You are on page 1of 4

UOJZ.S771 - Control Units, System http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...

UOJZ.S771
Control Units, System

Page Bottom

Control Units, System

See General Information for Control Units, System

SIMPLEX TIME RECORDER CO S771


50 TECHNOLOGY DR
WESTMINSTER, MA 01441 USA

UL 864 9th Edition Listed

Control Unit Initiating Signaling


Model System Type(s) Device Type(s) Type(s)

Control Units

4010-9102 (a) (b), 4010-9101 (a) (b), 4010-9101SP (a) (b), 4010-9201 (a) (b), 4010-9201SP (a) (b), 4010-9202
(a) (b)

L A, M, SS, WF C, March, NC

AUX, LS A, M, WF C, March, NC

RS (PPU) A, M, SS, WF DAC, OT, Rev Pol

P (PPU) A, M, SS, WF C, DAC, MX, NC, OT

CS (PPU) A, M, SS, WF DAC, OT

P (PPU) A, M, SS, WF C, DAC, MX, NC, OT

4010ES Models 4010-9423, -9428, -9501, -9502, -9503, -9504, -9521, -9522, -9523, -9524, -9527, -9528, -9529,
and -9530, Models 4010-9401, -9402, -9403, -9404, -9405, -9406, -9421, -9422, -9425, -9426, -9525 and -9526 ,
Models 4010-9401BA, -9402BA, 9501BA, 9502BA, 9503BA, 9504BA, 9421BA, 9422BA, 9425BA, 9426BA, 9521BA,
9522BA, 9523BA, 9524BA, 9525BA, 9526BA, 9527BA, 9528BA, 9529BA, and 9530BA; 4010ESS Models 4010-9601,
-9602, -9603, -9604, -9606, -9609, -9610, -9621, -9622, -9623, -9624, -9701, -9702, -9711, -9712, -9721, -9722
and -9602BA * Note: "BA" at the end of the model number designates "built in America"

L A, M, SS, WF C, March, NC

AUX, L A, M, WF C, March, NC

RS (PPU) A, M, SS, WF DAC, OT, Rev Pol

CS (PPU) A, M, SS, WF DAC, OT

P (RU) A, M, SS, WF MX, OT

P (PPU) A, M, SS, WF DAC, MX, OT

4100-9231, -9232, -9233, -9234, -9235, -9236, -9237, -9238, -9513, -9531, -9532, -9533, -9534

AUX, CS (PPU), L, P (PPU), P A, M, SS, WF C, DAC, MX, NC


(RU)

Supervising Station

4190-8403 (b) (+), -8405 (b) (+) P (RU) A, M, SS, WF DAC, MX, OT

CS (RU) A, M, SS, WF DAC

2120 Series (c) AUX, CS (PPU), L, LS, P A, M, SS, WF, WSS C, DAC, MX, March,
(RU), P, RS (PPU) NC

3400-8113, 3700-8113 P (RU) A, M, SS, WF MX

1 of 4 3/17/2017 11:28 AM
UOJZ.S771 - Control Units, System http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...

4004-9201CE, 4004-9202CE, 4004-9301, L A, M, SS, WF C, March, NC


4004-9302

4005-9101 (d), 4005-9102 (d), 4005-9150 (d) L A, M, SS, WF C, March, NC

AUX, LS A, M, WF C, March, NC

P (PPU) A, M, SS, WF NC

RS (PPU) A, M, SS, WF DAC, NC, OT

CS (PPU) A, M, SS, WF DAC

P (PPU) A, M, SS, WF NC

P (PPU) A, M, SS, WF NC

4006-9101, 4006-9102, 4006-9121, 4006-9122, 4008-9101, 4008-9102, 4008-9121, 4008-9122

L A, M, SS, WF March, NC

AUX A, M, WF NC

RS (PPU) A, M, SS, WF DAC, Rev Pol

CS (PPU) A, M, SS, WF DAC

RS (PPU) A, M, SS, WF DAC, OT, Rev Pol

4007-9101, 4007-9101AR, 4007-9102, AUX A, M, WF NC


4007-9201, and 4007-9202

L A, M, SS, WF March, NC

RS (PPU) A, M, SS, WF DAC, Rev Pol

CS (PPU) A, M, SS, WF DAC

4100-9001 (b), 4100-9111 (b), 4100-9112(b), 4100-9113(b), 4100-9114 (b), 4100-9115(b), 4100-9116(b),
4100-9121(b), 4100-9122 (b), 4100-9211 (b), 4100-9212 (b), 4100-9213 (b), 4100-9214 (b), 4100-9222 (b),
4100-9311(b), 4100-9314 (b)

L A, M, SS, WF C, March, NC

AUX, LS A, M, WF NC

RS (PPU) A, M, SS, WF DAC, OT, Rev Pol

P (PPU) A, M, SS, WF DAC, MX, OT

CS (PPU) A, M, SS, WF DAC, OT

P (RU) A, M, SS, WF MX, NC

4100-9131 (b), 4100-9132 (b), 4100-9133 (b), 4100-9230(b) 4100-9331 (b)

CS (PPU) A, M, SS, WF DAC, OT

P (PPU) A, M, SS, WF DAC, OT

4100-9600 (b), 4100-9601 (b), 4100-9602 (b) L A, M, SS, WF C, March, NC

CS (PPU) A, M, SS, WF DAC, OT

P (PPU) A, M, SS, WF DAC, MX, OT

CS (PPU) A, M, SS, WF DAC, OT

UL 864 10th Edition Listed

Fiber Card, Model(s) Subassembly Models 4000-6001, -6002, -6003, -6004

UL 864 9th Edition Listed

Audio Isolation Harness, Model(s) 734-231

Audio Isolation Module, Model(s) 743-302

Control Units, Model(s) 4100-9215, 4100-9511, 4100-9512

Drawer style/low silhouette rack mount controls, Model(s) 4010-9101*, 4010-9101SP*, 4010-9102*, 4010-9201*, 4010-9201SP*,
4010-9202*, 4100-8701*, 4120-8700*, 4120-8701*, 4120-8721*

PC anunnciator, Model(s) 4190-7017, -7018, -7019

2 of 4 3/17/2017 11:28 AM
UOJZ.S771 - Control Units, System http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...

remote annunciator, Model(s) 4190-7015, -7016, -7019

Subassemblies, Model(s) 4100-7150, 4100-7158, 4100-7152, 4100-7154, 4100-7156, 4100-9833, 4100-6038 RS-232(b) master controller
replacement

Subassembly, 24 Zone LED Module, Model(s) 4007-9805

Subassembly, 25 V Regulator Module, Model(s) 4007-9802

Subassembly, Dual Class A Isolator Module, Model(s) 4007-9804

Subassembly, IDNet+ Loop Module, Model(s) 4007-9803

Subassembly, Remote Service Gateway, Model(s) 4190-6106

Subassembly, SDACT Module, Model(s) 4007-9806

Subassembly, Alarm Relay Module, Model(s) 4007-9809

Subassembly, City Circuit Module with Disconnect Switch, Model(s) 4007-9807

Subassembly, City Circuit Module without Disconnect Switch, Model(s) 4007-9808

Subassembly, CPU and User Interface, Model(s) 0566-1023

Subassembly, Dual RS232 Module, Model(s) 4007-9812

Subassembly, Fiber-Optic Media Module, Model(s) 4007-9814

Subassembly, Flat Network Card Interface, Model(s) 4007-9810

Subassembly, IDNAC Power Supply, Model(s) 0566-989

Subassembly, NAC Power Supply, Model(s) 0566-1030

Subassembly, Wired Media Module, Model(s) 4007-9813

Subassembly, Zone/Relay Module, Model(s) 4007-9801

Model(s) 4100-9511, 4100-9512

L - Local System

A - Automatic Fire Alarm: thermostats, smoke detectors, etc.

M - Manual Fire Alarm: manually operated boxes

SS - Supervisory: gate valves, water-level switches, temperature switches, carbon monoxide alarm, residential fire alarm control units, etc.

WF - Waterflow Alarm: waterflow switches

C - Coded

March - March Time

NC - Noncoded, Steady, Temporal 3 Pattern, etc.

AUX - Auxiliary System

LS - Local System with Shunt-type Connection to Master Box

RS (PPU) - Remote Station System (Protected Premises Unit)

DAC - Digital Alarm Communicator

OT - Other Transmission Technologies

Rev Pol - Reverse Polarity

P (PPU) - Proporiety System (Protected Premises Unit)

MX - Multiplex

CS (PPU) - Central Station System (Protected Premises Unit)

P (RU) - Proporiety System (Supervising Station Receiving Unit)

CS (RU) - Central Station System (Supervising Station Receiving Unit)

P - Proprietary System

WSS - Watchman's Supervisory Service

(a) - System control unit with additional emergency voice communications, supplementary tape deck with pre-recorded message and paging when
Type is Local System (L). When Type is Proprietary (PPU) and Type Signaling is Coded (C) or When Type Signaling is Digital Alarm Communicator
(DAC) - see footnote +.

(b) - Complementary Listed under DAYRC, AMCX, APOU. For Digital Alarm Communication (DAC), refer to note +.

(c) - When Type is Central Station (PPU) or Type Signaling is Digital Alarm Communicator (DAC) - see footnote +.

3 of 4 3/17/2017 11:28 AM
UOJZ.S771 - Control Units, System http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...

(d) - When Type is Proprietary (PPU) or Type Signaling is Digital Alarm Communicator (DAC) - see footnote +.

* - Also suitable for releasing device services.

+ - Must be employed with additional specific Listed device(s) as indicated in installation instructions and wiring diagrams to provide indicated type
service. Suitable for sprinkler supervisory service.

Last Updated on 2017-02-25

Questions? Print this page Terms of Use Page Top

© 2017 UL LLC

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading
manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission
from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format:
"© 2017 UL LLC".

4 of 4 3/17/2017 11:28 AM