Professional Documents
Culture Documents
Space requirements
𝑨 = 𝟖. 𝟏𝒎𝟐 ≈ 𝟑𝒎 𝒙 𝟐. 𝟕𝒎
𝑨 = 𝟗𝒎𝟐 ≈ 𝟑𝒎 𝒙 𝟑𝒎
𝑨 = 𝟗 𝒎𝟐 ≈ 𝟑𝒎 𝒙 𝟑𝒎
𝒎𝒂𝒔𝒔 = 𝑩𝑫 𝒙 𝑽
𝒌𝒈
𝒎𝒂𝒔𝒔(𝒌𝒈) = 𝟓𝟕𝟔 𝒙 𝟗𝒎𝟑
𝒎𝟑
𝒎𝒂𝒔𝒔 = 𝟓𝟏𝟖𝟒𝒌𝒈
𝟏 𝒔𝒂𝒄𝒌
#𝒐𝒇 𝒔𝒂𝒄𝒌𝒔 = 𝟓𝟏𝟖𝟒𝒌𝒈 𝒙
𝟓𝟎𝒌𝒈
Lighting Requirements:
• NO. OF BULBS FOR BREEDING (Fluorescent lamp, 20W) 150 lux
𝟎. 𝟐𝟎𝟓 𝒃𝒖𝒍𝒃𝒔
= 𝟖. 𝟏 𝒎𝟐 ×
𝒎𝟐
= 𝟐 𝒃𝒖𝒍𝒃𝒔
• NO. OF BULBS FOR GROWING AND FINISHING (Fluorescent lamp, 20W) 50 lux
𝟎. 𝟎𝟔𝟖 𝒃𝒖𝒍𝒃𝒔
= 𝟗 𝒎𝟐 ×
𝒎𝟐
= 𝟏 𝒃𝒖𝒍𝒃
𝟎. 𝟎𝟐𝟕 𝒃𝒖𝒍𝒃𝒔
= 𝟗 𝒎𝟐 × = 𝟏 𝒃𝒖𝒍𝒃
𝒎𝟐
𝟎. 𝟎𝟐𝟕 𝒃𝒖𝒍𝒃𝒔
= 𝟖. 𝟏𝒎𝟐 × = 𝟏 𝒃𝒖𝒍𝒃
𝒎𝟐
# of outlets
Formula:
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝑆𝑜𝑤 𝑎𝑟𝑒𝑎 = 𝑥
20 3.28𝑓𝑡
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝑺𝒐𝒘 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2(3𝑥3.28)𝑓𝑡 + 2(2.7𝑥3.28)𝑓𝑡 1𝑚
= 𝑥
20 3.28𝑓𝑡
= 𝟏 𝒐𝒖𝒕𝒍𝒆𝒕
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒇𝒂𝒕𝒕𝒆𝒏𝒆𝒓𝒔 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒇𝒂𝒕𝒕𝒆𝒏𝒆𝒓𝒔 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2(3𝑥3.28)𝑓𝑡 + 2(3𝑥3.28)𝑓𝑡 1𝑚
= 𝑥
20 3.28𝑓𝑡
= 𝟏 𝒐𝒖𝒕𝒍𝒆𝒕
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒑𝒊𝒈𝒍𝒆𝒕𝒔 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒑𝒊𝒈𝒍𝒆𝒕𝒔 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2(3𝑥3.28)𝑓𝑡 + 2(3𝑥3.28)𝑓𝑡 1𝑚
= 𝑥
20 3.28𝑓𝑡
= 𝟏 𝒐𝒖𝒕𝒍𝒆𝒕
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒔𝒕𝒐𝒓𝒂𝒈𝒆 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒔𝒕𝒐𝒓𝒂𝒈𝒆 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2(3𝑥3.28)𝑓𝑡 + 2(2.7𝑥3.28)𝑓𝑡 1𝑚
= 𝑥
20 3.28𝑓𝑡
= 𝟏 𝒐𝒖𝒕𝒍𝒆𝒕
# of branch circuits
TDL (Total Demand Load )
Power Requirements on Growing and finishing
= # 𝒐𝒇 𝒃𝒖𝒍𝒃𝒔 𝒙 𝒘𝒂𝒕𝒕𝒂𝒈𝒆
= 𝟏 𝒙𝟐𝟎 𝒘𝒂𝒕𝒕𝒔
Power Requirements on Breeding
= # 𝒐𝒇 𝒃𝒖𝒍𝒃𝒔 𝒙 𝒘𝒂𝒕𝒕𝒂𝒈𝒆
𝟏 𝒙𝟐𝟎 𝒘𝒂𝒕𝒕𝒔
Power Requirements on Piglets area
= # 𝒐𝒇 𝒃𝒖𝒍𝒃𝒔 𝒙 𝒘𝒂𝒕𝒕𝒂𝒈𝒆
𝟏 𝒙𝟐𝟎 𝒘𝒂𝒕𝒕𝒔
Power Requirements on Storage room
= # 𝒐𝒇 𝒃𝒖𝒍𝒃𝒔 𝒙 𝒘𝒂𝒕𝒕𝒂𝒈𝒆
𝟐 𝒙𝟒𝟎 𝒘𝒂𝒕𝒕𝒔
Power Requirements on walkways area
= # 𝒐𝒇 𝒃𝒖𝒍𝒃𝒔 𝒙 𝒘𝒂𝒕𝒕𝒂𝒈𝒆
𝟐 𝒙𝟒𝟎 𝒘𝒂𝒕𝒕𝒔
Branch Circuit
# 𝒐𝒇 𝒍𝒊𝒈𝒉𝒕𝒔+# 𝒐𝒇 𝒐𝒖𝒕𝒍𝒆𝒕𝒔
=
𝟏𝟐
𝟕+𝟒
=
𝟏𝟐
Formulas :
𝑨 = 𝟖. 𝟏𝒎𝟐 ≈ 𝟑𝒎 𝒙 𝟐. 𝟕𝒎
𝑨 = 𝟗𝒎𝟐 ≈ 𝟑𝒎 𝒙 𝟑𝒎
𝑨 = 𝟗 𝒎𝟐 ≈ 𝟑𝒎 𝒙 𝟑𝒎
𝒎𝒂𝒔𝒔 = 𝑩𝑫 𝒙 𝑽
𝒌𝒈
𝒎𝒂𝒔𝒔(𝒌𝒈) = 𝟓𝟕𝟔 𝒙 𝟗𝒎𝟑
𝒎𝟑
𝒎𝒂𝒔𝒔 = 𝟓𝟏𝟖𝟒𝒌𝒈
𝟏 𝒔𝒂𝒄𝒌
#𝒐𝒇 𝒔𝒂𝒄𝒌𝒔 = 𝟓𝟏𝟖𝟒𝒌𝒈 𝒙
𝟓𝟎𝒌𝒈
= 𝟐 𝒃𝒖𝒍𝒃𝒔
• NO. OF BULBS FOR GROWING AND FINISHING (Fluorescent lamp, 20W) 50 lux
𝟎.𝟎𝟔𝟖 𝒃𝒖𝒍𝒃𝒔
= 𝟗 𝒎𝟐 × 𝒎𝟐
= 𝟏 𝒃𝒖𝒍𝒃
𝟎. 𝟎𝟐𝟕 𝒃𝒖𝒍𝒃𝒔
= 𝟗 𝒎𝟐 × = 𝟏 𝒃𝒖𝒍𝒃
𝒎𝟐
𝟎. 𝟏𝟎𝟕 𝒃𝒖𝒍𝒃𝒔
= 𝟏𝟎. 𝟒𝟒𝒎𝟐 × = 𝟐 𝒃𝒖𝒍𝒃
𝒎𝟐
Number of outlets
Formula:
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝑆𝑜𝑤 𝑎𝑟𝑒𝑎 = 𝑥
20 3.28𝑓𝑡
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝑺𝒐𝒘 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2(3𝑥3.28)𝑓𝑡 + 2(2.7𝑥3.28)𝑓𝑡 1𝑚
= 𝑥
20 3.28𝑓𝑡
= 𝟏 𝒐𝒖𝒕𝒍𝒆𝒕
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒇𝒂𝒕𝒕𝒆𝒏𝒆𝒓𝒔 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒇𝒂𝒕𝒕𝒆𝒏𝒆𝒓𝒔 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2(3𝑥3.28)𝑓𝑡 + 2(3𝑥3.28)𝑓𝑡 1𝑚
= 𝑥
20 3.28𝑓𝑡
= 𝟏 𝒐𝒖𝒕𝒍𝒆𝒕
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒑𝒊𝒈𝒍𝒆𝒕𝒔 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒑𝒊𝒈𝒍𝒆𝒕𝒔 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2(3𝑥3.28)𝑓𝑡 + 2(3𝑥3.28)𝑓𝑡 1𝑚
= 𝑥
20 3.28𝑓𝑡
= 𝟏 𝒐𝒖𝒕𝒍𝒆𝒕
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒔𝒕𝒐𝒓𝒂𝒈𝒆 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2𝐿 + 2𝑊 1𝑚
# 𝑜𝑓 𝑜𝑢𝑡𝑙𝑒𝑡𝑠 𝑓𝑜𝑟 𝒔𝒕𝒐𝒓𝒂𝒈𝒆 𝒂𝒓𝒆𝒂 = 𝑥
20 3.28𝑓𝑡
2(3𝑥3.28)𝑓𝑡 + 2(2.7𝑥3.28)𝑓𝑡 1𝑚
= 𝑥
20 3.28𝑓𝑡
= 𝟏 𝒐𝒖𝒕𝒍𝒆𝒕
# 𝒐𝒇 𝒍𝒊𝒈𝒉𝒕𝒔 𝟕
= = ≈ 1 branch circuit
𝟏𝟎 𝟏𝟎
# 𝒐𝒇 𝒐𝒖𝒕𝒍𝒆𝒕𝒔 𝟒
= = ≈ 1 branch circuit
𝟏𝟐 𝟏𝟐
TABLE 1 Space Requirements
1 𝑠𝑎𝑐𝑘
No. of Sacks = mass x 1 sack/ 50kg 5184𝑘𝑔 𝑥 = 103.68 ≈ 𝟏𝟎𝟒 𝒔𝒂𝒄𝒌𝒔
50𝑘𝑔
Computation Number of
List of Area Area (sq. ft.) 𝟐𝒍+𝟐𝒘
(LxW) outlet = 𝟏𝟐
Sow 9.84ft. x 8.86ft. 87.14 1