving cell is lower than
TDLOF RAT this threshold minus the hysteresis throughput the
D-00101 Mobility time-to-trigger, event A2 is reported.
9 between GUI Value Range: -40~-6
LOFD-0 E- Unit: 0.5dB
01020 / UTRAN
and Actual Value Range: -20~-3
TDLOF
D-00102 UTRAN Default Value: -28
0 PS Inter-
LOFD-0 RAT
01021 / Mobility
TDLOF between
D-00102 E-
1 UTRAN
and
GERAN
PS Inter-
RAT
Mobility
between
E-
UTRAN
and
CDMA2
000
EutranIn BlindHo ADD LBFD-0 Coverag Meaning: Indicates the priority of the neighboring cell
terFreq Priority EUTRA 0201802 e Based during handovers. The parameter values are divided
NCell NINTE / Inter- into three segments, indicating the blind-handover
RFREQ TDLBF frequenc priority, frequency-based-handover priority, and 0.
NCELL D-00201 y Within the same segment, a larger parameter value
MOD 802 Handov indicates a higher priority. Blind handover is a process
EUTRA LBFD-0 er in which the eNodeB instructs a UE to hand over to a
NINTE 0201804 Distance specified neighboring cell without measurements. If
RFREQ / Based this parameter value is set to 0, blind handovers and
NCELL TDLBF Inter- frequency-based handovers cannot be performed. The
D-00201 frequenc parameter values 1 to 16 indicate the blind-handover
LST priorities. The parameter values 17 to 32 indicate the
EUTRA 804 y
Handov frequency-based-handover priorities for frequency-
NINTE TDLOF based blind handovers and measurement-based
RFREQ D-00105 er
handovers.
NCELL 0 Mobility
between GUI Value Range: 0~32
LTE Unit: None
TDD
Actual Value Range: 0~32
and LTE
FDD Default Value: 0
CnOper FirstRat MOD LBFD-0 Coverag Meaning: Indicates the priority of E-UTRAN TDD or
atorHoC Pri CNOPE 0201802 e Based E-UTRAN FDD in inter-frequency blind handover or
fg RATOR / Inter- blind redirection scenarios. To prioritize E-UTRAN
HOCFG TDLBF frequenc TDD or E-UTRAN FDD, set this parameter to
LST D-00201 y EUTRAN_TDD or EUTRAN_FDD, respectively. To
CNOPE 802 treat E-UTRAN TDD and E-UTRAN FDD equally,
RATOR set this parameter to EUTRAN.
HOCFG GUI Value Range: EUTRAN_TDD, EUTRAN_FDD,
EUTRAN
Unit: None
Actual Value Range: EUTRAN_TDD,
EUTRAN_FDD, EUTRAN
Default Value: EUTRAN
CnOper Second MOD LBFD-0 Coverag Meaning: Indicates the priority of E-UTRAN TDD or
atorHoC RatPri CNOPE 0201802 e Based E-UTRAN FDD in inter-frequency blind handover or
fg RATOR / Inter- blind redirection scenarios. To prioritize E-UTRAN
HOCFG TDLBF frequenc TDD or E-UTRAN FDD, set this parameter to
LST D-00201 y EUTRAN_TDD or EUTRAN_FDD, respectively. If
CNOPE 802 the FirstRatPri parameter is set to EUTRAN, the
RATOR SecondRatPri parameter must be set to NULL,
HOCFG indicating that E-UTRAN TDD and E-UTRAN FDD
are not prioritized.
GUI Value Range: EUTRAN_TDD, EUTRAN_FDD,
NULL
Unit: None
Actual Value Range: EUTRAN_TDD,
EUTRAN_FDD, NULL
Default Value: NULL
CellOp FirstRat ADD LBFD-0 Coverag Meaning: Indicates the priority for E-UTRAN TDD or
HoCfg Pri CELLO 0201802 e Based E-UTRAN FDD in blind handovers. If this parameter
PHOCF / Inter- is set to EUTRAN, E-UTRAN FDD and E-UTRAN
G TDLBF frequenc TDD are not prioritized. If this parameter is set to
MOD D-00201 y EUTRAN FDD, the priority of E-UTRAN FDD is
CELLO 802 higher than that of E-UTRAN TDD. If this parameter
PHOCF is set to EUTRAN TDD, the priority of E-UTRAN
G TDD is higher than that of E-UTRAN FDD.
LST GUI Value Range: EUTRAN_TDD, EUTRAN_FDD,
CELLO EUTRAN
PHOCF Unit: None
G Actual Value Range: EUTRAN_TDD,
EUTRAN_FDD, EUTRAN
Default Value: EUTRAN
ServiceI InterFre ADD LBFD-0 Service Meaning: Indicates whether to allow service-based
fHoCfg qHoStat SERVIC 0201805 Based inter-frequency handovers of the policy group to a
Group e EIFHO / Inter- specified frequency. If this parameter is set to
CFGGR TDLBF frequenc NO_HO, service-based inter-frequency handovers of
OUP D-00201 y this policy group to a specified frequency are not
MOD 805 Handov allowed. If this parameter is set to PERMIT_HO, such
SERVIC er handovers are allowed.
EIFHO GUI Value Range: NO_HO, PERMIT_HO
CFGGR Unit: None
OUP
Actual Value Range: NO_HO, PERMIT_HO
LST
SERVIC Default Value: NO_HO
EIFHO
CFGGR
OUP
ServiceI DlEarfc ADD LBFD-0 Service Meaning: Indicates a DL EARFCN for service-based
fDlEarfc n SERVIC 0201805 Based inter-frequency handover. Only the value with
nGrp EIFDLE / Inter- DlEarfcnIndex 0 in the DL EARFCN group is valid
ARFCN TDLBF frequenc for LTE FDD cells. All values of this parameter are
GRP D-00201 y valid and have the same priority for LTE TDD cells.
MOD 805 Handov GUI Value Range:
SERVIC TDLOF er 0~46589,54436~65535,66436~67335
EIFDLE D-07022 Service- Unit: None
ARFCN 8 Request
GRP Based Actual Value Range:
Inter- 0~46589,54436~65535,66436~67335
LST
SERVIC frequenc Default Value: 0
EIFDLE y
ARFCN Handov
GRP er
CnOper Qci LST None None Meaning: Indicates the QoS Class Identifier (QCI) of
atorStan CNOPE an EPS bearer. Different QCIs represent different QoS
dardQci RATOR specifications such as the packet delay budget, packet
STAND error loss rate, and resource type (whether the service
ARDQC is a GBR service or not). For details, see Table 6.1.7
I in 3GPP TS 23.203.
MOD GUI Value Range: QCI1(QCI 1), QCI2(QCI 2),
CNOPE QCI3(QCI 3), QCI4(QCI 4), QCI5(QCI 5), QCI6(QCI
RATOR 6), QCI7(QCI 7), QCI8(QCI 8), QCI9(QCI 9)
STAND Unit: None
ARDQC
I Actual Value Range: QCI1, QCI2, QCI3, QCI4, QCI5,
QCI6, QCI7, QCI8, QCI9
Default Value: None
Extende Extende ADD LBFD-0 Extende Meaning: Indicates the extended QoS Class Identifier
dQci dQci EXTEN 02032 d-QCI (QCI), which is required by the operator for user
DEDQC LOFD-0 Dynami differentiation.
I 0101502 c GUI Value Range: 10~254
LST / Scheduli Unit: None
EXTEN TDLOF ng
DEDQC D-00101 Actual Value Range: 10~254
I 502 Default Value: None
MOD
EXTEN
DEDQC
I
RMV
EXTEN
DEDQC
I
ServiceI Service ADD LBFD-0 Service Meaning: Indicates the priority for the frequency as
fDlEarfc HoFreq SERVIC 0201805 Based the target frequency for service-based and service-
nGrp Priority EIFDLE / Inter- request-based inter-frequency handovers. A larger
ARFCN TDLBF frequenc value indicates a higher priority. When evaluating
GRP D-00201 y service-based and service-request-based inter-
MOD 805 Handov frequency handovers, the eNodeB selects the
SERVIC er neighboring E-UTRA frequencies in descending order
EIFDLE by priority.
ARFCN GUI Value Range: 0~15
GRP Unit: None
LST Actual Value Range: 0~15
SERVIC
EIFDLE Default Value: 3
ARFCN
GRP
ENodeB Service MOD None None Meaning: Indicates whether services in a service
AlgoSwi HoMulti ENODE group can be transferred to different E-UTRAN
tch TargetFr BALGO frequencies by service-based handovers. This
eqSw SWITC parameter applies only to LTE FDD. If this parameter
H is set to ON, services in a service group can be
LST transferred to different E-UTRAN frequencies
ENODE specified in the ServiceIfDlEarfcnGrp MO. If this
BALGO parameter is set to OFF, services in a service group
SWITC can be transferred only to the frequency with an index
H of 0.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF(Off)
ServiceI DlEarfc ADD LBFD-0 Service Meaning: Indicates the index of a DL EARFCN in a
fDlEarfc nIndex SERVIC 0201805 Based DL EARFCN group for service-based inter-frequency
nGrp EIFDLE / Inter- handover.
ARFCN TDLBF frequenc GUI Value Range: 0~15
GRP D-00201 y
805 Handov Unit: None
LST
SERVIC TDLOF er Actual Value Range: 0~15
EIFDLE D-07022 Service- Default Value: None
ARFCN 8 Request
GRP Based
MOD Inter-
SERVIC frequenc
EIFDLE y
ARFCN Handov
GRP er
RMV
SERVIC
EIFDLE
ARFCN
GRP
ServiceI A4Rpt ADD TDLBF Service Meaning: Indicates the service-based inter-frequency
fHoCfg Waiting SERVIC D-00201 Based A4 measurement report waiting timer. If the inter-
Group Timer EIFHO 805 Inter- frequency measurement is triggered due to service- or
CFGGR TDLOF frequenc service request-based inter-frequency handover, the
OUP D-07022 y time for a UE performing inter-frequency
MOD 8 Handov measurement must be restricted. This prevents the UE
SERVIC er from performing repeated GAP measurements when it
EIFHO Service- does not receive measurement reports in a period,
CFGGR Request ensuring that data transmission will not be affected.
OUP Based This parameter is dedicated to LTE TDD cells.
LST Inter- GUI Value Range: 10~20000
SERVIC frequenc
Unit: ms
EIFHO y
Handov Actual Value Range: 10~20000
CFGGR
OUP er Default Value: 3000
InterFre InterFre ADD LBFD-0 Service Meaning: Indicates the RSRP threshold for event A4
qHoGro qLoadB INTERF 0201805 Based related to load-based inter-frequency handovers.
up asedHo REQHO / Inter- When the measured RSRP value exceeds this
A4ThdR GROUP TDLBF frequenc threshold, event A4 is reported. This parameter also
srp MOD D-00201 y specifies the RSRP threshold for inter-frequency event
INTERF 805 Handov A4 related to frequency-priority-based handovers,
REQHO er service-based handovers, handovers of low-mobility
GROUP UEs, or redirection of high-mobility UEs.
LST GUI Value Range: -140~-43
INTERF Unit: dBm
REQHO Actual Value Range: -140~-43
GROUP
Default Value: -103
IntraRat InterFre MOD LBFD-0 Coverag Meaning: Indicates the trigger quantity for event
HoCom qHoA4T INTRA 0201802 e Based A4/A5 measurement reports of all inter-frequency
m rigQuan RATHO / Inter- handovers except coverage-based inter-frequency
COMM TDLBF frequenc handover.
LST D-00201 y GUI Value Range: RSRP, RSRQ, BOTH
INTRA 802 Handov
er Unit: None
RATHO LBFD-0
COMM 0201804 Distance Actual Value Range: RSRP, RSRQ, BOTH
/ Based Default Value: RSRP
TDLBF Inter-
D-00201 frequenc
804 y
LBFD-0 Handov
0201805 er
/ Service
TDLBF Based
D-00201 Inter-
805 frequenc
y
Handov
er
InterFre InterFre ADD LBFD-0 Service Meaning: Indicates the RSRQ threshold for event A4
qHoGro qLoadB INTERF 0201805 Based related to load-based inter-frequency handovers.
up asedHo REQHO / Inter- When the measured RSRQ value exceeds this
A4ThdR GROUP TDLBF frequenc threshold, event A4 is reported. This parameter also
srq MOD D-00201 y specifies the RSRQ threshold for inter-frequency
INTERF 805 Handov event A4 related to frequency-priority-based
REQHO er handovers, service-based handovers, handovers of
GROUP low-mobility UEs, or redirection of high-mobility
UEs.
LST
INTERF GUI Value Range: -40~-6
REQHO Unit: 0.5dB
GROUP Actual Value Range: -20~-3
Default Value: -18
CellAlg DistBas MOD LBFD-0 Distance Meaning: Indicates the switch used to enable or
oSwitch edHoSw CELLA 0201804 Based disable distance-based handovers. If this switch is
itch LGOSW / Inter- turned on, distance-based handovers are allowed. If
ITCH TDLBF frequenc this switch is turned off, distance-based handovers are
LST D-00201 y prohibited.
CELLA 804 Handov GUI Value Range: OFF(Off), ON(On)
LGOSW LOFD-0 er
Unit: None
ITCH 01072 / Distance
TDLOF based Actual Value Range: OFF, ON
D-00107 Inter- Default Value: OFF(Off)
2 RAT
LOFD-0 handove
01073 / r to
TDLOF UTRAN
D-00107 Distance
3 based
Inter-
RAT
handove
r to
GERAN
DistBas DistBas MOD LOFD-0 Distance Meaning: Indicates the measurement object type for
edHO edMeas DISTB 01072 / based distance-based handovers. The measurement object
ObjType ASEDH TDLOF Inter- type can be E-UTRAN, UTRAN, or GERAN.
O D-00107 RAT GUI Value Range: EUTRAN, GERAN, UTRAN
LST 2 handove
r to Unit: None
DISTB LOFD-0
ASEDH 01073 / UTRAN Actual Value Range: EUTRAN, GERAN, UTRAN
O TDLOF Distance Default Value: EUTRAN:Off, GERAN:Off,
D-00107 based UTRAN:Off
3 Inter-
LBFD-0 RAT
0201804 handove
/ r to
TDLBF GERAN
D-00201 Distance
804 Based
Inter-
frequenc
y
Handov
er
DistBas DistBas MOD LBFD-0 Distance Meaning: Indicates the threshold for distance-based
edHO edHOTh DISTB 0201804 Based handovers. If the distance between a UE and the cell
d ASEDH / Inter- center is greater than this threshold, a distance-based
O TDLBF frequenc handover is triggered for this UE.
LST D-00201 y GUI Value Range: 1~1000
DISTB 804 Handov
er Unit: 100m
ASEDH LOFD-0
O 01072 / Distance Actual Value Range: 100~100000
TDLOF based Default Value: 10
D-00107 Inter-
2 RAT
LOFD-0 handove
01073 / r to
TDLOF UTRAN
D-00107 Distance
3 based
Inter-
RAT
handove
r to
GERAN
InterFre UlBadQ ADD None None Meaning: Indicates the offset of the A4 threshold of
qHoGro ualHoA INTERF the target cell related to UL-quality-based inter-
up 4Offset REQHO frequency handovers to the A4 threshold related to
GROUP coverage-based inter-frequency handovers. This offset
MOD applies to RSRP- and RSRQ-based A4 thresholds.
INTERF The actual threshold for event A4 is equal to the sum
REQHO of the threshold for event A4 related to coverage-
GROUP based inter-frequency handovers and the
UlBadQualHoA4Offset parameter value. If the sum is
LST less than the 3GPP-defined minimum value or greater
INTERF than the 3GPP-defined maximum value, the 3PGG-
REQHO defined minimum or maximum value is delivered,
GROUP respectively.
GUI Value Range: -20~20
Unit: None
Actual Value Range: -20~20
Default Value: 0
InterFre FreqPriI ADD None None Meaning: Indicates the RSRP threshold for frequency-
qHoGro nterFreq INTERF priority-based inter-frequency measurement event A1.
up HoA1Th REQHO When the measured RSRP value exceeds this
dRsrp GROUP threshold, an event A1 report will be sent.
MOD GUI Value Range: -140~-43
INTERF Unit: dBm
REQHO
GROUP Actual Value Range: -140~-43
IntraRat FreqPriI MOD None None Meaning: Indicates the trigger quantity for events
HoCom nterFreq INTRA A1/A2 of frequency-priority based inter-frequency
m HoA1Tr RATHO handover. The quantity can be either RSRP or RSRQ.
igQuan COMM The measured RSRP values are stable, varying little
LST with the load, and therefore there is little signal
INTRA fluctuation. The measured RSRQ values vary with the
RATHO load and are likely to reflect the signal quality of the
COMM cell in real time. For details, see 3GPP TS 36.331.
GUI Value Range: RSRP, RSRQ, BOTH
Unit: None
Actual Value Range: RSRP, RSRQ, BOTH
Default Value: RSRP
EutranIn FreqPri ADD None None Meaning: Indicates whether to enable or disable
terNFre BasedH EUTRA measurement for frequency-priority-based inter-
q oMeasFl NINTE frequency handovers to neighboring frequencies. In
ag RNFRE frequency-priority-based handovers, if the eNodeB
Q delivers frequencies to be measured based on
MOD frequency configuration, the frequencies with the
EUTRA FreqPriBasedHoMeasFlag parameter set to ENABLE
NINTE can be measured, and the frequencies with the
RNFRE FreqPriBasedHoMeasFlag parameter set to DISABLE
Q cannot be measured.
LST GUI Value Range: DISABLE(Disable),
EUTRA ENABLE(Enable)
NINTE Unit: None
RNFRE Actual Value Range: DISABLE, ENABLE
Q
Default Value: DISABLE(Disable)
CellHoP SpeedEv MOD None None Meaning: Indicates the number of handovers used to
araCfg aluated CELLH determine whether a UE in RRC-CONNECTED mode
Num OPARA moves at a high speed during a specified period. This
CFG parameter is one of the key parameters used for
LST redirection of high-speed UEs, which are determined
CELLH based on the number of handovers in a specified
OPARA period. If the number of handovers of a UE is greater
CFG than the value of this parameter during the period
specified by the SpeedEvaluatedPeriod parameter, the
UE is identified as a high-speed UE and triggers a
redirection to a high-speed frequency. This parameter
applies only to LTE TDD cells.
GUI Value Range: 1~16
Unit: None
Actual Value Range: 1~16
Default Value: 3
CellHoP SpeedEv MOD None None Meaning: Indicates the period during which the
araCfg aluatedP CELLH number of handovers is used to determine whether a
eriod OPARA UE in RRC_CONNECTED mode moves at a high
CFG speed. If the number of handovers of a UE in an
LST evaluation period specified by SpeedEvaluatedPeriod
CELLH is greater than SpeedEvaluatedNum, the eNodeB
OPARA determines that the UE moves at a high speed and
CFG initiates a measurement-based redirection to a high-
speed frequency. If the number of handovers of the
UE in the period is greater than or equal to
SpeedEvaluatedNumForFastUe, the eNodeB
determines that the UE moves at a fast speed. In this
situation, if the UE has GBR bearers, the eNodeB
initiates a handover for the UE to a frequency for
which the SpeedMobilityTargetInd option of the
MobilityTargetInd parameter is selected.
GUI Value Range: HS_30S(30s), HS_60S(60s),
HS_120S(120s), HS_180S(180s), HS_240S(240s),
HS_10S(10s), HS_15S(15s), HS_20S(20s),
HS_45S(45s)
Unit: None
Actual Value Range: HS_30S, HS_60S, HS_120S,
HS_180S, HS_240S, HS_10S, HS_15S, HS_20S,
HS_45S
Default Value: HS_30S(30s)
EutranIn InterFre ADD LOFD-0 Handov Meaning: Indicates whether an inter-frequency cell is
terNFre qHighSp EUTRA 81228 / er set to LOW_SPEED, HIGH_SPEED,
q eedFlag NINTE TDLOF Enhance ULTRA_HIGH_SPEED, or EXTRA_HIGH_SPEED.
RNFRE D-08020 ment at This parameter indicates the handover direction when
Q 5 Speed high- or low-speed handover algorithm is enabled for
MOD Mobility high-speed railway UEs.
EUTRA GUI Value Range: LOW_SPEED(Low speed Inter-
NINTE frequency), HIGH_SPEED(High speed Inter-
RNFRE frequency), ULTRA_HIGH_SPEED(Ultra high speed
Q Inter-frequency), EXTRA_HIGH_SPEED(Extra high
LST speed Inter-frequency)
EUTRA Unit: None
NINTE Actual Value Range: LOW_SPEED, HIGH_SPEED,
RNFRE ULTRA_HIGH_SPEED, EXTRA_HIGH_SPEED
Q
Default Value: LOW_SPEED(Low speed Inter-
frequency)
EutranIn NoHoFl ADD LBFD-0 Coverag Meaning: Indicates whether handovers of UEs to the
terFreq ag EUTRA 0201802 e Based neighboring cell are prohibited.
NCell NINTE / Inter- GUI Value Range: PERMIT_HO_ENUM(Permit Ho),
RFREQ TDLBF frequenc FORBID_HO_ENUM(Forbid Ho)
NCELL D-00201 y
802 Handov Unit: None
MOD
EUTRA LBFD-0 er Actual Value Range: PERMIT_HO_ENUM,
NINTE 0201804 Distance FORBID_HO_ENUM
RFREQ / Based Default Value: PERMIT_HO_ENUM(Permit Ho)
NCELL TDLBF Inter-
LST D-00201 frequenc
EUTRA 804 y
NINTE LBFD-0 Handov
RFREQ 0201805 er
NCELL / Service
TDLBF Based
D-00201 Inter-
805 frequenc
LOFD-0 y
02012 / Handov
TDLOF er
D-00201 Cell
2 Outage
Detectio
n and
Compen
sation
EutranIn CellRes ADD LBFD-0 Cell Meaning: Indicates whether to set the reselection
terNFre elPriorit EUTRA 0201803 Selectio priority of the neighboring E-UTRAN frequency. For
q yCfgInd NINTE / n and details about how UEs process frequency priorities
RNFRE TDLBF Re- during cell reselection, see section 5.2.4.1 of 3GPP TS
Q D-00201 selection 36.304 (V12.4.0).
MOD 803 GUI Value Range: NOT_CFG(Not configure),
EUTRA CFG(Configure)
NINTE Unit: None
RNFRE
Q Actual Value Range: NOT_CFG, CFG
ForbidR8R9UeAccessB41Sw:Off,
MOUeCompatEffectSw:Off, PerExtendBitSw:Off,
InterFddTddMeasComOptSw:Off
Hybrid
RAN
Sharing
Hybrid
RAN
Sharing
EutranE eNodeB ADD None None Meaning: Indicates the eNodeB identity of the
xternalC Id EUTRA external E-UTRAN cell. It uniquely identifies an
ell NEXTE eNodeB within a PLMN. The 28-bit E-UTRAN cell
RNALC identity is comprised of the cell identity and the
ELL eNodeB identity (represented by the most significant
ADD 20 bits). The cell global identity (CGI) of an E-
EUTRA UTRAN cell is comprised of the E-UTRAN cell
NEXTE identity and the PLMN ID. For details, see 3GPP TS
RNALC 36.413.
ELLBA GUI Value Range: 0~1048575
ND Unit: None
LST Actual Value Range: 0~1048575
EUTRA
NEXTE Default Value: None
RNALC
ELL
LST
EUTRA
NEXTE
RNALC
ELLBA
ND
MOD
EUTRA
NEXTE
RNALC
ELL
RMV
EUTRA
NEXTE
RNALC
ELL
RMV
EUTRA
NEXTE
RNALC
ELLBA
ND
EutranE CellId ADD LBFD-0 Coverag Meaning: Indicates the cell identity of the external E-
xternalC EUTRA 0201801 e Based UTRAN cell. It uniquely identifies a cell within an
ell NEXTE / Intra- eNodeB. The 28-bit E-UTRAN cell identity is
RNALC TDLBF frequenc comprised of the cell identity (represented by the least
ELL D-00201 y significant eight bits) and the eNodeB identity. The
ADD 801 Handov cell global identity (CGI) of an E-UTRAN cell is
EUTRA LBFD-0 er comprised of the E-UTRAN cell identity and the
NEXTE 0201802 Coverag PLMN ID. For details, see 3GPP TS 36.413.
RNALC / e Based GUI Value Range: 0~255
ELLBA TDLBF Inter- Unit: None
ND D-00201 frequenc
802 y Actual Value Range: 0~255
LST
EUTRA Handov Default Value: None
NEXTE er
RNALC
ELL
LST
EUTRA
NEXTE
RNALC
ELLBA
ND
MOD
EUTRA
NEXTE
RNALC
ELL
RMV
EUTRA
NEXTE
RNALC
ELL
RMV
EUTRA
NEXTE
RNALC
ELLBA
ND
EutranE DlEarfc ADD LOFD-0 RAN Meaning: Indicates the DL EARFCN of the external
xternalC n EUTRA 01036 / Sharing E-UTRAN cell. For details, see 3GPP TS 36.104.
ell NEXTE TDLOF with GUI Value Range:
RNALC D-00103 Commo 0~46589,54436~65535,66436~67335
ELL 6 n
Carrier Unit: None
MOD LOFD-0
EUTRA 01037 / RAN Actual Value Range:
NEXTE TDLOF Sharing 0~46589,54436~65535,66436~67335
RNALC D-00103 with Default Value: None
ELL 7 Dedicate
LST TDLBF d
EUTRA D-00201 Carrier
NEXTE 801 Coverag
RNALC TDLBF e Based
ELL D-00201 Intra-
802 frequenc
y
TDLBF Handov
D-00201 er
804
Coverag
TDLBF e Based
D-00201 Inter-
805 frequenc
TDLOF y
D-00105 Handov
0 er
LOFD-0 Distance
70206 Based
Inter-
frequenc
y
Handov
er
Service
Based
Inter-
frequenc
y
Handov
er
Mobility
between
LTE
TDD
and LTE
FDD
Hybrid
RAN
Sharing
EutranE PhyCellI ADD LBFD-0 Coverag Meaning: Indicates the physical cell ID of the external
xternalC d EUTRA 0201801 e Based E-UTRAN cell. For details, see 3GPP TS 36.331.
ell NEXTE LBFD-0 Intra- GUI Value Range: 0~503
RNALC 0201802 frequenc
ELL y Unit: None
LBFD-0 Handov Actual Value Range: 0~503
MOD 0201803
EUTRA er Default Value: None
NEXTE Coverag
RNALC e Based
ELL Inter-
LST frequenc
EUTRA y
NEXTE Handov
RNALC er
ELL Cell
Selectio
n and
Reselect
ion
EutranE Tac ADD LBFD-0 Coverag Meaning: Indicates the tracking area code (TAC) of
xternalC EUTRA 0201801 e Based the external E-UTRAN cell. Two TAC values
ell NEXTE / Intra- 0x0000(0) and 0xFFFE(65534) are reserved according
RNALC TDLBF frequenc to the protocol and will not be used in future versions.
ELL D-00201 y Therefore, do not use 0 or 65534 as a TAC value in
MOD 801 Handov TAC planning or configuration.
EUTRA LBFD-0 er GUI Value Range: 0~65535
NEXTE 0201802 Coverag Unit: None
RNALC / e Based
ELL TDLBF Inter- Actual Value Range: 0~65535
EutranE eNodeB ADD None None Meaning: Indicates the eNodeB identity of the
xternalC Id EUTRA external E-UTRAN cell. It uniquely identifies an
ellPlmn NEXTE eNodeB within a PLMN. The 28-bit E-UTRAN cell
RNALC identity is comprised of the cell identity and the
ELLPL eNodeB identity (represented by the most significant
MN 20 bits). The cell global identity (CGI) of an E-
LST UTRAN cell is comprised of the E-UTRAN cell
EUTRA identity and the PLMN ID. For details, see 3GPP TS
NEXTE 36.413.
RNALC GUI Value Range: 0~1048575
ELLPL Unit: None
MN
Actual Value Range: 0~1048575
RMV
EUTRA Default Value: None
NEXTE
RNALC
ELLPL
MN
EutranE CellId ADD LOFD-0 RAN Meaning: Indicates the cell identity of the external E-
xternalC EUTRA 01036 / Sharing UTRAN cell. It uniquely identifies a cell within an
ellPlmn NEXTE TDLOF with eNodeB. The 28-bit E-UTRAN cell identity is
RNALC D-00103 Commo comprised of the cell identity (represented by the least
ELLPL 6 n significant eight bits) and the eNodeB identity. The
MN LOFD-0 Carrier cell global identity (CGI) of an E-UTRAN cell is
LST 01037 / RAN comprised of the E-UTRAN cell identity and the
EUTRA TDLOF Sharing PLMN ID. For details, see 3GPP TS 36.413.
NEXTE D-00103 with GUI Value Range: 0~255
RNALC 7 Dedicate Unit: None
ELLPL d
MN Carrier Actual Value Range: 0~255
EutranIn LocalCe ADD None None Meaning: Indicates the cell ID of the local cell. It
traFreq llId EUTRA uniquely identifies a cell within an eNodeB.
NCell NINTR GUI Value Range: 0~255
AFREQ
NCELL Unit: None
EutranIn eNodeB ADD None None Meaning: Indicates the eNodeB identity of the intra-
traFreq Id EUTRA frequency neighboring cell. It uniquely identifies an
NCell NINTR eNodeB within a PLMN. The 28-bit E-UTRAN cell
AFREQ identity is comprised of the cell identity and the
NCELL eNodeB identity (represented by the most significant
DSP 20 bits). The cell global identity (CGI) of an E-
EUTRA UTRAN cell is comprised of the E-UTRAN cell
NEXTE identity and the PLMN ID. For details, see 3GPP TS
NDEDN 36.413.
CELL GUI Value Range: 0~1048575
DSP Unit: None
EUTRA Actual Value Range: 0~1048575
NINTR
AFREQ Default Value: None
NCELL
LST
EUTRA
NINTR
AFREQ
NCELL
MOD
EUTRA
NINTR
AFREQ
NCELL
RMV
EUTRA
NEXTE
NDEDN
CELL
RMV
EUTRA
NINTR
AFREQ
NCELL
EutranIn CellId ADD LBFD-0 Coverag Meaning: Indicates the local identity of the intra-
traFreq EUTRA 0201801 e Based frequency neighboring cell. It uniquely identifies a
NCell NINTR / Intra- cell within an eNodeB. The 28-bit E-UTRAN cell
AFREQ TDLBF frequenc identity is comprised of the cell identity (represented
NCELL D-00201 y by the least significant eight bits) and the eNodeB
DSP 801 Handov identity. The cell global identity (CGI) of an E-
EUTRA er UTRAN cell is comprised of the E-UTRAN cell
NEXTE identity and the PLMN ID. For details, see 3GPP TS
NDEDN 36.413.
CELL GUI Value Range: 0~255
DSP Unit: None
EUTRA Actual Value Range: 0~255
NINTR
AFREQ Default Value: None
NCELL
LST
EUTRA
NINTR
AFREQ
NCELL
MOD
EUTRA
NINTR
AFREQ
NCELL
RMV
EUTRA
NEXTE
NDEDN
CELL
RMV
EUTRA
NINTR
AFREQ
NCELL
CellStan LocalCe LST None None Meaning: Indicates the local ID of the cell. It uniquely
dardQci llId CELLS identifies a cell within a BS.
TANDA GUI Value Range: 0~255
RDQCI
Unit: None
MOD
CELLS Actual Value Range: 0~255
TANDA Default Value: None
RDQCI
CellStan Qci LST LBFD-0 Basic Meaning: Indicates the QoS class identifier (QCI) of
dardQci CELLS 02025 / Scheduli an evolved packet system (EPS) bearer. Different
TANDA TDLBF ng QCIs indicate different QoS requirements, such as the
RDQCI D-00202 Dynami packet delay budget, packet error loss rate, and
MOD 5 c resource type. For details, see Table 6.1.7 in 3GPP TS
CELLS LOFD-0 Scheduli 23.203.
TANDA 0101502 ng GUI Value Range: QCI1(QCI 1), QCI2(QCI 2),
RDQCI / QCI3(QCI 3), QCI4(QCI 4), QCI5(QCI 5), QCI6(QCI
TDLOF 6), QCI7(QCI 7), QCI8(QCI 8), QCI9(QCI 9)
D-00101 Unit: None
502
Actual Value Range: QCI1, QCI2, QCI3, QCI4, QCI5,
QCI6, QCI7, QCI8, QCI9
Default Value: None
CellStan IntraFre MOD LBFD-0 Coverag Meaning: Indicates the ID of a parameter group
dardQci qHoGro CELLS 0201801 e Based related to intra-frequency handover.
upId TANDA / Intra- GUI Value Range: 0~9
RDQCI TDLBF frequenc
D-00201 y Unit: None
LST
CELLS 801 Handov Actual Value Range: 0~9
TANDA er Default Value: 0
RDQCI
CellStan QciPrior MOD LBFD-0 Coverag Meaning: Indicates the QCI priority used by each
dardQci ityForH CELLS 0201801 e Based QCI-based handover algorithm. A larger value of this
o TANDA LBFD-0 Intra- parameter indicates a lower priority. This parameter
RDQCI 0201802 frequenc applies to handover parameter selection based on QCI
LST y priorities, target frequency selection in service-based
LBFD-0 Handov inter-frequency handovers, and inter-RAT handover
CELLS 0201804
TANDA er policy selection. For a service that involves all the
RDQCI LBFD-0 Coverag preceding selection, the setting of this parameter
0201805 e Based determines the handover parameter, target frequency,
LOFD-0 Inter- and handover policy corresponding to a QCI.
01072 frequenc GUI Value Range: 1~9
LOFD-0 y Unit: None
01073 Handov
er Actual Value Range: 1~9
CellExte Extende ADD LBFD-0 Extende Meaning: Indicates the extended QoS Class Identifier
ndedQci dQci CELLE 02032 d-QCI (QCI), which is required by the operator for service
XTEND differentiation.
EDQCI GUI Value Range: 10~254
LST Unit: None
CELLE
XTEND Actual Value Range: 10~254
EDQCI Default Value: None
MOD
CELLE
XTEND
EDQCI
RMV
CELLE
XTEND
EDQCI
CellExte LocalCe ADD None None Meaning: Indicates the local ID of the cell. It uniquely
ndedQci llId CELLE identifies a cell within a BS.
XTEND GUI Value Range: 0~255
EDQCI
Unit: None
LST
CELLE Actual Value Range: 0~255
XTEND Default Value: None
EDQCI
MOD
CELLE
XTEND
EDQCI
RMV
CELLE
XTEND
EDQCI
CellExte IntraFre ADD LBFD-0 Coverag Meaning: Indicates the ID of a parameter group
ndedQci qHoGro CELLE 0201801 e Based related to intra-frequency handover.
upId XTEND / Intra- GUI Value Range: 0~9
EDQCI TDLBF frequenc
D-00201 y Unit: None
MOD
CELLE 801 Handov Actual Value Range: 0~9
XTEND er Default Value: 0
EDQCI
LST
CELLE
XTEND
EDQCI
EutranIn CellMea ADD LBFD-0 Coverag Meaning: Indicates the priority of measurement on the
traFreq sPriority EUTRA 0201801 e Based intra-frequency neighboring cell. The eNodeB
NCell NINTR / Intra- preferentially contains the information about a
AFREQ TDLBF frequenc neighboring cell with this priority set to
NCELL D-00201 y HIGH_PRIORITY while delivering a measurement
MOD 801 Handov configuration.
EUTRA LBFD-0 er GUI Value Range: LOW_PRIORITY(Low Priority),
NINTR 0201804 Distance HIGH_PRIORITY(High Priority)
AFREQ / Based Unit: None
NCELL TDLBF Inter-
D-00201 frequenc Actual Value Range: LOW_PRIORITY,
LST HIGH_PRIORITY
EUTRA 804 y
NINTR LBFD-0 Handov Default Value: LOW_PRIORITY(Low Priority)
AFREQ 0201805 er
NCELL / Service
TDLBF Based
D-00201 Inter-
805 frequenc
y
Handov
er
IntraFre LocalCe ADD None None Meaning: Indicates the local ID of the cell. It uniquely
qHoGro llId INTRA identifies a cell within a BS.
up FREQH GUI Value Range: 0~255
OGROU
P Unit: None
IntraFre IntraFre ADD None None Meaning: Indicates the ID of the parameter group
qHoGro qHoGro INTRA related to intra-frequency handover.
up upId FREQH GUI Value Range: 0~9
OGROU
P Unit: None
EutranIn LocalCe ADD None None Meaning: Indicates the cell ID of the local cell. It
terNFre llId EUTRA uniquely identifies a cell within an eNodeB.
q NINTE GUI Value Range: 0~255
RNFRE
Q Unit: None
EutranIn LocalCe ADD None None Meaning: Indicates the cell ID of the local cell. It
terFreq llId EUTRA uniquely identifies a cell within an eNodeB.
NCell NINTE GUI Value Range: 0~255
RFREQ
NCELL Unit: None
EutranIn eNodeB ADD None None Meaning: Indicates the eNodeB identity of the inter-
terFreq Id EUTRA frequency neighboring cell. It uniquely identifies an
NCell NINTE eNodeB within a PLMN. The 28-bit E-UTRAN cell
RFREQ identity is comprised of the cell identity and the
NCELL eNodeB identity (represented by the most significant
DSP 20 bits). The cell global identity (CGI) of an E-
EUTRA UTRAN cell is comprised of the E-UTRAN cell
NINTE identity and the PLMN ID. For details, see 3GPP TS
RFREQ 36.413.
NCELL GUI Value Range: 0~1048575
LST Unit: None
EUTRA Actual Value Range: 0~1048575
NINTE
RFREQ Default Value: None
NCELL
MOD
EUTRA
NINTE
RFREQ
NCELL
RMV
EUTRA
NINTE
RFREQ
NCELL
EutranIn CellId ADD LBFD-0 Coverag Meaning: Indicates the local identity of the inter-
terFreq EUTRA 0201802 e Based frequency neighboring cell. It uniquely identifies a
NCell NINTE Inter- cell within an eNodeB. The 28-bit E-UTRAN cell
RFREQ frequenc identity is comprised of the cell identity (represented
NCELL y by the least significant eight bits) and the eNodeB
DSP Handov identity. The cell global identity (CGI) of an E-
EUTRA er UTRAN cell is comprised of the E-UTRAN cell
NINTE identity and the PLMN ID. For details, see 3GPP TS
RFREQ 36.413.
NCELL GUI Value Range: 0~255
LST Unit: None
EUTRA Actual Value Range: 0~255
NINTE
RFREQ Default Value: None
NCELL
MOD
EUTRA
NINTE
RFREQ
NCELL
RMV
EUTRA
NINTE
RFREQ
NCELL
CellStan InterFre MOD LBFD-0 Coverag Meaning: Indicates the ID of a parameter group
dardQci qHoGro CELLS 0201802 e Based related to inter-frequency handovers.
upId TANDA / Inter- GUI Value Range: 0~9
RDQCI TDLBF frequenc
D-00201 y Unit: None
LST
CELLS 802 Handov Actual Value Range: 0~9
TANDA LBFD-0 er Default Value: 0
RDQCI 0201804 Distance
/ Based
TDLBF Inter-
D-00201 frequenc
804 y
LBFD-0 Handov
0201805 er
/ Service
TDLBF Based
D-00201 Inter-
805 frequenc
y
Handov
er
CellExte InterFre ADD LBFD-0 Coverag Meaning: Indicates the ID of a parameter group
ndedQci qHoGro CELLE 0201802 e Based related to inter-frequency handover.
upId XTEND / Inter- GUI Value Range: 0~9
EDQCI TDLBF frequenc
D-00201 y Unit: None
MOD
CELLE 802 Handov Actual Value Range: 0~9
XTEND LBFD-0 er Default Value: 0
EDQCI 0201804 Distance
LST / Based
CELLE TDLBF Inter-
XTEND D-00201 frequenc
EDQCI 804 y
LBFD-0 Handov
0201805 er
/ Service
TDLBF Based
D-00201 Inter-
805 frequenc
y
Handov
er
CnOper CnOper LST None None Meaning: Indicates the ID of the operator.
atorHoC atorId CNOPE GUI Value Range: 0~5
fg RATOR
HOCFG Unit: None
EutranN LocalCe ADD None None Meaning: Indicates the ID of the local cell. It uniquely
FreqRan llId EUTRA identifies a cell within an eNodeB.
Share NNFRE GUI Value Range: 0~255
QRANS
HARE Unit: None
EutranN DlEarfc ADD LOFD-0 RAN Meaning: Indicates the DL EARFCN of the operator
FreqRan n EUTRA 01036 / Sharing that shares the neighboring E-UTRAN frequency. For
Share NNFRE TDLOF with details, see the 3GPP TS 36.104.
QRANS D-00103 Commo GUI Value Range:
HARE 6 n 0~46589,54436~65535,66436~67335
LST TDLOF Carrier
Unit: None
EUTRA D-00111 MOCN
NNFRE 2 Flexible Actual Value Range:
QRANS Priority 0~46589,54436~65535,66436~67335
LOFD-0
HARE 70206 Based Default Value: None
MOD Campin
EUTRA g
NNFRE Hybrid
QRANS RAN
HARE Sharing
RMV
EUTRA
NNFRE
QRANS
HARE
InterFre LocalCe ADD None None Meaning: Indicates the local ID of the cell. It uniquely
qHoGro llId INTERF identifies a cell within a BS.
up REQHO GUI Value Range: 0~255
GROUP
Unit: None
LST
INTERF Actual Value Range: 0~255
REQHO Default Value: None
GROUP
MOD
INTERF
REQHO
GROUP
RMV
INTERF
REQHO
GROUP
InterFre InterFre ADD None None Meaning: Indicates the ID of the parameter group
qHoGro qHoGro INTERF related to inter-frequency handover.
up upId REQHO GUI Value Range: 0~9
GROUP
Unit: None
LST
INTERF Actual Value Range: 0~9
REQHO Default Value: None
GROUP
MOD
INTERF
REQHO
GROUP
RMV
INTERF
REQHO
GROUP
EutranIn VoipPrio ADD LBFD-0 Coverag Meaning: Indicates the frequency priority of providing
terNFre rity EUTRA 0201802 e Based VoIP services on the intra-RAT neighboring
q NINTE / Inter- frequency. A larger value of this parameter indicates a
RNFRE TDLBF frequenc higher priority. During coverage-based inter-
Q D-00201 y frequency handovers with VoipMeasFreqPriSwitch
MOD 802 Handov being on, the eNodeB selects and delivers the
EUTRA er neighboring frequencies based on the frequency
NINTE priorities when starting measurements. The eNodeB
RNFRE preferentially delivers the frequency with the highest
Q priorities to VoIP UEs. If this parameter is set to 0,
this neighboring frequency is not prioritized.
LST
EUTRA GUI Value Range: 0~16
NINTE Unit: None
RNFRE Actual Value Range: 0~16
Q
Default Value: 1
ServiceI CnOper ADD LBFD-0 Service Meaning: Indicates the ID of the operator.
fHoCfg atorId SERVIC 0201805 Based GUI Value Range: 0~5
Group EIFHO Inter-
CFGGR frequenc Unit: None
OUP y Actual Value Range: 0~5
LST Handov Default Value: None
SERVIC er
EIFHO
CFGGR
OUP
MOD
SERVIC
EIFHO
CFGGR
OUP
RMV
SERVIC
EIFHO
CFGGR
OUP
ServiceI ServiceI ADD LBFD-0 Service Meaning: Indicates the ID of the service-based inter-
fHoCfg fHoCfg SERVIC 0201805 Based frequency handover policy group.
Group GroupId EIFHO / Inter- GUI Value Range: 0~9
CFGGR TDLBF frequenc
OUP D-00201 y Unit: None
ServiceI CnOper ADD LBFD-0 Service Meaning: Indicates the ID of the operator.
fDlEarfc atorId SERVIC 0201805 Based GUI Value Range: 0~5
nGrp EIFDLE / Inter-
ARFCN TDLBF frequenc Unit: None
GRP D-00201 y Actual Value Range: 0~5
LST 805 Handov Default Value: None
SERVIC TDLOF er
EIFDLE D-07022 Service-
ARFCN 8 Request
GRP Based
MOD Inter-
SERVIC frequenc
EIFDLE y
ARFCN Handov
GRP er
RMV
SERVIC
EIFDLE
ARFCN
GRP
ServiceI ServiceI ADD LBFD-0 Service Meaning: Indicates the ID of the service-based inter-
fDlEarfc fHoCfg SERVIC 0201805 Based frequency handover policy group.
nGrp GroupId EIFDLE / Inter- GUI Value Range: 0~9
ARFCN TDLBF frequenc
GRP D-00201 y Unit: None
GlobalP QciPara MOD None None Meaning: Indicates whether parameters in QciPara,
rocSwitc EffectFl GLOBA CellQciPara, and CnOperatorQciPara MOs take
h ag LPROC effect. The parameters do not take effect by default. If
SWITC this parameter is set to OFF, parameters in
H StandardQci, ExtendedQci, CellStandardQci,
LST CellExtendedQci, CnOperatorStandardQci, and
GLOBA CnOperatorExtendedQci MOs take effect and
LPROC parameters in QciPara, CellQciPara, and
SWITC CnOperatorQciPara MOs do not take effect. If this
H parameter is set to ON, parameters in QciPara,
CellQciPara, and CnOperatorQciPara MOs take effect
and parameters in StandardQci, ExtendedQci,
CellStandardQci, CellExtendedQci,
CnOperatorStandardQci, and CnOperatorExtendedQci
MOs do not take effect.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
Default Value: OFF(Off)
CnOper CnOper LST None None Meaning: Indicates the index of the operator.
atorStan atorId CNOPE GUI Value Range: 0~5
dardQci RATOR
STAND Unit: None
ARDQC Actual Value Range: 0~5
I Default Value: None
MOD
CNOPE
RATOR
STAND
ARDQC
I
CnOper ServiceI MOD LBFD-0 Service Meaning: Indicates the ID of the service-based inter-
atorStan fHoCfg CNOPE 0201805 Based frequency handover policy group.
dardQci GroupId RATOR Inter- GUI Value Range: 0~9
STAND frequenc
ARDQC y Unit: None
I Handov Actual Value Range: 0~9
LST er Default Value: 0
CNOPE
RATOR
STAND
ARDQC
I
CnOper CnOper ADD LBFD-0 Extende Meaning: Indicates the index of the operator.
atorExte atorId CNOPE 02032 d-QCI GUI Value Range: 0~5
ndedQci RATOR
EXTEN Unit: None
DEDQC Actual Value Range: 0~5
I Default Value: None
LST
CNOPE
RATOR
EXTEN
DEDQC
I
MOD
CNOPE
RATOR
EXTEN
DEDQC
I
RMV
CNOPE
RATOR
EXTEN
DEDQC
I
CnOper Extende ADD LBFD-0 Extende Meaning: Indicates the extended QoS Class Identifier
atorExte dQci CNOPE 02032 d-QCI (QCI), which is required by the operator for user
ndedQci RATOR differentiation.
EXTEN GUI Value Range: 10~254
DEDQC
I Unit: None
CnOper ServiceI ADD LBFD-0 Service Meaning: Indicates the ID of the service-based inter-
atorExte fHoCfg CNOPE 0201805 Based frequency handover policy group.
ndedQci GroupId RATOR Inter- GUI Value Range: 0~9
EXTEN frequenc
DEDQC y Unit: None
I Handov Actual Value Range: 0~9
MOD er Default Value: 0
CNOPE
RATOR
EXTEN
DEDQC
I
LST
CNOPE
RATOR
EXTEN
DEDQC
I
CellAlg LocalCe DSP None None Meaning: Indicates the local ID of the cell. It uniquely
oSwitch llId CELLU identifies a cell within a BS.
LCAMC GUI Value Range: 0~255
CLUST
ER Unit: None
DistBas LocalCe LST None None Meaning: Indicates the local identity of the cell. It
edHO llId DISTB uniquely identifies a cell within an eNodeB.
ASEDH GUI Value Range: 0~255
O
Unit: None
MOD
DISTB Actual Value Range: 0~255
ASEDH Default Value: None
O
9 Counters
10 Glossary
11 Reference Documents