Professional Documents
Culture Documents
Manufacturer’s profile
• Estimated company turnover during the year 2007 – more than 60 mln. EUR.
Application
SKS-4 is an universal thermal energy calculator,
which meets the requirements of EN 1434 and
OIML R75.
It can be used for calculating the amount of
consumed thermal energy in open and closed
heat supply systems, where heating agent is
water with temperatures up to 180 OC, and flow
is up to 18 200 m3/h, or in cooling systems using
water or water-glycol solution as the coolant.
The calculator is modular in design, and can be fitted with optional modules
depending on the application.
Heating calculator SKS-4
• Flexible menu setup – list of parameter values displayed on the LCD may be
configured according to the customer’s needs
• Up to 3 temperature sensors
• Tariff functions
Temperature measurement
number of measurement channels up to 3
temperature range 0 OC … 180 OC
temperature difference range 2 K … 150 K
temperature sensors Pt500, Pt1000 (EN 60751)
measurement principle 4-wire, 2-wire
cable length 2,5 … 100 m
Display resolution:
temperature 0,1 O
temperature difference 0,01 OC
Heating calculator SKS-4
Flow measurement
mains version:
mains supply 230 V AC (+10 / -15)%, 50 Hz, 2,5 VA
low mains supply 20,4 … 26,4 V AC
Environment conditions
ambient temperature 5 OC … 55 OC
ambient class Class C according to EN 1434
protection class IP65
Outline dimensions: 159 x 138 x 52 mm
Heating calculator SKS-4
Also, other types of flow sensors with pulse outputs are suitable:
Current markets
SKS-4 was carefully designed according to
specific market demands from Western
European and Eastern European markets.
www.axis.lt