Before every use you should carefully check the operability of the implants and the operating instruments. They should be free of
damages. If there are any cracks, fractures, discolouration, deformation or any damages on the implants, which may be due to
unsuitable storing, imperfect sterilization or preliminary inefficient treatment, the use of the implant is prohibited. The assembly,
perfect fitting and operation of the implants and all the necessary instruments should be tested. Perfect fitting and operation,
appropriate dimensions and positions should be checked in all cases.
The set of tools and implants can only be applied by doctors with appropriate qualifications and special information and
experience in the field of using implants.
The doctor who performs the operation is responsible for choosing the correct indication, the type of the implants and the
operation technology.
Contraindication
Implantation is not recommended if the patient's health condition makes it difficult to accept it or problems are expected during the
recovery process e.g. decreased circulation, weak quality or quantity bone system, impossibility of rehabilitation due to the mental
condition of the patient etc.
General warnings
Before the operation the patient should be informed about the possible disadvantages of the implant. By choosing the appropriate
implant the type of the bone fracture, the weight and activity of the patient should be taken into consideration. The solidity of the
implant is restricted, so it is necessary to avoid overloading it by overweight. The biomechanical loading of the implant should be
minimized, as much as possible.
During the application of the implant the process of recovering is to be controlled. By repetitive loading or by protracted bone
recovering the implants may be deformed, dislocated. This needs intervention in time. Repeated deformation of the implant
should be avoided. The implants are only for one-time use, a re-implantation is prohibited. The type and the size of the implants
should be defined according to the specific case. Before operation the user's manual of the implants should be studied carefully.
Applied materials
The applied materials are of best quality, specially developed for implants with high solidity, made of non magnetic stainless steel
and titan alloys.
Combined use of products of other manufacturers may start damaging processes, which the Medimetal Ltd. can't take the
responsibility for.
The implants come clean, without any production pollution for packaging. Before use circumstances are to be assured where the
integrity of the packaging will be preserved. The storage should be in a clean, dry place avoiding extra temperature and
chemicals.
Sterilisation
Before use unpack the implant and sterilize due to the prescriptions.
Avoid the touch by bare hand. The sterilisation of the instruments should be done together with the tray. The instructions of the
producers should always be considered.
:9 7
1050668 EN ISO 13485
3
1.4
Implants for titanium elastic pin system
System of implants:
TITANIUM ELASTIC PIN
The titanium elastic pins are used for limb fractures in childhood. There are good results in treatment of
children suffering from humerus, ulna, femur and tibia fractures. Thanks to the quality of the materials the
pins behave like flexible ones, and they can support the damaged bone with the necessary stability.
The stability and the original position can be ensured by the simultaneus use of two titanium elastic pins and
the pins are based on both endpoints an in the middle section on the medullary cavity. The corresponding
results of the surgical pins in axial loading, stability, split tensile, and turning anti-slip fastening and bending
rigidity is ensured. The thickness of titanium elastic pins are right if they fill the two-third part of the diameter
of the medullary cavity up. If necessary, the titanium elastic pin can be bent modelled. The required length
can be pruduced during surgery by cutting.
The titanium elastic pin application techniques to ensure the correctness os the doctor performing surgery.
Titanium elastic pin, short, cat. nr.: from 35900-20220 to 35900-40220 (titanium alloy)
Titanium elastic pin, long, cat. nr.: from35900-20440 to 35900-40440 (titanium alloy)
The end design of the titanium elastic pins helps for the
reposition and it can be anchored on the upper end of medullary
cavity.
The range of the diameters can be divided by the using of the
colour codes.
4 1008
1.4
Implants for titanium elastic pin system
Cat. no
L
(mm) (mm) titanium alloy
220 1,5 35900-15220
220 2,0 35900-20220
220 2,5 35900-25220
220 3,0 35900-30220
220 3,5 35900-35220
220 4,0 35900-40220
Cat. no
L
(mm) (mm) titanium alloy
330 1,5 35900-15330
440 1,5 35900-15440
440 2,0 35900-20440
440 2,5 35900-25440
440 3,0 35900-30440
440 3,5 35900-35440
440 4,0 35900-40440
5
1.4
Surgical set for titanium elastic pin system
TITANIUM ELASTIC PIN
Surgical set
Instrument set for titanium elastic pin system complete with instruments: cat. nr. 95900-00000
(without implants)
Empty tray with plastic holder: cat. nr.: 95900-10000
1 2 3 4 5 6
7
10
8
11
9
12
13 14
6
1.4
Surgical set for titanium elastic pin system
7
1.4
Surgical set for titanium elastic pin system
TITANIUM ELASTIC PIN
8
1.4
Surgical set for titanium elastic pin system
9
Notes
1.4
TITANIUM ELASTIC PIN
10
Medical Products Manufacturing and Trading Ltd.