Show Speaker Placement Data

Speaker Placement Data Coverage Pattern: Square

Room Width (X) (m) : 15 Recommended Speaker Quantity : 15


Room Length (Y) (m) : 27 Coverage Area per Speaker : 32 m²
Row Spacing (m) : 5.4
Column Spacing (m) : 5
Distance Wall to First Row (m) : 2.7 Minimum Needed Power Level
Distance Wall to Last Row (m) : 2.7
Distance Wall to First Column (m) : 2.5 Watts per Speaker (W) : 0.12

1 of 2 2/21/2018, 2:02 PM
Extron Ceiling Speaker Calculator Coverage Map | Extron https://www.extron.com/product/heatmap.aspx?length=600&width=3...
Distance Wall to Last Column (m) : 2.5 Recommended Tap Setting (W) : 2
Min Recommended Amp Power (W) : 37.5

Coverage Calculation Inputs Maximum Target Power Level

Room Length (m) : 27 Watts per Speaker (W) : 0.23


Room Width (m) : 15 Recommended Tap Setting (W) : 2
Speaker Height (m) : 4.30 Min Recommended Amp Power (W) : 37.5
Listener Height (m) : 1.22
Force Grid Spacing (m) : 0 Radius of Coverage
Ambient Noise (dB SPL) : 40
Desired S/N (dB) : 25 Distance at 3 dB Down (m) : 1.61
Minimum Needed Level (dB SPL) : 65 Distance at 6 dB Down (m) : 2.37
Maximum Target Level (dB SPL) : 80 Distance at 9 dB Down (m) : 3.19
Speaker : CS 1226T Plus Distance at 12 dB Down (m) : 4.57
Part # : 42-244-03
Content : Speech (7 kHz)
Edge-to-Edge Isobar (Speaker Spacing) : 9 dB (Wide)
9 dB Isobars,
Edge to Edge
Coverage Pattern : Square
Speaker Operation : 70 V

The recommended cable for distributed speakers systems with cable runs under 100’ (30M) is
Extron SPK 16, 16 AWG Speaker Cable. For runs over 100’ (30M), use SPK 14, 14 AWG Speaker Cable.