Control Units
4010-9102 (a) (b), 4010-9101 (a) (b), 4010-9101SP (a) (b), 4010-9201 (a) (b), 4010-9201SP (a) (b), 4010-9202
(a) (b)
L A, M, SS, WF C, March, NC
AUX, LS A, M, WF C, March, NC
4010ES Models 4010-9423, -9428, -9501, -9502, -9503, -9504, -9521, -9522, -9523, -9524, -9527, -9528, -9529,
and -9530, Models 4010-9401, -9402, -9403, -9404, -9405, -9406, -9421, -9422, -9425, -9426, -9525 and -9526 ,
Models 4010-9401BA, -9402BA, 9501BA, 9502BA, 9503BA, 9504BA, 9421BA, 9422BA, 9425BA, 9426BA, 9521BA,
9522BA, 9523BA, 9524BA, 9525BA, 9526BA, 9527BA, 9528BA, 9529BA, and 9530BA; 4010ESS Models 4010-9601,
-9602, -9603, -9604, -9606, -9609, -9610, -9621, -9622, -9623, -9624, -9701, -9702, -9711, -9712, -9721, -9722
and -9602BA * Note: "BA" at the end of the model number designates "built in America"
L A, M, SS, WF C, March, NC
AUX, L A, M, WF C, March, NC
4100-9231, -9232, -9233, -9234, -9235, -9236, -9237, -9238, -9513, -9531, -9532, -9533, -9534
Supervising Station
4190-8403 (b) (+), -8405 (b) (+) P (RU) A, M, SS, WF DAC, MX, OT
2120 Series (c) AUX, CS (PPU), L, LS, P A, M, SS, WF, WSS C, DAC, MX, March,
(RU), P, RS (PPU) NC
1 of 4 3/17/2017 11:28 AM
UOJZ.S771 - Control Units, System http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...
AUX, LS A, M, WF C, March, NC
P (PPU) A, M, SS, WF NC
P (PPU) A, M, SS, WF NC
P (PPU) A, M, SS, WF NC
L A, M, SS, WF March, NC
AUX A, M, WF NC
L A, M, SS, WF March, NC
4100-9001 (b), 4100-9111 (b), 4100-9112(b), 4100-9113(b), 4100-9114 (b), 4100-9115(b), 4100-9116(b),
4100-9121(b), 4100-9122 (b), 4100-9211 (b), 4100-9212 (b), 4100-9213 (b), 4100-9214 (b), 4100-9222 (b),
4100-9311(b), 4100-9314 (b)
L A, M, SS, WF C, March, NC
AUX, LS A, M, WF NC
Drawer style/low silhouette rack mount controls, Model(s) 4010-9101*, 4010-9101SP*, 4010-9102*, 4010-9201*, 4010-9201SP*,
4010-9202*, 4100-8701*, 4120-8700*, 4120-8701*, 4120-8721*
2 of 4 3/17/2017 11:28 AM
UOJZ.S771 - Control Units, System http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...
Subassemblies, Model(s) 4100-7150, 4100-7158, 4100-7152, 4100-7154, 4100-7156, 4100-9833, 4100-6038 RS-232(b) master controller
replacement
L - Local System
SS - Supervisory: gate valves, water-level switches, temperature switches, carbon monoxide alarm, residential fire alarm control units, etc.
C - Coded
MX - Multiplex
P - Proprietary System
(a) - System control unit with additional emergency voice communications, supplementary tape deck with pre-recorded message and paging when
Type is Local System (L). When Type is Proprietary (PPU) and Type Signaling is Coded (C) or When Type Signaling is Digital Alarm Communicator
(DAC) - see footnote +.
(b) - Complementary Listed under DAYRC, AMCX, APOU. For Digital Alarm Communication (DAC), refer to note +.
(c) - When Type is Central Station (PPU) or Type Signaling is Digital Alarm Communicator (DAC) - see footnote +.
3 of 4 3/17/2017 11:28 AM
UOJZ.S771 - Control Units, System http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...
(d) - When Type is Proprietary (PPU) or Type Signaling is Digital Alarm Communicator (DAC) - see footnote +.
+ - Must be employed with additional specific Listed device(s) as indicated in installation instructions and wiring diagrams to provide indicated type
service. Suitable for sprinkler supervisory service.
© 2017 UL LLC
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading
manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission
from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format:
"© 2017 UL LLC".
4 of 4 3/17/2017 11:28 AM