You are on page 1of 687

SUMMERY

NAME OF WORK - CONSTRUCTION OF PROPOSED DR. RAM MANOHAR LOHIA RAJYA PRASHASAN EVAM PRABANDHAN ACADEMY AT CHAK GANJARIA, SULTANPUR ROAD, LUCKNOW ( U. P )

S.NO PARTICULARS ESTIMATED COST IN INR PERCENTAGE TOTAL AMOUNT AFTER ADDITION OR DEDUCTION OF
QUOTED BY THE OFFERED PERCENTAGE
BIDDER
.+ve OR . -ve QUOTED AMOUNT IN QUOTED AMOUNT IN
FIGURES IN INR WORDS

1 CIVIL & FINISHING WORKS OF BUILDINGS 1,662,309,464

2 SANITARY & PLUMBING WORKS I/C STP, PUMPS, EQUIPMENTS, EXTERNAL SEWERAGE WORKS 174,673,296

3 CIVIL WORKS FOR PLUMBING & FIRE FIGHTING 386,142

4 FIRE FIGHTING WORKS & PUMPS, EQUIPMENTS 46,982,645

5 ELECTRICAL WORKS 355,454,229

6 HVAC WORKS 220,621,992

7 ADDITIONAL WORKS LIKE BOOM BARRIERS, GAS SUPPRESSION SYSTEM FOR SERVER, RODENT CONTROL 4,743,350

SPECILISED WORKS & EQUIPMENTS

8 UPS SYSTEM & INVERTERS 4,310,765

9 SURVILLANCE & SECURITY 16,666,545

10 LIFTS 19 NOS 40,460,580

11 DISTRIBUTION TRANSFORMERS - 3NO 7,500,000

12 SILENT TYPE D.G. SET 1500 KVA -04NO., 750 KVA-01NO. 48,920,000

13 BUILDING MANAGEMENT SYSTEMS WORKS 21,761,374

14 SOLAR HOT WATER GENERATION SYSTEM (292690 + 483000 +405570) 1,181,260

GRAND TOTAL I/C ALL TAXES I.E. WORK CONTRACT TAX, SERVICE TAX(1 TO 14) 2,605,971,643

SIGNATURE OF UPRNN. LTD. SIGNATURE OF BIDDER WITH STAMP

1
PROJECT - CONSTRUCTION OF PROPOSED DR. RAM MANOHAR LOHIA RAJYA PRASHASAN EVAM
PRABANDHAN ACADEMY AT CHAK GANJARIA, SULTANPUR ROAD, LUCKNOW ( U. P )
1 GRAND SUMMARY OF CIVIL & FINISHING WORKS OF BUILDINGS

S.NO HEAD AMOUNT IN INR

1.01 Academic & administration Block with basement ( A1,A2,A3,A4) 841,442,961

1.02 Hostel H1 & H2 342,072,404

1.03 Residential Type 1 & 2 (BLOCK R3) 174,563,736

1.04 Residential Type 3 &4 (BLOCK R1&R2) 304,230,363

GRAND TOTAL I/C ALL TAXES I.E. WORK CONTRACT TAX, SERVICE TAX 1,662,309,464

SUMMARY OF COST OF CIVIL WORKS- ACADEMIC AND ADMINISTRATIVE BLOCK WITH BASEMENT (A1, A2, A3 & A4)
SUB HEAD NAME OF SUBHEAD ESTIMATED
NO AMOUNT IN INR

SH-1 EARTH WORK 4,986,870

SH-2 PILING WORKS 45,223,864

SH-3 ANTITERMITE TREATMENT 1,480,891

SH-4 PLAIN CEMENT CONCRETE WORK 21,630,022

SH-5 REINFORCED CEMENT CONCRETE WORK 160,110,005

SH-6 FORM WORK 51,412,642

SH-7 STEEL REINFORCEMENT WORK 190,351,002

SH-8 BRICK WORK 24,620,999

SH-9 WATER-PROOFING OF RAFT, RETAINING WALL, DECK SLAB, ROOFS, INTERNAL 51,816,765
WET AREAS

SH-10 INSULATION - OVERHEAD & UNDERDECK 5,280,568

SH-11 PLASTERING - INTERNAL AND EXTERNAL 32,729,280

1 (A)
1
SH-12 STEEL & STRUCTURAL STEEL WORKS 2,443,329

SH-13 EXTERNAL FAÇADE WORK - ALUMINIUM, GLASS , GLASS DOORS 81,048,605

SH-14 WOOD WORK - DOORS, PARTITIONS & PANELING 36,121,844

SH-15 FLOORING, SKIRTING & DADO WORK 104,714,503

SH-16 FALSE CEILING WORKS 33,492,861

SH-17 WALL FINISHES - INTERNAL & EXTERNAL 7,510,180

SH-18 ALUMINIUM WORK FOR DOOR, WINDOWS 5,536,051

SH-19 FIRE DOORS & ACCESSORIES 8,268,459

SH-20 STAINLESS STEEL & GLASS RAILING WORKS 4,748,417

SH-21 HARDWARE FOR DOORS 5,294,520

SH-22 EXTERNAL FAÇADE - GRC SCREENS, ALUMINIUM LOUVERS 732,105

SH-23 MISCELLANEOUS ITEMS 4,115,900

SH-24 MODULAR WATER CLOSET CUBICLES 2,059,750

ESTIMATED COST 885,729,432

LESS 5% FOR UPRNN WORKING (44,286,472)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 841,442,961

2
BILL OF QUANTITIES - CIVIL AND FINISHING WORKS-ACADEMIC AND ADMIN.

S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

1.00 SH-1 EARTH WORK


1.01 CPWD 2.1.1 Earth work in surface excavation not exceeding 30 cm in depth but 100 sqm 131.19 5,044.15 661,742
DSR 2014 exceeding 1.5 m in width as well as 10 sqm on plan including disposal of
excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be levelled
and neatly dressed in all kinds of soil

1.02 UPPWD 251(4.1.1) Excavation in foundations in ordinary soil (loam, clay and sand) including lift cum 30,015.55 92.00 2,761,431
SOR 2014 upto 1.5m. (5fts.) and lead upto 30m. (100fts) and including filling, watering
and ramming of excavated earth in to the trenches and into the space b/w
the building and sides of foundation trenches or in to the plinth and removal
and disposal of surplus earth as directed by the engineer-in-charges up to a
distance of 30m. (100 fts) from the foundation trenches.

1.03 UPPWD 254(4.3) Add to item 251 for every additional 30m. (100 fts.) lead or part of 30m. (100 Cum. 9,803.00 13.00 127,439
SOR 2014 fts) or for every additional 1.5m. (5fts) lift or part of 1.5m (5 fts).

1.04 CPWD 2.25 Filling available excavated earth (excluding rock) in trenches, sides of cum 4,300.00 112.40 483,320
DSR 2014 foundations , plinth, etc. in layers not exceeding 20 cm. in depth,
consolidating each deposited layer by ramming and watering i/c lead upto
50 M and lift upto 1.5M. (Measurement after complete consolidation will be
considered for payment).

1.05 UPPWD 255+deriv Supplying and filling in plinth with local fine sand from river under floors cum 1,311.90 726.38 952,938
SOR 2014 ed including watering, ramming, consolidating and dressing complete

Total of Subhead-1 - 4,986,870

3
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.00 SH-2 PILING WORKS
2.01 CPWD 20.2A.2 Boring, providing and installing 750 mm dia piles bored cast-in-situ reinforced metre 6,426.00 5,215.40 33,514,160
DSR 2014 cement concrete piles of grade M-25 of specified diameter and length
below the pile cap, to carry a safe working load not less than specified
excluding the cost of steel reinforcement but including the cost of
appropriate length for setting out and removal of same and the length of
the pile to be embedded in the pile cap etc. by crawler mounted,
telescopic boom hydraulic piling rig all complete , including removal of
excavated earth with all lifts and leads (Length of pile for payment shall be
measured upto bottom of pile cap). Tuck mounted rotary / TMR / tube well
boring machine shall not be used.

2.02 CPWD 20.2.3 Boring, providing and installing 450 mm dia piles bored cast-in-situ reinforced metre 4,000.00 1,665.35 6,661,400
DSR 2014 cement concrete piles of grade M-25 of specified diameter and length
below the pile cap, to carry a safe working load not less than specified
excluding the cost of steel reinforcement but including the cost of
appropriate length for setting out and removal of same and the length of
the pile to be embedded in the pile cap etc. by percussion drilling using
direct mud circulation ( DMC) or bailer and chisel technique by tripod and
mechanical winch machine all complete , including removal of excavated
earth with all lifts and leads (Length of pile for payment shall be measured
upto bottom of pile cap). Tuck mounted rotary / TMR / tube well boring
machine shall not be used.
2.03 CPWD 20.3.1 Boring, Providing and installing cast in situ single under reamed piles of metre 1,617.00 2,123.15 3,433,134
DSR 2014 300mm diameter and length below pile cap in M-25 cement concrete, to
carry a safe working load not less than specified, excluding the cost of steel
reinforcement but including the cost of boring with Bentonite solution and
the length of the pile to be embedded in pile cap etc. all complete. (Length
of pile for payment shall be measured upto to the bottom of pile cap) :

2.04 CPWD 20.6.1.2 Carrying out routine Vertical load testing on single pile upto 50 tonne in per test 6.00 17,422.50 104,535
DSR 2014 accordance with IS 2911 (Part IV) including installation of loading platform
by Kentledge method and preparation of pile head or construction of test
cap and dismantling of test cap after tests etc. complete as per
specifications and the direction of engineer in charge ( Test load 1.5 times
the safe capacity)

4
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.05 CPWD 20.6.2.1 Carrying out Initial Vertical load testing on single pile above 50 tonne to 100 Per test 6.00 46,808.45 280,851
DSR 2014 tonne in accordance with IS 2911 (Part IV) including installation of loading
platform by Kentledge method and preparation of pile head or construction
of test cap and dismantling of test cap after tests etc. complete as per
specifications and the direction of engineer in charge. ( test load 2.5 times
the safe capacity)

2.06 CPWD 20.6.2.2 Carrying out routine Vertical load testing on single pile above 50 tonne to per test 5.00 26,714.50 133,573
DSR 2014 100 tonne in accordance with IS 2911 (Part IV) including installation of
loading platform by kentledge method and preparation of pile head or
construction of test cap and dismantling of test cap after test etc. complete
as per specifications and the direction of engineer in charge. ( Test load 1.5
times the safe capacity)

2.07 CPWD 20.9 Integrity testing of pile using Low Strain/Sonic Integrity Test/Sonic Echo Test Per test 176.00 745.50 131,208
DSR 2014 method in accordance with IS 14893 including surface preparation of pile
top by removing mud, dust & chipping lean concrete lumps etc. and use of
computerized equipment and high skill trained personal for conducting the
test & submission of results, all complete as per direction of engineer-in-
charge.

2.08 CPWD derived Dismantling / Breaking top portion of concrete piles up to pile cut off level cum 741.00 1,302.30 965,004
DSR 2014 from 15.3 and removing rubbish/spoil up to a lead of 50m with all lifts, cleaning top
portion of pile cleaning reinforcement exposed due to breaking of pile top,
bending pile reinforcement into pile cap as per drawing and instruction of
engineer.

Total of Subhead-2 45,223,864

5
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.00 SH 3 ANTITERMITE TREATMENT -

3.01 CPWD 2.34.1 Supplying chemical emulsion in sealed containers including delivery as litre 1,987.00 168.83 335,465
DSR 2014 specified - chloryphos / Lindane emulsifiable concentrate of 20%
3.02 CPWD derived Diluting and injection chemical emulsion (to be supplied free of cost at site Sqm 9,934.31 115.30 1,145,426
DSR 2014 '2.35.1+ of work) for pre-constructional. Anti termite treatment and creating a
2.35.2+ continuous chemical barrier as per IS : 6313 part II 1981 under and all-round
2.35.3 the column pits, wall trenches, basement excavation, top surface of plinth
filling, junction of wall and floor along the external perimeter of building,
expansion joints, over the top surface of consolidated earth on which apron
is to be laid, surrounding of pipes and conduits etc., complete as
specifications (plinth area of the building at ground floor only shall be
measured for payment) Chlorpyriphos Emulsifiable concentrate 20% with 1%
concentration.
Total of Subhead-3 - 1,480,891

4.00 SH-4 PLAIN CEMENT CONCRETE WORK -


4.01 CPWD 4.1.5 Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse cum 942.39 4,834.30 4,555,796
DSR 2014 sand : 6 graded stone aggregate 20mm nominal size) excluding cost of
centering and shuttering - All works upto plinth level.
4.02 CPWD 4.20 Providing and laying in position ready mix plain cement concrete, with -
DSR 2014 cement content as per approved design mix and manufacture in fully
automatic batching plant and transported to site of work in transit mixer for
all leads, having continuous agitated mixer, manufactured as per mix design
of specific grade for plain cement concrete work, including pumping of RMC
from transit mixer to site of laying i/c curing excluding cost of centering and
shuttering and finishing i/c cost of curing, admixtures in recommended
portion as per IS 9103 to accelerate / retard setting of concrete , improve
workability without impairing strength and durability as per the directions of
engineer in charge.

Note : (1) Excess or less cement used in this item is payable / recoverable -
separately.
4.2.1 CPWD 4.20.1 All works upto plinth level -
DSR 2014
4.2.1.1 CPWD 4.20.1.1 M15 grade plain cement concrete ( cement content considered @ 240 kg cum 1,049.52 5,086.95 5,338,856
DSR 2014 per cum)
4.2.1.2 CPWD 4.20.1.2 M10 grade plain cement concrete ( cement content considered @ 220 kg cum 1,631.30 4,964.75 8,098,997
DSR 2014 per cum)

6
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
4.2.2 CPWD 4.20.2 All works above plinth level and upto floor V level -
DSR 2014
4.2.2.1 CPWD 4.20.2.1 M15 grade plain cement concrete ( cement content considered @ 240 kg cum 15.00 5,475.30 82,130
DSR 2014 per cum)
4.2.2.2 CPWD 4.20.2.2 M10 grade plain cement concrete ( cement content considered @ 220 kg cum 663.96 5,353.10 3,554,244
DSR 2014 per cum)
Total of Subhead-4 - 21,630,022

5.00 SH-5 REINFORCED CEMENT CONCRETE WORK


RMC
5.01 CPWD 5.40 Providing and laying in position ready mix M25 grade concrete for reinforced
DSR 2014 cement concrete work, using fly ash and cement content as per approved
design mix and manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having continuous
agitated mixer, manufactured as per mix design of specific grade for plain
cement concrete work, including pumping of RMC from transit mixer to site
of laying i/c curing excluding cost of centering and shuttering and finishing
i/c cost of curing, admixtures in recommended portion as per IS9103 to
accelerate / retard setting of concrete , improve workability without
impairing strength and durability as per the directions of engineer in charge.
cement content considered in this item is @ 330 kg per cum of concrete.
Note : (1) Excess or less cement used as per design mix is payable /
recoverable separately. 2. Fly ash confirming to grade I of IS 3812 ( Part 1)
only be used as part replacement of OPC as per IS 456. Uniform blending
with cement is to ensured in accordance with clause 5.2 and 5.2.1 of IS 456-
2000 in the items of B.M.C and R.M.C.
5.1.1 CPWD 5.40.1 All works upto plinth level cum 12,056.40 6,561.20 79,104,452
DSR 2014
5.1.2 CPWD 5.40.2 All works above plinth level and upto floor V level cum 10,922.10 7,279.60 79,508,519
DSR 2014
5.02 CPWD 5.34.1 Extra for providing richer mixes at all floor levels for providing M-30 grade cum 1,374.40 76.50 105,142
DSR 2014 concrete in place of M-25 grade B.M.C./R.M.C. ( cement content
considered in M30 @ 340kg. per cum of concrete)
5.03 CPWD 5.34.2 Extra for providing richer mixes at all floor levels for providing M-35 grade cum 3,587.57 152.95 548,719
DSR 2014 concrete in place of M-25 grade B.M.C./R.M.C. ( cement content
considered in M35 @ 350kg. per cum of concrete)

7
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
5.04 CPWD 5.34.3 Extra for providing richer mixes at all floor levels for providing M-40 grade cum 1,565.30 229.45 359,158
DSR 2014 concrete in place of M-25 grade B.M.C./R.M.C. ( cement content
considered in M40 @ 360kg. per cum of concrete)
5.05 CPWD 5.38 Extra for R.C.C. / B.M.C. / R.M.C. work above floor V level for each four floors cum 692.11 174.20 120,566
DSR 2014 or part there of.
5.06 CPWD 5.13 Providing, hoisting and fixing upto floor five level pre cast reinforced cum 22.69 8,797.80 199,622
DSR 2014 concrete work in small lintels not exceeding 1.5 M clear span including cost
of required centering & shuttering but excluding the cost of
reinforcement1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 20mm
nominal size)
5.07 CPWD 5.15 Providing, hoisting and fixing upto floor five level pre cast reinforced cum 20.00 8,191.40 163,828
DSR 2014 concrete in lintels, beams and bressumers including setting in cement mortar
1:3 ( 1 cement : 3 coarse sand ) cost of required centering , shuttering
complete but excluding the cost of reinforcement with 1:2:4 ( 1 cement : 2
coarse sand : 4 stone aggregate 20mm nominal size) .

Total of Subhead-5 - 160,110,005

6.00 SH-6 FORM WORK -


6.01 CPWD 5.9.1 Centering and shuttering for foundations, footings, bases of columns etc. for sqm 360.00 196.45 70,722
DSR 2014 mass concrete including strutting, propping, oiling, etc. removal of form work.

6.02 CPWD 5.9.2 Centering and shuttering for walls ( any thickness) including attached sqm 14,205.40 360.80 5,125,308
DSR 2014 pilasters, buttresses, plinth and string courses including strutting, propping,
oiling, etc. removal of form work.
6.03 CPWD 5.9.3 Centering and shuttering for suspended floors, roofs, landings, balconies and sqm 37,239.00 401.65 14,957,044
DSR 2014 access platform including strutting, propping, oiling, etc. removal of form
work.
6.04 CPWD 5.9.5 Centering and shuttering for lintels, beams, plinth beams, girders, bressumers sqm 15,959.58 332.15 5,300,974
DSR 2014 and cantilevers including strutting, propping, oiling, etc. removal of form
work.
6.05 CPWD 5.9.6 Centering and shuttering for columns, pillars, piers, abutments, posts and sqm 47,274.10 453.35 21,431,713
DSR 2014 struts including strutting, propping, oiling, etc. removal of form work.

6.06 CPWD 5.9.16.1 Centering and shuttering for edges of slabs and breaks in floors and walls Metre 200.00 116.40 23,280
DSR 2014 upto 20cm width including strutting, propping, oiling, etc. removal of form
work.

8
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.07 CPWD 5.11.1 Extra for additional height in centering, shuttering wherever required for sqm 15,167.00 159.05 2,412,311
DSR 2014 suspended floors, roofs, landings, beams and balconies ( plan area to be
measured ) with adequate bracing, propping etc. including cost of de-
shuttering and de-centering at all levels, over a height of 3.5m, for additional
height of 1 Metre or part thereof ( plan area to be measured )

6.08 CPWD 5.9.14.b Extra for shuttering in circular Columns sqm 23,637.00 87.07 2,058,074
DSR 2014
6.09 CPWD 5.9.5.b Extra for shuttering in curved beams (20% of beam rate) sqm 500.00 66.43 33,215
DSR 2015
Total of Subhead-6 - 51,412,642

7.00 SH-7 STEEL REINFORCEMENT WORK -


7.01 UPPWD Derived Providing and fixing Thermo-mechanically treated MS bars reinforcement for kg 1,329,500.00 68.90 91,602,550
SOR 2014 from 504 R.C.C. work including straightening, cutting, bending, placing in position and
binding complete upto plinth level. - Fe 500

7.02 UPPWD Derived Providing and fixing Thermo-mechanically treated MS bars reinforcement for kg 1,373,107.00 68.90 94,607,072
SOR 2014 from 504 R.C.C. work including straightening, cutting, bending, placing in position and
binding complete above plinth level. - - Fe 500

7.03 NS AR-04 Design, supply & execution of UPS Post Tensioning system (pre stressing works) MT 24.12 171,699.00 4,141,380
including providing of High Tensile Steel, Post Tensioning head & dead
Anchorages, GI Ducts, Wedges draw in 6mm with Consumables &
installation/fixing of 0.5" 7 wire low relaxation non-coated bare Stress, Ducts,
Anchor Blocks, Tendon Support Bars, wedges etc. grouting of tendons i/c
supply of grouting equipment, in Post Tensioning Beams/Slab as per
specification complete. Shop Drawings along with Design Report &
calculations for Post Tensioning members shall be submitted to Structural
Consultant for approval. Rates are applicable for all Heights & levels. The
design shall be as per IS: 1343-1980, IS: 456, BS:8110. The structural use of
concrete 1991 & TR43. All lateral loads are resisted by shear & core walls. The
shop drawings preparation included in cost. The equipment required for
execution will be brought by contractor & cost is included item. The cement
& admixture required for grout is included in rate.
Total of Subhead-7 - 190,351,002

9
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.00 SH-8 BRICK WORK
8.01 UPPWD 303 First class brick work in 1:6 cement and fine sand of 1.25 fineness modulus cum 448.42 4,850.00 2,174,837
SOR 2014 mortar in foundation and plinth including supply of all materials, labour and
tools and plants etc. required for proper completion of the work.

8.02 CPWD 6.5 Extra for brick work / AAC block masonry / tile brick masonry in superstructure cum 257.47 289.05 74,422
DSR 2014 above floor V level for each four floors or part thereof by mechanical means
by lifting material using mobile crane

8.03 CPWD 6.14 Extra for half brick masonry in superstructure above floor V level for every four sqm 484.34 25.60 12,399
DSR 2014 floors or part thereof by mechanical means by lifting material using mobile
crane.
8.04 CPWD 6.15 Extra for providing and placing in position 2 nos. 6mm dia M.S. bars at every sqm 2,411.91 69.50 167,628
DSR 2014 third course of half brick masonry with FPS bricks in superstructure above
plinth level up to floor V level
8.05 CPWD 6.38 Providing and laying autoclaved aerated cement blocks masonry with 100 cum 3,474.54 6,386.95 22,191,713
DSR 2014 mm thick AAC blocks in super structure above plinth level up to floor V level
in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing
and placing in position 2 Nos 6 mm dia M.S. bars at every third course of
masonry work.

Total of Subhead-8 - 24,620,999

9.00 SH-9 WATER-PROOFING OF RAFT, RETAINING WALL, DECK SLAB, ROOFS, INTERNAL WET AREAS

BASEMENT & UNDERGROUND STRUCTURES WATER-PROOFING

RAFT & VERTICAL SURFACES

Waterproofing of Raft:

10
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.01 NS AR-05 Supplying and installing membrane waterproofing treatment for Raft Slab , sqm 16,488.80 1,987.21 32,766,708
1.2mm thick fully bonded HDPE sheet membrane "Preprufe 300 R " or
equivalent approved make before casting of base RCC slab. The pre-
applied, fully bonded HDPE sheet membrane gets bonded to the
underneath of the poured concrete used as base/ raft slab. The fully bonded
HDPE sheet membrane shall consist of a thick HDPE film, a highly aggressive
pressure sensitive adhesive and weather resisting coating which bonds
integrally to poured concrete of base slab. The membrane shall be BBA
certified and conforms to basement waterproofing protection to grades 2, 3
as defined in BS 8102:2009. The fully bonded HDPE sheet waterproofing
membrane shall have following minimum properties : 1) Resist hydrostatic
pressure of upto 70 m head of water as per ASTM D5385; 2) Puncture
Resistance of 990 N 3) Adhesion to concrete of 2.88 N/mm. The fully bonded
HDPE sheet membrane, shall be installed with standard 75mm side edge laps
and 75mm end laps taped with Tape HC, a double side coated adhesive
tape over the entire area and turned up on to a vertical timber. The
membrane shall be laid over the concrete blinding having smooth dried
surface including necessary removal of release liner while applying,
necessary overlaps between the membranes and fixing overlaps by Tape,
firm rolling onto the surface to get a tight seal, etc. All systems to be installed
as per approved manufacturer's recommendations, etc. complete with all
lead and lift for all materials and labour and as directed by Engineer in-
charge. Refer drawing.

Waterproofing treatment to Construction joints in walls / floors -

9.02 CPWD 22.4.1 providing and placing in position suitable PVC water stops Serrated with Metre 587.36 490.20 287,924
DSR 2014 central bulb ( 225 mm wide, 8-11 mm thick) conforming to IS : 12200 of Deep
Jyoti or equivalent for construction / expansion joints between two RCC
members and fixed to the reinforcement with binding wire before pouring
concrete etc. complete.

11
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Waterproofing of Retaining Wall: -
9.03 NS AR-08 Supplying and Installing self adhesive, cold applied , flexible 1.5mm thick sqm 6,738.65 1,284.48 8,655,661
waterproofing membrane " Bituthene 8000" or equivalent approved make
comprising of a self adhesive rubberized asphalt with cross laminated HDPE
film with a unique solar reflective film on top surface . The membrane shall
have pre-marked overlaps of 50mm and shall be applied on the uniform
concrete surface. The self adhesive membrane shall be BBA certified and
confirm to all grades of BS 8102:2009 and shall have following minimum
properties : (i)  Puncture resistance of 290N (ii) Resistance to Hydrostatic
head of 70m (ASTM D 5385) (iii) Should be resistant to Sulphates, Nitrates and
salt in soil. For membrane termination: Make 25mm x 25mm chase/rebate on
the vertical wall for termination of the membrane. The chase/rebate shall be
adequately sealed with approved material. All systems to be installed as per
approved manufacturer's recommendations, etc. complete with all lead
and lift for all materials and labour and as directed by Engineer in-charge as
per drawings. system shall be guaranteed for 10 years on Rs 100/- stamp
paper.

9.04 NS AR-09 Providing and fixing HDPE protection board on vertical surfaces with sqm 6,738.65 230.00 1,549,890
adhesives i/c cost of overlaps @ 10% as protection of waterproofing.

SUNKEN AREA WATERPROOFING - -

9.05 CPWD 22.5 Providing and laying water proofing treatment in sunken portion of WCs, sqm 1,229.46 283.10 348,060
DSR 2014 bathroom etc., by applying cement slurry mixed with water proofing cement
compound consisting of applying : (a) Ist layer of slurry of cement @ 0.488
kg/sqm mixed with water proofing compound @0.253 kg/per sqm. This layer
will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @
0.242 kg/sqm mixed with water proofing compound @0.126 kg/sqm. This
layer will be allowed to air cure for 4 hours followed with water curing for 48
hours. The rate includes preparation of surface, treatment and sealing of all
joints, corners, junction of pipes and masonry with polymer mixed slurry.

9.06 CPWD 13.6.1 20 mm cement plaster of mix Cement mortar 1:4. to protect the sqm 1,229.46 242.05 297,591
DSR 2014 waterproofing

12
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ROOF WATERPROOFING -

9.07 CPWD 22.20 Providing and laying APP (Atactic Polypropylene Polymer) modified sqm 995.55 425.35 423,457
DSR 2014 prefabricated five layer, 3mm thick water proofing membrane, black finished
reinforced with non-woven polyester matt consisting of a coat bitumen
primer for bitumen membrane @ 0.40ltr/sq.mt by the same membrane
manufactured of density @25°C, 0.87-0.89 kg/litre and viscosity 70-160 cps.
over the primer coat the layer of membrane shall be laid using burtan torch
and sealing all joints etc. and preparing the surfaces complete. the vital
physical and chemical parameters of the membrane shall be as under:-
Joint strength in longitudinal and transverse direction at 23°C as 650/450
N/5cm. Tear strength in longitudinal and transverse direction as 300/250N.
Softening point of membrane not less then 150° C. cold flexibility shall be
upto -2°C when tested in accordance with ASTM, D_5147. The laying of
membrane shall be got done through the authorized applicator of the
manufacturer of membrane.

9.08 NS AR-14 Providing and fixing aluminum flashing , wherever required for termination of Metre 280.32 495.00 138,758
Bituthene membrane at all locations . Item shall include rates for membrane
termination on the Vertical parapet wall at height as specified in drawings
for termination of the membrane.
Waterproofing Treatment for Landscaping Decks and Landscape Roofs -

9.09 CPWD 22.19 Providing and laying APP (Atactic Polypropylene Polymer) modified sqm 10,325.69 407.50 4,207,719
DSR 2014 prefabricated five layer, 3mm thick water proofing membrane, black finished
reinforced with glass fibre matt consisting of a coat of bitumen primer for
bitumen membrane @ 0.40ltr/sq.mt by the same membrane manufactured
of density @25°C, 0.87-0.89 kg/litre and viscosity 70-160 cps. Over the primer
coat the layer of membrane shall be laid using Butane torch and sealing all
joints etc. and preparing the surfaces complete. The vital physical and
chemical parameters of the membrane shall be - Joint strength in
longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength
in longitudinal and transverse direction as 60/80N. Softening point of
membrane not less then 150° C. cold flexibility shall be upto -2°C when tested
in accordance with ASTM, D_5147. The laying of membrane shall be got
done through the authorized applicator of the manufacturer of membrane.

13
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.10 CPWD 22.21 Extra for covering top of membrane with Geotextile, 120gsm non Woven, sqm 10,325.69 74.85 772,878
DSR 2014 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with
intermitted touch by heating the membrane by Butane torch as per
manufacturers recommendation [ for the item No. 22.18 to 22.20 ]

Protection on Terrace Waterproofing -


9.11 CPWD 4.20.2.1 Providing and laying in position ready mix plain cement concrete M15 cum 313.52 6,540.90 2,050,703
DSR 2014 GRADE , with cement content as per approved design mix and manufacture
in fully automatic batching plant and transported to site of work in transit
mixer for all leads, having continuous agitated mixer, manufactured as per
mix design of specific grade for plain cement concrete work, including
pumping of RMC from transit mixer to site of laying i/c curing excluding cost
of centering and shuttering and finishing i/c cost of curing, admixtures in
recommended portion as per IS 9103 to accelerate / retard setting of
concrete , improve workability without impairing strength and durability as
per the directions of engineer in charge. MINIMUM CEMENT 240 all work
above plinth level upto level 5.

9.12 CPWD 12.21 Providing gola 75mm x75mm in plain cement concrete 1:2:4 ( 1 cement :2 Metre 280.32 143.10 40,114
DSR 2014 coarse sand :4 stone aggregate 10 mm and down gauge ) I/c finishing with
cement mortar 1:3 as per standard design. In 75x75 mm deep chase

9.13 CPWD 22.14.1 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cum 49.78 5,570.55 277,302
DSR 2014 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size )

Total of Subhead-9 - 51,816,765

10.00 SH10 INSULATION - OVERHEAD & UNDERDECK


10.01 CPWD 12.56 Providing and laying roof insulation with 40 mm thick impervious sprayed, sqm 936.60 1,167.20 1,093,200
DSR 2014 closed cell free Rigid Polyurethane foam over deck insulation conforming to
IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of
polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene
sheet over PUF spray and providing a wearing course of 40 mm thick cement
screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal
size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding
with 24 G wire netting and sealing the joints with polymerized mastic, all
complete as per direction of Engineer-in-Charge

14
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
10.02 CPWD 12.34 Providing and fixing thermal insulation of ceiling (under deck insulation) with sqm 8,444.16 481.65 4,067,130
DSR 2014 Resin Bonded Fibre glass wool conforming to IS:8193 density 24kg/cum ,
50mm thick ,wrapped in 200 G Virgin Polythene bags fixed to ceiling with
metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mmx24g wire
and mesh, for top most ceiling of building.

10.03 CPWD 12.35 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool sqm 500.16 240.40 120,238
DSR 2014 conforming to IS:8193 density 16kg/cum , 50mm thick ,wrapped in 200 G
Virgin Polythene bags placed over existing false ceiling and held in position
by criss - crossing GI wire.

Total of Subhead-10 - 5,280,568

11.00 SH-11 PLASTERING - INTERNAL AND EXTERNAL


Wall plaster
11.01 UPPWD 586 12 mm thick plaster with cement mortar in proportion of 1:6 cement & fine sqm 18,152.52 109.00 1,978,625
SOR 2014 sand of 1.25 F.M.

11.02 CPWD 13.5.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:6 sqm 25,763.78 183.45 4,726,365
DSR 2014 ( 1 cement:6 coarse sand )

11.03 CPWD 13.5.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 sqm 4,515.57 183.45 828,381
DSR 2014 ( 1 cement:4 coarse sand ) in internal walls of service shafts
Ceiling plaster - -
11.04 UPPWD 584+587 12mm cement plaster to ceiling of cement mortar mix 1:4 (1 cement : 4 fine sqm 1,525.10 137.00 208,939
SOR 2014 sand of 1.25 FM).

11.05 CPWD 5.30 Add or deduct for plaster drip course / groove in plastered surface or Metre 200.00 30.75 6,150
DSR 2014 moulding to RCC projections.

11.06 CPWD 13.6.1 20 mm cement plaster of mix Cement mortar 1:4. sqm 3,459.23 242.05 837,307
DSR 2014

11.07 CPWD 7.42 Providing and fixing adjustable stainless steel cramps of approved quality, each 6,134.00 206.15 1,264,524
DSR2014 required shape and size, adjustable with stainless steel nuts, bolts and washer
(total weight not less than 260 gms), for dry stone cladding fixed on frame
work at suitable location, including making necessary recesses in stone slab,
drilling required holes etc. complete

15
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
11.08 CPWD 4.18 Extra for addition of synthetic Polyester triangular fibre of length 12mm, per bag 345.25 53.00 18,298
DSR 2014 effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in of 50kg
cement concrete/RCC/Flooring/water retaining structures by using 125gms of cement
synthetic Polyester triangular fibre for 50 Kg cement used as per directions of
Engineer-in-Charge.

11.09 CPWD derived Providing and fixing dry cladding of granite stone upto 10 Metre heights with sqm 4,603.32 4,940.87 22,744,406
DSR 2014 from 7.40.2 30 mm thick gang saw cut stone with (machine cut edges) of uniform colour
and size upto 1mx1m, fixed to structural steel frame work and/ or with the
help of cramps, pins etc. and sealing the joints with approved weather
sealant as per Architectural drawing and direction of Engineer-in-charge.
(The steel frame work, stainless steel cramps and pins etc. shall be paid for
separately).

11.10 CPWD 7.32.2 White sand stone work, plain in copings, cornices, string course and plinth cum 2.98 39,022.00 116,286
DSR 2014 courses in cement mortar 1:6 ( 1 cement : 6 coarse sand) including pointing
with white cement pointing with white cement mortar 1:2 ( 1 white cement:2
stone dust) with an admixture of pigment matching the stone shade.

Total of Subhead-11 32,729,280

12.00 SH-12 STEEL & STRUCTURAL STEEL WORKS

12.01 CPWD 10.25 Steel work welded in built up sections/ framed work including cutting,
DSR 2014 hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.

12.1.1 CPWD 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar kg 7,600.00 90.10 684,760
DSR 2014 works.
12.02 CPWD derived Steel work in built up Electric resistance or induction butt welded type Kg 13,100.00 123.65 1,619,815
DSR 2014 from tubular ( round, square or rectangular hollow tubes etc) trusses of steel grade
10.16.3 250 including cutting, hoisting, fixing in position and applying a priming coat
of approved steel primer, welded and bolted including special shaped
washers etc. complete.
12.03 NS AR Extra for preparing smooth surface of steel by removal of mill scale by sand sqm 180.00 47.00 8,460
blasting to achieve finish SA 2.5

12.04 NS AR Providing and fixing Hollock wood hand rail for staircase size 65mm x 120mm Metre 152.00 857.20 130,294
fixed to mild steel flat with screws i/c spirit polishing after applying wood filler.

Total of Subhead-12 2,443,329

16
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.00 SH 13 EXTERNAL FAÇADE WORK FOR TOWERS & DOME- ALUMINIUM, GLASS , GLASS
DOORS
13.01 CPWD 26.1 Providing and supplying aluminium extruded tubular and other aluminium kg 43,495.00 338.25 14,712,184
DSR 2014 sections as per the architectural drawings and approved shop drawings , the
aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including
anodised of 25-30 microns conforming to AAMA 2604 of required colour and
shade as approved by the Engineer-in-Charge. ( The item includes cost of
material such as cleats, sleeves, screws etc. necessary for fabrication of
extruded aluminium frame work. Nothing extra shall be paid on this
account).

13.02 CPWD 26.2 Designing, fabricating, testing, protection, installing and fixing in position semi sqm 6,525.04 2,556.15 16,678,981
DSR 2014 (grid) unitized system of structural glazing (with open joints) for linear as well
as curvilinear portions of the building for all heights and all levels, including
Structural analysis & design and preparation of shop drawings for the
specified design loads conforming to IS 875 part III (the system must passed
the proof test at 1.5 times design wind pressure without any failure), including
functional design of the aluminum sections for fixing glazing panels of various
thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws,
toggles, nuts, bolts, clamps etc., structural and weather silicone sealants,
flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets
for water tightness, pressure equalisation & drainage and protection against
fire hazard complete as per item 26.2

17
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.03 CPWD 26.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of sqm 6,525.00 4,090.95 26,693,449
DSR 2014 hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel
units of size and shape as required and specified, comprising of an outer
heat strengthened float glass 6mm thick, of approved colour and shade with
reflective soft coating on surface # 2 of approved colour and shade, an
inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide,
dessicants, including primary seal and secondary seal (structural silicone
sealant) etc. all complete for the required performances, as per the
Architectural drawings, as per the approved shop drawings, as specified and
as directed by the Engineer-in-Charge. The IGUs shall be assembled in the
factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in
the curtain glazing is included in cost of item No.26.2) For payment, only the
actual area of glass on face # 1 of the glass panels (excluding the areas of
the grooves and weather silicone sealant) provided and fixed in position,
shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate
with reflective soft coating on face # 2, + 12mm Air gap + 6mm Heat
Strengthened clear Glass of approved make having properties as visible
Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light
reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of
3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be
decided by technical sanctioning authority as per the site requirement.

13.04 CPWD derived Providing, assembling and supplying of spandrel glass GL1b panels (SGU) of 6 sqm 910.28 3,090.69 2,813,393
DSR 2014 from 26.6 mm thick clear toughened glass with ceramic fritting's 60% density in
structurally glazed units as per approved sample as specified, all complete
as per the approved shop drawings OR as directed by the Engineer-in-
Charge. The glass units shall be assembled in the factory in controlled
conditions / at workshop of the glass processor. (Payment for fixing of glass
Panels in the curtain glazing is included in cost of item No.26.2) For payment,
only the actual area of glass on face # 1 (excluding the areas of the grooves
and weather silicone sealant) shall be measured in sqm.

18
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.05 CPWD 26.5 Providing, fabricating and supplying shadow box of required size and shape, sqm. 877.19 1,631.10 1,430,785
DSR 2014 for fixing in the spandrel portion of the structural glazing, in linear as well as
non-combustible fibre glass wool insulation 50 mm thick, conforming to IS:
curvilinear portions of the building by providing semi -rigid, inorganic,8183
and BS: 3958 Part 5. The insulation layer shall have facing (factory) bonded
on surface # 1of the fibre glass insulation layer), of black nonwoven fibre
glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60
gm. / sqm, made of randomly oriented glass fibres distributed in a binder by
a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing
using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc
complete.

13.06 NS Derived Providing, assembling and supplying of vision glass GL1d panels (IGUs) sqm 216.96 5,046.00 1,094,780
comprising of hermetically-sealed insulated (double glazed) units = Outer
6mm thick high performance toughened glass (SKN 144 Or Equivalent) +
12mm air gap + inner 10mm thick clear toughened glass as per approved
sample-VISION GLASS as specified, all complete as per the approved shop
drawings OR as directed by the Engineer-in-Charge. Payment for fixing of
IGU Panels in the curtain glazing shall be in item no. 14.18.4. For payments,
only the actual area of glass on face # 1 of the glass panels (excluding the
areas of the grooves and weather silicone sealant) shall be measured in sqm.
The approved make glass having properties as minimum visible Light
transmittance (VLT) of 40%, Light reflection internal <20%, light reflection
external <30 %, solar heat gain coefficient (0.25) and U value of < 3.0 W/m2
degree K etc. Subject to approval of colour of glass as decided by Architect
/ Technical sanctioning authority as per the design requirement.
13.07 NS AR Providing, assembling and supplying of spandrel glass GL1e panels (IGUs) sqm 67.80 5,527.00 374,731
comprising of hermetically-sealed insulated (double glazed) units Outer 6mm
thick clear with ceramic fritting 60% density toughened glass (ST150 Or
Equivalent) + 12mm air gap + inner 10mm thick clear toughened glass as per
approved sample.-VISION GLASS specified, all complete as per the
approved shop drawings OR as directed by the Engineer-in-Charge.
Payment for fixing of IGU Panels in the curtain glazing shall be in item no.
14.18.4. For payments, only the actual area of glass on face # 1 of the glass
panels (excluding the areas of the grooves and weather silicone sealant)
shall be measured in sqm.

19
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.08 NS AR Providing, assembling and supplying of vertical glass fin GL1f = 12mm thick sqm 58.80 7,203.27 423,552
clear toughened glass + 1.52 mm thick PVB Lamination + 12mm. Thick clear
toughened glass as per approved sample. (Glass Fin) as per approved
sample as shown in concept drawings OR as directed by the Engineer-in-
Charge. Payment for fixing of fin glass GL1f in the corner glazing shall be paid
in item no. 14.18.4. For payments, only the actual area of glass panels shall
be measured in sqm.

13.09 CPWD 26.8 "Design supply & installation of suspended Spider Glazing system designed to sqm 638.60 3,429.90 2,190,334
DSR 2014 withstand the wind pressure as pr IS 875 (Part-III). The Suspended System held
with Spider Fittings of SS-316 Grade Steel of approved manufacturer with
glass panel having 12 mm thick clear toughened glass held together with SS-
316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21
mm thick. The Glass fins and glass panel assembly shall be connected to
Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor
bolts and at the bottom using SS channel of 50x25x2mm using fastener &
anchor bolts, non staining weather sealants of approved make, Teflon/ nylon
bushes and separators to prevent bi-metallic contacts, all complete to
perform as per specification and approved drawings. The complete system
to be designed to accommodate thermal expansion & seismic movements
etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter &
in U channel of the assembly to be filled with non staining weather sealant,
so as to make the entire system fully water proof & dust proof.

The rate shall include all design, Engineering and shop drawing including
approval from structural designer, labour, T&P, scaffolding , other incidental
charges including wastage, enabling temporary services all fitting fixers nut
bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass
etc. all complete. For the purpose of payment, actual elevation area of
Glazing including thickness of joints and the portion of Glass panel inside the
SS channel shall be measured.
13.10 CPWD 26.07 Designing, fabricating, testing, installing and fixing in position Curtain Wall sqm 165.72 3,775.30 625,643
DSR 2014 with Aluminium Composite Panel Cladding, with open grooves for linear as
well as curvilinear portions of the building , for all heights and all levels etc.
including: a) Structural analysis & design and preparation of shop drawings
for pressure equalisation or rain screen principle as required, proper drainage
of water to make it watertight including checking of all the structural and
functional design.

20
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
b) Providing, fabricating and supplying and fixing panels of aluminium -
composite panel cladding in pan shape in metallic colour of approved
shades made out of 4mm thick aluminium composite panel material
consisting of 3mm thick FR grade mineral core sandwiched between two
Aluminium sheets (each 0.5mm thick). The aluminium composite panel
cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon
based fluoro polymer resin coating of approved colour and shade on face #
1 and polymer (Service) coating on face # 2 as specified using stainless steel
screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.

c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip -


Galvanised with serrations and serrated washers to arrest the wind load
movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS
316, Nylon separators to prevent bi-metallic contacts all complete required
to perform as per specification and drawing The item includes cost of all
material & labour component, the cost of all mock ups at site, cost of all
samples of the individual components for testing in an approved laboratory,
field tests on the assembled working curtain wall with aluminium composite
panel cladding, cleaning and protection of the curtain wall with aluminium
composite panel cladding till the handing over of the building for
occupation. Base frame work for ACP cladding is payable under the
relevant aluminium item's The Contractor shall provide curtain wall with
aluminium composite panel cladding, having all the performance
characteristics all complete , as per the Architectural drawings, as per item
description, as specified, as per the approved shop drawings and as
directed by the Engineer-in-Charge. However, for the purpose of payment,
only the actual area on the external face of the curtain wall with Aluminum
Composite Panel Cladding (including width of groove) shall be measured in
sqm. up to two decimal place.
13.11 NS AR Providing, fixing, supplying and installation of 70mm wide and 25mm deep metre 4,500.00 742.00 3,339,000
horizontal aluminium cap at locations provided with duly anodised coated
profiles (shade as approved) in front, rear and side elevation of building as
shown in drawings / details with 4.0mm thick mill finish aluminium pressure
plate in horizontal direction. Aluminium fin shall be fixed on to the glazing
with EPDM gaskets and pressure plate over glass panels. Pressure plate shall
be fixed with 60-70mm long s.s. screws @ 450mm c/c in all horizontal all
complete as per direction of Engineer-in-charge. ( rough ground payable
extra)

21
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.12 CPWD 26.4 Extra for openable side / top hung vision glass panels (IGUs) including sqm 66.24 3,062.25 202,843
DSR 2014 providing and supplying at site all accessories and hardware's for the
openable panels as specified and of the approved make such as heavy
duty stainless steel friction hinges, min 4 -point cremone locking sets with
stainless steel plates, handles, buffers etc. including necessary stainless steel
screws/ fasteners, nuts, bolts, washers etc. all complete as per the
Architectural drawings, as per the approved shop drawings, as specified and
as directed by the Engineer- in-Charge.
13.13 NS AR Extra for providing, fixing, supplying and installation of openable panel in each 16.00 25,000.00 400,000
dome spider glazing at locations as given in elevation of Dome with
approved make necessary hardware and accessories as per approved
samples. All openable panel shall be air / water tight. Glass cost shall be paid
under item above.
13.14 CPWD 21.11.4 Providing and fixing stainless steel ( SS304 grade ) adjustable friction windows each 60.00 612.05 36,723
DSR 2014 stays of approved quality with necessary stainless steel screws etc. to the side
hung windows as per direction of Engineer-in-charge complete. 510 x 19 mm

13.15 NS AR Providing and fixing of DORMA Automatic Bi-parting sliding door operator ES each 4.00 339,303.46 1,357,214
200 EASY, dimensions of the operator would be 100x 180 x 4250/6150mm.
consisting of Microprocessor control, self-learning, reversing when obstruction
is encountered, clear width upto 3000mm x 2400mm.
Door weight:
1-panel max. 1 x 100 kg
2-panel max. 2 x 85 kg
Function programs:
Off, Automatic, Permanent open, Exit only, Partial open,
EM locking , Eagle Sensor both side, Light barrier, Emergency off. Basic
parameter of door adjustable via integrated display and push-buttons.
Choice between emergency opening and emergency closing in the event
of a power cut (with optional battery pack). Produced according to the
guidelines for power-operated windows, doors and gates BGR 232, the UVV
and the VDE
regulations. TÜV design tested, tested according to the low voltage
guidelines, production according to ISO 9001:2000
certification. Fulfils the DIN V18650 (prEN 12650).
Connection:
230 V, 50/60 Hz
Finish: Silver Anodized

22
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.16 NS AR Design, fabrication and installation of anodised aluminium fixed louvers with sqm 170.07 1,722.00 292,861
tubular section and outer aluminium channel frame at terrace level with m.s.
supporting structure behind as shown in concept details. Aluminium frame,
necessary hardware like s.s. nuts / bolts, frame fixing screws etc. as per the
elevation, sections and details shall be used as per drawings enclosed. 'The
aluminium louvers shall be fabricated out of heavy duty aluminium extruded
built up profiles confirming to alloy 63400 WP with chemical composition and
mechanical properties as per IS:733:1983 and IS 1285:2002. All profiles shall be
anodised in approved shade. ( aluminium quantity payable in DSR item
21.1.1)

13.17 CPWD 21.1.1.1 Providing and supplying aluminium extruded tubular and other aluminium kg 1,633.00 348.50 569,101
DSR 2014 sections for louvers as per the architectural drawings and approved shop
drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS
1474,including Anodising coating AC 15 microns conforming to AAMA 2604 of
required colour and shade as approved by the Engineer-in-Charge. ( The
item includes cost of material such as cleats, sleeves, screws etc. necessary
for fabrication of extruded aluminium frame work. Nothing extra shall be
paid on this account).

13.18 CPWD 21.9.1 Extra for applying additional anodic coating AC 25 instead of AC 15 to kg 49,740.00 11.60 576,984
DSR 2015 aluminium extruded sections for fixed portion

23
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
FRAMELESS GLASS FIXED GLAZING FOR TRAINING HALL, COURSE
COORDINATOR, CLASSROOM & LIBRARY READING ROOM

13.19 NS AR Design, providing, fixing, supplying and installation of frameless glass fixed sqm 510.00 4,693.00 2,393,430
glazing with toughened glass GL2 = 12mm. Thick Clear toughened glass
inside the building, fixed at top with S.S. brackets 316 grade, including cost of
making suitable holes in the glass for installation complete in position in all
respects as per concept drawings and details. The periphery of the glazing
shall be sealed both from inside and outside with silicone weather sealant to
make the glazing's water/ airtight using 2mm thk mill finish aluminium
peripheral channel. Glass to glass joints shall be filled with clear substrate
silicon to have a neat and clean appearance. Silicone sealant of approved
make / grade shall be used as per recommended by the silicon
manufacturer. The glazing shall be aligned for height and width respectively
by lazer beam equipment to ensure 100 percent 'X' axis and 'Y' axis
alignment. The above item cost includes labour's, tools, lifting etc. sealants,
s.s. brackets, fasteners, screws, protective tape, masking tape, backer rods,
bolts, fixtures, scaffolding, etc. complete in all respect. Openable frameless
glass doors cost shall be paid under respective subhead.

13.20 CPWD derived Providing and fixing 12 mm thick clear toughened glass for glazing i/c sqm 720.73 3,024.75 2,180,028
DSR 2014 making necessary holes etc. for fixing, all complete as per direction of
Engineer-in-charge (Hardware etc.to be paid separately).

13.21 NS AR Designing, providing, fixing, supplying and installation of frameless glass fixed sqm 210.73 6,960.00 1,466,681
glazing in lift well in dome area with GL2 12mm. Thick Clear toughened glass,
Over m.s. frame with S.S. spider fittings of approved makes excluding cost of
glass with holes complete in position in all respects as per concept drawings
and details. tha glass to glass joints shall be kept open. The glazing shall be
aligned for height and width respectively by lazer beam equipment to
ensure 100 percent 'X' axis and 'Y' axis alignment. The above item cost
includes labour's, tools, lifting etc. sealants, s.s. brackets, fasteners, screws,
protective tape, masking tape, backer rods, bolts, fixtures, scaffolding, etc.
complete in all respect. The cost of glass shall be paid under item no 14.43.
The cost of m.s. work shall be paid under respective subhead.

24
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.22 NS AR Extra for proving and fixing of frameless glass openable side hung swing door sqm 70.00 14,113.00 987,910
(Double leaf) with 12mm thick toughened clear glass including all necessary
hardware like heavy duty double action hydraulic floor spring, s.s. patch
fittings s.s. handle with lock etc. of approved make with required EPDM
rubber / neoprene gasket on vertical edges complete as per architectural
drawings and the direction of Engineer-in-charge.
13.23 NS AR Extra shall be paid for providing and fixing openable frameless glass door sqm 13.00 16,000.00 208,000
shutters with glass type GL5 in opening provided in above item including s.s.
patch fittings of approved make, lock, 900 mm long 38mm dia s.s. handle,
heavy duty floor spring of approved make. (All samples to be got approved
by the Architect / Facade Consultant before installation). The frameless glass
door shall be installed in position, complete in all respects.
Total of Subhead-13 81,048,605

14.00 SH-14 WOOD WORK - DOORS, PARTITIONS & PANELING


14.01 CPWD 9.1.1 Providing Second class Teak wood work in frames of doors, windows, cum 5.45 91,496.90 498,658
DSR 2014 clerestory windows and other frames, wrought framed and fixed in position
with hold fast lugs or dash fastener of required dia and length ( hold fast lugs
or dash fastener shall be paid for separately).

14.02 CPWD 9.1.3 Providing Kiln seasoned and chemically treated Hollock wood work in cum 10.06 53,698.60 540,208
DSR 2014 frames of doors, windows, clerestory windows and other frames, wrought
framed and fixed in position with hold fast lugs or dash fastener of required
dia and length ( hold fast lugs or dash fastener shall be paid for separately).

14.03 CPWD 9.5.1.1 Providing and fixing 35mm thick second class teak wood panelled or sqm 276.83 2,689.05 744,410
DSR 2014 panelled and glazed shutters for doors, windows and clerestory windows
including ISI marked M.S. pressed butt hinges bright finished of required size
with necessary screws excluding paneling which will be paid separately, all
complete as per direction of Engineer-in-charge.

14.04 CPWD 9.7.7.2 Providing and fixing paneling 5.5mm thick glass panes in panelled or sqm 276.83 1,406.75 389,431
DSR 2014 panelled and glazed shutters for doors, windows and clerestory windows (
area of opening for panel inserts excluding portion inside grooves or rebates
to be measured) .

25
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
14.05 CPWD 9.21.1 Providing and fixing 35mm thick ISI marked flush door shutters conforming to sqm 508.78 1,909.55 971,541
DSR 2014 IS :2202 (Part I) non-decorative type, core of block board construction with
frame of 1st class hard wood and well matched commercial 3 ply veneering
with vertical grains or cross bands and face veneers on both faces of
shutters, including ISI marked Stainless Steel butt hinges with necessary
screws
14.06 CPWD 9.23 Extra for providing lipping with second class teak wood battens 25mm sqm 508.78 365.85 186,137
DSR 2014 minimum depth on all edges of shutters ( over all area of door shutter to be
measured ).

14.07 CPWD 9.24.1 Extra for providing rectangular or square vision panel not exceeding 0.1 sqm sqm. 394.80 139.40 55,035
DSR 2014 in all type of flush door ( cost of glass excluded ) (overall area of door shutter
to be measured )
14.08 CPWD 9.40.1.1 Providing and fixing 2nd class teak wood size 50x12 mm moulded beading metre 558.80 117.95 65,910
DSR 2014 to door and window frames with iron screws, plugs and priming coat on
unexposed surface etc. complete.
14.09 CPWD 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with each 1,260.00 117.35 147,861
DSR 2014 10 mm diameter bolts, nuts and wooden plugs and embedding in cement
concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded
stone aggregate 20mm nominal size)

14.10 CPWD 9.14 Extra for providing ISI marked stainless steel butt hinges instead of black sqm. 276.83 253.50 70,176
DSR 2014 enameled M.S. butt hinges with necessary screws. ( shutters Area shall be
measured)
14.11 NS AR-38 Providing and fixing beveled edge mirror of superior glass (of approved sqm. 91.86 2,227.00 204,572
quality) complete with 6 mm thick BWR plywood ground fixed to wooden
cleats with C.P. brass screws and washers complete.

14.12 NS AR-39 Providing and fixing 12mm x 12mm size and 1mm thick stainless steel U metre 600.00 105.21 63,126
channel in grooves of partitions .

26
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
14.13 CPWD 9.105 Providing and fixing partition upto required height consisting of G.I. frame -
DSR 2014 and required board including providing and fixing of frame work made of
special section power pressed/ roll form G.I. sheet with zinc coating of 120
gsm/sqm(both side inclusive), consisting of floor and ceiling channel 50mm
wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor
and ceiling at the spacing of 610 mm Centre to Centre with dash fastener of
12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws
with nylon plugs and the studs 48 mm wide having one flange of 34 mm and
other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor
and ceiling channel and placed at a spacing of 610mm Centre to Centre by
6 mm dia bolts and nuts, including fixing of studs along both ends of partition
fixed flush to wall with suitable anchor fastener or metal screws with nylon
plugs at spacing of 450 mm Centre to Centre, and fixing of boards to both
side of frame work by 25 mm long dry wall screws on studs, floor and ceiling
channels at the spacing of 300 mm Centre to Centre. The boards are to be
fixed to the frame work with joints staggered to avoid through cracks, M.S.
fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm
each) to be provided at the horizontal joints of two boards, fixed to the studs
using metal to metal flat head screws, including jointing and finishing to a
flush finish with recommended jointing compound, jointing tape, angle
beads at corner (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of
primer suitable for board as per manufacture's specification and top fixed
with wooden beading and direction of engineer in charge etc all complete
as per direction of engineer in charge. (Note Wood work shall be paid under
respective item.)
14.13.1 CPWD 9.105.1 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Sqm 2,875.53 1,325.65 3,811,946
DSR 2014 board conforming to IS: 2095: part I.
14.14 CPWD 12.62 Providing and fixing thermal insulation with Resin Bonded rock wool sqm 2,875.53 328.85 945,618
DSR 2014 conforming to IS: 8183, having density 48 kg/m3,50 mm thick, wrapped in 200
G Virgin Polythene Bags fixed to wall with screw, rawl plug & washers and
held and in position by criss cross GI wire etc. complete as per directions of
Engineer-in-Charge

14.15 CPWD 9.37.1 Providing and fixing 4mm thick decorative veneer plywood facing sqm. 1,736.00 1,156.20 2,007,163
DSR 2014 conforming to IS:1328 ( type I) for plain lining/ cladding with necessary
screws, including priming coat on unexposed surface.

27
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
14.16 CPWD 9.127.2 Providing & fixing 1 thick decorative high pressure laminated sheet of plain / sqm 2,765.09 676.40 1,870,307
DSR 2014 wood grain in gloss / matt / suede finish with high density protective surface
layer and reverse side of adhesive bonding quality conforming to IS: 2046
Type S including cost of adhesive of approved quality

14.17 CPWD 9.140.1 Providing and fixing plain lining with 12mm thick commercial ply conforming sqm 4,655.00 1,059.20 4,930,576
DSR 2014 to IS : 1328 BWR type with necessary screws/nuts & bolts/ nails, including a
coat of approved primer on one face, and fixed on wooden /steel frame
work, complete as per direction of Engineer-in- charge (Frame work shall be
paid for separately).
14.18 NS derived Extra for providing and fixing fire rated 12.5mm thick GRG gypsum board to Sqm 575.00 449.31 258,353
from existing partitions with screws and taping of joints with fiber tape and
9.105.1 compound.
14.19 MP PWD 9.147 Providing and Installation of acoustical wall paneling fabric finish hardened sqm 1,148.00 7,566.00 8,685,768
SOR 2014 square edge, FR grade fabric (colour as approved by Engineer in charge)
wrapped soft fibre core (glass fibre) panel of size 600x2100x25mm having
density 100-120Kgs/ m3, weight 3.0kg/m2 NRC up to 0.9 installed by using
impaling clip. Impaling clips are attached directly to the wall/frame work
with the points extending outward . Then panels shall positioned and pressed
into place .

14.20 CPWD 9.34.4 Providing and fixing 12 mm thick second class teak wood plain lining sqm 21.18 1,672.30 35,419
DSR 2014 tongued and grooved on and including wooden plugs complete with
necessary screws and priming coat on unexposed surface with.

14.21 NS AR-46 Providing, fabricating and fixing Stainless Steel sheet SS-304 grade satin finish metre 1,605.14 2,976.00 4,776,897
1.2mm cladding as skirting and band upto 200mm height fixed with ( canco /
Boun make) fixed to 6mm + 6mm thick flexi ply base with sealant as per
design, edge bent to shape as per drawing.( plywood will be payable extra )

14.22 NS AR-47 Providing and fixing of 6mm + 6mm thick flexi ply base as per design & as metre 1,605.14 573.55 920,628
per drawing.

28
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
14.23 CPWD 21.8.1 Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone metre 501.00 88.75 44,464
DSR 2014 work by providing weather silicon sealant over backer rod of approved
quality as peer architectural drawings and direction of Engineer-in-charge.
Upto 5mm depth and 5 mm width.

CONFERENCE ROOM PARTITION SYSTEM


14.24 NS AR-48 Providing and fixing "Variflex" operable partition of Dorma/Hufcor make sqm 48.00 50,887.00 2,442,576
consisting of series of individual flat elements of 100 mm thick travelling along
the ceiling track assembled to form a solid wall. The sound insulation of the
operable partition should be 52db. Elements must be constructed of a torsion-
free steel horizontal tube frame and torsion-stiff vertical aluminium profiles,
bolted together to make the element strong and sturdy. The frame must be
clad either side with 16mm MDF panels hung in acoustic free suspension from
the panel frame. The elements must be inter-connected by means of a
positive locking concave/convex aluminium profile with an integrated
magnetic strip and sealing lip having a linear attraction of 40N/m. Each
element must have a spindle mechanism which should be connected to the
spring loaded top and bottom retractable seal. The spindle mechanism
should be operated manually by a bayonet connected crank handle that
acts as a lock in function during cranking process. The horizontal top and
bottom seals must be extended manually by crank handle and should
ensure a contact pressure of 800N when the seals are completely extended.
The seal spindle mechanism must be accessible while the panel is hanging
for servicing and adjustment if necessary. Total disassembly of the panel
frame to access internal components is not acceptable. No fixed sweep
seals allowed in top and bottom of the element that would rub against the
track or floor while moving the element. The telescopic element or the end
closure element must open and close 120mm horizontally. The movement of
the telescopic panel and the operation of the horizontal top and bottom
seal and must be operated by a single mechanism. Each element must be
suspended from the track capable of withstanding the load of the element.
The elements shall run with the help of steel clad, multi directional rollers on a
100mm thick aluminum extruded track capable of taking a weight of 500
kgs/ element. Panel should be stacked as per the drawing layout.

29
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
After installation of tracks, a sound barrier should be erected between the
RCC and the false ceiling consisting of 2 gypsum boards of 12.5mm thick
each with mineral wool filling in between having a density of 48kgs/ cubic
meter and fitted to a G.I. sheet framework. Gypsum partition payable
separately.
14.25 NS AR-49 Providing and fixing to the required profile and shape 2 layers of 12.5mm sqm 20.00 6,000.00 120,000
thick Gypsum board on GI framework comprising 40x40x18G galvanized
tubular frame 610x610mm centre to centre fixed on Roof Structure with
40x40x5 MS cleat, 100mm long 1200 c/c and ceiling framework with welded
connections. The Gypsum board to be backed with 50mm thick resin
bonded fiberglass cut to size and inserted in GI framework and held in place
with 28G x 12mm GI wire netting. The first layer of Gypsum board to have
joints over frame and second layer of Gypsum board to have joint staggered
with respect to the first layer, all joints between board in both layers to be
taped with paper tape and filled with sealing compound. Gypsum board
layer to be sealed at junction with Roof sheeting / structure and false ceiling
below with the non-hardening mastic compound, so as to provide smooth
surface. Entire work to be done as per drawing, specifications and as per
directions of Engineer-in-charge.
14.26 NS AR-50 Providing and fixing circular column cladding with 6mm flexi ply and 4mm sqm 471.83 2,756.00 1,300,363
thick natural veneer of approved sample i/c melamine polishing.

14.27 CPWD 10.27.3 Providing and fixing 10 x 120 mm carbon steel galvanised ( minimum coating each 400.00 86.75 34,700
DSR 2014 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield
strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide
PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry,
etc. as per direction of Engineer-in-charge.

Total of Subhead-14 36,121,844

15.00 SH-15 FLOORING, SKIRTING & DADO WORK


FLOORING
15.01 CPWD 11.3.1 40mm thick cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 stone sqm 1,208.00 353.35 426,847
DSR 2014 aggregate 20mm nominal size) finished with a floating coat of neat cement
including cement slurry, but excluding the cost of nosing of steps etc.
complete.

30
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.02 CPWD 11.6.1 Providing and laying 18mm thick Cement plaster skirting (up to 30 cm height) sqm 130.00 377.25 49,043
DSR 2014 with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating
coat of neat cement.

15.03 CPWD 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and sqm 2,255.16 1,141.40 2,574,040
DSR 2014 jointed with grey cement slurry mixed with pigment to match the shade of
the slab, including rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) : 25mm thick

15.04 CPWD 11.41 Providing and laying polished vitrified floor tiles in different sizes (thickness to -
DSR 2014 be specified by the manufacturer) with water absorption's less than 0.08%
and conforming IS : 15622 of approved make in all colours and shades, laid
on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) including
grouting the joints with white cement and matching pigments etc. complete.

15.4.1 CPWD 11.41.2 Size of tiles 60x60cm sqm 725.21 1,405.95 1,019,609
DSR 2014
15.05 CPWD 16.86.1 Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded sqm 17,236.29 3,148.55 54,269,321
DSR 2014 and pre polished machine cut granite stone of required size and shape of
approved shade, colour and texture in footpath, flooring cut granite stone of
required size and shape of approved shade, colour and texture in footpath,
flooring in road side plazas and similar locations, laid over 20mm thick base
of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints
with white cement mixed with matching pigment, epoxy touch ups etc.
complete as per direction of Engineer-in-Charge. stone size Area less than
0.50 sqm. ( Granite rate Rs. 1900 per sqm tax paid)

15.06 CPWD 8.12 Providing and fixing flamed finish Granite stone flooring in required design sqm 2,975.68 3,244.35 9,654,147
DSR 2014 and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawing with 18mm thick stone slab over
20mm (average) thick stone slab over 20mm (average) thick base of cement
mortar1:4(1 cement:4coarse sand )laid and jointed with cement slurry and
pointing with white cement slurry and pointing with white cement slurry
admixed with pigment of matching shade including rubbing, curing and
polishing etc. all complete as per specified and as directed by the Engineer-
in-charge:

31
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.07 CPWD 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy
DSR 2014 grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of
hardener and 0.20 kg of resin per kg), including filling / grouting and finishing
complete as per direction of Engineer-in-charge.
15.7.1 CPWD 11.48.2 Size of Tile 600x600 mm sqm 3,576.00 187.95 672,109
DSR 2014

15.08 CPWD 11.37 Providing and laying ceramic glazed floor tiles 300x300mm in size ( thickness sqm 42.84 785.40 33,647
DSR 2014 to be specified by the manufacturer) of Ist quality confirming to IS : 15622 of
approved make in colours such as white, Ivory , grey , fume red brown laid
on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) including
pointing the joints with white cement and matching pigments etc. complete

15.09 CPWD 11.25 Extra for granite stone flooring in treads of steps and risers using single length sqm 441.68 320.30 141,470
DSR 2014 up to 2.00 metre.

15.10 NS derived Providing and fixing 18mm thick granite in skirting, riser, sills etc. for vertical sqm 1,581.76 3,431.00 5,427,019
surfaces of approved quality and shade laid over 12/15mm (AV.) thick
cement mortar 1:4 ( 1 cement : 4 coarse sand) and jointed with white
cement slurry mixed with pigment to match the granite shade etc. all
complete.
15.11 NS AR Extra for making honed finish surface of granite in treads instead of polished. sqm 596.07 223.57 133,263

15.12 CPWD 11.46 Providing and laying polished vitrified tiles in different sizes (thickness to be -
DSR 2014 specified by the manufacturer) with water absorption's less than 0.08% and
conforming IS : 15622 of approved make in all colours and shades, in skirting,
risers of steps, laid with 12mm thick cement mortar 1:3 ( 1 cement : 3 coarse
sand) including grouting the joints with white cement and matching
pigments etc. complete.

15.12.1 CPWD 11.46.2 Size of tiles 60x60cm in dado sqm 2,851.13 1,415.40 4,035,489
DSR 2014
15.13 CPWD 11.27 Providing and laying 25mm thick Kota stone slabs in skirting, dado, pillars, sqm 701.87 1,191.25 836,103
DSR 2014 risers of steps (area upto 900 sqcm) laid on 12mm thick (Avr) cement mortar
1:3 ( 1 cement : 3 coarse sand) and jointed with grey cement slurry mixed
with pigment to match the shade of stone slabs, including necessary cutting,
rubbing and polishing etc. complete.

32
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.14 CPWD 11.36 Providing and fixing Ist quality ceramic glazed wall tiles conforming to sqm 499.58 836.65 417,974
DSR 2014 IS:15622 (thickness to be specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white
cement mixed with pigment of matching shade complete

15.15 CPWD 8.2.1.2 Providing and laying 18mm thick mirror polished, machine cut marble for sqm 10.00 2,463.55 24,636
DSR 2014 kitchen platforms, vanity counters, facias and similar locations of required
size of approved shade, colour and texture laid over 20mm thick base
cement mortar 1:4 ( 1 cement : 4 coarse sand) with joints treated with white
cement mixed with matching pigment, epoxy touch ups including rubbing,
curing etc. complete at all levels. Raj Nagar plain white marble/ Udaipur
green marble/ Zebra black marble -Area of slab over 0.5 sqm

15.16 CPWD 8.2.2.2 Providing and laying 18mm thick mirror polished, machine cut for kitchen sqm 94.77 3,907.40 370,304
DSR 2014 platforms, vanity counters, facias and similar locations of required size of
approved shade, colour and texture laid over 20mm thick base cement
mortar 1:4 ( 1 cement : 4 coarse sand) with joints treated with white cement
mixed with matching pigment, epoxy touch ups including rubbing, curing
etc. complete at all levels. granite of any colour and shade -Area of slab
over 0.5 sqm
15.17 CPWD 8.3.1 Providing edge moulding to 18mm thick marble stone counters, vanities etc. metre 50.00 136.10 6,805
DSR 2014 including machine polishing to edge to give high gloss finish etc. complete
as per design approved by engineer in charge.

15.18 CPWD 8.3.2 Providing edge moulding to 18mm thick granite stone counters, vanities etc. metre 181.98 230.55 41,955
DSR 2014 including machine polishing to edge to give high gloss finish etc. complete
as per design approved by engineer in charge.

15.19 NS AR Extra for providing and fixing 12mm thick BW plywood behind marble / metre 181.98 191.27 34,807
granite fascia upto 200mm height to fix stone with Araldite adhesive

15.20 CPWD 8.4 Extra for fixing marble / granite stone over and above corresponding item in metre 181.98 247.40 45,022
DSR 2014 facia and drops of width upto 150mm with epoxy resin based ( Araldite or
equivalent) adhesive including cleaning etc. complete

33
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.21 CPWD 8.5 Extra for providing opening of required size & shape for wash basins / each 101.00 386.60 39,047
DSR 2014 kitchens sink in kitchen platform, vanity counters and similar location in opening
marble / stone work including necessary holes for pillar taps etc. including
rubbing and polishing of cut edges etc. complete.

15.22 CPWD 8.12 Providing and laying flamed finish Granite stone flooring in required design sqm 200.00 3,244.35 648,870
DSR 2014 and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone slab over
20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand)
laid and jointed with cement slurry and pointing with white cement slurry
admixed with pigment of matching shade including rubbing , curing and
polishing etc. all complete as specified and as directed by the Engineer-in-
Charge :a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown,
Cat Eye or equivalent.

15.23 CPWD derived Providing and fixing granite Stone work for wall lining upto 10 m height with sqm 320.28 3,070.00 983,260
DSR 2014 from 7.38 special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand), including pointing in white cement with an admixture of
pigment to match the stone shade.

15.24 CPWD Derived Providing and laying polished granite 300 x600mm floor tiles 0f 8mm thickness sqm 3,553.00 1,406.00 4,995,518
DSR2014 in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement :
4 coarse sand) including grouting the joints with white cement and matching
pigments etc. complete.
15.25 CPWD 7.25 Providing and fixing stainless steel cramps of required size and shape for kg 1,000.00 574.65 574,650
DSR 2014 anchoring stone wall lining to the backing or securing adjacent stones in
stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including
making the necessary chases in stone and holes in walls wherever required.

15.26 CPWD 16.75 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete cum 1,225.33 6,848.85 8,392,101
DSR 2014 from batching plant. The ready mixed concrete shall be laid and finished
with screed board vibrator , vacuum dewatering process and finally finished
by floating, brooming with wire brush etc. complete as per specifications
and directions of Engineer-in- charge. (The panel shuttering work shall be
paid for separately). (Note:- Cement content considered in this item is @ 330
kg/cum. Excess/less cement used as per design mix is payable/ recoverable
separately).

34
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.27 CPWD 16.87 Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded sqm 100.00 3,636.40 363,640
DSR 2014 and pre polished machine cut granite stone of required size and shape of
approved shade, colour and texture in footpath, flooring in road side plazas
and similar locations, laid over 20mm thick base of cement mortar 1:4
(1cement : 4 coarse sand) including grouting the joints with white cement
mixed with matching pigment, epoxy touch ups etc. complete as per
direction of Engineer-in-Charge. stone Area less than 0.50 sqm.

15.28 NS AR Extra for making grooves 3mm x 3mm in granite treads with marble cutting metre 500.00 30.05 15,025
machine in straight lines at all levels.
15.29 NS AR-64 Providing and fixing of Forbo flotex flocked floor covering rolls of classic sqm 320.46 3,939.65 1,262,500
shade series having a density of 70 million fibre of nylon 6.6 per M2,Fire test EN-
13501,Appearance Retention Hexapod ISO 140-8,friction slip resistance test
EN 14041 class Ds, sanitized anti microbial treatment with resilient waterproof
backing, anti allergic certified by British allergy foundation, anti static,
thickness 4.3 mm and approximate weight of 1.8kg/sqm of roll form.

15.30 NS AR-65 Providing and laying 14mm thick engineered wood plank flooring in sqm 1,207.39 5,217.78 6,299,895
approved finish with twin click with finger jointed tongue and groove joints
of approved make flooring duly factory PU finish i/c laying with u foam
underlay and protection with 2 layers of polythene after laying . The plank
should be laid with 15mm gap along walls and include proper cutting where
ever required as per plan shown on drawings.

15.31 NS AR-66 Providing and fixing solid Teak wood wooden skirting 18mm thick and 75mm metre 693.92 160.00 111,027
high in walnut finish fixed to walls with screws.

35
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.32 CPWD 11.54.1 Providing and fixing 300mm high from finished floor removable raised/false sqm 95.72 4,002.80 383,148
DSR 2014 access flooring with system and its components of approved make for
different plenum height with possible height adjustment upto 50 mm,
comprising of modular load bearing floor panels supported on G.I.
rectangular stinger frame work and G.I. Pedestal etc. all complete, as per
the architectural drawings, as specified and as directed by Engineer-in-
charge consisting of : a) P providing at required spacing to form modular
framework, pedestals made out of GI tube of thickness minimum 2 mm and
25 mm outer diameter, fully welded on to the G.I. Base plate of size
100mmx100mmx3mm at the bottom of the pedestal tube, G.I. pedestal head
of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer
diameter with two GI Check nuts screwed on the stud for level adjustment
upto 50mm, locking and stabilizing the pedestal head in position at the
required level. The pedestals shall be fixed to the subfloor (base) through
base plate using epoxy based adhesive of approved make or the machine
screw with rawl plug.

15.33 NS AR Providing and fixing 200mm wide SS grating in cutout areas, SS304 grade metre 235.04 800.00 188,032
1.5mm thick as per approved sample.

15.34 CPWD 16.68 Providing and laying 60mm thick factory made cement concrete sqm 405.48 602.20 244,180
DSR 2014 interlocking paver block of M-30 grade made by block making machine with
strong vibratory compaction and of approved size and design /shape laid in
required colour and pattern over and including 50 mm thick compacted
bed of course sand, filling the joints with coarse sand etc. all complete as per
the direction of Engineer-in-charge.

Total of Subhead-15 104,714,503

36
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
16.00 SH-16 FALSE CEILING WORKS
16.01 CPWD 12.45 Providing and fixing at all height false ceiling including providing and fixing
DSR 2014 of frame work made of special sections power pressed from M.S. sheet and
galvanised in accordance with zinc coating of grade 350 as per IS: 277 and
consisting of angle cleats of size 25mm wide x 1.6 mm thick with flanges of
22mm and 37mm at 1200mm center to center one flange fixed to the ceiling
with dash fastener 12.5mm dia x 40mm long with 6mm dia bolts to the angle
hangers of 25x25x0.55 mm of required length and other end of angle hanger
being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the
rate of 1200 mm center to center to which the ceiling section 0.5 mm thick
button wedge of 80 mm with tapered flanges of 26 mm each having clips of
10.5 mm at 450 mm center to center shall be fixed in a direction
perpendicular to G.I. channel with connecting clips made out of 2.64 mm
dia x230mm long G.I. wire at every junction including fixing the gypsum
board with ceiling section and perimeter channels 0.5 mm thick 27 mm high
having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450 mm center to center with 25
mm long drive all screws @ 230 mm interval including jointing and fixing to a
flush finish of tapered and square edges of the board with recommended
filler, jointing tapes, finisher and two coats of primer suitable for board as per
manufactures specification and also including the cost of making openings
for light fittings ,grills, diffusers, cutouts made with frame of perimeter
channels suitably fixed all complete as per drawing and specification and
direction of the Engineer-in-charge but excluding the cost of painting with :

16.1.1 CPWD 12.45.1 12.5 mm thick tapered edge gypsum board conforming to IS: 2095 - part I. sqm 10,003.00 907.10 9,073,721
DSR 2014
16.1.2 CPWD 12.45.2 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: sqm 900.00 1,022.95 920,655
DSR 2014 2095 - part I.
16.1.3 CPWD 12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board. sqm 833.80 1,059.50 883,411
DSR 2014

37
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
16.02 CPWD 12.52 Providing and fixing False ceiling Tiles of approved materials of size 595x595 -
DSR 2014 mm in true horizontal level suspended on inter locking metal grid of hot
dipped galvanised steel sections ( galvanised @ 170 gsm/sqm.) consisting of
main "T" runner suitably spaced at joints to get required length and of size
24x38 mm made from 0.30mm thick (minimum) sheet spaced at 1200mm
center to center and cross "T" of size 24x25 mm made of 0.30 mm thick sheet,
1200 mm long spaced between main "T" at 600mm center to center to form a
grid of 1200x600 mm made of 0.30 mm thick (minimum) sheet to be
interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm
and laying false ceiling tiles of approved texture in the grid including,
,wherever, required, cutting /making, opening for services like diffusers, grills,
light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended
from ceiling using G.I. slotted cleats fixed to ceiling with 6mm dia and 50mm
long dash fasteners, 4mm GI adjustable rods with galvanised level clips
spaced at 1200mm center to center along main T, bottom exposed width of
24 mm of all T-sections shall be pre-painted with polymer paint, all complete
at all heights as per specifications drawings and as directed by Engineer-in-
charge. (The rate is excluding cost of tiles which will be paid separately).

16.2.1 CPWD 12.52.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size sqm 41.80 1,551.55 64,855
DSR 2014 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having
galvanizing of 100 gms/sqm (both sides inclusive) and electro statically
polyester powder coated of thickness 60 microns (minimum), including
factory painted after bending
16.2.2 CPWD 12.52.2 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of sqm 61.60 1,673.50 103,088
DSR 2014 size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having
galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area
with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5,
electro statically polyester powder coated of thickness 60 microns
(minimum), including factory painted after bending and perforation, and
backed with a black Glass fiber acoustical fleece.

16.2.3 CPWD 12.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard sqm 4,309.20 1,155.20 4,977,988
DSR 2014 having glass fibre conforming to IS:2095 part I , of size 595x595 mm, having
perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and
the side borders of 30 mm, backed with non woven tissue on the back side,
having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin
bonded glass wool backing.

38
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
16.03 NS AR Providing and fixing in position grid ceiling suspension system 600mm x sqm 1,109.47 1,103.91 1,224,755
600mm with dune max white mineral fibre tiles 20mm thick having RH99%,
NRC 0.7, Light reflection 88%, Thermal conductivity K=.052, fire performance
UK class 0, consisting of Microlook edge with silhouette grid exposed metal
grids T-section designed for maximum strength with white powder coated
exposed face flanges. Suspension system (Hot Dipped galvanised steel)
sections consists of Main runner of T-shaped section with single rotary
stitching made of GS sheet and 3600mm long, Cross Runners of T-shaped with
double rotary stitching made of GS sheet and Perimeter Section which
consists of perimeter wall angle made from 0.45mm thick GS sheet and
colour white. Grid system (main & cross) to be suspended from the roof with
2.8mm thick G.I wire rods with a galvanised thickness of min. 80 gram per
Sqm using M6 anchor fasteners etc. i/c providing extra framework and
making openings for electrical fittings, A.C diffusers, trap doors etc. complete
as per manufacturer specifications and detailed drawings and as directed
by the architect at all levels.

16.04 NS AR Providing and fixing Trap door in ceiling made of 12mm thick BWR plywood sqm 25.00 1,802.49 45,062
fixed to hardwood framing with SS but hinges with SS screws.

16.05 NS AR Extra labour charges for making Cove in Gypboard and veneered ceiling for metre 4,457.38 65.71 292,894
light fixture placing size 150mm x 200mm.

16.06 CPWD 9.3.2 Providing Kiln seasoned and chemically treated Hollock wood work in frames cum 53.88 48,848.40 2,631,952
DSR 2014 of false ceiling, partitions etc. sawn and put up in position

16.07 CPWD derived Providing and fixing 12mm thick commercial ply to false ceiling frame work sqm 2,494.13 1,059.20 2,641,782
DSR 2014 from conforming to IS : 1328 BWR type with necessary screws/nuts & bolts/ nails,
9.140.1 including a coat of approved primer on one face, and fixed on wooden
/steel frame work, complete as per direction of Engineer-in- charge (Frame
work shall be paid for separately).

16.08 CPWD derived Providing and fixing 4mm thick decorative veneer plywood facing sqm. 2,694.13 1,156.20 3,114,953
DSR 2014 from 9.37.1 conforming to IS:1328 ( type I) for plain lining/ cladding to false ceiling with
necessary screws, including priming coat on unexposed surface.

39
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
16.09 NS AR P/F Channeled Woodworks perforated panels of width 128mm, 16mm thick sqm 1,599.52 4,700.00 7,517,744
and 2440 mm long or as required, made of a high density particle board
substrate with a laminated facing as per the approved shade/ species &
finish and a melamine balancing layer on the reverse side. The boards shall
have a special perforation pattern where the visible surface has a
(“Helmholtz” fluted perforation of 2mm width and 14mm of visible panel /
4mm width and 28mm visible panel) each. The panels shall provide a
minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS
476. The edges of the panels shall be “tongue-and-grooved” to receive
special clips for installation. The back of the perforated panel shall have
sound absorbing non-woven acoustical fleece. The panels shall be mounted
on special aluminium splines using clips approved by the EIC. The installation
of GI sections shall be done to existing wood work framing with screws and
panels are installed as per manfacturer's specifications. INSTALLATION: Install
wooden battens (provided by others) of section 50mmx50mm or as
approved by the EIC on the solid wall horizontally using screws and plugs at
spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for
channeled woodworks (GTPT001) over the lowest and second wooden
batten at an on-center distance of 600mm. Install the first set of wooden
panels by inserting the clips for border channeled woodworks (GTPT002) &
insert the groove of the panel into the projecting flange of the aluminium
clip. Continue installing rows of panels by inserting the tongue into the
groove of the earlier inserted panel & progressively installing clips for inside
channeled woodworks (GTPT003) into the next keel till the height is achieved.
Use clips for border (GTPT002) to finish off.
Total of Subhead-16 33,492,861

17.00 SH-17 WALL FINISHES - INTERNAL & EXTERNAL


17.01 NS AR Making groove in plaster of paris putty on walls and skirting metre 5,000.00 32.80 164,000
17.02 CPWD 13.37.1 White washing with lime to give an even shade, New work ( three or more sqm 4,515.57 16.20 73,152
DSR 2014 coats ).

17.03 CPWD 13.68.1 French spirit polishing two or more coats on new works including a coat of sqm 7,987.49 193.95 1,549,174
DSR 2014 wood filler.
17.04 CPWD 13.81.2 Distempering two with 1st quality acrylic distemper, having VOC (Volatile sqm 4,135.73 45.70 189,003
DSR 2014 Organic Compound ) content less than 50 grams/ litre, of approved brand
and manufacture, including applying additional coats wherever required, to
achieve even shade and colour.

40
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
17.05 CPWD 13.83.2 Wall painting two coats with premium acrylic emulsion paint of interior sqm 56,648.89 75.35 4,268,494
DSR 2014 grade, having VOC (Volatile Organic Compound ) content less than 50
grams/ litre of approved brand and manufacture, including applying
additional coats wherever required to achieve even shade and colour.
17.06 CPWD 13.84.2 Painting with two coats synthetic enamel paint, having VOC (Volatile sqm 1,389.31 71.60 99,475
DSR 2014 Organic Compound) content less than 150 grams/ litre, of approved brand
and manufacture, including applying additional coats wherever required to
achieve even shade and colour.
17.07 CPWD 13.85.1 Applying priming coats with ready mixed pink or grey primer on wood work sqm 1,389.31 36.10 50,154
DSR 2014 (hard and soft wood) having VOC content less than 50 grams/ litre of
approved brand and manufacture.
17.08 CPWD 13.45.1 Finishing walls with textured exterior paint of required shade: New work ( two Sqm. 1,733.00 146.45 253,798
DSR 2014 or more coats applied @ 3.28 litre/10 sqm) over and including base coat of
water proofing cement paint applied @ 2.20kg/10sqm.

17.09 NS AR-67 Wall and ceiling painting with two coats with highly washable antibacterial sqm 1,000.00 250.29 250,290
acrylic emulsion paint, having low VOC (Volatile Organic Compound )
content less than 50 grams/ litre, of OIKOS Ultra satin or equivalent approved
brand and manufacture, including applying a coat of primer and additional
coats wherever required, to achieve even shade and colour.

17.10 CPWD 14.70 Melamine polishing on wood work (one or more coats). Sqm. 7,987.49 76.70 612,640
DSR 2014
Total of Subhead-17 7,510,180

41
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
18.00 SH-18 ALUMINIUM WORK - DOOR, WINDOWS
18.01 CPWD 21.1 Providing, fixing, supplying, installation and design of aluminium work for -
DSR 2014 doors, windows, ventilators and partitions with extruded built up standard
tubular sections/appropriate Z sections and other sections of approved
make confirming to IS: 733 and IS: 1285 fixed with rawl plugs and screws or
with fixing clips or with expansion hold fasteners including necessary filling up
of gaps at junctions, at top , bottom and sides with required PVC / neoprene
felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including cleat angle, aluminium
snap beading for glazing / paneling, CP brass / SS screws all complete as per
architectural drawings and the direction of Engineer-in-charge.(Glazing and
paneling to be paid for separately):

18.1.1 CPWD 21.1.1.1 Fixed Windows -Anodised aluminium (anodised transparent or dyed to kg 2,011.57 348.50 701,032
DSR 2014 required shade according to IS: 1868, Minimum anodic coating of grade AC
15)
18.1.2 CPWD 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade kg 1,673.71 405.90 679,359
DSR 2014 according to IS: 1868, Minimum anodic coating of grade AC 15) -For shutters
of doors, windows & ventilators including providing and fixing hinges/ pivots
and making provision for fixing of fittings wherever required including the
cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for
separately)
18.02 CPWD 21.03.2 Providing, fixing and supplying of 6mm clear toughened SGU glass GL3 in sqm 272.12 1,054.20 286,869
DSR 2014 internal fixed glazing's, openable door / window glazing's and partitions in
corridors adjacent to light well glazing's.

42
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
18.03 CPWD 26.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of sqm 113.15 4,090.95 462,891
DSR 2014 hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel
units of size and shape as required and specified, comprising of an outer
heat strengthened float glass 6mm thick, of approved colour and shade with
reflective soft coating on surface # 2 of approved colour and shade, an
inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide,
dessicants, including primary seal and secondary seal (structural silicone
sealant) etc. all complete for the required performances, as per the
Architectural drawings, as per the approved shop drawings, as specified and
as directed by the Engineer-in-Charge. The IGUs shall be assembled in the
factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in
the curtain glazing is included in cost of item No.26.2) For payment, only the
actual area of glass on face # 1 of the glass panels (excluding the areas of
the grooves and weather silicone sealant) provided and fixed in position,
shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate
with reflective soft coating on face # 2, + 12mm Air gap + 6mm Heat
Strengthened clear Glass of approved make having properties as visible
Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light
reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of
3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be
decided by technical sanctioning authority as per the site requirement.

18.04 CPWD derived Extra for supplying DGU with 16mm air gap and LowE glass SKN 144 in place sqm 113.15 1,212.45 137,189
DSR 2015 from 26.3 of DGU as per CPWD DSR2014 item no. 26.3

18.05 CPWD 21.3.3 Providing and fixing With float glass panes of 8 mm thickness glazing in sqm 378.23 1,338.40 506,223
DSR 2014 aluminium doors, window, ventilators, shutters and partition etc. with PVC /
neoprene gasket etc. complete as per architectural drawing and the
direction of the Engineer-in-charge. ( cost of aluminium snap beading shall
be paid in basic items.)

18.06 CPWD 21.8.1 Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone metre 904.98 88.75 80,317
DSR 2014 work Upto 5mm depth and 5 mm width by providing weather silicon sealant
over backer rod of approved quality as per architectural drawings and
direction of Engineer-in-charge.

43
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
18.07 CPWD 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to kg 6,615.00 312.20 2,065,203
DSR 2014 required shade according to IS: 1868, Minimum anodic coating of grade AC
15) sub frame work for windows and ventilators with extruded built up
standard tubular sections of approved make conforming to IS: 733 and IS:
1285 fixed with rawl plugs and stainless steel screws etc.

18.08 CPWD 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of sqm 110.08 4,746.25 522,467
DSR 2014 approved brand and manufacture, including providing and fixing top &
bottom pivot & spring type fixing arrangement and making necessary holes
etc. for fixing required door fittings, all complete as per direction of Engineer-
in-charge (Door handle, lock and stopper etc.to be paid separately).

18.09 CPWD derived Providing and fixing Microwave cured EPDM gaskets in kg (Above 60grm./m.) kg 590.63 160.00 94,501
DSR 2015 from 9.37.1

Total of Subhead-18 5,536,051

19.00 SH-19 FIRE DOORS & ACCESSORIES


19.01 NS AR Supply and fixing of 2nd class teakwood - door frame of section 120 mm x 70 Rmt. 672.60 1,431.00 962,491
mm with heat activated intumescent fire seal strip of section 10 mm x 4 mm 2
no. of Seals, Fire & Acoustic , Viper make . The frame is duly primer with FR
retardant primer FR880 type primer and FR Paint FRS type. The frame should
be fixed in existing opening with thr help of anchor fastener of appropriate
size as per direction of Engineer in Charge. The manufacturer should be an
ISO certified and IGBC registered member. The approved manufacturer are
Navair , Promat , Godrej , Shakatimet .

44
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.02 NS AR Providing and fixing of 52mm thick Wooden fire rated door shutters tested as
per BS:476 Part- 20 & 22 & IS 3614 Part-2 for stability, integrity and thermal
insulation. Recommended fire door shall have doors tested at CBRI vide test
report FR No. 0291 for maximum rating of 2hrs tested either with or without
vision panel. Individual Test certificates should be available for glass used in
vision lites confirming the required fire ratings. The shutter should be
maximum 52 mm thick upto commercial ply facing and lamination , if
required should be over and above . The core insulation should be asbestos
free comprising of two 12 mm thick Calcium Silicate boards of Pamtech
type , a 100% without Asbestos, having density not more than 900Kg/M3 and
thermal conductivity 0.14 W/m*K with non-combustibility as per BS 476 part 4-
1970 and class-1 surface spread as per BS-476 Part-7-1971 . These boards
sandwiching 20 mm thick fire resistance insulation filler faced with 03 mm
thick commercial ply facing on both faces .. the shutter is provided with heat
activated intumescent fire seal strip of size 20mm x 4 mm mounted in the
grooves of 2nd class teak wood Exposed lipping on all sides except bottom.
The intumescent fire retardant sealant should be used to fill the gaps
between civil opening and frame along with wool insulation so as to fill any
visible gap . The manufacturer should submit desired design test report for a
design tested earlier for 120 minutes fire rating along with Vision Panel tested
at CBRI Roorkee as per direction's of Engineer in Charge. The manufacturer
should be an ISO certified and IGBC registered member. The approved
manufacturer are Navair , Promat , Godrej , Shakatimet .

19.2.1 NS AR Door Shutter with Paint Finish FD -2 sqm 486.00 5,681.00 2,760,966

2hr. Fire rated hollow metal doors - Painted

45
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.03 NS AR Providing and fixing of Hollow metal fire rated doors as per IS 3614 part-1 &
part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277
with the following specification. Recommended fire door shall have doors
tested at CBRI for maximum rating of 2hrs tested . Individual Test certificates
should also be available for glass used in vision lites confirming the required
fire ratings /panels being a part of the fire door assembly. Doors should be
finished in Thermosetting Powder Coating desired RAL Shades. Manufacturer
test certificate shall cover doors both single & double leaf doors and
Hardware's should pass European certificate "CE" of conformity / UL with
required fire ratings. Any deviation in specification and sheet thickness other
than what is mentioned in the test certificates are not allowed. Proper label
confirming the type of door and the hourly rating is mandatory. Approved
manufacturer Navair International Ltd or equivalent subject to architect’s
approval. And should be ISO Certified company.
Door frame shall be double rebate profile of minimum size 154mm X 77 mm
made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. NDRF
154x77 Frames shall be Butt jointed and field assembled with self bolted. The
frames should be finished with Thermosetting Powder Coating in desired RAL
Shade. All provision should be mortised, drilled and tapped for receiving
appropriate hardware. Frames should be provided with back plate bracket
and anchor fasteners for installation on a finished plastered masonry wall
opening.
Door leaf shall be minimum 49mm thick fully flush double skin door with or
without vision lite. Door leaf shall be manufactured from 1.20mm minimum
thick galvanised steel sheet. The internal construction of the door should be
rigid reinforcement pads for receiving appropriate hardware. The infill
material shall be Rockwool treated with Viper FRS 881 LH. All doors NSD 12049
shall be factory prepped for receiving appropriate hardware and provided
with necessary reinforcement for hinges, locks, and door closers. The edges
should be interlocked with a bending radius of 1.4mm. For pair of doors
astragals has to be provided on the meeting stile for both active and
inactive leaf. Vision lite wherever applicable should be provided as per
manufacturers recommendation with a beading and screws from inside.
However the glass should be contraflam Door Lite 11 mm of minimum size
350mm x 500mm clear 120 min fire rated and partially insulated (EW120),
Clear Toughened, interlayered glass having a sound reduction of >37dB, LT
of 86% and compliant to class 2(B)2 category of Impact Resistance as per EN
12600 standard from Saint Gobain. ( Vision panel extra)

46
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
All doors and frames shall be finished with Powder coating in desired Shades. Sqm 82.08 7,135.00 585,641
(FD 4 )
19.04 NS AR Supply and fixing of Interlayered FR Glass of Saint-Gobain, Torch, Glaberwel Nos. 196.00 6,998.00 1,371,608
make minimum 11 mm thick interlayered , 120 minutes fire Rated (EW120, EI
15 minutes ) Non Wired, Toughened Interlayered Glass of approved make
which can also withstand thermal shock upto 800 degree centigrade shall be
used as a glazing (Vision Panel Top/side fixed glazing) and is to be fixed in
between the glass beading by using ceramic fiber in accordance with BS :
476 Part 22/ EN 1363 EN 1364 for stability and integrity of size 300 mm x 500mm
(Clear vision ) and the manufacturer should have tested the glass of similar or
bigger size with any type of door framing from CBRI Roorkee . The Location of
the Fr Glass will be as per the directions of Engineer-in-charge ( Actual Glass
size will be measured for payment).

19.05 NS AR Supply & fixing of SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with Nos. 784.00 361.00 283,024
SS Screws of BB1953 Becker F.S / 3090F DORMA / 8011008 GEZE Make ( 4 Nos
per panel ) (Required For All Doors)
19.06 NS AR Supply & fixing of Single Leaf Panic Bar Set PEL 246/346 Becker F.S. / PHA2000 Nos. 31.00 7,087.00 219,697
Series DORMA / 8026344/45 GEZE Make Panic Bar single / double leaf panic
exit devices. (Required For Fire Staircase & Lift Lobby Location Doors Only)

19.07 NS AR Supply & fixing of Double Leaf Panic Bar Set PEL 246/346 Becker F.S. / Nos. 6.00 17,280.00 103,680
PHA2000 Series DORMA / 8026344/45 GEZE Make Panic Bar single / double
leaf panic exit devices. (Required For Fire Staircase & Lift Lobby Location
Doors Only)
19.08 NS AR Supply & fixing of PEL905 Becker F.S. / PHT-3905 DORMA / 8026301 GEZE Make Nos. 37.00 7,267.00 268,879
Panic Trim For Operation From The Other Side Of The Panic Bar. (Required For
Fire Staircase & Lift Lobby Location Doors Only)
19.09 NS AR Supply & fixing of SS D Type Pull Handle of size 300mm mm Long of PHD2230 Nos. 306.00 550.00 168,300
Becker F.S/ 8133006 GEZE/ TGDI30022 DORMA Make.(Required For
ELECTRICAL SHAFT, LV ROOM,AHU, DATA CENTRE,HUB, LT PANEL ROOM, UPS ,
SERVER ROOM )
19.10 NS AR Supply & fixing of Stainless Steel 304 grade 300mm Long Tower Flush Bolt of Nos. 48.00 414.00 19,872
BFBS1930 Becker FS/ 9114306 DORMA/ 8157007 GEZE Make with necessary
screws as required. (Required For ELECTRICAL SHAFT, LV ROOM,AHU, DATA
CENTRE,HUB, LT PANEL ROOM, UPS , SERVER ROOM IN DOUBLE LEAF DOORS
ONLY.
19.11 NS AR Supply & fixing of door closers of BLC-0408 Becker F.S/ TS-73V DORMA / TS2000 Nos. 196.00 4,260.00 834,960
GEZE Make. (Required For All Fire Door)

47
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.12 NS AR Supply & fixing of anchor fasteners of HILTI/ FISHER/ Equivalent of maximum Nos. 1,278.00 97.00 123,966
120mm length.

19.13 CPWD 13.58 Providing and applying two coats of fire retardant paint unthinned on sqm 972.00 247.65 240,716
DSR 2014 cleaned wood/ply surface @ 3.5 sqm per litre per coat including
preparation of base surface as per recommendations of manufacturer to
make the surface fire retardant.

19.14 NS AR Supply & fixing of Mortise Dead Lock DL7260 Becker F.S. / 288A DORMA / Nos. 84.00 3,865.00 324,660
8014002/ 8245207 GEZE Make. (Required For ELECTRICAL SHAFT, LV
ROOM,AHU, DATA CENTRE,HUB, LT PANEL ROOM, UPS , SERVER ROOM )

Total of Subhead-19 8,268,459

20.00 SH-20 STAINLESS STEEL & GLASS RAILING WORKS

20.01 CPWD 10.28 Providing and fixing stainless steel (Grade 304) railing (1.0m high from F.F.L. as kg 3,881.60 619.40 2,404,263
DSR 2014 per concept detail drawings) made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary stainless steel nuts
and bolts complete, i/c fixing the railing with necessary accessories &
stainless steel dash fasteners , stainless steel bolts etc., of required size, on the
top of the floor or the side of waist slab with suitable arrangement as per
approval of Engineer-in-charge, (for payment purpose only weight of
stainless steel members shall be considered excluding fixing accessories such
as nuts, bolts, fasteners etc.). Laminated glass shall be paid separately under
item.

48
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
20.02 NS AR Providing, fixing, supplying and installation of glass GL7 =6mm thick clear sqm 399.00 4,246.00 1,694,154
toughened glass + 1.52 mm thick PVB Lamination + 6mm. Thick clear
toughened glass as per approved ( 750mm in height glass), glass as per
approved sample fixed in position on to grade 304 S.S. balusters and
connectors with S.S. handrail as per concept detail drawings enclosed. 'The
item includes required holes, Labour, scaffolding, sales tax / VAT, excise duty
etc. complete in all respect. All S.S. items shall be paid separately.

20.03 NS AR Providing, fixing, supplying and installation of glass GL8 =8mm thick clear sqm 100.00 6,500.00 650,000
toughened glass + 1.52 mm thick SGP Lamination + 8mm. Thick clear
toughened glass as per approved, (1350mm in height glass), glass as per
approved sample fixed in position on to grade 304 S.S. connectors with S.S.
handrail as per concept detail drawings enclosed. 'The item includes
required holes, Labour, scaffolding, sales tax / VAT, excise duty etc. complete
in all respect. All S.S. items shall be paid separately.

Total of Subhead-20 4,748,417

21.00 SH-21 HARDWARE FOR DOORS

21.01 CPWD 9.97.1 Providing and fixing 300x10mm size aluminum tower bolts ISI marked each 234.00 112.10 26,231
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete

21.02 CPWD 9.97.4 Providing and fixing 150x10mm size aluminum tower bolts ISI marked each 397.00 65.35 25,944
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete
21.03 NS AR Providing and fixing stainless steel 304 grade satin finish Male / female sign each 50.00 1,460.40 73,020
plate 125mm x 125mm with smooth edges and rounded corners with SS star
screws to shutters, with marking in black.

21.04 CPWD 9.113 Providing & fixing bright finished 100mm mortice lock with 6 levers without each 224.00 465.95 104,373
DSR 2014 pair of handles for aluminum door with necessary screws etc. complete (Best
make of approved quality) as per direction of Engineer-in-charge.

49
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
21.05 NS based 9.83 Providing and fixing rack and pinion non-handed door closer of Dorma TS Each 284.00 7,878.50 2,237,494
73V size 2-4, with standard arm and with two independent closing valves and
latching speed adjustable by arm, conforming to EN 1154. The door closer
shall be with open hold open function.

21.06 NS based 9.82 Providing and fixing Satin stainless steel door stopper wall mounted dome each 52.00 646.53 33,620
60mm length Dorma 4012

21.07 NS AR Providing and fixing dead lock type package type 1 with 55mm backset, each 148.00 3,774.27 558,592
euro profile cylinder combination of half cylinder 42mm / 60mm both side
key operated cylinder / 60mm one side key other side thumb turn cylinder ,
strike plate, escutcheon in S.S. finish . Model 278a Dorma, complete.

21.08 NS AR Providing and fixing dead lock type package type 1 with 55mm backset, each 88.00 4,055.04 356,844
euro profile cylinder combination of half cylinder 42mm / 60mm both side
key operated cylinder / 60mm one side key other side thumb turn cylinder ,
strike plate, escutcheon in S.S. finish . Model 288a Dorma, complete.

21.09 NS AR Providing and fixing 900mm long 38mm dia stainless steel pull handles SS 304 pair 52.00 11,000.00 572,000
grade, back to back with adjustable for fixing to shutter, washers, raised
beveling on the outer surface, etc. Model TGDI -H900 etc. complete.

21.10 NS AR Providing and fixing Dorma make floor spring BTS 75V EN 1-4 in doors with top each 50.00 18,770.76 938,538
pivot, bottom pivot and stainless steel cover plate with back check and
adjustable closing speed from 175 deg. As per EN 1154 and CE marked i/c
cutting of glass for patch fittings, cutting and repairing of floor.

21.11 CPWD 21.04.1 Providing and fixing double action hydraulic floor spring of approved brand each 2.00 2,039.00 4,078
DSR 2014 and manufacture conforming to IS : 6315, having brand logo embossed on
the body / plate with double spring mechanism and door weight upto 125
kg, for doors, including cost of cutting floors, embedding in floors as required
and making good the same matching to the existing floor finishing and
cover plates with brass pivot and single piece M.S. sheet outer box with slide
plate etc. complete as per the direction of Engineer-in-charge -With stainless
steel cover plate minimum 1.25 mm thickness

50
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
21.12 CPWD 21.12 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm -
DSR 2014 thick & 2100 mm long with SS screws etc .complete as per direction of
Engineer-in-Charge.

21.12.1 CPWD 21.12.1 Anodized (AC 15 ) aluminium tubular handle bar each 216.00 463.00 100,008
DSR 2014
21.13 CPWD 9.101 Providing and fixing aluminium hanging floor door stopper, ISI marked, -
DSR 2014 anodised (anodic coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour and shade, with necessary screws
etc. complete.
21.13.1 CPWD 9.101.2 Twin rubber stopper each 10.00 83.95 840
DSR 2014
21.14 CPWD 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised -
DSR 2014 anodic coating not less than grade AC 10 as per IS : 1868), transparent or
dyed to required colour or shade, with nuts and screws etc. complete :

21.14.1 CPWD 9.96.2 Tower Bolt 250x16 mm each 52.00 189.00 9,828
DSR 2014
21.15 CPWD 21.13 Providing and fixing 100mm brass locks (best make of approved quality) for each 72.00 418.65 30,143
DSR 2014 aluminium doors including necessary cutting and making good etc.
complete.
21.16 NS AR Providing and fixing 300mm long 22mm dia stainless steel pull handles SS 304 each 8.00 2,759.10 22,073
grade, back to back with adjustable for fixing to shutter, washers etc.
complete.

21.17 NS AR Providing and fixing Frameless door s.s. patch fittings top and bottom set each 4.00 2,400.00 9,600
(Ozone/Dorma or equivalent)

21.18 NS AR Providing and fixing Dorma or equivalent make floor lock SS for glass doors each 4.00 3,500.00 14,000

21.19 NS AR Providing and fixing Dorma make floor half dome door stopper 45mm dia each 411.00 370.00 152,070
with fixing accessories in satin chrome for glass doors

21.20 CPWD 14.34 Providing and fixing 150mm bright finished floor brass door stopper with each 114.00 210.75 24,026
DSR 2014 rubber cushion, screws etc. to suit shutter thickness complete.

21.21 NS AR Providing and fixing Baby latch CP brass as per approved sample. each 10.00 120.00 1,200
Total of Subhead-21 5,294,520

51
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
22.00 SH-22 EXTERNAL FAÇADE - ALUMINIUM LOUVERS FRAMING
22.01 CPWD 7.41 Providing and fixing structural steel frame ( for dry cladding with 30mm thick kg 5,100.00 143.55 732,105
DSR 2014 gang saw cut with machine cut edges sand stone ) on walls at all heights
using M.S. square / rectangular tube in the required pattern as per
architectural drawing including cost of cutting, bending, welding etc. The
frame work shall be supported in wall with the help of MS brackets / lugs of
angle iron / flats etc. which shall be welded to the frame and embedded in
brick wall with cement concrete block 1:2:4 ( 1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) of size 300x230x300mm
including necessary cost of centering and shuttering and with approved
expansion hold fasteners on CC / RCC surface including drilling necessary
holes. Approved cramps / pins etc. shall be welded to the frame work to
support stone cladding the steel work will be given a priming coat of Zinc
primer as approved by Engineer-in-charge and painted with two or more
coats of epoxy paint ( shop drawings shall be submitted by the contractor to
the Engineer-in-charge for approval before execution). The frame work shall
be fixed in true horizontal & vertical lines / planes. ( Only structural steel
frame work shall be measured for the purpose of payment, stainless steel
cramps shall be paid for separately and nothing extra shall be paid ).

Total of Subhead-22 732,105

23.00 SH-23 MISCELLANEOUS ITEMS


23.01 NS AR Making holes upto 75mm dia with core cutting machines of required size and each 50.00 350.00 17,500
shape in post RCC work at designated locations if not mentioned in the
drawings but required by Project Manager including cutting of reinforcement
etc. all levels complete. The depth of each hole would be up to 300 mm in
vertical or horizontal RCC surface/s.
23.02 NS AR Making holes upto 175mm dia with core cutting machines of required size each 50.00 800.00 40,000
and shape in post RCC work at designated locations if not mentioned in the
drawings but required by Project Manager including cutting of reinforcement
etc. all levels complete. The depth of each hole would be up to 300 mm in
vertical or horizontal RCC surface/s.

52
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
23.03 NS AR Supplying, drilling/ cleaning hole and injecting Hilti or equivalent ETA -
approved HIT-RE 500 chemical with the help of Hilti HDM 500 dispenser, into a
hole of dia and depth as per manufacture's structural consultant
specifications and fixing rebar's of required diameters subsequently . The
chemical should be have successful usage in wet / water saturated concrete
/ diamond cored holes. The chemical should have approval against creep
and corrosion. Fixing methodology to be followed as per manufacturer
guidelines. Steel will be paid under separate head. Manfacturer's to submit
rebar depth calculations basement on design loads and other parameters
as provided by Consultant and in accordance with EOTA - TR -023/029
guidelines for post installed rebar connection for approval.

23.3.1 NS AR 10mm Dia, rebar 150mm depth each 4,065.00 153.98 625,929

23.3.2 NS AR 12mm Dia, rebar 180mm depth each 2,439.00 308.00 751,212

23.3.3 NS AR 16mm Dia, rebar 240mm depth each 406.00 538.95 218,814

23.3.4 NS AR 20mm Dia, rebar 300mm depth each 203.00 1,047.00 212,541

23.3.5 NS AR 25mm Dia, rebar 375mm depth each 81.00 2,301.77 186,443

23.04 NS AR Supplying, drilling/ cleaning hole and fixing Hilti or equivalent make heavy -
duty ETA approved Toque controlled expansion HSL -3-B mechanical anchor
of appropriate size in concrete and fixing plates subsequently. The anchor
should be consist of 8.8 grade bolt with safety cap, washers, distance sleeve,
expansion sleeve, cone and a collapsible plastic section. All steel
components should be galvanised to minimum 5 microns. Red cap should
come out after required setting torque is applied for installation.
manufacturer should submit anchor design report based on design loads
and other parameters as provided by consultant. Metal anchors should be
designed in accordance with ETAG 001 annexure C guidelines for
anchorage of metal anchors for use in concrete. Application at site should
23.4.1 NS AR be done
M12 as per manufacturer
of standard length guidelines. each 129.00 785.85 101,375
23.4.2 NS AR M16 of standard length each 127.00 1,468.56 186,507
23.4.3 NS AR M20 of standard length each 89.00 2,499.84 222,486
23.4.4 NS AR M24 of standard length each 127.00 3,294.28 418,374

53
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
23.05 MP SOR 12.18.2 Providing and Fixing of sky lights consisting of Multi cell/tight cell sqm 320.00 3,546.00 1,134,720
2014 Polycarbonate Panel System of approved colour, 16mm thick (minimum)
having uniform in color with an integral Tight-Cell core constructed not to
exceed 4mm x 4mm in a cross section, Vertical Standing Seam
manufactured at both sides of the panel. Snap-on connector to interlock
the panels shall have a grip-lock double tooth locking mechanism to ensure
maximum uplift capability & shall be of same color as that of panel. Panel
shall be factory sealed/end welded panels with additional End-
cap/Aluminium U-Profile (mill finish) for ends. Panel shall be co-extruded with
special anti glare compound and UV protected. The full system shall be
fitted on MS purlins perpendicular to direction of sheeting with purlin spacing
as specified by Manufacturer.  The weight of the panel only shall not be less
than 3250 gram per square metre.

The rate includes cost of all the operations, labour & all materials and tests
(as applicable) involved such as bolts nuts and screws etc. and labour for
cutting bending to required profile, necessary scaffolding, hoisting in position
etc. for proper completion of the work etc. complete as per specification
drawings and direction of Engineer in charge . Finished surface area of
roofing fixed over steel tubular structure shall be measured for payment. MS
tabular frame work shall be measured separately for payment )

Total of Subhead-23 4,115,900

54
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
24.00 SH-24 MODULAR WATER CLOSET CUBICLES

24.01 NS AR Providing & fixing toilet cubicle systems L-Shape Toilet cubicle with standard each 50.00 41,195.00 2,059,750
dimensions of 2025 mm (H) x 1000mm (W) x 1550mm (D) consisting of 600mm
width of door of app. equivalent make & manufactured with 12mm thick
solid Compact Laminate panels i/c doors, pilasters & intermediate panels,
which should be resistant to heat, bacteria, water, chemical, scratch &
impact. Finished product should be as per approved texture, shade &
drawing detailing & developed according to IS-2046 & BS-476/97 standards.
The toilet cubicle setup shall include necessary hardware fittings, made out
of stainless steel (Grade-304), as per manufacturer’s specifications &
approved by EIC. Hardware fittings should consist of (1) Stainless steel Door
knob , (2) Stainless steel Gravity hinges (3 nos.) not less than 75mm length &
weight not less than 210 grams, (3) Stainless steel Thumb-turn lockset with
indicators, (4) Stainless steel Coat hook with nylon door stopper (5) Stainless
steel U-channels of 20 gauge and 12X20mm size (6) Stainless steel Adjustable
foot/pedestal to give 150mm clearance from bottom & of weight not less
than 600grams. (7) Stainless steel Top rail pipe(OD:24mm of 18 gauge) with
corner connectors (8) Stainless Steel Head Rail Tubular Holder of weight not
less than 200 grams. (9) Rubber noise deafening tape
(10) Stainless steel Screws & wall plugs. The top fitting arrangement shall
comprise of stainless steel (round) top rail, fixed to pilasters & stainless steel
tubular holder. Stainless steel wall fixing roses shall be used on the wall to hold
the top rail. In absence of brick walls, stainless steel corner bends (connected
to the top rail) will be used on the corners of the cubicle.

All screws should be of stainless steel (Grade-304). All pilasters will be


supported by stainless steel adjustable foot. The base of the stainless steel
bottom cladding will be anchored to the floor with a clearance height of
150mm.The intermediate panel shall be of one continuous panel without any
joint. All visible edges will be chamfered, The height of the panel shall be
measured exclusive of bottom clearance of 150 mm .

Total of Subhead-24 2,059,750

55
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY - HOSTEL BLOCK ( H1,H2 )

SUB HEAD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

CIVIL WORKS

SH-1 EARTH WORK 1,348,743

SH-2 PILING WORKS 26,743,787

SH-3 ANTITERMITE TREATMENT 138,942

SH-4 PLAIN CEMENT CONCRETE WORK 2,267,203

SH-5 REINFORCED CEMENT CONCRETE WORK 50,973,805

SH-6 FORM WORK 19,084,661

SH-7 STEEL REINFORCEMENT WORK 80,960,256

SH-8 BRICK WORK 15,948,283

SH-9 WATER-PROOFING OF RAFT, RETAINING WALL, DECK SLAB, ROOFS, INTERNAL WET AREAS 18,629,923

SH-10 INSULATION - OVERHEAD & UNDERDECK 1,713,356

SH-11 PLASTERING - INTERNAL AND EXTERNAL 18,805,645

SH-12 STEEL WORKS 5,372,923

56
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-13 EXTERNAL FAÇADE WORK - ALUMINIUM, GLASS , GLASS DOORS 978,888

SH-14 WOOD WORK - DOORS, PARTITIONS & PANELING 4,362,707

SH-15 FLOORING, SKIRTING & DADO WORK 42,574,503

SH-16 FALSE CEILING WORKS 4,490,659

SH-17 WALL FINISHES - INTERNAL & EXTERNAL 6,040,422

SH-18 ALUMINIUM WORK FOR DOOR, WINDOWS 44,006,200

SH-19 FIRE DOORS & ACCESSORIES 4,295,067

SH-20 STAINLESS STEEL & GLASS RAILING WORKS 7,685,955

SH-21 HARDWARE FOR DOORS 269,644

SH-22 EXTERNAL FAÇADE - GRC SCREENS, ALUMINIUM LOUVERS 794,913

SH-23 MISCELLANEOUS ITEMS 2,589,730

ESTIMATED COST 360,076,215

LESS 5% FOR UPRNN WORKING (18,003,811)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 342,072,404

57
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
BILL OF QUANTITIES - CIVIL AND INTERIOR WORKS- HOSTEL BLOCKS
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

1.00 SH-1 EARTH WORK


1.01 UPPWD 251(4.1.1) Excavation in foundations in ordinary soil (loam, clay and sand) including lift cum 12,937.00 92.00 1,190,204
SOR 2014 upto 1.5m. (5fts.) and lead upto 30m. (100fts) and including filling, watering
and ramming of excavated earth in to the trenches and into the space b/w
the building and sides of foundation trenches or in to the plinth and removal
and disposal of surplus earth as directed by the engineer-in-charges up to a
distance of 30m. (100 fts) from the foundation trenches.

1.02 CPWD 2.25 Filling available excavated earth (excluding rock) in trenches, sides of cum 711.29 112.40 79,949
DSR 2014 foundations , plinth, etc. in layers not exceeding 20 cm. in depth,
consolidating each deposited layer by ramming and watering i/c lead upto
50 M and lift upto 1.5M. (Measurement after complete consolidation will be
considered for payment).
1.03 UPPWD 254(4.3) Add to item 251 for every additional 30m. (100 fts.) lead or part of 30m. (100 Cum. 6,045.40 13.00 78,590
SOR 2014 fts) or for every additional 1.5m. (5fts) lift or part of 1.5m (5 fts).

Total of Subhead-1 - 1,348,743

2.00 SH-2 PILING WORKS


2.01 CPWD 20.2A.2 Boring, providing and installing 750 mm dia piles bored cast-in-situ reinforced metre 3,570.00 5,215.40 18,618,978
DSR 2014 cement concrete piles of grade M-25 of specified diameter and length
below the pile cap, to carry a safe working load not less than specified
excluding the cost of steel reinforcement but including the cost of
appropriate length for setting out and removal of same and the length of
the pile to be embedded in the pile cap etc. by crawler mounted,
telescopic boom hydraulic piling rig all complete , including removal of
excavated earth with all lifts and leads (Length of pile for payment shall be
measured upto bottom of pile cap). Tuck mounted rotary / TMR / tube well
boring machine shall not be used.

58
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.02 CPWD 20.2.3 Boring, providing and installing 450 mm dia piles bored cast-in-situ reinforced metre 3,584.00 1,665.35 5,968,614
DSR 2014 cement concrete piles of grade M-25 of specified diameter and length
below the pile cap, to carry a safe working load not less than specified
excluding the cost of steel reinforcement but including the cost of
appropriate length for setting out and removal of same and the length of
the pile to be embedded in the pile cap etc. by percussion drilling using
direct mud circulation ( DMC) or bailer and chisel technique by tripod and
mechanical winch machine all complete , including removal of excavated
earth with all lifts and leads (Length of pile for payment shall be measured
upto bottom of pile cap). Tuck mounted rotary / TMR / tube well boring
machine shall not be used.
2.03 CPWD 20.3.1 Boring, Providing and installing cast in situ single under reamed piles of metre 781.00 2,123.15 1,658,180
DSR 2014 300mm diameter and length below pile cap in M-25 cement concrete, to
carry a safe working load not less than specified, excluding the cost of steel
reinforcement but including the cost of boring with bentonite solution and
the length of the pile to be embedded in pile cap etc. all complete. (Length
of pile for payment shall be measured upto to the bottom of pile cap) :

2.04 CPWD 20.6.1.2 Carrying out routine Vertical load testing on single pile upto 50 tonne in per test 5.00 17,422.50 87,113
DSR 2014 accordance with IS 2911 (Part IV) including installation of loading platform
by Kentledge method and preparation of pile head or construction of test
cap and dismantling of test cap after tests etc. complete as per
specifications and the direction of engineer in charge ( Test load 1.5 times
the safe capacity)
2.05 CPWD 20.6.2.1 Carrying out Initial Vertical load testing on piles above 50 tonne to 100 tonne Per test 2.00 46,808.45 93,617
DSR 2014 in accordance with IS 2911 (Part IV) including installation of loading platform
by kentledge method and preparation of pile head or construction of test
cap and dismantling of test cap after test etc. complete as per
specifications and the direction of engineer in charges pile dia 300mm to
600mm dia.
2.06 CPWD 20.6.2.2 Carrying out routine Vertical load testing on single pile above 50 tonne to per test 3.00 26,714.50 80,144
DSR 2014 100 tonne in accordance with IS 2911 (Part IV) including installation of
loading platform by kentledge method and preparation of pile head or
construction of test cap and dismantling of test cap after test etc. complete
as per specifications and the direction of engineer in charge. ( Test load 1.5
times the safe capacity)

59
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.07 CPWD 20.9 Integrity testing of pile using Low Strain/Sonic Integrity Test/Sonic Echo Test Per test 116.00 745.50 86,478
DSR 2014 method in accordance with IS 14893 including surface preparation of pile
top by removing mud, dust & chipping lean concrete lumps etc. and use of
computerized equipment and high skill trained personal for conducting the
test & submission of results, all complete as per direction of engineer-in-
charge.
2.08 CPWD derived Dismantling / Breaking top portion of concrete piles up to pile cut off level cum 115.69 1,302.30 150,663
DSR 2014 from 15.3 and removing rubbish/spoil up to a lead of 50m with all lifts, cleaning top
portion of pile cleaning reinforcement exposed due to breaking of pile top,
bending pile reinforcement into pile cap as per drawing and instruction of
engineer.
Total of Subhead-2 26,743,787

3.00 SH 3 ANTITERMITE TREATMENT


3.01 CPWD 2.34.1 Supplying chemical emulsion in sealed containers including delivery as litre 186.00 168.83 31,402
DSR 2014 specified - chloryphos / Lindane emulsifiable concentrate of 20%

3.02 CPWD derived Diluting and injection chemical emulsion (to be supplied free of cost at site Sqm 932.69 115.30 107,539
DSR 2014 '2.35.1+ of work) for pre-constructional. Anti termite treatment and creating a
2.35.2+ continuous chemical barrier as per IS : 6313 part II 1981 under and all-round
2.35.3 the column pits, wall trenches, basement excavation, top surface of plinth
filling, junction of wall and floor along the external perimeter of building,
expansion joints, over the top surface of consolidated earth on which apron
is to be laid, surrounding of pipes and conduits etc., complete as
specifications (plinth area of the building at ground floor only shall be
measured for payment) Chlorpyriphos Emulsifiable concentrate 20% with 1%
concentration.
Total of Subhead-3 - 138,942

4.00 SH-4 PLAIN CEMENT CONCRETE WORK


4.01 CPWD 4.20 Providing and laying in position ready mix plain cement concrete, with -
DSR 2014 cement content as per approved design mix and manufacture in fully
automatic batching plant and transported to site of work in transit mixer for
all leads, having continuous agitated mixer, manufactured as per mix design
of specific grade for plain cement concrete work, including pumping of RMC
from transit mixer to site of laying i/c curing excluding cost of centering and
shuttering and finishing i/c cost of curing, admixtures in recommended
portion as per IS 9103 to accelerate / retard setting of concrete , improve
workability without impairing strength and durability as per the directions of
engineer in charge.

60
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Note : (1) Excess or less cement used in this item is payable / recoverable -
separately.

4.1.1 CPWD 4.20.1 All works upto plinth level -


DSR 2014
4.1.1.1 CPWD 4.20.1.2 M10 grade plain cement concrete ( cement content considered @ 220 kg cum 456.66 4,964.75 2,267,203
DSR 2014 per cum)
Total of Subhead-4 - 2,267,203

5.00 SH-5 REINFORCED CEMENT CONCRETE WORK


RMC - -
5.01 CPWD 5.40 Providing and laying in position ready mix M25 grade concrete for reinforced - -
DSR 2014 cement concrete work, using fly ash and cement content as per approved
design mix and manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having continuous
agitated mixer, manufactured as per mix design of specific grade for plain
cement concrete work, including pumping of RMC from transit mixer to site
of laying i/c curing excluding cost of centering and shuttering and finishing
i/c cost of curing, admixtures in recommended portion as per IS9103 to
accelerate / retard setting of concrete , improve workability without
impairing strength and durability as per the directions of engineer in charge.
cement content considered in this item is @ 330 kg per cum of concrete.
Note : (1) Excess or less cement used as per design mix is payable /
recoverable separately. 2. Fly ash confirming to grade I of IS 3812 ( Part 1)
only be used as part replacement of OPC as per IS 456. Uniform blending
with cement is to ensured in accordance with clause 5.2 and 5.2.1 of IS 456-
2000 in the items of B.M.C and R.M.C.

5.1.1 CPWD 5.40.1 All works upto plinth level cum 2,702.29 6,561.20 17,730,265
DSR 2014
5.1.2 CPWD 5.40.2 All works above plinth level and upto floor V level cum 4,324.73 7,279.60 31,482,305
DSR 2014
5.02 CPWD 5.34.1 Extra for providing richer mixes at all floor levels for providing M-30 grade cum 324.66 76.50 24,836
DSR 2014 concrete in place of M-25 grade B.M.C./R.M.C. ( cement content
considered in M30 @ 340kg. per cum of concrete)

5.03 CPWD 5.34.2 Extra for providing richer mixes at all floor levels for providing M-35 grade cum 2,812.91 152.95 430,235
DSR 2014 concrete in place of M-25 grade B.M.C./R.M.C. ( cement content
considered in M35 @ 350kg. per cum of concrete)

61
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
5.04 CPWD 5.38 Extra for R.C.C. / B.M.C. / R.M.C. work above floor V level for each four floors cum 3,501.71 174.20 609,998
DSR 2014 or part there of.
5.05 CPWD 5.13 Providing, hoisting and fixing upto floor five level pre cast reinforced cum 50.07 8,797.80 440,506
DSR 2014 concrete work in small lintels not exceeding 1.5 M clear span including cost
of required centering & shuttering but excluding the cost of
reinforcement1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 20mm
nominal size)

5.06 CPWD 5.15 Providing, hoisting and fixing upto floor five level pre cast reinforced cum 9.00 8,191.40 73,723
DSR 2014 concrete in lintels, beams and bressumers including setting in cement mortar
1:3 ( 1 cement : 3 coarse sand ) cost of required centering , shuttering
complete but excluding the cost of reinforcement with 1:2:4 ( 1 cement : 2
coarse sand : 4 stone aggregate 20mm nominal size) .

5.07 NS AR-03 Providing and fixing in position 50 mm thick armor board of 32 - 36kg/m3 sqm 306.19 594.20 181,938
density in expansion joints at all heights and levels as shown in the drawing
and direction of Project Manager including cost of primer/adhesive etc.
complete.

Total of Subhead-5 - 50,973,805

6.00 SH-6 FORM WORK -


6.01 CPWD 5.9.1 Centering and shuttering for foundations, footings, bases of columns etc. for sqm 428.00 196.45 84,081
DSR 2014 mass concrete including strutting, propping, oiling, etc. removal of form work.

6.02 CPWD 5.9.2 Centering and shuttering for walls ( any thickness) including attached sqm 2,037.60 360.80 735,166
DSR 2014 pilasters, buttresses, plinth and string courses including strutting, propping,
oiling, etc. removal of form work.

6.03 CPWD 5.9.3 Centering and shuttering for suspended floors, roofs, landings, balconies and sqm 17,492.74 401.65 7,025,959
DSR 2014 access platform including strutting, propping, oiling, etc. removal of form
work.

6.04 CPWD 5.9.5 Centering and shuttering for lintels, beams, plinth beams, girders, bressumers sqm 11,662.22 332.15 3,873,606
DSR 2014 and cantilevers including strutting, propping, oiling, etc. removal of form
work.

62
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.05 CPWD 5.9.6 Centering and shuttering for columns, pillars, piers, abutments, posts and sqm 14,454.54 453.35 6,552,966
DSR 2014 struts including strutting, propping, oiling, etc. removal of form work.

6.06 CPWD 5.9.16.1 Centering and shuttering for edges of slabs and breaks in floors and walls Metre 90.00 116.40 10,476
DSR 2014 upto 20cm width including strutting, propping, oiling, etc. removal of form
work.

6.07 CPWD 5.11.1 Extra for additional height in centering, shuttering wherever required for sqm 5,045.00 159.05 802,407
DSR 2014 suspended floors, roofs, landings, beams and balconies ( plan area to be
measured ) with adequate bracing, propping etc. including cost of de-
shuttering and de-centering at all levels, over a height of 3.5m, for additional
height of 1 Metre or part thereof ( plan area to be measured )

Total of Subhead-6 - 19,084,661

7.00 SH-7 STEEL REINFORCEMENT WORK

7.01 UPPWD Derived Providing and fixing Thermo-mechanically treated MS bars reinforcement for kg 457,110.00 68.90 31,494,879
SOR 2014 from 504 R.C.C. work including straightening, cutting, bending, placing in position and
binding complete upto plinth level. - Fe 500

7.02 UPPWD Derived Providing and fixing Thermo-mechanically treated MS bars reinforcement for kg 717,930.00 68.90 49,465,377
SOR 2014 from 504 R.C.C. work including straightening, cutting, bending, placing in position and
binding complete above plinth level. - - Fe 500

Total of Subhead-7 - 80,960,256

8.00 SH-8 BRICK WORK


8.01 UPPWD 303 First class brick work in 1:6 cement and fine sand of 1.25 fineness modulus cum 142.51 4,850.00 691,174
SOR 2014 mortar in foundation and plinth including supply of all materials, labour and
tools and plants etc. required for proper completion of the work.

63
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.02 UPPWD 310 As in item (303) above but in super structure above including necessary cum 1,981.32 5,050.00 10,005,666
SOR 2014 cutting and moulding of brick work as required and also including honey
combed brick in thickness of wall of one brick thick add for extra labour.

First floor -

8.2.1 UPPWD note Increase in As in item (303) above but in super structure above including cum 113.28 50.50 5,721
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Second floor -
8.2.2 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.14 101.00 11,326
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Third floor -
8.2.3 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.14 151.50 16,989
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fourth floor -
8.2.4 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.14 202.00 22,652
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fifth floor -
8.2.5 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 252.50 28,505
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Sixth floor -

64
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.2.6 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 303.00 34,206
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Seventh floor -

8.2.7 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 353.50 39,907
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Eighth floor -

8.2.8 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 404.00 45,608
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Ninth floor -
8.2.9 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 454.50 51,309
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Tenth floor -
8.2.10 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 505.00 57,009
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Eleventh floor -
8.2.11 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 555.50 62,710
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Twelveth floor -
8.2.12 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 606.00 68,411
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Thirteenth floor -

65
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.2.13 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 656.50 74,112
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Fourteenth floor -
8.2.14 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 707.00 79,813
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Fifteenth floor -

8.2.15 UPPWD note Increase in As in item (303) above but in super structure above including cum 112.89 757.50 85,514
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Sixteenth floor -

8.2.16 UPPWD note Increase in As in item (303) above but in super structure above including cum 117.64 808.00 95,053
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Seventeenth floor -
8.2.17 UPPWD note Increase in As in item (303) above but in super structure above including cum 59.28 858.50 50,892
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
8.03 CPWD 6.12.2 Half brick masonry in cement mortar 1:4 ( 1 cement : 4 coarse sand) in sqm 14.15 574.70 8,132
DSR 2014 foundation and plinth with common burnt clay F.P.S. (Non modular) bricks of
class designation 7.5.

8.04 UPPWD 310(a) As in item (303) above but in super structure above including necessary cum 714.68 5,150.00 3,680,602
SOR 2014 cutting and moulding of brick work as required and also including honey
combed brick in thickness of wall of half brick (4.1/2")thick. Add for extra
labour over item no. 310 of one brick thick add for extra labour.

First floor -

66
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.4.1 UPPWD note Increase in As in item (303) above but in super structure above including cum 46.24 51.50 2,381
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Second floor -

8.4.2 UPPWD note Increase in As in item (303) above but in super structure above including cum 49.35 103.00 5,083
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Third floor -

8.4.3 UPPWD note Increase in As in item (303) above but in super structure above including cum 49.35 154.50 7,625
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Fourth floor -
8.4.4 UPPWD note Increase in As in item (303) above but in super structure above including cum 49.35 206.00 10,166
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fifth floor -

8.4.5 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 257.50 11,412
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Sixth floor -

8.4.6 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 309.00 13,695
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Seventh floor -

67
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.4.7 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 360.50 15,977
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Eighth floor -

8.4.8 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 412.00 18,260
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Ninth floor -

8.4.9 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 463.50 20,542
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Tenth floor -

8.4.10 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 515.00 22,825
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Eleventh floor -

8.4.11 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 566.50 25,107
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Twelveth floor -

8.4.12 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 618.00 27,390
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Thirteenth floor -
8.4.13 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 669.50 29,672
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

68
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Fourteenth floor -
8.4.14 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 721.00 31,955
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Fifteenth floor -

8.4.15 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.32 772.50 34,237
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Sixteenth floor -
8.4.16 UPPWD note Increase in As in item (303) above but in super structure above including cum 14.48 824.00 11,932
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Seventeenth floor -

8.4.17 UPPWD note Increase in As in item (303) above but in super structure above including cum 14.62 875.50 12,800
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

8.05 CPWD 6.15 Extra for providing and placing in position 2 nos. 6mm dia M.S. bars at every sqm 6,214.57 69.50 431,913
DSR 2014 third course of half brick masonry with FPS bricks in superstructure above
plinth level up to floor V level

Total of Subhead-8 - 15,948,283

9.00 SH-9 WATER-PROOFING OF RAFT, RETAINING WALL, DECK SLAB, ROOFS,


INTERNAL WET AREAS
BASEMENT & UNDERGROUND STRUCTURES WATER-PROOFING - -

RAFT & VERTICAL SURFACES - -

69
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Waterproofing of Raft: -
9.01 NS AR-05 Supplying and installing membrane waterproofing treatment for Raft Slab , sqm 4,728.26 1,987.21 9,396,046
1.2mm thick fully bonded HDPE sheet membrane "Preprufe 300 R " or
equivalent approved make before casting of base RCC slab. The pre-
applied, fully bonded HDPE sheet membrane gets bonded to the
underneath of the poured concrete used as base/ raft slab. The fully bonded
HDPE sheet membrane shall consist of a thick HDPE film, a highly aggressive
pressure sensitive adhesive and weather resisting coating which bonds
integrally to poured concrete of base slab. The membrane shall be BBA
certified and conforms to basement waterproofing protection to grades 2, 3
as defined in BS 8102:2009. The fully bonded HDPE sheet waterproofing
membrane shall have following minimum properties : 1) Resist hydrostatic
pressure of upto 70 m head of water as per ASTM D5385; 2) Puncture
Resistance of 990 N 3) Adhesion to concrete of 2.88 N/mm. The fully bonded
HDPE sheet membrane, shall be installed with standard 75mm side edge laps
and 75mm end laps taped with Tape HC, a double side coated adhesive
tape over the entire area and turned up on to a vertical timber. The
membrane shall be laid over the concrete blinding having smooth dried
surface including necessary removal of release liner while applying,
necessary overlaps between the membranes and fixing overlaps by Tape,
firm rolling onto the surface to get a tight seal, etc. All systems to be installed
as per approved manufacturer's recommendations, etc. complete with all
lead and lift for all materials and labour and as directed by Engineer in-
charge. Refer drawing.

Waterproofing treatment to Construction joints in walls / floors -

9.02 CPWD 22.4.1 providing and placing in position suitable PVC water stops Serrated with Metre 305.41 490.20 149,712
DSR 2014 central bulb ( 225 mm wide, 8-11 mm thick) conforming to IS : 12200 of Deep
Jyoti or equivalent for construction / expansion joints between two RCC
members and fixed to the reinforcement with binding wire before pouring
concrete etc. complete.

70
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Waterproofing of Retaining Wall: -

9.03 NS AR-08 Supplying and Installing self adhesive, cold applied , flexible 1.5mm thick sqm 1,420.16 1,284.48 1,824,167
waterproofing membrane " Bituthene 8000" or equivalent approved make
comprising of a self adhesive rubberized asphalt with cross laminated HDPE
film with a unique solar reflective film on top surface . The membrane shall
have pre-marked overlaps of 50mm and shall be applied on the uniform
concrete surface. The self adhesive membrane shall be BBA certified and
confirm to all grades of BS 8102:2009 and shall have following minimum
properties : (i)  Puncture resistance of 290N (ii) Resistance to Hydrostatic
head of 70m (ASTM D 5385) (iii) Should be resistant to Sulphates, Nitrates and
salt in soil. For membrane termination: Make 25mm x 25mm chase/rebate on
the vertical wall for termination of the membrane. The chase/rebate shall be
adequately sealed with approved material. All systems to be installed as per
approved manufacturer's recommendations, etc. complete with all lead
and lift for all materials and labour and as directed by Engineer in-charge as
per drawings. system shall be guaranteed for 10 years on Rs 100/- stamp
paper.

9.04 NS AR-09 Providing and fixing HDPE protection board on vertical surfaces with sqm 1,420.16 230.00 326,637
adhesives i/c cost of overlaps @ 10% as protection of waterproofing.

SUNKEN AREA WATERPROOFING - -

9.05 CPWD 22.5 Providing and laying water proofing treatment in sunken portion of WCs, sqm 1,256.06 283.10 355,591
DSR 2014 bathroom etc., by applying cement slurry mixed with water proofing cement
compound consisting of applying : (a) Ist layer of slurry of cement @ 0.488
kg/sqm mixed with water proofing compound @0.253 kg/per sqm. This layer
will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @
0.242 kg/sqm mixed with water proofing compound @0.126 kg/sqm. This
layer will be allowed to air cure for 4 hours followed with water curing for 48
hours. The rate includes preparation of surface, treatment and sealing of all
joints, corners, junction of pipes and masonry with polymer mixed slurry.

9.06 CPWD 13.6.1 20 mm cement plaster of mix Cement mortar 1:4. to protect the sqm 1,256.06 242.05 304,029
DSR 2014 waterproofing

71
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ROOF WATERPROOFING -
9.07 CPWD 22.7.1 Providing and laying integral cement based water proofing treatment sqm 1,628.28 1,019.05 1,659,299
DSR 2014 including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations: a) Applying a slurry
coat of neat cement using 2.75 kg/sqm of cement admixed with water
proofing compound conforming to IS. 2645 and approved by Engineer-in-
charge over the RCC slab including adjoining walls upto 300 mm height
including cleaning the surface before treatment. b) Laying brick bats with
mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of
cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge
over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand
) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and treating similarly the
adjoining walls upto 300 mm height including rounding of junctions of walls
and slabs
c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the
surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing compound conforming to IS :
2645 and approved by Engineer-in-charge including laying glass fibre cloth
of approved quality in top layer of plaster and finally finishing the surface
with trowel with neat cement slurry and making pattern of 300x300mm
square 3 mm deep. e) The whole terrace so finished shall be flooded with
water for a minimum period of two weeks for curing and for final test. All
above operations to be done in order and as directed and specified by the
Engineer-in-Charge :..With average thickness of 120 mm and minimum
thickness at khurra as 65 mm.

9.08 NS AR-14 Providing and fixing aluminum flashing , wherever required for termination of Metre 534.52 495.00 264,587
Bituthene membrane at all locations . Item shall include rates for membrane
termination on the Vertical parapet wall at height as specified in drawings
for termination of the membrane.

72
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Waterproofing Treatment for Landscaping Decks and Landscape Roofs -

9.09 CPWD 22.19 Providing and laying APP (Atactic Polypropylene Polymer) modified sqm 3,178.84 407.50 1,295,377
DSR 2014 prefabricated five layer, 3mm thick water proofing membrane, black finished
reinforced with glass fibre matt consisting of a coat of bitumen primer for
bitumen membrane @ 0.40ltr/sq.mt by the same membrane manufactured
of density @25°C, 0.87-0.89 kg/litre and viscosity 70-160 cps. Over the primer
coat the layer of membrane shall be laid using Butane torch and sealing all
joints etc. and preparing the surfaces complete. The vital physical and
chemical parameters of the membrane shall be - Joint strength in
longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength
in longitudinal and transverse direction as 60/80N. Softening point of
membrane not less then 150° C. cold flexibility shall be upto -2°C when tested
in accordance with ASTM, D_5147. The laying of membrane shall be got
done through the authorized applicator of the manufacturer of membrane.

9.10 CPWD 22.21 Extra for covering top of membrane with Geotextile, 120gsm non Woven, sqm 3,178.84 74.85 237,936
DSR 2014 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with
intermitted touch by heating the membrane by Butane torch as per
manufacturers recommendation [ for the item No. 22.18 to 22.20 ]

Protection on Terrace Waterproofing -

9.11 CPWD 4.20.2.1 Providing and laying in position ready mix plain cement concrete M15 cum 360.53 6,540.90 2,358,191
DSR 2014 GRADE , with cement content as per approved design mix and manufacture
in fully automatic batching plant and transported to site of work in transit
mixer for all leads, having continuous agitated mixer, manufactured as per
mix design of specific grade for plain cement concrete work, including
pumping of RMC from transit mixer to site of laying i/c curing excluding cost
of centering and shuttering and finishing i/c cost of curing, admixtures in
recommended portion as per IS 9103 to accelerate / retard setting of
concrete , improve workability without impairing strength and durability as
per the directions of engineer in charge. MINIMUM CEMENT 240 all work
above plinth level upto level 5.

73
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.12 CPWD 22.14.1 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cum 81.41 5,570.55 453,498
DSR 2014 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size )

9.13 CPWD 12.22 Making khurras 45x45cm with average minimum thickness of 5cm cement each 26.00 186.65 4,853
DSR 2014 concrete 1:2:4 over PVC sheet 1mx1m x 400, micron finished with 12mm
cement plaster 1:3 and one coat of neat cement rounding of edges and
making and finishing the outlet complete.

Total of Subhead-9 - 18,629,923

10.00 SH10 INSULATION - OVERHEAD & UNDERDECK

10.01 CPWD 12.56 Providing and laying roof insulation with 40 mm thick impervious sprayed, sqm 1,467.92 1,167.20 1,713,356
DSR 2014 closed cell free Rigid Polyurethane foam over deck insulation conforming to
IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of
polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene
sheet over PUF spray and providing a wearing course of 40 mm thick cement
screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal
size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding
with 24 G wire netting and sealing the joints with polymerized mastic, all
complete as per direction of Engineer-in-Charge

Total of Subhead-10 - 1,713,356

11.00 SH-11 PLASTERING - INTERNAL AND EXTERNAL -

Wall plaster - -

11.01 UPPWD 586 12 mm thick plaster with cement mortar in proportion of 1:6 cement & fine sqm 12,821.72 109.00 1,397,567
SOR 2014 sand of 1.25 F.M.

11.02 CPWD 13.5.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:6 sqm 19,232.59 183.45 3,528,219
DSR 2014 ( 1 cement:6 coarse sand )

11.03 CPWD 13.5.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 sqm 5,384.95 183.45 987,869
DSR 2014 ( 1 cement:4 coarse sand ) in internal walls of service shafts

74
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Ceiling plaster - -

11.04 UPPWD 584+587 12mm cement plaster to ceiling of cement mortar mix 1:4 (1 cement : 4 fine sqm 13,036.51 137.00 1,786,002
SOR 2014 sand of 1.25 FM).

11.05 CPWD 5.30 Add or deduct for plaster drip course / groove in plastered surface or Metre 600.00 30.75 18,450
DSR 2014 moulding to RCC projections.

11.06 CPWD 13.11 18mm cement plaster in two coats under layer 12 mm thick cement plaster sqm 10,550.11 240.55 2,537,829
DSR 2015 1:5 ( 1cement:5 coarse sand ) finished with a top layer 6 mm thick cement
plaster 1:6 ( 1cement : 6 fine sand ).

11.07 CPWD 13.22 Extra for plastering exterior walls of height more than 10 m from ground level sqm 9,059.85 37.95 343,821
DSR 2014 for every additional height of 3 m or part thereof.

11.08 CPWD 4.18 Extra for addition of synthetic Polyester triangular fibre of length 12mm, per bag 2,110.00 53.00 111,830
DSR 2014 effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in of 50kg
cement concrete/RCC/Flooring/water retaining structures by using 125gms of cement
synthetic Polyester triangular fibre for 50 Kg cement used as per directions of
Engineer-in-Charge.

11.09 CPWD 7.23.2.5 30mm thick white sand stone work (machine cut edges) -exposed face Sqm. 2,638.00 3,036.60 8,010,551
DSR 2014 machine cut and table rubbed with rough backing for wall lining etc.
(veneer work) backing filled with a grout of 12 mm thick cement mortar 1:3
(1 cement :3 coarse sand) including pointing in with white cement mortar 1:2
( 1 white cement : 2 stone dust) with an admixture of pigment matching the
stone shade. ( To be secured to the backing by means of cramps shall be
paid for separately )

11.10 CPWD 7.32.2 White sand stone work, plain in copings, cornices, string course and plinth cum 2.14 39,022.00 83,507
DSR 2014 courses in cement mortar 1:6 ( 1 cement : 6 coarse sand) including pointing
with white cement pointing with white cement mortar 1:2 ( 1 white cement:2
stone dust) with an admixture of pigment matching the stone shade.

Total of Subhead-11 - 18,805,645

75
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

12.00 SH-12 STEEL WORKS

12.01 CPWD 10.25 Steel work welded in built up sections/ framed work including cutting, - -
DSR 2014 hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.

12.1.1 CPWD 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar kg 43,195.00 90.10 3,891,870
DSR 2014 works.

12.02 NS AR P/F Hollock wood hand rail for staircase size 65mm x 120mm fixed to mild Metre 1,727.78 857.20 1,481,053
steel flat with screws i/c spirit polishing after applying wood filler.

Total of Subhead-12 - 5,372,923

13.00 SH 13 EXTERNAL FAÇADE WORK - ALUMINIUM, GLASS , GLASS DOORS -

13.01 NS AR Design, fabrication and installation of anodised aluminium fixed louvers with sqm 195.00 1,722.00 335,790
tubular section and outer aluminium channel frame at terrace level with m.s.
supporting structure behind as shown in concept details. Aluminium frame,
necessary hardware like s.s. nuts / bolts, frame fixing screws etc. as per the
elevation, sections and details shall be used as per drawings enclosed. 'The
aluminium louvers shall be fabricated out of heavy duty aluminium extruded
built up profiles confirming to alloy 63400 WP with chemical composition and
mechanical properties as per IS:733:1983 and IS 1285:2002. All profiles shall be
anodised in approved shade. ( aluminium quantity payable in DSR item
21.1.1)

76
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.02 CPWD 26.1 Providing and supplying aluminium extruded tubular and other aluminium kg 1,901.25 338.25 643,098
DSR 2014 sections for louvers as per the architectural drawings and approved shop
drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS
1474,including anodising coating AC 15 microns conforming to AAMA 2604 of
required colour and shade as approved by the Engineer-in-Charge. ( The
item includes cost of material such as cleats, sleeves, screws etc. necessary
for fabrication of extruded aluminium frame work. Nothing extra shall be
paid on this account).

Total of Subhead-13 978,888

14.00 SH-14 WOOD WORK - DOORS, PARTITIONS & PANELING


14.01 CPWD 9.1.1 Providing Second class Teak wood work in frames of doors, windows, cum 2.14 91,496.90 195,803
DSR 2014 clerestory windows and other frames, wrought framed and fixed in position
with hold fast lugs or dash fastener of required dia and length ( hold fast lugs
or dash fastener shall be paid for separately).

14.02 CPWD 9.1.3 Providing Kiln seasoned and chemically treated Hollock wood work in cum 18.06 53,698.60 969,797
DSR 2014 frames of doors, windows, clerestory windows and other frames, wrought
framed and fixed in position with hold fast lugs or dash fastener of required
dia and length ( hold fast lugs or dash fastener shall be paid for separately).

14.03 CPWD 9.5.1.1 Providing and fixing 35mm thick second class teak wood panelled or sqm 85.34 2,689.05 229,484
DSR 2014 panelled and glazed shutters for doors, windows and clerestory windows
including ISI marked M.S. pressed butt hinges bright finished of required size
with necessary screws excluding paneling which will be paid separately, all
complete as per direction of Engineer-in-charge.

14.04 CPWD 9.7.3.1 Providing and fixing 9mm thick decorative plywood both side decorative sqm 85.34 1,863.00 158,988
DSR 2014 veneer ( type I) conforming to IS 1328 BWR type paneling in panelled or
panelled and glazed shutters for doors, windows and clerestory windows (
area of opening for panel inserts excluding portion inside grooves or rebates
to be measured) .

77
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
14.05 CPWD 9.20.1 Providing and fixing 35mm thick ISI marked flush door shutter confirming to IS sqm 712.46 2,606.45 1,856,991
DSR 2014 : 2202 ( part I) decorative type, core of block board construction with frames
of first class hard wood and well matched teak 3 ply veneering with vertical
grains or cross bands and face veneers on both sides of shutters fixed with ISI
marked stainless steel butt hinges with necessary hinges.

14.06 CPWD 9.23 Extra for providing lipping with second class teak wood battens 25mm sqm 712.46 365.85 260,653
DSR 2014 minimum depth on all edges of shutters ( over all area of door shutter to be
measured ).

14.07 CPWD 9.40.1.1 Providing and fixing 2nd class teak wood size 50x12 mm moulded beading metre 2,442.14 117.95 288,050
DSR 2014 to door and window frames with iron screws, plugs and priming coat on
unexposed surface etc. complete.

14.08 CPWD 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with each 1,928.00 117.35 226,251
DSR 2014 10 mm diameter bolts, nuts and wooden plugs and embedding in cement
concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded
stone aggregate 20mm nominal size)

14.09 CPWD 9.14 Extra for providing ISI marked stainless steel butt hinges instead of black sqm. 85.34 253.50 21,634
DSR 2014 enameled M.S. butt hinges with necessary screws. ( shutters Area shall be
measured)

14.10 CPWD 17.31 Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of each 190.00 793.25 150,718
DSR 2014 approved quality) complete with 6 mm thick hard board ground fixed to
wooden cleats with C.P. brass screws and washers complete.

14.11 CPWD 10.27.3 Providing and fixing 10 x 120 mm carbon steel galvanised ( minimum coating each 50.00 86.75 4,338
DSR 2014 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield
strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide
PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry,
etc. as per direction of Engineer-in-charge.

Total of Subhead-14 4,362,707

78
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.00 SH-15 FLOORING, SKIRTING & DADO WORK
15.01 CPWD 11.6.1 Providing and laying 18mm thick Cement plaster skirting (up to 30 cm height) sqm 40.72 377.25 15,362
DSR 2014 with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating
coat of neat cement.

15.02 CPWD 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and sqm 2,229.81 1,141.40 2,545,105
DSR 2014 jointed with grey cement slurry mixed with pigment to match the shade of
the slab, including rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) : 25mm thick

15.03 CPWD 11.41 Providing and laying polished vitrified floor tiles in different sizes (thickness to -
DSR 2014 be specified by the manufacturer) with water absorption's less than 0.08%
and conforming IS : 15622 of approved make in all colours and shades, laid
on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) including
grouting the joints with white cement and matching pigments etc. complete.

15.3.1 CPWD 11.41.2 Size of tiles 60x60cm sqm 6,249.00 1,405.95 8,785,782
DSR 2014
15.04 CPWD 16.86.1 Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded sqm 3,247.39 3,148.55 10,224,570
DSR 2014 and pre polished machine cut granite stone of required size and shape of
approved shade, colour and texture in footpath, flooring cut granite stone of
required size and shape of approved shade, colour and texture in footpath,
flooring in road side plazas and similar locations, laid over 20mm thick base
of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints
with white cement mixed with matching pigment, epoxy touch ups etc.
complete as per direction of Engineer-in-Charge. stone size Area less than
0.50 sqm. ( Granite rate Rs. 1900 per sqm tax paid)

15.05 CPWD 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy
DSR 2014 grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of
hardener and 0.20 kg of resin per kg), including filling / grouting and finishing
complete as per direction of Engineer-in-charge.

15.5.1 CPWD 11.48.2 Size of Tile 600x600 mm sqm 6,249.00 187.95 1,174,500
DSR 2014

79
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.06 CPWD 11.37 Providing and laying ceramic glazed floor tiles 300x300mm in size ( thickness sqm 1,260.01 785.40 989,612
DSR 2014 to be specified by the manufacturer) of Ist quality confirming to IS : 15622 of
approved make in colours such as white, Ivory , grey , fume red brown laid
on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) including
pointing the joints with white cement and matching pigments etc. complete

15.07 CPWD 11.25 Extra for granite stone flooring in treads of steps and risers using single length sqm 73.88 320.30 23,664
DSR 2014 up to 2.00 metre.

15.08 CPWD Derived Providing and fixing 18mm thick granite in skirting, riser, sills etc. for vertical sqm 290.10 3,431.00 995,333
DSR 2014 surfaces of approved quality and shade laid over 12/15mm(AV.) thick cement
mortar 1:4 (1 cement:4 coarse sand) and jointed with white cement slurry
mixed with pigment to match the granite shade etc. all complete.

15.09 NS AR Extra for making honed finish surface of granite in treads instead of polished. sqm 73.88 223.57 16,517

15.10 CPWD 11.46 Providing and laying polished vitrified tiles in different sizes (thickness to be -
DSR 2014 specified by the manufacturer) with water absorption's less than 0.08% and
conforming IS : 15622 of approved make in all colours and shades, in skirting,
risers of steps, laid with 12mm thick cement mortar 1:3 ( 1 cement : 3 coarse
sand) including grouting the joints with white cement and matching
pigments etc. complete.

15.10.1 CPWD 11.46.2 Size of tiles 60x60cm in dado sqm 511.28 1,415.40 723,666
DSR 2014
15.11 CPWD 11.27 Providing and laying 25mm thick Kota stone slabs in skirting, dado, pillars, sqm 600.15 1,191.25 714,929
DSR 2014 risers of steps (area upto 900 sqcm) laid on 12mm thick (Avr) cement mortar
1:3 ( 1 cement : 3 coarse sand) and jointed with grey cement slurry mixed
with pigment to match the shade of stone slabs, including necessary cutting,
rubbing and polishing etc. complete.

80
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.12 CPWD 11.36 Providing and fixing Ist quality ceramic glazed wall tiles conforming to sqm 4,866.11 836.65 4,071,231
DSR 2014 IS:15622 (thickness to be specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white
cement mixed with pigment of matching shade complete

15.13 CPWD 8.2.1.2 Providing and laying 18mm thick mirror polished, machine cut marble for sqm 450.67 2,463.55 1,110,248
DSR 2014 kitchen platforms, vanity counters, facias, windows sills and similar locations
of required size of approved shade, colour and texture laid over 20mm thick
base cement mortar 1:4 ( 1 cement : 4 coarse sand) with joints treated with
white cement mixed with matching pigment, epoxy touch ups including
rubbing, curing etc. complete at all levels. Raj Nagar plain white marble/
Udaipur green marble/ Zebra black marble -Area of slab over 0.5 sqm

15.14 CPWD 8.2.2.2 Providing and laying 18mm thick mirror polished, machine cut for kitchen sqm 157.67 3,907.40 616,080
DSR 2014 platforms, vanity counters, facias and similar locations of required size of
approved shade, colour and texture laid over 20mm thick base cement
mortar 1:4 ( 1 cement : 4 coarse sand) with joints treated with white cement
mixed with matching pigment, epoxy touch ups including rubbing, curing
etc. complete at all levels. granite of any colour and shade -Area of slab
over 0.5 sqm

15.15 CPWD 8.3.1 Providing edge moulding to 18mm thick marble stone counters, vanities etc. metre 707.28 136.10 96,261
DSR 2014 including machine polishing to edge to give high gloss finish etc. complete
as per design approved by engineer in charge.

15.16 NS AR Extra for providing and fixing 12mm thick BW plywood behind marble / metre 727.28 191.27 139,107
granite fascia upto 200mm height to fix stone with Araldite adhesive

15.17 CPWD 8.4 Extra for fixing marble / granite stone over and above corresponding item in metre 727.28 247.40 179,929
DSR 2014 facia and drops of width upto 150mm with epoxy resin based ( Araldite or
equivalent) adhesive including cleaning etc. complete

81
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.18 CPWD 8.5 Extra for providing opening of required size & shape for wash basins / each 268.00 386.60 103,609
DSR 2014 kitchens sink in kitchen platform, vanity counters and similar location in opening
marble / stone work including necessary holes for pillar taps etc. including
rubbing and polishing of cut edges etc. complete.

15.19 CPWD 11.32 Extra for Kota stone/sand stone in treads of steps and risers using single length sqm 490.05 16.90 8,282
DSR2014 up to 1.05 metre.

15.20 CPWD derived Providing and fixing granite Stone work for wall lining upto 10 m height with sqm 2,420.46 3,070.00 7,430,812
DSR 2014 from 7.38 special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand), including pointing in white cement with an admixture of
pigment to match the stone shade.

15.21 CPWD 11.53 Providing and fixing Glass mossaic tiles at finished plain wall surface of size sqm 55.50 1,752.60 97,269
DSR2014 20 mmx20 mmx4 mm in all colour, design, fixing in customize design as per
direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall
surface with the help of approved adhesive applied at the rate of 2.5 kg per
sqm and grouting of the same. The rate is inclusive of all operation, material
and required pattern approved by Engineer-in-Charge:

15.22 CPWD 16.75 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete cum 366.87 6,848.85 2,512,638
DSR 2014 from batching plant. The ready mixed concrete shall be laid and finished
with screed board vibrator , vacuum dewatering process and finally finished
by floating, brooming with wire brush etc. complete as per specifications
and directions of Engineer-in- charge. (The panel shuttering work shall be
paid for separately). (Note:- Cement content considered in this item is @ 330
kg/cum. Excess/less cement used as per design mix is payable/ recoverable
separately).

Total of Subhead-15 42,574,503

82
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
16.00 SH-16 FALSE CEILING WORKS
16.01 CPWD 12.45 Providing and fixing at all height false ceiling including providing and fixing -
DSR 2014 of frame work made of special sections power pressed from M.S. sheet and
galvanised in accordance with zinc coating of grade 350 as per IS: 277 and
consisting of angle cleats of size 25mm wide x 1.6 mm thick with flanges of
22mm and 37mm at 1200mm center to center one flange fixed to the ceiling
with dash fastener 12.5mm dia x 40mm long with 6mm dia bolts to the angle
hangers of 25x25x0.55 mm of required length and other end of angle hanger
being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the
rate of 1200 mm center to center to which the ceiling section 0.5 mm thick
button wedge of 80 mm with tapered flanges of 26 mm each having clips of
10.5 mm at 450 mm center to center shall be fixed in a direction
perpendicular to G.I. channel with connecting clips made out of 2.64 mm
dia x230mm long G.I. wire at every junction including fixing the gypsum
board with ceiling section and perimeter channels 0.5 mm thick 27 mm high
having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450 mm center to center with 25
mm long drive all screws @ 230 mm interval including jointing and fixing to a
flush finish of tapered and square edges of the board with recommended
filler, jointing tapes, finisher and two coats of primer suitable for board as per
manufactures specification and also including the cost of making openings
for light fittings ,grills, diffusers, cutouts made with frame of perimeter
channels suitably fixed all complete as per drawing and specification and
direction of the Engineer-in-charge but excluding the cost of painting with :

16.1.1 CPWD 12.45.1 12.5 mm thick tapered edge gypsum board conforming to IS: 2095 - part I. sqm 3,390.57 907.10 3,075,586
DSR 2014

16.1.2 CPWD 12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board. sqm 1,208.01 1,059.50 1,279,887
DSR 2014

16.02 NS AR Providing and fixing Trap door in ceiling made of 12mm thick BWR plywood sqm 75.00 1,802.49 135,187
fixed to hardwood framing with SS but hinges with SS screws.

Total of Subhead-16 4,490,659

83
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
17.00 SH-17 WALL FINISHES - INTERNAL & EXTERNAL

17.01 CPWD 13.26 Providing and applying plaster of Paris putty of 2mm thickness over plastered sqm 20,684.55 110.95 2,294,951
DSR 2014 surface to prepare the surface even and smooth complete.

17.02 CPWD 13.37.1 White washing with lime to give an even shade, New work ( three or more sqm 5,384.95 16.20 87,236
DSR 2014 coats ).

17.03 CPWD 13.45.1 Finishing walls with textured exterior paint of required shade: New work ( two Sqm. 3,638.52 146.45 532,861
DSR 2014 or more coats applied @ 3.28 litre/10 sqm) over and including base coat of
water proofing cement paint applied @ 2.20kg/10sqm.

17.04 CPWD 13.68.1 French spirit polishing two or more coats on new works including a coat of sqm 249.91 193.95 48,470
DSR 2014 wood filler.

17.05 CPWD 13.81.2 Distempering two with 1st quality acrylic distemper, having VOC (Volatile sqm 36,107.00 45.70 1,650,090
DSR 2014 Organic Compound ) content less than 50 grams/ litre, of approved brand
and manufacture, including applying additional coats wherever required, to
achieve even shade and colour.

17.06 CPWD 13.84.2 Painting with two coats synthetic enamel paint, having VOC (Volatile sqm 2,477.05 71.60 177,357
DSR 2014 Organic Compound) content less than 150 grams/ litre, of approved brand
and manufacture, including applying additional coats wherever required to
achieve even shade and colour.

17.07 CPWD 13.85.2 Applying priming coats With ready mixed red oxide zinc chromatic on steel / sqm 2,477.05 30.80 76,293
DSR 2014 iron works having VOC content less than 250 grams/litre on wood work (hard
and soft wood) of approved brand and manufacture.

17.08 CPWD 14.70 Melamine polishing on wood work (one or more coats). Sqm. 249.91 76.70 19,168
DSR 2014
17.09 NS AR Providing and applying of 2 coats of exterior Metallic paint of approved sqm 4,274.06 270.00 1,153,996
shade in silver finish i/c applying wall care putty, exterior wall primer on walls
as per specifications complete.

Total of Subhead-17 6,040,422

84
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

18.00 SH-18 ALUMINIUM WORK - DOOR, WINDOWS

18.01 CPWD 21.1 Providing, fixing, supplying, installation and design of aluminium work for -
DSR 2014 doors, windows, ventilators and partitions with extruded built up standard
tubular sections/appropriate Z sections and other sections of approved
make confirming to IS: 733 and IS: 1285 fixed with rawl plugs and screws or
with fixing clips or with expansion hold fasteners including necessary filling up
of gaps at junctions, at top , bottom and sides with required PVC / neoprene
felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including cleat angle, aluminium
snap beading for glazing / paneling, CP brass / SS screws all complete as per
architectural drawings and the direction of Engineer-in-charge.(Glazing and
paneling to be paid for separately):

18.1.1 CPWD 21.1.1.1 Fixed Windows -Anodised aluminium (anodised transparent or dyed to kg 2,826.00 348.50 984,861
DSR 2014 required shade according to IS: 1868, Minimum anodic coating of grade AC
15)

18.1.2 CPWD 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade kg 29,749.00 405.90 12,075,119
DSR 2014 according to IS: 1868, Minimum anodic coating of grade AC 15) -For shutters
of doors, windows & ventilators including providing and fixing hinges/ pivots
and making provision for fixing of fittings wherever required including the
cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for
separately)
18.02 CPWD 21.8.1 Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone metre 11,460.00 88.75 1,017,075
DSR 2014 work Upto 5mm depth and 5 mm width by providing weather silicon sealant
over backer rod of approved quality as per architectural drawings and
direction of Engineer-in-charge.

18.03 CPWD 21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium sqm 3,570.00 3,487.10 12,448,947
DSR 2014 windows ,ventilators and partition etc, with 6 mm thick clear float glass both
side having 12 mm air gap including providing EPDM gasket, perforated
aluminium spacers, desiccants, sealant (both primary an secondary sealant)
etc. as per specifications, drawings and direction of Engineer-in-charge
complete.
18.04 CPWD 21.11.3 Providing and fixing stainless steel ( SS304 grade ) adjustable friction windows each 150.00 350.70 52,605
DSR 2014 stays 355 x 19 mm of approved quality with necessary stainless steel screws
etc. to the side hung windows as per direction of Engineer-in-charge
complete.

85
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
18.05 CPWD 21.11.2 Providing and fixing stainless steel ( SS304 grade ) adjustable friction windows each 360.00 275.25 99,090
DSR 2014 stays 255 x 19 mm of approved quality with necessary stainless steel screws
etc. to the side hung windows as per direction of Engineer-in-charge
complete.
18.06 CPWD derived Providing and fixing double glazed hermetically sealed glazing in aluminium sqm 3,364.00 3,883.45 13,063,926
DSR 2014 21.1 windows ,ventilators and partition etc, GL10 with 5 mm thick toughened clear
float glass outer side having 10 mm air gap 4mm thick clear toughened glass
inner including providing EPDM gasket, perforated aluminium spacers,
desiccants, sealant (both primary an secondary sealant) etc. as per
specifications, drawings and direction of Engineer-in-charge complete.

18.07 CPWD 21.3.2 Providing and fixing 6mm clear float glass glazing in aluminium doors, sqm 177.00 1,054.20 186,593
DSR 2014 window, ventilators, shutters and partition etc. with PVC / neoprene gasket
etc. complete as per architectural drawing and the direction of the Engineer-
in-charge. ( cost of aluminium snap beading shall be paid in basic items.)

18.08 CPWD derived DSRExtra for toughening of 4/5/6mm thick clear glass pane sqm 177.00 290.40 51,401
DSR 2014

18.09 CPWD 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to kg 4,527.00 312.20 1,413,329
DSR 2014 required shade according to IS: 1868, Minimum anodic coating of grade AC
15) sub frame work for windows and ventilators with extruded built up
standard tubular sections of approved make conforming to IS: 733 and IS:
1285 fixed with rawl plugs and stainless steel screws etc.

18.10 CPWD 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of sqm 7.44 4,746.25 35,312
DSR 2014 approved brand and manufacture, including providing and fixing top &
bottom pivot & spring type fixing arrangement and making necessary holes
etc. for fixing required door fittings, all complete as per direction of Engineer-
in-charge (Door handle, lock and stopper etc.to be paid separately).

18.11 CPWD 10.29.2 Providing & fixing fly proof Wire gauze with stainless steel ( grade 304 ) wire Sqm 2,017.80 1,277.60 2,577,941
DSR 2014 gauze of 0.5mm dia wire and 1.4 mm aperture on both sides to windows,
clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.

Total of Subhead-18 44,006,200

86
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.00 SH-19 FIRE DOORS & ACCESSORIES
19.01 NS AR Supply and fixing of 2nd class teakwood - door frame of section 120 mm x 70 metre 220.10 1,431.00 314,963
mm with heat activated intumescent fire seal strip of section 10 mm x 4 mm 2
no. of Sealz, Fire & Acoustic , Viper make . The frame is duly primer with FR
retardant primer FR880 type primer and FR Paint FRS type. The frame should
be fixed in existing opening with thr help of anchor fastener of appropriate
size as per direction of Engineer in Charge. The manufacturer should be an
ISO certified and IGBC registered member. The approved manufacturer are
Navair , Promat , Godrej , Shakatimet .

19.02 NS AR Providing and fixing of 52mm thick Wooden fire rated door shutters tested as sqm 82.95 5,681.00 471,239
per BS:476 Part- 20 & 22 & IS 3614 Part-2 for stability, integrity and thermal
insulation. Recommended fire door shall have doors tested at CBRI vide test
report FR No. 0291 for maximum rating of 2hrs tested either with or without
vision panel. Individual Test certificates should be available for glass used in
vision lites confirming the required fire ratings. The shutter should be
maximum 52 mm thick upto commercial ply facing and lamination , if
required should be over and above . The core insulation should be asbestos
free comprising of two 12 mm thick Calcium Silicate boards of Pamtech
type , a 100% without Asbestos, having density not more than 900Kg/M3 and
thermal conductivity 0.14 W/m*K with non-combustibility as per BS 476 part 4-
1970 and class-1 surface spread as per BS-476 Part-7-1971 . These boards
sandwiching 20 mm thick fire resistance insulation filler faced with 03 mm
thick commercial ply facing on both faces .. the shutter is provided with heat
activated intumescent fire seal strip of size 20mm x 4 mm mounted in the
grooves of 2nd class teak wood Exposed lipping on all sides except bottom.
The intumescent fire retardant sealant should be used to fill the gaps
between civil opening and frame along with wool insulation so as to fill any
visible gap . The manufacturer should submit desired design test report for a
design tested earlier for 120 minutes fire rating along with Vision Panel tested
at CBRI Roorkee as per direction's of Engineer in Charge. The manufacturer
should be an ISO certified and IGBC registered member. The approved
manufacturer are Navair , Promat , Godrej , Shakatimet .

19.03 NS AR Supply & fixing of SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with each 168.00 361.00 60,648
SS Screws of BB1953 Becker F.S / 3090F DORMA / 8011008 GEZE Make ( 4 Nos
per panel ) (Required For All Doors)

87
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.04 NS AR Supply and fixing of Interlayered FR Glass of Saint-Gobain, Torch, Glaberwel each 42.00 6,998.00 293,916
make minimum 11 mm thick interlayered , 120 minutes fire Rated (EW120, EI
15 minutes ) Non Wired, Toughened Interlayered Glass of approved make
which can also withstand thermal shock upto 800 degree centigrade shall be
used as a glazing (Vision Panel Top/side fixed glazing) and is to be fixed in
between the glass beading by using ceramic fiber in accordance with BS :
476 Part 22/ EN 1363 EN 1364 for stability and integrity of size 300 mm x 500mm
(Clear vision ) and the manufacturer should have tested the glass of similar or
bigger size with any type of door framing from CBRI Roorkee . The Location of
the Fr Glass will be as per the directions of Engineer-in-charge ( Actual Glass
size will be measured for payment).

19.05 NS AR Supply & fixing of SS D Type Pull Handle of size 300mm mm Long of PHD2230 each 84.00 550.00 46,200
Becker F.S/ 8133006 GEZE/ TGDI30022 DORMA Make.

19.06 NS AR Supply & fixing of door closers of BLC-0408 Becker F.S/ TS-73V DORMA / TS2000 each 42.00 4,260.00 178,920
GEZE Make. (Required For All Fire Door)

19.07 NS AR Supply & fixing of anchor fasteners of HILTI/ FISHER/ Equivalent of maximum each 378.00 97.00 36,666
120mm length.

19.08 CPWD 13.58 Providing and applying two coats of fire retardant paint unthinned on sqm 165.90 247.65 41,085
DSR 2014 cleaned wood/ply surface @ 3.5 sqm per litre per coat including
preparation of base surface as per recommendations of manufacturer to
make the surface fire retardant.

19.09 NS AR Providing and fixing hollow metal doors with frames type profile B consisting sqm 426.22 6,500.00 2,770,430
of press metal frame of galvanised steel sheet1.6mm thick zinc coated fixed
with galvanised expansion shield and flat head machine screws 9mm dia
and min 75mm long. The shutter to be 46mm thick fabricated from 2 outer
sheets 1.2mm thick of galvanised sheet steel zinc coated i/c applying spray
coat of epoxy primer on all surfaces of frames and shutters and panels , dry
thickness not less than 35 microns.

19.10 NS AR P/F mortice shaft dead bolt with key with BS 57mm and 25mm sq. forend with each 90.00 900.00 81,000
escutcheons in SSS

Total of Subhead-19 4,295,067

88
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

20.00 SH20 STAINLESS STEEL & GLASS RAILING WORKS

20.01 CPWD 10.28 Providing and fixing stainless steel (Grade 304) railing (1.0m high from F.F.L. as kg 6,322.00 619.40 3,915,847
DSR 2014 per concept detail drawings) made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary stainless steel nuts
and bolts complete, i/c fixing the railing with necessary accessories &
stainless steel dash fasteners , stainless steel bolts etc., of required size, on the
top of the floor or the side of waist slab with suitable arrangement as per
approval of Engineer-in-charge, (for payment purpose only weight of
stainless steel members shall be considered excluding fixing accessories such
as nuts, bolts, fasteners etc.). Laminated glass shall be paid separately under
item.
20.02 NS AR Providing, fixing, supplying and installation of glass GL7 =6mm thick clear Metre 887.92 4,246.00 3,770,108
toughened glass + 1.52 mm thick PVB Lamination + 6mm. Thick clear
toughened glass as per approved ( 750mm in height glass), glass as per
approved sample fixed in position on to grade 304 S.S. balusters and
connectors with S.S. handrail as per concept detail drawings enclosed. 'The
item includes required holes, Labour, scaffolding, sales tax / VAT, excise duty
etc. complete in all respect. All S.S. items shall be paid separately.

Total of Subhead-20 7,685,955

21.00 SH21 HARDWARE FOR DOORS

21.01 CPWD 9.97.1 Providing and fixing 300x10mm size aluminum tower bolts ISI marked each 266.00 112.10 29,819
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete

21.02 CPWD 9.97.4 Providing and fixing 150x10mm size aluminum tower bolts ISI marked each 482.00 65.35 31,499
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete

89
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
21.03 CPWD 9.101.2 Providing and fixing aluminum hanging twin rubber floor door stopper ISI each 482.00 83.95 40,464
DSR 2014 marked anodised (anodic coating not less then grade AC 10 as per IS :1868
) transparent or dyed to required colour or shade with necessary screw etc.
complete

21.04 CPWD 9.113 Providing & fixing bright finished 100mm mortice lock with 6 levers without each 266.00 465.95 123,943
DSR 2014 pair of handles for aluminum door with necessary screws etc. complete (Best
make of approved quality) as per direction of Engineer-in-charge.

21.05 NS AR Providing and fixing Baby latch CP brass as per approved sample. each 216.00 120.00 25,920

21.06 NS AR P/F Magic eye as per approved sample each 180.00 100.00 18,000

Total of Subhead-21 269,644

22.00 SH22 EXTERNAL FAÇADE - GRC SCREENS, ALUMINIUM LOUVERS

22.01 NS AR Providing and Fixing of (Glass Fibre Reinforced Jali)GRC Jalli 50 mm thick of sqm 97.92 5,186.00 507,813
size, pattern, design, thickness and colour of approved make to be fixed
on/between RCC / Block work Column or structural steel work in vertical with
Dry Fixing method with all appropriate steel frame work , using appropriate
fasteners, and necessary hardware with scaffolding, etc in Building Façade.
The jali shall be made from 53 grade White Portland Cement . Super
Plasticizers, UV Resistant Synthetic inorganic pigments shall be used for
pigmentation. The jali shall be securely fixed with stainless steel bolts and
anchor fasteners(304 grade) of required size at specified locations. The rate
includes the cost of 50 mm thick Jali, SS brackets, anchor fasteners, SS sleeves
labour charges for fixing, required scaffolding etc. for all heights and leads.
The surface area of Jali shall be measured for payment.

90
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
22.02 CPWD 7.41 Providing and fixing structural steel frame ( for dry cladding with 30mm thick kg 2,000.00 143.55 287,100
DSR 2014 gang saw cut with machine cut edges sand stone ) on walls at all heights
using M.S. square / rectangular tube in the required pattern as per
architectural drawing including cost of cutting, bending, welding etc. The
frame work shall be supported in wall with the help of MS brackets / lugs of
angle iron / flats etc. which shall be welded to the frame and embedded in
brick wall with cement concrete block 1:2:4 ( 1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) of size 300x230x300mm
including necessary cost of centering and shuttering and with approved
expansion hold fasteners on CC / RCC surface including drilling necessary
holes. Approved cramps / pins etc. shall be welded to the frame work to
support stone cladding the steel work will be given a priming coat of Zinc
primer as approved by Engineer-in-charge and painted with two or more
coats of epoxy paint ( shop drawings shall be submitted by the contractor to
the Engineer-in-charge for approval before execution). The frame work shall
be fixed in true horizontal & vertical lines / planes. ( Only structural steel
frame work shall be measured for the purpose of payment, stainless steel
cramps shall be paid for separately and nothing extra shall be paid ).

Total of Subhead-22 794,913

23.00 SH-23 MISCELLANEOUS ITEMS


23.01 CPWD 59.2.2.1 Providing and fixing Aluminium fluted strips 3.15 mm thick sheet covering metre 160.40 330.05 52,940
DSR 2014 150mm wide over expansion joints with iron screws as per design.

91
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
23.02 CPWD 5.44.1 Providing and fixing of expansion joint system upto 100mm width related with metre 43.78 6,358.55 278,377
DSR 2014 floor location as per drawings and direction of Engineer-In-Charge. The joints
system will be of extruded aluminum base members, self aligning / self
centering arrangement and support plates etc. as per ASTM B221-02. The
system shall be such that it provides floor to floor /floor to wall expansion
control system for various vertical location in load application areas that
accommodates multi directional seismic movement without stress to it's
components. System shall consist of metal profiles with a universal aluminum
base member designed to accommodate various project conditions and
finish floor treatments. The cover plate shall be designed of width and
thickness required to satisfy projects movement and loading requirements
and secured to base members by utilizing manufacturer’s pre-engineered
self-centering arrangement that freely rotates / moves in all directions. The
Self – centering arrangement shall exhibit circular sphere ends that lock and
slide inside the corresponding aluminum extrusion cavity to allow freedom of
movement and flexure in all directions including vertical displacement.
Provision of Moisture Barrier Membrane in the Joint System to have watertight
joint is mandatory requirement all as per the manufactures design and as
approved by Engineer -in- Charge . (Material shall confirm to ASTM 6063.)

23.03 NS AR Supplying, drilling/ cleaning hole and injecting Hilti or equivalent ETA
approved HIT-RE 500 chemical with the help of Hilti HDM 500 dispenser, into a
hole of dia and depth as per manufacture's structural consultant
specifications and fixing rebar's of required diameters subsequently . The
chemical should be have successful usage in wet / water saturated concrete
/ diamond cored holes. The chemical should have approval against creep
and corrosion. Fixing methodology to be followed as per manufacturer
guidelines. Steel will be paid under separate head. Manufacturer to submit
rebar depth calculations basement on design loads and other parameters
as provided by Consultant and in accordance with EOTA - TR -023/029
guidelines for post installed rebar connection for approval.

23.3.1 NS AR 10mm Dia, rebar 150mm depth each 1,767.00 153.98 272,083
23.3.2 NS AR 12mm Dia, rebar 180mm depth each 1,060.00 308.00 326,480
23.3.3 NS AR 16mm Dia, rebar 240mm depth each 177.00 538.95 95,394
23.3.4 NS AR 20mm Dia, rebar 300mm depth each 88.00 1,047.00 92,136
23.3.5 NS AR 25mm Dia, rebar 375mm depth each 35.00 2,301.77 80,562

92
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
23.04 NS AR Supplying, drilling/ cleaning hole and fixing Hilti or equivalent make heavy -
duty ETA approved Toque controlled expansion HSL -3-B mechanical anchor
of appropriate size in concrete and fixing plates subsequently. The anchor
should be consist of 8.8 grade bolt with safety cap, washers, distance sleeve,
expansion sleeve, cone and a collapsible plastic section. All steel
components should be galvanised to minimum 5 microns. Red cap should
come out after required setting torque is applied for installation.
manufacturer should submit anchor design report based on design loads
and other parameters as provided by consultant. Metal anchors should be
designed in accordance with ETAG 001 annexure C guidelines for
anchorage of metal anchors for use in concrete. Application at site should
be done as per manufacturer guidelines.
23.4.1 NS AR M12 of standard length each 27.00 785.85 21,218
23.4.2 NS AR M16 of standard length each 27.00 1,468.56 39,651
23.4.3 NS AR M20 of standard length each 20.00 2,499.84 49,997
23.4.4 NS AR M24 of standard length each 27.00 3,294.28 88,946
23.05 CPWD 5.46.1 Providing and fixing of expansion joint system upto 100mm width of metre 9.00 6,358.55 57,227
DSR 2014 approved make and manufactures for various roof locations as per
approved drawings and direction of Engineer-In-Charge. The joints shall be
of extruded aluminum base members with, self aligning and self centering
arrangement support plates as per ASTM B221-02. The system shall be such
that it provides watertight roof to roof/roof to corner joint cover expansion
control system that is capable of accommodating multidirectional seismic
movement without stress to its components. System shall consist of metal
profile that incorporates a universal aluminum base member designed to
accommodate various project conditions and roof treatments. The cover
plate shall be designed of width and thickness required to satisfy movement
and loading requirements and secured to base members by utilizing
manufacturer’s pre-engineered self-centering arrangement that freely
rotates / moves in all directions. The Self centering arrangement shall exhibit
circular sphere ends that lock and slide inside the corresponding aluminum
extrusion cavity to allow freedom of movement and flexure in all directions
including vertical displacement. The Joint System shall resists damage or
deterioration from the impact of falling ice, exposure to UV, airborne
contaminants and occasional foot traffic from maintenance personnel.
Provision of Moisture Barrier Membrane in the Joint System to have water
tight joint is mandatory requirement. Material shall confirm to ASTM 6063.

93
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
23.06 NS AR Providing and Fixing of sky lights consisting of Multi cell/tight cell sqm 320.00 3,546.00 1,134,720
Polycarbonate Panel System of approved colour, 16mm thick (minimum)
having uniform in color with an integral Tight-Cell core constructed not to
exceed 4mm x 4mm in a cross section, Vertical Standing Seam
manufactured at both sides of the panel. Snap-on connector to interlock
the panels shall have a grip-lock double tooth locking mechanism to ensure
maximum uplift capability & shall be of same color as that of panel. Panel
shall be factory sealed/end welded panels with additional End-
cap/Aluminium U-Profile (mill finish) for ends. Panel shall be co-extruded with
special anti glare compound and UV protected. The full system shall be
fitted on MS purlins perpendicular to direction of sheeting with purlin spacing
as specified by Manufacturer.  The weight of the panel only shall not be less
than 3250 gram per square metre.

The rate includes cost of all the operations, labour & all materials and tests
(as applicable) involved such as bolts nuts and screws etc. and labour for
cutting bending to required profile, necessary scaffolding, hoisting in position
etc. for proper completion of the work etc. complete as per specification
drawings and direction of Engineer in charge . Finished surface area of
roofing fixed over steel tubular structure shall be measured for payment. MS
tabular frame work shall be measured separately for payment )

Total of Subhead-23 2,589,730

94
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY- RESIDENTIAL TYPE 1 &2 ( BLOCKS R3)

SUB HEAD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

1 CIVIL WORKS

SH-1 EARTH WORK 560,962

SH-2 PILING WORKS 28,544,231

SH-3 ANTITERMITE TREATMENT 113,139

SH-4 PLAIN CEMENT CONCRETE WORK 347,433

SH-5 REINFORCED CEMENT CONCRETE WORK 21,916,299

SH-6 FORM WORK 10,170,348

SH-7 STEEL REINFORCEMENT WORK 44,926,598

SH-8 BRICK WORK 12,729,677

SH-9 WATER-PROOFING OF RAFT, RETAINING WALL, DECK SLAB, ROOFS, INTERNAL 2,606,476
WET AREAS

SH-10 INSULATION - OVERHEAD & UNDERDECK 819,211

SH-11 PLASTERING - INTERNAL AND EXTERNAL 12,183,651

SH-12 STEEL WORKS 4,287,777

SH-13 WOOD WORK - DOORS, PARTITIONS & PANELING 3,876,412

SH-14 FLOORING, SKIRTING & DADO WORK 13,626,709

SH-15 WALL FINISHES - INTERNAL & EXTERNAL 5,235,935

SH-16 ALUMINIUM WORK FOR DOOR, WINDOWS 11,986,393

95
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-17 FIRE DOORS & ACCESSORIES 618,243

SH-18 HARDWARE FOR DOORS 774,280

SH-19 EXTERNAL FAÇADE - GRC SCREENS, ALUMINIUM LOUVERS 7,873,852

SH-20 MISCELLANEOUS ITEMS 553,676

ESTIMATED COST 183,751,301

LESS 5% FOR UPRNN WORKING (9,187,565)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 174,563,736

96
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

BILL OF QUANTITIES - CIVIL AND INTERIOR WORKS- RESIDENTIAL BLOCKS TYPE 1 & 2

S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

1.00 SH-1 EARTH WORK


1.01 UPPWD 251(4.1.1) Excavation in foundations in ordinary soil (loam, clay and sand) including lift cum 4,072.69 92.00 374,687
SOR 2014 upto 1.5m. (5fts.) and lead upto 30m. (100fts) and including filling, watering
and ramming of excavated earth in to the trenches and into the space b/w
the building and sides of foundation trenches or in to the plinth and removal
and disposal of surplus earth as directed by the engineer-in-charges up to a
distance of 30m. (100 fts) from the foundation trenches.

1.02 UPPWD 254(4.3) Add to item 251 for every additional 30m. (100 fts.) lead or part of 30m. (100 Cum. 200.00 13.00 2,600
SOR 2014 fts) or for every additional 1.5m. (5fts) lift or part of 1.5m (5 fts).

1.03 CPWD 2.25 Filling available excavated earth (excluding rock) in trenches, sides of cum 1,221.81 112.40 137,331
DSR 2014 foundations , plinth, etc. in layers not exceeding 20 cm. in depth,
consolidating each deposited layer by ramming and watering i/c lead upto
50 M and lift upto 1.5M. (Measurement after complete consolidation will be
considered for payment).

1.04 UPPWD 255+deriv Supplying and filling in plinth with local fine sand from river under floors cum 63.80 726.38 46,343
SOR 2014 ed including watering, ramming, consolidating and dressing complete

Total of Subhead-1 - 560,962

97
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

2.00 SH-2 PILING WORKS

2.01 CPWD 20.2A.2 Boring, providing and installing 750 mm dia piles bored cast-in-situ reinforced metre 5,397.00 5,215.40 28,147,514
DSR 2014 cement concrete piles of grade M-25 of specified diameter and length
below the pile cap, to carry a safe working load not less than specified
excluding the cost of steel reinforcement but including the cost of
appropriate length for setting out and removal of same and the length of
the pile to be embedded in the pile cap etc. by crawler mounted,
telescopic boom hydraulic piling rig all complete , including removal of
excavated earth with all lifts and leads (Length of pile for payment shall be
measured upto bottom of pile cap). Tuck mounted rotary / TMR / tube well
boring machine shall not be used.
2.02 CPWD 20.6.2.1 Carrying out Initial Vertical load testing on single pile above 50 tonne to 100 Per test 2.00 46,808.45 93,617
DSR 2014 tonne in accordance with IS 2911 (Part IV) including installation of loading
platform by Kentledge method and preparation of pile head or construction
of test cap and dismantling of test cap after tests etc. complete as per
specifications and the direction of engineer in charge. ( test load 2.5 times
the safe capacity)

2.03 CPWD 20.6.2.2 Carrying out routine Vertical load testing on single pile above 50 tonne to per test 4.00 26,714.50 106,858
DSR 2014 100 tonne in accordance with IS 2911 (Part IV) including installation of
loading platform by kentledge method and preparation of pile head or
construction of test cap and dismantling of test cap after test etc. complete
as per specifications and the direction of engineer in charge. ( Test load 1.5
times the safe capacity)
2.04 CPWD 20.9 Integrity testing of pile using Low Strain/Sonic Integrity Test/Sonic Echo Test Per test 65.00 745.50 48,458
DSR 2014 method in accordance with IS 14893 including surface preparation of pile
top by removing mud, dust & chipping lean concrete lumps etc. and use of
computerized equipment and high skill trained personal for conducting the
test & submission of results, all complete as per direction of engineer-in-
charge.
2.05 CPWD derived Dismantling / Breaking top portion of concrete piles up to pile cut off level cum 113.48 1,302.30 147,785
DSR 2014 from 15.3 and removing rubbish/spoil up to a lead of 50m with all lifts, cleaning top
portion of pile cleaning reinforcement exposed due to breaking of pile top,
bending pile reinforcement into pile cap as per drawing and instruction of
engineer.
Total of Subhead-2 28,544,231

98
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

3.00 SH 3 ANTITERMITE TREATMENT -


3.01 CPWD 2.34.1 Supplying chemical emulsion in sealed containers including delivery as litre 152.00 168.83 25,662
DSR 2014 specified - chloryphos / Lindane emulsifiable concentrate of 20%

3.02 CPWD derived Diluting and injection chemical emulsion (to be supplied free of cost at site Sqm 758.69 115.30 87,477
DSR 2014 '2.35.1+ of work) for pre-constructional. Anti termite treatment and creating a
2.35.2+ continuous chemical barrier as per IS : 6313 part II 1981 under and all-round
2.35.3 the column pits, wall trenches, basement excavation, top surface of plinth
filling, junction of wall and floor along the external perimeter of building,
expansion joints, over the top surface of consolidated earth on which apron
is to be laid, surrounding of pipes and conduits etc., complete as
specifications (plinth area of the building at ground floor only shall be
measured for payment) Chlorpyriphos Emulsifiable concentrate 20% with 1%
concentration.

Total of Subhead-3 - 113,139

4.00 SH-4 PLAIN CEMENT CONCRETE WORK -


4.01 CPWD 4.20 Providing and laying in position ready mix plain cement concrete, with -
DSR 2014 cement content as per approved design mix and manufacture in fully
automatic batching plant and transported to site of work in transit mixer for
all leads, having continuous agitated mixer, manufactured as per mix design
of specific grade for plain cement concrete work, including pumping of RMC
from transit mixer to site of laying i/c curing excluding cost of centering and
shuttering and finishing i/c cost of curing, admixtures in recommended
portion as per IS 9103 to accelerate / retard setting of concrete , improve
workability without impairing strength and durability as per the directions of
engineer in charge.

Note : (1) Excess or less cement used in this item is payable / recoverable -
separately.
4.1.1 CPWD 4.20.1 All works upto plinth level -
DSR 2014
4.1.1.1 CPWD 4.20.1.2 M10 grade plain cement concrete ( cement content considered @ 220 kg cum 69.98 4,964.75 347,433
DSR 2014 per cum)

Total of Subhead-4 - 347,433

99
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
5.00 SH-5 REINFORCED CEMENT CONCRETE WORK -
RMC - -
5.01 CPWD 5.40 Providing and laying in position ready mix M25 grade concrete for reinforced - -
DSR 2014 cement concrete work, using fly ash and cement content as per approved
design mix and manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having continuous
agitated mixer, manufactured as per mix design of specific grade for plain
cement concrete work, including pumping of RMC from transit mixer to site
of laying i/c curing excluding cost of centering and shuttering and finishing
i/c cost of curing, admixtures in recommended portion as per IS9103 to
accelerate / retard setting of concrete , improve workability without
impairing strength and durability as per the directions of engineer in charge.
cement content considered in this item is @ 330 kg per cum of concrete.
Note : (1) Excess or less cement used as per design mix is payable /
recoverable separately. 2. Fly ash confirming to grade I of IS 3812 ( Part 1)
only be used as part replacement of OPC as per IS 456. Uniform blending
with cement is to ensured in accordance with clause 5.2 and 5.2.1 of IS 456-
2000 in the items of B.M.C and R.M.C.
5.1.1 CPWD 5.40.1 All works upto plinth level cum 241.94 6,561.20 1,587,417
DSR 2014
5.1.2 CPWD 5.40.2 All works above plinth level and upto floor V level cum 2,613.02 7,279.60 19,021,740
DSR 2014
5.02 CPWD 5.34.1 Extra for providing richer mixes at all floor levels for providing M-30 grade cum 269.39 76.50 20,608
DSR 2014 concrete in place of M-25 grade B.M.C./R.M.C. ( cement content
considered in M30 @ 340kg. per cum of concrete)

5.03 CPWD 5.34.2 Extra for providing richer mixes at all floor levels for providing M-35 grade cum 2,744.33 152.95 419,745
DSR 2014 concrete in place of M-25 grade B.M.C./R.M.C. ( cement content
considered in M35 @ 350kg. per cum of concrete)

5.04 CPWD 5.38 Extra for R.C.C. / B.M.C. / R.M.C. work above floor V level for each four floors cum 1,983.19 174.20 345,472
DSR 2014 or part there of.

5.05 CPWD 5.13 Providing, hoisting and fixing upto floor five level pre cast reinforced cum 54.60 8,797.80 480,360
DSR 2014 concrete work in small lintels not exceeding 1.5 M clear span including cost
of required centering & shuttering but excluding the cost of
reinforcement1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 20mm
nominal size)

100
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
5.06 CPWD 5.15 Providing, hoisting and fixing upto floor five level pre cast reinforced cum 5.00 8,191.40 40,957
DSR 2014 concrete in lintels, beams and bressumers including setting in cement mortar
1:3 ( 1 cement : 3 coarse sand ) cost of required centering , shuttering
complete but excluding the cost of reinforcement with 1:2:4 ( 1 cement : 2
coarse sand : 4 stone aggregate 20mm nominal size) .

Total of Subhead-5 - 21,916,299


6.00 SH-6 FORM WORK -
6.01 CPWD 5.9.1 Centering and shuttering for foundations, footings, bases of columns etc. for sqm 143.64 196.45 28,218
DSR 2014 mass concrete including strutting, propping, oiling, etc. removal of form work.

6.02 CPWD 5.9.3 Centering and shuttering for suspended floors, roofs, landings, balconies and sqm 7,423.39 401.65 2,981,605
DSR 2014 access platform including strutting, propping, oiling, etc. removal of form
work.
6.03 CPWD 5.9.4 Centering and shuttering for shelves ( cast in situ) including strutting, sqm 269.10 401.65 108,084
DSR 2014 propping, oiling, etc. removal of form work.

6.04 CPWD 5.9.5 Centering and shuttering for lintels, beams, plinth beams, girders, bressumers sqm 4,948.93 332.15 1,643,787
DSR 2014 and cantilevers including strutting, propping, oiling, etc. removal of form
work.
6.05 CPWD 5.9.6 Centering and shuttering for columns, pillars, piers, abutments, posts and sqm 10,801.69 453.35 4,896,946
DSR 2014 struts including strutting, propping, oiling, etc. removal of form work.

6.06 CPWD 5.9.7 Centering and shuttering for stairs (excluding landing) except spiral staircases sqm 989.79 395.65 391,610
DSR 2014 including strutting, propping, oiling, etc. removal of form work.

6.07 CPWD 5.9.16.1 Centering and shuttering for edges of slabs and breaks in floors and walls Metre 160.00 116.40 18,624
DSR 2014 upto 20cm width including strutting, propping, oiling, etc. removal of form
work.
6.08 CPWD 5.11.1 Extra for additional height in centering, shuttering wherever required for sqm 638.00 159.05 101,474
DSR 2014 suspended floors, roofs, landings, beams and balconies ( plan area to be
measured ) with adequate bracing, propping etc. including cost of de-
shuttering and de-centering at all levels, over a height of 3.5m, for additional
height of 1 Metre or part thereof ( plan area to be measured )

Total of Subhead-6 - 10,170,348

101
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

7.00 SH-7 STEEL REINFORCEMENT WORK -

7.01 UPPWD Derived Providing and fixing Thermo-mechanically treated MS bars reinforcement for kg 192,370.00 68.90 13,254,293
SOR 2014 from 504 R.C.C. work including straightening, cutting, bending, placing in position and
binding complete upto plinth level. - Fe 500

7.02 UPPWD Derived Providing and fixing Thermo-mechanically treated MS bars reinforcement for kg 449,510.00 68.90 30,971,239
SOR 2014 from 504 R.C.C. work including straightening, cutting, bending, placing in position and
binding complete above plinth level. - - Fe 500

7.03 5.42 Providing and fixing tapered / parallel threaded couplers conforming to IS -
code on “Reinforcement Couplers for Mechanical Splices of Bars for
Concrete Reinforcement - Specification”, to reinforcement bars including
threading, enlargement at connection by forging, protecting the prepared
reinforcement bars and related operations as required to complete the
works per direction of Engineer-in-Charge. (The length of the bars in which
coupler is to be provided should not be less than 4 metre, no deduction for
labour and binding wire saved for not providing lap length shall be made).

7.3.1 CPWD 5.42.1 Coupler for 16 mm diameter reinforcement bar each 5,730.00 122.35 701,066
DSR 2014

Total of Subhead-7 - 44,926,598

8.00 SH-8 BRICK WORK -

8.01 UPPWD 303 First class brick work in 1:6 cement and fine sand of 1.25 fineness modulus cum 20.00 4,850.00 97,000
SOR 2014 mortar in foundation and plinth including supply of all materials, labour and
tools and plants etc. required for proper completion of the work.

8.02 UPPWD 310 As in item (303) above but in super structure above including necessary cum 1,758.75 5,050.00 8,881,688
SOR 2014 cutting and moulding of brick work as required and also including honey
combed brick in thickness of wall of one brick thick add for extra labour.

102
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
First floor -

8.2.1 UPPWD note Increase in As in item (303) above but in super structure above including cum 106.42 50.50 5,374
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Second floor -

8.2.2 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 101.00 11,052
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Third floor -

8.2.3 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 151.50 16,579
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fourth floor -

8.2.4 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 202.00 22,105
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fifth floor -

8.2.5 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 252.50 27,631
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Sixth floor -

8.2.6 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 303.00 33,157
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

103
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Seventh floor -

8.2.7 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 353.50 38,684
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Eighth floor -

8.2.8 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 404.00 44,210
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Ninth floor -

8.2.9 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 454.50 49,736
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Tenth floor -

8.2.10 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 505.00 55,262
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Eleventh floor -

8.2.11 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 555.50 60,788
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Twelveth floor -

8.2.12 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 606.00 66,315
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

104
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Thirteenth floor -

8.2.13 UPPWD note Increase in As in item (303) above but in super structure above including cum 109.43 656.50 71,841
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fourteenth floor -

8.2.14 UPPWD note Increase in As in item (303) above but in super structure above including cum 140.58 707.00 99,390
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fifteenth floor -

8.2.15 UPPWD note Increase in As in item (303) above but in super structure above including cum 97.62 757.50 73,947
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Sixteenth floor -

8.2.16 UPPWD note Increase in As in item (303) above but in super structure above including cum 44.75 808.00 36,158
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Seventeenth floor -

8.03 UPPWD 310(a) As in item (303) above but in super structure above including necessary cum 493.90 5,150.00 2,543,585
SOR 2014 cutting and moulding of brick work as required and also including honey
combed brick in thickness of wall of half brick (4.1/2")thick. Add for extra
labour over item no. 310 of one brick thick add for extra labour.

105
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
First floor -

8.3.1 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 51.50 1,815
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Second floor -

8.3.2 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 103.00 3,630
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Third floor -

8.3.3 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 154.50 5,445
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fourth floor -

8.3.4 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 206.00 7,259
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fifth floor -

8.3.5 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 257.50 9,074
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Sixth floor -

106
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.3.6 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 309.00 10,889
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Seventh floor -

8.3.7 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 360.50 12,704
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Eighth floor -

8.3.8 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 412.00 14,519
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Ninth floor -

8.3.9 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 463.50 16,334
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Tenth floor -

8.3.10 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 515.00 18,149
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Eleventh floor -

8.3.11 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 566.50 19,963
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

107
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Twelveth floor -

8.3.12 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 618.00 21,778
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Thirteenth floor -

8.3.13 UPPWD note Increase in As in item (303) above but in super structure above including cum 35.24 669.50 23,593
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fourteenth floor -

8.3.14 UPPWD note Increase in As in item (303) above but in super structure above including cum 43.74 721.00 31,537
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

8.04 CPWD 6.15 Extra for providing and placing in position 2 nos. 6mm dia M.S. bars at every sqm 4,294.77 69.50 298,487
DSR 2014 third course of half brick masonry with FPS bricks in superstructure above
plinth level up to floor V level

Total of Subhead-8 - 12,729,677

108
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.00 SH-9 WATER-PROOFING OF RAFT, RETAINING WALL, DECK SLAB, ROOFS,
INTERNAL WET AREAS

SUNKEN AREA WATERPROOFING - -

9.01 CPWD 22.5 Providing and laying water proofing treatment in sunken portion of WCs, sqm 1,807.74 283.10 511,771
DSR 2014 bathroom etc., by applying cement slurry mixed with water proofing cement
compound consisting of applying : (a) Ist layer of slurry of cement @ 0.488
kg/sqm mixed with water proofing compound @0.253 kg/per sqm. This layer
will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @
0.242 kg/sqm mixed with water proofing compound @0.126 kg/sqm. This
layer will be allowed to air cure for 4 hours followed with water curing for 48
hours. The rate includes preparation of surface, treatment and sealing of all
joints, corners, junction of pipes and masonry with polymer mixed slurry.

9.02 CPWD 13.6.1 20 mm cement plaster of mix Cement mortar 1:4. to protect the sqm 1,807.74 242.05 437,563
DSR 2014 waterproofing

ROOF WATERPROOFING -

9.03 CPWD 22.7.1 Providing and laying integral cement based water proofing treatment sqm 812.07 1,019.05 827,540
DSR 2014 including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations: a) Applying a slurry
coat of neat cement using 2.75 kg/sqm of cement admixed with water
proofing compound conforming to IS. 2645 and approved by Engineer-in-
charge over the RCC slab including adjoining walls upto 300 mm height
including cleaning the surface before treatment. b) Laying brick bats with
mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of
cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge
over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand
) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and treating similarly the
adjoining walls upto 300 mm height including rounding of junctions of walls
and slabs

109
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the
surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing compound conforming to IS :
2645 and approved by Engineer-in-charge including laying glass fibre cloth
of approved quality in top layer of plaster and finally finishing the surface
with trowel with neat cement slurry and making pattern of 300x300mm
square 3 mm deep. e) The whole terrace so finished shall be flooded with
water for a minimum period of two weeks for curing and for final test. All
above operations to be done in order and as directed and specified by the
Engineer-in-Charge :..With average thickness of 120 mm and minimum
thickness at khurra as 65 mm.

9.04 NS AR-14 Providing and fixing aluminum flashing , wherever required for termination of Metre 367.38 495.00 181,853
Bituthene membrane at all locations . Item shall include rates for membrane
termination on the Vertical parapet wall at height as specified in drawings
for termination of the membrane.

9.05 NS AR-15 Providing and applying sealing penetration of PVC sleeves of 150mm all- each 12.00 1,744.80 20,938
round on the "Preprufe" membrane with a 2 component liquid membrane /
Bituthene LM, 25mm x 20mm size ADCOR 500S wrapped around pipe of any
dia as per drawing after fixing of double sides Preprufe tape HC complete .

Protection on Terrace Waterproofing -

9.06 CPWD 4.20.2.1 Providing and laying in position ready mix plain cement concrete M15 cum 60.91 6,540.90 398,406
DSR 2014 GRADE , with cement content as per approved design mix and manufacture
in fully automatic batching plant and transported to site of work in transit
mixer for all leads, having continuous agitated mixer, manufactured as per
mix design of specific grade for plain cement concrete work, including
pumping of RMC from transit mixer to site of laying i/c curing excluding cost
of centering and shuttering and finishing i/c cost of curing, admixtures in
recommended portion as per IS 9103 to accelerate / retard setting of
concrete , improve workability without impairing strength and durability as
per the directions of engineer in charge. MINIMUM CEMENT 240 all work
above plinth level upto level 5.

110
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.07 CPWD 22.14.1 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cum 40.60 5,570.55 226,164
DSR 2014 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size )

9.08 CPWD 12.22 Making khurras 45x45cm with average minimum thickness of 5cm cement each 12.00 186.65 2,240
DSR 2014 concrete 1:2:4 over PVC sheet 1mx1m x 400, micron finished with 12mm
cement plaster 1:3 and one coat of neat cement rounding of edges and
making and finishing the outlet complete.

Total of Subhead-9 - 2,606,476

10.00 SH10 INSULATION - OVERHEAD & UNDERDECK

10.01 CPWD 12.56 Providing and laying roof insulation with 40 mm thick impervious sprayed, sqm 701.86 1,167.20 819,211
DSR 2014 closed cell free Rigid Polyurethane foam over deck insulation conforming to
IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of
polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene
sheet over PUF spray and providing a wearing course of 40 mm thick cement
screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal
size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding
with 24 G wire netting and sealing the joints with polymerized mastic, all
complete as per direction of Engineer-in-Charge

Total of Subhead-10 - 819,211

11.00 SH-11 PLASTERING - INTERNAL AND EXTERNAL -


Wall plaster - -
11.01 UPPWD 586 12 mm thick plaster with cement mortar in proportion of 1:6 cement & fine sqm 9,590.55 109.00 1,045,370
SOR 2014 sand of 1.25 F.M.

11.02 CPWD 13.5.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:6 sqm 14,385.82 183.45 2,639,079
DSR 2014 ( 1 cement:6 coarse sand )

111
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
11.03 CPWD 13.5.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 sqm 4,330.20 183.45 794,375
DSR 2014 ( 1 cement:4 coarse sand ) in internal walls of service shafts

11.04 UPPWD 584+587 12mm cement plaster to ceiling of cement mortar mix 1:4 (1 cement : 4 fine sqm 8,243.41 137.00 1,129,347
SOR 2014 sand of 1.25 FM).

11.05 CPWD 5.30 Add or deduct for plaster drip course / groove in plastered surface or Metre 750.00 30.75 23,063
DSR 2014 moulding to RCC projections.

11.06 CPWD 13.11 18mm cement plaster in two coats under layer 12 mm thick cement plaster sqm 10,990.07 240.55 2,643,661
DSR 2015 1:5 ( 1cement:5 coarse sand ) finished with a top layer 6 mm thick cement
plaster 1:6 ( 1cement : 6 fine sand ).

11.07 CPWD 13.22 Extra for plastering exterior walls of height more than 10 m from ground level sqm 8,733.16 37.95 331,423
DSR 2014 for every additional height of 3 m or part thereof.

11.08 CPWD 4.18 Extra for addition of synthetic Polyester triangular fibre of length 12mm, per bag 2,198.01 53.00 116,495
DSR 2014 effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in of 50kg
cement concrete/RCC/Flooring/water retaining structures by using 125gms of cement
synthetic Polyester triangular fibre for 50 Kg cement used as per directions of
Engineer-in-Charge.

11.09 CPWD 7.23.2.5 30mm thick white sand stone work (machine cut edges) -exposed face Sqm. 1,100.00 3,036.60 3,340,260
DSR 2014 machine cut and table rubbed with rough backing for wall lining etc.
(veneer work) backing filled with a grout of 12 mm thick cement mortar 1:3
(1 cement :3 coarse sand) including pointing in with white cement mortar 1:2
( 1 white cement : 2 stone dust) with an admixture of pigment matching the
stone shade. ( To be secured to the backing by means of cramps shall be
paid for separately )

11.10 CPWD 7.32.2 White sand stone work, plain in copings, cornices, string course and plinth cum 3.09 39,022.00 120,578
DSR 2014 courses in cement mortar 1:6 ( 1 cement : 6 coarse sand) including pointing
with white cement pointing with white cement mortar 1:2 ( 1 white cement:2
stone dust) with an admixture of pigment matching the stone shade.

Total of Subhead-11 - 12,183,651

112
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

12.00 SH-12 STEEL & STRUCTURAL STEEL WORKS -

12.01 CPWD 10.2 Structural steel work riveted, bolted or welded in built up sections, in pergola, Kg 9,117.54 73.95 674,242
DSR 2014 railing, trusses and frame work, including cutting, hoisting, fixing in position
and applying a priming coat of approved steel primer etc. all complete as
directed by Engineer-in-charge at all heights and depths.

12.02 CPWD 7.41 Providing and fixing structural steel frame ( for dry cladding with 30mm thick Kg 15,200.00 143.55 2,181,960
DSR 2014 gang saw cut with machine cut edges sand stone ) on walls at all heights
using M.S. square / rectangular tube in the required pattern as per
architectural drawing including cost of cutting, bending, welding etc. The
frame work shall be supported in wall with the help of MS brackets / lugs of
angle iron / flats etc. which shall be welded to the frame and embedded in
brick wall with cement concrete block 1:2:4 ( 1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) of size 300x230x300mm
including necessary cost of centering and shuttering and with approved
expansion hold fasteners on CC / RCC surface including drilling necessary
holes. Approved cramps / pins etc. shall be welded to the frame work to
support stone cladding the steel work will be given a priming coat of Zinc
primer as approved by Engineer-in-charge and painted with two or more
coats of epoxy paint ( shop drawings shall be submitted by the contractor to
the Engineer-in-charge for approval before execution). The frame work shall
be fixed in true horizontal & vertical lines / planes. ( Only structural steel
frame work shall be measured for the purpose of payment, stainless steel
cramps shall be paid for separately and nothing extra shall be paid ).

12.03 CPWD 10.25 Steel work welded in built up sections/ framed work including cutting, - -
DSR 2014 hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.

12.3.1 CPWD 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar kg 13,809.00 90.10 1,244,191
DSR 2014 works.

12.04 NS AR P/F Hollock wood hand rail for staircase size 65mm x 120mm fixed to mild Metre 218.60 857.20 187,384
steel flat with screws i/c spirit polishing after applying wood filler.

Total of Subhead-12 - 4,287,777

113
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

14.00 SH-14 WOOD WORK - DOORS, PARTITIONS & PANELING

14.02 CPWD 9.1.3 Providing Kiln seasoned and chemically treated Hollock wood work in cum 20.27 53,698.60 1,088,471
DSR 2014 frames of doors, windows, clerestory windows and other frames, wrought
framed and fixed in position with hold fast lugs or dash fastener of required
dia and length ( hold fast lugs or dash fastener shall be paid for separately).

14.06 CPWD 9.20.1 Providing and fixing 35mm thick ISI marked flush door shutter confirming to IS sqm 544.00 2,606.45 1,417,909
DSR 2014 : 2202 ( part I) decorative type, core of block board construction with frames
of first class hard wood and well matched teak 3 ply veneering with vertical
grains or cross bands and face veneers on both sides of shutters fixed with ISI
marked stainless steel butt hinges with necessary hinges.

14.07 CPWD 9.21.2 Providing and fixing 30mm thick ISI marked flush door shutters conforming to sqm 247.00 1,735.35 428,631
DSR 2014 IS :2202 (Part I) non-decorative type, core of block board construction with
frame of 1st class hard wood and well matched commercial 3 ply veneering
with vertical grains or cross bands and face veneers on both faces of
shutters, including ISI marked Stainless Steel butt hinges with necessary
screws

14.08 CPWD 9.23 Extra for providing lipping with second class teak wood battens 25mm sqm 791.00 365.85 289,387
DSR 2014 minimum depth on all edges of shutters ( over all area of door shutter to be
measured ).

14.10 CPWD 9.40.2.2 Providing and fixing 50x20 mm Hollock wood moulded beading to door and metre 2,357.20 117.95 278,032
DSR 2014 window frame with iron screws plugs and priming coat on unexposed
surface etc. complete.

14.11 CPWD 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with each 1,776.00 117.35 208,414
DSR 2014 10 mm diameter bolts, nuts and wooden plugs and embedding in cement
concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded
stone aggregate 20mm nominal size)

14.13 CPWD 17.31 Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of each 168.00 793.95 133,384
DSR 2014 approved quality) complete with 6 mm thick hard board ground fixed to
wooden cleats with C.P. brass screws and washers complete.

114
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
14.14 CPWD 14.28.2 Providing and fixing 25mm diameter curtain rod of 1.25 mm thick brass plates metre 100.00 235.10 23,510
DSR 2014 with two brass brackets fixed with brass screws and wooden plugs etc.
wherever necessary complete

14.15 CPWD 10.27.3 Providing and fixing 10 x 120 mm carbon steel galvanised ( minimum coating each 100.00 86.75 8,675
DSR 2014 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield
strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide
PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry,
etc. as per direction of Engineer-in-charge.
Total of Subhead-14 3,876,412
15.00 SH-15 FLOORING, SKIRTING & DADO WORK

15.02 CPWD 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and sqm 2,076.57 1,141.40 2,370,197
DSR 2014 jointed with grey cement slurry mixed with pigment to match the shade of
the slab, including rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) : 25mm thick

15.03 CPWD 11.39 Providing and laying rectified ceramic glazed floor tiles 300x300mm or more sqm 5,141.50 950.05 4,884,682
DSR 2014 (thickness to be specified by the manufacturer) of Ist quality confirming to IS :
15622 of approved make in all colours except as white, Ivory , grey , fume
red brown laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand)
including pointing the joints with white cement and matching pigments etc.
complete

15.06 CPWD 11.37 Providing and laying ceramic glazed floor tiles 300x300mm in size ( thickness sqm 952.76 785.40 748,298
DSR 2014 to be specified by the manufacturer) of Ist quality confirming to IS : 15622 of
approved make in colours such as white, Ivory , grey , fume red brown laid
on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) including
pointing the joints with white cement and matching pigments etc. complete

15.11 CPWD 11.27 Providing and laying 25mm thick Kota stone slabs in skirting, dado, pillars, sqm 1,592.72 1,191.25 1,897,328
DSR 2014 risers of steps (area upto 900 sqcm) laid on 12mm thick (Avr) cement mortar
1:3 ( 1 cement : 3 coarse sand) and jointed with grey cement slurry mixed
with pigment to match the shade of stone slabs, including necessary cutting,
rubbing and polishing etc. complete.

115
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.12 CPWD 11.36 Providing and fixing Ist quality ceramic glazed wall tiles conforming to sqm 3,314.79 836.65 2,773,319
DSR 2014 IS:15622 (thickness to be specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white
cement mixed with pigment of matching shade complete

15.13 CPWD 8.2.1.2 Providing and laying 18mm thick mirror polished, machine cut marble for sqm 308.75 2,463.55 760,621
DSR 2014 kitchen platforms, vanity counters, facias, window sills and similar locations of
required size of approved shade, colour and texture laid over 20mm thick
base cement mortar 1:4 ( 1 cement : 4 coarse sand) with joints treated with
white cement mixed with matching pigment, epoxy touch ups including
rubbing, curing etc. complete at all levels. Raj Nagar plain white marble/
Udaipur green marble/ Zebra black marble -Area of slab over 0.5 sqm

15.14 CPWD 8.3.1 Providing edge moulding to 18mm thick marble stone counters, vanities etc. metre 396.50 136.10 53,964
DSR 2014 including machine polishing to edge to give high gloss finish etc. complete
as per design approved by engineer in charge.

15.16 CPWD 8.4 Extra for fixing marble / granite stone over and above corresponding item in metre 396.50 247.40 98,094
DSR 2014 facia and drops of width upto 150mm with epoxy resin based ( Araldite or
equivalent) adhesive including cleaning etc. complete

15.17 CPWD 8.5 Extra for providing opening of required size & shape for wash basins / each 104.00 386.60 40,206
DSR 2014 kitchens sink in kitchen platform, vanity counters and similar location in opening
marble / stone work including necessary holes for pillar taps etc. including
rubbing and polishing of cut edges etc. complete.

Total of Subhead-15 13,626,709

116
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
17.00 SH-17 WALL FINISHES - INTERNAL & EXTERNAL

17.01 CPWD 13.26 Providing and applying plaster of Paris putty of 2mm thickness over plastered sqm 20,139.92 110.95 2,234,524
DSR 2014 surface to prepare the surface even and smooth complete.

17.02 NS AR Making groove in plaster of paris putty on walls and skirting metre 2,100.00 32.80 68,880

17.03 CPWD 13.37.1 White washing with lime to give an even shade, New work ( three or more sqm 4,330.20 16.20 70,149
DSR 2014 coats ).

17.04 CPWD 13.45.1 Finishing walls with textured exterior paint of required shade: New work ( two Sqm. 8,242.55 146.45 1,207,121
DSR 2014 or more coats applied @ 3.28 litre/10 sqm) over and including base coat of
water proofing cement paint applied @ 2.20kg/10sqm.

17.06 CPWD 13.81.2 Distempering two with 1st quality acrylic distemper, having VOC (Volatile sqm 28,383.34 45.70 1,297,119
DSR 2014 Organic Compound ) content less than 50 grams/ litre, of approved brand
and manufacture, including applying additional coats wherever required, to
achieve even shade and colour.

17.08 CPWD 13.84.2 Painting with two coats synthetic enamel paint, having VOC (Volatile sqm 1,868.81 71.60 133,807
DSR 2014 Organic Compound) content less than 150 grams/ litre, of approved brand
and manufacture, including applying additional coats wherever required to
achieve even shade and colour.

17.09 NS AR Providing and applying of 2 coats of exterior Metallic paint of approved sqm 635.90 270.00 171,693
shade in silver finish i/c applying wall care putty, exterior wall primer on walls
as per specifications complete.

17.10 CPWD 13.85.1 Applying priming coats with ready mixed pink or grey primer on wood work sqm 1,458.22 36.10 52,642
DSR 2014 (hard and soft wood) having VOC content less than 50 grams/ litre of
approved brand and manufacture.

Total of Subhead-17 5,235,935

117
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

18.00 SH-18 ALUMINIUM WORK - DOOR, WINDOWS


18.01 CPWD 21.1 Providing, fixing, supplying, installation and design of aluminium work for -
DSR 2014 doors, windows, ventilators and partitions with extruded built up standard
tubular sections/appropriate Z sections and other sections of approved
make confirming to IS: 733 and IS: 1285 fixed with rawl plugs and screws or
with fixing clips or with expansion hold fasteners including necessary filling up
of gaps at junctions, at top , bottom and sides with required PVC / neoprene
felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including cleat angle, aluminium
snap beading for glazing / paneling, CP brass / SS screws all complete as per
architectural drawings and the direction of Engineer-in-charge.(Glazing and
paneling to be paid for separately):

18.1.1 CPWD 21.1.1.1 Fixed Windows -Anodised aluminium (anodised transparent or dyed to kg 146.00 348.50 50,881
DSR 2014 required shade according to IS: 1868, Minimum anodic coating of grade AC
15)

18.1.2 CPWD 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade kg 15,838.00 405.90 6,428,644
DSR 2014 according to IS: 1868, Minimum anodic coating of grade AC 15) -For shutters
of doors, windows & ventilators including providing and fixing hinges/ pivots
and making provision for fixing of fittings wherever required including the
cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for
separately)

18.02 CPWD 21.8.1 Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone metre 4,223.00 88.75 374,791
DSR 2014 work Upto 5mm depth and 5 mm width by providing weather silicon sealant
over backer rod of approved quality as per architectural drawings and
direction of Engineer-in-charge.

18.03 CPWD 21.11.3 Providing and fixing stainless steel ( SS304 grade ) adjustable friction windows each 926.00 350.70 324,748
DSR 2014 stays 355 x 19 mm of approved quality with necessary stainless steel screws
etc. to the side hung windows as per direction of Engineer-in-charge
complete.

118
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
18.08 CPWD 21.3.2 Providing and fixing 6mm clear float glass glazing in aluminium doors, sqm 2,859.45 1,054.20 3,014,432
DSR 2014 window, ventilators, shutters and partition etc. with PVC / neoprene gasket
etc. complete as per architectural drawing and the direction of the Engineer-
in-charge. ( cost of aluminium snap beading shall be paid in basic items.)

18.11 CPWD 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to kg 3,336.00 312.20 1,041,499
DSR 2014 required shade according to IS: 1868, Minimum anodic coating of grade AC
15) sub frame work for windows and ventilators with extruded built up
standard tubular sections of approved make conforming to IS: 733 and IS:
1285 fixed with rawl plugs and stainless steel screws etc.

18.14 CPWD 10.29.1 Providing & fixing fly proof Galvanised M.S. Wire gauze with 0.63 mm dia wire Sqm 1,395.87 538.30 751,397
DSR 2014 and 1.4 mm aperture on both sides to windows, clerestory windows & doors
with M.S. Flat 15x3 mm and nuts & bolts complete.

Total of Subhead-18 11,986,393

19.00 SH-19 FIRE DOORS & ACCESSORIES

19.01 NS AR Supply and fixing of Interlayered FR Glass of Saint-Gobain, Torch, Glaberwel no. 17.00 6,998.00 118,966
make minimum 11 mm thick interlayered , 120 minutes fire Rated (EW120, EI
15 minutes ) Non Wired, Toughened Interlayered Glass of approved make
which can also withstand thermal shock upto 800 degree centigrade shall be
used as a glazing (Vision Panel Top/side fixed glazing) and is to be fixed in
between the glass beading by using ceramic fiber in accordance with BS :
476 Part 22/ EN 1363 EN 1364 for stability and integrity of size 300 mm x 500mm
(Clear vision ) and the manufacturer should have tested the glass of similar or
bigger size with any type of door framing from CBRI Roorkee . The Location of
the Fr Glass will be as per the directions of Engineer-in-charge ( Actual Glass
size will be measured for payment).

119
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.02 NS AR Supply and fixing of Hollock wood - door frame of section 120 mm x 70 mm metre 93.50 1,350.00 126,225
with heat activated intumescent fire seal strip of section 10 mm x 4 mm 2 no.
of Sealz, Fire & Acoustic , Viper make . The frame is duly primer with FR
retardant primer FR880 type primer and FR Paint FRS type. The frame should
be fixed in existing opening with thr help of anchor fastener of appropriate
size as per direction of Engineer in Charge. The manufacturer should be an
ISO certified and IGBC registered member. The approved manufacturer are
Navair , Promat , Godrej , Shakatimet .

19.03 NS AR Providing and fixing of 52mm thick Wooden fire rated door shutters tested as
per BS:476 Part- 20 & 22 & IS 3614 Part-2 for stability, integrity and thermal
insulation. Recommended fire door shall have doors tested at CBRI vide test
report FR No. 0291 for maximum rating of 2hrs tested either with or without
vision panel. Individual Test certificates should be available for glass used in
vision lites confirming the required fire ratings. The shutter should be
maximum 52 mm thick upto commercial ply facing and lamination , if
required should be over and above . The core insulation should be asbestos
free comprising of two 12 mm thick Calcium Silicate boards of Pamtech
type , a 100% without Asbestos, having density not more than 900Kg/M3 and
thermal conductivity 0.14 W/m*K with non-combustibility as per BS 476 part 4-
1970 and class-1 surface spread as per BS-476 Part-7-1971 . These boards
sandwiching 20 mm thick fire resistance insulation filler faced with 03 mm
thick commercial ply facing on both faces .. the shutter is provided with heat
activated intumescent fire seal strip of size 20mm x 4 mm mounted in the
grooves of 2nd class teak wood Exposed lipping on all sides except bottom.
The intumescent fire retardant sealant should be used to fill the gaps
between civil opening and frame along with wool insulation so as to fill any
visible gap . The manufacturer should submit desired design test report for a
design tested earlier for 120 minutes fire rating along with Vision Panel tested
at CBRI Roorkee as per direction's of Engineer in Charge. The manufacturer
should be an ISO certified and IGBC registered member. The approved
manufacturer are Navair , Promat , Godrej , Shakatimet .

19.03 NS AR Door Shutter with Paint Finish FD - 95 no. doors sqm 39.27 5,681.00 223,093

19.04 NS AR Supply & fixing of SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with each 68.00 361.00 24,548
SS Screws of BB1953 Becker F.S / 3090F DORMA / 8011008 GEZE Make ( 4 Nos
per panel ) (Required For All Doors)

120
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.05 NS AR Supply & fixing of SS D Type Pull Handle of size 300mm mm Long of PHD2230 each 34.00 550.00 18,700
Becker F.S/ 8133006 GEZE/ TGDI30022 DORMA Make.

19.06 NS AR Supply & fixing of door closers of BLC-0408 Becker F.S/ TS-73V DORMA / TS2000 each 17.00 4,260.00 72,420
GEZE Make. (Required For All Fire Door)

19.07 NS AR Supply & fixing of anchor fasteners of HILTI/ FISHER/ Equivalent of maximum each 153.00 97.00 14,841
120mm length.

19.08 CPWD 13.58 Providing and applying two coats of fire retardant paint unthinned on sqm 78.54 247.65 19,450
DSR 2014 cleaned wood/ply surface @ 3.5 sqm per litre per coat including
preparation of base surface as per recommendations of manufacturer to
make the surface fire retardant.

Total of Subhead-19 618,243

21.00 SH21 HARDWARE FOR DOORS

21.01 CPWD 9.97.1 Providing and fixing 300x10mm size aluminum tower bolts ISI marked each 128.00 112.10 14,349
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete

21.02 CPWD 9.97.2 Providing and fixing 250x10mm size aluminium tower bolts ISI marked each 232.00 95.25 22,098
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete

21.03 CPWD 9.97.4 Providing and fixing 150x10mm size aluminum tower bolts ISI marked each 760.00 65.35 49,666
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete

121
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
21.04 CPWD 9.97.5 Providing and fixing 100x10mm size aluminium tower bolts ISI marked each 140.00 52.35 7,329
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete
21.05 CPWD 9.101.2 Providing and fixing aluminum hanging twin rubber floor door stopper ISI each 672.00 83.95 56,414
DSR 2014 marked anodised (anodic coating not less then grade AC 10 as per IS :1868
) transparent or dyed to required colour or shade with necessary screw etc.
complete

21.06 CPWD 9.113 Providing & fixing bright finished 100mm mortice lock with 6 levers without each 114.00 465.95 53,118
DSR 2014 pair of handles for aluminum door with necessary screws etc. complete (Best
make of approved quality) as per direction of Engineer-in-charge.

21.07 CPWD 9.96.1 Providing and fixing aluminium sliding door bolt 300x16mm ISI marked each 156.00 229.65 35,825
DSR 2014 anodised (anodic coating not less then grade AC 10 as per IS :1868 )
transparent or dyed to required colour or shade with necessary screw etc.
complete

21.11 CPWD 21.04.1 Providing and fixing double action hydraulic floor spring of approved brand each 8.00 2,039.00 16,312
DSR 2014 and manufacture conforming to IS : 6315, having brand logo embossed on
the body / plate with double spring mechanism and door weight upto 125
kg, for doors, including cost of cutting floors, embedding in floors as required
and making good the same matching to the existing floor finishing and
cover plates with brass pivot and single piece M.S. sheet outer box with slide
plate etc. complete as per the direction of Engineer-in-charge -With stainless
steel cover plate minimum 1.25 mm thickness

21.14 NS AR Providing and fixing Sliding door handle with lock each 292.00 373.00 108,916

21.16 NS AR Providing and fixing Sliding window handle with lock each 584.00 373.00 217,832

21.17 NS AR Providing and fixing casement window handle each 463.00 380.00 175,940

21.18 NS AR Providing and fixing casement Door handle each 16.00 380.00 6,080

21.20 NS AR P/F Magic eye as per approved sample each 104.00 100.00 10,400

Total of Subhead-21 774,280

122
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
22.00 SH22 EXTERNAL FAÇADE - GRC SCREENS,ALUMINIUM LOUVERS

22.01 NS AR Providing and Fixing of (Glass Fibre Reinforced Jali)GRC Jalli 50 mm thick of sqm 1,518.29 5,186.00 7,873,852
size, pattern, design, thickness and colour of approved make to be fixed
on/between RCC / Block work Column or structural steel work in vertical with
Dry Fixing method with all appropriate steel frame work , using appropriate
fasteners, and necessary hardware with scaffolding, etc in Building Façade.
The jali shall be made from 53 grade White Portland Cement . Super
Plasticizers, UV Resistant Synthetic inorganic pigments shall be used for
pigmentation. The jali shall be securely fixed with stainless steel bolts and
anchor fasteners(304 grade) of required size at specified locations. The rate
includes the cost of 50 mm thick Jali, SS brackets, anchor fasteners, SS sleeves
labour charges for fixing, required scaffolding etc. for all heights and leads.
The surface area of Jali shall be measured for payment.

Total of Subhead-22 7,873,852

23.00 SH-23 MISCELLANEOUS ITEMS

23.03 NS AR Supplying, drilling/ cleaning hole and injecting Hilti or equivalent ETA
approved HIT-RE 500 chemical with the help of Hilti HDM 500 dispenser, into a
23.3.1 NS AR hole ofDia,
10mm dia rebar
and depth
150mmasdepth
per manufacture's structural consultant each 965.00 153.98 148,591

23.3.2 NS AR 12mm Dia, rebar 180mm depth each 579.00 308.00 178,332

23.3.3 NS AR 16mm Dia, rebar 240mm depth each 97.00 538.95 52,278

23.3.4 NS AR 20mm Dia, rebar 300mm depth each 48.00 1,047.00 50,256

23.3.5 NS AR 25mm Dia, rebar 375mm depth each 19.00 2,301.77 43,734

123
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
23.04 NS AR Supplying, drilling/ cleaning hole and fixing Hilti or equivalent make heavy -
duty ETA approved Toque controlled expansion HSL -3-B mechanical anchor
of appropriate size in concrete and fixing plates subsequently. The anchor
should be consist of 8.8 grade bolt with safety cap, washers, distance sleeve,
expansion sleeve, cone and a collapsible plastic section. All steel
components should be galvanised to minimum 5 microns. Red cap should
come out after required setting torque is applied for installation.
manufacturer should submit anchor design report based on design loads
and other parameters as provided by consultant. Metal anchors should be
designed in accordance with ETAG 001 annexure C guidelines for
anchorage of metal anchors for use in concrete. Application at site should
be done as per manufacturer guidelines.

23.4.1 NS AR M12 of standard length each 10.00 785.85 7,859

23.4.2 NS AR M16 of standard length each 10.00 1,468.56 14,686

23.4.3 NS AR M20 of standard length each 10.00 2,499.84 24,998

23.4.4 NS AR M24 of standard length each 10.00 3,294.28 32,943

Total of Subhead-23 553,676

124
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY- RESIDENTIAL TYPE ( BLOCKS R1& R2)

SUB HEAD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

1 CIVIL WORKS

SH-1 EARTH WORK 845,685

SH-2 PILING WORKS 26,848,541

SH-3 ANTITERMITE TREATMENT 124,476

SH-4 PLAIN CEMENT CONCRETE WORK 2,011,270

SH-5 REINFORCED CEMENT CONCRETE WORK 53,005,593

SH-6 FORM WORK 18,849,052

SH-7 STEEL REINFORCEMENT WORK 78,641,220

SH-8 BRICK WORK 13,867,354

SH-9 WATER-PROOFING OF RAFT, RETAINING WALL, DECK SLAB, ROOFS, INTERNAL 16,653,656
WET AREAS

SH-10 INSULATION - OVERHEAD & UNDERDECK 826,821

SH-11 PLASTERING - INTERNAL AND EXTERNAL 14,291,147

SH-12 STEEL WORKS 10,427,162

125
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-13 EXTERNAL FAÇADE WORK - ALUMINIUM, GLASS , GLASS DOORS 1,192,759

SH-14 WOOD WORK - DOORS, PARTITIONS & PANELING 4,808,672

SH-15 FLOORING, SKIRTING & DADO WORK 29,705,455

SH-16 FALSE CEILING WORKS 1,164,522

SH-17 WALL FINISHES - INTERNAL & EXTERNAL 6,297,111

SH-18 ALUMINIUM WORK FOR DOOR, WINDOWS 19,030,903

SH-19 FIRE DOORS & ACCESSORIES 2,684,303

SH-20 STAINLESS STEEL & GLASS RAILING WORKS 8,350,732

SH-21 HARDWARE FOR DOORS 1,617,247

SH-22 EXTERNAL FAÇADE - GRC SCREENS, ALUMINIUM LOUVERS 6,451,540

SH-23 MISCELLANEOUS ITEMS 2,547,267

ESTIMATED COST 320,242,487

LESS 5% FOR UPRNN WORKING (16,012,124)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 304,230,363

126
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
BILL OF QUANTITIES - CIVIL AND INTERIOR WORKS- RESIDENTIAL BLOCKS TYPE 3 &4

S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

1.00 SH-1 EARTH WORK


1.01 UPPWD 251(4.1.1) Excavation in foundations in ordinary soil (loam, clay and sand) including lift cum 5,053.62 92.00 464,933
SOR 2014 upto 1.5m. (5fts.) and lead upto 30m. (100fts) and including filling, watering
and ramming of excavated earth in to the trenches and into the space b/w
the building and sides of foundation trenches or in to the plinth and removal
and disposal of surplus earth as directed by the engineer-in-charges up to a
distance of 30m. (100 fts) from the foundation trenches.

1.02 UPPWD 254(4.3) Add to item 251 for every additional 30m. (100 fts.) lead or part of 30m. (100 Cum. 2,802.00 13.00 36,426
SOR 2014 fts) or for every additional 1.5m. (5fts) lift or part of 1.5m (5 fts).

1.03 CPWD 2.25 Filling available excavated earth (excluding rock) in trenches, sides of cum 1,209.00 112.40 135,892
DSR 2014 foundations , plinth, etc. in layers not exceeding 20 cm. in depth,
consolidating each deposited layer by ramming and watering i/c lead upto
50 M and lift upto 1.5M. (Measurement after complete consolidation will be
considered for payment).

1.04 UPPWD 255+ Supplying and filling in plinth with local fine sand from river under floors cum 286.95 726.38 208,435
SOR 2014 derived including watering, ramming, consolidating and dressing complete

Total of Subhead-1 - 845,685

127
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

2.00 SH-2 PILING WORKS

2.01 CPWD 20.2A.2 Boring, providing and installing 750 mm dia piles bored cast-in-situ reinforced metre 3,318.00 5,215.40 17,304,697
DSR 2014 cement concrete piles of grade M-25 of specified diameter and length
below the pile cap, to carry a safe working load not less than specified
excluding the cost of steel reinforcement but including the cost of
appropriate length for setting out and removal of same and the length of
the pile to be embedded in the pile cap etc. by crawler mounted,
telescopic boom hydraulic piling rig all complete , including removal of
excavated earth with all lifts and leads (Length of pile for payment shall be
measured upto bottom of pile cap). Tuck mounted rotary / TMR / tube well
boring machine shall not be used.
2.02 CPWD 20.2.3 Boring, providing and installing 450 mm dia piles bored cast-in-situ reinforced metre 4,544.00 1,665.35 7,567,350
DSR 2014 cement concrete piles of grade M-25 of specified diameter and length
below the pile cap, to carry a safe working load not less than specified
excluding the cost of steel reinforcement but including the cost of
appropriate length for setting out and removal of same and the length of
the pile to be embedded in the pile cap etc. by percussion drilling using
direct mud circulation ( DMC) or bailer and chisel technique by tripod and
mechanical winch machine all complete , including removal of excavated
earth with all lifts and leads (Length of pile for payment shall be measured
upto bottom of pile cap). Tuck mounted rotary / TMR / tube well boring
machine shall not be used.

2.03 CPWD 20.3.1 Boring, Providing and installing cast in situ single under reamed piles of metre 726.00 2,123.15 1,541,407
DSR 2014 300mm diameter and length below pile cap in M-25 cement concrete, to
carry a safe working load not less than specified, excluding the cost of steel
reinforcement but including the cost of boring with bentonite solution and
the length of the pile to be embedded in pile cap etc. all complete. (Length
of pile for payment shall be measured upto to the bottom of pile cap) :

2.04 CPWD 20.6.1.2 Carrying out routine Vertical load testing on single pile upto 50 tonne in per test 6.00 17,422.50 104,535
DSR 2014 accordance with IS 2911 (Part IV) including installation of loading platform
by Kentledge method and preparation of pile head or construction of test
cap and dismantling of test cap after tests etc. complete as per
specifications and the direction of engineer in charge ( Test load 1.5 times
the safe capacity)

128
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.05 CPWD 20.6.2.2 Carrying out routine Vertical load testing on single pile above 50 tonne to per test 3.00 26,714.50 80,144
DSR 2014 100 tonne in accordance with IS 2911 (Part IV) including installation of
loading platform by kentledge method and preparation of pile head or
construction of test cap and dismantling of test cap after test etc. complete
as per specifications and the direction of engineer in charge. ( Test load 1.5
times the safe capacity)
2.06 CPWD 20.9 Integrity testing of pile using Low Strain/Sonic Integrity Test/Sonic Echo Test Per test 127.00 745.50 94,679
DSR 2014 method in accordance with IS 14893 including surface preparation of pile
top by removing mud, dust & chipping lean concrete lumps etc. and use of
computerized equipment and high skill trained personal for conducting the
test & submission of results, all complete as per direction of engineer-in-
charge.
2.07 CPWD derived Dismantling / Breaking top portion of concrete piles up to pile cut off level cum 119.58 1,302.30 155,729
DSR 2014 from 15.3 and removing rubbish/spoil up to a lead of 50m with all lifts, cleaning top
portion of pile cleaning reinforcement exposed due to breaking of pile top,
bending pile reinforcement into pile cap as per drawing and instruction of
engineer.

Total of Subhead-2 26,848,541

3.00 SH 3 ANTITERMITE TREATMENT -

3.01 CPWD 2.34.1 Supplying chemical emulsion in sealed containers including delivery as litre 167.00 168.83 28,195
DSR 2014 specified - chloryphos / Lindane emulsifiable concentrate of 20%

3.02 CPWD derived Diluting and injection chemical emulsion (to be supplied free of cost at site Sqm 835.05 115.30 96,281
DSR 2014 '2.35.1+ of work) for pre-constructional. Anti termite treatment and creating a
2.35.2+ continuous chemical barrier as per IS : 6313 part II 1981 under and all-round
2.35.3 the column pits, wall trenches, basement excavation, top surface of plinth
filling, junction of wall and floor along the external perimeter of building,
expansion joints, over the top surface of consolidated earth on which apron
is to be laid, surrounding of pipes and conduits etc., complete as
specifications (plinth area of the building at ground floor only shall be
measured for payment) Chlorpyriphos Emulsifiable concentrate 20% with 1%
concentration.
Total of Subhead-3 - 124,476

129
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

4.00 SH-4 PLAIN CEMENT CONCRETE WORK -

4.01 CPWD 4.20 Providing and laying in position ready mix plain cement concrete, with -
DSR 2014 cement content as per approved design mix and manufacture in fully
automatic batching plant and transported to site of work in transit mixer for
all leads, having continuous agitated mixer, manufactured as per mix design
of specific grade for plain cement concrete work, including pumping of RMC
from transit mixer to site of laying i/c curing excluding cost of centering and
shuttering and finishing i/c cost of curing, admixtures in recommended
portion as per IS 9103 to accelerate / retard setting of concrete , improve
workability without impairing strength and durability as per the directions of
engineer in charge.

Note : (1) Excess or less cement used in this item is payable / recoverable -
separately.

4.1.1 CPWD 4.20.1 All works upto plinth level -


DSR 2014

4.1.1.1 CPWD 4.20.1.2 M10 grade plain cement concrete ( cement content considered @ 220 kg cum 405.11 4,964.75 2,011,270
DSR 2014 per cum)

Total of Subhead-4 - 2,011,270

5.00 SH-5 REINFORCED CEMENT CONCRETE WORK -

RMC - -

130
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
5.01 CPWD 5.40 Providing and laying in position ready mix M25 grade concrete for reinforced - -
DSR 2014 cement concrete work, using fly ash and cement content as per approved
design mix and manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads, having continuous
agitated mixer, manufactured as per mix design of specific grade for plain
cement concrete work, including pumping of RMC from transit mixer to site
of laying i/c curing excluding cost of centering and shuttering and finishing
i/c cost of curing, admixtures in recommended portion as per IS9103 to
accelerate / retard setting of concrete , improve workability without
impairing strength and durability as per the directions of engineer in charge.
cement content considered in this item is @ 330 kg per cum of concrete.
Note : (1) Excess or less cement used as per design mix is payable /
recoverable separately. 2. Fly ash confirming to grade I of IS 3812 ( Part 1)
only be used as part replacement of OPC as per IS 456. Uniform blending
with cement is to ensured in accordance with clause 5.2 and 5.2.1 of IS 456-
2000 in the items of B.M.C and R.M.C.

5.1.1 CPWD 5.40.1 All works upto plinth level cum 3,046.00 6,561.20 19,985,415
DSR 2014

5.1.2 CPWD 5.40.2 All works above plinth level and upto floor V level cum 4,289.10 7,279.60 31,222,932
DSR 2014

5.02 CPWD 5.34.1 Extra for providing richer mixes at all floor levels for providing M-30 grade cum 322.33 76.50 24,658
DSR 2014 concrete in place of M-25 grade B.M.C./R.M.C. ( cement content
considered in M30 @ 340kg. per cum of concrete)

5.03 CPWD 5.34.2 Extra for providing richer mixes at all floor levels for providing M-35 grade cum 2,839.49 152.95 434,300
DSR 2014 concrete in place of M-25 grade B.M.C./R.M.C. ( cement content
considered in M35 @ 350kg. per cum of concrete)

5.04 CPWD 5.38 Extra for R.C.C. / B.M.C. / R.M.C. work above floor V level for each four floors cum 3,180.17 174.20 553,986
DSR 2014 or part there of.

5.05 CPWD 5.13 Providing, hoisting and fixing upto floor five level pre cast reinforced cum 60.28 8,797.80 530,331
DSR 2014 concrete work in small lintels not exceeding 1.5 M clear span including cost
of required centering & shuttering but excluding the cost of
reinforcement1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 20mm
nominal size)

131
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
5.06 CPWD 5.15 Providing, hoisting and fixing upto floor five level pre cast reinforced cum 10.00 8,191.40 81,914
DSR 2014 concrete in lintels, beams and bressumers including setting in cement mortar
1:3 ( 1 cement : 3 coarse sand ) cost of required centering , shuttering
complete but excluding the cost of reinforcement with 1:2:4 ( 1 cement : 2
coarse sand : 4 stone aggregate 20mm nominal size) .

5.07 NS AR-03 Providing and fixing in position 50 mm thick armor board of 32 - 36kg/m3 sqm 289.56 594.20 172,057
density in expansion joints at all heights and levels as shown in the drawing
and direction of Project Manager including cost of primer/adhesive etc.
complete.
Total of Subhead-5 - 53,005,593

6.00 SH-6 FORM WORK -


6.01 CPWD 5.9.1 Centering and shuttering for foundations, footings, bases of columns etc. for sqm 438.80 196.45 86,202
DSR 2014 mass concrete including strutting, propping, oiling, etc. removal of form work.

6.02 CPWD 5.9.2 Centering and shuttering for walls ( any thickness) including attached sqm 1,908.00 360.80 688,406
DSR 2014 pilasters, buttresses, plinth and string courses including strutting, propping,
oiling, etc. removal of form work.

6.03 CPWD 5.9.3 Centering and shuttering for suspended floors, roofs, landings, balconies and sqm 15,476.52 401.65 6,216,144
DSR 2014 access platform including strutting, propping, oiling, etc. removal of form
work.

6.04 CPWD 5.9.4 Centering and shuttering for shelves ( cast in situ) including strutting, sqm 176.40 401.65 70,851
DSR 2014 propping, oiling, etc. removal of form work.

6.05 CPWD 5.9.5 Centering and shuttering for lintels, beams, plinth beams, girders, bressumers sqm 10,317.68 332.15 3,427,017
DSR 2014 and cantilevers including strutting, propping, oiling, etc. removal of form
work.
6.06 CPWD 5.9.6 Centering and shuttering for columns, pillars, piers, abutments, posts and sqm 15,526.51 453.35 7,038,943
DSR 2014 struts including strutting, propping, oiling, etc. removal of form work.

6.07 CPWD 5.9.7 Centering and shuttering for stairs (excluding landing) except spiral staircases sqm 1,399.17 395.65 553,582
DSR 2014 including strutting, propping, oiling, etc. removal of form work.

132
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.08 CPWD 5.9.16.1 Centering and shuttering for edges of slabs and breaks in floors and walls Metre 555.00 116.40 64,602
DSR 2014 upto 20cm width including strutting, propping, oiling, etc. removal of form
work.

6.09 CPWD 5.11.1 Extra for additional height in centering, shuttering wherever required for sqm 4,421.90 159.05 703,303
DSR 2014 suspended floors, roofs, landings, beams and balconies ( plan area to be
measured ) with adequate bracing, propping etc. including cost of de-
shuttering and de-centering at all levels, over a height of 3.5m, for additional
height of 1 Metre or part thereof ( plan area to be measured )

Total of Subhead-6 - 18,849,052

7.00 SH-7 STEEL REINFORCEMENT WORK -

7.01 UPPWD Derived Providing and fixing Thermo-mechanically treated MS bars reinforcement for kg 371,712.00 68.90 25,610,957
SOR 2014 from 504 R.C.C. work including straightening, cutting, bending, placing in position and
binding complete upto plinth level. - Fe 500

7.02 UPPWD Derived Providing and fixing Thermo-mechanically treated MS bars reinforcement for kg 769,670.00 68.90 53,030,263
SOR 2014 from 504 R.C.C. work including straightening, cutting, bending, placing in position and
binding complete above plinth level. - - Fe 500

Total of Subhead-7 - 78,641,220

8.00 SH-8 BRICK WORK -

8.01 UPPWD 303 First class brick work in 1:6 cement and fine sand of 1.25 fineness modulus cum 48.75 4,850.00 236,438
SOR 2014 mortar in foundation and plinth including supply of all materials, labour and
tools and plants etc. required for proper completion of the work.

133
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.02 UPPWD 310 As in item (303) above but in super structure above including necessary cum 1,856.30 5,050.00 9,374,315
SOR 2014 cutting and moulding of brick work as required and also including honey
combed brick in thickness of wall of one brick thick add for extra labour.

First floor

8.2.1 UPPWD note Increase in As in item (303) above but in super structure above including cum 98.49 50.50 4,974
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Second floor

8.2.2 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 101.00 10,329
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Third floor

8.2.3 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 151.50 15,494
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fourth floor

8.2.4 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 202.00 20,659
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fifth floor

8.2.5 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 252.50 25,823
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Sixth floor

134
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.2.6 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 303.00 30,988
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Seventh floor

8.2.7 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 353.50 36,152
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Eighth floor

8.2.8 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 404.00 41,317
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Ninth floor

8.2.9 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 454.50 46,482
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Tenth floor

8.2.10 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 505.00 51,646
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Eleventh floor

8.2.11 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 555.50 56,811
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Twelveth floor

135
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.2.12 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 606.00 61,976
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Thirteenth floor

8.2.13 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 656.50 67,140
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fourteenth floor

8.2.14 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 707.00 72,305
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fifteenth floor

8.2.15 UPPWD note Increase in As in item (303) above but in super structure above including cum 102.27 757.50 77,470
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Sixteenth floor

8.2.16 UPPWD note Increase in As in item (303) above but in super structure above including cum 140.86 808.00 113,815
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Seventeenth floor

8.2.17 UPPWD note Increase in As in item (303) above but in super structure above including cum 82.94 858.50 71,204
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

136
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.03 UPPWD 310(a) As in item (303) above but in super structure above including necessary cum 559.59 5,150.00 2,881,889
SOR 2014 cutting and moulding of brick work as required and also including honey
combed brick in thickness of wall of half brick (4.1/2")thick. Add for extra
labour over item no. 310 of one brick thick add for extra labour.

First floor

8.3.1 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 51.50 1,909
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Second floor

8.3.2 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 103.00 3,818
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Third floor

8.3.3 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 154.50 5,727
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fourth floor

8.3.4 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 206.00 7,636
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fifth floor

8.3.5 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 257.50 9,546
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

137
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Sixth floor

8.3.6 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 309.00 11,455
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Seventh floor

8.3.7 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 360.50 13,364
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Eighth floor
8.3.8 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 412.00 15,273
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.
Ninth floor
8.3.9 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 463.50 17,182
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Tenth floor

8.3.10 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 515.00 19,091
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Eleventh floor

8.3.11 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 566.50 21,000
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

138
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Twelveth floor

8.3.12 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 618.00 22,909
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Thirteenth floor

8.3.13 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 669.50 24,818
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fourteenth floor
8.3.14 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 721.00 26,727
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Fifteenth floor

8.3.15 UPPWD note Increase in As in item (303) above but in super structure above including cum 37.07 772.50 28,637
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

Sixteenth floor

8.3.16 UPPWD note Increase in As in item (303) above but in super structure above including cum 3.46 824.00 2,851
SOR 2014 necessary cutting and moulding of brick work as required and also including
honey combed brick in thickness of wall of one brick thick add for extra
labour.

8.04 CPWD 6.15 Extra for providing and placing in position 2 nos. 6mm dia M.S. bars at every sqm 4,865.97 69.50 338,185
DSR 2014 third course of half brick masonry with FPS bricks in superstructure above
plinth level up to floor V level

Total of Subhead-8 - 13,867,354

139
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.00 SH-9 WATER-PROOFING OF RAFT, RETAINING WALL, DECK SLAB, ROOFS, INTERNAL WET AREAS
BASEMENT & UNDERGROUND STRUCTURES WATER-PROOFING -
RAFT & VERTICAL SURFACES -
Waterproofing of Raft:
9.01 NS AR-05 Supplying and installing membrane waterproofing treatment for Raft Slab , sqm 4,124.88 1,987.21 8,197,003
1.2mm thick fully bonded HDPE sheet membrane "Preprufe 300 R " or
equivalent approved make before casting of base RCC slab. The pre-
applied, fully bonded HDPE sheet membrane gets bonded to the
underneath of the poured concrete used as base/ raft slab. The fully bonded
HDPE sheet membrane shall consist of a thick HDPE film, a highly aggressive
pressure sensitive adhesive and weather resisting coating which bonds
integrally to poured concrete of base slab. The membrane shall be BBA
certified and conforms to basement waterproofing protection to grades 2, 3
as defined in BS 8102:2009. The fully bonded HDPE sheet waterproofing
membrane shall have following minimum properties : 1) Resist hydrostatic
pressure of upto 70 m head of water as per ASTM D5385; 2) Puncture
Resistance of 990 N 3) Adhesion to concrete of 2.88 N/mm. The fully bonded
HDPE sheet membrane, shall be installed with standard 75mm side edge laps
and 75mm end laps taped with Tape HC, a double side coated adhesive
tape over the entire area and turned up on to a vertical timber. The
membrane shall be laid over the concrete blinding having smooth dried
surface including necessary removal of release liner while applying,
necessary overlaps between the membranes and fixing overlaps by Tape,
firm rolling onto the surface to get a tight seal, etc. All systems to be installed
as per approved manufacturer's recommendations, etc. complete with all
lead and lift for all materials and labour and as directed by Engineer in-
charge. Refer drawing.
Waterproofing treatment to Construction joints in walls / floors -

9.02 CPWD 22.4.1 providing and placing in position suitable PVC water stops Serrated with Metre 251.49 490.20 123,280
DSR 2014 central bulb ( 225 mm wide, 8-11 mm thick) conforming to IS : 12200 of Deep
Jyoti or equivalent for construction / expansion joints between two RCC
members and fixed to the reinforcement with binding wire before pouring
concrete etc. complete.

Waterproofing of Retaining Wall: -

140
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.03 NS AR-08 Supplying and Installing self adhesive, cold applied , flexible 1.5mm thick sqm 1,150.57 1,284.48 1,477,884
waterproofing membrane " Bituthene 8000" or equivalent approved make
comprising of a self adhesive rubberized asphalt with cross laminated HDPE
film with a unique solar reflective film on top surface . The membrane shall
have pre-marked overlaps of 50mm and shall be applied on the uniform
concrete surface. The self adhesive membrane shall be BBA certified and
confirm to all grades of BS 8102:2009 and shall have following minimum
properties : (i)  Puncture resistance of 290N (ii) Resistance to Hydrostatic
head of 70m (ASTM D 5385) (iii) Should be resistant to Sulphates, Nitrates and
salt in soil. For membrane termination: Make 25mm x 25mm chase/rebate on
the vertical wall for termination of the membrane. The chase/rebate shall be
adequately sealed with approved material. All systems to be installed as per
approved manufacturer's recommendations, etc. complete with all lead
and lift for all materials and labour and as directed by Engineer in-charge as
per drawings. system shall be guaranteed for 10 years on Rs 100/- stamp
paper.

9.04 NS AR-09 Providing and fixing HDPE protection board on vertical surfaces with sqm 1,150.57 230.00 264,631
adhesives i/c cost of overlaps @ 10% as protection of waterproofing.(NS-AR)

SUNKEN AREA WATERPROOFING - -

9.05 CPWD 22.5 Providing and laying water proofing treatment in sunken portion of WCs, sqm 3,734.85 283.10 1,057,336
DSR 2014 bathroom etc., by applying cement slurry mixed with water proofing cement
compound consisting of applying : (a) Ist layer of slurry of cement @ 0.488
kg/sqm mixed with water proofing compound @0.253 kg/per sqm. This layer
will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @
0.242 kg/sqm mixed with water proofing compound @0.126 kg/sqm. This
layer will be allowed to air cure for 4 hours followed with water curing for 48
hours. The rate includes preparation of surface, treatment and sealing of all
joints, corners, junction of pipes and masonry with polymer mixed slurry.

9.06 CPWD 13.6.1 20 mm cement plaster of mix Cement mortar 1:4. to protect the sqm 3,734.85 242.05 904,020
DSR 2014 waterproofing

141
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ROOF WATERPROOFING -
9.07 CPWD 22.7.1 Providing and laying integral cement based water proofing treatment sqm 824.83 1,019.05 840,543
DSR 2014 including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations: a) Applying a slurry
coat of neat cement using 2.75 kg/sqm of cement admixed with water
proofing compound conforming to IS. 2645 and approved by Engineer-in-
charge over the RCC slab including adjoining walls upto 300 mm height
including cleaning the surface before treatment. b) Laying brick bats with
mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of
cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge
over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand
) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and treating similarly the
adjoining walls upto 300 mm height including rounding of junctions of walls
and slabs
c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the
surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing compound conforming to IS :
2645 and approved by Engineer-in-charge including laying glass fibre cloth
of approved quality in top layer of plaster and finally finishing the surface
with trowel with neat cement slurry and making pattern of 300x300mm
square 3 mm deep. e) The whole terrace so finished shall be flooded with
water for a minimum period of two weeks for curing and for final test. All
above operations to be done in order and as directed and specified by the
Engineer-in-Charge :..With average thickness of 120 mm and minimum
thickness at khurra as 65 mm.
9.08 NS AR-14 Providing and fixing aluminum flashing , wherever required for termination of Metre 556.81 495.00 275,621
Bituthene membrane at all locations . Item shall include rates for membrane
termination on the Vertical parapet wall at height as specified in drawings
for termination of the membrane.

9.09 NS AR-15 Providing and applying sealing penetration of PVC sleeves of 150mm all- each 21.00 1,744.80 36,641
round on the "Preprufe" membrane with a 2 component liquid membrane /
Bituthene LM, 25mm x 20mm size ADCOR 500S wrapped around pipe of any
dia as per drawing after fixing of double sides Preprufe tape HC complete .

142
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Waterproofing Treatment for Landscaping Decks and Landscape Roofs -

9.10 CPWD 22.19 Providing and laying APP (Atactic Polypropylene Polymer) modified sqm 2,917.41 407.50 1,188,845
DSR 2014 prefabricated five layer, 3mm thick water proofing membrane, black finished
reinforced with glass fibre matt consisting of a coat of bitumen primer for
bitumen membrane @ 0.40ltr/sq.mt by the same membrane manufactured
of density @25°C, 0.87-0.89 kg/litre and viscosity 70-160 cps. Over the primer
coat the layer of membrane shall be laid using Butane torch and sealing all
joints etc. and preparing the surfaces complete. The vital physical and
chemical parameters of the membrane shall be - Joint strength in
longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength
in longitudinal and transverse direction as 60/80N. Softening point of
membrane not less then 150° C. cold flexibility shall be upto -2°C when tested
in accordance with ASTM, D_5147. The laying of membrane shall be got
done through the authorized applicator of the manufacturer of membrane.

9.11 CPWD 22.21 Extra for covering top of membrane with Geotextile, 120gsm non Woven, sqm 2,917.41 74.85 218,368
DSR 2014 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with
intermitted touch by heating the membrane by Butane torch as per
manufacturers recommendation [ for the item No. 22.18 to 22.20 ]

Protection on Terrace Waterproofing -

9.12 CPWD 4.20.2.1 Providing and laying in position ready mix plain cement concrete M15 cum 280.67 6,540.90 1,835,834
DSR 2014 GRADE , with cement content as per approved design mix and manufacture
in fully automatic batching plant and transported to site of work in transit
mixer for all leads, having continuous agitated mixer, manufactured as per
mix design of specific grade for plain cement concrete work, including
pumping of RMC from transit mixer to site of laying i/c curing excluding cost
of centering and shuttering and finishing i/c cost of curing, admixtures in
recommended portion as per IS 9103 to accelerate / retard setting of
concrete , improve workability without impairing strength and durability as
per the directions of engineer in charge. MINIMUM CEMENT 240 all work
above plinth level upto level 5.
9.13 CPWD 22.14.1 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cum 41.24 5,570.55 229,729
DSR 2014 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size )

143
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.14 CPWD 12.22 Making khurras 45x45cm with average minimum thickness of 5cm cement each 21.00 186.65 3,920
DSR 2014 concrete 1:2:4 over PVC sheet 1mx1m x 400, micron finished with 12mm
cement plaster 1:3 and one coat of neat cement rounding of edges and
making and finishing the outlet complete.

Total of Subhead-9 - 16,653,656

10.00 SH10 INSULATION - OVERHEAD & UNDERDECK


10.01 CPWD 12.56 Providing and laying roof insulation with 40 mm thick impervious sprayed, sqm 708.38 1,167.20 826,821
DSR 2014 closed cell free Rigid Polyurethane foam over deck insulation conforming to
IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of
polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene
sheet over PUF spray and providing a wearing course of 40 mm thick cement
screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal
size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding
with 24 G wire netting and sealing the joints with polymerized mastic, all
complete as per direction of Engineer-in-Charge
Total of Subhead-10 - 826,821

11.00 SH-11 PLASTERING - INTERNAL AND EXTERNAL -


Wall plaster - -
11.01 UPPWD 586 12 mm thick plaster with cement mortar in proportion of 1:6 cement & fine sqm 10,662.50 109.00 1,162,213
SOR 2014 sand of 1.25 F.M.

11.02 CPWD 13.5.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:6 sqm 15,993.75 183.45 2,934,053
DSR 2014 ( 1 cement:6 coarse sand )

11.03 CPWD 13.5.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 sqm 5,308.35 183.45 973,817
DSR 2014 ( 1 cement:4 coarse sand ) in internal walls of service shafts

11.04 UPPWD 584+587 12mm cement plaster to ceiling of cement mortar mix 1:4 (1 cement : 4 fine sqm 11,461.67 137.00 1,570,249
SOR 2014 sand of 1.25 FM).

11.05 CPWD 5.30 Add or deduct for plaster drip course / groove in plastered surface or Metre 1,000.00 30.75 30,750
DSR 2014 moulding to RCC projections.

144
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
11.06 CPWD 13.11 18mm cement plaster in two coats under layer 12 mm thick cement plaster sqm 10,732.67 240.55 2,581,744
DSR 2015 1:5 ( 1cement:5 coarse sand ) finished with a top layer 6 mm thick cement
plaster 1:6 ( 1cement : 6 fine sand ).

11.07 CPWD 13.22 Extra for plastering exterior walls of height more than 10 m from ground level sqm 9,895.15 37.95 375,521
DSR 2014 for every additional height of 3 m or part thereof.

11.08 CPWD 4.18 Extra for addition of synthetic Polyester triangular fibre of length 12mm, per bag 2,146.53 53.00 113,766
DSR 2014 effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in of 50kg
cement concrete/RCC/Flooring/water retaining structures by using 125gms of cement
synthetic Polyester triangular fibre for 50 Kg cement used as per directions of
Engineer-in-Charge.

11.09 CPWD 7.23.2.5 30mm thick white sand stone work (machine cut edges) -exposed face Sqm. 1,074.00 3,036.60 3,261,308
DSR 2014 machine cut and table rubbed with rough backing for wall lining etc.
(veneer work) backing filled with a grout of 12 mm thick cement mortar 1:3
(1 cement :3 coarse sand) including pointing in with white cement mortar 1:2
( 1 white cement : 2 stone dust) with an admixture of pigment matching the
stone shade. ( To be secured to the backing by means of cramps shall be
paid for separately )

11.10 CPWD 7.32.2 White sand stone work, plain in copings, cornices, string course and plinth cum 33.00 39,022.00 1,287,726
DSR 2014 courses in cement mortar 1:6 ( 1 cement : 6 coarse sand) including pointing
with white cement pointing with white cement mortar 1:2 ( 1 white cement:2
stone dust) with an admixture of pigment matching the stone shade.

Total of Subhead-11 - 14,291,147

145
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
12.00 SH-12 STEEL & STRUCTURAL STEEL WORKS -

12.01 CPWD 7.41 Providing and fixing structural steel frame ( for dry cladding with 30mm thick Kg 30,800.00 143.55 4,421,340
DSR 2014 gang saw cut with machine cut edges sand stone ) on walls at all heights
using M.S. square / rectangular tube in the required pattern as per
architectural drawing including cost of cutting, bending, welding etc. The
frame work shall be supported in wall with the help of MS brackets / lugs of
angle iron / flats etc. which shall be welded to the frame and embedded in
brick wall with cement concrete block 1:2:4 ( 1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) of size 300x230x300mm
including necessary cost of centering and shuttering and with approved
expansion hold fasteners on CC / RCC surface including drilling necessary
holes. Approved cramps / pins etc. shall be welded to the frame work to
support stone cladding the steel work will be given a priming coat of Zinc
primer as approved by Engineer-in-charge and painted with two or more
coats of epoxy paint ( shop drawings shall be submitted by the contractor to
the Engineer-in-charge for approval before execution). The frame work shall
be fixed in true horizontal & vertical lines / planes. ( Only structural steel
frame work shall be measured for the purpose of payment, stainless steel
cramps shall be paid for separately and nothing extra shall be paid ).

12.02 CPWD 10.25 Steel work welded in built up sections/ framed work including cutting, - -
DSR 2014 hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.

12.2.1 CPWD 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar kg 48,286.00 90.10 4,350,569
DSR 2014 works.

12.03 NS AR P/F Hollock wood hand rail for staircase size 65mm x 120mm fixed to mild Metre 1,931.00 857.20 1,655,253
steel flat with screws i/c spirit polishing after applying wood filler.

Total of Subhead-12 - 10,427,162

146
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.00 SH 13 EXTERNAL FAÇADE WORK - ALUMINIUM, GLASS , GLASS DOORS

13.01 CPWD 26.1 Providing and supplying aluminium extruded tubular and other aluminium kg 189.00 338.25 63,929
DSR 2014 sections as per the architectural drawings and approved shop drawings , the
aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super
durable powder coating of 60-80 microns conforming to AAMA 2604 of
required colour and shade as approved by the Engineer-in-Charge. ( The
item includes cost of material such as cleats, sleeves, screws etc. necessary
for fabrication of extruded aluminium frame work. Nothing extra shall be
paid on this account).

13.02 CPWD 26.2 Designing, fabricating, testing, protection, installing and fixing in position semi sqm 27.00 2,556.15 69,016
DSR 2014 (grid) unitized system of structural glazing (with open joints) for linear as well
as curvilinear portions of the building for all heights and all levels, including
Structural analysis & design and preparation of shop drawings for the
specified design loads conforming to IS 875 part III (the system must passed
the proof test at 1.5 times design wind pressure without any failure), including
functional design of the aluminum sections for fixing glazing panels of various
thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws,
toggles, nuts, bolts, clamps etc., structural and weather silicone sealants,
flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets
for water tightness, pressure equalisation & drainage and protection against
fire hazard complete as per item 26.2

147
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.03 CPWD 26.6 Providing and supplying Spandrel Glass Panels comprising of 6 mm thick sqm 27.00 2,997.25 80,926
DSR 2014 heat strengthened monolithic float glass of approved colour and shade with
reflective soft coating on surface # 2 of approved colour and shade so as to
match the colour and shade of the IGUs in the vision panels etc. ,all
complete for the required performances as specified, as per the
Architectural drawings, as per the approved shop drawings, as specified,
and as directed by the Engineer- in- Charge. For payment, only the actual
area of glass on face # 1 of the glass panels (but excluding the area of
grooves and weather silicone sealant) provided and fixed in position, shall
be measured in sqm.(Payment for fixing of Spandrel Glass Panels in the
curtain glazing is included in cost of relevant Item*). (i) Coloured tinted float
glass 6mm thick substrate with reflective soft coating on face # 2, having
properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection
internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient
(0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. . The properties of
performance
glass shall be decided by technical sanctioning authority as per the site
quirement.
13.04 NS AR Design, fabrication and installation of anodised aluminium fixed louvers with sqm 195.00 1,722.00 335,790
tubular section and outer aluminium channel frame at terrace level with m.s.
supporting structure behind as shown in concept details. Aluminium frame,
necessary hardware like s.s. nuts / bolts, frame fixing screws etc. as per the
elevation, sections and details shall be used as per drawings enclosed. 'The
aluminium louvers shall be fabricated out of heavy duty aluminium extruded
built up profiles confirming to alloy 63400 WP with chemical composition and
mechanical properties as per IS:733:1983 and IS 1285:2002. All profiles shall be
anodised in approved shade. ( aluminium quantity payable in DSR item
21.1.1)

13.05 CPWD 26.1 Providing and supplying aluminium extruded tubular and other aluminium kg 1,901.25 338.25 643,098
DSR 2014 sections for louvers as per the architectural drawings and approved shop
drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS
1474,including anodising coating AC 15 microns conforming to AAMA 2604 of
required colour and shade as approved by the Engineer-in-Charge. ( The
item includes cost of material such as cleats, sleeves, screws etc. necessary
for fabrication of extruded aluminium frame work. Nothing extra shall be
paid on this account).
Total of Subhead-13 1,192,759

148
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

14.00 SH-14 WOOD WORK - DOORS, PARTITIONS & PANELING


14.01 CPWD 9.1.1 Providing Second class Teak wood work in frames of doors, windows, cum 3.81 91,496.90 348,603
DSR 2014 clerestory windows and other frames, wrought framed and fixed in position
with hold fast lugs or dash fastener of required dia and length ( hold fast lugs
or dash fastener shall be paid for separately).

14.02 CPWD 9.1.3 Providing Kiln seasoned and chemically treated Hollock wood work in cum 16.46 53,698.60 883,879
DSR 2014 frames of doors, windows, clerestory windows and other frames, wrought
framed and fixed in position with hold fast lugs or dash fastener of required
dia and length ( hold fast lugs or dash fastener shall be paid for separately).

14.03 CPWD 9.3.2 Providing Kiln seasoned and chemically treated Hollock wood work in frames cum 4.55 48,848.40 222,260
DSR 2014 of false ceiling, partitions etc. sawn and put up in position

14.04 CPWD 9.5.1.1 Providing and fixing 35mm thick second class teak wood panelled or sqm 158.06 2,689.05 425,031
DSR 2014 panelled and glazed shutters for doors, windows and clerestory windows
including ISI marked M.S. pressed butt hinges bright finished of required size
with necessary screws excluding paneling which will be paid separately, all
complete as per direction of Engineer-in-charge.

14.05 CPWD 9.7.3.1 Providing and fixing 9mm thick decorative plywood both side decorative sqm 158.06 1,863.00 294,466
DSR 2014 veneer ( type I) conforming to IS 1328 BWR type paneling in panelled or
panelled and glazed shutters for doors, windows and clerestory windows (
area of opening for panel inserts excluding portion inside grooves or rebates
to be measured) .

14.06 CPWD 9.20.1 Providing and fixing 35mm thick ISI marked flush door shutter confirming to IS sqm 632.94 2,606.45 1,649,726
DSR 2014 : 2202 ( part I) decorative type, core of block board construction with frames
of first class hard wood and well matched teak 3 ply veneering with vertical
grains or cross bands and face veneers on both sides of shutters fixed with ISI
marked stainless steel butt hinges with necessary hinges.

14.07 CPWD 9.23 Extra for providing lipping with second class teak wood battens 25mm sqm 791.00 365.85 289,387
DSR 2014 minimum depth on all edges of shutters ( over all area of door shutter to be
measured ).

149
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
14.08 CPWD 9.40.1.1 Providing and fixing 2nd class teak wood size 50x12 mm moulded beading metre 2,416.86 117.95 285,069
DSR 2014 to door and window frames with iron screws, plugs and priming coat on
unexposed surface etc. complete.

14.09 CPWD 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with each 1,856.00 117.35 217,802
DSR 2014 10 mm diameter bolts, nuts and wooden plugs and embedding in cement
concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded
stone aggregate 20mm nominal size)

14.10 CPWD 9.14 Extra for providing ISI marked stainless steel butt hinges instead of black sqm. 158.06 253.50 40,068
DSR 2014 enameled M.S. butt hinges with necessary screws. ( shutters Area shall be
measured)

14.11 CPWD 17.31 Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of each 181.00 793.95 143,705
DSR 2014 approved quality) complete with 6 mm thick hard board ground fixed to
wooden cleats with C.P. brass screws and washers complete.

14.12 CPWD 10.27.3 Providing and fixing 10 x 120 mm carbon steel galvanised ( minimum coating each 100.00 86.75 8,675
DSR 2014 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield
strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide
PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry,
etc. as per direction of Engineer-in-charge.

Total of Subhead-14 4,808,672

15.00 SH-15 FLOORING, SKIRTING & DADO WORK

15.01 CPWD 11.6.1 Providing and laying 18mm thick Cement plaster skirting (up to 30 cm height) sqm 100.00 377.25 37,725
DSR 2014 with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating
coat of neat cement.

15.02 CPWD 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and sqm 2,456.71 1,141.40 2,804,089
DSR 2014 jointed with grey cement slurry mixed with pigment to match the shade of
the slab, including rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) : 25mm thick

150
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.03 CPWD 11.41 Providing and laying polished vitrified floor tiles in different sizes (thickness to -
DSR 2014 be specified by the manufacturer) with water absorption's less than 0.08%
and conforming IS : 15622 of approved make in all colours and shades, laid
on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) including
grouting the joints with white cement and matching pigments etc. complete.

15.3.1 CPWD 11.41.2 Size of tiles 60x60cm sqm 6,893.97 1,405.95 9,692,577
DSR 2014

15.04 CPWD 16.86.1 Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded sqm 719.14 3,148.55 2,264,248
DSR 2014 and pre polished machine cut granite stone of required size and shape of
approved shade, colour and texture in footpath, flooring cut granite stone of
required size and shape of approved shade, colour and texture in footpath,
flooring in road side plazas and similar locations, laid over 20mm thick base
of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints
with white cement mixed with matching pigment, epoxy touch ups etc.
complete as per direction of Engineer-in-Charge. stone size Area less than
0.50 sqm. ( Granite rate Rs. 1900 per sqm tax paid)

15.05 CPWD 11.48 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy
DSR 2014 grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of
hardener and 0.20 kg of resin per kg), including filling / grouting and finishing
complete as per direction of Engineer-in-charge.

15.5.1 CPWD 11.48.2 Size of Tile 600x600 mm sqm 6,893.97 187.95 1,295,722
DSR 2014

15.06 CPWD 11.37 Providing and laying ceramic glazed floor tiles 300x300mm in size ( thickness sqm 1,365.02 785.40 1,072,087
DSR 2014 to be specified by the manufacturer) of Ist quality confirming to IS : 15622 of
approved make in colours such as white, Ivory , grey , fume red brown laid
on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) including
pointing the joints with white cement and matching pigments etc. complete

15.07 CPWD 11.25 Extra for granite stone flooring in treads of steps and risers using single length sqm 70.43 320.30 22,559
DSR 2014 up to 2.00 metre.

151
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.08 NS derived Providing and fixing 18mm thick granite in skirting, riser, sills etc. for vertical sqm 47.59 3,431.00 163,281
surfaces of approved quality and shade laid over 12/15mm (AV.) thick
cement mortar 1:4 ( 1 cement : 4 coarse sand) and jointed with white
cement slurry mixed with pigment to match the granite shade etc. all
complete.

15.09 NS AR Extra for making honed finish surface of granite in treads instead of polished. sqm 470.95 223.57 105,290

15.10 CPWD 11.46 Providing and laying polished vitrified tiles in different sizes (thickness to be -
DSR 2014 specified by the manufacturer) with water absorption's less than 0.08% and
conforming IS : 15622 of approved make in all colours and shades, in skirting,
risers of steps, laid with 12mm thick cement mortar 1:3 ( 1 cement : 3 coarse
sand) including grouting the joints with white cement and matching
pigments etc. complete.

15.10.1 CPWD 11.46.2 Size of tiles 60x60cm in dado sqm 669.42 1,415.40 947,497
DSR 2014

15.11 CPWD 11.27 Providing and laying 25mm thick Kota stone slabs in skirting, dado, pillars, sqm 2,232.21 1,191.25 2,659,120
DSR 2014 risers of steps (area upto 900 sqcm) laid on 12mm thick (Avr) cement mortar
1:3 ( 1 cement : 3 coarse sand) and jointed with grey cement slurry mixed
with pigment to match the shade of stone slabs, including necessary cutting,
rubbing and polishing etc. complete.

15.12 CPWD 11.36 Providing and fixing Ist quality ceramic glazed wall tiles conforming to sqm 3,707.03 836.65 3,101,487
DSR 2014 IS:15622 (thickness to be specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white
cement mixed with pigment of matching shade complete

152
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.13 CPWD 8.2.1.2 Providing and laying 18mm thick mirror polished, machine cut marble for sqm 1,075.57 2,463.55 2,649,720
DSR 2014 kitchen platforms, vanity counters, facias, window sills and similar locations of
required size of approved shade, colour and texture laid over 20mm thick
base cement mortar 1:4 ( 1 cement : 4 coarse sand) with joints treated with
white cement mixed with matching pigment, epoxy touch ups including
rubbing, curing etc. complete at all levels. Raj Nagar plain white marble/
Udaipur green marble/ Zebra black marble -Area of slab over 0.5 sqm

15.14 CPWD 8.3.1 Providing edge moulding to 18mm thick marble stone counters, vanities etc. metre 681.30 136.10 92,725
DSR 2014 including machine polishing to edge to give high gloss finish etc. complete
as per design approved by engineer in charge.

15.15 NS AR Extra for providing and fixing 12mm thick BW plywood behind marble / metre 681.30 191.27 130,312
granite fascia upto 200mm height to fix stone with Araldite adhesive

15.16 CPWD 8.4 Extra for fixing marble / granite stone over and above corresponding item in metre 681.30 247.40 168,554
DSR 2014 facia and drops of width upto 150mm with epoxy resin based ( Araldite or
equivalent) adhesive including cleaning etc. complete

15.17 CPWD 8.5 Extra for providing opening of required size & shape for wash basins / each 242.00 386.60 93,557
DSR 2014 kitchens sink in kitchen platform, vanity counters and similar location in opening
marble / stone work including necessary holes for pillar taps etc. including
rubbing and polishing of cut edges etc. complete.

15.18 CPWD 16.75 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete cum 351.14 6,848.85 2,404,905
DSR 2014 from batching plant. The ready mixed concrete shall be laid and finished
with screed board vibrator , vacuum dewatering process and finally finished
by floating, brooming with wire brush etc. complete as per specifications
and directions of Engineer-in- charge. (The panel shuttering work shall be
paid for separately). (Note:- Cement content considered in this item is @ 330
kg/cum. Excess/less cement used as per design mix is payable/ recoverable
separately).

Total of Subhead-15 29,705,455

153
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
16.00 SH-16 FALSE CEILING WORKS
16.01 12.45 Providing and fixing at all height false ceiling including providing and fixing
of frame work made of special sections power pressed from M.S. sheet and
galvanised in accordance with zinc coating of grade 350 as per IS: 277 and
consisting of angle cleats of size 25mm wide x 1.6 mm thick wih flanges of
22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling
with dash fastener 12.5mm diax 40mm long with 6mm dia bolts to the angle
hangers of 25x25x0.55 mm of required length and other end of angle hanger
being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the
rate of 1200 mm centre to centre to which the ceiling section 0.5 mm thick
button wedge of 80 mm with tapered flanges of 26 mm each having clips of
10.5 mm at 450 mm centre to centre shall be fixed in a direction
perpendicular to G.I. channel with connecting clips made out of 2.64 mm
dia x230mm long G.I. wire at every junction including fixing the gypsum
board with ceiling section and perimeter channels 0.5 mm thick 27 mm high
having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450 mm centre to centre with 25
mm long drive all screws @ 230 mm interval including jointing and fixing to a
flush finish of tapered and square edges of the board with recommended
filler, jointing tapes, finisher and two coats of primer suitable for board as per
manufactures specification and also including the cost of making openings
for light fittings ,grills, diffusers, cutouts made with frame of perimeter
channels suitably fixed all complete as per drawing and specification and
direction of the Engineer-in-charge but excluding the cost of painting with :

16.1.1 CPWD 12.45.1 12.5 mm thick tapered edge gypsum board conforming to IS: 2095-part I. sqm 908.86 907.10 824,427
DSR 2014

16.1.2 CPWD 12.45.4 Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having sqm 275.08 1,236.35 340,095
DSR 2014 approx. 15 % perforated area with perforation size and pattern as approved
by the Engineer in-charge and as per manufacturer's specification, with all 4
side tapered and backed by acoustical tissue with NRC value not less than
0.60
Total of Subhead-16 1,164,522

154
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

17.00 SH-17 WALL FINISHES - INTERNAL & EXTERNAL


17.01 CPWD 13.26 Providing and applying plaster of Paris putty of 2mm thickness over plastered sqm 19,649.89 110.95 2,180,155
DSR 2014 surface to prepare the surface even and smooth complete.

17.02 NS AR Making groove in plaster of paris putty on walls and skirting metre 2,000.00 32.80 65,600
17.03 CPWD 13.37.1 White washing with lime to give an even shade, New work ( three or more sqm 5,308.35 16.20 85,995
DSR 2014 coats ).
17.04 CPWD 13.45.1 Finishing walls with textured exterior paint of required shade: New work ( two Sqm. 7,211.98 146.45 1,056,194
DSR 2014 or more coats applied @ 3.28 litre/10 sqm) over and including base coat of
water proofing cement paint applied @ 2.20kg/10sqm.

17.05 CPWD 13.68.1 French spirit polishing two or more coats on new works including a coat of sqm 460.89 193.95 89,390
DSR 2014 wood filler.

17.06 CPWD 13.81.2 Distempering two with 1st quality acrylic distemper, having VOC (Volatile sqm 27,470.84 45.70 1,255,417
DSR 2014 Organic Compound ) content less than 50 grams/ litre, of approved brand
and manufacture, including applying additional coats wherever required, to
achieve even shade and colour.

17.07 CPWD 13.83.2 Wall painting two coats with premium acrylic emulsion paint of interior sqm 5,804.00 75.35 437,331
DSR 2014 grade, having VOC (Volatile Organic Compound ) content less than 50
grams/ litre of approved brand and manufacture, including applying
additional coats wherever required to achieve even shade and colour.

17.08 CPWD 13.84.2 Painting with two coats synthetic enamel paint, having VOC (Volatile sqm 1,757.50 71.60 125,837
DSR 2014 Organic Compound) content less than 150 grams/ litre, of approved brand
and manufacture, including applying additional coats wherever required to
achieve even shade and colour.

17.09 NS AR Providing and applying of 2 coats of exterior Metallic paint of approved sqm 3,473.13 270.00 937,745
shade in silver finish i/c applying wall care putty, exterior wall primer on walls
as per specifications complete.

17.10 CPWD 13.85.1 Applying priming coats with ready mixed pink or grey primer on wood work sqm 1,757.50 36.10 63,446
DSR 2014 (hard and soft wood) having VOC content less than 50 grams/ litre of
approved brand and manufacture.

155
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Total of Subhead-17 6,297,111

18.00 SH-18 ALUMINIUM WORK - DOOR, WINDOWS


18.01 CPWD 21.1 Providing, fixing, supplying, installation and design of aluminium work for -
DSR 2014 doors, windows, ventilators and partitions with extruded built up standard
tubular sections/appropriate Z sections and other sections of approved
make confirming to IS: 733 and IS: 1285 fixed with rawl plugs and screws or
with fixing clips or with expansion hold fasteners including necessary filling up
of gaps at junctions, at top , bottom and sides with required PVC / neoprene
felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including cleat angle, aluminium
snap beading for glazing / paneling, CP brass / SS screws all complete as per
architectural drawings and the direction of Engineer-in-charge.(Glazing and
paneling to be paid for separately):
18.1.1 CPWD 21.1.1.1 Fixed Windows -Anodised aluminium (anodised transparent or dyed to kg 67.00 348.50 23,350
DSR 2014 required shade according to IS: 1868, Minimum anodic coating of grade AC
15)
18.1.2 CPWD 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade kg 28,280.00 405.90 11,478,852
DSR 2014 according to IS: 1868, Minimum anodic coating of grade AC 15) -For shutters
of doors, windows & ventilators including providing and fixing hinges/ pivots
and making provision for fixing of fittings wherever required including the
cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for
separately)
18.02 CPWD 21.8.1 Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone metre 5,289.00 88.75 469,399
DSR 2014 work Upto 5mm depth and 5 mm width by providing weather silicon sealant
over backer rod of approved quality as per architectural drawings and
direction of Engineer-in-charge.

18.03 CPWD 21.11.3 Providing and fixing stainless steel ( SS304 grade ) adjustable friction windows each 676.00 350.70 237,073
DSR 2014 stays 355 x 19 mm of approved quality with necessary stainless steel screws
etc. to the side hung windows as per direction of Engineer-in-charge
complete.
18.04 CPWD 21.11.2 Providing and fixing stainless steel ( SS304 grade ) adjustable friction windows each 480.00 275.25 132,120
DSR 2014 stays 255 x 19 mm of approved quality with necessary stainless steel screws
etc. to the side hung windows as per direction of Engineer-in-charge
complete.

156
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
18.05 CPWD 21.3.2 Providing and fixing 6mm clear float glass glazing in aluminium doors, sqm 2,455.89 1,054.20 2,588,999
DSR 2014 window, ventilators, shutters and partition etc. with PVC / neoprene gasket
etc. complete as per architectural drawing and the direction of the Engineer-
in-charge. ( cost of aluminium snap beading shall be paid in basic items.)

18.06 CPWD derived Extra for toughening of 4/5/6mm thick clear glass pane sqm 2,455.89 290.40 713,190
DSR 2014 DSR
18.07 CPWD 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to kg 4,178.00 312.20 1,304,372
DSR 2014 required shade according to IS: 1868, Minimum anodic coating of grade AC
15) sub frame work for windows and ventilators with extruded built up
standard tubular sections of approved make conforming to IS: 733 and IS:
1285 fixed with rawl plugs and stainless steel screws etc.

18.08 CPWD 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of sqm 7.44 4,746.25 35,312
DSR 2014 approved brand and manufacture, including providing and fixing top &
bottom pivot & spring type fixing arrangement and making necessary holes
etc. for fixing required door fittings, all complete as per direction of Engineer-
in-charge (Door handle, lock and stopper etc.to be paid separately).

18.09 NS AR Providing and fixing of 2.45m high frameless 12mm thick clear toughened sqm 54.93 4,802.00 263,774
glass fixed glazing inside the building fixed at top with S.S. brackets 316
grade, including cost of making suitable holes in the glass for installation
complete in position in all respects as per concept drawings enclosed. The
periphery of the glazing shall be sealed both from inside and outside with
silicone weather sealant to make the glazing's water/airtight with 2mm thk
mill finish aluminium peripheral channel. Glass to glass joints shall be filled
with clear substrate silicon to have a neat and clean appearance. Silicone
sealant of approved make/grade shall be used as per recommended by the
silicon manufacturer. Warranty for silicone adhesion shall be submitted to the
architect/engineer in charge on completion of the works by the contractor
to cover all risks against any failure of glass for a period of 10 years. The
glazing shall be aligned for height and width respectively by lazer beam
equipment to ensure 100 percent 'X' axis and 'Y' axis alignment. The item
above includes design including labour's, tools, lifting machines/cranes etc.
including cost of sealants, s.s. brackets, fasteners, screws, sleeves, spacers,
protective tape, masking tape, backer rods, bolts, gasket, fixtures,
scaffolding, etc. complete in all respect.

157
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
18.10 CPWD 10.29.2 Providing & fixing fly proof Wire gauze with stainless steel ( grade 304 ) wire Sqm 1,396.73 1,277.60 1,784,462
DSR 2014 gauze of 0.5mm dia wire and 1.4 mm aperture on both sides to windows,
clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.

Total of Subhead-18 19,030,903

19.00 SH-19 FIRE DOORS & ACCESSORIES

19.01 NS AR Supply and fixing of Interlayered FR Glass of Saint-Gobain, Torch, Glaberwel no. 78.00 6,998.00 545,844
make minimum 11 mm thick interlayered , 120 minutes fire Rated (EW120, EI
15 minutes ) Non Wired, Toughened Interlayered Glass of approved make
which can also withstand thermal shock upto 800 degree centigrade shall be
used as a glazing (Vision Panel Top/side fixed glazing) and is to be fixed in
between the glass beading by using ceramic fiber in accordance with BS :
476 Part 22/ EN 1363 EN 1364 for stability and integrity of size 300 mm x 500mm
(Clear vision ) and the manufacturer should have tested the glass of similar or
bigger size with any type of door framing from CBRI Roorkee . The Location of
the Fr Glass will be as per the directions of Engineer-in-charge ( Actual Glass
size will be measured for payment).

19.02 NS AR Supply and fixing of Hollock wood - door frame of section 120 mm x 70 mm metre 418.36 1,350.00 564,786
with heat activated intumescent fire seal strip of section 10 mm x 4 mm 2 no.
of Sealz, Fire & Acoustic , Viper make . The frame is duly primer with FR
retardant primer FR880 type primer and FR Paint FRS type. The frame should
be fixed in existing opening with thr help of anchor fastener of appropriate
size as per direction of Engineer in Charge. The manufacturer should be an
ISO certified and IGBC registered member. The approved manufacturer are
Navair , Promat , Godrej , Shakatimet .

158
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.03 NS AR Providing and fixing of 52mm thick Wooden fire rated door shutters tested as
per BS:476 Part- 20 & 22 & IS 3614 Part-2 for stability, integrity and thermal
insulation. Recommended fire door shall have doors tested at CBRI vide test
report FR No. 0291 for maximum rating of 2hrs tested either with or without
vision panel. Individual Test certificates should be available for glass used in
vision lites confirming the required fire ratings. The shutter should be
maximum 52 mm thick upto commercial ply facing and lamination , if
required should be over and above . The core insulation should be asbestos
free comprising of two 12 mm thick Calcium Silicate boards of Pamtech
type , a 100% without Asbestos, having density not more than 900Kg/M3 and
thermal conductivity 0.14 W/m*K with non-combustibility as per BS 476 part 4-
1970 and class-1 surface spread as per BS-476 Part-7-1971 . These boards
sandwiching 20 mm thick fire resistance insulation filler faced with 03 mm
thick commercial ply facing on both faces .. the shutter is provided with heat
activated intumescent fire seal strip of size 20mm x 4 mm mounted in the
grooves of 2nd class teak wood Exposed lipping on all sides except bottom.
The intumescent fire retardant sealant should be used to fill the gaps
between civil opening and frame along with wool insulation so as to fill any
visible gap . The manufacturer should submit desired design test report for a
design tested earlier for 120 minutes fire rating along with Vision Panel tested
at CBRI Roorkee as per direction's of Engineer in Charge. The manufacturer
should be an ISO certified and IGBC registered member. The approved
manufacturer are Navair , Promat , Godrej , Shakatimet .
19.3.1 NS AR Door Shutter with Paint Finish FD - 95 no. doors sqm 157.84 5,681.00 896,689

19.04 NS AR Supply & fixing of SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with each 312.00 361.00 112,632
SS Screws of BB1953 Becker F.S / 3090F DORMA / 8011008 GEZE Make ( 4 Nos
per panel ) (Required For All Doors)

19.05 NS AR Supply & fixing of SS D Type Pull Handle of size 300mm mm Long of PHD2230 each 156.00 550.00 85,800
Becker F.S/ 8133006 GEZE/ TGDI30022 DORMA Make.

19.06 NS AR Supply & fixing of door closers of BLC-0408 Becker F.S/ TS-73V DORMA / TS2000 each 78.00 4,260.00 332,280
GEZE Make. (Required For All Fire Door)

159
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.07 NS AR Supply & fixing of anchor fasteners of HILTI/ FISHER/ Equivalent of maximum each 702.00 97.00 68,094
120mm length.

19.08 CPWD 13.58 Providing and applying two coats of fire retardant paint unthinned on sqm 315.68 247.65 78,178
DSR 2014 cleaned wood/ply surface @ 3.5 sqm per litre per coat including
preparation of base surface as per recommendations of manufacturer to
make the surface fire retardant.

Total of Subhead-19 2,684,303

20.00 SH20 STAINLESS STEEL & GLASS RAILING WORKS

20.01 CPWD 10.28 Providing and fixing stainless steel (Grade 304) railing (1.0m high from F.F.L. as kg 6,869.00 619.40 4,254,659
DSR 2014 per concept detail drawings) made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary stainless steel nuts
and bolts complete, i/c fixing the railing with necessary accessories &
stainless steel dash fasteners , stainless steel bolts etc., of required size, on the
top of the floor or the side of waist slab with suitable arrangement as per
approval of Engineer-in-charge, (for payment purpose only weight of
stainless steel members shall be considered excluding fixing accessories such
as nuts, bolts, fasteners etc.). Laminated glass shall be paid separately under
item.

20.02 NS AR Providing, fixing, supplying and installation of glass GL7 =6mm thick clear Metre 964.69 4,246.00 4,096,074
toughened glass + 1.52 mm thick PVB Lamination + 6mm. Thick clear
toughened glass as per approved ( 750mm in height glass), glass as per
approved sample fixed in position on to grade 304 S.S. balusters and
connectors with S.S. handrail as per concept detail drawings enclosed. 'The
item includes required holes, Labour, scaffolding, sales tax / VAT, excise duty
etc. complete in all respect. All S.S. items shall be paid separately.

Total of Subhead-20 8,350,732

160
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

21.00 SH21 HARDWARE FOR DOORS

21.01 CPWD 9.97.1 Providing and fixing 300x10mm size aluminum tower bolts ISI marked each 66.00 112.10 7,399
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete

21.02 CPWD 9.97.2 Providing and fixing 250x10mm size aluminium tower bolts ISI marked each 106.00 95.25 10,097
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete

21.03 CPWD 9.97.4 Providing and fixing 150x10mm size aluminum tower bolts ISI marked each 850.00 65.35 55,548
DSR 2014 anodised ( anodic coating not less than grade AC10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary screws etc.
complete

21.04 CPWD 9.101.2 Providing and fixing aluminum hanging twin rubber floor door stopper ISI each 570.00 83.95 47,852
DSR 2014 marked anodised (anodic coating not less then grade AC 10 as per IS :1868
) transparent or dyed to required colour or shade with necessary screw etc.
complete

21.05 CPWD 9.113 Providing & fixing bright finished 100mm mortice lock with 6 levers without each 344.00 465.95 160,287
DSR 2014 pair of handles for aluminum door with necessary screws etc. complete (Best
make of approved quality) as per direction of Engineer-in-charge.

21.06 CPWD based 9.83 Providing and fixing rack and pinion non-handed door closer of Dorma TS Each 12.00 7,878.50 94,542
DSR 2014 73V size 2-4, with standard arm and with two independent closing valves and
latching speed adjustable by arm, conforming to EN 1154. The door closer
shall be with open hold open function.

21.07 CPWD based Providing and fixing 300mm long 22mm dia stainless steel pull handles SS 304 pair 4.00 2,884.92 11,540
DSR 2014 9.81.1 grade, back to back with adjustable for fixing to shutter, washers etc. Model
TGDI -D3000 etc. complete.

161
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
21.08 NS AR Providing and fixing 900mm long 38mm dia stainless steel pull handles SS 304 pair 4.00 11,000.00 44,000
grade, back to back with adjustable for fixing to shutter, washers, raised
beveling on the outer surface, etc. Model TGDI -H900 etc. complete.

21.09 CPWD 21.04.1 Providing and fixing double action hydraulic floor spring of approved brand each 16.00 2,039.00 32,624
DSR 2014 and manufacture conforming to IS : 6315, having brand logo embossed on
the body/plate with double spring mechanism and door weight upto 125 kg,
for doors, including cost of cutting floors, embedding in floors as required and
making good the same matching to the existing floor finishing and cover
plates with brass pivot and single piece M.S. sheet outer box with slide plate
etc. complete as per the direction of Engineer-in-charge -With stainless steel
cover plate minimum 1.25 mm thickness

21.10 NS AR Providing and fixing Dorma make floor spring BTS 75V EN 1-4 in doors with top each 4.00 18,770.76 75,083
pivot, bottom pivot and stainless steel cover plate with back check and
adjustable closing speed from 175 deg. As per EN 1154 and CE marked i/c
cutting of glass for patch fittings, cutting and repairing of floor.

21.11 NS AR Providing and fixing Dorma make floor lock SS for glass doors each 4.00 3,500.00 14,000

21.12 NS AR Providing and fixing Sliding door handle with lock each 554.00 373.00 206,642

21.13 NS AR Providing and fixing Sliding door heavy duty roller each 1,108.00 256.48 284,180

21.14 NS AR Providing and fixing Sliding window handle with lock each 832.00 373.00 310,336

21.15 NS AR Providing and fixing casement window handle each 578.00 380.00 219,640

21.16 NS AR Providing and fixing casement Door handle each 32.00 380.00 12,160

21.17 NS AR Providing and fixing Baby latch CP brass as per approved sample. each 211.00 120.00 25,320

21.18 NS AR P/F Magic eye as per approved sample each 60.00 100.00 6,000

Total of Subhead-21 1,617,247

162
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
22.00 SH22 EXTERNAL FAÇADE - GRC SCREENS,ALUMINIUM LOUVERS
22.01 NS AR Providing and Fixing of (Glass Fibre Reinforced Jali)GRC Jalli 50 mm thick of sqm 1,244.03 5,186.00 6,451,540
size, pattern, design, thickness and colour of approved make to be fixed
on/between RCC / Block work Column or structural steel work in vertical with
Dry Fixing method with all appropriate steel frame work , using appropriate
fasteners, and necessary hardware with scaffolding, etc in Building Façade.
The jali shall be made from 53 grade White Portland Cement . Super
Plasticizers, UV Resistant Synthetic inorganic pigments shall be used for
pigmentation. The jali shall be securely fixed with stainless steel bolts and
anchor fasteners(304 grade) of required size at specified locations. The rate
includes the cost of 50 mm thick Jali, SS brackets, anchor fasteners, SS sleeves
labour charges for fixing, required scaffolding etc. for all heights and leads.
The surface area of Jali shall be measured for payment.

Total of Subhead-22 6,451,540


23.00 SH-23 MISCELLANEOUS ITEMS -
23.01 CPWD 5.29.2.1 Providing and fixing Aluminium fluted strips 3.15 mm thick sheet covering metre 178.00 330.05 58,749
DSR 2014 150mm wide over expansion joints with iron screws as per design.

23.02 CPWD 5.44.1 Providing and fixing of expansion joint system upto 100mm width related with metre 41.14 6,358.55 261,591
DSR 2014 floor location as per drawings and direction of Engineer-In-Charge. The joints
system will be of extruded aluminum base members, self aligning / self
centering arrangement and support plates etc. as per ASTM B221-02. The
system shall be such that it provides floor to floor /floor to wall expansion
control system for various vertical location in load application areas that
accommodates multi directional seismic movement without stress to it's
components. System shall consist of metal profiles with a universal aluminum
base member designed to accommodate various project conditions and
finish floor treatments. The cover plate shall be designed of width and
thickness required to satisfy projects movement and loading requirements
and secured to base members by utilizing manufacturer’s pre-engineered
self-centering arrangement that freely rotates / moves in all directions. The
Self – centering arrangement shall exhibit circular sphere ends that lock and
slide inside the corresponding aluminum extrusion cavity to allow freedom of
movement and flexure in all directions including vertical displacement.
Provision of Moisture Barrier Membrane in the Joint System to have watertight
joint is mandatory requirement all as per the manufactures design and as
approved by Engineer -in- Charge . (Material shall confirm to ASTM 6063.)

163
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
23.03 NS AR Supplying, drilling/ cleaning hole and injecting Hilti or equivalent ETA
approved HIT-RE 500 chemical with the help of Hilti HDM 500 dispenser, into a
hole of dia and depth as per manufacture's structural consultant
specifications and fixing rebar's of required diameters subsequently . The
chemical should be have successful usage in wet / water saturated concrete
/ diamond cored holes. The chemical should have approval against creep
and corrosion. Fixing methodology to be followed as per manufacturer
guidelines. Steel will be paid under separate head. Manufacturer to submit
rebar depth calculations basement on design loads and other parameters
as provided by Consultant and in accordance with EOTA - TR -023/029
guidelines for post installed rebar connection for approval.

23.3.1 NS AR 10mm Dia, rebar 150mm depth each 1,717.00 153.98 264,384
23.3.2 NS AR 12mm Dia, rebar 180mm depth each 1,030.00 308.00 317,240
23.3.3 NS AR 16mm Dia, rebar 240mm depth each 172.00 538.95 92,699
23.3.4 NS AR 20mm Dia, rebar 300mm depth each 86.00 1,047.00 90,042
23.3.5 NS AR 25mm Dia, rebar 375mm depth each 34.00 2,301.77 78,260
23.04 NS AR Supplying, drilling/ cleaning hole and fixing Hilti or equivalent make heavy -
duty ETA approved Toque controlled expansion HSL -3-B mechanical anchor
of appropriate size in concrete and fixing plates subsequently. The anchor
should be consist of 8.8 grade bolt with safety cap, washers, distance sleeve,
expansion sleeve, cone and a collapsible plastic section. All steel
components should be galvanised to minimum 5 microns. Red cap should
come out after required setting torque is applied for installation.
manufacturer should submit anchor design report based on design loads
and other parameters as provided by consultant. Metal anchors should be
designed in accordance with ETAG 001 annexure C guidelines for
anchorage of metal anchors for use in concrete. Application at site should
be done as per manufacturer guidelines.

23.4.1 NS AR M12 of standard length each 26.00 785.85 20,432


23.4.2 NS AR M16 of standard length each 26.00 1,468.56 38,183
23.4.3 NS AR M20 of standard length each 20.00 2,499.84 49,997
23.4.4 NS AR M24 of standard length each 26.00 3,294.28 85,651

164
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
23.05 CPWD 5.46.1 Providing and fixing of expansion joint system upto 100mm width of metre 8.70 6,358.55 55,319
DSR 2014 approved make and manufactures for various roof locations as per
approved drawings and direction of Engineer-In-Charge. The joints shall be
of extruded aluminum base members with, self aligning and self centering
arrangement support plates as per ASTM B221-02. The system shall be such
that it provides watertight roof to roof/roof to corner joint cover expansion
control system that is capable of accommodating multidirectional seismic
movement without stress to its components. System shall consist of metal
profile that incorporates a universal aluminum base member designed to
accommodate various project conditions and roof treatments. The cover
plate shall be designed of width and thickness required to satisfy movement
and loading requirements and secured to base members by utilizing
manufacturer’s pre-engineered self-centering arrangement that freely
rotates / moves in all directions. The Self centering arrangement shall exhibit
circular sphere ends that lock and slide inside the corresponding aluminum
extrusion cavity to allow freedom of movement and flexure in all directions
including vertical displacement. The Joint System shall resists damage or
deterioration from the impact of falling ice, exposure to UV, airborne
contaminants and occasional foot traffic from maintenance personnel.
Provision of Moisture Barrier Membrane in the Joint System to have water
tight joint is mandatory requirement. Material shall confirm to ASTM 6063.

23.06 MP PWD 12.18.2 Providing and Fixing of sky lights consisting of Multi cell/tight cell sqm 320.00 3,546.00 1,134,720
SOR 2014 Polycarbonate Panel System of approved colour, 16mm thick (minimum)
having uniform in color with an integral Tight-Cell core constructed not to
exceed 4mm x 4mm in a cross section, Vertical Standing Seam
manufactured at both sides of the panel. Snap-on connector to interlock
the panels shall have a grip-lock double tooth locking mechanism to ensure
maximum uplift capability & shall be of same color as that of panel. Panel
shall be factory sealed/end welded panels with additional End-
cap/Aluminium U-Profile (mill finish) for ends. Panel shall be co-extruded with
special anti glare compound and UV protected. The full system shall be
fitted on MS purlins perpendicular to direction of sheeting with purlin spacing
as specified by Manufacturer.  The weight of the panel only shall not be less
than 3250 gram per square metre.

165
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
The rate includes cost of all the operations, labour & all materials and tests
(as applicable) involved such as bolts nuts and screws etc. and labour for
cutting bending to required profile, necessary scaffolding, hoisting in position
etc. for proper completion of the work etc. complete as per specification
drawings and direction of Engineer in charge . Finished surface area of
roofing fixed over steel tubular structure shall be measured for payment. MS
tabular frame work shall be measured separately for payment )

Total of Subhead-23 2,547,267

166
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2 GRAND SUMMARY OF SANITARY & PLUMBING WORKS I/C STP, PUMPS, EQUIPMENTS,
EXTERNAL SEWERAGE WORKS

S.NO HEAD ESTIMATED


AMOUNT IN INR

INTERNAL PLUMBING WORKS

2.01 Academic & administration Block with basement ( A1,A2,A3,A4) 46,998,104

2.02 Hostel BLOCK H1 & H2 28,496,523

2.03 Residential Type 1 & 2 (BLOCK R3) 16,903,183

2.04 Residential Type 3 &4 (BLOCK R1&R2) 27,001,925

2.05 EXTERNAL PLUMBING WORKS- SEWERAGE & DRAINAGE SYSTEM, DOMESTIC WATER SUPPLY / FLUSHING / GARDEN 42,183,133
HYDRANT LINE

2.06 SEWERAGE TREATMENT PLANT (CAPACITY:185 KLD) 10,454,653

2.07 WATER BODY WITH FOUNTAINS NEAR CRICKET GROUND 2,635,775

GRAND TOTAL I/C ALL TAXES I.E. WORK CONTRACT TAX, SERVICE TAX 174,673,296

167
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATED COST OF ACADEMIC AND ADMINISTRATION BLOCK WITH
BASMENT (A1, A2, A3 & A4)

SUB HEAD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

IA SANITARY INSTALLATIONS (DSR) 913,093

IB SANITARY INSTALLATIONS (NON-DSR) 3,226,380


-
IIA SOIL & WASTE (DSR) 1,995,157

IIB SOIL & WASTE (NON-DSR) 37,498,330


-
IIIA INTERNAL WATER SUPPLY SYSTEM (DSR) 1,703,741

IIIB INTERNAL WATER SUPPLY SYSTEM (NON-DSR) 3,535,407


-
IVA MISCELLANEOUS (DSR) 449,500

IVB MISCELLANEOUS (NON-DSR) 150,080

INTERNAL PLUMBING COST 49,471,688

LESS 5% FOR UPRNN WORKING (2,473,584)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 46,998,104

168
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATE FOR ADMINISTRATIVE AND ACADEMIC BLOCK

Description of item
item code
S.NO. Dept. Unit Quantity Rate Rs. P. Amount Rs.
no.

IA. SANITARY FIXTURES (DSR ITEMS)

CPWD Providing and fixing Stainless Steel A ISI 304 kitchen sink as per IS:13983 with
DSR 2014 C.I. brackets and stainless steel plug & 40mm waste coupling including
1.0 17.10 painting of fittings and brackets, cutting and making good the walls
wherever required.

510x1040 mm bowl depth 200 mm (Kichen sink with drain board)


CPWD
1.1 17.10.1.3
DSR 2014 Each 4.00 5,996.15 23,985
Providing and Fixing C.P. brass Sink mixer of approved quality and make
2.0 18.61 conforming to IS: Specification
MP SOR
15 mm nominal bore
2.1
Each 4.00 1,724.00 6,896
Providing and fixing C.P. brass basin mixer of approved quality and make
3.0 18.59 conforming to IS:specification.
MP SOR
15 mm nominal bore.
3.1
Each 98.00 1,759.00 172,382
4.0 MP SOR 25.37 Providing and fixing in position best indian Health Faucet with 8 mm dia, 1
Meter long Flexible tube & wall bracket with NRV
Each 100.00 1,920.00 192,000

169
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,
200 mm wide with minimum distances of 37 mm from wall face with
CPWD concealed fittings arrangement of approved quality and colour, weighing
5.0 17.72
DSR 2014 not less than 88 gms.

Each 92.00 218.50 20,102


Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth
CPWD 102mm, height of 75mm with concealed fitting arrangements, weighing not
6.0 18.65 less than 106 gms.
DSR 2014
Each 92.00 164.95 15,175
Providing and fixing in position best indian C.P brass made (0.3 micron
7.0 MP SOR 25.60 chrom and 10 micron Nickel plated) Double coat hook
Each 100.00 720.00 72,000
Providing and Fixing 15 mm nominal bore CP Brass bib cock of approved
8.0 18.49 quality conforming to IS: 8931.
CPWD
-
DSR 2014
15 mm nomial bore
8.1 18.49.1 Each 16.00 459.50 7,352
Providing and fixing C.P. brass angle valve for basin mixer and geyser points
9.0 18.53 of approved quality conforming to IS:8931
CPWD
-
DSR 2014
15mm Nominal Bore
9.1 18.53.1 559.00 283,804
Each 507.70
Providing and Fixing C.P. Brass toilet paper holder,
CPWD
10.0 17.34.1
DSR 2014 Each 100.00 415.90 41,590
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of
CPWD approved quality) complete with 6 mm thick hard board ground fixed to
11.0 17.31 wooden cleats with C.P. brass screws and washers complete.
DSR 2014
Each 98.00 793.95 77,807

TOTAL C/O TO SUMMARY


913,093

170
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

IB. SANITARY FIXTURES (NON-DSR ITEMS)

1.0 MR Providing & fixing white vitreous china Wall hung / Extended Wall hung type
European type water closet with C.P. bolts, nuts, C.I. chair or other hanging
arrangement, including solid plastic seat and cover with lid, C.P. brass hinge
rubber buffers, with accessories,C.I/M.S. brackets painted with two coats of
enamel paint of approved shade over a coat of primer. C.P. brass screws
and wooden cleats, including cutting and making good the wall and floors
wherever required.(Make: Hindware "Studio" Cat No: 20061 with Seat cover
and Accessories Or Equivalant) . 846,500
Each 100.00 8,465.00
2.0 MR Providing and Fixing Exposed Flushing Cistern with dual flush, flush-stop
function, noise less float valve and fast filling action with all component parts
of high quality complete including fixing frame and set for Item no. 1.0 (a)
(Make: Hindware Starwhite OR Equivalent )
Each 100.00 2,600.00 260,000
3.0 MR Providing and Fixing White vitreous china flat back wash basin size
450x300mm with C.I. brackets painted white, 32mm dia. C.P. waste, C.P chain
and rubber plug, C.P. cast brass bottle trap with C.P. connecting pipe to wall
and C.P wall flange and rubber adapter for waste connection complete
including cutting and making good the walls wherever required.(Hindware
"Compact" Cat No: 10004 & Bottle Trap: Vijay "ADS” 565 & 522).

Each 98.00 3,495.00 342,510


4.0 MR Providing and Fixing vitreous china flat back urinal of size: 610x410x380 mm
with CP Cast Bottle Trap, C.I. hangers, 15mm dia inlet to built in spreaders
with inbuilt waste with C.P flange, complete including cutting and making
good the walls and floors wherever required. (Make: HINDWARE Cat No:
60002 & Bottle Trap: Vijay "ADS” 565 & 552 OR Equivalent )
Each 55.00 7,885.00 433,675
5.0 MR Providing and Fixing electrical operated concealed automatic flushing
system for urinals, including front S.S plate 125 x 125mm chrome sensor with
CP brass body, ball valve etc,complete in all respect including cutting and
making good the walls wherever required .(Make: UTEC Cat No "UT-11C" OR
Equivalent ) Each 55.00 6,955.00 382,525
-

171
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.0 MR Providing and fixing V.C division plate fixed with expandable anchor
fasteners with C.P. brass bolts and washers embedded in wall with anchor
and set in cement concrete complete, including cutting and making good
the walls wherever required.(Make: HINDWARE Cat No: 61001)

Each 55.00 2,800.00 154,000


7.0 MR Providing and Fixing C.P brass air purifier container, fixed to wooden cleats
with Stainless Steel screws, complete including making good the walls
wherever required. (Make: VIJAY Cat No: 432).
Each 58.00 845.00 49,010
8.0 MR Providing and Fixing CP auto push cock with CP Wall flange for drinking
water purpose complete as per direction of the engineer-in-charge. (Make:
VIJAY Cat no.1065 OR Equivalent ).
Each 10.00 1,865.00 18,650
9.0 MR Providing and Fixing straight / offset type flexible single body push fit type WC
pan connector with factory supplied seal guard with integral Single mould
sealing fins made of flexible EVA body, including bush / adaptor for use with
C.I. Pipe as supplied with the pan connector.(Make: Viega Cat No: 103668
OR Equivalent ).
Each 100.00 1,751.00 175,100
10.0 MR Providing and Fixing in position storage type Hot Water electrical horizontal
heaters with copper container, insulation, and stove enameled M.S. jacket,
thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia
inlet with non return valve and 15/20mm dia outlet including making
connections complete in all respects. (wall mounted with suitable M.S. bolts
and nuts) (Make: VENUS OR Equivalent )
-
MR Capacity 15 liters
10.1 Each 6.00 9,855.00 59,130
MR Capacity 25 liters
10.2 Each 40.00 11,315.00 452,600
MR Capacity 35 liters
10.3 Each 4.00 13,170.00 52,680

TOTAL C/O TO SUMMARY


3,226,380

172
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SOIL, WASTE AND VENT PIPES (DSR ITEMS)
IIA
-
CPWD Providing and Fixing soil, waste and vent Pipes
1.0 DSR 2014 17.35
-
100 mm dia
1.1 17.35.1
-
Centrifugally cast (spun) iron Socket and Spigot S&S pipe as per IS: 3989
1.2 17.35.1.2
Meter 1,200.00 917.75 1,101,300
75 mm Dia
1.3 17.35.2

Centrifugally cast (spun) iron socketed pipe as per IS: 3989


1.4 17.35.2.2
Meter 60.00 791.30 47,478
CPWD Providing and Fixing G.I. Class "B" pipe complete with G.I. Fittings and angle
2.0 DSR 2014 18.10 suports, clamps, including cutting and making good the walls etc.
-
32 mm dia
2.1 18.10.4 Meter 220.00 343.20 75,504
40 mm dia
2.2 18.10.5 Meter 115.00 425.65 48,950
50 mm dia
2.3 18.10.6 Meter 200.00 527.20 105,440
CPWD Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes
DSR 2014 and fittings with two coats of synthetic enamel paint of any colour such as
3.0 17.65 chocolate grey, or buff etc. over a coat of primer (of approved quality) for
new work :
-
100 mm dia Pipe
3.1 17.65.1 Meter 1,200.00 38.65 46,380
75 mm diameter pipe
3.2 17.65.2 Meter 60.00 29.50 1,770

173
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
CPWD Painting of G.I. Pipes and fittings with two coats of anti-corrosive bitumastic
4.0 DSR 2014 18.40 paint of approved quality.
-

4.1 18.40.4 32 mm dia 2,288


Meter 220.00 10.40
4.2 18.40.5 40 mm dia 1,363
Meter 115.00 11.85
4.3 18.40.6 50 mm dia 2,830
Meter 200.00 14.15
CPWD Providing and fixing M.S. holder-bat clamps of approved design to Sand
DSR 2014 Cast iron/cast iron (spun) pipe embedded in and including cement
5.0 17.37 concrete blocks 10X10X10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) including cost of cutting holes
and making good the walls etc. -
For 100mm dia. Pipe
5.1 17.37.1 Each 75.00 152.90 11,468
For 75 mm Dia
5.2 1.37.2 Each 60.00 150.60 9,036
CPWD Providing and fixing bend of required degree with access door, insertion
6.0 DSR 2014 17.38 rubber washer 3mm thick, bolts and nuts complete.
-

6.1 17.38.1 100mm Dia pipe -

6.2 17.38.1.2 Sand cast iron S&S as per IS: 3989 Each 120.00 385.70 46,284
CPWD Providing and fixing plain bend of required degree.
7.0 17.39 -
DSR 2014
100mm
7.1 17.39.1 -
Sand cast iron S&S as per IS: 3989
7.2 17.39.1.2 36,933
Each 110.00 335.75
CPWD Providing and fixing heel rest sanitary bend
8.0 17.40 -
DSR 2014
100 mm dia
8.1 17.40.1 -
Sand cast iron S&S as per IS: 3989
8.2 17.40.1.2 Each 120.00 371.75 44,610

174
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
CPWD Providing and fixing single equal plain junction of required degree with
9.0 DSR 2014 17.43 access door, insertion rubber washer 3mm thick, bolts and nuts complete.
-

9.1 17.43.1 100x100x100mm


-

9.2 17.43.1.2 Sand cast iron S&S as per IS: 3989 Each 80.00 623.80 49,904
CPWD Providing and fixing double equal plain junction of required degree.
10.0 17.42 -
DSR 2014
100x100x100x100 mm
10.1 17.42.1 -
Sand cast iron S&S as per IS: 3989
10.2 17.42.1.2 63,589
Each 85.00 748.10
CPWD Providing and Fixing Terminal guard
11.0 17.56 -
DSR 2014
100 mm
11.1 17.56.1 -
Sand cast iron S&S as per IS: 3989
11.2 17.56.1.2 Each 90.00 434.50 39,105
CPWD Providing and Fixing collar: -
12.0 17.57 -
DSR 2014
100 mm
12.1 17.57.1 -
Sand cast iron S&S as per IS: 3989
12.2 17.57.1.2 Each 110.00 318.35 35,019
CPWD Providing and fixing door piece, insertion rubber washer 3mm thick, bolts &
13 DSR 2014 17.55 nuts complete :
-

13.1 17.55.1 100 mm


-

13.2 17.55.1.2 Sand cast iron S&S as per IS: 3989 Each 75.00 513.45 38,509
CPWD Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally
14.0 DSR 2014 17.59 cast (spun) iron pipes of diameter:
-
100mm
14.1 17.59.1 8,232
Each 120.00 68.60
-

175
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
CPWD Providing and Fixing trap of self cleansing design with screwed down or
DSR 2014 hinged grating with or without vent arm complete, including cost of cutting
15.0 17.60
and making good the walls and floors.
-
100 mm inlet and 100 mm outlet
15.1 17.60.1
-
Sand cast iron S&S as per IS: 3989
15.2 17.60.1.1 Each 135.00 982.55 132,644
CPWD Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron
16.0 DSR 2014 17.58 pipes and fittings of diameter : -
100 mm diameter pipe
16.1 17.58.1 31,688
Meter 130.00 243.75
16.2 17.58.2 75 mm diameter pipe
Meter 65.00 205.30 13,345
Making Khurras 45 x 45 cm with average minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20
CPWD mm nominal size) over P.V.C sheet 1 m x 1 m x 400 micron, finished with 12
17.0 12.22
DSR 2014 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
cement rounding the edge and making and finishing the outlet complete.
Each 8.00 186.45 1,492
-
Total C/O to Summary
1,995,157

SOIL, WASTE AND VENT PIPES (DSR ITEMS)


IIB -
1.0 MR Providing and Fixing Floor drain by fixing G.I. Reducing elbow of 100 x 50 mm
in cement concrete 1:2:4 at all levels (exlcuding cost of grating) for
connection to floor traps in sunken portions, complete as per required slope
as per drawings and as per approval of the engineer-in-charge.
Each 51.00 730.00 37,230
2.0 MR Providing & laying cement concrete 1:2:4 mix (1 cement : 2 coarse sand: 4
stone aggregate 20mm and down gauge) 75mm in bed and pipe. For 150,
100mm, 75mm and 50mm dia pipes under floor including centering &
shuttering wherever required.

Metre 780.00 160.00 124,800

176
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.0 MR Providing and Fixing CP Grating with frame and SS Screws casted heavy duty
125 mm dia including cutting and making good the walls and floors
wherever required complete in all respects (Make: Vijay Cat No: 1262).
Each 185.00 645.00 119,325
4.0 Providing and fixing UPVC pipes of 10 kg./cm2 conforming to IS: 4985
including all fittings with or without access door or without access i.e bends,
junctions, cowls, offsets, etc., and jointing with solvent cement and
excavation, refilling and disposal of surplus earth, including cutting holes in
walls and floors, excavation, refilling and disposal of surplus earth wherever
required and making good the same, complete as directed by the Engineer-
in-Charge. -

7.1 MR 75mm outer dia. 165.00 55,275


Metre 335.00
7.2 MR 90mm outer dia. 50.00 22,000
Metre 440.00
7.3 MR 160mm outer dia. 300.00 372,000
Metre 1,240.00
7.4 MR 200mm outer dia. 150.00 293,250
Metre 1,955.00
2
8.0 MR Providing and fixing UPVC pipes of 6 kg./cm conforming to IS: 4985
including all fittings with or without access door or without access i.e bends,
junctions, cowls, offsets, etc., and jointing with solvent cement and
excavation, refilling and disposal of surplus earth, including cutting holes in
walls and floors, excavation, refilling and disposal of surplus earth wherever
required and making good the same, complete as directed by the Engineer-
in-Charge. -

8.1 MR 75mm outer dia. 20.00 7,900


Metre 395.00
8.2 MR 90mm outer dia. Metre 10.00 305.00 3,050

10.0 MR Providing and fixing pre-fab polymer concrete channels conforming to


relevant EN standards with V-shaped profile, tounge and groove jointing
arrangement, in-built ductile iron edge rail, with in-built slope along the
complete length of the channel, and polymer concrete channels to be
made of zero water absorbtion, of density being 2.1 - 2.3gm/cm3, with
surface roughness of aprox 25 μm, complete including all necessary civil and
finishing works as required as per site and the instructions of the engineer - in -
charge, (Make: ACO or approved equivalent) for following sizes:Size 350 x
385 mm (B x H) Metre 925.00 39,420.00 36,463,500
-
Total C/O to Summary
37,498,330

177
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
INTERNAL WATER SUPPLY (NON-DSR ITEMS)
III B -
1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply, including all CPVC plain & brass
threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This
CPWD
18.8 includes jointing of pipes & fittings with one step CPVC solvent cement and
DSR 2014
the cost of cutting chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.
-
Concealed work, including cutting chases and making good the walls etc.
-

1.1 18.8.1 15mm dia 270.00 275,400


Metre 1,020.00
1.2 18.8.2 20 mm dia 296.40 231,192
Metre 780.00
1.3 18.8.3 25 mm dia 351.30 12,296
Metre 35.00
1.4 18.8.4 32 mm dia 4,224
Metre 10.00 422.40
-
Providing and fixing G.I. class 'B' pipes complete with G.I. fittings, angle
CPWD suports and clamps, i/c cutting and making good the walls etc. exposed on
2.0 18.10
DSR 2014 walls. -
15mm dia
2.1 18.10.1 Metre 20.00 215.10 4,302
20 mm dia
2.2 18.10.2 Metre 500.00 249.30 124,650
25 mm dia
2.3 18.10.3 Metre 410.00 304.15 124,702
32 mm dia
2.4 18.10.4 Metre 280.00 343.20 96,096
40 mm dia
2.5 18.10.5 Metre 170.00 425.65 72,361
50 mm dia
2.6 18.10.6 Metre 220.00 527.20 115,984
65 mm dia
2.7 Derived Metre 310.00 610.95 189,395
80 mm dia
2.8 Derived Metre 165.00 709.80 117,117
100 mm dia
2.9 Derived Metre 120.00 827.75 99,330

178
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Painting G.I. pipes and fittings with synthetic enamel white paint with two
CPWD
3.0 18.38 coats over a ready mixed priming coat, both of approved quality for new
DSR 2014 -
work.
3.1 18.38.1 15 mm dia. nominal bore Metre 9.60 192
20.00
3.2 18.38.2 20 mm dia. nominal bore Metre 11.35 5,675
500.00
3.3 18.38.3 25 mm diameter pipe. Metre 14.95 6,130
410.00
3.4 18.38.4 32 mm diameter pipe. Metre 17.70 4,956
280.00
3.5 18.38.5 40 mm diameter pipe. Metre 21.00 3,570
170.00
3.6 18.38.6 50 mm diameter pipe Metre 24.75 5,445
220.00
3.7 Derived 65mm dia. nominal bore Metre 28.50 8,835
310.00
3.8 Derived 80mm dia. nominal bore Metre 32.25 5,321
165.00
3.9 Derived 100mm dia. nominal bore Metre 36.00 4,320
120.00
-
Providing and fixing G.I. Union heavy class in G.I. Pipe including cutting and
CPWD
4.0 18.46 threading the pipe and making long screws etc. complete (new work)
DSR 2014 -
4.1 18.46.1 15mm dia nominal bore Each 2.00 165.25 331
4.2 18.46.2 20mm dia nominal bore Each 50.00 188.50 9,425
4.3 18.46.3 25 mm nominal bore Each 41.00 200.10 8,204
4.4 18.46.4 32 mm nominal bore Each 28.00 240.75 6,741
4.5 18.46.5 40 mm nominal bore Each 17.00 316.25 5,376
4.6 18.46.6 50 mm nominal bore Each 22.00 392.40 8,633
4.7 18.46.7 65mm dia. nominal bore Each 31.00 636.30 19,725
4.8 18.46.8 80mm dia. nominal bore Each 16.50 729.25 12,033

4.9 Derived 100mm dia. nominal bore Each 12.00 822.20 9,866
Providing and fixing ball valve (brass) of approved quality, High or low
5.0 18.18 pressure, with plastic floats complete :

5.1 18.18.1 15 mm nominal bore Each 28.00 288.50 8,078


5.2 18.18.2 20 mm nominal bore. Each 103.00 409.90 42,220
5.3 18.18.3 25 mm nominal bore Each 33.00 449.95 14,848

179
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6 MP SOR 8.6 Providing & Fixing following Cast iron Butterfly Valves including jointing &
testing with cost of jointing of materials like Bolts, nuts and rubber insertion all
complete as per IS : 13095 :1991(class PN 1.6)

6.1 8.6.2 65 mm nominal bore


Each 17.00 1,986.00 33,762
6.2 8.6.3 80 mm nominal bore
Each 6.00 2,168.00 13,008

TOTAL C/O TO SUMMARY


1,703,741

III B WATER SUPPLY (NON-DSR ITEMS) -


Insulation for Internal Works -
MR Providing and fixing thermal insulation over hot water pipes in chase having
Red Oxide Primer Coat with 6mm thick 'Kaiflex' /Careflex or approved
equivalent thermal insulation tubing, a elastomeric flexible material having
hermetic blister closed cell structure of expanded synthetic rubber having
1.0 density of 60-90 Kg/m3 over pipes of following sizes including all required
accessories complete as per Manufactuer's specifications and finishing it as
per site requirement with Cement Plaster of 1:3 (1 Cement: 3 Coarse sand).
-
1.1 For 15mm Dia or Equivalent Metre 165.00 295.00 48,675
1.2 For 20mm Dia or Equivalent Metre 165.00 330.00 54,450
2.0 Providing and fixing forged brass lever operated flow control ball valve of full
flow with forged brass ball (Machined to mirror smooth finish with hard
chrome plated) and spindle with setting and gland of superior quality having
minimum working pressure of 10 kg/cm2 etc. complete in all respect.
-
2.1 MR 32 mm nominal bore. Each 8.00 1,555.00 12,440
2.2. MR 40 mm nominal bore Each 4.00 2,265.00 9,060
2.3 MR 50 mm nominal bore Each 1.00 3,300.00 3,300
-
Total C/O to Summary 3,535,407

180
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
MISCELLANEOUS (DSR)
IV A
Providing and placing on terrace (at all floor levels) polyethylene water
storage tank, ISI : 12701 marked, with cover and suitable locking
CPWD
1.0 18.48 arrangement and making necessary holes for inlet, outlet and overflow pipes
DSR 2014 but without fittings and the base support for tank.
liters 7.25 62,000.00 449,500

TOTAL C/O TO SUMMARY 449,500

MISCELLANEOUS (NON-DSR)
IVB
Providing and fixing insect-proof coupling to vent pipes of overhead tank
with threaded or flanged joints, including G.I. flanges, nuts, bolts, 3mm thick
1.0
rubber insertions complete.
-
1.1 MR 50mm dia Each 2.00 870.00 1,740
1.2 MR 65mm dia Each 2.00 1,000.00 2,000
MR Providing & fixing M.S. structural work fabricated from standard section e.g.
M.S rounds, angles, channels, plates including cutting to size,drilling,welding
fixing and welding to insert plates in RCC structural members as directed by
2 engineer-in-charge including cutting and making good the walls, ceilings
and floors. (As per the Instructions of the Engineer-In-Charge)
Kg 1,200.00 70.00 84,000
MR Providing and fixing heavy duty Gunmetal float valve including all required
3 accessories complete in all respect as per direction of the engineer -in-
charge . -
3.1 50 mm dia Each 2.00 5,580.00 11,160
3.2 65 mm dia Each 3.00 6,190.00 18,570
MR Providing and fixing in position enclosed type water meter (bulk type)
confirming to IS : 2373 including all necessary connecting accessories, T&P,
4
labour and materials complete in all respects.
-

4.1 50 mm dia 1.00 14,190


Each 14,190.00
4.2 65 mm dia 1.00 18,420
Each 18,420.00

181
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
TOTAL C/O TO SUMMARY
150,080

ESTIMATED COST OF HOSTEL BLOCK (H1 & H2)

SUB HEAD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

IA SANITARY INSTALLATIONS (DSR) 2,157,996

IB SANITARY INSTALLATIONS (NON-DSR) 8,525,091


-
IIA SOIL & WASTE (DSR) 5,666,661

IIB SOIL & WASTE (NON-DSR) 9,543,270


-
IIIA INTERNAL WATER SUPPLY SYSTEM (DSR) 2,849,437

IIIB INTERNAL WATER SUPPLY SYSTEM (NON-DSR) 767,430


-
IVA MISCELLANEOUS (DSR) 362,500

IVB MISCELLANEOUS (NON-DSR) 123,955

INTERNAL PLUMBING COST 29,996,340

LESS 5% FOR UPRNN WORKING (1,499,817)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 28,496,523

182
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATE FOR HOSTEL BLOCK

item code Description of item


S.NO. Dept. Unit Quantity Rate Rs. P. Amount Rs.
no.

IA. SANITARY FIXTURES (DSR ITEMS)

Providing and fixing Stainless Steel A ISI 304 kitchen sink as per IS:13983 with
C.I. brackets and stainless steel plug & 40mm waste coupling including
1.0 17.10 painting of fittings and brackets, cutting and making good the walls
CPWD
wherever required.
DSR 2014
510x1040 mm bowl depth 200 mm (Kichen sink with drain board)
1.1 17.10.1.3
Each 42.00 5,996.15 251,838
Providing and Fixing C.P. brass Sink mixer of approved quality and make
2.0 18.61 conforming to IS: Specification
MP SOR -
15 mm nominal bore
2.1 72,408
Each 42.00 1,724.00
Providing and fixing C.P. brass basin mixer of approved quality and make
3.0 18.59 conforming to IS:specification.
MP SOR -

3.1 15 mm nominal bore.


Each 190.00 1,759.00 334,210
Providing and fixing in position best indian Health Faucet with 8 mm dia, 1
4.0 MP SOR 25.37 Meter long Flexible tube & wall bracket with NRV
Each 190.00 1,920.00 364,800
Providing and fixing PTMT towel rail complete with brackets fixed to wooden
cleats with CP brass screws with concealed fittings arrangement of approved
5.0 17.73
CPWD quality and colour.
-
DSR 2014
600 mm long towel rail with total length of 645 mm, width 78 mm and
5.1 17.73.2 effective height of 88 mm, weighing not less than 190 gms
Each 158.00 541.50 85,557

183
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm
CPWD wide with minimum distances of 37 mm from wall face with concealed fittings
6.0 17.72 arrangement of approved quality and colour, weighing not less than 88 gms.
DSR 2014
Each 190.00 218.50 41,515
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth
CPWD 102mm, height of 75mm with concealed fitting arrangements, weighing not
7.0 18.65
DSR 2014 less than 106 gms.
Each 190.00 164.95 31,341
Providing and fixing in position best indian C.P brass made (0.3 micron
8.0 MP SOR 25.60 chrom and 10 micron Nickel plated) Double coat hook
Each 190.00 720.00 136,800
Providing and Fixing 15 mm nominal bore CP Brass bib cock of approved
9.0 18.49 quality conforming to IS: 8931.
CPWD
-
DSR 2014
15 mm nomial bore
9.1 18.49.1 33.00 15,164
Each 459.50
Providing and fixing C.P. brass angle valve for basin mixer and geyser points
10.0 18.53 of approved quality conforming to IS:8931
CPWD
-
DSR 2014
15mm Nominal Bore
10.1 18.53.1 1,224.00 621,425
Each 507.70
CPWD Providing and Fixing C.P. Brass toilet paper holder,
11.0 17.34.1
DSR 2014 Each 190.00 415.90 79,021
Providing and fixing mirror of superior glass (of approved quality) and of
required shape and size with plastic moulded frame of approved make and
12.0 17.32 shade with 6 mm thick hard board backing :
CPWD
DSR 2014 -
Rectangular shape 1500x450 mm
12.1 17.32.4 93.00 123,918
Each 1,332.45
-
TOTAL C/O TO SUMMARY
2,157,996
-

184
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SANITARY FIXTURES (NON-DSR ITEMS)
IB. -
-
Providing & fixing white vitreous china Wall hung / Extended Wall hung type
European type water closet with C.P. bolts, nuts, C.I. chair or other hanging
arrangement, including solid plastic seat and cover with lid, C.P. brass hinge
rubber buffers, with accessories,C.I/M.S. brackets painted with two coats of
1.0 MR enamel paint of approved shade over a coat of primer. C.P. brass screws
and wooden cleats, including cutting and making good the wall and floors
wherever required.(Make: Hindware "Studio" Cat No: 20061 with Seat cover
and Accessories Or Equivalant) . 190.00 1,608,350
Each 8,465.00
Providing and Fixing Exposed Flushing Cistern with dual flush, flush-stop
function, noise less float valve and fast filling action with all component parts
2.0 MR of high quality complete including fixing frame and set for Item no. 1.0 (a)
(Make: Hindware Starwhite OR Equivalent )
Each 190.00 2,600.00 494,000
Providing and Fixing white vitreous china Oval wash basin size 560x410 mm
for under counter mounting, specially fabricated brackets painted white,
32mm C.P.cast brass bottle trap and connection pipe to wall with C.P. wall
3.0 MR flange and rubber adopter for waste connection complete, including
cutting and making good the walls wherever required.(Hindware Cat
No:10017 & Bottle Trap: Vijay "ADS” 565 & 522 OR Equivalent ))
Each 193.00 4,895.00 944,735
Providing and Fixing 4 way concealed divertor with built-in non-return valve
4.0 MR with diverter handle . (Make: JAQUAR Cat No. CON-421)
Each 158.00 3,460.00 546,680
Providing and Fixing Over head shower 100 mm dia with Shower Arm
5.0 MR complete as per instructions of the engineer-in-charge (Make: JAQUAR OHS-
1719 & SHA-CHR-477P). or as per equivalent make .
Each 158.00 4,505.00 711,790
Providing and Fixing CP Bath spout with wall flange complete as per
instructions of the engineer-in-charge or as per equivalent make .(Make:
6.0 MR
JAQUAR Cat No. SPJ-429)
Each 158.00 4,505.00 711,790
Proving & fixing 15mm dia CP concealed stop cocks. (Make: JAQUAR Cat
7.0 MR No. CON-083)
Each 316.00 1,850.00 584,600
-

185
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and Fixing C.P brass air purifier container, fixed to wooden cleats
8.0 MR with Stainless Steel screws, complete including making good the walls
wherever required (Make: VIJAY Cat No: 432).
Each 190.00 845.00 160,550
Providing and Fixing CP auto push cock with CP Wall flange for drinking
water purpose complete as per direction of the engineer-in-charge (Make:
9.0 MR
VIJAY Cat no.1065 OR Equivalent ).
Each 11.00 1,865.00 20,515
Providing and Fixing straight / offset type flexible single body push fit type WC
pan connector with factory supplied seal guard with integral Single mould
sealing fins made of flexible EVA body, including bush / adaptor for use with
10.0 MR
C.I. Pipe as supplied with the pan connector (Make: Viega Cat No: 103668
OR Equivalent ).
Each 190.00 1,751.00 332,691
Providing and Fixing in position storage type Hot Water electrical horizontal
heaters with copper container, insulation, and stove enameled M.S. jacket,
thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia
11.0 inlet with non return valve and 15/20mm dia outlet including making
connections complete in all respects. (wall mounted with suitable M.S. bolts
and nuts) (Make: VENUS OR Equivalent )
-
Capacity 15 liters
11.1 MR Each 32.00 9,855.00 315,360
Capacity 35 liters
11.2 MR Each 159.00 13,170.00 2,094,030
-
TOTAL C/O TO SUMMARY 8,525,091
-
IIA SOIL, WASTE AND VENT PIPES (DSR ITEMS) -
-
CPWD Providing and Fixing soil, waste and vent Pipes
1.0 17.35 -
DSR 2014
100 mm dia
1.1 17.35.1 -
Centrifugally cast (spun) iron Socket and Spigot S&S pipe as per IS: 3989
1.2 17.35.1.2 Meter 3,170.00 917.75 2,909,268
75 mm Dia
1.3 17.35.2 -
Centrifugally cast (spun) iron socketed pipe as per IS: 3989
1.4 17.35.2.2 Meter 855.00 791.30 676,562

186
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
CPWD Providing and Fixing G.I. Class "B" pipe complete with G.I. Fittings and angle
2.0 DSR 2014 18.10 suports, clamps, including cutting and making good the walls etc.
-
32 mm dia
2.1 18.10.4 Meter 650.00 343.20 223,080
40 mm dia
2.2 18.10.5 Meter 130.00 425.65 55,335
50 mm dia
2.3 18.10.6 Meter 470.00 527.20 247,784
CPWD Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes
DSR 2014 and fittings with two coats of synthetic enamel paint of any colour such as
3.0 17.65
chocolate grey, or buff etc. over a coat of primer (of approved quality) for
new work : -
100 mm dia Pipe
3.1 17.65.1 Meter 3,170.00 38.65 122,521
75 mm diameter pipe
3.2 17.65.2 Meter 855.00 29.50 25,223
CPWD Painting of G.I. Pipes and fittings with two coats of anti-corrosive bitumastic
4.0 DSR 2014 18.40 paint of approved quality.
-
4.1 18.40.4 32 mm dia Meter 450.00 10.40 4,680
4.2 18.40.5 40 mm dia Meter 115.00 11.85 1,363
4.3 18.40.6 50 mm dia Meter 440.00 14.15 6,226
CPWD Providing and fixing M.S. holder-bat clamps of approved design to Sand
DSR 2014 Cast iron/cast iron (spun) pipe embedded in and including cement
5.0 17.37 concrete blocks 10X10X10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) including cost of cutting holes
and making good the walls etc. -

5.1 17.37.1 For 100mm dia. Pipe 172.00 26,299


Each 152.90
5.2 1.37.2 For 75 mm Dia 80.00 12,048
Each 150.60
-
CPWD Providing and fixing bend of required degree with access door, insertion
6.0 DSR 2014 17.38 rubber washer 3mm thick, bolts and nuts complete.
-
100mm Dia pipe
6.1 17.38.1 -
Sand cast iron S&S as per IS: 3989
6.2 17.38.1.2 379.00 146,180
Each 385.70

187
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
CPWD Providing and fixing plain bend of required degree.
7.0 17.39 -
DSR 2014
100mm
7.1 17.39.1 -
Sand cast iron S&S as per IS: 3989
7.2 17.39.1.2 379.00 127,249
Each 335.75
CPWD Providing and fixing heel rest sanitary bend
8.0 17.40 -
DSR 2014
100 mm dia
8.1 17.40.1 -
Sand cast iron S&S as per IS: 3989
8.2 17.40.1.2 30.00 11,153
Each 371.75
CPWD Providing and fixing single equal plain junction of required degree with
9.0 DSR 2014 17.43 access door, insertion rubber washer 3mm thick, bolts and nuts complete.
-

9.1 17.43.1 100x100x100mm


-

9.2 17.43.1.2 Sand cast iron S&S as per IS: 3989 Each 115.00 623.80 71,737

10.0 CPWD 17.56 Providing and Fixing Terminal guard


-
DSR 2014
10.1 17.56.1 100 mm
-

10.2 17.56.1.2 Sand cast iron S&S as per IS: 3989 Each 30.00 434.50 13,035

11.0 CPWD 17.57 Providing and Fixing collar: -


-
DSR 2014
11.1 17.57.1 100 mm
-

11.2 17.57.1.2 Sand cast iron S&S as per IS: 3989 Each 340.00 318.35 108,239
-
CPWD Providing and fixing door piece, insertion rubber washer 3mm thick, bolts &
12 DSR 2014 17.55 nuts complete :
-
12.1 17.55.1 100 mm -
Sand cast iron S&S as per IS: 3989
12.2 17.55.1.2 Each 310.00 513.45 159,170
CPWD Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally
13.0 DSR 2014 17.59 cast (spun) iron pipes of diameter:
-

188
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
100mm
13.1 17.59.1 Each 30.00 68.60 2,058
CPWD Providing and Fixing trap of self cleansing design with screwed down or
DSR 2014 hinged grating with or without vent arm complete, including cost of cutting
14.0 17.60
and making good the walls and floors.
-
100 mm inlet and 100 mm outlet
14.12 17.60.1 -
Sand cast iron S&S as per IS: 3989
14.2 17.60.1.1 235.00 230,899
Each 982.55
CPWD Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron
DSR 2014 pipes and fittings of diameter :
15.0 17.58
-
100 mm diameter pipe
15.1 17.58.1
Meter 1,800.00 243.75 438,750
75 mm diameter pipe
15.2 17.58.2
Meter 150.00 205.30 30,795
Making Khurras 45 x 45 cm with average minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20
mm nominal size) over P.V.C sheet 1 m x 1 m x 400 micron, finished with 12
CPWD
16.0 12.22 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
DSR 2014
cement rounding the edge and making and finishing the outlet complete.

Each 14.00 186.45 2,610


Making Khurras 30 x 30 cm with average minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20
CPWD mm nominal size) over P.V.C sheet 1 m x 1 m x 400 micron, finished with 12
17.0 Derived mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
DSR 2014
cement rounding the edge and making and finishing the outlet complete.

Each 120.00 120.00 14,400


-
Total C/O to Summary
5,666,661

189
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SOIL, WASTE AND VENT PIPES (NON-DSR ITEMS)
IIB -
-
Providing and fixing centrifugally cast (spun) iron soil, waste and vent pipes
as per IS:3989 including all fittings with or without access door of any degree
i.e bends, junctions, cowls, offsets, access pieces, G.I. holder bats and
clamps, stays, etc and jointing with refined pig lead / approved type
1.0 MR sealant compound (dripseal) joints including painting with two coats of
synthetic enamel paint of approved quality & cutting holes in walls and
floors, excavation, refilling and disposal of surplus earth wherever required
and making good the same complete, as directed by the Engineer-in-
charge.150 mm Dia 210.00 555,450
Meter 2,645.00
Providing and laying cement concrete 1:2:4 mix (1 cement :2 coarse sand 4
stone aggregate 20 mm and downgauge) 75 mm thick in bed and
2.0 MR
alround soil and waste pipe under floor of size.100 mm dia
Each 1,250.00 160.00 200,000
Providing and Fixing Floor drain by fixing G.I. Reducing elbow of 100 x 50 mm
in cement concrete 1:2:4 at all levels (exlcuding cost of grating) for
3.0 MR connection to floor traps in sunken portions, complete as per required slope
as per drawings and as per approval of the engineer-in-charge.
Each 185.00 730.00 135,050
Providing and fixing G.I. Inlet fitting with maximum 3 inlets 32,40 & 50 mm size
fabricated from 100 mm dia G.I.pipes and welded G.I. sockets as per site
4.0 MR locations, fixed to C.I. Trap and set in cement concrete as per drawing
complete as per approval of the engineer-in-charge.
Each 235.00 890.00 209,150
Providing and Fixing CP Grating with frame and SS Screws casted heavy duty
125 mm dia including cutting and making good the walls and floors
5.0 MR
wherever required complete in all respects (Make: Vijay Cat No: 1262).
Each 415.00 645.00 267,675
Providing & fixing cast brass clean out plug (FCO & COP) with suitable insert
keys for opening, male threaded joint with G.I. socket caulked to soil
6.0 MR pipe/waste pipe of C.I. and C.I. (LA) pipe as required. (Both for floor & along
ceiling level) -
100mm dia (Brass)
6.1 137.00 137,000
Each 1,000.00
6.2 150mm dia (M.S. / G.I.)
Each 10.00 1,520.00 15,200

190
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing 125mm dia Bronze Chrome plated ring and Grating with
2 stainless steel screws, ring to be embedded in floor with sealant. (Vijay
7 MR Make Cat No : 1262)

Each 441.00 645.00 284,445


8 Providing and fixing pre-fab polymer concrete channels conforming to
relevant EN standards with V-shaped profile, tounge and groove jointing
arrangement, in-built ductile iron edge rail, with in-built slope along the
complete length of the channel, and polymer concrete channels to be
made of zero water absorbtion, of density being 2.1 - 2.3gm/cm3, with
MR
surface roughness of aprox 25 μm, complete including all necessary civil and
finishing works as required as per site and the instructions of the engineer - in -
charge, (Make: ACO or approved equivalent) for following sizes:Size 350 x
385 mm (B x H)
Metre 170.00 39,420.00 6,701,400
2
Providing and laying UPVC pipes (I.S:4985) of 10kg./cm including all
fittings with or without access door i.e bends, junctions, cowls, offsets, etc.,
and jointing with solvent cement and excavation, refilling and disposal of
surplus earth, including cutting holes in walls and floors, excavation, refilling
9.0
and disposal of surplus earth wherever required and making good the
same, complete as directed by the Engineer-in-Charge.

-
75mm outer dia.
9.1 MR Metre 550.00 335.00 184,250
110mm outer dia.
9.2 MR Metre 760.00 625.00 475,000
160mm outer dia.
9.3 MR Metre 195.00 1,240.00 241,800
200mm outer dia.
9.4 MR Metre 70.00 1,955.00 136,850

Total C/O to Summary


9,543,270

191
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
WATER SUPPLY (DSR ITEMS) (INTERNAL AND EXTERNAL)
III A -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply, including all CPVC plain & brass
threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This
CPWD includes jointing of pipes & fittings with one step CPVC solvent cement and
1.0 18.8
DSR 2014 the cost of cutting chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.
-
Concealed work, including cutting chases and making good the walls etc.
-

1.1 18.8.1 15 mm nominal outer dia Pipes


Metre 2,700.00 270.00 729,000
20 mm nominal outer dia Pipes
1.2 18.8.2 Metre 2,115.00 296.40 626,886

1.3 18.8.3 25 mm nominal outer dia Pipes


Metre 115.00 351.30 40,400
Providing and fixing G.I. class 'B' pipes complete with G.I. fittings, angle
CPWD suports and clamps, i/c cutting and making good the walls etc. exposed on
2.0 18.10
DSR 2014 wall. -
15 mm dia. nominal bore
2.1 18.10.1 Metre 65.00 215.10 13,982
20 mm dia. nominal bore
2.2 18.10.2 Metre 240.00 249.30 59,832
25 mm dia. nominal bore
2.3 18.10.3 Metre 290.00 304.15 88,204
32 mm dia. nominal bore
2.4 18.10.4 Metre 335.00 343.20 114,972
40 mm dia. nominal bore
2.5 18.10.5 Metre 440.00 425.65 187,286
50 mm dia. nominal bore
2.6 18.10.6 Metre 360.00 527.20 189,792
65 mm dia. nominal bore
2.7 Derived Metre 600.00 610.95 366,570
80 mm dia. nominal bore
2.8 Derived Metre 100.00 709.80 70,980
100 mm dia. nominal bore
2.9 Derived Metre 10.00 827.75 8,278

192
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Painting G.I. pipes and fittings with synthetic enamel white paint with two
CPWD coats over a ready mixed priming coat, both of approved quality for new
3.0 18.38
DSR 2014 work -

3.1 18.38.1 15 mm dia. nominal bore Metre 65.00 9.60 624

3.2 18.38.2 20 mm dia. nominal bore Metre 240.00 11.35 2,724

3.3 18.38.3 25 mm diameter pipe. Metre 290.00 14.95 4,336

3.4 18.38.4 32 mm diameter pipe. Metre 335.00 17.70 5,930

3.5 18.38.5 40 mm diameter pipe. Metre 440.00 21.00 9,240

3.6 18.38.6 50 mm diameter pipe Metre 360.00 24.75 8,910

3.7 Derived 65mm dia. nominal bore Metre 600.00 28.50 17,100

3.8 Derived 80mm dia. nominal bore Metre 100.00 32.25 3,225

3.9 Derived 100mm dia. nominal bore Metre 10.00 36.00 360
Providing and fixing G.I. Union heavy class in G.I. Pipe including cutting and
CPWD threading the pipe and making long screws etc. complete (new work)
4.0 18.46
DSR 2014
-

4.1 18.46.1 15mm dia nominal bore


Each 1.00 165.25 165

4.2 18.46.2 20mm dia nominal bore


Each 14.00 188.50 2,639

4.3 18.46.3 25 mm nominal bore


Each 18.00 200.10 3,602

4.4 18.46.4 32 mm nominal bore


Each 29.00 240.75 6,982

4.5 18.46.5 40 mm nominal bore


Each 38.00 316.25 12,018

4.6 18.46.6 50 mm nominal bore


Each 33.00 392.40 12,949

4.7 18.46.7 65mm dia. nominal bore


Each 55.00 636.30 34,997

4.8 18.46.8 80mm dia. nominal bore


Each 9.00 729.25 6,563

4.9 Derived 100mm dia. nominal bore


Each 2.00 822.20 1,644

193
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing ball valve (brass) of approved quality, High or low
CPWD pressure, with plastic floats complete :
5.0 18.18
DSR 2014
-

5.1 18.18.1 15 mm nominal bore


Each 33.00 288.50 9,521

5.2 18.18.2 20 mm nominal bore.


Each 238.00 409.90 97,556

5.3 18.18.3 25 mm nominal bore


Each 174.00 449.95 78,291
6 8.6 Providing & Fixing following Cast iron Butterfly Valves including jointing &
testing with cost of jointing of materials like Bolts, nuts and rubber insertion all
MP SOR complete as per IS : 13095 :1991(class PN 1.6)
-
6.1 8.6.2 65 mm nominal bore
Each 12.00 1,986.00 23,832
6.2 8.6.3 80 mm nominal bore
Each 2.00 2,168.00 4,336
6.3 8.6.4 100 mm nominal bore
Each 2.00 2,857.00 5,714
-
TOTAL C/O TO SUMMARY
2,849,437
-
WATER SUPPLY (NON-DSR ITEMS)
III B -
Insulation for Internal Works
1
-
Providing and fixing thermal insulation over hot water pipes in chase having
Red Oxide Primer Coat with 6mm thick 'Kaiflex' /Careflex or approved
equivalent thermal insulation tubing, a elastomeric flexible material having
hermetic blister closed cell structure of expanded synthetic rubber having
density of 60-90 Kg/m3 over pipes of following sizes including all required
accessories complete as per Manufactuer's specifications and finishing it as
per site requirement with Cement Plaster of 1:3 (1 Cement: 3 Coarse sand).

-
For 15mm Dia
1.1 MR 580.00 171,100
Metre 295.00
For 20mm Dia
1.2 MR 1,120.00 369,600
Metre 330.00

194
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs. -
Insulation for External Works
2
-
Providing and fixing insulation for hot water pipe line with fibre glass wool
blankets/mats of 50mm thickness including cleaning of pipes, wrapping of
mats around the pipe with 50mm overlap on all the sides and sealing the
joints with POP tape, stitching 24 SWG x 20mm G.I wire mesh netting over
the mat & cladding 28 gauge aluminum sheets cladding with 25mm overlap
and fixing with self tapping recessed screws, complete as per requirements
over the external insulated hot water pipes complete as per requirement.
3
(Insulation blankets should have a density of 24 Kg/m ) Twiga make or
equivalent.
-
For 20mm dia
2.1 MR
Metre 15.00 345.00 5,175
For 25mm Dia
2.2 MR
Metre 45.00 370.00 16,650
For 32mm dia
2.3 MR
Metre 145.00 405.00 58,725
For 40mm dia
2.4 MR
Metre 50.00 430.00 21,500
3 Providing and cladding 28 gauge aluminum sheets cladding with 25mm
overlap and fixing with self tapping recessed screws, complete as per
requirements over the insulated hot water pipes as per above item for
external insulation.
-
For 20mm dia
3.1 MR 2,025
Metre 15.00 135.00
For 25mm Dia
3.2 MR 6,750
Metre 45.00 150.00
For 32mm dia
3.3 MR 23,925
Metre 145.00 165.00
For 40mm dia
3.4 MR 9,000
Metre 50.00 180.00

195
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing forged brass lever operated ball valve of full flow with
forged brass ball (Machined to mirror smooth finsh with hard chrome plated)
and spindle with setting and gland of superior quality having minimum
4
working pressure of 10 kg/cm2 etc. complete in all respect.

-
32 mm nominal bore.
4.1 MR
Each 12.00 1,555.00 18,660
40 mm nominal bore
4.2 MR
Each 8.00 2,265.00 18,120
50 mm nominal bore
4.3 MR
Each 14.00 3,300.00 46,200
-
TOTAL C/O TO SUMMARY
767,430
-
MISCELLANEOUS (DSR)
-
IV A -
Providing and placing on terrace (at all floor levels) polyethylene water
CPWD storage tank, ISI : 12701 marked, with cover and suitable locking
1.0 18.48
DSR 2014 arrangement and making necessary holes for inlet, outlet and overflow pipes
liters 50,000.00 7.25 362,500
but without fittings and the base support for tank.
TOTAL C/O TO SUMMARY 362,500

IV B MISCELLANEOUS (NON-DSR)
-
Providing and fixing insect-proof coupling to vent pipes of overhead tank
with threaded or flanged joints, including G.I. flanges, nuts, bolts, 3mm thick
1.0 rubber insertions complete.
-
40mm dia
1.1 MR Each 1.00 740.00 740
50mm dia
1.2 MR Each 2.00 870.00 1,740

196
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing & fixing M.S. structural work fabricated from standard section e.g.
M.S rounds, angles, channels, plates including cutting to size,drilling,welding
fixing and welding to insert plates in RCC structural members as directed by
2.0 MR engineer-in-charge including cutting and making good the walls, ceilings
and floors. (As per the Instructions of the Engineer-In-Charge)

Kg 1,150.00 70.00 80,500


Providing and fixing heavy duty Gunmetal float valve including all required
3 MR accessories complete in all respect as per direction of the engineer -in-
charge . -
40mm dia
3.1 Each 1.00 4,970.00 4,970
50 mm dia
3.2 Each 2.00 5,580.00 11,160
Providing and fixing in position enclosed type water meter (bulk type)
confirming to IS : 2373 including all necessary connecting accessories, T&P,
4 MR labour and materials complete in all respects.

-
40mm dia
4.1 1.00 10,655
Each 10,655.00
50 mm dia
4.2
Each 1.00 14,190.00 14,190
-
TOTAL C/O TO SUMMARY
123,955

197
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATED COST OF RESIDENTIAL TYPE 1 & 2 (BLOCK R3)

SUB HEAD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

IA SANITARY INSTALLATIONS (DSR) 3,193,114


IB SANITARY INSTALLATIONS (NON-DSR) 2,952,541
-
IIA SOIL & WASTE (DSR) 5,784,675

IIB SOIL & WASTE (NON-DSR) 1,691,135


-
IIIA INTERNAL WATER SUPPLY SYSTEM (DSR) 3,014,674

IIIB INTERNAL WATER SUPPLY SYSTEM (NON-DSR) 992,790


-
IVA MISCELLANEOUS (DSR) 36,250

IVB MISCELLANEOUS (NON-DSR) 127,645

INTERNAL PLUMBING COST 17,792,824

LESS 5% FOR UPRNN WORKING (889,641)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 16,903,183

198
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATE FOR RESIDENTIAL BLOCK TYPE 1 & 2

Description of item
item code
S.NO. Dept. Unit Quantity Rate Rs. P. Amount Rs.
no.

IA. SANITARY FIXTURES (DSR ITEMS)

Providing and fixing water closet squatting pan (Indian type W.C. pan )
with100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing
cistern, including flush pipe, with manually controlled device (handle lever)
1.0 17.1
CPWD conforming to IS : 7231, with all fittings and fixtures complete, including
DSR 2014 cutting and making good the walls and floors wherever required:

White Vitreous china Orissa pattern W.C. pan of size 580x440


1.1 17.1.1 mm with integral type foot rests 180.00 610,704
Each 3,392.80
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass
pillar taps, 32 mm C.P. brass waste of standard pattern, including painting
2.0 17.7 of fittings and brackets, cutting and making good the walls wherever
CPWD require:
DSR 2014 -
White Vitreous China Flat back wash basin size 550x 400 mm
2.1 17.7.4 with single 15 mm C.P. brass pillar tap
Each 180.00 1,807.10 325,278
-
Providing and fixing C.P. brass basin mixer of approved quality and make
3.0 18.59 conforming to IS:specification.
MP SOR -
3.1 15 mm nominal bore. Each 180.00 1,759.00 316,620
-
Providing and fixing Stainless Steel A ISI 304 kitchen sink as per IS:13983 with
C.I. brackets and stainless steel plug & 40mm waste coupling including
4.0 CPWD 17.10 painting of fittings and brackets, cutting and making good the walls
DSR 2014 wherever required.
-

199
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
4.1 17.10.1.3 510x1040 mm bowl depth 200 mm (Kichen sink with drain board) Each 112.00 5,996.15 671,569
-
Providing and Fixing C.P. brass Sink mixer of approved quality and make
5.0 18.61 conforming to IS: Specification
MP SOR -
5.1 15 mm nominal bore
Each 112.00 1,724.00 193,088
-
Providing and fixing PTMT soap Dish Holder having length of 138mm,
CPWD breadth 102mm, height of 75mm with concealed fitting arrangements,
6.0 18.65
DSR 2014 weighing not less than 106 gms.
Each 180.00 164.95 29,691
-
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,
200 mm wide with minimum distances of 37 mm from wall face with
CPWD
7.0 17.72 concealed fittings arrangement of approved quality and colour, weighing
DSR 2014
not less than 88 gms.
Each 180.00 218.50 39,330
-
CPWD Providing and fixing C.P. brass angle valve for basin mixer and geyser points
8.0 DSR 2014 18.53 of approved quality conforming to IS:8931 -

8.1 18.53.1 15mm Nominal Bore


Each 1,108.00 507.70 562,532
-
CPWD Providing and Fixing C.P. Brass toilet paper holder,
9.0 17.34.1 Each 180.00 415.90 74,862
DSR 2014
-
CPWD Providing and fixing mirror of superior glass (of approved quality) and of
DSR 2014 required shape and size with plastic moulded frame of approved make and
10.0 17.32 shade with 6 mm thick hard board backing :
-
Rectangular shape 1500x450 mm
10.1 17.32.4 Each 180.00 1,332.45 239,841
-
Providing and fixing in position best indian C.P brass made (0.3 micron
11 MP SOR 25.60 chrom and 10 micron Nickel plated) Double coat hook
Each 180.00 720.00 129,600

TOTAL C/O TO SUMMARY


3,193,114

200
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SANITARY FIXTURES (NON-DSR ITEMS)


IB.
Providing and Fixing C.P brass air purifier container, fixed to wooden cleats
with Stainless Steel screws, complete including making good the walls
1.0 MR wherever required (Make: VIJAY Cat No: 432).

Each 180.00 845.00 152,100


Providing and Fixing straight / offset type flexible single body push fit type WC
pan connector with factory supplied seal guard with integral Single mould
sealing fins made of flexible EVA body, including bush / adaptor for use with
2.0 MR C.I. Pipe as supplied with the pan connector (Make: Viega Cat No: 103668
OR Equivalent ).

Each 180.00 1,751.00 315,181


Providing and Fixing in position storage type Hot Water electrical horizontal
heaters with copper container, insulation, and stove enameled M.S. jacket,
thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia
inlet with non return valve and 15/20mm dia outlet including making
3.0
connections complete in all respects. (wall mounted with suitable M.S. bolts
and nuts) (Make: VENUS OR Equivalent )

3.1 MR Capacity 15 liters


Each 172.00 9,855.00 1,695,060

3.2 MR Capacity 35 liters


Each 60.00 13,170.00 790,200

TOTAL C/O TO SUMMARY


2,952,541

IIA SOIL, WASTE AND VENT PIPES (DSR ITEMS)

1.0 CPWD 17.35 Providing and Fixing soil, waste and vent Pipes
DSR 2014
1.1 17.35.1 100 mm dia

1.2 17.35.1.2 Centrifugally cast (spun) iron Socket and Spigot S&S pipe as per IS: 3989 Meter 3,270.00 917.75 3,001,043

1.3 17.35.2 75 mm Dia -

1.4 17.35.2.2 Centrifugally cast (spun) iron socketed pipe as per IS: 3989 Meter 810.00 791.30 640,953

201
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
CPWD Providing and Fixing G.I. Class "B" pipe complete with G.I. Fittings and angle
2.0 DSR 2014 18.10 suports, clamps, including cutting and making good the walls etc.
-
32 mm dia
2.1 18.10.4 Meter 800.00 343.20 274,560
40 mm dia
2.2 18.10.5 Meter 250.00 425.65 106,413
50 mm dia
2.3 18.10.6 Meter 200.00 527.20 105,440
CPWD Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes
DSR 2014 and fittings with two coats of synthetic enamel paint of any colour such as
3.0 17.65 chocolate grey, or buff etc. over a coat of primer (of approved quality) for
new work : -

3.1 17.65.1 100 mm dia Pipe


Meter 3,270.00 38.65 126,386

3.2 17.65.2 75 mm diameter pipe


Meter 810.00 29.50 23,895
-
CPWD Painting of G.I. Pipes and fittings with two coats of anti-corrosive bitumastic
4.0 DSR 2014 18.40 paint of approved quality.
-
32 mm dia
4.1 18.40.4 Meter 800.00 10.40 8,320
40 mm dia
4.2 18.40.5 Meter 250.00 11.85 2,963
50 mm dia
4.3 18.40.6 Meter 200.00 14.15 2,830
-
CPWD Providing and fixing M.S. holder-bat clamps of approved design to Sand
DSR 2014 Cast iron/cast iron (spun) pipe embedded in and including cement
concrete blocks 10X10X10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
5.0 17.37
graded stone aggregate 20mm nominal size) including cost of cutting holes
and making good the walls etc.
-
For 100mm dia. Pipe
5.1 17.37.1 Each 120.00 152.90 18,348
For 75 mm Dia
5.2 1.37.2 Each 60.00 150.60 9,036

202
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

-
CPWD Providing and fixing bend of required degree with access door, insertion
6.0 DSR 2014 17.38 rubber washer 3mm thick, bolts and nuts complete. -
100mm Dia pipe
6.1 17.38.1 -
Sand cast iron S&S as per IS: 3989
6.2 17.38.1.2 Each 380.00 385.70 146,566
-
CPWD Providing and fixing plain bend of required degree.
7.0 17.39 -
DSR 2014
100mm
7.1 17.39.1 -
Sand cast iron S&S as per IS: 3989
7.2 17.39.1.2 Each 365.00 335.75 122,549
-
CPWD Providing and fixing heel rest sanitary bend
8.0 17.40 -
DSR 2014
100 mm dia
8.1 17.40.1 -
Sand cast iron S&S as per IS: 3989
8.2 17.40.1.2 Each 40.00 371.75 14,870
-
CPWD Providing and fixing single equal plain junction of required degree with
9.0 DSR 2014 17.43 access door, insertion rubber washer 3mm thick, bolts and nuts complete.
-
100x100x100mm
9.1 17.43.1 -
Sand cast iron S&S as per IS: 3989
9.2 17.43.1.2 Each 175.00 623.80 109,165
-
CPWD Providing and Fixing Terminal guard
10.0 17.56 -
DSR 2014
100 mm
10.1 17.56.1 -
Sand cast iron S&S as per IS: 3989
10.2 17.56.1.2 Each 35.00 434.50 15,208
-

203
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
CPWD Providing and Fixing collar: -
11.0 17.57 -
DSR 2014
11.1 17.57.1 100 mm -

11.2 17.57.1.2 Sand cast iron S&S as per IS: 3989 Each 270.00 318.35 85,955
CPWD Providing and fixing door piece, insertion rubber washer 3mm thick, bolts &
12 DSR 2014 17.55 nuts complete : -
12.1 17.55.1 100 mm -
12.2 17.55.1.2 Sand cast iron S&S as per IS: 3989 Each 240.00 513.45 123,228
CPWD Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally
13.0 DSR 2014 17.59 cast (spun) iron pipes of diameter: -

13.1 17.59.1 100mm


Each 40.00 68.60 2,744
CPWD Providing and Fixing trap of self cleansing design with screwed down or
14.0 DSR 2014 17.60 hinged grating with or without vent arm complete, including cost of cutting
and making good the walls and floors. -
14.1 17.60.1 100 mm inlet and 100 mm outlet -
14.2 17.60.1.1 Sand cast iron S&S as per IS: 3989 Each 292.00 982.55 286,905
CPWD Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron
15.0 DSR 2014 17.58 pipes and fittings of diameter :
-

15.1 17.58.1 100 mm diameter pipe 2,000.00 487,500


Meter 243.75
15.2 17.58.2 75 mm diameter pipe 300.00 61,590
Meter 205.30
Making Khurras 45 x 45 cm with average minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20
CPWD mm nominal size) over P.V.C sheet 1 m x 1 m x 400 micron, finished with 12
16.0 12.22
DSR 2014 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
cement rounding the edge and making and finishing the outlet complete.
Each 8.00 186.45 1,492
Making Khurras 30 x 30 cm with average minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20
CPWD mm nominal size) over P.V.C sheet 1 m x 1 m x 400 micron, finished with 12
17.0 Derived
DSR 2014 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
cement rounding the edge and making and finishing the outlet complete.
Each 56.00 120.00 6,720
Total C/O to Summary
5,784,675

204
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

IIB SOIL, WASTE AND VENT PIPES (NON-DSR ITEMS)

Providing and laying cement concrete 1:2:4 mix (1 cement :2 coarse sand 4
1.0 MR stone aggregate 20 mm and downgauge) 75 mm thick in bed and
alround soil and waste pipe under floor of size.100 mm dia
Each 1,420.00 160.00 227,200
Providing and Fixing Floor drain by fixing G.I. Reducing elbow of 100 x 50 mm
in cement concrete 1:2:4 at all levels (exlcuding cost of grating) for
2.0 MR connection to floor traps in sunken portions, complete as per required slope
as per drawings and as per approval of the engineer-in-charge.
Each 180.00 730.00 131,400
Providing and fixing G.I. Inlet fitting with maximum 3 inlets 32,40 & 50 mm size
fabricated from 100 mm dia G.I.pipes and welded G.I. sockets as per site
3.0 MR locations, fixed to C.I. Trap and set in cement concrete as per drawing
complete as per approval of the engineer-in-charge.
Each 292.00 890.00 259,880
Providing and Fixing CP Grating with frame and SS Screws casted heavy duty
125 mm dia including cutting and making good the walls and floors
4.0 MR
wherever required complete in all respects (Make: Vijay Cat No: 1262).
Each 472.00 645.00 304,440
Providing & fixing cast brass clean out plug (FCO & COP) with suitable insert
keys for opening, male threaded joint with G.I. socket caulked to soil
5.0 MR pipe/waste pipe of C.I. and C.I. (LA) pipe as required. (Both for floor & along
ceiling level) -
5.1 100mm dia (Brass) Each 25.00 1,000.00 25,000
Providing and fixing 125mm dia Bronze Chrome plated ring and Grating with
6.0 MR 2 stainless steel screws, ring to be embedded in floor with sealant. (Vijay
Make Cat No : 1262) Each 472.00 645.00 304,440
2
Providing and laying UPVC pipes (I.S:4985) of 10kg./cm including all
fittings with or without access door i.e bends, junctions, cowls, offsets, etc.,
and jointing with solvent cement and excavation, refilling and disposal of
7.0 surplus earth, including cutting holes in walls and floors, excavation, refilling
and disposal of surplus earth wherever required and making good the
same, complete as directed by the Engineer-in-Charge.
-
7.1 MR 75mm outer dia. Metre 265.00 335.00 88,775
7.2 MR 110mm outer dia. Metre 560.00 625.00 350,000
Total C/O to Summary 1,691,135

205
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

WATER SUPPLY (DSR ITEMS) (INTERNAL AND EXTERNAL)


III A

Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having


thermal stability for hot & cold water supply, including all CPVC plain & brass
CPWD threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This
1.0 18.8 includes jointing of pipes & fittings with one step CPVC solvent cement and
DSR 2014
the cost of cutting chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.

Concealed work, including cutting chases and making good the walls etc.

15 mm nominal outer dia Pipes


1.1 18.8.1 Metre 2,860.00 270.00 772,200
20 mm nominal outer dia Pipes
1.2 18.8.2 Metre 2,000.00 296.40 592,800
25 mm nominal outer dia Pipes
1.3 18.8.3 Metre 310.00 351.30 108,903
-
Providing and fixing G.I. class 'B' pipes complete with G.I. fittings, angle
CPWD
2.0 18.10 suports and clamps, i/c cutting and making good the walls etc. exposed on
DSR 2014 -
walls.
2.1 18.10.1 15 mm dia. nominal bore
Metre 60.00 215.10 12,906

2.2 18.10.2 20 mm dia. nominal bore


Metre 290.00 249.30 72,297

2.3 18.10.3 25 mm dia. nominal bore


Metre 455.00 304.15 138,388

2.4 18.10.4 32 mm dia. nominal bore


Metre 460.00 343.20 157,872

2.5 18.10.5 40 mm dia. nominal bore


Metre 425.00 425.65 180,901

2.6 18.10.6 50 mm dia. nominal bore


Metre 380.00 527.20 200,336

2.7 Derived 65 mm dia. nominal bore


Metre 475.00 610.95 290,201

2.8 Derived 80 mm dia. nominal bore


Metre 145.00 709.80 102,921

2.9 Derived 100 mm dia. nominal bore


Metre 20.00 827.75 16,555
-

206
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Painting G.I. pipes and fittings with synthetic enamel white paint with two
CPWD
3.0 18.38 coats over a ready mixed priming coat, both of approved quality for new
DSR 2014 -
work.
3.1 18.38.1 15 mm dia. nominal bore
Metre 60.00 9.60 576

3.2 18.38.2 20 mm dia. nominal bore


Metre 290.00 11.35 3,292

3.3 18.38.3 25 mm diameter pipe.


Metre 455.00 14.95 6,802

3.4 18.38.4 32 mm diameter pipe.


Metre 460.00 17.70 8,142

3.5 18.38.5 40 mm diameter pipe.


Metre 425.00 21.00 8,925

3.6 18.38.6 50 mm diameter pipe


Metre 380.00 24.75 9,405

3.7 Derived 65mm dia. nominal bore


Metre 475.00 28.50 13,538

3.8 Derived 80mm dia. nominal bore


Metre 145.00 32.25 4,676

3.9 Derived 100mm dia. nominal bore


Metre 20.00 36.00 720
-
Providing and fixing G.I. Union heavy class in G.I. Pipe including cutting and
CPWD threading the pipe and making long screws etc. complete (new work)
4.0 18.46
DSR 2014
-

4.1 18.46.1 15mm dia nominal bore


Each 2.00 165.25 331

4.2 18.46.2 20mm dia nominal bore


Each 22.00 188.50 4,147

4.3 18.46.3 25 mm nominal bore


Each 37.00 200.10 7,404

4.4 18.46.4 32 mm nominal bore


Each 38.00 240.75 9,149

4.5 18.46.5 40 mm nominal bore


Each 33.00 316.25 10,436

4.6 18.46.6 50 mm nominal bore


Each 31.00 392.40 12,164

4.7 18.46.7 65mm dia. nominal bore


Each 14.00 636.30 8,908

4.8 18.46.8 80mm dia. nominal bore


Each 12.00 729.25 8,751

4.9 Derived 100mm dia. nominal bore


Each 2.00 822.20 1,644
-

207
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing ball valve (brass) of approved quality, High or low
5.0 18.18 pressure, with plastic floats complete :
-
15 mm nominal bore
5.1 18.18.1
Each 280.00 288.50 80,780
20 mm nominal bore.
5.2 18.18.2
Each 287.00 409.90 117,641
25 mm nominal bore
5.3 18.18.3
Each 9.00 449.95 4,050
-
6 MP SOR 8.6 Providing & Fixing following Cast iron Butterfly Valves including jointing &
testing with cost of jointing of materials like Bolts, nuts and rubber insertion all
complete as per IS : 13095 :1991(class PN 1.6)
-
-
6.1 8.6.2 65 mm nominal bore
Each 1,986.00 20.00 39,720
6.2 8.6.3 80 mm nominal bore
Each 2,168.00 2.00 4,336
6.3 8.6.4 100 mm nominal bore
Each 2,857.00 1.00 2,857
6.4 8.6.5 150 mm nominal bore
Each 4,443.00 -
-
TOTAL C/O TO SUMMARY

3,014,674

208
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
WATER SUPPLY (NON-DSR ITEMS)
III B

1 Insulation for Internal Works

Providing and fixing thermal insulation over hot water pipes in chase having
Red Oxide Primer Coat with 6mm thick 'Kaiflex' /Careflex or approved
equivalent thermal insulation tubing, a elastomeric flexible material having
hermetic blister closed cell structure of expanded synthetic rubber having
density of 60-90 Kg/m3 over pipes of following sizes including all required
accessories complete as per Manufactuer's specifications and finishing it as
per site requirement with Cement Plaster of 1:3 (1 Cement: 3 Coarse sand).

1.1 MR For 15mm Dia


Metre 990.00 295.00 292,050

1.2 MR For 20mm Dia


Metre 800.00 330.00 264,000
2 Insulation for External Works -
Providing and fixing insulation for hot water pipe line with fibre glass wool
blankets/mats of 50mm thickness including cleaning of pipes, wrapping of
mats around the pipe with 50mm overlap on all the sides and sealing the
joints with POP tape, stitching 24 SWG x 20mm G.I wire mesh netting over
MR the mat & cladding 28 gauge aluminum sheets cladding with 25mm overlap
and fixing with self tapping recessed screws, complete as per requirements
over the external insulated hot water pipes complete as per requirement.
(Insulation blankets should have a density of 24 Kg/m3) Twiga make or -
equivalent.
2.1 For 15mm Dia
Metre 35.00 325.00 11,375

2.2 For 20mm dia


Metre 110.00 345.00 37,950

2.3 For 25mm Dia


Metre 180.00 370.00 66,600

2.4 For 32mm dia


Metre 225.00 405.00 91,125

2.5 For 40mm dia


Metre 40.00 430.00 17,200

2.6 For 50mm dia


Metre 20.00 470.00 9,400
2.7 For 65mm dia Metre 40.00 535.00 21,400
-

209
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3 Providing and cladding 28 gauge aluminum sheets cladding with 25mm
overlap and fixing with self tapping recessed screws, complete as per
MR
requirements over the insulated hot water pipes as per above item for
external insulation. -
3.1 For 15mm Dia Metre 35.00 125.00 4,375
3.2 For 20mm dia Metre 110.00 135.00 14,850
3.3 For 25mm Dia Metre 180.00 150.00 27,000
3.4 For 32mm dia Metre 225.00 165.00 37,125
3.5 For 40mm dia Metre 40.00 180.00 7,200
3.6 For 50mm dia Metre 20.00 210.00 4,200
3.7 For 65mm dia Metre 40.00 225.00 9,000
Providing and fixing forged brass lever operated ball valve of full flow with
forged brass ball (Machined to mirror smooth finsh with hard chrome plated)
4.0 MR and spindle with setting and gland of superior quality having minimum
working pressure of 10 kg/cm2 etc. complete in all respect.
-

4.1 32 mm nominal bore.


Each 15.00 1,555.00 23,325

4.2 40 mm nominal bore


Each 11.00 2,265.00 24,915

4.3 50 mm nominal bore


Each 9.00 3,300.00 29,700
-
TOTAL C/O TO SUMMARY
992,790

MISCELLANEOUS (DSR)

IV A
Providing and placing on terrace (at all floor levels) polyethylene water
storage tank, ISI : 12701 marked, with cover and suitable locking
CPWD
1.0 18.48 arrangement and making necessary holes for inlet, outlet and overflow
DSR 2014
pipes but without fittings and the base support for tank.
liters 5,000.00 7.25 36,250

TOTAL C/O TO SUMMARY


36,250

210
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
MISCELLANEOUS (NON-DSR)
IV B

Providing and fixing insect-proof coupling to vent pipes of overhead tank


with threaded or flanged joints, including G.I. flanges, nuts, bolts, 3mm thick
1.0 MR
rubber insertions complete.

40mm dia
1.1 Each 2.00 740.00 1,480
50mm dia
1.2 Each 3.00 870.00 2,610
Providing & fixing M.S. structural work fabricated from standard section e.g.
M.S rounds, angles, channels, plates including cutting to size,drilling,welding
fixing and welding to insert plates in RCC structural members as directed by
2.0 MR engineer-in-charge including cutting and making good the walls, ceilings
and floors. (As per the Instructions of the Engineer-In-Charge)
Kg 1,100.00 70.00 77,000
Providing and fixing heavy duty Gunmetal float valve including all required
3 accessories complete in all respect as per direction of the engineer -in-
charge . -
32mm dia
3.1 MR 1.00 4,360
Each 4,360.00
40mm dia
3.2 MR 1.00 4,970
Each 4,970.00
65 mm dia
3.3 MR 2.00 12,380
Each 6,190.00
Providing and fixing in position enclosed type water meter (bulk type)
confirming to IS : 2373 including all necessary connecting accessories, T&P,
4 labour and materials complete in all respects.
-
40mm dia
4.1 MR 1.00 10,655
Each 10,655.00
50 mm dia
4.2 MR 1.00 14,190
Each 14,190.00
-
TOTAL C/O TO SUMMARY

127,645

211
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATED COST OF RESIDENTIAL TYPE 3 & 4 (BLOCK R1 & R2)

SUBHEAD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

IA SANITARY INSTALLATIONS (DSR) 3,462,981

IB SANITARY INSTALLATIONS (NON-DSR) 3,008,731


-
IIA SOIL & WASTE (DSR) 6,168,495

IIB SOIL & WASTE (NON-DSR) 11,640,825


-
IIIA INTERNAL WATER SUPPLY SYSTEM (DSR) 2,816,577

IIIB INTERNAL WATER SUPPLY SYSTEM (NON-DSR) 621,915


-
IVA MISCELLANEOUS (DSR) 471,250

IVB MISCELLANEOUS (NON-DSR) 232,305

INTERNAL PLUMBING COST 28,423,079

LESS 5% FOR UPRNN WORKING (1,421,154)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 27,001,925

212
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATE FOR RESIDENTIAL BLOCK TYPE 3 & 4

Description of item
item code
S.NO. Dept. Unit Quantity Rate Rs. P. Amount Rs.
no.

IA. SANITARY FIXTURES (DSR ITEMS)

Providing and fixing white vitreous china pedestal type (European type/wash
CPWD down type) water closet pan.
1.0 17.15
DSR 2014
Each 180.00 1,312.40 236,232
-
Extra for using coloured pedestal type W.C pan (European type) with low
CPWD level cistern of same colour instead of white vitreous china W.C pan and
2.0 17.16
DSR 2014 cistern.
Each 180.00 1,446.06 260,291
-
Providing and fixing P.V.C. low level flushing cistern with manually controlled
3.0 17.18 device (handle lever) conforming to IS : 7231, with all fittings and fixtures
CPWD -
complete.
DSR 2014
10 litre capacity - White
3.1 17.18.1 Each 180.00 865.05 155,709
-
Providing and fixing in position best indian Health Faucet with 8 mm dia, 1
4.0 MP SOR 25.37 Meter long Flexible tube & wall bracket with NRV
Each 180.00 1,920.00 345,600
-
Providing and fixing water closet squatting pan (Indian type W.C. pan )
with100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing
cistern, including flush pipe, with manually controlled device (handle lever)
5.0 17.1
CPWD conforming to IS : 7231, with all fittings and fixtures complete, including
DSR 2014 cutting and making good the walls and floors wherever required:
-
White Vitreous china Orissa pattern W.C. pan of size 580x440
5.1 17.1.1 mm with integral type foot rests
Each 30.00 3,392.80 101,784

213
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass
pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of
6.0 17.7
fittings and brackets, cutting and making good the walls wherever require:
CPWD -
DSR 2014
White Vitreous China Flat back wash basin size 550x 400 mm with single 15
6.1 17.7.4 mm C.P. brass pillar tap
Each 210.00 1,807.10 379,491
-
Providing and fixing C.P. brass basin mixer of approved quality and make
7.0 18.59 conforming to IS:specification.
MP SOR -
15 mm nominal bore.
7.1 Each 150.00 1,759.00 263,850
-
Providing and fixing Stainless Steel A ISI 304 kitchen sink as per IS:13983 with
C.I. brackets and stainless steel plug & 40mm waste coupling including
8.0 17.10 painting of fittings and brackets, cutting and making good the walls
CPWD
wherever required.
DSR 2014
-
510x1040 mm bowl depth 200 mm (Kichen sink with drain board)
8.1 17.10.1.3 359,769
Each 60.00 5,996.15
-
Providing and Fixing C.P. brass Sink mixer of approved quality and make
9.0 18.61 conforming to IS: Specification
MP SOR -
15 mm nominal bore
9.1
Each 60.00 1,724.00 103,440
-
Providing and fixing PTMT soap Dish Holder having length of 138mm,
CPWD breadth 102mm, height of 75mm with concealed fitting arrangements,
10.0 18.65
DSR 2014 weighing not less than 106 gms.
Each 360.00 164.95 59,382
-
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,
200 mm wide with minimum distances of 37 mm from wall face with
CPWD
11.0 17.72 concealed fittings arrangement of approved quality and colour, weighing
DSR 2014
not less than 88 gms.
Each 210.00 218.50 45,885

214
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
Providing and Fixing 15 mm nominal bore CP Brass bib cock of approved
12.0 18.49 quality conforming to IS: 8931.
CPWD
-
DSR 2014
15 mm nomial bore
12.1 18.49.1 Each 60.00 459.50 27,570
-
Providing and fixing C.P. brass angle valve for basin mixer and geyser points
13.0 18.53 of approved quality conforming to IS:8931
CPWD
-
DSR 2014
15mm Nominal Bore
13.1 18.53.1 Each 1,260.00 507.70 639,702
-
CPWD Providing and Fixing C.P. Brass toilet paper holder,
14.0 17.34.1 Each 180.00 415.90 74,862
DSR 2014
-
Providing and fixing mirror of superior glass (of approved quality) and of
required shape and size with plastic moulded frame of approved make and
15.0 17.32 shade with 6 mm thick hard board backing :
CPWD
DSR 2014 -
Rectangular shape 1500x450 mm
15.1 17.32.4
Each 210.00 1,332.45 279,815

-
Providing and fixing in position best indian C.P brass made (0.3 micron
16.0 MP SOR 25.60 chrom and 10 micron Nickel plated) Double coat hook
Each 180.00 720.00 129,600

TOTAL C/O TO SUMMARY


3,462,981

215
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SANITARY FIXTURES (NON-DSR ITEMS)
IB.

Providing and Fixing C.P brass air purifier container, fixed to wooden cleats
with Stainless Steel screws, complete including making good the walls
1.0 MR
wherever required (Make: VIJAY Cat No: 432).
Each 150.00 845.00 126,750
-
Providing and Fixing straight / offset type flexible single body push fit type WC
pan connector with factory supplied seal guard with integral Single mould
sealing fins made of flexible EVA body, including bush / adaptor for use with
2.0 MR
C.I. Pipe as supplied with the pan connector (Make: Viega Cat No: 103668
OR Equivalent ).
Each 180.00 1,751.00 315,181
-
Providing and Fixing in position storage type Hot Water electrical horizontal
heaters with copper container, insulation, and stove enameled M.S. jacket,
thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia
3.0 inlet with non return valve and 15/20mm dia outlet including making
connections complete in all respects. (wall mounted with suitable M.S. bolts
and nuts) (Make: VENUS OR Equivalent )
-
Capacity 15 liters
3.1 MR Each 60.00 9,855.00 591,300
Capacity 35 liters
3.2 MR Each 150.00 13,170.00 1,975,500

TOTAL C/O TO SUMMARY


3,008,731

216
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SOIL, WASTE AND VENT PIPES (DSR ITEMS)
IIA

1.0 CPWD 17.35 Providing and Fixing soil, waste and vent Pipes
DSR 2014
1.1 17.35.1 100 mm dia

1.2 17.35.1.2 Centrifugally cast (spun) iron Socket and Spigot S&S pipe as per IS: 3989 Meter 3,980.00 917.75 3,652,645

1.3 17.35.2 75 mm Dia -

1.4 17.35.2.2 Centrifugally cast (spun) iron socketed pipe as per IS: 3989 Meter 725.00 791.30 573,693
-
CPWD Providing and Fixing G.I. Class "B" pipe complete with G.I. Fittings and angle
2.0 DSR 2014 18.10 suports, clamps, including cutting and making good the walls etc.
-

2.1 18.10.4 32 mm dia


Meter 595.00 343.20 204,204

2.2 18.10.5 40 mm dia


Meter 135.00 425.65 57,463

2.3 18.10.6 50 mm dia


Meter 165.00 527.20 86,988
-
CPWD Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes
DSR 2014 and fittings with two coats of synthetic enamel paint of any colour such as
3.0 17.65
chocolate grey, or buff etc. over a coat of primer (of approved quality) for
new work : -

3.1 17.65.1 100 mm dia Pipe


Meter 3,980.00 38.65 153,827

3.2 17.65.2 75 mm diameter pipe


Meter 725.00 29.50 21,388
-
CPWD Painting of G.I. Pipes and fittings with two coats of anti-corrosive bitumastic
4.0 DSR 2014 18.40 paint of approved quality. -

4.1 18.40.4 32 mm dia


Meter 595.00 10.40 6,188

4.2 18.40.5 40 mm dia


Meter 135.00 11.85 1,600

4.3 18.40.6 50 mm dia


Meter 165.00 14.15 2,335
-

217
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
CPWD Providing and fixing M.S. holder-bat clamps of approved design to Sand
DSR 2014 Cast iron/cast iron (spun) pipe embedded in and including cement
5.0 17.37 concrete blocks 10X10X10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) including cost of cutting holes
and making good the walls etc.
-
For 100mm dia. Pipe
5.1 17.37.1 Each 130.00 152.90 19,877
For 75 mm Dia
5.2 1.37.2 Each 50.00 150.60 7,530
-
CPWD Providing and fixing bend of required degree with access door, insertion
6.0 DSR 2014 17.38 rubber washer 3mm thick, bolts and nuts complete.
-

6.1 17.38.1 100mm Dia pipe


-

6.2 17.38.1.2 Sand cast iron S&S as per IS: 3989 Each 320.00 385.70 123,424
-

7.0 CPWD 17.39 Providing and fixing plain bend of required degree.
-
DSR 2014
7.1 17.39.1 100mm
-

7.2 17.39.1.2 Sand cast iron S&S as per IS: 3989 Each 330.00 335.75 110,798
-

8.0 CPWD 17.40 Providing and fixing heel rest sanitary bend
-
DSR 2014
8.1 17.40.1 100 mm dia
-

8.2 17.40.1.2 Sand cast iron S&S as per IS: 3989 Each 20.00 371.75 7,435
-
CPWD Providing and fixing single equal plain junction of required degree with
9.0 DSR 2014 17.43 access door, insertion rubber washer 3mm thick, bolts and nuts complete.
-

9.1 17.43.1 100x100x100mm -

9.2 17.43.1.2 Sand cast iron S&S as per IS: 3989 Each 75.00 623.80 46,785
-
CPWD Providing and Fixing Terminal guard
10.0 17.56 -
DSR 2014

218
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
100 mm
10.1 17.56.1 -
Sand cast iron S&S as per IS: 3989
10.2 17.56.1.2 Each 50.00 434.50 21,725
-

11.0 CPWD 17.57 Providing and Fixing collar: - -


DSR 2014
11.1 17.57.1 100 mm -

11.2 17.57.1.2 Sand cast iron S&S as per IS: 3989 Each 300.00 318.35 95,505
-
CPWD Providing and fixing door piece, insertion rubber washer 3mm thick, bolts &
12 DSR 2014 17.55 nuts complete : -

12.1 17.55.1 100 mm -

12.2 17.55.1.2 Sand cast iron S&S as per IS: 3989 Each 250.00 513.45 128,363
-
CPWD Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally
13.0 DSR 2014 17.59 cast (spun) iron pipes of diameter: -

13.1 17.59.1 100mm 2,744


Each 40.00 68.60
-
CPWD Providing and Fixing trap of self cleansing design with screwed down or
14.0 DSR 2014 17.60 hinged grating with or without vent arm complete, including cost of cutting
and making good the walls and floors. -

14.1 17.60.1 100 mm inlet and 100 mm outlet -

14.2 17.60.1.1 Sand cast iron S&S as per IS: 3989 Each 270.00 982.55 265,289
-
CPWD Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron
15.0 DSR 2014 17.58 pipes and fittings of diameter : -

15.1 17.58.1 100 mm diameter pipe


Meter 2,065.00 243.75 503,344

15.2 17.58.2 75 mm diameter pipe


Meter 250.00 205.30 51,325
-

219
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Making Khurras 45 x 45 cm with average minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20
CPWD mm nominal size) over P.V.C sheet 1 m x 1 m x 400 micron, finished with 12
16.0 12.22
DSR 2014 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
cement rounding the edge and making and finishing the outlet complete.
Each 13.00 186.45 2,424
-
Making Khurras 30 x 30 cm with average minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20
CPWD mm nominal size) over P.V.C sheet 1 m x 1 m x 400 micron, finished with 12
17.0 Derived
DSR 2014 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
cement rounding the edge and making and finishing the outlet complete.
Each 180.00 120.00 21,600
-
Total C/O to Summary 6,168,495

IIB SOIL, WASTE AND VENT PIPES (NON-DSR ITEMS) -


-
Providing and fixing centrifugally cast (spun) iron soil, waste and vent pipes
as per IS:3989 including all fittings with or without access door of any degree
i.e bends, junctions, cowls, offsets, access pieces, G.I. holder bats and
clamps, stays, etc and jointing with refined pig lead / approved type
1.0 MR sealant compound (dripseal) joints including painting with two coats of
synthetic enamel paint of approved quality & cutting holes in walls and
floors, excavation, refilling and disposal of surplus earth wherever required
and making good the same complete, as directed by the Engineer-in-
charge.150 mm Dia Meter 380.00 2,645.00 1,005,100
-
Providing and laying cement concrete 1:2:4 mix (1 cement :2 coarse sand 4
stone aggregate 20 mm and downgauge) 75 mm thick in bed and
2.0 MR
alround soil and waste pipe under floor of size.100 mm dia
Each 1,425.00 160.00 228,000
-
Providing and Fixing Floor drain by fixing G.I. Reducing elbow of 100 x 50 mm
in cement concrete 1:2:4 at all levels (exlcuding cost of grating) for
3.0 MR connection to floor traps in sunken portions, complete as per required slope
as per drawings and as per approval of the engineer-in-charge. 43,800
Each 60.00 730.00
-

220
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing G.I. Inlet fitting with maximum 3 inlets 32,40 & 50 mm size
fabricated from 100 mm dia G.I.pipes and welded G.I. sockets as per site
4.0 MR locations, fixed to C.I. Trap and set in cement concrete as per drawing
complete as per approval of the engineer-in-charge.
Each 270.00 890.00 240,300
Providing and Fixing CP Grating with frame and SS Screws casted heavy duty
5.0 MR 125 mm dia including cutting and making good the walls and floors
wherever required complete in all respects (Make: Vijay Cat No: 1262). Each 420.00 645.00 270,900
Providing & fixing cast brass clean out plug (FCO & COP) with suitable insert
keys for opening, male threaded joint with G.I. socket caulked to soil
6.0 MR pipe/waste pipe of C.I. and C.I. (LA) pipe as required. (Both for floor & along
ceiling level)
-
6.1 150mm dia (M.S. / G.I.) Each 20.00 1,520.00 30,400
Providing and fixing 125mm dia Bronze Chrome plated ring and Grating with
2 stainless steel screws, ring to be embedded in floor with sealant. (Vijay
7 MR
Make Cat No : 1262)
Each 330.00 645.00 212,850
Providing and fixing pre-fab polymer concrete channels conforming to
relevant EN standards with V-shaped profile, tounge and groove jointing
arrangement, in-built ductile iron edge rail, with in-built slope along the
complete length of the channel, and polymer concrete channels to be
8 MR made of zero water absorbtion, of density being 2.1 - 2.3gm/cm3, with
surface roughness of aprox 25 μm, complete including all necessary civil and
finishing works as required as per site and the instructions of the engineer - in -
charge, (Make: ACO or approved equivalent) for following sizes:Size 350 x
385 mm (B x H) Metre 220.00 39,420.00 8,672,400
2
Providing and laying UPVC pipes (I.S:4985) of 10kg./cm including all
fittings with or without access door i.e bends, junctions, cowls, offsets, etc.,
and jointing with solvent cement and excavation, refilling and disposal of
9.0 MR
surplus earth, including cutting holes in walls and floors ,wherever required
and making good the same, complete as directed by the Engineer-in-
Charge. -

9.1 75mm outer dia.


Metre 745.00 335.00 249,575

9.2 110mm outer dia.


Metre 1,100.00 625.00 687,500

Total C/O to Summary


11,640,825

221
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
WATER SUPPLY (DSR ITEMS) (INTERNAL AND EXTERNAL)
III A -
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply, including all CPVC plain & brass
CPWD threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This
1.0 18.8 includes jointing of pipes & fittings with one step CPVC solvent cement and
DSR 2014
the cost of cutting chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.
-
Concealed work, including cutting chases and making good the walls etc.
-

1.1 18.8.1 15 mm nominal outer dia Pipes


Metre 2,650.00 270.00 715,500

1.2 18.8.2 20 mm nominal outer dia Pipes


Metre 760.00 296.40 225,264

1.3 18.8.3 25 mm nominal outer dia Pipes


Metre 50.00 351.30 17,565
-
Providing and fixing G.I. class 'B' pipes complete with G.I. fittings, angle
CPWD
2.0 18.10 suports and clamps, i/c cutting and making good the walls etc. exposed on
DSR 2014 -
wall.
2.1 18.10.1 15 mm dia. nominal bore Metre 215.10 13,982
65.00
2.2 18.10.2 20 mm dia. nominal bore Metre 249.30 211,905
850.00
2.3 18.10.3 25 mm dia. nominal bore Metre 304.15 203,781
670.00
2.4 18.10.4 32 mm dia. nominal bore Metre 343.20 401,544
1,170.00
2.5 18.10.5 40 mm dia. nominal bore Metre 425.65 125,567
295.00
2.6 18.10.6 50 mm dia. nominal bore Metre 527.20 395,400
750.00
2.7 Derived 65 mm dia. nominal bore Metre 610.95 76,369
125.00
2.8 Derived 80 mm dia. nominal bore Metre 709.80 42,588
60.00
2.9 Derived 100 mm dia. nominal bore Metre 827.75 4,139
5.00
-

222
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Painting G.I. pipes and fittings with synthetic enamel white paint with two
CPWD
3.0 18.38 coats over a ready mixed priming coat, both of approved quality for new
DSR 2014 -
work

3.1 18.38.1 15 mm dia. nominal bore Metre 9.60 624


65.00
3.2 18.38.2 20 mm dia. nominal bore Metre 11.35 9,648
850.00
3.3 18.38.3 25 mm diameter pipe. Metre 14.95 10,017
670.00
3.4 18.38.4 32 mm diameter pipe. Metre 17.70 20,709
1,170.00
3.5 18.38.5 40 mm diameter pipe. Metre 21.00 6,195
295.00
3.6 18.38.6 50 mm diameter pipe Metre 24.75 18,563
750.00
3.7 Derived 65mm dia. nominal bore Metre 28.50 3,563
125.00
3.8 Derived 80mm dia. nominal bore Metre 32.25 1,935
60.00
3.9 Derived 100mm dia. nominal bore Metre 36.00 180
5.00
-
Providing and fixing G.I. Union heavy class in G.I. Pipe including cutting and
CPWD
4.0 18.46 threading the pipe and making long screws etc. complete (new work)
DSR 2014 -
15mm dia nominal bore
4.1 18.46.1 Each 1.00 165.25 165

4.2 18.46.2 20mm dia nominal bore


Each 75.00 188.50 14,138
25 mm nominal bore
4.3 18.46.3 Each 56.00 200.10 11,206
32 mm nominal bore
4.4 18.46.4 Each 100.00 240.75 24,075
40 mm nominal bore
4.5 18.46.5 Each 31.00 316.25 9,804
50 mm nominal bore
4.6 18.46.6 Each 66.00 392.40 25,898

4.7 18.46.7 65mm dia. nominal bore


Each 11.00 636.30 6,999
80mm dia. nominal bore
4.8 18.46.8 Each 6.00 729.25 4,376

4.9 Derived 100mm dia. nominal bore


Each 1.00 822.20 822
-

223
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing ball valve (brass) of approved quality, High or low
5.0 18.18 pressure, with plastic floats complete : -

5.1 18.18.1 15 mm nominal bore Each 330.00 288.50 95,205

5.2 18.18.2 20 mm nominal bore. Each 228.00 409.90 93,457

5.3 18.18.3 25 mm nominal bore Each 2.00 449.95 900


-
6 8.6 Providing & Fixing following Cast iron Butterfly Valves including jointing &
MP SOR testing with cost of jointing of materials like Bolts, nuts and rubber insertion all
complete as per IS : 13095 :1991(class PN 1.6) -
-
6.1 8.6.2 65 mm nominal bore Each 1,986.00 4.00 7,944
6.2 8.6.3 80 mm nominal bore Each 2,168.00 5.00 10,840
6.3 8.6.4 100 mm nominal bore Each 2,857.00 2.00 5,714
-
TOTAL C/O TO SUMMARY
2,816,577
-
WATER SUPPLY (NON-DSR ITEMS)
III B -
-

1 Insulation for Internal Works


-
Providing and fixing thermal insulation over hot water pipes in chase having
Red Oxide Primer Coat with 6mm thick 'Kaiflex' /Careflex or approved
equivalent thermal insulation tubing, a elastomeric flexible material having
MR hermetic blister closed cell structure of expanded synthetic rubber having
density of 60-90 Kg/m3 over pipes of following sizes including all required
accessories complete as per Manufactuer's specifications and finishing it as
per site requirement with Cement Plaster of 1:3 (1 Cement: 3 Coarse sand).
-

1.1 For 15mm Dia


Metre 780.00 295.00 230,100
For 20mm Dia
1.2
Metre 180.00 330.00 59,400

224
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2 Insulation for External Works -
Providing and fixing insulation for hot water pipe line with fibre glass wool
blankets/mats of 50mm thickness including cleaning of pipes, wrapping of
mats around the pipe with 50mm overlap on all the sides and sealing the
joints with POP tape, stitching 24 SWG x 20mm G.I wire mesh netting over
MR the mat & cladding 28 gauge aluminum sheets cladding with 25mm overlap
and fixing with self tapping recessed screws, complete as per requirements
over the external insulated hot water pipes complete as per requirement.
(Insulation blankets should have a density of 24 Kg/m3) Twiga make or
equivalent. -
2.1 For 20mm dia Metre 90.00 345.00 31,050
2.2 For 25mm Dia Metre 90.00 370.00 33,300
2.3 For 32mm dia Metre 135.00 405.00 54,675
2.4 For 40mm dia Metre 10.00 430.00 4,300
2.5 For 50mm dia Metre 35.00 470.00 16,450
-
3 Providing and cladding 28 gauge aluminum sheets cladding with 25mm
overlap and fixing with self tapping recessed screws, complete as per
MR
requirements over the insulated hot water pipes as per above item for
external insulation. -

3.1 For 20mm dia Metre 90.00 135.00 12,150

3.2 For 25mm Dia Metre 90.00 150.00 13,500

3.3 For 32mm dia Metre 135.00 165.00 22,275

3.4 For 40mm dia 1,800


Metre 10.00 180.00
3.5 For 50mm dia 7,350
Metre 35.00 210.00
-
Providing and fixing forged brass lever operated ball valve of full flow with
forged brass ball (Machined to mirror smooth finsh with hard chrome plated)
4 MR and spindle with setting and gland of superior quality having minimum
working pressure of 10 kg/cm2 etc. complete in all respect.
-

4.1 32 mm nominal bore. 52,870


Each 34.00 1,555.00
4.2 40 mm nominal bore 6,795
Each 3.00 2,265.00
4.2 50 mm nominal bore 75,900
Each 23.00 3,300.00
TOTAL C/O TO SUMMARY 621,915

225
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
MISCELLANEOUS (DSR) -
IV A -
Providing and placing on terrace (at all floor levels) polyethylene water
CPWD storage tank, ISI : 12701 marked, with cover and suitable locking
1.0 18.48 arrangement and making necessary holes for inlet, outlet and overflow pipes
DSR 2014
but without fittings and the base support for tank.
liters 65,000.00 7.25 471,250
TOTAL C/O TO SUMMARY
471,250

IV B MISCELLANEOUS (NON-DSR) -
-
Providing and fixing insect-proof coupling to vent pipes of overhead tank
with threaded or flanged joints, including G.I. flanges, nuts, bolts, 3mm thick
1.0 MR
rubber insertions complete.
-
1.1 65mm dia Each 7.00 1,000.00 7,000
-
Providing & fixing M.S. structural work fabricated from standard section e.g.
M.S rounds, angles, channels, plates including cutting to size,drilling,welding
2.0 MR fixing and welding to insert plates in RCC structural members as directed by
engineer-in-charge including cutting and making good the walls, ceilings
and floors. (As per the Instructions of the Engineer-In-Charge) Kg 2,500.00 70.00 175,000
-
Providing and fixing heavy duty Gunmetal float valve including all required
3 MR accessories complete in all respect as per direction of the engineer -in-
charge . -
3.1 32mm dia Each 2.00 4,360.00 8,720
3.2 50 mm dia Each 3.00 5,580.00 16,740
-
Providing and fixing in position enclosed type water meter (bulk type)
confirming to IS : 2373 including all necessary connecting accessories, T&P,
4 MR
labour and materials complete in all respects.
-
4.1 40mm dia Each 1.00 10,655.00 10,655
4.2 50 mm dia Each 1.00 14,190.00 14,190
-
TOTAL C/O TO SUMMARY
232,305

226
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATED COST OF EXTERNAL PHE PLUMBING WORKS-SEWERAGE & DRAINAGE SYSTEM, DOMESTIC
WATER SUPPLY/FLUSING/GARDEN HYDRANT LINE

SUBHEAD OF WORKS
SUBHE AD ESTIMATED
NO AMOUNT IN INR

EXTERNAL D1528 (DSR)


IA 11,643,381

EXTERNAL SEWERAGE & DRAINAGE SYSTEM (NON-DSR)


IB 11,600,265

EXTERNAL DOMESTIC WATER SUPPLY / FLUSHING / GARDEN HYDRANT LINE (DSR )


IIA 5,741,892
EXTERNAL DOMESTIC WATER SUPPLY / FLUSHING / GARDEN HYDRANT LINE (NON-DSR )
IIB 15,417,760
TOTAL
44,403,298

LESS 5% FOR UPRNN WORKING (2,220,165)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 42,183,133

SUBJECT: ESTIMATE FOR EXTERNAL PHE SERVICES

227
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATED COST OF ADMINISTRATIVE AND ACADEMIC BLOCK

Description of item
item code
S.NO. Dept. Unit Quantity Rate Amount Rs.
no.

VA EXTERNAL SEWERAGE AND DRAINAGE SYSTEM (DSR ITEMS)

Excavation trenches of required width for pipes etc., including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m,
CPWD including getting out the excavated soil, and then returning soil as required,
1.0 2.10 in layers not exceeding 20cm in depth including consolidating each
DSR 2014
deposited layer by ramming, watering etc. and disposing of surplus
excavated soil as directed within a lead of 50 m.

All Kinds of Soil


2.10.1

Pipes etc., exceeding 80mm dia but not exceeding 300mm dia
1.1 2.10.1.2 604,070
Metre 2,900.00 208.30

Excavating trenches of required width for pipes, cables, etc, including


excavation for sockets, depth upto 1.5 m, including getting out the
excavated materials, returning the soil as required in layers not exceeding 20
CPWD
2.0 2.13 cm in depth, including consolidating each deposited layers by ramming,
DSR 2014
watering etc., stacking serviceable material for measurements and disposal
of unserviceable material as directed, within a lead of 50 m :
-

2.1 2.13.1 Ordinary rock :


-

2.1.1 2.13.1.2 Pipes etc., exceeding 80mm dia but not exceeding 300mm dia
Metre 1,050.00 450.30 472,815

-
2.2 2.13.3 Hard rock (blasting prohibited)
-

228
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.13.3.2 Pipes etc., exceeding 80mm dia but not exceeding 300mm dia
2.2.1 Metre 1,050.00 870.70 914,235
-
Providing, Laying and jointing glazed stoneware pipe Class SP1 with stiff
CPWD mixture of cement mortar in the proportion of 1:1 (1 Cement: 1 Find sand)
3.0 19.1
DSR 2014 including testing of joints etc. complete. -
150 mm diameter
3.1 19.1.2 Metre 450.00 314.35 141,458
200 mm diameter
3.2 19.1.3 Metre 1,550.00 462.15 716,333
250 mm diameter
3.3 19.2.3 Metre 50.00 696.50 34,825
-
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with
CPWD collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1
4.0 19.6
DSR 2014 cement : 2 fine sand) including testing of joints etc. complete :
-

4.1 Derived 200 mm dia. R.C.C. pipe 43,000


Metre 100.00 430.00
4.2 19.6.3 250 mm dia. R.C.C. pipe 796,620
Metre 1,700.00 468.60
4.3 19.6.4 300 mm dia. R.C.C. pipe 278,493
Metre 550.00 506.35
4.4 Derived 400 mm dia. R.C.C. pipe 165,000
Metre 300.00 550.00
4.5 19.6.5 450 mm dia. R.C.C. pipe 176,475
Metre 250.00 705.90
4.6 19.6.6 500 mm dia. R.C.C. pipe 84,069
Metre 90.00 934.10

Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4


coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix
(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size),
CPWD
5.0 19.7 inside plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse
DSR 2014
sand) finished with floating coat of neat cement and making channels in
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a floating coat of neat cement
complete as per standard design : -
-

229
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light
CPWD duty) 455x610 mm internal dimensions, total weight of cover and frame to be
5.1 19.7.1
DSR 2014 not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
-
-
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
5.1.1 19.7.1.1 Each 8,507.00 595,490
70.00
-
CPWD Extra depth for Manholes
5.2 19.8 -
DSR 2014
5.2.1 19.8.1 Size 90x80 cm
-
5.2.1.1 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 40.00 5,638.20 225,528
-
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame
CPWD (medium duty) 500 mm internal diameter, total weight of cover and frame to
5.2 19.7.2
DSR 2014 be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
-
-
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
5.2.1 19.7.2.1 Each 18,304.45 732,178
40.00
-
CPWD Extra depth for Manholes
6.0 19.8 -
DSR 2014
6.1 19.8.2 Size 120x90 cm -
-
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
6.1.1 19.8.2.1
Metre 20.00 6,753.65 135,073
-
Constructing Brick Masonry circular type manhole 0.91 m internal dia at
bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 Coarse
sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement :
3 coarse sand) finished with a floating coat of neat cement, 150 mm
CPWD foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone
7.0 19.9
DSR 2014 aggregate 40mm nominal size) and making necessary channel in Cement
Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone aggregate
20mm nominal size) finished with a floating coat of neat cement all
complete as per standard design. -
-

230
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
0.91m deep with SFRC cover and frame (heavy duty HD-20 grade
designation) 560mm internal diameter conforming to I.S:12592, total weight
of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4
CPWD mix (1 Cement: 2 Coarse sand: 4 Graded stone aggregate 20mm nominal
7.1 19.9.1
DSR 2014 size) including centering, shuttering all complete. (Excavation, foot rests and
12 mm thick cement plaster at the external surface shall be paid for
separately) -
-
7.1.1 CPWD 19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
DSR 2014 Each 125.00 8,738.55 1,092,319
-
CPWD Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond
7.2 19.10
DSR 2014 0.91 m to 1.67 m -
-
CPWD With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
7.3 19.10.1 Metre 60.00 4,842.40 290,544
DSR 2014
-
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS:
1786, having minimum cross section as 23 mmx25 mm and over all minimum
length 263 mm and width as 165 mm with minimum 112 mm space between
protruded legs having 2 mm tread on top surface by ribbing or chequering
CPWD besides necessary and adequate anchoring projections on tail length on 138
8.0 19.16 mm as per standard drawing and suitable to with stand the bend test and
DSR 2014
chemical resistance test as per specifications and having manufacture’s
permanent identification mark to be visible even after fixing, including fixing
in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as
per design. Each 900.00 311.60 280,440
-
9.0 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10
CPWD
graded stone aggregate 40 mm nominal size) all-round S.W./RCC/CILA
DSR 2014
pipes including bed concrete as per standard design: -
9.1 19.2.1 100 mm diameter Metre 50.00 592.60 29,630

9.2 19.2.2 150 mm diameter 36,235


Metre 50.00 724.70
9.3 19.2.3 200 mm diameter 1,436,245
Metre 1,700.00 844.85
9.4 19.2.4 250 mm diameter 1,612,050
Metre 1,650.00 977.00

231
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
10 CPWD 18.27 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA)
DSR 2014 conforming to IS - 1536 :

10.1 18.27.3 150 mm dia. Pipe Metre 32,335


20.00 1,616.75
10.2 18.27.4 200 mm dia. Pipe Metre 90.00 2,743.50 246,915
10.3 18.27.5 250 mm dia. Pipe Metre 107,465
30.00 3,582.15
10.4 18.27.6 300 mm dia. Pipe Metre 241,468
50.00 4,829.35

CPWD Providing lead caulked joints to spun iron or C.I. pipes and specials, including
11.0 18.28 testing of joints but excluding the cost of pig lead :
DSR 2014 -
150 mm dia pipes
11.1 18.28.3 Each 307.60 3,076
10.00
200 mm dia pipes
11.2 18.28.4
Each 40.00 408.00 16,320
250 mm dia pipes
11.3 18.28.5 Each 509.70 5,097
10.00
300 mm dia pipes
11.4 18.28.6 Each 613.85 12,277
20.00
-
CPWD Supplying pig lead at site of work
12.0 18.29
DSR 2014 Quintal 5.00 10,464.50 52,323
-
Providing and laying S&S C.I. Standard specials such as tees, bends, collars
CPWD tapers and caps etc, suitable for flanged jointing as per IS : 1538 :
13.0 18.66
DSR 2014
-
Up to 300 mm dia
13.1 18.66.1
Quintal 5.00 6,596.55 32,983

TOTAL C/O TO SUMMARY

11,643,381

232
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
EXTERNAL SEWERAGE AND DRAINAGE SYSTEM (NON-DSR ITEMS)
VB

Constructing brick masonry inspection chamber in cement mortar 1:4 ( 1


cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size), 100 mm
foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone
1.0 MR aggregate 40mm nominal size), inside plastering 12mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat
cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) finished with a floating
coat of neat cement complete as per standard design :

Inside size 60x60 cm and 60 cm deep including C.I. cover with frame (light
duty) 455x610 mm internal dimensions, total weight of cover and frame to be
1.1
not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Each 5.00 12,355.00 61,775
2.0 MR Extra depth for Inspection Chamber -
2.1 Size 60x60 cm -
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 2.00 4,300.00 8,600
Constructing brick masonry catch basin with 75 class designation bricks in
cement mortar 1:4 (1 cement: 4 coarse sand) thickness of 230mm, 150mm
thick foundation concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone
aggregate 40mm nominal size) inside and outside plaster in cement mortar
3.0 MR 1:3 (1 cement: 3 coarse sand). inside finished with a floating coat of neat
cement, making haunches and channel in cement concrete 1:2:4 (1
cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size)
neatly finished, complete as per standard design including excavation,
refilling and disposal of surplus earth.
-
Size 450X450X450mm inside with D.I. rectangular grating of approved
design and fixed in 150mm thick RCC slab in cement 1:2:4 mix (1 cement: 2
3.1 coarse sand: 4 graded stone aggregate 20mm nominal size) including
centering, shuttering all complete including the cost of reinforcement as per
site conditions. Each 45.00 18,000.00 810,000

233
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Size 600X600X600mm inside with precast D.I. rectangular grating of
approved design and fixed in 150mm thick RCC slab in cement 1:2:4 mix (1
3.2 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size)
including centering, shuttering all complete including the cost of
reinforcement as per site conditions. Each 60.00 20,000.00 1,200,000
Size 750x750x750mm inside with precast D.I. rectangular grating of approved
design and sample fixed in 150 thick RCC slab in cement 1:2:4 mix (1 cement:
3.3 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including
centering, shuttering all complete as per site conditions.
Each 35.00 22,000.00 770,000
Extra for 450X450X450mm catch basin chamber depth exceeding 45cm up
4.0 MR
to 60cm meter 25.00 3,775.00 94,375
Extra for 600X600X600mm catch basin chamber depth exceeding 60cm up
5.0 MR to 75cm 176,400
meter 30.00 5,880.00
-
Extra for 750X750X750mm catch basin chamber depth exceeding 75cm up
6.0 MR to 90cm meter 15.00 6,700.00 100,500
Providing and fixing square mouth 'P' type S.W gully trap grade ‘A‘ of size
180x150mm complete with C.I. grating, brick masonry chamber with bricks of
7.0 MR class designation 75 and water tight double seal C.I. cover with frame of
450x450 mm size (inside). The weight of cover to be not less than 10.0 Kg and
frame to be not less than 4.0 Kg as per standard design.
Each 60.00 4,200.00 252,000
Providing and fixing square mouth 'P' type S.W gully trap Grade ‘A‘ of size
180x150mm complete with C.I. grating, brick masonry 1:4 alround and water
tight C.I. Cover & frame of 450 x 450 mm size (inside) with weight of cover to
be not less then 10 kgs and frame to be not less then 4 kgs including
8.0 MR construction of Brick masonry chamber above Gully Trap of size 900 x800 mm
(inside), with height of 1100 mm duly plasticised in Cement mortar 1:4 and
finished with a floating coat of neat cement inside, and rough plaster on
outside. The Top of Masonry chamber to be covered with RCC slab 1:2:4 with
SFRC M.H. Cover of light duty as per Sketch enclosed.
Each 15.00 10,835.00 162,525

234
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.0 Contsruction of Grease Trap / Oil retention chamber of size 2 m x1 m
(Internal) with effective depth of 1 m with Brick Masonry in Cement 1:4 (1
Cement: 4 Coarse sand) over a bed of 150 mm thick PCC 1:4:8 (1 Cement: 4
Coarse sand: 8 graded stone aggregate 40 mm nominal size) including a
baffle wall of Brick work, covered with RCC slab of 150 mm thickness, of 1:2:4
MR mix (1 Cement: 2 Coarse sand: 4 graded stone aggregate of 20 mm nominal
size) including centering, shuttering and reinforcement complete with
providing and fixing Foot rests @300 mm C to C with Two 600x600 mm DI
Heavy duty Manhole Covers with Lifting arrangement, including 150 mm dia
Inlet & Outlet pipes complete .
Each 2.00 91,670.00 183,340
10.0 Providing and fixing stainless steel grating of any size and shape made from
angles, tees, flats and hinges including the cost of cutting, fitting, welding
the S/S members in the shape and design all as directed by the engineer-in-
MR charge, including polishing and placing the grating over the drain, complete
in all respect as per approved design.

Kg 2,500.00 725.00 1,812,500


11.0 Providing and fixing M.S. grating and preferably in 600mm long pieces,
fabricated with 16x16mm square bars, @ 20mm clear spacing and welded
to angle iron 25x25x5mm and placed firmly on angle iron frame of
30x30x5mm with 25x3mm hold fasts approximately 75mm long welded at
MR intervals of 500mm including two or more coats of synthetic enamel paint of
approved quality and shade over one coats of primer and set in cement
mortar 1:3 (1 cement : 3 coarse sand) complete .

Kg 20,000.00 260.00 5,200,000


Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10
graded stone aggregate 40 mm nominal size) all-round RCC pipes including
12.0 MR bed concrete as per standard design :
-
12.1 300mm dia Metre 550.00 715.00 393,250
12.2 400mm dia Metre 250.00 1,040.00 260,000
12.3 500mm dia Metre 100.00 1,150.00 115,000

TOTAL C/O TO SUMMARY


11,600,265

235
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
EXTERNAL DOMESTIC WATER SUPPLY / FLUSHING / GARDEN HYDRANT LINE/
VI A TUBE WELL LINE (DSR ITEMS) -
1.0 2.10 Excavation of trenches of required width for pipes etc., including excavation
for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m
including getting out the excavated soil, and then returning soil as required,
CPWD including consolidating each deposited layer by ramming, watering etc. and
DSR 2014 disposing of surplus excavated soil as directed outside the site to the
approved dumping ground. Minimum width of the trench should be
external dia plus 400mm as specifed in the specifications in all kinds of soil.
-
1.1 2.10.1.1 Pipes not exceeding 80mm dia Metre 5,430.00 127.55 692,597
1.2 2.10.1.2 Pipes exceeding 80mm dia but not exceeding 300mm dia. 143,727
Metre 690.00 208.30
Painting G.I. pipes and fittings with synthetic enamel white paint with two
CPWD coats over a ready mixed priming coat, both of approved quality for new
2.0 18.38
DSR 2014 work :

2.1 18.38.4 32 mm diameter pipe. Metre 50.00 17.70 885


2.2 18.38.5 40 mm diameter pipe. Metre 100.00 21.00 2,100

3.0 CPWD 18.40 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic
DSR 2014 paint of approved quality : -
3.1 18.40.3 32mm dia Metre 50.00 8.75 438
3.2 18.40.5 40mm dia Metre 520.00 11.85 6,162
3.3 18.40.6 50mm dia Metre 390.00 14.15 5,519
3.4 18.40.7 65mm dia Metre 465.00 17.45 8,114
-
Making connection of G.I. Distribution branch with G.I. main of following sizes
CPWD
4.0 18.13 by providing and fixing tee, including cutting and threading the pipe etc.
DSR 2014
complete. -
4.1 18.13.1 25 to 40 mm nominal bore Each 10.00 367.75 3,678
4.2 18.13.2 50 to 80 mm nominal bore Each 6.00 761.10 4,567
-

236
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement
mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box
100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab
1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm
CPWD
5.0 18.32 nominal size), i/c necessary excavation, 100 mm foundation concrete 1:5:10 (
DSR 2014
1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and
inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm
thick finished with a floating coat of neat cement complete as per standard
design : -
5.1 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 70.00 1,157.75 81,043
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement
mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box
100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside)
with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4
CPWD graded stone aggregate 20mm nominal size ) , i/c necessary excavation, 100
6.0 18.33
DSR 2014 mm foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone
aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3
(1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat
cement complete as per standard design : -
6.1 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 55.00 6,754.30 371,487
7.0 CPWD 18.41 Providing and filling sand of grading zone V or coarser grade 100 mm all-
DSR 2014 round the pipes in external work. -
7.1 18.41.3 25 mm diameter pipe Metre 720.00 69.05 49,716
7.2 18.41.4 32 mm diameter pipe Metre 380.00 70.85 26,923
7.3 18.41.5 40 mm diameter pipe Metre 620.00 71.75 44,485
7.4 18.41.6 50 mm diameter pipe Metre 610.00 74.45 45,415
7.5 18.41.7 65 mm diameter pipe Metre 1,840.00 117.50 216,200
7.6 18.41.8 80 mm diameter pipe Metre 1,250.00 121.10 151,375
7.7 18.41.9 100 mm diameter pipe Metre 700.00 128.25 89,775
7.8 18.41.10 150 mm diameter pipe Metre 60.00 191.05 11,463
8 CPWD 18.73 Providing and laying Double Flanged (Screwed / Welded) Centrifugally
DSR 2014 (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :

8.1 Derived 80mm dia 1,782,500


Meter 1,150.00 1,550.00
8.2 18.73.1 100mm dia Meter 685.00 2,564.75 1,756,854
8.3 18.73.2 150mm dia Meter 60.00 4,114.55 246,873

237
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

TOTAL C/O TO SUMMARY


5,741,892

EXTERNAL DOMESTIC WATER SUPPLY / FLUSHING / GARDEN HYDRANT LINE


VI B (NON-DSR ITEMS) -
-
1 MR Providing, fixing & testing G.I. Pipes (I.S. 1239, heavy duty class) complete
with G.I. Fittings ie tees, elbows, sockets, clamps, with structural steel supports
with galvanised MS slotted angle, spacers as required etc including making
good in treching etc. -
1.1 25mm dia Metre 50.00 445.00 22,250
1.2 40mm dia Metre 520.00 655.00 340,600
1.3 50mm dia Metre 390.00 855.00 333,450
1.4 65mm dia Metre 465.00 1,060.00 492,900
-
2 MR Providing and fixing forged brass lever operated ball valve of full flow with
forged brass ball (Machined to mirror smooth finish with hard chrome plated)
and spindle with setting and gland of superior quality having minimum
working pressure of 10 kg/cm2 etc. complete in all respect.
-
2.1 25 mm nominal bore Each 70.00 1,030.00 72,100
2.2 32 mm nominal bore. Each 6.00 1,555.00 9,330
2.3 40 mm nominal bore Each 7.00 2,265.00 15,855
2.4 50 mm nominal bore Each 3.00 3,300.00 9,900
-
3 MR Providing and laying UPVC pipes (I.S:4985) of 10kg./cm2 including all fittings
with or without access door i.e bends, junctions, cowls, offsets, etc., and
jointing with solvent cement and excavation, refilling and disposal of surplus
earth, including cutting holes in walls and floors ,wherever required and
making good the same, complete as directed by the Engineer-in-Charge.
(For External garden hydrant Pipes only) -

3.1 32mm O.D. 120.00 73,200


Metre 610.00
3.2 40mm O.D. 150.00 42,000
Metre 280.00

238
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.3 50mm O.D. 195.00 19,500
Metre 100.00
3.4 63mm O.D. 255.00 51,000
Metre 200.00
3.5 75mm O.D. 335.00 462,300
Metre 1,380.00
3.6 90mm O.D. 440.00 48,400
Metre 110.00
-
MR Providing and fixing C.I butterfly valve, wafer end type class PN 1.6 as per
4 I.S:13095 or BS:5155, including necessary nuts, bolts, gaskets & flanges etc.,
complete. -

4.1 65 mm nominal bore 17,895


Each 3.00 5,965.00
4.2 80 mm nominal bore 71,250
Each 10.00 7,125.00
4.3 100 mm nominal bore 8,865
Each 1.00 8,865.00
4.4 150 mm nominal bore 13,090
Each 1.00 13,090.00
-
5.0 MR Providing and laying reinforced cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 stone aggregate 20mm nominal size) for anchor/thrust blocks,
complete including shuttering, centering curing, and reinforcement including
removal of shuttering complete.
cum 450.00 5,535.00 2,490,750

MR Providing & fixing M.S. structural work fabricated from standard section e.g.
M.S rounds, angles, channels, plates including cutting to size,drilling,welding
fixing and welding to insert plates in RCC structural members as directed by
6.0 engineer-in-charge including cutting and making good the walls, ceilings
and floors. (As per the Instructions of the Engineer-In-Charge)
Kg 2,500.00 70.00 175,000
7.0 MR Making connection from existing Municipal / external main water line by
drilling/cutting, fixing ferrule and making connection with service pipe
complete including excavation, refilling, disposal of surplus earth and
supplying all material so as to make it functional and also obtaining
necessary permission from all concerned Authorities if it is necessary to break
or excavate the road for laying pipes and making connection, it should be
restored to its Original condition.
Job 1.00 25.00 25

239
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.0 MR Construction of rain water harvesting well of 4.5 metre dia and 4.5 metre
effective depth with the operation of earth work in excavation and drilling
with RC/DC/Calyx rig having 400/450mm dia bore size in all kind of starta
except hard rock, back filling with available exavated earth, with necessary
compaction and shifting of surplus earth outside by mechanical means as
directed by the Project Incharge, PCC 1:5:10 , 200mm thick foundation
concrete, brick work in cement mortar 1:4 (1 cement : 4 coarse sand), PVC
coated safety steel foot rest of 12mm dia MS bars grouted rigidly in cement
concrete 1:2:4 @300mm c/c, 200mm thick RCC tank cover slab in cement
concrete M20 i/c providing and placing necessary steel raft, bars and to
keep the provision of removable slab of approx. 1mx1m size, filling 500mm,
500mm & 500mm thick of 40-63mm nominal size graded stone aggregate,10-
12.5 mm nominal sizes fraded stone aggregate and 1.5 to 2.0 mm coarse
sand layer respectively, CI vent pipe, (100mm dia), 200mm dia uPVC
medium well casing pipe conforming to IS:12818, filling around the casing
pipes and packing 3mm to 6mm sized graded and screened rounded pea
gravel duly washed fabricating and placing grating at the mouth of pipes,
placing 560mm dia SFRC manhole cover with frame etc. i/e all necessary
materials and equipments required for all relevant operations as shown in the
drawing. Each 19.00 465,000.00 8,835,000
-
9 MR Construction of brick masonry desilting chamber of size 200x100x60cm
(effective depth) before rainy well with 75 class designation bricks in
cement mortar 1:4 (1 cement : 4 coarse sand) , foundation concrete 1:4:8
mix (1 cement : 4 coarse sand; 8 graded stone aggregate 40mm nominal
size), inside and outside plastering 12mm thick with cement mortar 1:3 (1
cement : 3 coarse sand), finished with a floating coat of neat cement
inside and rough plaster on outside, including fixing of grating , neatly
finished complete in all respects including neccessary excavation, refilling
and disposal of surplus earth, complete as per attached Sketch.
Each 19.00 95,000.00 1,805,000
10 MR Providing and fixing impact driven, rotary type sprinklers of heavy duty
plastic / non-corrosive & UV resistant body suitable for a throw of approx. 11
to 15 m radius, at operating pressure of approx. 2.5 to 4 Kg/cm, with
adjustable arm complete as per requirement for following discharge ranges:
(Make- Jain Irrigation or Equivalent.)Discharge of 0.1 to 0.2 LPS
Each 18.00 450.00 8,100

TOTAL C/O TO SUMMARY


15,417,760

240
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTMATED COST- SEWAGE TREATMENT PLANT


ITEM DESCRIPTION
S. REF CODE RATE AMOUNT
UNIT QTY
NO. (Rs) (Rs.)
DSR 2014

VIII SEWERAGE TREATMENT PLANT (CAPACITY: 185 KLD)

1 Name of Work: Designing, Preparation of Shop Drawings, Supplying,


Erection, Testing, Commissioning, handing over, operation &
maintenance for 2 years, including purchase and usage of chemical /
consumables for operation and maintenance of all Mechanical,
Electrical, and other components including getting approval of
successful test results from approved Government pollution &
environmental authorities, Operating & Maintaining upto successful
commissioning, for Sewage Treatment Plant, as per Tender Document
comprising General Conditions, Technical Specifications, Data,
Drawings and Annexures and any other documents attached with this
Tender. (Any item not specifically mentioned in these sections but
required for the successful completion including handing over,
extended DLP, Operation & Maintenance of the STP shall be included
in the Quote by the Contractor.)

-
1.1 Cost for Designing, Supply, Installation, testing & Commissioning
handing over, operation & maintenance upto successful
commissioning, including purchase and usage of chemical /
consumables for operation and maintenance of all Mechanical &
Electrical Equipment, Piping, Valves & Accessories for the Sewage
Treatment Plant as per approved Hydraulic Calculations, Design and
Shop Drawings.
-

241
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

-
(A) ELECTROMECHANICAL EQUIPMENTS -
-
A.1 Raw Sewage Relift Pumps (Collection Sump) -
Providing and fiing dry motor submersible pumps of suitable rating,
with non-clog free flow open impeller, solid handling capacity of
minimum 46 mm suitable for operation on 415 volts ± 10% , 3 Phase,
50Hz, A.C supply, speed 1430 RPM of approved make including oil
chamber, guide wire for lifting & lowering of pump, M.S. galvanized
lifting chain, duck foot bend complete. The pump sets shall be
supplied with required accessories, valves, fittings, cables etc. & as per
specification.
-

No. of Pumps : 2 (1W + 1S) -


Capacity :12 m3/hour of each pump -
Head : 10-15 M -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 185,000.00 185,000
-
A.2 Raw Sewage Relift Pumps (Equalisation Tank) -
Providing and fiing dry motor submersible pumps of suitable rating,
with non-clog free flow open impeller, solid handling capacity of
minimum 46 mm suitable for operation on 415 volts ± 10% , 3 Phase,
50Hz, A.C supply, speed 1430 RPM of approved make including oil
chamber, guide wire for lifting & lowering of pump, M.S. galvanized
lifting chain, duck foot bend complete. The pump sets shall be
supplied with required accessories, valves, fittings, cables etc. & as per
specification.
-
No. of Pumps : 2 (1W + 1S) -
Capacity :10 m3/hour of each pump -
Head : 10-15 M -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 185,000.00 185,000

242
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

A.3 Air Blower -


Providing and fixing air Blowers of twin-lobe type (air cooled) for
continuous service with construction in cast iron casing, for oil-free air
delivery with anti-friction bearings alloy steel toughended shafts, duly
coupled with suitable drive for operation on 415 volts ±10%, 3 phase,50
Hz, A.C. supply complete with testing and commissioning etc.as
specified and as required.

-
No. of Pumps : 2 (1W + 1S) -
Capacity : 200m3/hour -
Head : 5-6 M -
Note:-1 set consists of 2 nos. of (1Working + 1Standby) Set 1.00 380,000.00 380,000
-
A.4 Air Diffuser -
Providing and fixing membrane diffusors in EPDM / High Grade Silicon
material (Coarse & Fine Bubble as per requirements) with connections
to air piping by threaded means, of tube/disc type as required as per
process requirements complete with testing and commissioning etc.as
specified and as required.
Lot 1.00 75,000.00 75,000
-
A.5 Sludge Return / Relift pump -
Providing and fixing centrifugal Sludge Return / Re-lift pumps for the
transfer of sludge from secondary clarifier with Cast Iron impeller and
cast steel shaft with mechanical seal, with TEFC induction motor of
class "F" insulation & efficiency class EFF-1, suitable for operation on
415 volts ±10%, 3 phase, 50 Hz, A.C. supply, 2900 RPM of approved
make complete in all respects and as per specification.
-
No. of Pumps : 2 (1W + 1S) -
Capacity : 5 m3/hour of each pump -
Head : 15-20 M -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 53,000.00 53,000

243
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

-
A.6 Sludge Loading / Disposal pump -
Providing and fixing Screw Type Sludge loading / Disposal pump in
cast iron body, hardened steel / SS single helical rotor and shaft, with
safety release valve, Non return valve and all necessary accessories
with TEFC induction motor of class "F" insulation & efficiency class EFF-1,
suitable for operation on 415 volts ±10%, 3 phase, 50 Hz, A.C. supply
complete in all respects and as per specification.

-
-
No. of Pumps : 2 (1W + 1S) -
Capacity : 2 m3/hour of each pump -
Head : 20-30 M -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 127,000.00 127,000
-
A.7 Filter Feed Pump -
Providing and fixing In-line vertical multistage centrifugal clear water
pump set of approved make with SS-304 casing, SS-304 impeller, SS-
316 shaft, CI base with CED coating, complete directly coupled with
TEFC induction motor of class "F" insulation & efficiency class EFF-1,
2900 RPM, suitable for operation on 415 volts ±10%, 3 phase, 50 Hz,
A.C. supply (with cartridge type mechanical seal), pressure gauges
with gunmetal isolation cocks, vibration elimination pads, etc.
mounted on a MS base frame bolted to cement concrete foundation
complete in all respects and as per specification.
-
-
No. of Pumps : 2 (1W + 1S) -
Capacity : 12 m3/hour of each pump -
Head : 25 - 30 M -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 73,000.00 73,000

244
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

-
A.8 Filter Backwash Pump -
Providing and fixing In-line vertical multistage centrifugal clear water
pump set of approved make with SS-304 casing, SS-304 impeller, SS-
316 shaft, CI base with CED coating, complete directly coupled with
TEFC induction motor of class "F" insulation & efficiency class EFF-1,
2900 RPM, suitable for operation on 415 volts ±10%, 3 phase, 50 Hz,
A.C. supply (with cartridge type mechanical seal), pressure gauges
with gunmetal isolation cocks, vibration elimination pads, etc.
mounted on a MS base frame bolted to cement concrete foundation
complete in all respects and as per specification.

-
-
No. of Pumps : 2 (1W + 1S) -
Capacity : 15 m3/hour of each pump -
Head : 30 M -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 96,000.00 96,000
-
A.9 Hydropneumatic Pumping System With Variable Frequency Drive
-
Supply, Installation, Testing and Commissioning of compact packaged
type skid mounted, self contained variable frequency drive
hydropneumatic system complete as required & as per specification
with the following:-
-
(i) In- line vertical multistage centrifugal clear water pump set with SS-
304 casing, SS-304 impeller with SS-316 shaft ,CI base with CED coating
complete directly coupled with TEFC induction motor of class "F"
insulation & efficiency class EFF-1, 2900rpm, suitable for opertion on
415 Volts ±10%, 3 phase, 50 Hz A.C. supply complete.

245
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
(ii) The entire system shall be mounted on a common base frame i/c
common suction and common delivery of G.I heavy class pipe
headers with flanges, interconnecting piping with all required Conrol
Valves, Non-return valves, pressure guage with isolation cock etc. and
all requried accessories.
-
(iii) Pressure vessel of non corrosive FRP composite construction lined
with NSF and/or FDA listed material, like high density polyethylene
with fully replaceable polyurethane. Air cell burst pressure of
minimum of 5 times the vessel operating pressure and cycle tested for
80,000 cycles with charging connections to dischage pipe line with
necessary flanges, gaskets, isolating valve, nuts/ bolts etc. with
suitable foundation boits & other accessories, complete.
-
(iv) Panel mounted microprocessor multi pump contoller with large
graphical display and Flying variable frequency drive (VFD) mounted
inside a panel complete with pressure sensor transmitter. The graphical
display capable to show number of pumps running & also
communicate with other controllers following with open protocol
through RS485 port. System should be capable to compensate for
frictional losses at lower flows. All alarms should be displayed in the
controller. The panel should also have provision for manual /
automatic alternate (cyclic) operation of pumps, ON/OFF
switch,complete.
-
(v) Necessary foundationing bolts, vibration elimination pads and
other accessories complete as required. -
Flushing Water Supply to Terminal -bdg -
Duty of each pump suitable for:- -
No. of Pumps : 2 nos. (1 W + 1 S) -
3
Capacity : 10 m /Hour of Each Pump -
Head : 65 Meters -
Air Vessel : 1 No of Min. 100 Liters Cap. -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 656,000.00 656,000
-

246
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Garden hydrant Pump
-
Duty of each pump suitable for:-
-
No. of Pumps : 2 nos. (1 W + 1 S)
-
Capacity : 5 m 3/Hour of Each Pump
-
Head : 45 Meters
-
Air Vessel : 1 No of Min. 100 Liters Cap.
-
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby)
Set 1.00 515,000.00 515,000
-
A.10 Dual Media Filter -
Providing and fixing vertical Dual Media Pressure Filter (comprising of
minimum 300mm bed depth of Anthracite and support media and
minimum Height on Straight 1500mm) fabricated from high
performance M.S plate of minimum 10mm thick for shell & 12mm thick
for dished ends,(Quality of Steel as per IS:2062 Grade B, thickness as
per ASME Section 8),Tested to 5.0 Kg/cm2 , internally treated with coal-
tar epoxy / FRP lined, air scouring, collection system initial charge of
media, M.S face piping with necessary flanges, gaskets, isolating
valves, accessories,nuts & bolts, external painting with 2 coats of red
oxide primer and enamel paint etc. with suitable foundation boits &
other accessories, mounting frame, complete with testing and
commissioning etc.as required & as specified.

3
Discharge : 15 m /Hour Each
-
2
Filtration Rate : 17500 lit./m /h
-
Suggested dia app. : 1.6 m
Each 1.00 179,000.00 179,000

247
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
A.11 Activated Carbon Filter -
Providing and Fixing of Activated carbon filter with minimum 300mm
bed depth of Anthracite and support media and maximum Height on
Straight 1500mm, fabricated from high performance M.S plate,Tested
to 5Kg/cm2, internally treated with coal-tar epoxy / FRP Lined,
complete with air scouring, collection system complete with initial
charge of media, M.S face piping, valves, accessories, external
painting with 2 coats of red oxide primer and enamel paints as per
Manufacturer's standard and testing & commissioning complete.

3
Discharge : 15 m /Hour Each -
Filtration Rate : 17500 lit./m 2/h -
Suggested dia app. : 1.6 m Each 1.00 179,000.00 179,000
-
A.12 Dosing System at Clarified water tank and Treated water tank -
Providing and fixing chemical dozing system of approved make with
all accessories, suitable to doze chemical solution upto 1 ppm doze
(of Sodium Hypo-chloride solution) to a filtered water flow of 50,000
lph. against a pressure of 1.5 kg/cm2 complete with FRP moulded
solution holding tank of min. 100 litre with all standard accessories &
structural arrangement including suitable foundation bolts & other
accessories etc.complete as required and as specified.

-
At clarified water tank -
System : Metering Type -
Capacity : 0-50 LPH -
Feed solution: Hypochlorite/pH Dosing / polyelectrolyte -
Conc. of solution : 0.1 -
MOC of tank & Capacity: FRP - 100 Liters -
Nos. of pumps : 2 (1w+1s) -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 32,000.00 32,000
-

248
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
At treated water tank -
System : Metering Type -
Capacity : 0-50 LPH -
Feed solution: Hypochlorite/pH Dosing / polyelectrolyte -
Conc. of solution : 0.1 -
MOC of tank & Capacity: FRP - 100 Liters -
Nos. of pumps : 2 (1w+1s) -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 32,000.00 32,000

A.13 Drainage Sump Pumps for Plant Room Drainage, Backwash waster
water sump pump -
Providing and fixing compact dry motor submersible pumps of
suitable rating, with non-clog free flow open impeller, handling
capacity of 28mm suitable for operation on 415 volts +10% , 3 Phase,
50Hz, A.C supply, speed 2900 RPM of approved make including oil
chamber, guide wire for lifting & lowering of pump, M.S. galvanized
lifting chain, duck foot bend complete. The pump sets shall be
supplied with required accessories & as per specification with all
accessories and control system.
-

Plant room drainage sump pump -


No. of Pumps : 2 (1W + 1S) -
Discharge: 15 m3/hr -
Total Head : 15 metre -
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby) Set 1.00 191,000.00 191,000
-
Back wash waste water sump pump
-
No. of Pumps : 2 (1W + 1S)
-
Discharge: 15 m3/hr
-
Total Head : 15 metre
-
Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby)
Set 1.00 191,000.00 191,000

249
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
A.14 Sludge Handling Mechanism (Centrifuge)
-
Providing and fixing of sludge handling arrangement (Centrifuge)
solid bowl type for upto 100 deg. Celsius temperature to be placed on
a platform above the ground with arrangement for sludge feed to
centrifuge from screw type sludge pumps at a distance as required
with watering and flushing arrangement. Effluent from Centrifuge to
be connected to equilization tank and the entire equipment
mounted on MS base frame bolted to cement concrete foundation
complete with testing & commissioning as required and as specified.

-
Nos. : 1 -
Capacity : 2 m3/ hr Each 1.00 58,000.00 58,000
-
A.15 UV for Supply to Flushing Line -
-
Providing and installation of Online UV system with IP-54 rated
cabinet housing in sheet steel wth electrophoretic dipcoat priming
and powder coated finish, and SS-316 treatment chamber material,
with electronic ballast type,suitable for operation on 230 volts , 50Hz,
for installation on the pressurized discharge line, suitable for tertiary
treated wastewater of min. transmissivity of 65% complete with testing
& commissioning as required and as specified.
-

Nos.: 1 -
Capacity : 35000LPH Each 1.00 560,000.00 560,000

A.16 Sludge Trolley -


Fabrication and supply of sludge trolley in Galvanized Steel with min.
Dimensions of 950 mm x 600mm x 500 mm depth (min. sheet thickness
2.0 mm) with handle and wheel barrow for transport of sludge
complete as per requirements as specified.
Each 1.00 35,000.00 35,000

250
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

-
A.17 Mechanical Scrapper (Clarifier mechanism)
-
Providing and fixing of central driven clarifier mechanism of minimum
4.5m dia to be installed in RCC tank consist of fixed type full span
structural bridge (Lattice Structure) up to the centre of the clarifier
having 750mm width platform & 1000 mm high handrails, mechanical
scraper having two scraper arms with neoprene squeegees duly
driven by suitable HP high torque, Class F insulation motor operates on
230V ± 10% single phase 50 HZ HC supply and gearbox, Inlet PP tank of
suitable capacity duly hang with the bridge, Painting with Epoxy
Painted (To wetted MS part), and enamel paint (to remaining MS part)
etc. complete as per requirements.
Each 1.00 570,000.00 570,000
-
A.18 Bar Screens
-
Providing and fixing manually cleaned Bar Screens, to remove coarse
and fine material in the waste water made up of FRP complete as
required including handle for lifting.
-
Coarse Screen (for 0.6 m/s inlet velocity and 0.9 m/s outlet velocity,
with 12mm c/c spacing of bars.
Each 1.00 20,000.00 20,000
Fine Screen (for 0.6 m/s inlet velocity and 0.9 m/s outlet velocity, with
6mm c/c spacing of bars.
Each 1.00 16,000.00 16,000
-
A.19 BIO- Media -
Providing suspended/floating bio-media(moving bed bio-
media/MBBR media) with PVC/PP material of construction , UV-
stabilized, with max. operating temperature of 55OC, complete as per
requirement. -
Media Required : 20 cu.m -
1 Lot: 20 cum Lot 1.00 65,000.00 65,000

251
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
(B) PIPING AND VALVES ACCESSORIES
-
B.1 Provding and fixing heavy duty G.I. pipe confiming to IS. 1239 upto 150
mm and IS 3589 for dia 200 mm and above with reducers, tees,
flanges, elbow, crosses, union etc. and fixing the pipes on wall /
ceiling / beam / floor including Clamping/Supporting the same as per
the site requirement and shall be duly painted with two coats of
approved quality synthetic enamel paint & shade over a readymix
primer coat complete as required & as per specifications. (For all clear
water pumps / Air piping.
-
32 mm dia

Metre 10.00 520.00 5,200


40 mm dia

Metre 20.00 655.00 13,100


50 mm dia

Metre 35.00 855.00 29,925


65 mm dia

Metre 40.00 1,060.00 42,400


80 mm dia

Metre 60.00 1,305.00 78,300


100 mm dia

Metre 120.00 1,765.00 211,800


150 mm dia

Metre 100.00 2,530.00 253,000


200 mm dia

Metre 150.00 3,760.00 564,000


-

252
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
B.2 Providing and fixing uPVC pipes (I.S:4985-2000) Class - 3 (Min. 6
2
Kg/cm ) with bends, junctions, elbows, tees, offsets etc. jointing with
screwed joints, cutting holes in walls, fixing the pipes on wall / ceiling
/ beam / floor including Clamping/Supporting the same as per the site
requirement wherever required and making good complete as
required & as per specification (For Effluent / Sludge / Air Piping)
-
20 mm dia Metre 55.00
25.00 1,375
25mm dia Metre 60.00
40.00 2,400
32 mm dia Metre 85.00
80.00 6,800
40 mm dia Metre 100.00
120.00 12,000
50 mm dia Metre 145.00
80.00 11,600
63 mm dia Metre 105.00
65.00 6,825
75 mm dia Metre 140.00
25.00 3,500
90mm dia Metre 200.00
35.00 7,000
110 mm dia Metre 290.00
10.00 2,900
-
B.3 Providing & fixing butterfly valve of rating PN 1.6, wafer type, in cast
iron body with Ductile Iron disc, EPDM seal, SS single piece shaft,
conforming to IS-13095 of the following sizes complete with cast iron
hand level companion flanges, bolts, nuts, washers & inserted rubber
gaskets, as required and as specified.
-

65 mm dia Each 8.00 7,000.00 56,000


80 mm dia Each 16.00 7,900.00 126,400
100 mm dia Each 20.00 9,100.00 182,000
150 mm dia Each 10.00 12,500.00 125,000
-

253
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
B.4 Providing and fixing forged brass ball valve having stainless steel /
brass ball tested to 20 kg/cm2 complete as required and as specified.
-

32 mm dia
Each 1.00 925.00 925
40 mm dia Each 1,360.00
3.00 4,080
50 mm dia Each 1,975.00
7.00 13,825

-
B.5 Providing & fixing non return valve Dual Plate type, conforming to API-
594 with C.I. body, SS Disc, SS stem, EPDM seal, complete with
companion flanges, bolts, nuts, washers & inserted rubber gasket
complete as required and as specified. -
-
65 mm dia Each 2.00 8,355.00 16,710
80 mm dia Each 8.00 9,295.00 74,360
100 mm dia Each 5.00 12,920.00 64,600

-
B.6 DSR NO Providing and fixing Cast iron pipes (I.S:3989 / LA Class) with bends,
18.27 junctions, elbows, tees, offsets etc. jointing with chemical sealant
cutting holes in walls, fixing the pipes on wall / ceiling / beam / floor
including Clamping/Supporting the same as per the site requirement
wherever required and making good complete as required & as per
specification (For Effluent / Sludge Piping)
-
-
75 mm dia Metre 810.55
15.00 12,158
150 mm dia Metre 1,616.75
8.00 12,934
-

254
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
(C) CONSUMABLES FOR OPERATION AND MAINTENANCE
-
-
C.1 Supply & Consumption of Consumables, solutions, chemicals, etc. for
STP operation and maintenance including sucessful operations for 2
weeks upto commissioning stage / certification of STP.
Lot 1.00 50,000.00 50,000
-
(D) ELECTRICAL SYSTEM -
-
D.1 Design, manufacture, supply, installation, testing and commissioning
of the STP panel, front operated, cubicle construction, Floor mounted
type, fabricated out of 2mm thick CRCA Sheet, Compartmentalized
with hinged lockable doors, dust and vermin proof, Powder coated of
approved shade, Cable alley, inter-connections, having Switch gear
and accessories mounting, internal wiring, earth terminals, Top/ Bottom
cable entry, numberings etc. suitable for operation of 415 volts, 3
phase, 4 wire, 50 Hz, AC Supply with enclosure protection class IP 54
complete as required and as specified.
Lot 1.00 415,000.00 415,000
-
D.2 Supply of sizes of 1.1KV grade XLPE insulated and PVC sheathed
aluminium conductor armoured stranded power cables conforming
to IS 7098 Part-1 as ammended upto date and as specified.
-

D.2.1 (2 core 4 Sq.mm) Metre 60.00 96.00 5,760


D.2.2 (2 core 10 Sq.mm) Metre 70.00 138.00 9,660
D.2.3 (3 core 4 Sq.mm) Metre 200.00 108.00 21,600
D.2.4 (3 core 25 Sq.mm) Metre 300.00 218.00 65,400
D.2.5 (4 core 10 Sq.mm) Metre 150.00 190.00 28,500
D.2.6 (4 core 25 Sq.mm) Metre 60.00 278.00 16,680
-

255
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
D.3 Supplying and making of cable end termination with brass single
compression gland and Al. lug for following size of PVC insulated and
sheathed armoured cables of 1.1 K.V. aluminum conductor as
required. -

D.3.1 (2 core 4 Sq.mm) Metre 6.00 145.00 870


D.3.2 (2 core 10 Sq.mm) Metre 5.00 147.00 735
D.3.3 (3 core 4 Sq.mm) Metre 10.00 147.00 1,470
D.3.4 (3 core 25 Sq.mm) Metre 20.00 290.00 5,800
D.3.5 (4 core 10 Sq.mm) Metre 10.00 213.00 2,130
D.3.6 (4 core 25 Sq.mm) Metre 6.00 313.00 1,878
-
D.4 Laying and fixing of one number XLPE /PVC insulated and PVC
sheathed power of 1.1 KV grade of following sizes on surface or
existing cable tray complete as required.
-

Size not exceeding 25 Sq.mm.


Metre 800.00 66.00 52,800
-
D.5 ELECTRIC Earthing with GI earth plate of 600mm x 600mm x 6mm thick, including
AL DSR accessories and providing masonary enclosure including MS cover
5.3 plate having locking arrangement and watering pipe etc. with
charcoal and salt complete as required & as specified.
Each 2.00 3,557.00 7,114
-
D.6 ELECTRIC Providing and Fixing 25 mm x 5 mm G.I. Strip in 40 mm dia. G.I. pipe
AL DSR from earth electrode complete as required.
5.11
Metre 14.00 421.00 5,894
-
D.7 ELECTRIC Providing and Fixing 25 mm x 5 mm G.I. Strip on surface or in recess for
AL DSR earth connection as per specifications complete as required.
5.15 Metre 70.00 134.00 9,380

256
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

-
D.8 ELECTRIC Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop
AL DSR earthing as required.
5.7
Metre 300.00 27.00 8,100

-
D9 ELECTRIC Fabrication and installation of perforated MS cable tray including
AL DSR horizontal and vertical bends, reducers, tees, cross-members and
4.1 other accessories as required duly suspended from the ceiling with MS
Suspenders and including painting with black synthetic paint as
required.
-

-
D.9.1 50 mm. (W)x50 mm.(D)x1.6 mm (T)
Metre 20.00 405.00 8,100
D.9.2 100 mm. (W)x50 mm.(D)x1.6 mm (T)
Metre 25.00 461.00 11,525
D.9.3 150 mm. (W)x50 mm.(D)x1.6 mm (T)
Metre 135.00 520.00 70,200
D.9.4 300 mm. (W)x 50 mm.(D)x1.6 mm (T)
Metre 70.00 789.00 55,230
D.9.5 600 mm. (W)x 50 mm.(D)x2.0 mm (T)
Metre 30.00 1,386.00 41,580

-
D.10 Providing electric insulated rubber mat non-skid type with grooved top
90 cm wide & 12 mm thk as per IS : 5424 as required suitable for 1100 3.00 1,200.00 3,600
volts. RM

257
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
(E) INSTRUMENTATION EQUIPMENTS &
INSTRUMENTATION DETAILS/
LABORATORY APPARATUS -
-
E.1 Supply, Installation, Testing and Commissioning of following
Instrumentation Equipments -
Electromagnetic Flow meter size: 300 mm,
Flow range: 0-500 m3 / hr,
Linear Material: Elastometer,
Electrode Material: SS Transmitter Mounting,
Remote cable length: 10 m,
Display: 3 Line Backlit with programming keypad Output: 4-20 mA
(Model: "MFF30134110A105ER140111X" or Equivalent)
-
-
Electromagnetic Flow meter size: 150 mm,
Flow range: 0-115 m3 / hr,
Linear Material: Elastometer,
Electrode Material: SS Transmitter Mounting,
Remote cable length: 10 m,
Display: 3 Line with programming keypad
Output: 4-20 mA
Range: 10 m
Mounting: Integral (Tank Top)
(Model: "MFE15134110A105ER140211X" or Equivalent)
-
-
Submersible Electrode DO Analyser (Model: AX480/10001+9408/600 or
Equivalent) -
-
Ultrasonic Level Transmitter: Range 10 m, mounting: Integral (Tank Top)
(Model No. U80 - 10 or Equivalent) Set 1.00 791,775.00 791,775
-

258
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
E.2 Supply, Installation, Testing and Commissioning of Laboratory
Apparatus including Glassware lab Equipments (As per Details below)

-
(i) Supply of following Laboratory Apparatus
-
1 Flow Meter: As per approved Make - 3Nos.
-
(a)Type: Bulk Discharge / Electro Magnetic Type
-
(b)Capacity: 0 to 150%of Peak Discharge
-
(c)Make: As per approved List
-
2 PH Meter (Digital with Electrodes): pH 1.0 to 14.0 - 1No.
-
3 Conductivity Meter: As per approved List -1No.
-
4 DO (Dissolved Oxygen) Meter, E-Merck / EU Tech: 0 – 20 mg/l - 1No.
-
5 SS/Hardness Testing Apparatus: As per approved List -1No.
-
6 Energy Meter: As per approved List -1No. -
7 Pressure Gauges: As per approved List -1Lot -
8 Level Gauges: As per approved List -5Nos. -
9 TDS Meter (Digital, Microprocessor based): Hand-held -1 No. -
10 Electronic Balance: As per approved List - 1No.
-
11 Hot Air Oven (Upto 250oC): 445 x 445 x 445 mm Aluminum Chamber
with Digital Control -1No.
-
12 Muffle Furnace ( RT to 12000C): 150 x 150 x 350 mm -1No. -
13 Heating Mantle ( 1L ): RT to 1200C -1No. -
14 Water Distillation Apparatus (Stainless Steel): Capacity 4 L / Hr. -1No. -
15 Hot Plate: 2 ft. x 1.5 ft. -1No. -
16 Top Loading Electronic balance with all accessories.: Capacity 200 g,
Accuracy 0.01 mg. -1No. -
17 Magnetic Stirrer (w/ magnet) : 1 ltr. cap.-1No.
-

259
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
18 COD Heating Mantle: 6 Nos. COD Flasks -6No.
-
19 Jar Testing Apparatus: Capacity: 1Ltr., with six stirrer -1No.
-
20 BOD Incubator: 580 x 580 x 970,SS chamber, 5-500C, Accuracy:0.50C,
Digital Controller -1No. -
21 0.25 HP, Double stage, 50Lit/Hr, NRV & Pressure Gauge -1No. -
(ii) Supply of following Glassware lab equipments required for laboratory
-
1 Beakers: 100 ml: 4 Nos.
: 250 ml.: 4 Nos.
: 500 ml.: 2 Nos.
-
2 Reagent Bottles: 500 ml.: 6 Nos.
: 1000 ml.: 2 Nos.
-
3 Burettes: 25 ml x 1/10 ml.: 2 Nos.
: 50 ml x 1/10 ml: 2 Nos. -
4 Graduated Cylinders: 50 ml x 1/10 ml.: 1Nos.
: 100 ml x 1/10 ml.: 2 Nos.
: 250 ml x 1/10 ml.: 2 Nos.
: 1000 mlx1/10 ml.: 2 Nos.
-
5 Flasks conical: 250 ml.: 6 Nos.
-
6 Dish Evaporating: 80 x 45: 10 Nos.
-
7 Imhoff cones: Size : 439 mm: 3 Nos.
-
8 COD Flasks, size 24/29: 250 ml.: 12 Nos.
-
9 Flasks Volumetric : 100 ml.: 2 Nos.
: 250 ml.: 2 Nos.
: 500 ml.: 2 Nos.
-
10 Flasks Boiling (Flat Bottom): 1000 ml.: 2 Nos.
-
11 Funnels : 100 ml.: 2 Nos.
-

260
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
12 Pipettes: 1 ml x 1/10 ml.: 2 Nos.
: 5 ml x 1/10 ml.: 2 Nos.
: 10 ml x 1/10 ml.: 2 Nos.
-
13 Bulb Pipette: 10 ml.: 2 Nos.
: 25 ml.: 2 Nos.
-
14 Dessicator : 150 x 15 mm: 1 No.
-
15 Test Tubes: 10 x 75 mm: 12 Nos. -
16 Wash Bottles Plastic : 500 ml.: 2 Nos. -
17 Glass Rods: : 2 Nos. -
18 Pipette Bulb: : 2 Nos.
-
19 Spatula : 6”: 1 No.
: 8”: 1 No.
-
20 Tong: 6”: 1 No.
: 8”: 1 No. -
21 Burette Stand: : 2 Nos.
-
22 COD Condenser, size 24/29 : : 6 Nos.
-
23 Pipette Stand: : 1 No.
-
24 Thermometer: 0-50oC: 1 No.
-
25 Whatman 40/42 Filters: : Lot
-
26 pH Paper: Mixed Range: Lot
-
27 Reagent Bottles Amber: 500 ml.: 2 Nos.
-
28 Glass Rods: 1 Kg: 1 No.
-
29 Separating Funnel : 250 ml.: 2 Nos. Set 1.00 500,000.00 500,000

SUB - TOTAL (SECTION 1.1) 1 x 500 m3/Day


8,604,898

261
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
1.2 Manning, Operating & Maintaining the Sewage Treatment Plant (during
defects liability period) complete in all respects, including all technical/non-
technical manpower, consumables and disposal of treated effluent/solid
sludge as per requirements, and its all comonents works as a whole and the
various assets generated thereon under this contract, including cost of
collection , analysis, reporting ,monitoring and maintaining record of samples
from the raw sewage daily collected at least for one time a day from the
entry and exit of the STP including required staff and consumables ,
chemicals like chlorine, polymer, salts etc., complete. as per proposed
details by Vendor in approved format and training to Client representatives
as per the guidelines/ requirements of the Client.

1.2.1 Total Cost for Operation & Maintenance for the first 12 months after
commissioning - Year 1
Job 1.00 1,100,000.00 1,100,000
1.2.2 Total Cost for Operation & Maintenance for the Subsequent 12 months after
commissioning - Year 2
Job 1.00 1,300,000.00 1,300,000

SUB - TOTAL (SECTION 1.2)


2,400,000
SUB - TOTAL (SECTION 1.1)
8,604,898
TOTAL
11,004,898

LESS 5% FOR UPRNN WORKING (550,245)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 10,454,653

262
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATE OF WATER BODY WITH FOUNTAINS NEAR CRICKET GROUND

SUBHE SUBHEAD OF WORKS ESTIMATED


AD NO AMOUNT IN INR

A Pumps, Filtration & Related Accessories 1,323,600

B Piping & Valves 683,900

C Pool Fittings & Accessories 721,000

D Miscellaneous 46,000

TOTAL 2,774,500

LESS 5% FOR UPRNN WORKING (138,725)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 2,635,775

263
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DESCRIPTION
S.N. QTY. RATE AMOUNT

IX C. WATER BODY WITH FOUNTAINS NEAR TENNIS COURT

A. PUMPS, FILTRATION & RELATED EQUIPMENT

1 Recirculation Pumps

Providing and fixing self priming pump with built-in strainer, ABS body, with
Noriyl impeller complete in all respect to deliver the following duty
parameters.

Discharge per Pump : 30 m3 /hr


App. Head : 15m
Nos. : 3 (2 working + 1Stand By )
Rating of pump: 2.2 Kw ( Approx.)
Each 3.00 65,000.00 195,000
-
2 Pressure Sand Filter
-
Supply, Installation Testing and Commissioning of vertical commercial Sand
Filter of 1100 mm Ø. Sand filter technical data: -
Manually Operated
-
i) Working Pressure : 2.5 Kgs/ Sqcm.
-
ii) Rate of flow per Filter: 30 m3/hr
-
iii) App Dia: 1100 mm
Each 2.00 170,000.00 340,000

3 Providing pool filter sand and gravel in sand filter as a filtration media to
purify pool water.

264
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
•Sand size: 0.4 - 0.8 mm.

•Gravel size: 1.0 - 2.0 mm.

•Free of silts, fines and dusts.

•Physical Characteristics.

•Color: Light tan.

•Bulk Density: 100 lbs./cu. ft.

•Specific Gravity: 2.65+

•Effective Size: .40 – .55 mm

•Uniformity Coefficient: < 1.7


kgs 1,800.00 15.00 27,000

4 Automatic Chemical Dozing System


-
Providing and fixing automatic chemical dozing system consisting of
electronic dozing pump, suitable to doze chemical solution as per
requirement with a dosing capacity of (0-6 lph) for dosing of app. 1.4 ml of
chemical to a flow of water of 30,000 lph. against a pressure of 5 bar.
Each 2.00 26,000.00 52,000
-
5 Providing and fixing semi transparent polyethylene Dosing tank with external
scale, so that levels can be checked easily, Tank capacity: 100 Ltrs.
Minimum.
Each 2.00 5,000.00 10,000

6 Providing and fixing agitators for easy installation in the tanks, with steering
grip in Bakelite. Agitator rod and propeller arms in PVC material, The length
of stirring rod shall be 600mm Approx.
Each 2.00 9,800.00 19,600

7 Sump Pumps for Lifting Water from Pump Room


-
-

265
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing compact monoblock submersible pumps for suitable
rating, with non-clog free flow open impeller, minimum solid handling
capacity of 46mm suitable for operation on 415 volts + 5% -15%, 50 C/s A.C
3 phase supply, speed 960/1440R&M including guide wire for lifting &
lowering of pump, M.S. galvanized lifting chain, duck foot bend with following
specifications:
-
The above pump sets must be supplied complete with following accessories.

-
-
a) Complete piping 100mm dia common delivery upto 5m as per enclosed
tentative layout. (The pipe should be preferably CI LA/heavy duty G.I) -- 1
Set -
-
b) 80mm dia Butterfly valve.-- 2 Nos -
-
c) 80 mm dia non return valve.-- 2 Nos
-
-
d) Necessary cables from pump set to control panel (position of panel marked
in enclosed layout in plant room).-- 1 Set
-
-
e) Electrical switch panel having all necessary accessories & safety devices of
standard specifications. (Panels with sump pumps near each sump as per
site conditions). --1 No.
-
-
f) Automatic built-up water level controller with necessary length of cable upto
control panel. -
-
Motor rating - 1.1KW -
Discharge - max. 12 Cu.m/hr. -
Total head - 12 m -
Make - "KSB" -
Model - Ama Porter 503.SE or equivalent. -
(Complete set as above with 2 nos. pumps) Set 1.00 165,000.00 165,000
-
8 Motor Control Panel
-

266
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing and Commissioning of Motor Control Center for
Water Body. The MCC Shall be Cubical Type, constructed from 14/16 SWG
CRCA Sheet Steel , suitable for indoor installation. Dust/Vermin proof floor
mounted. Panel should be powder coated
-
-
INCOMING
-
1 Incoming feeder shall be of suitable rating A, 36 KA, TP, MCCB, Volt Meter
Amp Meter, CTs, Energy meter, selector switch, phase indicating lamp etc.

-
-
OUTGOING
-
2.2 kW Water Re-circulation Pump- 3 Nos MCB, MPCB, Star - delta starters
& ON/OFF push buttons with power and control cable including cable
termination, earthing etc.
-
-
1.5 kW Water Feature Pump- 3 Nos MCB, MPCB, Star - delta starters &
ON/OFF push buttons with power and control cable including cable
termination, earthing etc.
-
-
1 No 4 pole MCB feeder, indicating lamp etc: water body in side lighting
distribution panel
-
-
1 No 4 pole MCB feeder, indicating lamp etc: 2 Nos. Dosing Pump

Set 1.00 310,000.00 310,000

267
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9 Providing and fixing heavy duty copper armored cables 1.1 KVA grade
including necessary support clamps at ceiling level and connection legs
complete in all respects.
-
-
a) Power cable 3 core 2.5 Sq.mm
Metre 80.00 680.00 54,400
-
b) Power cable 4 core 2.5 Sq.mm
Metre 65.00 350.00 22,750
-
c) Power cable 2 core 2.5 Sq.mm
Metre 250.00 200.00 50,000
-
10 Supply, laying and termination of earthing to main electrical panel, water
circulation pumps, lighting distribution Boards, dosing pump etc.12 SWG Cu
Wire for pumps, distribution Boards.
Metre 40.00 310.00 12,400
-
11 Providing and fixing M.S. slotted cable tray supported from ceiling at
intervals of 60cms on both ends including cable clips with nuts and bolts
welding of support rods with ceiling inserts or through dash fasteners cutting
and making good complete.
-
-
a) 300mm wide
Metre 50.00 789.00 39,450
b) 150mm wide
Metre 50.00 520.00 26,000
-
Total C/o to summary
1,323,600

268
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
B. PIPING & VALVES

1 Providing and fixing UPVC pipes class 10 kgf/cm2 as per I.S:4985-2000


including all fittings with or without access bends junctions, offsets, PVC pipe
clips/ holders etc. and jointing with ruber rings and cement solvent complete
provision for making flange joints with Stubend ,wherever required, as per
manufacturer's specifications with excavation, refilling and disposal of
surplus earth, including cutting holes in walls and floors, wherever required
and making good the same, complete as directed by the Engineers-In-
charge and as per approved specifications.
-
-
a) 63mm Nominal Outside dia
Metre 50.00 255.00 12,750
-
b) 75mm Nominal Outside dia
Metre 115.00 335.00 38,525
-
c) 90mm Nominal Outside dia
Metre 125.00 440.00 55,000

-
d) 110mm Nominal Outside dia
Metre 375.00 625.00 234,375

-
e) 160mm Nominal Outside dia
Metre 15.00 1,240.00 18,600

-
f) 200mm Nominal Outside dia 1,955.00
Metre 10.00 19,550

-
2 Providing and fixing of uPVC, anti corrosive, butterfly valves of 10 Kg / sqcm.
pressure, flanged end type, following ASTM standards, including additional
uPVC flanges and adapter on receiving pipes with nuts, bolts and gasket
insertion as required.
-
-
a) 63 mm O.D. Each 11.00 9,500.00 104,500

269
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
b) 75 mm O.D. Each 1.00 9,500.00 9,500
-
c) 90 mm O.D. Each 4.00 12,000.00 48,000
-
d) 110 mm O.D. Each 7.00 13,000.00 91,000
-
e) 160 mm O.D. Each 1.00 20,000.00 20,000

f) 200 mm O.D. Each R.O.

3 Providing and fixing of double flanged horizontal type, anti corrosive, uPVC
10 Kg / sqcm. pressure, flanged end type, following ASTM standards,
including additional uPVC flanges and adapter on receiving pipes with nuts,
bolts and gasket insertion as required.
-
-
a) 90mm O.D. Each 3.00 6,200.00 18,600
-
4 Supplying and fixing in position uPVC Puddles Sleeve complete approved
make.

a) 63mm
Each 4.00 700.00 2,800
-
b) 75mm Each 1.00 1,400.00 1,400
-
c) 90mm Each 4.00 1,700.00 6,800
-
d) 110mm Each 1.00 2,500.00 2,500

Total C/o to summary


683,900
-
C. POOL FITTINGS & ACCESSORIES
--
1 Inlet Nozzles -
ABS side nozzle to glue into 50 mm dia uPVC pipe 5-6 Kg/cm2 & to fit on
concrete surface .Each Fountain Height: 3-4 m with cascade type feature.
Each 9.00 10,000.00 90,000
-

270
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2 Supply installation, testing and Commissioning of water Submersible Pump
of following ratings:
-
•Water flow rate: 20 m3 / hr
-
•System head: 12 mtr -
•Rating of pump: 1.5 Kw ( Approx.) Each 3.00 50,000.00 150,000
-
3 Providing and fixing main drain for grilles of size: 300 mm X 300 mm.
-
•Main drain grille material of construction: Stainless Steel SS-316 grade.
-
•Each drain grille water flow rate: @ 30 m3/hr. Each 4.00 17,000.00 68,000
-
4 Providing and fixing fresh water floor inlet in the water body -
•Floor inlet material of construction: ABS, bushing white in color. -
•Floor inlet dispersion of fresh water in the pool: 360° -
•Maximum flow rate of each floor inlet: Adjustable, 5.0 m³/hr. -
•Size: Internal Ø 50 mm & 2“ slip incl. flange, gaskets & stainless steel
screws, resistant against pool chemicals. Each 20.00 980.00 19,600
-
4 Vacuum Point type: Concrete Suction Nozzle-threaded Each 4.00 500.00 2,000
-
5 Providing and fixing Wall Conduit for Vacuum Point. -
Material of construction: ABS, -
Size: 50 mm Ø, threaded. Each 4.00 1,600.00 6,400
-
6 Providing and fixing Skimmer of Size: 63 mm Dia.
-
Material of construction: ABS,
Each 10.00 7,000.00 70,000
-
7 Under Water Lights -
-

271
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing of 12 Volts under water Stainless Steel SS 316 body
LED Lights, warm white made of heat resistance material wall mounted
made of unalterable plastic with S.S screws and gaskets supplied with all
necessary cables and conduits including suitable transformers for 220 V to
12 V complete in all respects as per approval of
samples/Catalogues.Comprises of conduit hose of suitable length for above
said wires / cable & deck box -ction box in ABS material in white.
--
a) 12 Watts
Each 9.00 35,000.00 315,000

Total C/o to summary


721,000

D. MISCELLANEOUS

1 Constructing masonry chamber 450x450x600mm inside with 75 class


designation brick work in cement mortar 1:5 (1 cement: 5 coarse sand) for
valves upto 65mm dia. with water tight C.I. cover and frame of 450x450mm
size (inside) with weight of cover to be not less than 10 Kg and frame to be
not less than 4 Kg as per standard design,necessary excavation, back filling
and disposal of surplus earth as per instructions, foundation concrete 1:5:10
(1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size) and
inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) finished
with a floating coat of neat cement complete as per standard design.
Each 2.00 15,000.00 30,000
-
2 Providing and fixing M.S structural work fabricated from standard sections
e.g. M.S. rounds, angles, channels, plates including cutting to size, welding,
drilling with concrete drilling bits and fixing dash fasteners in RCC structural
members as directed by Engineer-in-charge including cutting and making
good the walls, ceilings and floors (for all types of pipe supports, clamps,
etc.) complete, as directed by the Engineer in charge.
Kg. 200.00 80.00 16,000
Total C/o to summary
46,000

272
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

3 GRAND SUMMARY OF CIVIL WORKS FOR PLUMBING & FIRE FIGHTING

S.NO HEAD ESTIMATED


AMOUNT IN INR

CIVIL WORKS FOR INTERNAL FIRE FIGHTING ALL BUILDINGS, See Sl. No. SH-01 (Rs. 37500 + 37500 + 30000 +
3.01 150,000
45000)

CIVIL WORKS FOR EXTERNAL FIRE FIGHTING


3.02 256,466

TOTAL COST CARRIED OVER TO ABSTRACT


406,466

LESS 5% FOR UPRNN WORKING (20,323)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 386,142

273
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATED COST OF PLUMBING & FIRE FIGHTING SERVICES

S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

1.1 Providing & fixing M.S. structural work fabricated from standard section e.g. M.S
rounds bar, angles, channels, plates including cutting to size,drilling,welding fixing
and welding to insert plates in RCC structural members as recommended size of
fasteners to RCC slab as directed by engineer-in-charge including cutting and
making good the walls, ceilings and floors (for pipe structural supports, U clamps
etc.)

Kg 500.00 75.00 37,500

TOTAL C/O TO SUMMARY

37,500

ESTIMATED COST OF PLUMBING & FIRE FIGHTING SERVICES


HOSTEL BLOCK

SH -01 CIVIL WORKS FOR FIRE PROTECTION SYSTEM (NON-DSR Items)

1.1 Providing & fixing M.S. structural work fabricated from standard section e.g. M.S
rounds bar, angles, channels, plates including cutting to size,drilling,welding fixing
and welding to insert plates in RCC structural members as recommended size of
fasteners to RCC slab as directed by engineer-in-charge including cutting and
making good the walls, ceilings and floors (for pipe structural supports, U clamps
etc.)
Kg 500.00 75.00 37,500

TOTAL C/O TO SUMMARY


37,500

274
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
RESIDENTIAL TYPE 1 &2

SH -01 CIVIL WORKS FOR FIRE PROTECTION SYSTEM


(NON-DSR Items)

1.1 Providing & fixing M.S. structural work fabricated from standard section e.g. M.S
rounds bar, angles, channels, plates including cutting to size,drilling,welding fixing
and welding to insert plates in RCC structural members as recommended size of
fasteners to RCC slab as directed by engineer-in-charge including cutting and
making good the walls, ceilings and floors (for pipe structural supports, U clamps
etc.)
Kg 400.00 75.00 30,000

TOTAL C/O TO SUMMARY


30,000

RESIDENTIAL TYPE 3 & 4


SH -01 CIVIL WORKS FOR FIRE PROTECTION SYSTEM (NON-DSR Items)

1.1 Providing & fixing M.S. structural work fabricated from standard section e.g. M.S
rounds bar, angles, channels, plates including cutting to size,drilling,welding fixing
and welding to insert plates in RCC structural members as recommended size of
fasteners to RCC slab as directed by engineer-in-charge including cutting and
making good the walls, ceilings and floors (for pipe structural supports, U clamps
etc.) Kg 600.00 75.00 45,000
TOTAL C/O TO SUMMARY
45,000

SUBJECT: ESTIMATE FOR EXTERNAL CIVIL WORKS


COST SUMMARY

S.NO. DESCRIPTION AMOUNT

SH-01A CIVIL WORKS FOR FIRE PROTECTION SYSTEM (DSR ITEMS)


112,666

SH-01B CIVIL WORKS FOR FIRE PROTECTION SYSTEM (NON-DSR ITEMS)


143,800
TOTAL CARRIED OVER TO SUMMARY 256,466

275
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUBJECT: ESTIMATE FOR EXTERNAL CIVIL WORKS

SH -01A CIVIL WORKS FOR FIRE PROTECTION SYSTEM (DSR Items)

1.1 DSR Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement
18.35 mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm
top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid
and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement :
5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a
floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Each 7.00 16,095.10 112,666

TOTAL C/O TO SUMMARY


112,666

SH -01B CIVIL WORKS FOR FIRE PROTECTION SYSTEM (NON-DSR Items)

1.1 Providing and laying reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
stone aggregate 20mm nominal size) for anchor/thrust blocks, complete i/c
shuttering, centering curing, and reinforcement including removal of shuttering
complete. Cum. 20.00 7,190.00 143,800

TOTAL C/O TO SUMMARY


143,800

276
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

4 GRAND SUMMARY FOR FIRE FIGHTING WORKS & PUMPS EQUIPMENTS

HEAD ESTIMATED
S.NO. AMOUNT IN INR

4.01
ESTIMATE OF INTERNAL FIRE FIGHTING SERVICES

ACADEMIC & ADMIN BLOCK 16,291,223

4.01.1
HOSTEL BLOCK 8,365,170

4.01.2
RESIDENTIAL TYPE 1 &2 3,794,277
4.01.3
RESIDENTIAL TYPE 3 & 4 7,321,675

SUB TOTAL 4.01 35,772,345

4.02 ESTIMATE OF EXTERNAL FIRE FIGHTING SERVICES 6,118,090

4.03 FIRE FIGHTING PUMPS & EQUIPMENTS 5,092,210

TOTAL AMOUNT CARRIED TO SUMMARY (4.01 + 4.02 + 4.03)


46,982,645

277
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUBJECT:ESTIMATE FOR INTERNAL FIRE FIGHTING SERVICES FOR ACADEMIC & ADMIN BLOCK

SUB SUBHEAD OF WORK ESTMATED


HEAD NO AMOUNT IN INR

SH-01 PIPES AND VALVES


1,210,434

FIRE FIGHTING EQUIPMENTS & ACCESSORIES FOR INTERNAL HYDRANT


SH-02 SYSTEM
3,110,685

PORTABLE FIRE EXTINGUISHERS


SH-03
1,004,065

AUTOMATIC SPRINKLER SYSTEM


SH-04
11,823,472

TOTAL CARRIED OVER TO SUMMARY


(SH01 + SH02 +SH03 + SH04 ) 17,148,656

LESS 5% FOR UPRNN WORKING (857,433)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 16,291,223

278
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
XII FIRE FIGHTING SERVICES
SH 01. PIPES AND VALVES

1.1 Pipes for Internal Wet Riser System / Headers -


M.S. Black ERW Heavy grade class 'C' piping as per IS: 1239. The pipes being
suspended from ceilings by using supports complete with necessary specials such
as tees,bends, flanges, reducers, orifice plates etc. Rate quoted shall include for
painting of pipe with a coat of primer and two coats of synthetic enamel paint of
approved colour/ make for above ground piping as per the TAC / IS standards and
local fire service department requirement complete including supply and installation
of G.I. threaded Rods, clamps, angle and , fasteners etc., (M.S. Structural support
i.e. MS Channel, plate if required to be paid separately).
-
Above ground piping with necessary flanges and fittings such as elbows, Tees and
painting support and Orifice plates if any necessary for the system complete as per
the requiremet of local Fire Service Department.
-
a) 150mm dia
R.M. 600.00 1,665.00 999,000
b) 100mm dia
R.M. 10.00 1,135.00 11,350
c) 80mm dia
R.M. 55.00 870.00 47,850
d) 25mm dia
R.M. 55.00 350.80 19,294
-
1.2 Providing & fixing Non return valve of CI body for PN 1.6 rating, conforming to
IS:5312 with matching flanges, nut , bolts & gasket complete in all respects. -
a) 150mm dia Each 2.00 11,820.00 23,640

1.3 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, with matching flanges,
nut , bolts & gasket conforming to IS:13095/BS:5155.
-
a) 150mm dia Each 4.00 4,275.00 17,100
-
1.4 Providing and Fixing Copper Alloy 25 mm Air release valve, having threaded
connection including the cost of 25 mm dia stainless steel Gate valve with required
fittings as per standard design. Each 4.00 1,470.00 5,880
-
1.5 Providing and fixing stainless steel fullway valve with wheel tested to 20 Kg/cm2 of
approved quality as per I.S:778. Class-II -
a) 25 mm dia Each 52.00 1,660.00 86,320
TOTAL C/O TO SUMMARY
1,210,434

279
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH -02 FIRE FIGHTING EQUIPMENTS & ACCESSORIES

2.1 FOR INTERNAL HYDRANT SYSTEM


-
-
2.1.1 Providing and fixing stainless steel steel Internal fire hydrant valve single headed
oblique pattern to type ‘A’ of I.S: 5290-1977 with 80 NB flange inlet with 63mm dia
instantaneous SS female coupling , with blank caps and chain complete with
instantaneous spring lock complete in all respect.
-
-
a) stainless steel Landing Valve
Each 52.00 8,480.00 440,960
-
2.1.2 Providing and fixing standard short size branch pipe with hand operated stainless
steel 20mm nominal bore outlet with standard instantaneous type 63mm dia
coupling as per IS: 903 complete as required.
-
-
a) stainless steel branch pipe
Each 52.00 2,595.00 134,940
-
2.1.3 Providing and fixing first aid fire hose reel (with wall mounting swinging-type drum
complying to IS:884), fitted with Thermo Plastic Synthetic Reinforced material
conforming to IS:12585-1988 Type II 20 mm bore and 36.5 m long, with standard
size outlet shut off Nozzle with 25 mm ball valve, brackets, complete in all respects.
( MS/GI Connection Pipe measured separately )

Each 52.00 9,000.00 468,000


-
2.1.4 Providing and fixing 63mm dia 15m long RRL - Reinforced rubberized fabric lined
hose including stainless steel male and female instantaneous type coupling approved
by fire authority, machine wound with copper wire complete in all respects hose to
IS:636 type-II and male, female coupling to IS: 903 with ISI certification. The Hose
shall be rated for burst pressure of 37.5 kg/ cm2
Each 104.00 7,015.00 729,560
-
2.1.5 Providing and fixing standard fire mans axe with heavy duty insulated rubber handle
as per IS: 926 with clamps.
Each 52.00 815.00 42,380
-

280
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.1.6 Providing and Fixing Indoor fire hose door, frame fabricated from MS angle with
double glazed front door of 16 gauge M.S sheet and locking arrangement, painted
“Fire Hose” with stove enameled paint, written on front, including necessary supports
of approximate size 2100x1200x900mm deep to house two lengths of RRL hose with
couplings, branch pipe and first aid hose reel Drum with rubber hose and nozzle and
fire axe and single outlet landing valve complete in all respects. The door shall be
painted with one coat of primer and two or more coats of Synthetic enamel paint of
approved make or shade as required. Each 52.00 22,065.00 1,147,380
-
2.1.7 Providing and fixing 100mm dia two-way fire brigade inlet connection consisting of 2
nos 63mm size instantaneously type male coupling and shall be protected by cap
scored with a chain glass bore etc. complete with one 100mm dia sluice valve and
100mm dia non-return valve (To be connected to external ring main/wet riser/down
comer)
Each 3.00 49,155.00 147,465
-
TOTAL C/O TO SUMMARY
3,110,685

SH 03 PORTABLE FIRE EXTINGUISHERS

3.1 'ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate )
fire extinguisher with fixing hangers, hose, brackets, screws to required size etc.,
complete as per IS:15683.
-
-
a) 6 Kg. Capacity
Each 50.00 5,400.00 270,000
-
3.2 CO2 gas type cylindrical shape fire extinguisher with fixing hangers, hose, brackets,
screws to required size etc.,complete as per IS:15683 - wall mounted type.

-
-
a) 4.5 Kg. Capacity
Each 50.00 12,575.00 628,750
-
3.3 CO2 type cylindrical shape fire extinguisher with hose and all required accessories,
complete as per IS:2878 - trolley mounted type for portable use.
-

281
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
a) 22.5 Kg. Capacity
Each 2.00 39,105.00 78,210
-
3.4 Aquous Film Forming Foam (AFFF) media cylindrical shape fire extinguisher with
gas cartridge, hose and all required accessories, complete as per IS:13386 - trolley
mounted type for portable use.
-
-
a) 50 Liters Capacity
Each 1.00 21,015.00 21,015
-
3.5 Providing and Fixing 3 Nos. G.I. sand buckets painted "Red Color" complete with G.I.
stand duly painted "Red Color" of suitable size to hang 3 Buckets at a time as per
required specifications.
Set 3.00 2,030.00 6,090
-
TOTAL C/O TO SUMMARY
1,004,065

SH 04 AUTOMATIC SPRINKLER SYSTEM -


-
4.1 Pipes for Sprinkler System Branches/Headers
-
M.S. Black ERW Heavy grade "C Class" piping as per IS: 1239. The pipes being
suspended from ceilings by using supports complete with necessary specials such
as tees,bends, flanges, reducers, etc. Rate quoted shall include for painting of pipe
with a coat of primer and two coats of synthetic enamel paint of approved colour/
make for above ground piping as per the NBC / IS standards and local fire service
department requirement complete including supply and installation of installation of
G.I. threaded Rods, clamps , angle and fasteners etc., (M.S. Structural support i. e.
MS channel , plates if required, to be paid separately)
(Note : Pipes upto and including 50 mm dia shall be threaded joints, 65 mm
and above shall be welded joints.)

-
-
a) 150mm dia
Meter 710.00 1,665.00 1,182,150
-
b) 100mm dia
Meter 1,730.00 1,135.00 1,963,550
-
c) 80mm dia
Meter 1,380.00 870.00 1,200,600

282
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
d) 65mm dia
Meter 535.00 725.00 387,875
-
e) 50mm dia
Meter 485.00 600.00 291,000
-
f) 40mm dia
Meter 465.00 465.00 216,225
-
g) 32mm dia Meter 465.00 415.00 192,975
-
h) 25mm dia
Meter 9,740.00 350.80 3,416,792
-
4.2 Providing, fixing, and testing of 15mm dia. Chrome finished sprinkler head with
standard response quartz bulb and to operate at 68°C (of Min K-Factor 5.6) complete
as per given specifications.(UL Listed/FM Approved)
-
-
a) Pendant/Upright (Standard Spray)
Each 4,250.00 390.00 1,657,500
-
b) Side wall Sprinklers (Standard Spray)
Each 20.00 590.00 11,800
-
c) Concealed Type Sprinklers
Each 40.00 1,350.00 54,000
-
4.3 Extra over on above sprinkler item for providing chrome finished Rosette plate with
twin - piece recessed escutcheon plate, UL Listed / FM Approved, suitable for 15
mm size sprinklers.
Each 90.00 260.00 23,400
-
4.4 M.S. cabinet (size 600x450x150mm) fabricated from 16 gauge M.S. sheet with full
front glass door and locking arrangement with suitable shelves for keeping spare
sprinklers and one no. spanner properly fixed. Cabinet painted with enamel paint of
approved shade.
Each 2.00 3,290.00 6,580
-
4.5 Providing and fixing forged brass lever operated ball valve of full flow with forged
brass ball (Machined to mirror smooth finish with hard chrome plated) and spindle
with setting and gland of superior quality having minimum working pressure of 10
kg/cm2 etc. complete in all respect. (For Drain Valves)
-
-
a) 50 mm dia
Each 20.00 2,630.00 52,600

283
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
4.6 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, conforming to IS:13095
/ BS:5155. including matching flanges, gasket, nut & bolts etc.
-
-
a) 150 mm dia
Each 12.00 4,275.00 51,300
-
b) 100 mm dia Each 8.00 3,320.00 26,560
-
4.7 Providing and fixing 25 mm inspecting, testing and drain assembly for installation on
Sprinkler System, in brass body consisting of steel single lever 25 mm CP ball valve
for multiple test and drain functions, including inlet connection of specified size, 25
mm sight glass, connections to the main header and line drain complete as per
requirements. Product shall suitable for min. 10 kg/cm2 working pressure and shall
be UL Listed / FM Approved.
Each 20.00 5,910.00 118,200
-
4.8 Providing and fixing electrically operated flow indicating switches/water flow
detectors for indicating water flow in sprinkler branch line consisting of NEMA 4 rated
enclosure for vertical/horizontal mounting, to be installed as per manufacturer
specifications in an accessible location as per site, complete including wiring to
monitor modules as per instructions of the engineer-in-charge, for the below pipe
sizes. -
-
a) 80 to 150 mm Dia. Each 20.00 5,195.00 103,900
-
4.9 Providing and fixing electrical Monitor Modules to monitor the water flow
devices/flows witches with built-in identification system indicating switches/water flow
detectors of 15-32v DC operating voltage to be installed as per manufacturer
specifications in an accessible location as per site, complete, excluding wiring to
Annunciation Panel, with UL/CE/LPCB approval. Each 20.00 3,640.00 72,800
-
4.10 Providing and fixing electrical Fault-isolation Modules to protect the system against
wire to wire short circuits on loops, to be installed at the rate of after every 5 nos.
monitor modules complete as per manufacturer specifications and in an accessible
location as per site, excluding wiring to Annunciation Panel, with UL/CE/LPCB
approval.
Each 4.00 3,320.00 13,280
-

284
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
4.11 Providing and fixing intelligent-type Micro proccessor based Sprinkler Annunciation
Panel , compatible for seamless integration with waterflow devices, main fire alarm
panel and BMS systems (programmable outputs), with LCD type display & LED
indication for all zones, complete with internal sounder, alarm/fault indications &
standby 24v lead acid batteries with charger.
-
a) For minimum 40 zones (20 Working + 20 spare) Each 1.00 100,335.00 100,335
4.12 Providing, fixing & pressure testing of flexible tubes stainless steel steel steel
braided type for connecting pendant sprinklers to branch lines, complete with all
necessary accessories, reducers, O-rings, nipples etc. of approved specifications &
make, complete with supporting structural arrangments in the false ceiling/slab as
per instructions of the engineer-in-charge, for the below lengths, as per the
reccommended lengths.
-
a) For 700mm Length Each 35.00 1,760.00 61,600
b) For 1000mm Length Each 25.00 1,870.00 46,750
c) For 1500mm Length Each 20.00 1,950.00 39,000
4.13 Providing,fixing and testing of 150mm dia alarm check valve with ACV trim set to
water motor alarm gong, retard chamber, UL Listed/FM approved, complete with
drain cock arrangement and with all accessories, welded or screwed as
required including cutting holes and chased in brick or RCC walls and making
good complete as per approved model.
Each 2.00 41,275.00 82,550
4.14 Providing and fixing heavy duty copper armored cables 1.1 KVA grade including
necessary support clamps at ceiling level and connection legs and double
compression glands,complete in all respects.
-
a) Control cable 2 core 1.5 Sq.mm Metre 90.00 260.00 23,400
4.15 Providing, fixing, testing & commissioning of deluge valve with wet pilot trim
(Hydraulic Release) / electric release trim test and alarm rim complete with all
accessories viz. fittings, pressure gauge, valves, actuator, manifold etc. alarm gong
including up stream & down stream main header valve (for Pseudo
Compartmentation).
-
a) 100 mm dia No. 5.00 71,860.00 359,300
4.16 Providing, fixing, testing and commissioning of 15 mm dia forged brass medium
velocity water spray open nozzle type sprinkler head (K-23, with an angle of 110
Degree) with a flow rate of 27.21 LPM and a pressure of 1.5 Kg/cm2. (Installation
shall be as per NFPA recommendation)
Each 190.00 355.00 67,450
-
TOTAL C/O TO SUMMARY
11,823,472

285
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUBJECT:ESTIMATE FOR INTERNAL FIRE FIGHTING SERVICES FOR HOSTEL BLOCK

SUBHEAD ESTIMATED
S.NO. AOUNT IN INRe

PIPES AND VALVES


SH-01
550,492

FIRE FIGHTING EQUIPMENTS & ACCESSORIES FOR INTERNAL HYDRANT SYSTEM


SH-02
2,393,665

PORTABLE FIRE EXTINGUISHERS


SH-03 822,285

AUTOMATIC SPRINKLER SYSTEM


SH-04
5,039,000

TOTAL CARRIED OVER TO SUMMARY


(SH01 + SH02 +SH03 + SH04 )
8,805,442

LESS 5% FOR UPRNN WORKING (440,272)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 8,365,170

286
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
FIRE FIGHTING SERVICES
XII

SH 01. PIPES AND VALVES

1.1 Pipes for Internal Wet Riser System / Headers


-
-
M.S. Black ERW Heavy grade class 'C' piping as per IS: 1239. The pipes being
suspended from ceilings by using supports complete with necessary specials such
as tees,bends, flanges, reducers, orifice plates etc. Rate quoted shall include for
painting of pipe with a coat of primer and two coats of synthetic enamel paint of
approved colour/ make for above ground piping as per the TAC / IS standards and
local fire service department requirement complete including supply and installation
of G.I. threaded Rods, clamps, angle and , fasteners etc., (M.S. Structural support
i.e. MS Channel, plate if required to be paid separately).
-
Above ground piping with necessary flanges and fittings such as elbows, Tees and
painting support and Orifice plates if any necessary for the system complete as per
the requiremet of local Fire Service Department.
-
a) 150mm dia R.M. 225.00 1,665.00 374,625
-
b) 100mm dia
R.M. 10.00 1,135.00 11,350
-
c) 80mm dia
R.M. 40.00 870.00 34,800
-
d) 25mm dia
R.M. 40.00 350.80 14,032
-
1.4 Providing & fixing Non return valve of CI body for PN 1.6 rating, conforming to
IS:5312 with matching flanges, nut , bolts & gasket complete in all respects.
-
-
a) 150mm dia
Each 1.00 11,820.00 11,820

-
1.5 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, with matching flanges,
nut , bolts & gasket conforming to IS:13095/BS:5155.
-
-

287
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a) 150mm dia
Each 7.00 4,275.00 29,925
-
1.6 Providing and Fixing Copper Alloy 25 mm Air release valve, having threaded
connection including the cost of 25 mm dia stainless steel Gate valve with required
fittings as per standard design.
Each 4.00 1,470.00 5,880
-
1.7 Providing and fixing stainless steel fullway valve with wheel tested to 20 Kg/cm2 of
approved quality as per I.S:778. Class-II
-
-
a) 25 mm dia
Each 41.00 1,660.00 68,060
-
TOTAL C/O TO SUMMARY
550,492
-
SH -02 FIRE FIGHTING EQUIPMENTS & ACCESSORIES
-
-
FOR INTERNAL HYDRANT SYSTEM -
-
2.1 Providing and fixing stainless steel steel Internal fire hydrant valve single headed
oblique pattern to type ‘A’ of I.S: 5290-1977 with 80 NB flange inlet with 63mm dia
instantaneous SS female coupling , with blank caps and chain complete with
instantaneous spring lock complete in all respect. -
-
a) stainless steel Landing Valve Each 41.00 8,480.00 347,680
-
2.2 Providing and fixing standard short size branch pipe with hand operated stainless
steel 20mm nominal bore outlet with standard instantaneous type 63mm dia
coupling as per IS: 903 complete as required.
-
-
a) stainless steel branch pipe
Each 41.00 2,595.00 106,395
-
2.3 Providing and fixing first aid fire hose reel (with wall mounting swinging-type drum
complying to IS:884), fitted with Thermo Plastic Synthetic Reinforced material
conforming to IS:12585-1988 Type II 20 mm bore and 36.5 m long, with standard
size outlet shut off Nozzle with 25 mm ball valve, brackets, complete in all respects.
( MS/GI Connection Pipe measured separately )
Each 38.00 9,000.00 342,000
-

288
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.4 Providing and fixing 63mm dia 15m long RRL - Reinforced rubberized fabric lined
hose including stainless steel male and female instantaneous type coupling approved
by fire authority, machine wound with copper wire complete in all respects hose to
IS:636 type-II and male, female coupling to IS: 903 with ISI certification. The Hose
shall be rated for burst pressure of 37.5 kg/ cm2
Each 80.00 7,015.00 561,200
-
2.5 Providing and fixing standard fire mans axe with heavy duty insulated rubber handle
as per IS: 926 with clamps.
Each 41.00 815.00 33,415
-
2.6 Providing and Fixing Indoor fire hose door, frame fabricated from MS angle with
double glazed front door of 16 gauge M.S sheet and locking arrangement, painted
“Fire Hose” with stove enameled paint, written on front, including necessary supports
of approximate size 2100x1200x900mm deep to house two lengths of RRL hose with
couplings, branch pipe and first aid hose reel Drum with rubber hose and nozzle and
fire axe and single outlet landing valve complete in all respects. The door shall be
painted with one coat of primer and two or more coats of Synthetic enamel paint of
approved make or shade as required.
Each 41.00 22,065.00 904,665
-
2.7 Providing and fixing 100mm dia two-way fire brigade inlet connection consisting of 2
nos 63mm size instantaneously type male coupling and shall be protected by cap
scored with a chain glass bore etc. complete with one 100mm dia sluice valve and
100mm dia non-return valve (To be connected to external ring main/wet riser/down
comer) Each 2.00 49,155.00 98,310
-
TOTAL C/O TO SUMMARY
2,393,665

289
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH 03 PORTABLE FIRE EXTINGUISHERS
-
-
3.1 'ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate )
fire extinguisher with fixing hangers, hose, brackets, screws to required size etc.,
complete as per IS:15683.
-
-
a) 6 Kg. Capacity
Each 40.00 5,400.00 216,000
-
3.2 CO2 gas type cylindrical shape fire extinguisher with fixing hangers, hose, brackets,
screws to required size etc.,complete as per IS:15683 - wall mounted type.

-
-
a) 4.5 Kg. Capacity
Each 40.00 12,575.00 503,000
-
3.3 CO2 type cylindrical shape fire extinguisher with hose and all required accessories,
complete as per IS:2878 - trolley mounted type for portable use.

-
-
a) 22.5 Kg. Capacity
Each 2.00 39,105.00 78,210
-
3.4 Aquous Film Forming Foam (AFFF) media cylindrical shape fire extinguisher with
gas cartridge, hose and all required accessories, complete as per IS:13386 - trolley
mounted type for portable use.

-
-
a) 50 Liters Capacity
Each 1.00 21,015.00 21,015
-
3.5 Providing and Fixing 3 Nos. G.I. sand buckets painted "Red Color" complete with G.I.
stand duly painted "Red Color" of suitable size to hang 3 Buckets at a time as per
required specifications.
Set 2.00 2,030.00 4,060
-
TOTAL C/O TO SUMMARY

822,285
-

290
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH 04 AUTOMATIC SPRINKLER SYSTEM
-
-
4.1 Pipes for Sprinkler System Branches/Headers
-
M.S. Black ERW Heavy grade "C Class" piping as per IS: 1239. The pipes being
suspended from ceilings by using supports complete with necessary specials such
as tees,bends, flanges, reducers, etc. Rate quoted shall include for painting of pipe
with a coat of primer and two coats of synthetic enamel paint of approved colour/
make for above ground piping as per the NBC / IS standards and local fire service
department requirement complete including supply and installation of installation of
G.I. threaded Rods, clamps , angle and fasteners etc., (M.S. Structural support i. e.
MS channel , plates if required, to be paid separately)
(Note : Pipes upto and including 50 mm dia shall be threaded joints, 65 mm
and above shall be welded joints.)
-
a) 150mm dia
Meter 310.00 1,665.00 516,150
b) 100mm dia
Meter 150.00 1,135.00 170,250
c) 80mm dia
Meter 110.00 870.00 95,700
d) 65mm dia
Meter 230.00 725.00 166,750
e) 50mm dia
Meter 460.00 600.00 276,000
f) 40mm dia
Meter 700.00 465.00 325,500
g) 32mm dia
Meter 510.00 415.00 211,650
h) 25mm dia
Meter 3,250.00 350.80 1,140,100
-
4.2 Providing, fixing, and testing of 15mm dia. Chrome finished sprinkler head with
standard response quartz bulb and to operate at 68°C (of Min K-Factor 5.6) complete
as per given specifications.(UL Listed/FM Approved)
-
a) Pendant/Upright (Standard Spray)
Each 934.00 390.00 364,260
b) Side wall Sprinklers (Standard Spray)
Each 228.00 590.00 134,520
c) Side wall Sprinklers (Extended Coverage Type) of required "K' factor.
Each 180.00 1,140.00 205,200
d) Concealed Type Sprinklers
Each 70.00 1,350.00 94,500
-

291
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
4.3 Extra over on above sprinkler item for providing chrome finished Rosette plate with
twin - piece recessed escutcheon plate, UL Listed / FM Approved, suitable for 15
mm size sprinklers.
Each 20.00 260.00 5,200
-
4.4 M.S. cabinet (size 600x450x150mm) fabricated from 16 gauge M.S. sheet with full
front glass door and locking arrangement with suitable shelves for keeping spare
sprinklers and one no. spanner properly fixed. Cabinet painted with enamel paint of
approved shade.
Each 1.00 3,290.00 3,290
-
4.5 Providing and fixing forged brass lever operated ball valve of full flow with forged
brass ball (Machined to mirror smooth finish with hard chrome plated) and spindle
with setting and gland of superior quality having minimum working pressure of 10
kg/cm2 etc. complete in all respect. (For Drain Valves)
-
-
a) 50 mm dia
Each 38.00 2,630.00 99,940
-
4.6 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, conforming to IS:13095
/ BS:5155. including matching flanges, gasket, nut & bolts etc.
-
a) 150 mm dia
Each 2.00 4,275.00 8,550
b) 100 mm dia
Each 30.00 3,320.00 99,600
c) 80 mm dia
Each 4.00 2,985.00 11,940
-
4.7 Providing and fixing 25 mm inspecting, testing and drain assembly for installation on
Sprinkler System, in brass body consisting of steel single lever 25 mm CP ball valve
for multiple test and drain functions, including inlet connection of specified size, 25
mm sight glass, connections to the main header and line drain complete as per
requirements. Product shall suitable for min. 10 kg/cm2 working pressure and shall
be UL Listed / FM Approved.
Each 38.00 5,910.00 224,580
-
4.8 Providing and fixing electrically operated flow indicating switches/water flow
detectors for indicating water flow in sprinkler branch line consisting of NEMA 4 rated
enclosure for vertical/horizontal mounting, to be installed as per manufacturer
specifications in an accessible location as per site, complete including wiring to
monitor modules as per instructions of the engineer-in-charge, for the below pipe
sizes. -
-

292
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a) 80 to 150 mm Dia.
Each 38.00 5,195.00 197,410
-
4.9 Providing and fixing electrical Monitor Modules to monitor the water flow
devices/flows witches with built-in identification system indicating switches/water flow
detectors of 15-32v DC operating voltage to be installed as per manufacturer
specifications in an accessible location as per site, complete, excluding wiring to
Annunciation Panel, with UL/CE/LPCB approval.
Each 38.00 3,640.00 138,320
-
4.10 Providing and fixing electrical Fault-isolation Modules to protect the system against
wire to wire short circuits on loops, to be installed at the rate of after every 5 nos.
monitor modules complete as per manufacturer specifications and in an accessible
location as per site, excluding wiring to Annunciation Panel, with UL/CE/LPCB
approval.
Each 8.00 3,320.00 26,560
-
4.11 Providing and fixing intelligent-type Micro proccessor based Sprinkler Annunciation
Panel , compatible for seamless integration with waterflow devices, main fire alarm
panel and BMS systems (programmable outputs), with LCD type display & LED
indication for all zones, complete with internal sounder, alarm/fault indications &
standby 24v lead acid batteries with charger.
-
For minimum 76 zones (38 Working + 38 spare)
a) Each 1.00 184,620.00 184,620
-
4.12 Providing, fixing & pressure testing of flexible tubes stainless steel steel steel
braided type for connecting pendant sprinklers to branch lines, complete with all
necessary accessories, reducers, O-rings, nipples etc. of approved specifications &
make, complete with supporting structural arrangments in the false ceiling/slab as
per instructions of the engineer-in-charge, for the below lengths, as per the
reccommended lengths.
-
For 700mm Length
a) Each 20.00 1,760.00 35,200
For 1000mm Length
b) Each 15.00 1,870.00 28,050
For 1500mm Length
c) Each 10.00 1,950.00 19,500
-
4.13 Providing,fixing and testing of 150mm dia alarm check valve with ACV trim set to
water motor alarm gong, retard chamber, UL Listed/FM approved, complete with
drain cock arrangement and with all accessories, welded or screwed as
required including cutting holes and chased in brick or RCC walls and making
good complete as per approved model.
Each 2.00 41,275.00 82,550
-

293
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
4.14 Providing and fixing heavy duty copper armored cables 1.1 KVA grade including
necessary support clamps at ceiling level and connection legs and double
compression glands,complete in all respects.
-
-
a) Control cable 2 core 1.5 Sq.mm
Metre 130.00 260.00 33,800
-
4.15 Providing, fixing, testing & commissioning of deluge valve with wet pilot trim
(Hydraulic Release) / electric release trim test and alarm rim complete with all
accessories viz. fittings, pressure gauge, valves, actuator, manifold etc. alarm gong
including up stream & down stream main header valve (for Pseudo
Compartmentation).
-
-
a) 80 mm dia
No. 2.00 63,975.00 127,950

4.16 Providing, fixing, testing and commissioning of 15 mm dia forged brass medium
velocity water spray open nozzle type sprinkler head (K-23, with an angle of 110
Degree) with a flow rate of 27.21 LPM and a pressure of 1.5 Kg/cm2. (Installation
shall be as per NFPA recommendation)
Each 32.00 355.00 11,360
-
TOTAL C/O TO SUMMARY
5,039,000

294
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUBJECT:ESTIMATE FOR INTERNAL FIRE FIGHTING SERVICES FOR RESIDENTIAL TYPE 1 &2

SUBHEAD OF WORKS ESTIMATED


S.NO. AMOUNT IN INR

PIPES AND VALVES


SH-01
262,346

FIRE FIGHTING EQUIPMENTS & ACCESSORIES FOR INTERNAL HYDRANT


SH-02 SYSTEM
1,017,900

PORTABLE FIRE EXTINGUISHERS


SH-03
309,635

AUTOMATIC SPRINKLER SYSTEM


SH-04
2,404,095

TOTAL CARRIED OVER TO SUMMARY


(SH01 + SH02 +SH03 + SH04 )
3,993,976

LESS 5% FOR UPRNN WORKING (199,699)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 3,794,277

295
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

FIRE FIGHTING SERVICES


XII
SH 01. PIPES AND VALVES

1.1 Pipes for Internal Wet Riser System / Headers


-
-
M.S. Black ERW Heavy grade class 'C' piping as per IS: 1239. The pipes being
suspended from ceilings by using supports complete with necessary specials such
as tees,bends, flanges, reducers, orifice plates etc. Rate quoted shall include for
painting of pipe with a coat of primer and two coats of synthetic enamel paint of
approved colour/ make for above ground piping as per the TAC / IS standards and
local fire service department requirement complete including supply and installation
of G.I. threaded Rods, clamps, angle and , fasteners etc., (M.S. Structural support
i.e. MS Channel, plate if required to be paid separately).
-
Above ground piping with necessary flanges and fittings such as elbows, Tees and
painting support and Orifice plates if any necessary for the system complete as per
the requiremet of local Fire Service Department.
-
a) 150mm dia
R.M. 100.00 1,665.00 166,500
b) 100mm dia
R.M. 10.00 1,135.00 11,350
c) 80mm dia
R.M. 20.00 870.00 17,400
d) 25mm dia
R.M. 20.00 350.80 7,016
-
1.2 Providing & fixing Non return valve of CI body for PN 1.6 rating, conforming to
IS:5312 with matching flanges, nut , bolts & gasket complete in all respects.
-
-
a) 150mm dia
Each 1.00 11,820.00 11,820
-

296
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
1.3 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, with matching flanges,
nut , bolts & gasket conforming to IS:13095/BS:5155.
-
a) 150mm dia
Each 4.00 4,275.00 17,100
-
1.4 Providing and Fixing Copper Alloy 25 mm Air release valve, having threaded
connection including the cost of 25 mm dia stainless steel Gate valve with required
fittings as per standard design.
Each 2.00 1,470.00 2,940
-
1.5 Providing and fixing stainless steel fullway valve with wheel tested to 20 Kg/cm2 of
approved quality as per I.S:778. Class-II
-
a) 25 mm dia
Each 17.00 1,660.00 28,220
-
TOTAL C/O TO SUMMARY
262,346
-
SH -02 FIRE FIGHTING EQUIPMENTS & ACCESSORIES
-
-
FOR INTERNAL HYDRANT SYSTEM
-
-
2.1 Providing and fixing stainless steel steel Internal fire hydrant valve single headed
oblique pattern to type ‘A’ of I.S: 5290-1977 with 80 NB flange inlet with 63mm dia
instantaneous SS female coupling , with blank caps and chain complete with
instantaneous spring lock complete in all respect.
-
a) stainless steel Landing Valve
Each 17.00 8,480.00 144,160
-
2.2 Providing and fixing standard short size branch pipe with hand operated stainless
steel 20mm nominal bore outlet with standard instantaneous type 63mm dia
coupling as per IS: 903 complete as required.
-
a) stainless steel branch pipe
Each 17.00 2,595.00 44,115
-

297
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.3 Providing and fixing first aid fire hose reel (with wall mounting swinging-type drum
complying to IS:884), fitted with Thermo Plastic Synthetic Reinforced material
conforming to IS:12585-1988 Type II 20 mm bore and 36.5 m long, with standard
size outlet shut off Nozzle with 25 mm ball valve, brackets, complete in all respects.
( MS/GI Connection Pipe measured separately )
Each 17.00 9,000.00 153,000
-
2.4 Providing and fixing 63mm dia 15m long RRL - Reinforced rubberized fabric lined
hose including stainless steel male and female instantaneous type coupling approved
by fire authority, machine wound with copper wire complete in all respects hose to
IS:636 type-II and male, female coupling to IS: 903 with ISI certification. The Hose
shall be rated for burst pressure of 37.5 kg/ cm2
Each 34.00 7,015.00 238,510
-
2.5 Providing and fixing standard fire mans axe with heavy duty insulated rubber handle
as per IS: 926 with clamps.
Each 17.00 815.00 13,855
-
2.6 Providing and Fixing Indoor fire hose door, frame fabricated from MS angle with
double glazed front door of 16 gauge M.S sheet and locking arrangement, painted
“Fire Hose” with stove enameled paint, written on front, including necessary supports
of approximate size 2100x1200x900mm deep to house two lengths of RRL hose with
couplings, branch pipe and first aid hose reel Drum with rubber hose and nozzle and
fire axe and single outlet landing valve complete in all respects. The door shall be
painted with one coat of primer and two or more coats of Synthetic enamel paint of
approved make or shade as required.
Each 17.00 22,065.00 375,105
-
2.7 Providing and fixing 100mm dia two-way fire brigade inlet connection consisting of 2
nos 63mm size instantaneously type male coupling and shall be protected by cap
scored with a chain glass bore etc. complete with one 100mm dia sluice valve and
100mm dia non-return valve (To be connected to external ring main/wet riser/down
comer)
Each 1.00 49,155.00 49,155
-
TOTAL C/O TO SUMMARY
1,017,900
-

298
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH 03 PORTABLE FIRE EXTINGUISHERS
-
-
3.1 'ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate )
fire extinguisher with fixing hangers, hose, brackets, screws to required size etc.,
complete as per IS:15683.

-
-
a) 6 Kg. Capacity

Each 17.00 5,400.00 91,800


-
3.2 CO2 gas type cylindrical shape fire extinguisher with fixing hangers, hose, brackets,
screws to required size etc.,complete as per IS:15683 - wall mounted type.

-
-
a) 4.5 Kg. Capacity
Each 17.00 12,575.00 213,775
-
3.3 Providing and Fixing 3 Nos. G.I. sand buckets painted "Red Color" complete with G.I.
stand duly painted "Red Color" of suitable size to hang 3 Buckets at a time as per
required specifications.

Set 2.00 2,030.00 4,060


-
TOTAL C/O TO SUMMARY

309,635

299
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH 04 AUTOMATIC SPRINKLER SYSTEM
-
-
4.1 Pipes for Sprinkler System Branches/Headers
-
M.S. Black ERW Heavy grade "C Class" piping as per IS: 1239. The pipes being
suspended from ceilings by using supports complete with necessary specials such
as tees,bends, flanges, reducers, etc. Rate quoted shall include for painting of pipe
with a coat of primer and two coats of synthetic enamel paint of approved colour/
make for above ground piping as per the NBC / IS standards and local fire service
department requirement complete including supply and installation of installation of
G.I. threaded Rods, clamps , angle and fasteners etc., (M.S. Structural support i. e.
MS channel , plates if required, to be paid separately)
(Note : Pipes upto and including 50 mm dia shall be threaded joints, 65 mm
and above shall be welded joints.)
-
a) 150mm dia
Meter 80.00 1,665.00 133,200
b) 100mm dia
Meter 5.00 1,135.00 5,675
c) 80mm dia
Meter 185.00 870.00 160,950
d) 65mm dia
Meter 10.00 725.00 7,250
e) 50mm dia
Meter 110.00 600.00 66,000
f) 40mm dia
Meter 535.00 465.00 248,775
g) 32mm dia
Meter 320.00 415.00 132,800
h) 25mm dia
Meter 1,600.00 350.80 561,280
-
4.2 Providing, fixing, and testing of 15mm dia. Chrome finished sprinkler head with
standard response quartz bulb and to operate at 68°C (of Min K-Factor 5.6) complete
as per given specifications.(UL Listed/FM Approved)
-
a) Pendant/Upright (Standard Spray)
Each 190.00 390.00 74,100
b) Side wall Sprinklers (Standard Spray)
Each 300.00 590.00 177,000
c) Side wall Sprinklers (Extended Coverage Type) of required "K' factor.
Each 180.00 1,140.00 205,200
d) Concealed Type Sprinklers
Each 20.00 1,350.00 27,000
-

300
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
4.3 Extra over on above sprinkler item for providing chrome finished Rosette plate with
twin - piece recessed escutcheon plate, UL Listed / FM Approved, suitable for 15
mm size sprinklers.
Each 10.00 260.00 2,600
-
4.4 M.S. cabinet (size 600x450x150mm) fabricated from 16 gauge M.S. sheet with full
front glass door and locking arrangement with suitable shelves for keeping spare
sprinklers and one no. spanner properly fixed. Cabinet painted with enamel paint of
approved shade.
Each 1.00 3,290.00 3,290
-
4.5 Providing and fixing forged brass lever operated ball valve of full flow with forged
brass ball (Machined to mirror smooth finish with hard chrome plated) and spindle
with setting and gland of superior quality having minimum working pressure of 10
kg/cm2 etc. complete in all respect. (For Drain Valves)
-
a) 50 mm dia
Each 17.00 2,630.00 44,710
-
4.6 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, conforming to IS:13095
/ BS:5155. including matching flanges, gasket, nut & bolts etc.
-
a) 80 mm dia
Each 16.00 2,985.00 47,760
-
4.7 Providing and fixing 25 mm inspecting, testing and drain assembly for installation on
Sprinkler System, in brass body consisting of steel single lever 25 mm CP ball valve
for multiple test and drain functions, including inlet connection of specified size, 25
mm sight glass, connections to the main header and line drain complete as per
requirements. Product shall suitable for min. 10 kg/cm2 working pressure and shall
be UL Listed / FM Approved.
Each 17.00 5,910.00 100,470
-
4.8 Providing and fixing electrically operated flow indicating switches/water flow
detectors for indicating water flow in sprinkler branch line consisting of NEMA 4 rated
enclosure for vertical/horizontal mounting, to be installed as per manufacturer
specifications in an accessible location as per site, complete including wiring to
monitor modules as per instructions of the engineer-in-charge, for the below pipe
sizes.
-

301
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a) 80 to 150 mm Dia.
Each 17.00 5,195.00 88,315
-
4.9 Providing and fixing electrical Monitor Modules to monitor the water flow
devices/flows witches with built-in identification system indicating switches/water flow
detectors of 15-32v DC operating voltage to be installed as per manufacturer
specifications in an accessible location as per site, complete, excluding wiring to
Annunciation Panel, with UL/CE/LPCB approval.
Each 17.00 3,640.00 61,880
-
4.10 Providing and fixing electrical Fault-isolation Modules to protect the system against
wire to wire short circuits on loops, to be installed at the rate of after every 5 nos.
monitor modules complete as per manufacturer specifications and in an accessible
location as per site, excluding wiring to Annunciation Panel, with UL/CE/LPCB
approval.
Each 4.00 3,320.00 13,280
-
4.11 Providing and fixing intelligent-type Micro proccessor based Sprinkler Annunciation
Panel , compatible for seamless integration with waterflow devices, main fire alarm
panel and BMS systems (programmable outputs), with LCD type display & LED
indication for all zones, complete with internal sounder, alarm/fault indications &
standby 24v lead acid batteries with charger.
-
a) For minimum 24 zones (17 Working + 17 spare) Each 1.00 100,335.00 100,335
-
4.12 Providing, fixing & pressure testing of flexible tubes stainless steel steel steel
braided type for connecting pendant sprinklers to branch lines, complete with all
necessary accessories, reducers, O-rings, nipples etc. of approved specifications &
make, complete with supporting structural arrangments in the false ceiling/slab as
per instructions of the engineer-in-charge, for the below lengths, as per the
reccommended lengths.
-
For 700mm Length
a) Each 20.00 1,760.00 35,200
For 1000mm Length
b) Each 15.00 1,870.00 28,050
For 1500mm Length
c) Each 10.00 1,950.00 19,500
-
4.13 Providing,fixing and testing of 150mm dia alarm check valve with ACV trim set to
water motor alarm gong, retard chamber, UL Listed/FM approved, complete with
drain cock arrangement and with all accessories, welded or screwed as
required including cutting holes and chased in brick or RCC walls and making
good complete as per approved model.
Each 1.00 41,275.00 41,275

302
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
4.14 Providing and fixing heavy duty copper armored cables 1.1 KVA grade including
necessary support clamps at ceiling level and connection legs and double
compression glands,complete in all respects.

-
-
a) Control cable 2 core 1.5 Sq.mm
Metre 70.00 260.00 18,200
-
TOTAL C/O TO SUMMARY

2,404,095

303
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUBJECT:ESTIMATE FOR INTERNAL FIRE FIGHTING SERVICES FOR RESIDENTIAL TYPE 3 & 4

SUBHEAD OF WORKS ESTIMATED


S.NO. AMOUNT IN INR

SH-01 PIPES AND VALVES


543,971

FIRE FIGHTING EQUIPMENTS & ACCESSORIES FOR INTERNAL HYDRANT


SH-02 SYSTEM
2,263,740

PORTABLE FIRE EXTINGUISHERS


SH-03
790,395

AUTOMATIC SPRINKLER SYSTEM


SH-04
4,108,920

TOTAL CARRIED OVER TO SUMMARY


(SH01 + SH02 +SH03 + SH04 )
7,707,026

LESS 5% FOR UPRNN WORKING (385,351)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 7,321,675

304
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
XII FIRE FIGHTING SERVICES

SH 01. PIPES AND VALVES

1.1 Pipes for Internal Wet Riser System / Headers


-
-
M.S. Black ERW Heavy grade class 'C' piping as per IS: 1239. The pipes being
suspended from ceilings by using supports complete with necessary specials such
as tees,bends, flanges, reducers, orifice plates etc. Rate quoted shall include for
painting of pipe with a coat of primer and two coats of synthetic enamel paint of
approved colour/ make for above ground piping as per the TAC / IS standards and
local fire service department requirement complete including supply and installation
of G.I. threaded Rods, clamps, angle and , fasteners etc., (M.S. Structural support
i.e. MS Channel, plate if required to be paid separately).
-
Above ground piping with necessary flanges and fittings such as elbows, Tees and
painting support and Orifice plates if any necessary for the system complete as per
the requiremet of local Fire Service Department.
-
a) 150mm dia
R.M. 230.00 1,665.00 382,950
b) 100mm dia
R.M. 10.00 1,135.00 11,350
c) 80mm dia
R.M. 20.00 870.00 17,400
d) 50mm dia
R.M. 10.00 600.00 6,000
e) 25mm dia
R.M. 20.00 350.80 7,016
-
1.2 Providing & fixing Non return valve of CI body for PN 1.6 rating, conforming to
IS:5312 with matching flanges, nut , bolts & gasket complete in all respects.
-
-
a) 150mm dia
Each 1.00 11,820.00 11,820
-
1.3 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, with matching flanges,
nut , bolts & gasket conforming to IS:13095/BS:5155.
-
-

305
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a) 150mm dia
Each 9.00 4,275.00 38,475
-
1.4 Providing and Fixing Copper Alloy 25 mm Air release valve, having threaded
connection including the cost of 25 mm dia stainless steel Gate valve with required
fittings as per standard design.
Each 4.00 1,470.00 5,880
-
1.5 Providing and fixing stainless steel fullway valve with wheel tested to 20 Kg/cm2 of
approved quality as per I.S:778. Class-II
-
-
a) 25 mm dia
Each 38.00 1,660.00 63,080
-
TOTAL C/O TO SUMMARY
543,971
-
SH -02 FIRE FIGHTING EQUIPMENTS & ACCESSORIES
-
-
FOR INTERNAL HYDRANT SYSTEM
-
-
2.1 Providing and fixing stainless steel steel Internal fire hydrant valve single headed
oblique pattern to type ‘A’ of I.S: 5290-1977 with 80 NB flange inlet with 63mm dia
instantaneous SS female coupling , with blank caps and chain complete with
instantaneous spring lock complete in all respect.
-
-
a) stainless steel Landing Valve
Each 38.00 8,480.00 322,240

-
2.2 Providing and fixing standard short size branch pipe with hand operated stainless
steel 20mm nominal bore outlet with standard instantaneous type 63mm dia
coupling as per IS: 903 complete as required.
-
-
a) stainless steel branch pipe
Each 38.00 2,595.00 98,610
-

306
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.3 Providing and fixing first aid fire hose reel (with wall mounting swinging-type drum
complying to IS:884), fitted with Thermo Plastic Synthetic Reinforced material
conforming to IS:12585-1988 Type II 20 mm bore and 36.5 m long, with standard
size outlet shut off Nozzle with 25 mm ball valve, brackets, complete in all respects.
( MS/GI Connection Pipe measured separately )
Each 38.00 9,000.00 342,000
-
2.4 Providing and fixing 63mm dia 15m long RRL - Reinforced rubberized fabric lined
hose including stainless steel male and female instantaneous type coupling approved
by fire authority, machine wound with copper wire complete in all respects hose to
IS:636 type-II and male, female coupling to IS: 903 with ISI certification. The Hose
shall be rated for burst pressure of 37.5 kg/ cm2
Each 76.00 7,015.00 533,140
-
2.5 Providing and fixing standard fire mans axe with heavy duty insulated rubber handle
as per IS: 926 with clamps.
Each 38.00 815.00 30,970
-
2.6 Providing and Fixing Indoor fire hose door, frame fabricated from MS angle with
double glazed front door of 16 gauge M.S sheet and locking arrangement, painted
“Fire Hose” with stove enameled paint, written on front, including necessary supports
of approximate size 2100x1200x900mm deep to house two lengths of RRL hose with
couplings, branch pipe and first aid hose reel Drum with rubber hose and nozzle and
fire axe and single outlet landing valve complete in all respects. The door shall be
painted with one coat of primer and two or more coats of Synthetic enamel paint of
approved make or shade as required. Each 38.00 22,065.00 838,470
-
2.7 Providing and fixing 100mm dia two-way fire brigade inlet connection consisting of 2
nos 63mm size instantaneously type male coupling and shall be protected by cap
scored with a chain glass bore etc. complete with one 100mm dia sluice valve and
100mm dia non-return valve (To be connected to external ring main/wet riser/down
comer)
Each 2.00 49,155.00 98,310
-
TOTAL C/O TO SUMMARY
2,263,740
-
SH 03 PORTABLE FIRE EXTINGUISHERS
-
-
3.1 'ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate )
fire extinguisher with fixing hangers, hose, brackets, screws to required size etc.,
complete as per IS:15683.
-
-
a) 6 Kg. Capacity
Each 38.00 5,400.00 205,200

307
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
3.2 CO2 gas type cylindrical shape fire extinguisher with fixing hangers, hose, brackets,
screws to required size etc.,complete as per IS:15683 - wall mounted type.

-
-
a) 4.5 Kg. Capacity
Each 38.00 12,575.00 477,850
-
3.3 CO2 type cylindrical shape fire extinguisher with hose and all required accessories,
complete as per IS:2878 - trolley mounted type for portable use.

-
-
a) 22.5 Kg. Capacity
Each 2.00 39,105.00 78,210
-
3.4 Aquous Film Forming Foam (AFFF) media cylindrical shape fire extinguisher with
gas cartridge, hose and all required accessories, complete as per IS:13386 - trolley
mounted type for portable use.
-
-
a) 50 Liters Capacity
Each 1.00 21,015.00 21,015
-
3.5 Providing and Fixing 3 Nos. G.I. sand buckets painted "Red Color" complete with G.I.
stand duly painted "Red Color" of suitable size to hang 3 Buckets at a time as per
required specifications.

Set 4.00 2,030.00 8,120


-
TOTAL C/O TO SUMMARY

790,395
-

308
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH 04 AUTOMATIC SPRINKLER SYSTEM
-
-
4.1 Pipes for Sprinkler System Branches/Headers
-
M.S. Black ERW Heavy grade "C Class" piping as per IS: 1239. The pipes being
suspended from ceilings by using supports complete with necessary specials such
as tees,bends, flanges, reducers, etc. Rate quoted shall include for painting of pipe
with a coat of primer and two coats of synthetic enamel paint of approved colour/
make for above ground piping as per the NBC / IS standards and local fire service
department requirement complete including supply and installation of installation of
G.I. threaded Rods, clamps , angle and fasteners etc., (M.S. Structural support i. e.
MS channel , plates if required, to be paid separately)
(Note : Pipes upto and including 50 mm dia shall be threaded joints, 65 mm
and above shall be welded joints.)
-
a) 150mm dia
Meter 280.00 1,665.00 466,200
b) 100mm dia
Meter 90.00 1,135.00 102,150
c) 80mm dia
Meter 160.00 870.00 139,200
d) 65mm dia
Meter 430.00 725.00 311,750
e) 50mm dia
Meter 320.00 600.00 192,000
f) 40mm dia
Meter 880.00 465.00 409,200
g) 32mm dia
Meter 110.00 415.00 45,650
h) 25mm dia
Meter 1,500.00 350.80 526,200
-
4.2 Providing, fixing, and testing of 15mm dia. Chrome finished sprinkler head with
standard response quartz bulb and to operate at 68°C (of Min K-Factor 5.6) complete
as per given specifications.(UL Listed/FM Approved)
-
a) Pendant/Upright (Standard Spray)
Each 680.00 390.00 265,200
b) Side wall Sprinklers (Standard Spray)
Each 460.00 590.00 271,400
c) Side wall Sprinklers (Extended Coverage Type) of required "K' factor.
Each 45.00 1,140.00 51,300
d) Concealed Type Sprinklers
Each 30.00 1,350.00 40,500
-

309
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
4.3 Extra over on above sprinkler item for providing chrome finished Rosette plate with
twin - piece recessed escutcheon plate, UL Listed / FM Approved, suitable for 15
mm size sprinklers.
Each 40.00 260.00 10,400
-
4.4 M.S. cabinet (size 600x450x150mm) fabricated from 16 gauge M.S. sheet with full
front glass door and locking arrangement with suitable shelves for keeping spare
sprinklers and one no. spanner properly fixed. Cabinet painted with enamel paint of
approved shade.
Each 1.00 3,290.00 3,290
-
4.5 Providing and fixing forged brass lever operated ball valve of full flow with forged
brass ball (Machined to mirror smooth finish with hard chrome plated) and spindle
with setting and gland of superior quality having minimum working pressure of 10
kg/cm2 etc. complete in all respect. (For Drain Valves)
-
-
a) 50 mm dia
Each 36.00 2,630.00 94,680
-
4.6 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, conforming to IS:13095
/ BS:5155. including matching flanges, gasket, nut & bolts etc.
-
a) 150 mm dia
Each 2.00 4,275.00 8,550
b) 80 mm dia
Each 32.00 2,985.00 95,520
c) 65 mm dia
Each 2.00 2,740.00 5,480
-
4.7 Providing and fixing 25 mm inspecting, testing and drain assembly for installation on
Sprinkler System, in brass body consisting of steel single lever 25 mm CP ball valve
for multiple test and drain functions, including inlet connection of specified size, 25
mm sight glass, connections to the main header and line drain complete as per
requirements. Product shall suitable for min. 10 kg/cm2 working pressure and shall
be UL Listed / FM Approved.
Each 36.00 5,910.00 212,760
-
4.8 Providing and fixing electrically operated flow indicating switches/water flow
detectors for indicating water flow in sprinkler branch line consisting of NEMA 4 rated
enclosure for vertical/horizontal mounting, to be installed as per manufacturer
specifications in an accessible location as per site, complete including wiring to
monitor modules as per instructions of the engineer-in-charge, for the below pipe
sizes.
-

310
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a) 80 to 150 mm Dia.
Each 36.00 5,195.00 187,020
-
4.9 Providing and fixing electrical Monitor Modules to monitor the water flow
devices/flows witches with built-in identification system indicating switches/water flow
detectors of 15-32v DC operating voltage to be installed as per manufacturer
specifications in an accessible location as per site, complete, excluding wiring to
Annunciation Panel, with UL/CE/LPCB approval.
Each 36.00 3,640.00 131,040
-
4.10 Providing and fixing electrical Fault-isolation Modules to protect the system against
wire to wire short circuits on loops, to be installed at the rate of after every 5 nos.
monitor modules complete as per manufacturer specifications and in an accessible
location as per site, excluding wiring to Annunciation Panel, with UL/CE/LPCB
approval.
Each 8.00 3,320.00 26,560
-
4.11 Providing and fixing intelligent-type Micro proccessor based Sprinkler Annunciation
Panel , compatible for seamless integration with waterflow devices, main fire alarm
panel and BMS systems (programmable outputs), with LCD type display & LED
indication for all zones, complete with internal sounder, alarm/fault indications &
standby 24v lead acid batteries with charger.
-
For minimum 72 zones (36 Working + 36 spare)
a) Each 1.00 184,620.00 184,620
-
4.12 Providing, fixing & pressure testing of flexible tubes stainless steel steel steel
braided type for connecting pendant sprinklers to branch lines, complete with all
necessary accessories, reducers, O-rings, nipples etc. of approved specifications &
make, complete with supporting structural arrangments in the false ceiling/slab as
per instructions of the engineer-in-charge, for the below lengths, as per the
reccommended lengths. -
For 700mm Length
a) Each 20.00 1,760.00 35,200
For 1000mm Length
b) Each 15.00 1,870.00 28,050
For 1500mm Length
c) Each 10.00 1,950.00 19,500
-
4.13 Providing,fixing and testing of 150mm dia alarm check valve with ACV trim set to
water motor alarm gong, retard chamber, UL Listed/FM approved, complete with
drain cock arrangement and with all accessories, welded or screwed as
required including cutting holes and chased in brick or RCC walls and making
good complete as per approved model.

Each 2.00 41,275.00 82,550

311
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
4.14 Providing and fixing heavy duty copper armored cables 1.1 KVA grade including
necessary support clamps at ceiling level and connection legs and double
compression glands,complete in all respects.

-
-
a) Control cable 2 core 1.5 Sq.mm
Metre 80.00 260.00 20,800
-
4.15 Providing, fixing, testing & commissioning of deluge valve with wet pilot trim
(Hydraulic Release) / electric release trim test and alarm rim complete with all
accessories viz. fittings, pressure gauge, valves, actuator, manifold etc. alarm gong
including up stream & down stream main header valve (for Pseudo
Compartmentation).
-
-
a) 80 mm dia
No. 2.00 63,975.00 127,950
-
4.16 Providing, fixing, testing and commissioning of 15 mm dia forged brass medium
velocity water spray open nozzle type sprinkler head (K-23, with an angle of 110
Degree) with a flow rate of 27.21 LPM and a pressure of 1.5 Kg/cm2. (Installation
shall be as per NFPA recommendation)
Each 40.00 355.00 14,200

-
TOTAL C/O TO SUMMARY

4,108,920

312
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATED COST OF EXTERNAL FIRE FIGHTING SERVICES

SUBHEAD AMOUNT IN INR


S.NO.

PIPES AND VALVES


SH-01
5,330,430

FIRE FIGHTING EQUIPMENTS & ACCESSORIES FOR INTERNAL HYDRANT


SH-02
SYSTEM 1,109,665

TOTAL CARRIED OVER TO SUMMARY


(SH01 + SH02 )
6,440,095

LESS 5% FOR UPRNN WORKING (322,005)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 6,118,090

313
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
XII FIRE FIGHTING SERVICES

SH 01. PIPES AND VALVES

1.1 Pipes for External Fire Fighting/Yard Hydrant System

M.S. Black ERW Heavy grade Class C piping as per IS: 1239. The pipes complete
with necessary specials such as tees, bends, elbows, flanges, reducers, etc. Rate
quoted shall include for painting of pipe with one coat of primer and two coats of
synthetic enamel paint of approved colour / make for aboveground piping and
coating & wrapping for underground piping as per the IS standards and local fire
service department requirements, complete in all respects.

(A) Underground piping with necessary flanges & fittings such as elbows, tees alongwith
pipe coating and wrapping of underground pipes with 4mm thick & 100mm wide
approved bitumen-based wrapping material. (Pypkote/Makpolycote) with overlap of
25mm (min) as per manufacturer's specification including trenching and backfilling
complete.

a) 150mm dia
R.M. 3,150.00 1,560.00 4,914,000
b) 100mm dia
R.M. 50.00 1,090.00 54,500
c) 80mm dia
R.M. 150.00 770.00 115,500
-
(B) Above ground piping with necessary flanges,fittings such as elbows, tees, supports,
angle, fastners and Painting with synthetic enamel paint two coats with one primer
coat as per the requirement of local fire service department.
-
a) 150mm dia
R.M. 10.00 1,665.00 16,650
b) 100mm dia
R.M. 10.00 1,135.00 11,350
c) 80mm dia
R.M. 70.00 870.00 60,900

-
1.2 Providing & fixing Sluice valve of CI body and brass non-rising type sprindle for PN
1.6 rating, conforming to IS:14846 with matching flanges , nut , bolts & rubber gasket
complete in all respects.
-
-

314
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a) 150mm dia
Each 7.00 13,020.00 91,140
-
1.3 Providing & fixing Non return valve of CI body for PN 1.6 rating, conforming to
IS:5312 with matching flanges, nut , bolts & gasket complete in all respects.
-
-
a) 150mm dia
Each 2.00 11,820.00 23,640
-
1.4 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, with matching flanges,
nut , bolts & gasket conforming to IS:13095/BS:5155.
-
-
a) 150mm dia
Each 10.00 4,275.00 42,750
-
1.5 Providing and fixing stainless steel fullway valve with wheel tested to 20 Kg/cm2 of
approved quality as per I.S:778. Class-II
-
-
a) 25 mm dia
Each 1,660.00 -
TOTAL C/O TO SUMMARY
5,330,430
-
SH -02 FIRE FIGHTING EQUIPMENTS & ACCESSORIES
-
-
2.1 FOR EXTERNAL YARD HYDRANT SYSTEM
-
-
2.1.1 Providing, fixing and testing of external fire hydrants with 63mm dia single outlets
and with instantaneous type male SS coupling for connection to hose conforming to
I.S:5290 Type-A (Oblique) inlets flanged, mounted on a 80mm dia stand post with
companion flanges, 1.6mm thick compressed asbestos gasket of approved
specifications and make, bolts, nuts and washers complete as per approved
design.The stand post to be tapped from the external ring, supported on a pedestal.

Each 32.00 6,910.00 221,120

315
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.1.2 Providing and fixing external fire hose box, wall mounting or free standing type,
made out of Mild Steel 16 SWG sheet, of approved colour of 30"x24"x10" size to
accommodate two 15m length of delivery hoses and a branch pipes with glass
fronted double door with lock and keys and break glass recess for keys, all
complete. (The sample to be approved before installations).
Each 32.00 5,460.00 174,720
-
2.1.3 Providing and fixing standard short size branch pipe with hand operated stainless
steel 20mm nominal bore outlet with standard instantaneous type 63mm dia
coupling as per IS: 903 complete as required.
-
-
a) stainless steel branch pipe
Each 32.00 2,595.00 83,040
-
2.1.4 Providing and fixing 63mm dia 15m long RRL - Reinforced rubberized fabric lined
hose including stainless steel male and female instantaneous type coupling approved
by fire authority, machine wound with copper wire complete in all respects hose to
IS:636 type-II and male, female coupling to IS: 903 with ISI certification. The Hose
shall be rated for burst pressure of 37.5 kg/ cm2

Each 64.00 7,015.00 448,960


-
2.1.5 Providing and fixing SS 4-way fire brigade inlet connection of 4 nos. 63mm dia
instantaneous type male coupling with built in check valves and 150mm dia flanged
outlet and 150 mm dia sluice valve complete with bolts, nuts and rubber insertions
as per I.S:904. (to be connected to static tank).
Each 3.00 58,075.00 174,225
-
2.1.6 Providing and fixing 100 mm dia fire brigade suction hose coupling (draw out
connection) with nut for female coupling as per I.S:902-1974 complete with 150mm
dia. suction pipe and 150 mm dia foot valve (To be connected to static tank)

Each 1.00 7,600.00 7,600


-
-
TOTAL C/O TO SUMMARY

1,109,665

316
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATED COST OF FIRE FIGHTING PUMPS & EQUIPMENTS

SUBHEAD AMOUNT IN INR


S.NO.

FIRE FIGHTING PUMPS & EQUIPMENTS


SH-01
5,360,221

LESS 5% FOR UPRNN WORKING (268,011)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 5,092,210

ESTIMATE COST OF FIRE FIGHTING PUMPS & EQUIPMENTS

SH 06. FIRE FIGHTING PUMPS

6.1 Fire Pumps & Accessories (Non DSR Items)

Supplying, installation, testing & commissioning of electric driven fire pumps


suitable for automatic operation consisting of the following (as per
specification).
Horizontal split casing single/ multistage, single/ multioutlet pumping set
complete with bronze impeller with C.I. body, SS shaft and sleeve and
connected by a flexible coupling, coupling gaurd to a tatally enclosed fan
cooled squirrel cage induction motor Mounted on common bed plate of
fabricated mild steel channel with cushy foot mounting with all pump
accessories complete as per specification including pressure gauges,
mechanical seal, lubricated grease bearing .

Motor to be suitable for 415V, 50Hz, AC supply of required H.P (or as per
pump efficiency) rating for the above pumps. Motor shall accept +/- 10%
variation in voltage and +/- 3% variation in frequency.

317
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Suitable reinforcement cement concrete pump foundation of 1:2:4 ratio (1
cement: 2 fine aggregate: 4 coarse sand) complete as per requirements
including foundation bolts, washers as required. foudation shall be finished
with a coat of neat cement with 50x50x3 mm thick M.S. angle edging and
foundation shall be painted with enamel paint.

(A) Main fire Pump

Type : Horizontal Split casing centrifugal suctiontype


Speed (rpm) : 1450
Capacity : 2280 lpm
Head : 125 m Set 1.00 452,080.00 452,080
-
(B) Jockey Pump
-
Type : Horizontal mounted centrifugal End suction type.
-
Speed (rpm) : 2900
-
Capacity : 180 lpm
-
Head : 125 m
Set 2.00 154,755.00 309,510

-
(A) Spinkler Pump
-
Type : Horizontal Split casing centrifugal suctiontype -
Speed (rpm) : 1450
-
Capacity : 2280 lpm
-
Head : 125 m
Set 1.00 452,080.00 452,080
-
(E) Water Curtain Pump
-
Type : Horizontal Split casing centrifugal suctiontype

318
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Speed (rpm) : 1450

-
Capacity : 1620 lpm

-
Head : 65 m

Each 1.00 326,035.00 326,035


-
6.2 Diesel Engine Driven Fire Pump
-
Supply, Installation, Testing and Commissioning of diesel engine driven stand
by pump suitable for automatic operation consisting of the following (as per
specification)

-
Horizontal split casing single/ multistage, single/ multioutlet pumping set with
CI body, bronze impleller, SS Shaft and sleeve and mechanical seal and
connected by means of a flexible coupling , coupling gaurd ,to a water
cooled diesel engine developing required BHP for the above pump
mounted on common bed plate of fabricated mild steel channel with cushy
foot mounting with all pump accessories, diesel engine starting panel for
starting of the lead acid 24V, 180 AH (including one spare battery) and
battery charger as per specification. Rate shall also include Exhaust pipe (
with properly insulation) of required length and size to discharge exhaust
gases externally, with muffler, day oil tank of 200 ltrs capacity with first charge
and hand pump set, including all internal cabling/piping as required for
commissioning. Fuel tank shall be of 4mm thick sheet, factory made and shall
have indication of low fuel switch, fuel level indicator, shut off nozzle and
audiable alarm in engine panel. -
Suitable reinforcement cement concrete pump foudation of 1:2:4 ratio (1
Cement: 2 Coarse Sand: 4 Coarse Aggregate) including foundation bolts,
washers as required. Foundation shall be finished with a coat of neat cement
with 50x50x3mm thick M.S angle edging and foundation shall be painted
with enamel paint. -
Type : Horizontal split casing centrifugal suction type. -
Capacity : 2280 LPM -
Head : 125 m -

319
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
RPM : 1600 (pump and engine) -
Mover : Diesel Engine. -
Material of Construction: -
Shaft & Sleeve : S.S. -
Impeller : Bronze -
Bearing : Grease, lubricated -
Seal - Mechanical seal. Set 1.00 956,700.00 956,700
-
6.3 Terrace Fire Pump
-
Supply, Installation, Testing and Commissioning of electric driven Terrace
Pump with required 415 volts , 3 phase 50 Hz .AC subitable DOL Starter Panel
of required rating and required electrical cable from motor to panel , panel
to pressure switch for terrace fire pump for automatic operation and
consistingof following : complete in all respect as required:
-
Horizontal type ,multistage, centrifugal split casing pump of cast iron, body &
bronze impeller with stainless steel steel steel shaft, mechanical seal and flow
of flow of 900 lpm at 35 M head conforming to IS 1520.
-
Suitable HP SQ cage induction motor TEFC type suitable for operation on 415
volts , 3 phase 50 Hz .AC with IP 55 class of protection for enclosure,
horizontal foot mounted type with Class- 'F' insulation, conforming to IS:325.
-
M.S fabricated Common base plate, coupling, coupling guard, foundation
bolts etc .as required .
-
Suitable cement concrete foundation duly plastered with antiviabration
pads.
Set 6.00 105,970.00 635,820

-
6.4 Providing motor control centres fabricated from 1.6 / 2 mm thick M.S. sheet
with powder coated finish. The control panels should be comparable with
H.P. of the motor as specified. -

320
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Panel for Fire Pumps
-
Fabricating, supplying, installation, testing & commissioning of totally
enclosed cubicle type fire pump control panel free standing, floor mounted,
comparatmentalised, sectionalised, dust ,dump and vermin proof with
suitable natural ventilation arrangement,front and rear accessible,lockable
power cum control panel, fabricated from 1.6/2 mm thick MS sheet (to give
IP 54 protection)spray painted with approved colour shade, heavy 4 strip
sleeved aluminium/ aluminium alloy bus bar, bus bar supports, inter
connecting from bus bars to out going switches/ MCCBs including earthing
the board suitable to accomodate the following including numbering etc. as
required. -
INCOMING:
-
a) 800amp. TP +NL M.C.C.B. with rotary handle of breaking capacity 35KA
-
b) One-Digital voltmeter with phase selection push button = 1Nos.
-
c) 3 Phase indicating lamps,instrument fuses and switches, 800 AMP AL.Bus
bar. -
-
BUS BARS OUTGOING
-
a) 400 Amp TPN BUS BAR (copper).
-
b) Two - 250 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity
35KA -
c) Two - 100 Amp.TP +NL M.C.C.B. with rotary handle of breaking capacity
35KA -

321
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
d) Two Fully Automatatic Star-Delta starters, 2 nos. suitable for 110 HP Pump
Motor with over load relay timer push buttons and Auto/Manual selector
switch and single phase preventer relay.

-
d) One Fully Automatatic Star-Delta starter, 1 no. suitable for 50 HP Pump
Motor with over load relay timer push buttons and Auto/Manual selector
switch and single phase preventer relay.

-
e) Eight Nos. Fully Automatic D.O.L Starter suitable for Jockey Pump, Terrace
Fire Pump Motor approx. 15 HP with over load relay, timer push buttons
and Auto/Manual selector switch and single phase preventer relay.

-
f) 11 nos. panel type Digital Amp. meters one for each motor with ASS. CTS
etc.
-
g) 11 sets of On/Off - neon indicating lamp for each pump

-
h) 1 set of Automatic Trip unit of suitable rating operating at 24V DC for Fully
Automatic Diesel engine starting system complete with battery charger, 8
window annunciator, indicating lights, transformer, rectifier, timer, voltmeter
ammeter, selector switches, push buttons, auxiliary relay etc. complete as
required as per NBC rules

-
i) All interconnecting power & control wires/cables suitable size within the
panel .
-
(All for above from item (a) to (i) complete set). (The shop drawing to be
prepared and approved before fabrication)
Set 1.00 541,205.00 541,205

322
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.5 PLANT ROOM PIPING
-
M.S. Black ERW Heavy grade class 'C' piping as per IS: 1239. The pipes being
suspended from ceilings by using supports complete with necessary specials
such as tees,bends, flanges, reducers, orifice plates etc. Rate quoted shall
include for painting of pipe with a coat of primer and two coats of synthetic
enamel paint of approved colour/ make for above ground piping as per
the TAC / IS standards and local fire service department requirement
complete including supply and installation of G.I. Rods, clamps, angle and ,
fasteners etc., (M.S. Structural support i.e. MS Channel, plate if required to be
paid separately). -
Above ground piping with necessary flanges and fittings such as elbows, Tees
and painting support and Orifice plates if any necessary for the system
complete as per the requiremet of local Fire Service Department.
-
a) 250mm dia (6.35 mm Thick )
R.M. 20.00 3,040.00 60,800
a) 200mm dia (6.35 mm Thick)
R.M. 20.00 2,440.00 48,800
b) 150mm dia R.M. 50.00 1,665.00 83,250
c) 100mm dia
R.M. 20.00 1,135.00 22,700
d) 80mm dia R.M. 20.00 870.00 17,400
6.6 Pressure Vessel for Fire Pump
-
Supply, Installation, Testing & Commissioning vertical air vessel fabricated
from 10 mm M.S. plate with dished ends from 12 mm M.S. plate, outside with
one coat of primer and two coats of synthetic enamel paint of approved
shade, complete with approved quality and air release valve, tripod type
stand, pressure gauge with ball valve, drain ball valve of 50mm dia with 2.0
meter long GI (Heavy Duty ) piping, 80 mm dia inlet complete as required
and all other required accessories to operate commonly main fire pump,
diesel fire pump and Jockey pump at drop of pressure, automatically at
required pressure setting; -
Recommended dia. : 450 mm
-
Height of shell : 2000 mm
-
Working pressure : 12 Kg/Sq.cm
-
Test Pressure : 18 Kg/Sq.cm
Each 7.00 33,225.00 232,575

323
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
6.7 Providing and fixing C.I double flanged "Y" type strainer with S.S. mesh,
including matching flanges, nuts, bolts and 3 mm thick gasket complete as
required. -
a) 200 mm dia
Each 2.00 55,725.00 111,450
b) 150 mm dia
Each 5.00 31,355.00 156,775
-
6.8 Providing & fixing Sluice valve of CI body and brass non-rising type sprindle
for PN 1.6 rating, conforming to IS:14846 with matching flanges,nut , bolts &
rubber gasket complete in all respects.
-
-
a) 200 mm dia
Each 4.00 22,555.00 90,220
b) 150 mm dia
Each 13,020.00 -
-
6.9 Providing & fixing Non return valve of CI body for PN 1.6 rating, conforming
to IS:5312 with matching flanges, nut , bolts & gasket complete in all
respects. -
-
a) 150mm dia
Each 1.00 11,820.00 11,820
b) 100mm dia
Each 4.00 7,590.00 30,360
c) 80mm dia
Each 2.00 5,360.00 10,720
-
6.10 Providing & fixing Butterfly valve with C.I. body & disc, stainless steel steel
steel/carbon steel shaft, Hand lever operated, PN 1.6 rating, with matching
flanges, nut , bolts & gasket conforming to IS:13095/BS:5155.
-
a) 200mm dia
Each 3.00 4,800.00 14,400
b) 150mm dia
Each 6.00 4,275.00 25,650
c) 100mm dia
Each 2.00 3,320.00 6,640
d) 80mm dia
Each 2.00 2,985.00 5,970

324
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
6.11 Providing and fixing flanged flexible connectors (expension bellows) in SS 304
braiding, of rating PN 1.6 or equivalent, to provide stress relief for
suction/delivery of pumps, complete with standard matching flanges, nuts,
bolts etc. -
a) 200mm dia
Each 3.00 7,085.00 21,255
b) 150mm dia
Each 4.00 5,555.00 22,220
c) 100mm dia
Each 3.00 2,230.00 6,690
d) 80mm dia
Each 2.00 2,105.00 4,210
-
6.12 Providing and fixing pressure switch (for operation at 0-15 Kg./sqcm) with
required fittings and accessories complete for all pumps.
-
a) Standard type Each 12.00 5,055.00 60,660
-
6.13 Providing and fixing heavy duty copper armored cables 1.1 KVA grade
including necessary support clamps at ceiling level and connection legs and
double compression glands,complete in all respects.
-
a) Control cable 6 core 1.5 Sq.mm
Metre 250.00 435.00 108,750
b) Control cable 4 core 1.5 Sq.mm Metre 500.00 350.00 175,000
-
6.14 Providing and fixing heavy duty Aluminum armored cables 1.1 KVA grade
including necessary support clamps at ceiling level, connection lugs and
double compression glands, complete in all respects.
-
a) Power cable 3 core 35 Sq.mm
Metre 30.00 505.00 15,150
b) Power cable 3 core 95 Sq.mm
Metre 100.00 970.00 97,000
c) Power cable 3.5 core 120 Sq.mm
Metre 100.00 1,345.00 134,500
-
6.15 Providing Earthing station for pumps and MCC panel including excavation
with copper plate earth 600 mm x 6mm thick including accessories and
providing masonry enclosure with cover plate having locking arrangement
and 40mm dia watering pipe etc, with charcoal or coke and salt complete
as required. Each 1.00 3,230.00 3,230
-

325
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
B) Fire Pumps & Accessories (DSR Items)
-
6.16 ELECTRIC Supplying and fixing of following powder coated perforated type cable tray
AL DSR system including fittings and accessiores on existing structural supports,
4.1 fabricated from min. 2mm thick CRCA MS sheets inluding the cost of powder
coatings of approved shade of min. 50 micron film thickness on MS surface
cleaned and perepared twith 7 tank process and including the cost of
provinding loop earthing with 2 nos. 25mm x 6mm GI earth strips complete as
per specifications and inluding the cost of approved arrangement of cable
tray hangers fabricated from galvanized MS angles/flats/rods including jointg
the steel section of the suupport arrangement with nuts and bolts/welding
and including securing the support to the structural ceiling by dash fasteners
etc.complete with spacing of 600mm for 900mm/1200mm and 750mm for
lower sizes, as required, and as below. -
a) 300mm x50mmx1.60mm trays
Metre 50.00 789.00 39,450
b) 150mmx50mmx1.60mm trays
Metre 50.00 520.00 26,000
-
6.17 ELECTRIC Supplying and laying of 8 guage GI wire for Earthing including connections
AL DSR as per specification and /or as per direction of Project in-charge.
5.16 Metre 100.00 35.00 3,500
-
6.18 ELECTRIC Providing and fixing Pressure gauge (0-14 Kg/Cm2) with necessary ball /
AL DSR isolation valve and fittings such as tees, elbows and painting and supports
16.8 etc. complete. -
a) 100mm dia Each 12.00 958.00 11,496
-
6.20 ELECTRIC Providing and fixing 25mmx5mm GI strip in 40mm dia GI pipe from earth
AL DSR electrode as required.
5.11
Metre 50.00 421.00 21,050
-
6.21 ELECTRIC Providing and fixing 25mmx5mm GI strip in on surface (or) in recess for earth
AL DSR connection etc as required.
5.15 Metre 50.00 142.00 7,100

TOTAL C/O TO SUMMARY


5,360,221

326
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DETAILED COST ESTIMATE, ELECTRICAL WORKS

5 GRAND SUMMARY OF COST

HEAD ESTMATED
S.NO. AMOUNT IN INR

BLOCKS
A.

ACADEMIC & ADMIN BLOCK


5.01 102,622,005
HOSTEL BLOCK
5.02 39,665,905
RESIDENTIAL BLOCK-1 &2
5.03 31,213,801
RESIDENTIAL BLOCK-3 &4
5.04 35,691,032
HIGH SIDE
5.05 131,237,790
MISCELLANEOUS BUILDINGS
5.06 15,023,696
SUB TOTAL (A)
355,454,229

327
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY OF COST (ACADEMIC & ADMIN BLOCK)

SUBHEAD OF WORKS
SUBHE AD ESTIMATED
NO AMOUNT OIN INR

ACADEMIC & ADMIN BLOCK


A.

SH-01 POINT WIRING AND ACCESSORIES: 20,236,993

SH-02 MV PANELS & DISTRIBUTION BOARDS 6,558,324

SH-03 EARTHING SYSTEM 2,997,154

SH-04 LIGHTNING PROTECTION SYSTEM 690,416

SH-05 LIGHT FIXTURES AND FANS: 31,870,378

SH-06 TELEPHONE SYSTEM 4,082,623

SH-07 FIRE ALARM SYSTEM 23,201,130

SH-08 DATA NETWORKING (13334285 + 1577500 + 750000) 15,661,785

SH-09 TV System 2,724,360


SUB TOTAL (A) 108,023,163

LESS 5% FOR UPRNN WORKING (5,401,158)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 102,622,005

328
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATECOST OF ELECTRICAL WORKS: ACADEMIC & ADMIN BLOCK

POINT WIRING AND ACCESSORIES:


SH-01

1.00 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable in surface /
DSR - 1.3 recessed steel conduit, with modular switch, modular plate, suitable GI box
and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper
conductor single core cable etc as required.

a. DSR-1.3.3 Group C
Point 1,248.00 1,003.00 1,251,744

2.00 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed steel conduit, 2 way
DSR - 1.4 modular switch, modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as
required. Point 50.00 1,069.00 53,450

3.00 Wiring for circuit/ submain wiring along with earth wire with the following sizes
of FRLS PVC insulated copper conductor, single core cable in surface/
DSR -1.7
recessed steel conduit as required

b 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire


DSR - 1.7.2
Metre 1,625.00 200.00 325,000
c 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
DSR - 1.7.3
Metre 800.00 231.00 184,800
d 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
DSR - 1.7.4
Metre 800.00 315.00 252,000

329
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
4.00 Wiring for light/power plug with 2X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
DSR – 1.12 along with 1 no. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required. (UPS Power)
Metre 26,000.00 162.00 4,212,000

5.00 Wiring for light/power plug with 2X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
DSR – 1.12 along with 1 no. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required. (RawPower)
Metre 22,500.00 162.00 3,645,000

6.00 Wiring for light/power plug with 4X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
DSR – 1.13 along with 2 nos. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required. (UPS Power)
Metre 1,850.00 275.00 508,750

7.00 Wiring for light/power plug with 4X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
DSR – 1.13 along with 2 nos. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required. (RawPower)
Metre 9,000.00 275.00 2,475,000

8.00 Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes
of FRLS PVC insulated, copper conductor,single core cable in
DSR – 1.14
surface/recessed medium class PVC conduit as required.

a DSR – 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire


1.14.1 Metre 15,400.00 106.00 1,632,400
b DSR – 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
1.14.2 Metre 1,500.00 131.00 196,500
c 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
DSR-1.14.3
Metre 400.00 162.00 64,800
d 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
DSR-1.14.4
Metre 800.00 221.00 176,800

9.00 Supplying and drawing following sizes of FRLS PVC insulated copper
DSR-1.17 conductor, single core cable in the existing surface/ recessed steel/ PVC
conduit as required.

330
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a 1 x 1.5 sq. mm
DSR-1.17.1
Metre 500.00 22.00 11,000
b 2x 1.5 sq. mm
DSR-1.17.2
Metre 400.00 36.00 14,400
c 3x 1.5sq. mm
DSR-1.17.3
Metre 300.00 50.00 15,000
d 4x 1.5 sq. mm
DSR-1.17.4
Metre 250.00 63.00 15,750
k DSR- 2 x 2.5 sq. mm
1.17.11 Metre 100.00 53.00 5,300
t DSR- 2 x 4 sq. mm
1.17.20 Metre 100.00 77.00 7,700
u DSR- 2 x 4 sq. mm
1.17.21 Metre 100.00 109.00 10,900

10.00 Supplying and fixing of following sizes of steel conduit along with accessories
in surface/recess including painting in case of surface conduit, or cutting the
DSR-1.20 wall and making good the same in case of recessed conduit as required.

a 20 mm
DSR-1.20.1
Metre 100.00 121.00 12,100
b 25 mm
DSR-1.20.2
Metre 300.00 142.00 42,600
c 32 mm
DSR-1.20.3
Metre 100.00 193.00 19,300
d 40 mm
DSR-1.20.4
Metre 100.00 287.00 28,700
e 50 mm
DSR-1.20.5
Metre 50.00 387.00 19,350

11.00 Supplying and fixing of following sizes of medium class PVC conduit along
DSR-1.21 with accessories in surface/recess including cutting the wall and making
good the same in case of recessed conduit as required.

331
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a DSR-1.21.1 20 mm
Metre 300.00 53.00 15,900
b DSR-1.21.2 25 mm
Metre 1,000.00 65.00 65,000
c DSR-1.21.3 32 mm
Metre 700.00 85.00 59,500
d DSR-1.21.4 40 mm
Metre 200.00 110.00 22,000
e DSR-1.21.5 50 mm
Metre 150.00 144.00 21,600

12.00 Supplying and fixing metal box of following sizes (nominal size) on surface or
DSR-1.22 in recess with suitable size of phenolic laminated sheet cover in front
including painting etc as required.
a DSR-1.22.1 75 mm X 75 mm X 60 mm deep
Each 200.00 89.00 17,800
c DSR-1.22.3 150 mm X 75 mm X 60 mm deep
Each 50.00 111.00 5,550
d DSR-1.22.4 150 mm X150 mm X 60 mm deep
Each 200.00 160.00 32,000

13.00 Supplying and fixing following modular switch/ socket on the existing
DSR-1.24 modular plate & switch box including connections but excluding modular
plate etc. as required.

a DSR-1.24.1 5/6 amps switch


Each 2,000.00 81.00 162,000
b DSR-1.24.2 2 way 5/6 amps switch
Each 35.00 96.00 3,360
c DSR-1.24.3 15/16 amp switch
Each 679.00 111.00 75,369
d DSR-1.24.4 3 pin 5/6 amp socket outlet
Each 1,986.00 79.00 156,894
e DSR-1.24.5 6 pin 15/16 amp socket outlet
Each 679.00 150.00 101,850
f DSR-1.24.6 Telephone socket outlet
Each 394.00 95.00 37,430
g DSR-1.24.7 TV antenna socket outlet
Each 61.00 94.00 5,734
h DSR-1.24.8 Bell push
Each 10.00 111.00 1,110

14.00 S/F Modular Type Blanking Plate : Supplying and fixing modular blanking
DSR - 1.26 plate ,on the existing modular plate & switch box excluding modular plate
etc. as required.
Each 100.00 23.00 2,300

332
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.00 S/F GI Box along with modular plate: Supplying and fixing following size
DSR – 1.27 /modules, GI box along with modular base & cover plate for modular
switches in recess etc as required.

a DSR – 1 or 2 Module(75mmx75mm)
1.27.1 Each 3,179.00 166.00 527,714
b 3 Module (100mmX75mm)
DSR-1.27.2
Each 2,665.00 175.00 466,375
c 4 Module (125mmX75mm)
DSR-1.27.3
Each 60.00 195.00 11,700

16.00 Supply & fixing following modular base and cover plate for modular
DSR - 1.28 switches in recess etc as required.

a DSR - 1 or 2 Module
1.28.1 Each 3,179.00 79.00 251,141
b DSR - 3 Module
1.28.2 Each 2,665.00 88.00 234,520
c DSR - 4 Module
1.28.3 Each 60.00 97.00 5,820

17.00 Supplying and fixing 3 pin, 5 amp ceiling rose ,on the existing junction box
DSR - 1.33 including connection etc. as required.
Each 1,000.00 43.00 43,000

18.00 Supplying and fixing brass batten/angle holder including connection etc. as
DSR - 1.34 required.
Each 150.00 74.00 11,100

19.00 Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
DSR - 1.36 including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.
Each 400.00 163.00 65,200

333
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
20.00 Supplying and fixing stiff pendent with 600 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
DSR - 1.37
including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.

Each 200.00 163.00 32,600

21.00 Supplying and fixing call bell/ buzzer suitable for single phase,230 Volts,
DSR - 1.38 complete as reqired.
Each 10.00 61.00 610

22.00 Providing and fixing 16/0.20mm (0.50sqmm) twin flat flexible,FRLS PVC
insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or
DSR - 1.39 side of the table/ door etc. as required.

Each 200.00 21.00 4,200

23.00 Providing and fixing 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC
insulated, PVC sheathed copper cable direct on the wall with PVC clips etc.
DSR - 1.40 . as required.

Each 200.00 19.00 3,800

24.00 Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug
DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
minus1.20. insulated, copper conductor single core cable for loop earthing as
1) required.(UPS Power)
Metre 5,200.00 107.00 556,400

25.00 Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug
DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
minus1.20.
insulated, copper conductor single core cable for loop earthing as
1)
required.(RawPower) Metre 10,940.00 107.00 1,170,580

334
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
26.00 Wiring for the following light points with 1.5 sq.mm PVC insulated
copper conductor 1100 volts grade stranded flexible FRLS wires of
approved make in concealed or surface mounted 25 mm dia medium
DRDSR class PVC conduit controlled by SPMCB provided in the DB and earthing of
fixtures with 1.5 sq.mm PVC insulated copper conductor stranded flexible
FRLS wire.(Cost of MCB not to be included here)

a One point controlled by one MCB.


Points 105.00 228.00 23,940
b Two points controlled by one MCB.
Points 52.00 456.00 23,712
c Three points controlled by one MCB.
Points 75.00 684.00 51,300
d Four points controlled by one MCB.
Points 60.00 912.00 54,720
e Five points controlled by one MCB
Points 135.00 1,140.00 153,900
f Six points controlled by one MCB.
Points 80.00 1,368.00 109,440
g Seven points controlled by one MCB.
Points 60.00 1,596.00 95,760
h Eight points controlled by one MCB.
Points 10.00 1,824.00 18,240
I Nine points controlled by one MCB.
Points 115.00 2,052.00 235,980
j Ten points controlled by one MCB.
Points 25.00 2,280.00 57,000

27.00 Supplying and fixing 250x150x75 mm deep, 1.6 mm thick G I Junction box
NON DSR with coverplate complete as per site requirement.
Nos 125.00 500.00 62,500
TOTAL FOR SH-1 - POINT WIRING AND ACCESSORIES:
- 20,236,993

SH-02 MV PANELS & DISTRIBUTION BOARDS


1.00 Providing and fixing following rating and breaking capacity MCCB in existing
cubicle panel board including drilling holes in cubicle panel, making
DSR - 2.2
connections, etc. as required.

335
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a 100 Amp, 16 KA, TP MCCB
DSR - 2.2.1
Each 3.00 3,205.00 9,615
b 200 Amp, 25 KA , TP MCCB
DSR - 2.2.5
Each 3.00 8,814.00 26,442
c 400 Amp, 35 KA , TP MCCB
DSR - 2.2.9
Each 2.00 17,372.00 34,744

2.00 DSR - 2.3 S/F prewired SP MCB DB : Supplying and fixing following way single pole and
neutral,sheet steel MCB distribution board 240 volt,s on surface/recess,
complete with tinned copper bus bar , neutral bus bar , earth bar , din bar ,
interconnections , power painted including earthing etc. as required .(But
without MCB/RCCB/Isolator ).
a DSR - 2.3.5 2+4 way /6 Way ,Double Door Each 923.00
2.00 1,846
b DSR - 2.3.7 2+8 Way / 10 way,Double Door Each 1,132.00
6.00 6,792

3.00 S/F prewired TP MCB DB : Supplying and fixing following way prewired TP&N
MCB distribution board of steel sheet for 415 volts on surface/recess,
complete with loose wire box, terminal connectors for all incoming and
DSR - 2.8 outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper
conductor up to terminal blocks , tinned copper bus bar , neutral link , earth
bar , din bar , detachable gland plate , interconnections , power painted
including earthing etc. as required .(But without MCB/RCCB/Isolator ).

a 4 way (4 + 12 ),Double Door


DSR – 2.8.5
Each 3.00 7,357.00 22,071
b 8 way (4 + 24 ),Double Door
DSR – 2.8.7
Each 47.00 10,405.00 489,035
c 12 way (4 + 36 ), Double Door (LPDB)
DSR – 2.8.8
Each 48.00 12,782.00 613,536

336
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
4.00 S/F vertical type prewired Vertical Type MCB DB : Supplying and fixing
following way prewired Vertical Type TP&N MCB distribution board of steel
sheet for 415 volts on surface/recess, complete with loose wire box of sheet
steel, dust protected, duly powder painted, inclusive of 200 amps tinned
copper bus bar, common neutral link, earth bar , din bar for mounted MCB's,
DSR - 2.9 terminal connectors for all incoming and outgoing circuits, duly prewired
with adequate size of FRLS PVC insulated copper conductor upto the
terminal connector/neutral link, earthing etc. as required .(But without
MCB/RCCB/Isolator ). (Note: Prewired vertical type MCB TPDB is normally used
where 3 phase outlets are required.)

a 4 Way Double Door


DSR - 2.9.5
Each 5.00 7,901.00 39,505
b 8 way Double door
DSR - 2.9.7
Each 5.00 11,123.00 55,615

5.00 S/F 'C' Curve , SP MCB : Supplying and fixing 5 amps to 32 amps, rating,
240/415 volts, 'C' Curve , miniature circuit breaker suitable for inductive load
DSR - 2.10 of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.

a DSR - Single Pole


2.10.1 Each 2,731.00 169.00 461,539
b DSR - Single Pole and Neutral
2.10.2 Each 100.00 441.00 44,100

6.00 S/F SP MCB blanking plate : Supplying and fixing single pole blanking plate in
DSR - 2.11 the existing MCB DB complete etc.as required.
Each 20.00 7.00 140

7.00 S/F DP MCB isolator : Supplying and fixing following rating, double pole , 240
DSR - 2.12 volts, isolator in the existing MCB DB complete with connections, testing and
commissioning etc. as required.

a DSR - 40 amps
2.12.1 Each 8.00 218.00 1,744

337
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.00 S/F FP MCB isolator : Supplying and fixing of following rating, four pole , 415
volts, isolator in the existing MCB DB complete with connections, testing and
DSR - 2.13
commissioning etc. as required.

a DSR - 40 amps
2.13.1 Each 50.00 659.00 32,950
b DSR - 63 amps
2.13.2 Each 53.00 670.00 35,510

9.00 S/F SPN RCCB :Supplying and fixing following rating, double pole, (single
phase and neutral), 240 volts, residual current circuit breaker (RCCB), having
DSR - 2.14 a sensitivity current upto 300 milliamperes in the existing MCB DB complete
with connections, testing and commissioning etc. as required.

a DSR - 25 amps
2.14.1 Each 126.00 1,645.00 207,270
b DSR - 40 amps
2.14.2 Each 270.00 1,714.00 462,780

10.00 Supplying and fixing following rating, four pole, (three phase and neutral),
415 volts, residual current circuit breaker (RCCB), having a sensitivity current
DSR - 2.15 upto 300 milliamperes in the existing MCB DB complete with connections,
testing and commissioning etc. as required.

a DSR - 40 amps
2.15.2 Each 5.00 1,714.00 8,570
b DSR - 63 amps
2.15.3 Each 5.00 2,237.00 11,185

11.00 Supplying and fixing DP sheet steel enclosure on surface/ recess along with
16/25/32amps 240 volts "C" curve DP MCB complete with connections, testing
DSR - 2.16
and commissioning etc. as required.
Each 20.00 617.00 12,340

338
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
12.00 Supplying and fixing TP sheet steel enclosure on surface/ recess along with
DSR - 2.17 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing
and commissioning etc. as required.
Each 20.00 868.00 17,360

13.00 S/F 20 A SPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 240
Volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed
plug top along with 20 Amps, C-Curve, SP MCB, in sheet steel enclosure, on
DSR - 2.18
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 50.00 954.00 47,700

14.00 S/F 20 A TPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
DSR - 2.19
plug top along with 20 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 10.00 1,967.00 19,670

15.00 S/F 30 A TPN MCB industrial socket outlet : Supplying and fixing 30 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 30 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
DSR - 2.20
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 5.00 2,473.00 12,365

339
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
16.00 Supplying,Installation, testing and commissioning of cubical type LT panel
suitable for 415V, 3 Phase,4 wire 50 Hz AC supply system fabricated in
compartmentalized design from CRCA sheet steel of 2mm thick for frame
work and covers, 3mm thick for gland plates i/c cleaning & finishing
completed 9 tank process of powder coating in approved shade,having
extensible type TPN Aluminium alloy bus bars of high conductivity,DMC/SMC
bus bar supports,with short circuit withstand capacity for 1 sec, bottom base
channel of MS section not less that 100 mm x 50mm x 5mm thick, fabrication
shall be done transportable sections,entire panel shall have a common
copper earth bar of size 25mmx5mm at the rear with 2 no's earth stud,solid
connections from main bus bar to switchgears with required size of
alunimium bus bars and control wiring PVC insulated copper conductor S/C
cable alleys,cable gland plates in two half,i/c providing following switch
gears: (with all necessary hardware, accessories as required for complete
installation as per specifications and single line digram).

Refer CPWD general specification for Electrical works Part IV Sub station

Note: 1.Provision for both Bottom & Top cable entry shall be provided in All
Panels .

All panles shall be indoor type unless otherwise mentioned. Only feeder pillers
shall be outdoor type.

MV PANELS

General Notes:

A. ACB:

i LSIG (Microprocessor Based) releases shall be used for incoming feeders such
as Transformers and DG Sets & LSI releases for outgoing breakers. All ACB
shall have Icu = Ics = Icw for 1 Second.

340
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ii All 4 Pole ACB shall have fully Rated neutral equal to rating of the breaker &
shall be protected against overload & short-circuit .

iii Ready-to-close contact shall exist for indicating that all safety parameters
are checked & enabling closure of breaker, ensuring at-most safety for the
user

iv A door interlock shall be provided so that it shall not be possible to open the
door until the air circuit breaker moving part is in the disconnected position.

B. MCCB:

i. All MCCBs shall be suitable for 3 Phase 415 Volts AC 50 HZ supply

ii. All MCCBs shall have rated service breaking capacity (Ics) equal to the
ultimate breaking capacity (Icu) at defined operational voltage.

iii. All MCCBs shall clearly indicate the suitability for isolation in the name plate
identified by the symbol

iv. All MCCBs shall offer class –II front face i.e. main current path of the circuit
breaker should be isolated from auxiliary section

v. All Incomer MCCBs shall be provided with earth fault protection

vi. MCCBs of above250A Microprocessor Based and upto 250A thermal


Magnetic releases.

vii. This BOQ to be read in conjunction with technical specifications and Single
Line Diagram (attached for reference). If any discrepancy occurs that should
be brought to the notice of Client/Consultant before quoting the price
otherwise stringent condition will be deemed to have been considered.

341
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

viii. All ACBs to be provided with ON/OFF/Trip lamps, 3 NO + 3NC Auxiliary


contacts other than used in control circuit.

ix. All Transformer and DG incoming ACBs shall be provided with Microprocessor
based releases & ON/OFF/Trip / Spring charged/ready to close indicating
lamps.

x. All MCCBs shall be provided with rotary operating handle and ON/OFF lamps
backed by 2Amp control MCB.

xi. All meters shall be digital type (unless otherwise specified)

xii. Multi-function meter to be provided as required to cover all the parameters


as mentioned.

xiii. All current/voltage transformer shall be cast resin type.

xiv. All indicating lamps shall be LED type.

xv. Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus
bar is after considering all derating factors. (Bus bar sizing calculation to be
submitted for approval.)

xvi. All internal control wiring shall be heat resistant type.

xvii. All incoming breakers in Main LT panel shall be electrically interlocked.

xviii. All TP feeders shall be provided with Isolable neutral link.

xix. Bus bar chamber shall be provided at top only. Incoming and outgoing
cable entry shall be from top/bottom as required.

xx. Bus couplers in Main MV Panel shall be Microprocessor based with all
releases.

342
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

xxi. Bus couplers shall be provided with ON & OFF indicating lights but without
releases.

xxii. All feeders shall be provided with door interlocked with door defeat, pad
lock facility.

xxiii. Live parts shall not be accessible after opening the door, Transparent acrylic
sheet to be provided to cover the same.

xxiv. Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto
terminal block.

xxv. 20% spare control terminal to be provided.

xxvi. All MCCBs shall be provided with variable O/L & S/C releases. Incoming
MCCB shall be provided with E/F releases also

xxvii. All incoming/outgoing cables shall be terminated on links/terminals.

xxviii. All Panels shall have 100 % Neutral Bus Bar Rating.

xxix. Degree of protection for following type of distribution panel enclosure shall
be as per IS: 13947-1993.

IP 43 for indoor panels.

IP 55 for outdoor panels.

xxx. Painting/lettering on Breakers and distribution boards, the location they


serve, providing on each panel its circuit diagram.

343
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
16.01 ACADEMIC BLOCK PANELS
16.01.1 Non DSR MAIN LT PANEL (ACADEMIC BLOCK)

Incomer (2 Nos.)

1000A 4P MDO ACB,50 KA(microprocessor based )

Note : Mechanical Interlocking shall be provided between two incomers.

Metering & Indication:

Each Shall have

Multifunction Digital meter (consisting of Voltage, Amps, kWh, kW, P.F.


parameter) with RS 485 Port.

Breaker ON / OFF / TRIP indicating lights with control MCB’s.

Set of RYB phase indicating lamps with 2A control MCBs.

Busbar

1250A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).

Outgoings:

Set of RYB phase indicating lamps with 2A control MCBs on each outgoing
to be provided.

Each Outgoing shall be provided with 3-phase digital type energy meters
with Communication Port.

Three(3) Nos. 400 A TP MCCB (25KA)

Three(3) Nos. 250 A TP MCCB (25KA)

Two (2) Nos. 200 A TP MCCB (25KA)

Thirty(30) Nos. 100 A TP MCCB (25KA)


Set 1.00 1,598,500.00 1,598,500

344
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

16.01.2 MDB (Typical)


Non DSR Location : Respective Floor

Incomer (1 No.)

100A TP+N MCCB,25 KA

Metering & Indication:

(0-500) volts digital voltmeter with selector switch protected by 2A control


MCB's

(0-100A) Digital ammeter with Selector Switch and 100/5 amps , Cl-1, 5VA CT's

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Busbar

160A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).

Outgoings:

- Two (2) Nos. 40A DP MCB (10KA)

- Four (4) Nos. 63A 4P MCB (10KA)


Sets 18.00 70,800.00 1,274,400

345
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
16.01.3 Basement MDB : (Typical For Terrace MDB)
Non DSR Location Respective Floor

Incomer (1 No.)

100A TP+N MCCB,25 KA

Metering & Indication:

(0-500) volts digital voltmeter with selector switch protected by 2A control


MCB's

(0-100A) Digital ammeter with Selector Switch and 100/5 amps , Cl-1, 5VA CT's

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Busbar

160A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).

Outgoings:

-
- Seven (7) Nos. 63A 4P MCB (10KA)
Sets 2.00 77,800.00 155,600

16.01.4 Non DSR UPS Panel(Academic Block)

Incomer (2 Nos.)

250A 4P MCCB,25 KA

Metering & Indication:

346
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Multifunction Digital meter (consisting of Voltage, Amps,KWH,KW, P.F.,Total
Harmonic Distortion parameter) with RS 485 Port.
Breaker ON / OFF / TRIP indicating lights with control MCB’s.

Set of RYB phase indicating lamps with 2A control MCBs.

Busbar

400A, TP+2N Copper, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).

Outgoings:

Set of RYB phase indicating lamps with 2A control MCBs on each outgoing
to be provided.

Forty(40) Nos. 63 A 4P MCB (10KA)


Set 1.00 451,600.00 451,600

16.01.5 Non DSR


Lift Panel (Tower LHS & RHS)

Incoming (1 No.):

100Amp TP+N MCCB, 25kA

Metering & Indication:

(0-500) volts digital voltmeter with selector switch protected by 2A control


MCB's

(0-100A) Digital ammeter with Selector Switch and 100/5 amps Cl-1, 5VA CT's

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

347
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Bus Bars:

160A, TPN aluminium , colour coded Sleeved bus bars suitable for 415V, 50Hz.
(after deration)

Outgoings

Phase indicating lamps with 2A Control MCB shall be provided on each


outgoing.

1 Nos. 40A 4P MCB (10 KA)

3 Nos. 40A 4P RCBO (30 mA,10 KA)


Set 2.00 84,900.00 169,800

16.01.6 Non DSR Lift Panel (Central Dome)

Incoming (1 No.):

63 Amp TP+N MCCB, 25kA

Metering & Indication:

(0-500) volts digital voltmeter with selector switch protected by 2A control


MCB's

(0-60A) Digital ammeter with Selector Switch and 60/5 amps Cl-1, 5VA CT's

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:

160A, TPN aluminium , colour coded Sleeved bus bars suitable for 415V, 50Hz.
(after deration)

348
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Outgoings

Phase indicating lamps with 2A Control MCB shall be provided on each


outgoing.

1 Nos. 40A 4P MCB (10 KA)

2 Nos. 40A 4P RCBO (30 mA,10 KA)


Set 1.00 78,500.00 78,500

17.00 S/F 63 A TPN MCB industrial socket outlet : Supplying and fixing 63 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 63 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
Non DSR
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 2.00 6,500.00 13,000

18.00 S/F 20 A SPN MCB socket outlet : Supplying and fixing 20 Amps, 240 Volts,
SPN, socket outlet, with 2 pole and earth , plug top along with 20 Amps, C-
Curve, SP MCB, in weather proof enclosure/Floor Junction Box, on surface or
Non DSR
in recess, complete with connections, testing and commissioning etc. as
required.(Weather Proof Type)
Each 5.00 4,500.00 22,500

19.00 S/F 20 A TPN MCB socket outlet : Supplying and fixing 20 Amps, 415 Volts, TPN,
industrial type socket outlet, with 4 pole and earth along with 20 Amps, C-
Curve, TPN MCB, in weather proof enclosure/Floor Junction Box, on surface
Non DSR
or in recess, and complete with connections, testing and commissioning etc.
as required. (Weather Proof Type)
Each 20.00 5,500.00 110,000

20.00 Supply & Fixing of Four Pole 63 A Manual Change over Switch with Powder
Non DSR Coated Matalic Encloser as required.
Each 2.00 5,000.00 10,000

TOTAL FOR SH-2 - MV PANELS & DISTRIBUTION BOARDS:


6,558,324

349
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-03 EARTHING SYSTEM

1.00 G.I. earth plate electrode : Earthing with GI earth plate 600mm X 600mm X 6
mm thick including accessories and providing masonary enclosure with
DSR - 5.4 cover plate having locking arrangement and watering pipe of 2.7 metre
long etc. with charcoal/coke and salt as required.
Set 12.00 4,490.00 53,880

2.00 Copper earth plate electrode : Earthing with Copper earth plate 600mm X
600mm X 3 mm thick including accessories and providing masonary
DSR - 5.6 enclosure with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/coke and salt as required.
Set 22.00 9,292.00 204,424

3.00 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground
as strip earth electrode, including connection/ terminating with G.I. nut, bolt,
DSR - 5.8 spring, washer etc. as required. (Jointing shall be done by overlapping and
with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Metre 400.00 753.00 301,200

4.00 Supplying and laying 25mm x 5 mm GI strip at 0.50 m below ground as strip
earth electrocde, including connection/terminating with G.I. nut, bolt, spring,
DSR - 5.9 washer etc. as required. (Jointing shall be done by overlapping and with 2
sets of G.I nut bolt & spring washer sapced at 50mm).
Metre 4,000.00 109.00 436,000

5.00 Providing & Fixing 25mm x 5 mm Copper strip in 40 mm dia G.I. Pipe from
DSR - 5.10
earth electrode including connection with brass nut, bolt, spring, washer
excavation and re-filling etc. as required.
Metre 100.00 1,082.00 108,200

6.00 Providing & Fixing 25mm x 5 mm G.I. Strip in 40 mm dia G.I. pipe from earth
electrode including connection with G.I. nut, bolt, spring, washer excavation
DSR - 5.11
and re-filling etc. as required.
Metre 100.00 421.00 42,100

7.00 Providing and laying earth connection from earth electrode with 6 SWG dia
DSR - 5.12 G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection
with G.I. thimble excavation and re-filling as required.
Metre 200.00 151.00 30,200

350
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.00 Providing and fixing 25mm X 5mm Copper strip on surface or in recess for
DSR - 5.14 connections etc. as required.
Metre 50.00 856.00 42,800

9.00 Providing and fixing 25mm X 5mm GI strip on surface or in recess for
DSR - 5.15 connections etc. as required.
Metre 50.00 142.00 7,100

10.00 Providing and fixing 6 SWG dia GI wire on surface or in recess for
DSR – 5.16 connections etc. as required.
Metre 100.00 35.00 3,500

11.00 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for
DSR - 5.20. connections etc. as required.
Metre 250.00 1,599.00 399,750

12.00 Supplying and fixing earth bus of 50mmx6mm GI strip on surface for
Non DSR connections etc as required.
Metre 800.00 350.00 280,000
a 60 mm x 10 ( or 50 x 12) mm x 1.2 mtrs length copper earth bus bar with
MR insulators, making suitable size holes etc as required
Sets 150.00 2,500.00 375,000
b 60 mm x 10 ( or 50 x 12) mm x 1.2 mtrs length GI earth bus bar with insulators,
MR making suitable size holes etc as required
Sets 150.00 2,500.00 375,000
c Providing and fixing OF 50 mm x 10 mm thick copper tape.
MR
RM 150.00 1,950.00 292,500
d Providing and fixing 8 SWG GI wire.
MR
RM 1,500.00 18.00 27,000

13.00 Providing and laying GI tape 32 mm X 6 mm from earth electrode directly in


DR DSR ground as required.
Metre 100.00 185.00 18,500

TOTAL FOR SH-3 - EARTHING SYSTEM


2,997,154

351
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-04 LIGHTNING PROTECTION SYSTEM

1.00 Lightning Arrestor:Supply, installation, testing and commissioning of External


Lightning wide area protection system based on Eaarly Streamer Emission
(ESE) technology. Device shall emit electromagnetic impulse in the form of a
streamer into the air microseconds earlier than naturally formed streamers.
Non DSR Device confirmg to NFC 17-102 and UNE 21186 Standards. Appropriate non
penetrating mounting arrangement. The device shall be mounted at
suitable clear to the highest point on the roof top. (Model selected shall give
coverage of 79 M radius @ min 5M height from terrace )
Each 2.00 154,800.00 309,600

2.00 Down conductor:Supply, installation, testing and commissioning of 70 Sqmm


Non DSR twisted 19-Strand, bare Cu cable on surface/wall / as per site requirement
and complete in all respect.
Metre 200.00 700.00 140,000

3.00 Lightning Counter :Supply and installation of counting the number of


Non DSR lightning strikes without any power supply.
Each 2.00 22,500.00 45,000

4.00 Maintenance Free Earthing:Supply, installation, testing and commissioning of


maintenance free electrolytic earthing system with 10 feet's rod, 2 inches dia,
2mm thick that does not require manual addition of water. The system should
be stable operation for at least 30 years. The electrode shall be electrolytic
grade copper rod pre-filled with hygroscopic powder and provided with
Non DSR suitable breathing and leaching ports at the ends. The electrode shall be
surrounded by suitable powdered form of backfill so as to provide maximum
contact between the electrode and the backfill. The earthing pit shall be
provided with suitable sturdy test well for observation. (The installation
procedures should be followed as instructed by the Earth Electrode Supplier).
Set 6.00 12,500.00 75,000

5.00 Test Link :Supply and installation of test link in weather proof IP 65 BOX.
Non DSR
Each 6.00 2,500.00 15,000

352
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.00 Supply, installation, testing and commisioning of 2 x 25W LED Aviation
abstruction light medium bay type 62, complete with lamp, lamp holder,
Condenser necessary connecting wire, 1 X 25 AV with all necessary
Non DSR
hardware, accessories as required for complete installation. Rate shall
include the cost of necessary steel structures , fixing arrangements in this item.
Refer drawing. Each 2.00 13,908.00 27,816

7.00 Providing and fixing M.S.. tape 20 mm X 3 mm thick on parapet or surface of


Non DSR wall for lightning conductor complete as required .
metre 1,500.00 52.00 78,000

TOTAL FOR SH-04 - LIGHTNING PROTECTION SYSTEM 690,416


LIGHT FIXTURES AND FANS:
SH-05

1.00 S/F Modular Type Electronic Fan Regulator : Supplying and fixing stepped
type electronic fan regulator on the existing modular plate & switch box
DSR - 1.25
including connections but excluding modular plate etc. as required.
Nos 200.00 284.00 56,800

2.00 ITC fluoresent fitting directly on surface : Installation ,testing and


commissioning of pre-wired .fluorescent fitting /compact fluorescent fitting of
DSR - 1.41
all types ,complete with all accessories and tube etc.directly on ceiling/wall
,including connection with 1.5 sq.mm FRLS PVC insulated ,copper conductor
,single core cable and earthing etc.as required.
Nos 1,000.00 91.00 91,000

3.00 ITC fluoresent fitting on false ceiling : Installation ,testing and commissioning
of pre-wired .fluorescent fitting /compact fluorescent fitting of all types
DRDSR - ,complete with all accessories and tube etc.directly on ceiling/wall ,including
1.41
connection with 1.5 sq.mm FR PVC insulated ,copper conductor ,single core
cable and earthing etc.as required. Nos 3,510.00 149.00 522,990

4.00 ITC Ceiling Fan : Installation ,testing and commissioning of ceiling fan
including wiring the down rods of standard length (upto 30 cm) with 1.5
DSR - 1.44
sq.mm FR PVC insulated ,copper conductor ,single core cable etc.as
required. Nos 150.00 95.00 14,250

353
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

5.00 Installation, testing and commissioning of ceiling fan, including wiring the
down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated,
DSR - 1.45 copper conductor, single core cable, including providing and fixing
phenolic laminated sheet cover on the fan box etc. as required.
Nos 50.00 122.00 6,100

6.00 Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia,
heavy gauge including painting etc. as required. (Note : More than 5 cm
DSR - 1.47
length shall be rounded to the nearest 10 cm and 5 cm or less shall be
ignored) Nos 10.00 23.00 230

7.00 Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm
dia, heavy gauge including painting etc. as required. (Note : More than 5
DSR - 1.48
cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be
ignored) Nos 40.00 27.00 1,080

8.00 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.


DSR-1.49
Nos 200.00 26.00 5,200

9.00 Installation of exhaust fan in the existing opening, including making good the
DSR -1.50 damage, connection, testing, commissioning etc. as required.

a DSR - Upto 450 mm sweep


1.50.1 Nos 30.00 204.00 6,120

10.00 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of
DSR -1.51 all sizes.
Nos 200.00 90.00 18,000

11.00 Supply of Wall Bracket Light aesthetic wall/ceiling mounted luminaire


suitable for 1 x TCH 14W , with low loss electronic ballast, 14W TCH lamp
NON DSR complete with all accessories etc as required. Philips make (Vector 14W TCH
207) or Bajaj Make - BTIP 114 ACR.
Nos 100.00 461.00 46,100

12.00 Supply of 1 x 18 W indoor decorative surface mounted/hanging LED light


NON DSR fixtures suitable for 1 no. of 18W LED lamps prewired complete with all
accessories required as per Insta Power D-Lite LX/18 W.
Nos 1,200.00 2,800.00 3,360,000

354
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
17.00 Supply of 1 x 28 W indoor decorative surface mounted/hanging LED light
NON DSR fixtures suitable for 1 no. of 28 W LED lamps prewired complete with all
accessories required as per Insta Power Lite Master 4`.
Nos 250.00 2,300.00 575,000

18.00 Supply of 2 x 28 W indoor decorative surface mounted/hanging LED light


NON DSR fixtures suitable for 2 nos. of 28 W LED lamps prewired complete with all
accessories required as per Insta Power Lite Master 4`. Nos 525.00 4,000.00 2,100,000

19.00 Supply of Bulk Head Light fixture with lamp complete with all accessories etc
NON DSR as required. Insta Power Bulkhead Nos 50.00 1,800.00 90,000

20.00 Supply of 36 W indoor decorative surface mounted/False Ceiling Mounted


NON DSR LED light fixtures suitable for 1 no of 36 W LED lamp prewired complete with
all accessories required as per Insta Power Moon Light.
Nos 1,250.00 5,000.00 6,250,000

21.00 Supply of 20 W indoor downlighter Ceiling Mounted LED light fixtures


NON DSR prewired complete with all accessories required as per Insta Power D-Lite
LX/30 W. Nos 1,300.00 3,500.00 4,550,000

22.00 Supply of 30 W indoor square decorative surface mounted/False Ceiling


Mounted LED light fixtures suitable for 1 no of 30 W LED lamp prewired
NON DSR
complete with all accessories required as per Insta Power Square Light -
Omega. Nos 500.00 5,000.00 2,500,000

23.00 Supply of 30 W indoor square decorative surface mounted/False Ceiling


Mounted LED light fixtures suitable for 1 no of 30 W LED lamp prewired
NON DSR
complete with all accessories required as per Insta Power Square Light -
Prisma. Nos 250.00 5,000.00 1,250,000

24.00 Supply of Mirror Light aesthetic wall/ceiling mounted luminaire suitable for 1
x TCH 14W , with low loss electronic ballast, 14W TCH lamp complete with all
NON DSR accessories etc as required. Philips make (Vector 14W TCH 207) or Bajaj
Make - BTIP 114 ACR.
Nos 50.00 461.00 23,050

355
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
25.00 Supply of inbuilt battery backup emergency light complete with all
accessories etc as required. Legrand Make CAT No. 572222 White or Bajaj
NON DSR
Make - BTIR 128 with Battery Backup, Prolite Make Emergency Light..
Nos 75.00 2,500.00 187,500

26.00 Supply & Fixing of Ceiling mounted (surface/flush) high performance,


Movement Detector with the coverage of 6Mtrs dia complete with
NON DSR
necessary Sensor control wiring. Hager make EE804 /EE 805 or Equivalent
Nos 100.00 3,907.00 390,700

27.00 Supply, installation, testing and commissioning of Surface mounted, Dual


lens, high performance, Presence detector with the coverage of 4 Metre
NON DSR along lens & 3.5 metre with vertical to lens with necessary Sensor control
wiring. Hager make EE815 or equivalent
Nos 294.00 6,000.00 1,764,000

32.00 Supply, installation, testing and commissioning of Surface mounted, Dual


lens, high performance, Movement Detector with the coverage of 16 Metre
along lens & 10 metre with Lateral to lens,Circular Coverage Dia 6 Metre with
NON DSR
necessary Sensor control wiring. Hager make EE870 or Equivalent(For Double
Height Area).
Nos 278.00 6,000.00 1,668,000

33.00 Supplying and fixing of 400W high performance flood light luminiare suitable
for use with HPSV lamp SON-T 400W luminaire complete with glass cover,
NON DSR control gear, capacitor 400W HPSV lamp etc. the rate shall include
necessary fixing arrangements make WIPRO WFZ42400 / GE Zion 400W / Bajaj
BJFL 400 SV Nos 6.00 8,377.00 50,262

34.00 Supply and fixing of 150 W high performance flood light luminaire suitable for
use with HPSV lamp SON-T 150W luminaire complete with , Glass cover,
NON DSR control gear, capacitor, 150W HPSV lamp, etc. The rate shall include the cost
of necessary fixing arrangements Make: Philips MPF900 1x SON -TP 150 W IC A
WH.
Nos 10.00 5,500.00 55,000

35.00 Supply and fixing of 250 W high performance flood light luminaire suitable for
use with HPSV lamp SON-T 250W luminaire complete with , Glass cover,
NON DSR control gear, capacitor, 250W HPSV lamp, etc.. The rate shall include the cost
of necessary fixing arrangements Make: Wipro WFZ 42250 / GE Zion 250W /
Bajaj BJFL 250 SV Nos 22.00 5,528.00 121,616

356
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

36.00 Supply and fixing of 1000 W high performance flood light (Fascade Lighting
)luminaire suitable for use with HPSV lamp SON-1000W luminaire complete
NON DSR with , Glass cover, control gear, capacitor, 1000W HPSV lamp, etc. The rate
shall include the cost of necessary fixing arrangements Make: Philips RVP 501
M 1x SON-1000W E-40. or equivalent. Nos 12.00 30,000.00 360,000

37.00 Supply and fixing of 150 W high performance flood light luminaire suitable for
use with HPSV lamp SON-T 150W luminaire complete with , Glass cover,
NON DSR control gear, capacitor, 150W HPSV lamp, etc. The rate shall include the cost
of necessary fixing arrangements Make: Philips MPF900 1x SON -TP 150 W IC A
WH. Nos 25.00 6,000.00 150,000

38.00 Supply and fixing of LED Strip light .(Insta Power Magic Glow or Equivalent)
NON DSR
Nos 610.00 3,500.00 2,135,000

39.00 NON DSR Supply and fixing of Fibre Optics light Mtr 1,100.00 2,200.00 2,420,000

40.00 Ceiling Fan : Supplying of capacitor type1200 mm sweep ceiling fan


complete with blades, shakle etc. with high breeze, high speed for operation
NON DSR on 230V, 50 Cy. Single phase A.C. supply confirming to IS 374-1979 and with
double ball bearing system The fan shall be green rated as per BEE norms.
Nos 150.00 1,593.00 238,950

41.00 Ceiling Fan : Supplying of capacitor type900 mm sweep ceiling fan complete
with blades, shakle etc. with high breeze, high speed for operation on 230V,
NON DSR 50 Cy. Single phase A.C. supply confirming to IS 374-1979 and with double
ball bearing system The fan shall be green rated as per BEE norms.
Nos 50.00 1,593.00 79,650

42.00 Supply, of Exhaust fan 150mm light duty 230 V AC 50 Hz 1400 RPM with
condenser complete erected in position with n/c materials Fan motor with
NON DSR
moisture treatment and class E insulation & With bird protective screen
Nos 10.00 1,346.00 13,460

43.00 Supply and fixing of metal fan hook box of 10 mm M.S. round bar , bounded
to to RCC bar up to 50 mm length each side & pierced through a 16 SWG
NON DSR thick MS bowl 100 mm dia , depth up to 75 mm , complete erected in
position . With one coat of red oxide paint and 2 coats of synthetic paint .
Nos 200.00 301.00 60,200

357
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

44.00 NON DSR Exhaust fan of 450mm dia. 900rpm single phase heavy duty.
Nos 10.00 4,000.00 40,000

45.00 NON DSR Exhaust fan of 380mm dia. 900rpm single phase heavy duty.
Nos 10.00 3,000.00 30,000

46.00 Supply, installation, testing and commissioning of Pop Up Power Points in


Non DSR Floor complete with all accessories as required.
Nos. 50.00 3,000.00 150,000

47.00 Non DSR Auditorium

47.1 DIN Rail Adaptive Power Modules has 4 Phase Adaptive outputs, 800 W (Zone
1), 500 W (Zones 2, 3 and 4) that Automatically selects leading edge or
trailing edge dimming for incandescent/halogen, electronic /magnetic low
voltage and neon/cold cathode light sources. It can also control direct
dimmable CFL/LED loads. RTISSR technology ensures that each output dims
smoothly and is flicker-free.
Nos. 2.00 53,640.00 107,280

47.2 DIN Rail 4 zone 0-10 volt dimming module, with 4 corresponding feed through
10 ampere switched outputs. Each 0-10 volt output can source or sink 50ma
per output. It also provides one Contact Closure Input. Requires mains/line
voltage feed.
Nos. 2.00 43,560.00 87,120

47.3 Lutron 8 scene IR keypad and with master raise/lower and off capabilities
Nos. 2.00 26,040.00 52,080

47.4 Lutron 8 Scene Hand Held Remote


Nos. 2.00 16,320.00 32,640

47.5 Local Enclosure


Nos. 1.00 10,000.00 10,000

47.6 Lutron Occupancy sensor - Ceiling mount, dual technology (infrared &
Ultrasonic), 500 sq ft, active high, 20-24VDC, 180 degree field of view, white
with relay. The self-adapting internal microprocessor should analyze the
composite sum of both signals to eliminate time-consuming adjustments.
Nos. 2.00 12,600.00 25,200

358
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
47.7 Crestron Three Series central processor presents a giant leap forward in
control system design. Featuring the all new Core 3™ control engine, the
three series control system forms the core of the modern networked home,
unleashing more power than ever for integrating home entertainment, AV
distribution, security and environmental systems. And, with built-in infiNET EX®
wireless technology, on-screen display, native mobile and Web-based
control, and onboard media rendering, the control system affords vast new,
more affordable ways to control everything in the home through a
streamlined hardware approach.In Crestron Three Series System provides
Eight IR port with Three RS-232 port and eight relay port.
Nos. 1.00 157,200.00 157,200

47.8 IR Probe: It is an IR (infrared) emitter probe designed to adhere directly over


the IR sensor window of a television, DVD player, or any other IR controllable
device. Nos. 5.00 1,800.00 9,000

47.9 Crestron IR Splitter used to control five different devices from a single IR port
of Crestron processor. Nos. 1.00 9,600.00 9,600
Total SH 05- LIGHT FIXTURES AND FANS
31,870,378

SH-06 TELEPHONE SYSTEM

1.00 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
DSR - 1.53
recessed steel/ PVC conduit as required. Metre 15,760.00 33.00 520,080

2.00 Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.

a DSR - 25mm
1.21.2 Metre 8,830.00 65.00 573,950

b DSR - 32mm
1.21.3 Metre 3,782.40 32.00 121,037

359
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

3.00 Supplying and fixing modular switch/ socket outlet,on the existing modular
DSR - 1.24 plate & switch box including connections but excluding modular plate etc.
as required.
a DSR - Telephone Outlet (RJ-45)
1.24.6 Nos. 394.00 95.00 37,430

4.00 Laying of PVC insulated armoured 400 Pair with 0.5 mm dia, Tinned copper
Derived
conductor Telephone cables in exisitng laid Concealed/Surface conduits,
DSR REF:
7.5.2 cables trays.
Metre 600.00 18.50 11,100

5.00 Supply and installation of wall/recessed mounting KRONE connector type


telephone tag block of following sizes in sheet metal enclosure of suitable
Non DSR
dimensions fabricated out of 16 SWG sheet steel with castle key lock,
hinged gasketed type cover including termination of telephone cables,
making connections, painting of box etc, complete as required.

a 10 Pair Tel Tag Block


Nos. 12.00 273.00 3,276

b 50 Pair Tel Tag Block


Nos. 12.00 1,800.00 21,600

c 400 Pair Tel Tag Block


Nos. 2.00 2,500.00 5,000

6.00 Supply of following size anealed tinned copper conductor PVC insulated
and sheathed armoured copper telephone cables with suitable clamps,
Non DSR saddles on existing cable trays / raceways etc and including making terminal
joints complete as required.

a 10 Pair
Metre 3,600.00 83.00 298,800

b 50 Pair
Metre 1,200.00 415.00 498,000

c 400 Pair
Metre 600.00 3,260.00 1,956,000

360
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
7.00 Supply , Erecting & Commissioning of Main Distribution Frame (MDF) box
indoor type with wall mounting facility having front door with lock and
Non DSR suitable for following capacity along with aluminium frame for mounting
krone modules. Complete cabinet fabricated from 18SWG CRCA Sheet with
powder coated in approved manner

a 400x400 pairs
set 1.00 36,350.00 36,350

Total SH 06- TELEPHONE SYSTEM


4,082,623

FIRE ALARM SYSTEM


SH-07

1.00 Wiring in existing conduit : Supplying and drawing following sizes of FR PVC
DSR - 1.17 insulated copper conductor , single core cable in the existing
surface/recessed Steel /PVC conduit as required.

a 2 x 1.5 sq.mm
DSR -
1.17.2 Metre 25,000.00 36.00 900,000
b DSR - 3 x 1.5 sq.mm
1.17.3 Metre 500.00 50.00 25,000

2.00 S/F Steel conduit : Supplying and fixing of following sizes of Steel conduits
along with accessories in surface/ recess including painting in case of
DSR – 1.20 surface conduit,or cutting the wall and making good the same in case of
recessed conduit as required.
a DSR – 20mm
1.20.1 Metre 500.00 121.00 60,500
b DSR – 25mm
1.20.2 Metre 20,000.00 142.00 2,840,000

c DSR – 32 mm
1.20.3 Metre 300.00 193.00 57,900

361
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.00 Layingof 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng hume pipes.
Derived
DSR – 7.5.1
Metre 200.00 15.00 3,000

4.00 Laying of of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables on surface


Derived
including supply and fixing of G.I. Spacer, saddles etc.
DSR – 7.7.1
Metre 300.00 25.00 7,500

5.00 DerivedDS Laying of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng laid
R – 7.8.1 Concealed/Surface conduits, cables trays. Metre 25.00
25,000.00 625,000

6.00 Supply, Installation, Testing & Commissioning of Analog Addressable type Self
Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting
NON -DSR
base, LED, Address Switch, complete with MS Powder coated Junction Box for
mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends,
cable compression glands, cable tags and Ferruling. (BFC)
Nos 455.00 5,200.00 2,366,000

7.00 Supply, Installation, Testing & Commissioning of Analog Addressable type Self
Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting
NON -DSR
base, LED, Address Switch, complete with MS Powder coated Junction Box for
mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends,
cable compression glands, cable tags and Ferruling. (AFC)
Nos 430.00 5,200.00 2,236,000

8.00 Supply, Installation, Testing & Commissioning of Analog addressable Rate of


Rise Cum Fixed temperature detector with standard mounting base, LED,
Address Switch, complete with MS Powder coated Junction Box for mouting
on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling. Nos 268.00 4,400.00 1,179,200

9.00 Supply, Installation, Testing & Commissioning of Analog addressable Duct


Mounted Photoelectric Smoke detector with duct housing, sampling tube,
mounting base, Address Switch and all other accessories, complete with
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 88.00 16,400.00 1,443,200

362
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
10.00 Supply, Installation, Testing & Commissioning of Very Early Warning Smoke
Detection System having minimum sensitivity of 0.02% obs/ft. The system shall
be UL Listed and shall meet the NFPA-72 requirements of VEWFD. Cost to
include all accessories (if required) like sampling pipe, input modules, power
supplies etc to complete the system. Nos 4.00 27,500.00 110,000

11.00 Supplying, installation, testing and commissioning of Multi-criteria Fire/CO


Addressable Detector that combines four separate sensing elements in one
unit (smoke,CO,Flame, and heat) with lockable removal base with
connector for loop in and loop out, insect resistant screen and rotary/binary
decimal switch, built - in tamper resistant features including connections etc.
as per specifications complete as required.
Nos 3.00 22,800.00 68,400

12.00 Supply, Installation, Testing & Commissioning of Response Indicator with


matching screws complete with GI Junction box, Cable lugs at cable end
and ferruling.
Nos 430.00 118.00 50,740

13.00 Devices

13.01 Supply, Installation, Testing & Commissioning of Addressable Dual Action


Manual Pull Station with Adddress Switch and all mounting accessories ,
complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 47.00 6,700.00 314,900

13.02 Supply, Installation, Testing & Commissioning of Fireman's Phone Jackwith all
mounting accessories, complete with MS Powder coated Junction Box for
mounting on Surface, Cable Lugs at Ends and all required accesories for
mounting at site complete as requried.
Nos 47.00 5,000.00 235,000

13.03 Supply, Installation, Testing & Commissioning of Addressable Module for Fire
Phone Jack with Adddress Switch and all mounting accessories, complete
with MS Powder coated Junction Box for mouting on Surface, Cable lugs at
Ends, cable compression glands, cable tags and Ferruling. Nos 47.00 5,800.00 272,600

363
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
13.04 Supply, Installation, Testing & Commissioning of Addressable Relay Module
with Address Switch and all mounting accessories complete as required.
Shall be complete with Pilot Relay for Tripping of Third Party Equipment,
suitable for switching 5A/15A current through the Relay contacts , MS Powder
coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.
Nos 10.00 5,800.00 58,000

13.05 Supply, Installation, Testing & Commissioning of Addressable Control Module


with Address Switch and all mounting accessories, complete with MS Powder
coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.
Nos 94.00 5,800.00 545,200

13.05 Supply, Installation, Testing & Commissioning of Fault Isolator Module ,


complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 150.00 5,100.00 765,000

13.06 Supply, Installation, Testing & Commissioning of Directional Sounders with


20Hz to 20 KHz operating frequency with minimum 8 distinct sound patterns
to indicate Exit doors and direct occupants for safe and fast evacuation ,
complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 47.00 21,000.00 987,000

13.07 Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Voice
Evacuation Speaker having power taps upto 2W and frequency response of
400 to 4000Hz for Voice Evacuation. Nos 259.00 2,300.00 595,700

13.08 Supply, Installation, Testing & Commissioning of Wall Mounted Voice


Evacuation Speaker having power taps upto 2W and frequency response of
400 to 4000Hz for Voice Evacuation. Nos 180.00 5,400.00 972,000

13.09 Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Muli-
Candela Strobe with all required accessories for mounting complete as
required.
Nos 47.00 6,800.00 319,600

14.00 Control And Annunciation

364
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

14.01 Supply, Installation, Testing & Commissioning of Microprocessor based 10


loop capacity , Networkable Analogue Addressable type Fire Alarm Control
panel.

The FACP shall have minimum 640 character Display with fully functional
QWERTY Keypad. Each loop shall have a maximum loading of 125 detectors
and 125 devices in one loop with 20% spare capacity. Four access levels,
flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts
sealed lead acid batteries sufficient for 24 hours normal working and for 2
hours during an emergency conditions as required. The FACP shall be UL 9th
Edition Listed. FACP should be with Network Communication Module with
true peer to peer Connectivity.

Failure of Fire Alarm Panel CPU shall not result in failure of operation of
Amplifiers. Hence if the Digital Audio Amplifiers are CPU Rail Mounted,
consider 1 No. CPU dedicated for Digiital Audio Amplifier Bank.

FACP cost to include all necessary cards, modules, enclosure, CPU and
associated acccessories to complete the system design. All components Nos 2.00 971,500.00 1,943,000
including enclosures shall be UL Listed.

365
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
14.02 Supply, Installation, Testing & Commissioning of Network Control Annunciator
for Fire Command Station with Digital Voice Command Centre with 2 way
Fire Fighters Communication System.

The DVC shall have an Integrated 8 Channel Digital Audio Command Centre
with a capacity to communicate and transmit pre-recorded and paging
messages through the Digital Audio Amplifiers distributed across various floors
of the building on a Digital Audio Loop with zone control function and other
accessories required to complete the system. The System shall have minimum
of 24 Zone Selection Switched.

The Network Control Annunciater and Digital Voice Command Centre shall
be enclosed in the same enclosure and both shall act as independent nodes
on the true peer to peer network.

The Networked Annunciater shall have minimum 640 character backlit LCD
display with QWERTY keypad, control interface and "soft" and "hard" keys.

The NCA shall have control and display capabilities for all nodes on the
network.

NCA shall be capable to select any zone to relay voice evacution message
from the fire command station.

Voice Command Center shall have a true Network Communication Module Nos 1.00 542,690.00 542,690

14.03 Supply, Installation, Testing & Commissioning of Digital Audio Amplifier / Zone
Amplifier capable of processing 1 of 8 audio channels and total of 100W at
70.7 VRMS output along with necessary enclosures. The DAA shall be fully
monitored for fault and alarm reporting. Power Amplifiers shall not be
permitted. UL Listed.

Nos 9.00 304,600.00 2,741,400

14.04 Supply, Installation, Testing & Commissioning of Power Supply Unit - 240VAC
to 24VDC - 6Amps. Power Supply shall be UL Listed with Necessary Battery
Backup.
Nos 1.00 64,700.00 64,700

366
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.00 Software and Gateways

15.01 Supply, Installation, Testing & Commissioning of Fire Command Station


including Graphical User Interface Software. The GUI based main network
software shall be capable of graphically representing each node being
monitored with floor plans and icons depicting the actual locations of the
various systems; and / or sensors’ locations. The GUI software shall be located
in control room and shall monitor all the blocks panel connected with each
other. The software shall provide the facility to Monitor, Control all the Digital
Voice Evacuation as well as 2 way communication from main control room
using voice signals over Fire Network along with the Fire detection signal. The
Graphic workstation shall act as an independent node communicating on
the true peer to peer network (failure of any CPU shall not result in failure of
Graphic Workstation). Nos 2.00 251,300.00 502,600

17.02 Supply, Installation, Testing & Commissioning of BACKNET connectivity to


integrate with Building Management System Nos 1.00 256,800.00 256,800

18.00 Cabling

18.05 Providing, testing and installing / fixing of approved make 20 mm dia.MS


Non DSR flexible conduits on ceiling / wall / floor etc. complete with accessories like,
Junction boxes, Collars, Bends etc.
metre 1,875.00 60.00 112,500

Total SH 07- Fire Detection & Alarm System 23,201,130

SH-08 DATA NETWORKING

SH-08 A ACADEMIC BLOCK

1.00 LAN SYSTEM

1.01 Supplying & laying of PVC sheathed flame retardant Untwisted Pair
(Untwisted Pair (UTP)) Cable of Cat - 6 back bone cable for Data & Voice
outlets. Mtr 60,000.00 53.00 3,180,000

367
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
1.02 Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6
RJ-45 information outlet module for Data & Voice.
Each 1,661.00 550.00 913,550
1.03 Supplying, installing, testing and commissioning of 24 Port Cat - 6 Untwisted
Pair (UTP) Patch Panel for Data Networking for back bone cable.
Each 59.00 17,050.00 1,005,950
1.04 Supplying, installing, testing and commissioning of 24 Port Cat - 6 Untwisted
Pair (UTP) Patch Panel for Data Networking for Voice
Each 34.00 17,050.00 579,700
1.05 Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6
Patch Cord of following length. 7ft
Each 1,661.00 415.00 689,315
1.06 Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6
Patch Cord of following length. 4ft
Each 3,322.00 350.00 1,162,700
1.07 Supply installation testing and commissioning 2- Port Mosaic Faceplate -
White Each 113.00 220.00 24,860
1.08 Supply installation testing and commissioning Blank Insert For Faceplate
Each 473.00 180.00 85,140
1.08 Supply installation testing and commissioning 4- Port Mosaic Faceplate -
White Each 360.00 875.00 315,000
2.00 Server & Wall mount Rack and cable management

2.01 Supply installation testing and commissioning of 600 mm x 600 mm 15 U


230 V AC 90 CFM fan 2 , three Hardware packet 1 set ( containing 20 Nos
each of 3), stationary shelf , Two Cable manager 1U height.
Each 12.00 21,750.00 261,000
2.02 Supply installation testing and commissioning of 600 mm x 1000 mm 42 U
230 V AC 90 CFM fan 2 , three Hardware packet 1 set ( containing 20 Nos
each of 3), stationary shelf , Two Cable manager 1U height. Varitical cable
manager . Each 3.00 99,875.00 299,625
2.03 Supply installation testing and commissioning 1U Horizontal Cable Manager
(For Field Cables & Switches)
Each 36.00 885.00 31,860
2.04 Supply installation testing and commissioning 6 Socket Universal Power Strip
with MCB
Each 10.00 300.00 3,000

368
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.05 Supply installation testing and commissioning Extra Hardware packets for
Racks
Each 21.00 300.00 6,300
2.06 Supply installation testing and commissioning Labels for 4-pair Patch Cords
(70 labels per sheet)
Set 4.00 375.00 1,500
2.07 Supply, installation, testing and commissioning of Category 5 Riser cable
consisting of multiple core or solid copper conductors of 24 AWG size
insulated with expanded polyethylene covered by a PVC skin and inner
shielding for grounding. The core shall be covered by a layer of plastic tape
and overlaid with a corrugated PVC plastic. The cable shall be as per the
specifications laid down in the tender.

2.07.1 25 pair riser cable


Mtr 2,000.00 145.00 290,000
3.00 EDGE SWITCHES

3.01 Supply installation testing and commissioning 48 Port 10/100/1000Mbps + 4


ports for optional SFP/ SX Modules supporting 1G, layer 2 switch with
Stacking cable (Non-blocking switch fabric, IPv6 ready), option for RPS
Each 32.00 88,125.00 2,820,000

4.00 CORE SWITCHES

4.01 Supply installation testing and commissioning Layer 3 Switch with minimum of
03Port 1G Fiber + 24 Port Giga Copper switch, supporting Multimode SFP/ SX
modules. Should have Non-blocking switch fabric, IPv6 Ready, with RPS. The
core switches, should be implemented in Active - Active, redundant
topology for High Availability.
Each 2.00 323,125.00 646,250
4.02 Supply installation testing and commissioning Multi-Mode SFP /SX
transceivers supporting 1G
Each 10.00 21,750.00 217,500
5.00 BACK BONE FIBER CONNECTIVILTY

5.01 Supply, installation, testing and commissioning of 6 Core Laser Speed 150
outdoor SM Fibre Optic Cable in ground/clamped to existing cable tray,
complete as required
Mtr 3,000.00 205.00 615,000

369
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
5.02 Supply, installation, testing and commissioning of Rack Mount24 port Shelf
LIU's, SC Coupler Adapter Plates, SM LC Couplers, SM SC Pigtails and
additional equipment as required for Fibre Optic terminations of the
complete system including the costs of necessary Retainers, Mounting
arrangements, screws and identification labels etc complete as per
specifications and as required. 41,715.00
Each 1.00 41,715
5.03 6 core SM fiber patch patch 3 mtr
Each 8.00 5,290.00 42,320
5.04. Supply, installation, testing and commissioning of Rack Mount 12 port Shelf
LIU's, SC Coupler Adapter Plates, SM LC Couplers, SM SC Pigtails and
additional equipment as required for Fibre Optic terminations of the
complete system including the costs of necessary Retainers, Mounting
arrangements, screws and identification labels etc complete as per
specifications and as required. Each 4.00 25,500.00 102,000

Total SH 08 A- ACADEMIC BLOCK


13,334,285

IPABX SYSTEM
SH-08 B

1.00 Supply, installation, testing and commissioning Advance Hybrid IP Key


Telephone System
Make : Panasonic /NEC /AVAYA .

• 03 PRI
• 08 Digital Ext.
• 240 Analog Ext(CLI)
• 100 IP Extensions
• Expandable up to 1000 port
02 Channel Simplify Voice Mail / Auto Attendant
PC Telephony CA Assistance (All User)
01 Built-In LAN Port
Conference :-
• 3*10 party Conference
• 8*4 Party Conference
• 32 Party meet me conference Nos 1.00 800,000.00 800,000

370
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.00 Remote Maintenance for programming and software updating.

2.01 MDF Required for IPABX 500 Pair


Nos 2.00 10,500.00 21,000
2.02 UPS required for IPABX with 1 hour backup
Nos 1.00 185,000.00 185,000

4.00 Supplying, installation, testing & commissioning of Telephone Instruments.

4.01 Digital Telephones: 60 DSS


Nos 3.00 20,500.00 61,500
4.02 Analog Telephone
Nos 425.00 1,200.00 510,000

Total SH 08 B- IPABX
1,577,500
SERVER
SH-08 C

1.00 HP Proliant DL380e Gen 8 Rack Server: Intel Xeon E5-2407 (2.2Ghz/4
Core/10MB/6.4GT-s QPI/80W, DDR3-1333, HT, Turbo2-3/3/4/4/5/5)Turbo/ 2x HP
Smart Socket Guides for fast processor installation/ HP Ethernet 1GB 4-port
366i Adapter/ HP smart Array P420/ 1GB FBWC Controller/ 8-SFF/HP 12.7mm
SATA DVD ROM JB Ki/ 1x HP 460W CS Gold Ht Plg Pwr Supply Kit/ HP 1U Gen 8
Management Arm Cable/3-3-3 4h 24X7 warranty

HP DL380e Gen8 E5-2407 Kit

HP 16GB 2RX4 PC3L-12800R-11 KIT

HP 900GB 6G SAS 10K 2.5in SC ENT HDD

HP 460W HE Hot Plug AC Power Supply Kit

Microsoft Windows Server 2012 Standard ROK 1


L.S 1.00 750,000.00 750,000

Total SH 08 C- SERVER
750,000

371
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
TV System
SH-09

1.00 Supplying and fixing following modular switch/ socket on the existing
DSR-1.24 modular plate & switch box including connections but excluding modular
plate etc. as required.
a TV antenna socket outlet
DSR-1.24.7
Each 70.00 93.00 6,510

2.00 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
DSR - 1.53 recessed steel/ PVC conduit as required.
Metre 2,450.00 33.00 80,850

3.00 Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.

a DSR - 25mm
1.21.2 Metre 1,960.00 65.00 127,400

b DSR - 32mm
1.21.3 Metre 300.00 32.00 9,600

4.00 Supply Installation Testing & Commissioning of MATV System with all
Equipments such as Dish, Mixer, Racks, amplifiers, Splitters etc., complete with
all accessories as required.

L.S 1.00 2,500,000.00 2,500,000

Total SH 09- TV System


2,724,360

372
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATED COST OF HOSTEL BLOCK

SUBHE AD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR
HOSTEL BLOCK
A.

SH-01 POINT WIRING AND ACCESSORIES: 8,021,228

SH-02 MV PANELS & DISTRIBUTION BOARDS 3,383,799

SH-03 EARTHING SYSTEM 577,636

SH-04 LIGHTNING PROTECTION SYSTEM 332,208

SH-05 LIGHT FIXTURES AND FANS: 7,854,310

SH-06 TELEPHONE SYSTEM 838,280

SH-07 FIRE ALARM SYSTEM 16,876,058

SH-08 DATA NETWORKING 3,558,465

SH-09 TV SYSTEM 311,600


SUB TOTAL (A) 41,753,584

LESS 5% FOR UPRNN WORKING (2,087,679)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 39,665,905

373
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATE COST OF ELECTRICAL WORKS : HOSTEL BLOCK

SH-01 POINT WIRING AND ACCESSORIES:

Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable in surface /
1.00 DSR - 1.3 recessed steel conduit, with modular switch, modular plate, suitable GI box
and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor
single core cable etc as required.

Group A(Hostel, Residential)


a DSR - 1.3.1
Point 2,126.00 677.00 1,439,302
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed steel conduit, 2 way
2.00 DSR - 1.4 modular switch, modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as
required. Point 100.00 1,069.00 106,900
Wiring for circuit/ submain wiring along with earth wire with the following sizes
3.00 DSR -1.7 of FRLS PVC insulated copper conductor, single core cable in surface/
recessed steel conduit as required
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b DSR - 1.7.2
Metre 200.00
480.00 96,000
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c DSR - 1.7.3
Metre 231.00
250.00 57,750
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d DSR - 1.7.4
Metre 250.00 315.00 78,750
Wiring for light/power plug with 2X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
4.00 DSR – 1.12 along with 1 no. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required.(UPS Power)
Metre 450.00 162.00 72,900
-

374
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Wiring for light/power plug with 2X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
5.00 DSR – 1.12 along with 1 no. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required.(RawPower)
Metre 13,908.00 162.00 2,253,096
Wiring for light/power plug with 4X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
6.00 DSR – 1.13 along with 2 nos. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required.(RawPower)
Metre 3,700.00 275.00 1,017,500
Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes
of FRLS PVC insulated, copper conductor,single core cable in
7.00 DSR – 1.14 surface/recessed medium class PVC conduit as required.

-
DSR – 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
a
1.14.1 Metre 8,500.00 106.00 901,000
DSR – 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
b
1.14.2 Metre 500.00 131.00 65,500
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c DSR-1.14.3
Metre 100.00 162.00 16,200
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d DSR-1.14.4
Metre 200.00 221.00 44,200
-
Supplying and drawing following sizes of FRLS PVC insulated copper
8.00 DSR-1.17 conductor, single core cable in the existing surface/ recessed steel/ PVC
conduit as required. -
1 x 1.5 sq. mm
a DSR-1.17.1
Metre 100.00 22.00 2,200
2x 1.5 sq. mm
b DSR-1.17.2
Metre 100.00 36.00 3,600
3x 1.5sq. mm
c DSR-1.17.3
Metre 100.00 50.00 5,000
4x 1.5 sq. mm
d DSR-1.17.4
Metre 100.00 63.00 6,300
DSR- 2 x 2.5 sq. mm
k
1.17.11 Metre 75.00 53.00 3,975
DSR- 2 x 4 sq. mm
t
1.17.20 Metre 75.00 77.00 5,775

375
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
DSR- 2 x 4 sq. mm
u
1.17.21 Metre 25.00 109.00 2,725
-
Supplying and fixing of following sizes of steel conduit along with accessories
in surface/recess including painting in case of surface conduit, or cutting the
9.00 DSR-1.20
wall and making good the same in case of recessed conduit as required.
-
20 mm
a DSR-1.20.1
Metre 50.00 121.00 6,050
25 mm
b DSR-1.20.2
Metre 100.00 142.00 14,200
32 mm
c DSR-1.20.3
Metre 75.00 193.00 14,475
40 mm
d DSR-1.20.4
Metre 50.00 287.00 14,350
50 mm
e DSR-1.20.5
Metre 25.00 387.00 9,675
-
-
Supplying and fixing of following sizes of medium class PVC conduit along
with accessories in surface/recess including cutting the wall and making
10.00 DSR-1.21 good the same in case of recessed conduit as required.
-
20 mm
a DSR-1.21.1
Metre 100.00 53.00 5,300
25 mm
b DSR-1.21.2
Metre 200.00 65.00 13,000
32 mm
c DSR-1.21.3
Metre 100.00 85.00 8,500
40 mm
d DSR-1.21.4
Metre 100.00 110.00 11,000
50 mm
e DSR-1.21.5
Metre 50.00 144.00 7,200
-

376
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing metal box of following sizes (nominal size) on surface or
in recess with suitable size of phenolic laminated sheet cover in front
11.00 DSR-1.22 including painting etc as required.

-
75 mm X 75 mm X 60 mm deep
a DSR-1.22.1
Each 100.00 89.00 8,900
150 mm X 75 mm X 60 mm deep
c DSR-1.22.3
Each 25.00 111.00 2,775
150 mm X150 mm X 60 mm deep
d DSR-1.22.4
Each 100.00 160.00 16,000
Supplying and fixing following modular switch/ socket on the existing
12.00 DSR-1.24 modular plate & switch box including connections but excluding modular
plate etc. as required. -
-
5/6 amps switch
a DSR-1.24.1
Each 1,000.00 81.00 81,000
2 way 5/6 amps switch
b DSR-1.24.2
Each 25.00 96.00 2,400
15/16 amp switch
c DSR-1.24.3
Each 466.00 111.00 51,726
3 pin 5/6 amp socket outlet
d DSR-1.24.4
Each 1,244.00 79.00 98,276
6 pin 15/16 amp socket outlet
e DSR-1.24.5
Each 466.00 150.00 69,900
Telephone socket outlet
f DSR-1.24.6
Each 194.00 95.00 18,430
TV antenna socket outlet
g DSR-1.24.7
Each 226.00 94.00 21,244
Bell push
h DSR-1.24.8
Each - 111.00 -
-

377
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
S/F Modular Type Blanking Plate : Supplying and fixing modular blanking
plate ,on the existing modular plate & switch box excluding modular plate
13.00 DSR - 1.26
etc. as required.
Each 50.00 23.00 1,150
-
S/F GI Box along with modular plate: Supplying and fixing following size
14.00 DSR – 1.27 /modules, GI box along with modular base & cover plate for modular
switches in recess etc as required. -
DSR – 1 or 2 Module(75mmx75mm)
a
1.27.1 Each 1,911.00 166.00 317,226
3 Module (100mmX75mm)
b DSR-1.27.2
Each 1,710.00 175.00 299,250
4 Module (125mmX75mm)
c DSR-1.27.3
Each 25.00 195.00 4,875
Supply & fixing following modular base and cover plate for modular
15.00 DSR - 1.28 switches in recess etc as required.
-
DSR - 1 or 2 Module
a
1.28.1 Each 1,911.00 79.00 150,969
3 Module
DSR -
b
1.28.2 Each 88.00
1,710.00 150,480
DSR -
4 Module
c
1.28.3 Each 97.00
25.00 2,425
Supplying and fixing 3 pin, 5 amp ceiling rose ,on the existing junction box
17.00 DSR - 1.33 including connection etc. as required.
Each 500.00 43.00 21,500
Supplying and fixing brass batten/angle holder including connection etc. as
18.00 DSR - 1.34 required.
Each 75.00 74.00 5,550
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
19.00 DSR - 1.36 including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.
Each 150.00 163.00 24,450

378
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing stiff pendent with 600 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
20.00 DSR - 1.37 including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.
Each 75.00 163.00 12,225
Providing and fixing 16/0.20mm (0.50sqmm) twin flat flexible,FRLS PVC
insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or
21.00 DSR - 1.39
side of the table/ door etc. as required.
Each 75.00 21.00 1,575
Providing and fixing 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC
insulated, PVC sheathed copper cable direct on the wall with PVC clips etc.
22.00 DSR - 1.40 .
as required.
Each 75.00 19.00 1,425
Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug
DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5
23.00 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
minus1.20.
insulated, copper conductor single core cable for loop earthing as
1)
required.(UPS Power) Metre 50.00 107.00 5,350
Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug
DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
24.00
minus1.20. insulated, copper conductor single core cable for loop earthing as
1) required.(RawPower)
Metre 200.00 107.00 21,400
Wiring for the following light points with 1.5 sq.mm PVC insulated
copper conductor 1100 volts grade stranded flexible FRLS wires of
approved make in concealed or surface mounted 25 mm dia medium
25.00 DRDSR class PVC conduit controlled by SPMCB provided in the DB and earthing of
fixtures with 1.5 sq.mm PVC insulated copper conductor stranded flexible
FRLS wire.(Cost of MCB not to be included here)
-
a One point controlled by one MCB. Points 228.00
30.00 6,840
b Two points controlled by one MCB. Points 456.00
10.00 4,560
c Three points controlled by one MCB. Points 684.00
25.00 17,100
d Four points controlled by one MCB. Points 912.00
15.00 13,680
e Five points controlled by one MCB Points 1,140.00
74.00 84,360
f Six points controlled by one MCB. Points 1,368.00
38.00 51,984

379
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
g Seven points controlled by one MCB. Points 1,596.00
10.00 15,960
h Eight points controlled by one MCB. Points 1,824.00
10.00 18,240
I Nine points controlled by one MCB. Points 2,052.00
45.00 92,340
j Ten points controlled by one MCB. Points 2,280.00
8.00 18,240
-
Supplying and fixing 250x150x75 mm deep, 1.6 mm thick G I Junction box
26.00 NON DSR with coverplate complete as per site requirement. Nos 50.00 500.00 25,000
-
TOTAL FOR SH-01 - POINT WIRING AND ACCESSORIES: - 8,021,228

SH-02 MV PANELS & DISTRIBUTION BOARDS

Providing and fixing following rating and breaking capacity MCCB in existing
cubicle panel board including drilling holes in cubicle panel, making
1.00 DSR - 2.2
connections, etc. as required.

100 Amp, 16 KA, TP MCCB


a DSR - 2.2.1
Each 1.00 3,205.00 3,205
200 Amp, 25 KA , TP MCCB
b DSR - 2.2.5
Each 1.00 8,814.00 8,814
400 Amp, 35 KA , TP MCCB
c DSR - 2.2.9
Each 1.00 17,372.00 17,372
-
2.00 DSR - 2.3 S/F prewired SP MCB DB : Supplying and fixing following way single pole and
neutral,sheet steel MCB distribution board 240 volt,s on surface/recess,
complete with tinned copper bus bar , neutral bus bar, earth bar, din bar,
interconnections , power painted including earthing etc. as required. (But
without MCB/RCCB/Isolator ).
-
-
a DSR - 2.3.5 2+4 way /6 Way ,Double Door Each 923.00
2.00 1,846
b DSR - 2.3.6 2+6 Way / 8 Way,Double Door Each 1,041.00
2.00 2,082
c DSR - 2.3.7 2+8 Way / 10 way,Double Door Each 1,132.00
2.00 2,264
-

380
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
S/F prewired TP MCB DB : Supplying and fixing following way prewired TP&N
MCB distribution board of steel sheet for 415 volts on surface/recess,
complete with loose wire box, terminal connectors for all incoming and
outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper
3.00 DSR - 2.8
conductor up to terminal blocks , tinned copper bus bar, neutral link, earth
bar , din bar , detachable gland plate, interconnections, power painted
including earthing etc. as required. (But without MCB/RCCB/Isolator ).
-
4 way (4 + 12 ),Double Door
a DSR – 2.8.5
Each 2.00 7,357.00 14,714
6 way (4 + 18 ),Double Door
b DSR – 2.8.6
Each 20.00 9,496.00 189,920
8 way (4 + 24 ),Double Door
c DSR – 2.8.7
Each 20.00 10,405.00 208,100
12 way (4 + 36 ), Double Door (LPDB)
d DSR – 2.8.8
Each 35.00 12,782.00 447,370
S/F vertical type prewired Vertical Type MCB DB : Supplying and fixing
following way prewired Vertical Type TP&N MCB distribution board of steel
sheet for 415 volts on surface/recess, complete with loose wire box of sheet
steel, dust protected, duly powder painted, inclusive of 200 amps tinned
copper bus bar, common neutral link, earth bar , din bar for mounted MCB's,
4.00 DSR - 2.9 terminal connectors for all incoming and outgoing circuits, duly prewired
with adequate size of FRLS PVC insulated copper conductor upto the
terminal connector/neutral link, earthing etc. as required .(But without
MCB/RCCB/Isolator ). (Note: Prewired vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
-
4 Way Double Door
a DSR - 2.9.5
Each 5.00 7,901.00 39,505
8 way Double door
b DSR - 2.9.7
Each 2.00 11,123.00 22,246
S/F 'C' Curve , SP MCB : Supplying and fixing 5 amps to 32 amps, rating,
240/415 volts, 'C' Curve , miniature circuit breaker suitable for inductive load
5.00 DSR - 2.10 of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.
-

381
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
DSR - Single Pole
a
2.10.1 Each 1,950.00 169.00 329,550
DSR - Single Pole and Neutral
b
2.10.2 Each 196.00 441.00 86,436
DSR - Triple pole
c
2.10.4 Each 696.00 -
DSR - Triple pole and neutral
d
2.10.5 Each 887.00 -
-
S/F SP MCB blanking plate : Supplying and fixing single pole blanking plate in
6.00 DSR - 2.11 the existing MCB DB complete etc.as required.
Each 50.00 7.00 350
-
S/F DP MCB isolator : Supplying and fixing following rating, double pole , 240
7.00 DSR - 2.12 volts, isolator in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
-
-
DSR - 40 amps
a
2.12.1 Each 6.00 218.00 1,308
-
S/F FP MCB isolator : Supplying and fixing of following rating, four pole , 415
8.00 DSR - 2.13 volts, isolator in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
-
DSR - 40 amps
a
2.13.1 Each 63.00 659.00 41,517
DSR - 63 amps
b
2.13.2 Each 57.00 670.00 38,190
-
-
S/F SPN RCCB :Supplying and fixing following rating, double pole, (single
phase and neutral), 240 volts, residual current circuit breaker (RCCB), having
9.00 DSR - 2.14 a sensitivity current upto 300 milliamperes in the existing MCB DB complete
with connections, testing and commissioning etc. as required.
-
-

382
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
DSR - 25 amps
a
2.14.1 Each 66.00 1,645.00 108,570
DSR - 40 amps
b
2.14.2 Each 171.00 1,714.00 293,094
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recess along with
16/25/32amps 240 volts "C" curve DP MCB complete with connections, testing
10.00 DSR - 2.16
and commissioning etc. as required.
Each 5.00 617.00 3,085
-
Supplying and fixing TP sheet steel enclosure on surface/ recess along with
16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing
11.00 DSR - 2.17
and commissioning etc. as required.
Each 5.00 868.00 4,340
-
S/F 20 A SPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 240
Volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed
plug top along with 20 Amps, C-Curve, SP MCB, in sheet steel enclosure, on
12.00 DSR - 2.18
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 10.00 954.00 9,540
-
S/F 20 A TPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 20 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
13.00 DSR - 2.19
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 5.00 1,967.00 9,835
-
S/F 30 A TPN MCB industrial socket outlet : Supplying and fixing 30 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 30 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
14.00 DSR - 2.20
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 2.00 2,473.00 4,946
-

383
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
15.00 Supplying,Installation, testing and commissioning of cubical type LT panel
suitable for 415V, 3 Phase,4 wire 50 Hz AC supply system fabricated in
compartmentalized design from CRCA sheet steel of 2mm thick for frame
work and covers, 3mm thick for gland plates i/c cleaning & finishing
completed 9 tank process of powder coating in approved shade,having
extensible type TPN Aluminium alloy bus bars of high conductivity,DMC/SMC
bus bar supports,with short circuit withstand capacity for 1 sec, bottom base
channel of MS section not less that 100 mm x 50mm x 5mm thick, fabrication
shall be done transportable sections,entire panel shall have a common
copper earth bar of size 25mmx5mm at the rear with 2 no's earth stud,solid
connections from main bus bar to switchgears with required size of
alunimium bus bars and control wiring PVC insulated copper conductor S/C
cable alleys,cable gland plates in two half,i/c providing following switch
gears: (with all necessary hardware, accessories as required for complete
installation as per specifications and single line digram).
-
-
Refer CPWD general specification for Electrical works Part IV Sub station
-
Note: 1.Provision for both Bottom & Top cable entry shall be provided in All
Panels .
-
-
All panles shall be indoor type unless otherwise mentioned. Only feeder pillers
shall be outdoor type.
-
-
MV PANELS
-
General Notes:
-
-
A. ACB:
-
-
LSIG (Microprocessor Based) releases shall be used for incoming feeders such
i as Transformers and DG Sets & LSI releases for outgoing breakers. All ACB
shall have Icu = Ics = Icw for 1 Second.
-
-
All 4 Pole ACB shall have fully Rated neutral equal to rating of the breaker &
ii shall be protected against overload & short-circuit .
-
-

384
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Ready-to-close contact shall exist for indicating that all safety parameters
iii are checked & enabling closure of breaker, ensuring at-most safety for the
user -
-
A door interlock shall be provided so that it shall not be possible to open the
iv door until the air circuit breaker moving part is in the disconnected position.
-
-
B. MCCB:
-
-
All MCCBs shall be suitable for 3 Phase 415 Volts AC 50 HZ supply
i. -
-
All MCCBs shall have rated service breaking capacity (Ics) equal to the
ii. ultimate breaking capacity (Icu) at defined operational voltage.
-
-
All MCCBs shall clearly indicate the suitability for isolation in the name plate
iii. identified by the symbol
-
-
All MCCBs shall offer class –II front face i.e. main current path of the circuit
iv. breaker should be isolated from auxiliary section
-
-
All Incomer MCCBs shall be provided with earth fault protection
v. -
-
MCCBs of above250A Microprocessor Based and upto 250A thermal
vi. Magnetic releases.
-
-
This BOQ to be read in conjunction with technical specifications and Single
Line Diagram (attached for reference). If any discrepancy occurs that should
vii. be brought to the notice of Client/Consultant before quoting the price
otherwise stringent condition will be deemed to have been considered.
-
-
All ACBs to be provided with ON/OFF/Trip lamps, 3 NO + 3NC Auxiliary
viii. contacts other than used in control circuit.
-
-

385
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
All Transformer and DG incoming ACBs shall be provided with Microprocessor
ix. based releases & ON/OFF/Trip / Spring charged/ready to close indicating
lamps.
-
-
All MCCBs shall be provided with rotary operating handle and ON/OFF lamps
x. backed by 2Amp control MCB.
-
-
xi. All meters shall be digital type (unless otherwise specified)
-
-
Multi-function meter to be provided as required to cover all the parameters
xii. as mentioned.
-
-
All current/voltage transformer shall be cast resin type.
xiii. -
-
xiv. All indicating lamps shall be LED type.
-
-
Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus
xv. bar is after considering all derating factors. (Bus bar sizing calculation to be
submitted for approval.)
-
-
All internal control wiring shall be heat resistant type.
xvi. -
-
All incoming breakers in Main LT panel shall be electrically interlocked.
xvii. -
-
All TP feeders shall be provided with Isolable neutral link.
xviii.
-
-
Bus bar chamber shall be provided at top only. Incoming and outgoing
xix. cable entry shall be from top/bottom as required.
-
-
Bus couplers in Main MV Panel shall be Microprocessor based with all
xx.
releases. -
-

386
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Bus couplers shall be provided with ON & OFF indicating lights but without
xxi. releases. -
-
All feeders shall be provided with door interlocked with door defeat, pad
xxii. lock facility.
-
-
Live parts shall not be accessible after opening the door, Transparent acrylic
xxiii. sheet to be provided to cover the same.
-
-
Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto
xxiv. terminal block. -
-
xxv. 20% spare control terminal to be provided.
-
-
All MCCBs shall be provided with variable O/L & S/C releases. Incoming
xxvi. MCCB shall be provided with E/F releases also
-
-
All incoming/outgoing cables shall be terminated on links/terminals.
xxvii. -
-
xxviii. All Panels shall have 100 % Neutral Bus Bar Rating. -
-
Degree of protection for following type of distribution panel enclosure shall
xxix. be as per IS: 13947-1993.
-
-
IP 43 for indoor panels.
-
IP 55 for outdoor panels.
-
-
Painting/lettering on Breakers and distribution boards, the location they
xxx. serve, providing on each panel its circuit diagram.
-

387
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
15.01 HOSTEL BLOCK PANELS
-
15.01.1 Non DSR MAIN LT PANEL (HOSTEL BLOCK)
-
Incomer
-
-
630A TP MCCB,25 KA
-
-
Metering & Indication:
-
Each Shall have
-
-
Breaker ON / OFF / TRIP indicating lights with control MCB’s.
-
Set of RYB phase indicating lamps with 2A control MCBs.
-
-
Busbar
-
800A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating). -
Outgoings:
-
-
Set of RYB phase indicating lamps with 2A control MCBs on each outgoing
to be provided.
-
Six (6) Nos. 63 A 4P MCB (10KA)
-
Two (2) Nos. 100 A TP MCCB (25KA)
-
Two (2) Nos. 400 A TP MCCB (25KA)
Set 1.00 200,700.00 200,700
-
MDB (HOSTEL BLOCK)
15.01.2 Non DSR Typical Floor.
-
Incomer
-
-
100A TP MCCB,25 KA
-

388
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
Metering & Indication:
-
Each Shall have
-
-
Breaker ON / OFF / TRIP indicating lights with control MCB’s.
-
Set of RYB phase indicating lamps with 2A control MCBs.
-
-
Busbar
-
160A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).
-

Outgoings: -
-
Set of RYB phase indicating lamps with 2A control MCBs on each outgoing
to be provided. -
-
Four (4) Nos. 63 A 4P MCB (10KA) 53,100.00
Sets 16.00 849,600
-
Meter Board (HOSTEL BLOCK)
15.01.3 Non DSR Stilt & First Floor.
-
Incomer -
-
100A TP MCCB,25 KA -
-
Metering & Indication:
-
Each Shall have
-
-
Breaker ON / OFF / TRIP indicating lights with control MCB’s.
-
Set of RYB phase indicating lamps with 2A control MCBs.
-

389
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
Busbar
-
160A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).
-
Outgoings:
-
-
Set of RYB phase indicating lamps with 2A control MCBs on each outgoing
to be provided.
-
Each Outgoing shall be provided with 3-phase digital type energy meters
with Communication Port.
-
-
Four (4) Nos. 63 A 4P MCB (10KA)
Sets 2.00 121,000.00 242,000
-
15.01.4 Non DSR Lift Panel (HOSTEL BLOCK)
-
Incoming (1 No.):
-
-
100Amp TP+N MCCB, 25kA
-
-
Metering & Indication: -
(0-500) volts digital voltmeter with selector switch protected by 2A control
MCB's -
-
(0-100A) Digital ammeter with Selector Switch and 100/5 amps Cl-1, 5VA CT's
-
-
Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.
-
-
Bus Bars:
-
160A, TPN aluminium , colour coded Sleeved bus bars suitable for 415V, 50Hz.
(after deration)
-

390
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Outgoings
-
Phase indicating lamps with 2A Control MCB shall be provided on each
outgoing.
-
1 Nos. 40A 4P MCB (10 KA)
-
3 Nos. 40A 4P RCBO (30 mA,10 KA)
Set 2.00 85,400.00 170,800
-
S/F 20 A TPN MCB socket outlet : Supplying and fixing 20 Amps, 415 Volts, TPN,
industrial type socket outlet, with 4 pole and earth along with 20 Amps, C-
16.00 Non DSR Curve, TPN MCB, in weather proof enclosure/Floor Junction Box, on surface
or in recess, and complete with connections, testing and commissioning etc.
as required. (Weather Proof Type) Each 5.00 5,500.00 27,500
Supply & Fixing of Four Pole 63 A Manual Change over Switch with Powder
17.00 Non DSR Coated Matalic Encloser as required.
Each 1.00 5,000.00 5,000
-
TOTAL FOR SH-02 - MV PANELS & DISTRIBUTION BOARDS: 3,383,799

SH-03 EARTHING SYSTEM

G.I. earth plate electrode : Earthing with GI earth plate 600mm X 600mm X 6
mm thick including accessories and providing masonary enclosure with
1.00 DSR - 5.4 cover plate having locking arrangement and watering pipe of 2.7 metre
long etc. with charcoal/coke and salt as required.
Set 10.00 4,490.00 44,900
-
Copper earth plate electrode : Earthing with Copper earth plate 600mm X
600mm X 3 mm thick including accessories and providing masonary
2.00 DSR - 5.6 enclosure with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/coke and salt as required.
Set 8.00 9,292.00 74,336
-
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground
as strip earth electrode, including connection/ terminating with G.I. nut, bolt,
3.00 DSR - 5.8 spring, washer etc. as required. (Jointing shall be done by overlapping and
with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Metre 100.00 753.00 75,300
-

391
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and laying 25mm x 5 mm GI strip at 0.50 m below ground as strip
earth electrocde, including connection/terminating with G.I. nut, bolt, spring,
4.00 DSR - 5.9 washer etc. as required. (Jointing shall be done by overlapping and with 2
sets of G.I nut bolt & spring washer sapced at 50mm).
Metre 800.00 109.00 87,200
-
Providing & Fixing 25mm x 5 mm Copper strip in 40 mm dia G.I. Pipe from
5.00 DSR - 5.10 earth electrode including connection with brass nut, bolt, spring, washer
excavation and re-filling etc. as required. Metre 50.00 1,082.00 54,100
-
Providing & Fixing 25mm x 5 mm G.I. Strip in 40 mm dia G.I. pipe from earth
6.00 DSR - 5.11 electrode including connection with G.I. nut, bolt, spring, washer excavation
and re-filling etc. as required. Metre 50.00 421.00 21,050
-
Providing and laying earth connection from earth electrode with 6 SWG dia
G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection
7.00 DSR - 5.12
with G.I. thimble excavation and re-filling as required.
Metre 50.00 151.00 7,550
-
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for
8.00 DSR - 5.20. connections etc. as required.
Metre 50.00 1,599.00 79,950
-
Supplying and fixing earth bus of 50mmx6mm GI strip on surface for
10.00 Non DSR connections etc as required.
Metre 50.00 350.00 17,500
-
Providing and fixing OF 50 mm x 10 mm thick copper tape.
a MR
RM 1,950.00
50.00 97,500
Providing and fixing 8 SWG GI wire.
b MR
RM 18.00
500.00 9,000
-
Providing and laying GI tape 32 mm X 6 mm from earth electrode directly in
11.00 DR DSR ground as required.
Metre 50.00 185.00 9,250
-
TOTAL FOR SH-03 - EARTHING SYSTEM 577,636

392
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-04 LIGHTNING PROTECTION SYSTEM

Lightning Arrestor:Supply, installation, testing and commissioning of External


Lightning wide area protection system based on Eaarly Streamer Emission
(ESE) technology. Device shall emit electromagnetic impulse in the form of a
streamer into the air microseconds earlier than naturally formed streamers.
1.00 Non DSR Device confirmg to NFC 17-102 and UNE 21186 Standards. Appropriate non
penetrating mounting arrangement. The device shall be mounted at
suitable clear to the highest point on the roof top. (Model selected shall give
coverage of 79 M radius @ min 5M height from terrace )
Each 1.00 154,800.00 154,800
-
Down conductor:Supply, installation, testing and commissioning of 70 Sqmm
twisted 19-Strand, bare Cu cable on surface/wall / as per site requirement
2.00 Non DSR
and complete in all respect.
Metre 100.00 700.00 70,000
-
Lightning Counter :Supply and installation of counting the number of
3.00 Non DSR lightning strikes without any power supply.
Each 1.00 22,500.00 22,500
-
Maintenance Free Earthing:Supply, installation, testing and commissioning of
maintenance free electrolytic earthing system with 10 feet's rod, 2 inches dia,
2mm thick that does not require manual addition of water. The system should
be stable operation for at least 30 years. The electrode shall be electrolytic
grade copper rod pre-filled with hygroscopic powder and provided with
4.00 Non DSR
suitable breathing and leaching ports at the ends. The electrode shall be
surrounded by suitable powdered form of backfill so as to provide maximum
contact between the electrode and the backfill. The earthing pit shall be
provided with suitable sturdy test well for observation. (The installation
procedures should be followed as instructed by the Earth Electrode Supplier). Set 3.00 12,500.00 37,500
-
Test Link :Supply and installation of test link in weather proof IP 65 BOX.
5.00 Non DSR
Each 3.00 2,500.00 7,500
-

393
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, installation, testing and commisioning of 2 x 25W LED Aviation
abstruction light medium bay type 62, complete with lamp, lamp holder,
Condenser necessary connecting wire, 1 X 25 AV with all necessary
6.00 Non DSR
hardware, accessories as required for complete installation. Rate shall
include the cost of necessary steel structures , fixing arrangements in this item.
Refer drawing. Each 1.00 13,908.00 13,908
-
Providing and fixing M.S.. tape 20 mm X 3 mm thick on parapet or surface of
7.00 Non DSR
wall for lightning conductor complete as required . metre 500.00 52.00 26,000

TOTAL FOR SH-04 - LIGHTNING PROTECTION SYSTEM 332,208

SH-05 LIGHT FIXTURES AND FANS:

S/F Modular Type Electronic Fan Regulator : Supplying and fixing stepped
type electronic fan regulator on the existing modular plate & switch box
1.00 DSR - 1.25
including connections but excluding modular plate etc. as required.
Nos 509.00 284.00 144,556
-
-
ITC fluoresent fitting directly on surface : Installation ,testing and
commissioning of pre-wired .fluorescent fitting /compact fluorescent fitting of
all types ,complete with all accessories and tube etc.directly on ceiling/wall
2.00 DSR - 1.41
,including connection with 1.5 sq.mm FRLS PVC insulated ,copper conductor
,single core cable and earthing etc.as required.
Nos 2,049.00 91.00 186,459
-
ITC fluoresent fitting on false ceiling : Installation ,testing and commissioning
of pre-wired .fluorescent fitting /compact fluorescent fitting of all types
DRDSR - ,complete with all accessories and tube etc.directly on ceiling/wall ,including
3.00
1.41 connection with 1.5 sq.mm FR PVC insulated ,copper conductor ,single core
cable and earthing etc.as required.
Nos 1,000.00 149.00 149,000
-
ITC Ceiling Fan : Installation ,testing and commissioning of ceiling fan
including wiring the down rods of standard length (upto 30 cm) with 1.5
4.00 DSR - 1.44
sq.mm FR PVC insulated ,copper conductor ,single core cable etc.as
required. Nos 509.00 95.00 48,355
-
5.00 DSR-1.49 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Nos 509.00 26.00 13,234

394
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
Supply of Wall Bracket Light aesthetic wall/ceiling mounted luminaire
suitable for 1 x TCH 14W , with low loss electronic ballast, 14W TCH lamp
complete with all accessories etc as required. Philips make (Vector 14W TCH
6.00 NON DSR
207) or Bajaj Make - BTIP 114 ACR.

Nos 980.00 461.00 451,780


-
Supply of 1 x 18 W indoor decorative surface mounted/hanging LED light
fixtures suitable for 1 no. of 18W LED lamps prewired complete with all
7.00 NON DSR
accessories required as per Insta Power D-Lite LX/18 W.
Nos 1,688.00 2,800.00 4,726,400
-
Supply of 1 x 28 W indoor decorative surface mounted/hanging LED light
8.00 NON DSR fixtures suitable for 1 no. of 28 W LED lamps prewired complete with all
accessories required as per Insta Power Lite Master 4`.
Nos 120.00 2,300.00 276,000
-
Supply of 2 x 28 W indoor decorative surface mounted/hanging LED light
9.00 NON DSR fixtures suitable for 2 nos. of 28 W LED lamps prewired complete with all
accessories required as per Insta Power Lite Master 4`.
Nos 108.00 4,000.00 432,000
-
Supply of Bulk Head Light fixture with lamp complete with all accessories etc
10.00 NON DSR as required. Insta Power Bulkhead
Nos 114.00 1,800.00 205,200
-
Supply of 36 W indoor decorative surface mounted/False Ceiling Mounted
11.00 NON DSR LED light fixtures suitable for 1 no of 36 W LED lamp prewired complete with
all accessories required as per Insta Power Moon Light.
Nos 19.00 5,000.00 95,000
-
Supply of Mirror Light aesthetic wall/ceiling mounted luminaire suitable for 1
x TCH 14W , with low loss electronic ballast, 14W TCH lamp complete with all
12.00 NON DSR
accessories etc as required. Philips make (Vector 14W TCH 207) or Bajaj
Make - BTIP 114 ACR. Nos 50.00 461.00 23,050
-
Supply of inbuilt battery backup emergency light complete with all
accessories etc as required. Legrand Make CAT No. 572222 White or Bajaj
13.00 NON DSR
Make - BTIR 128 with Battery Backup, Prolite Make Emergency Light..
Nos 25.00 2,500.00 62,500
-

395
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Ceiling Fan : Supplying of capacitor type1200 mm sweep ceiling fan
complete with blades, shakle etc. with high breeze, high speed for operation
14.00 NON DSR on 230V, 50 Cy. Single phase A.C. supply confirming to IS 374-1979 and with
double ball bearing system The fan shall be green rated as per BEE norms.
Nos 450.00 1,593.00 716,850
-
Ceiling Fan : Supplying of capacitor type900 mm sweep ceiling fan complete
with blades, shakle etc. with high breeze, high speed for operation on 230V,
15.00 NON DSR 50 Cy. Single phase A.C. supply confirming to IS 374-1979 and with double
ball bearing system The fan shall be green rated as per BEE norms.
Nos 59.00 1,593.00 93,987
Supply, of Exhaust fan 150mm light duty 230 V AC 50 Hz 1400 RPM with
condenser complete erected in position with n/c materials Fan motor with
16.00 NON DSR
moisture treatment and class E insulation & With bird protective screen
Nos 5.00 1,346.00 6,730
Supply and fixing of metal fan hook box of 10 mm M.S. round bar , bounded
to to RCC bar up to 50 mm length each side & pierced through a 16 SWG
17.00 NON DSR thick MS bowl 100 mm dia , depth up to 75 mm , complete erected in
position . With one coat of red oxide paint and 2 coats of synthetic paint .
Nos 509.00 301.00 153,209
18.00 NON DSR Exhaust fan of 450mm dia. 900rpm single phase heavy duty. Nos 4,000.00
10.00 40,000
Exhaust fan of 380mm dia. 900rpm single phase heavy duty.
19.00 NON DSR Nos 10.00 3,000.00 30,000
Total SH 05- Light and Fans
7,854,310

SH-06 TELEPHONE SYSTEM

Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
1.00 DSR - 1.53 recessed steel/ PVC conduit as required.
Metre 6,790.00 33.00 224,070
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
2.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.

DSR - 25mm
a
1.21.2 Metre 3,850.00 65.00 250,250
DSR - 32mm
b
1.21.3 Metre 1,629.60 32.00 52,147

396
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Supplying and fixing modular switch/ socket outlet,on the existing modular
3.00 DSR - 1.24 plate & switch box including connections but excluding modular plate etc.
as required.

DSR - Telephone Outlet (RJ-45)


a
1.24.6 Nos. 194.00 95.00 18,430

Laying of PVC insulated armoured 10 Pair with 0.5 mm dia, Tinned copper
Derived
conductor Telephone cables including excavation,supply & fiiling of sand
4.00 DSR REF:
7.2.1 and bricks .
Metre 1,000.00 133.00 133,000

Laying of PVC insulated armoured 50 Pair with 0.5 mm dia, Tinned copper
Derived
conductor Telephone cables including excavation,supply & fiiling of sand
5.00 DSR REF:
7.2.2 and bricks.
Metre 200.00 141.00 28,200

Derived
Laying of PVC insulated armoured 10 Pair with 0.5 mm dia, Tinned copper
6.00 DSR REF: conductor Telephone cables in exisitng hume pipes.
7.5.1 Metre 200.00 16.00 3,200

Supply and installation of wall/recessed mounting KRONE connector type


telephone tag block of following sizes in sheet metal enclosure of suitable
dimensions fabricated out of 16 SWG sheet steel with castle key lock,
7.00 Non DSR hinged gasketed type cover including termination of telephone cables,
making connections, painting of box etc, complete as required.

10 Pair Tel Tag Block


a
Nos. 16.00 273.00 4,368
100 Pair Tel Tag Block
b
Nos. 1.00 4,086.00 4,086

Supply of following size anealed tinned copper conductor PVC insulated


and sheathed armoured copper telephone cables with suitable clamps,
8.00 Non DSR saddles on existing cable trays / raceways etc and including making terminal
joints complete as required.

397
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

10 Pair
a
Metre 1,200.00 83.00 99,600

Supply , Erecting & Commissioning of Main Distribution Frame (MDF) box


indoor type with wall mounting facility having front door with lock and
suitable for following capacity along with aluminium frame for mounting
9.00 Non DSR
krone modules. Complete cabinet fabricated from 18SWG CRCA Sheet with
powder coated in approved manner

200x200pairs
a set 1.00 20,929.00 20,929

Total SH 06- TELEPHONE SYSTEM


838,280

SH-07 FIRE ALARM SYSTEM

Wiring in existing conduit : Supplying and drawing following sizes of FR PVC


insulated copper conductor , single core cable in the existing
1.00 DSR - 1.17
surface/recessed Steel /PVC conduit as required.

DSR - 2 x 1.5 sq.mm


a
1.17.2 Metre 20,880.00 36.00 751,680
DSR - 3 x 1.5 sq.mm
b
1.17.3 Metre 2,000.00 50.00 100,000

S/F Steel conduit : Supplying and fixing of following sizes of Steel conduits
along with accessories in surface/ recess including painting in case of
2.00 DSR – 1.20 surface conduit,or cutting the wall and making good the same in case of
recessed conduit as required.

DSR – 20mm
a
1.20.1 Metre 800.00 121.00 96,800

398
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DSR – 25mm
b
1.20.2 Metre 18,240.00 142.00 2,590,080
DSR – 32 mm
c
1.20.3 Metre 200.00 193.00 38,600

Laying of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables including


DerivedDS
3.00 excavation,supply & fiiling of sand and bricks .
R – 7.3.1
Metre 500.00 75.00 37,500

Layingof 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng hume pipes.
Derived
4.00
DSR – 7.5.1
Metre 200.00 15.00 3,000

Laying of of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables on surface


Derived including supply and fixing of G.I. Spacer, saddles etc.
5.00
DSR – 7.7.1
Metre 200.00 25.00 5,000

Laying of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng laid


DerivedDS
6.00 Concealed/Surface conduits, cables trays.
R – 7.8.1
Metre 22,000.00 25.00 550,000

Supply, Installation, Testing & Commissioning of Analog Addressable type Self


Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting
base, LED, Address Switch, complete with MS Powder coated Junction Box for
7.00 NON -DSR
mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends,
cable compression glands, cable tags and Ferruling. (BFC)
Nos 553.00 5,200.00 2,875,600

Supply, Installation, Testing & Commissioning of Analog Addressable type Self


Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting
base, LED, Address Switch, complete with MS Powder coated Junction Box for
8.00 NON -DSR
mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends,
cable compression glands, cable tags and Ferruling. (AFC)
Nos 506.00 5,200.00 2,631,200

399
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Analog addressable Rate of
Rise Cum Fixed temperature detector with standard mounting base, LED,
Address Switch, complete with MS Powder coated Junction Box for mouting
9.00 on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.
Nos 85.00 4,400.00 374,000

Supply, Installation, Testing & Commissioning of Response Indicator with


matching screws complete with GI Junction box, Cable lugs at cable end
10.00 and ferruling.
Nos 506.00 118.00 59,708

11.00 Devices

Supply, Installation, Testing & Commissioning of Addressable Dual Action


Manual Pull Station with Adddress Switch and all mounting accessories ,
11.01 complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 36.00 6,700.00 241,200

Supply, Installation, Testing & Commissioning of Fireman's Phone Jackwith all


mounting accessories, complete with MS Powder coated Junction Box for
11.02 mounting on Surface, Cable Lugs at Ends and all required accesories for
mounting at site complete as requried.
Nos 36.00 5,000.00 180,000

Supply, Installation, Testing & Commissioning of Addressable Module for Fire


Phone Jack with Adddress Switch and all mounting accessories, complete
11.03
with MS Powder coated Junction Box for mouting on Surface, Cable lugs at
Ends, cable compression glands, cable tags and Ferruling. Nos 36.00 5,800.00 208,800

400
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Addressable Relay Module
with Address Switch and all mounting accessories complete as required.
Shall be complete with Pilot Relay for Tripping of Third Party Equipment,
11.04 suitable for switching 5A/15A current through the Relay contacts , MS Powder
coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.
Nos 10.00 5,800.00 58,000

Supply, Installation, Testing & Commissioning of Addressable Control Module


with Address Switch and all mounting accessories, complete with MS Powder
11.05 coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling. Nos 72.00 5,800.00 417,600

Supply, Installation, Testing & Commissioning of Fault Isolator Module ,


11.06 complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling. Nos 100.00 5,100.00 510,000

Supply, Installation, Testing & Commissioning of Directional Sounders with


20Hz to 20 KHz operating frequency with minimum 8 distinct sound patterns
to indicate Exit doors and direct occupants for safe and fast evacuation ,
11.07
complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 36.00 21,000.00 756,000

Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Voice


11.08 Evacuation Speaker having power taps upto 2W and frequency response of
400 to 4000Hz for Voice Evacuation.
Nos 212.00 2,300.00 487,600

Supply, Installation, Testing & Commissioning of Wall Mounted Voice


11.09 Evacuation Speaker having power taps upto 2W and frequency response of
400 to 4000Hz for Voice Evacuation.
Nos 55.00 5,400.00 297,000

Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Muli-


11.10 Candela Strobe with all required accessories for mounting complete as
required. Nos 36.00 6,800.00 244,800

Control And Annunciation


12.00

401
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Microprocessor based 10
loop capacity , Networkable Analogue Addressable type Fire Alarm Control
panel.

The FACP shall have minimum 640 character Display with fully functional
QWERTY Keypad. Each loop shall have a maximum loading of 125 detectors
and 125 devices in one loop with 20% spare capacity. Four access levels,
flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts
sealed lead acid batteries sufficient for 24 hours normal working and for 2
hours during an emergency conditions as required. The FACP shall be UL 9th
12.01 Edition Listed. FACP should be with Network Communication Module with
true peer to peer Connectivity.

Failure of Fire Alarm Panel CPU shall not result in failure of operation of
Amplifiers. Hence if the Digital Audio Amplifiers are CPU Rail Mounted,
consider 1 No. CPU dedicated for Digiital Audio Amplifier Bank.

FACP cost to include all necessary cards, modules, enclosure, CPU and
associated acccessories to complete the system design. All components
including enclosures shall be UL Listed.
Nos 1.00 971,500.00 971,500

402
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Network Control Annunciator
for Fire Command Station with Digital Voice Command Centre with 2 way
Fire Fighters Communication System.

The DVC shall have an Integrated 8 Channel Digital Audio Command Centre
with a capacity to communicate and transmit pre-recorded and paging
messages through the Digital Audio Amplifiers distributed across various floors
of the building on a Digital Audio Loop with zone control function and other
accessories required to complete the system. The System shall have minimum
of 24 Zone Selection Switched.

The Network Control Annunciater and Digital Voice Command Centre shall
be enclosed in the same enclosure and both shall act as independent nodes
12.02 on the true peer to peer network.

The Networked Annunciater shall have minimum 640 character backlit LCD
display with QWERTY keypad, control interface and "soft" and "hard" keys.

The NCA shall have control and display capabilities for all nodes on the
network.

NCA shall be capable to select any zone to relay voice evacution message
from the fire command station.

Voice Command Center shall have a true Network Communication Module


with true peer to peer Connectivity. Nos 1.00 542,690.00 542,690

Supply, Installation, Testing & Commissioning Networkable Reapter Panel


with 640 Character Backlit LCD Display and fixed function Keys and Soft Keys.
12.03
Reapter Panel should be on true peer to peer network.
Nos 1.00 230,000.00 230,000

Supply, Installation, Testing & Commissioning of Digital Audio Amplifier / Zone


Amplifier capable of processing 1 of 8 audio channels and total of 100W at
70.7 VRMS output along with necessary enclosures. The DAA shall be fully
12.04
monitored for fault and alarm reporting. Power Amplifiers shall not be
permitted. UL Listed.
Nos 5.00 304,600.00 1,523,000

403
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Power Supply Unit - 240VAC
12.05 to 24VDC - 6Amps. Power Supply shall be UL Listed with Necessary Battery
Backup.
Nos 1.00 64,700.00 64,700

13.00 Cabling
Providing, testing and installing / fixing of approved make 20 mm dia.MS
13.01 Non DSR flexible conduits on ceiling / wall / floor etc. complete with accessories like,
Junction boxes, Collars, Bends etc.
metre 500.00 60.00 30,000

Total SH 07- Fire Detection & Alarm System


16,876,058

SH-08 DATA NETWORKING

HOSTEL BLOCK
SH-09 A

LAN SYSTEM
1.00

Supplying & laying of PVC sheathed flame retardant Untwisted Pair


1.01 (Untwisted Pair (UTP)) Cable of Cat - 6 back bone cable for Data & .
Mtr 4,000.00 53.00 212,000

Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6


1.02 RJ-45 information outlet module for Data .
Each 220.00 550.00 121,000

Supplying, installing, testing and commissioning of 24 Port Cat - 6 Untwisted


1.03 Pair (UTP) Patch Panel for Data Networking for back bone cable.
Each 10.00 17,050.00 170,500

Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6


1.04 Patch Cord of following length. 7ft
Each 218.00 415.00 90,470

Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6


1.05 Patch Cord of following length. 4ft
Each 436.00 350.00 152,600

404
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply installation testing and commissioning 2- Port Mosaic Faceplate -
1.06
White Each 111.00 220.00 24,420

1.07 Supply installation testing and commissioning Blank Insert For Faceplate Each 111.00 600.00 66,600

INDOOR ACCESS POINT


2.00

Supply & Installation of dual-band (5 GHz and 2.4 GHz concurrent) Mid-
Range 802.11n (300Mbps) Wireless Access Point with PoE (802.3af) support/
2.01 capability. These AP's should be capable of being used with inline & external
power source (Thin & thick AP), with Mounting brackets.
Each 20.00 44,580.00 891,600

WIRELESS CONTROLLER
3.00

Supply & Installation Testing and commissioning of Premium Mobility


Controller Includes support for 10 AP (max 40) and 250 Access Controlled
users. Support premium package (including teaming and MTM), 4
3.01 10/100/1000
ports, 2 dual SFP ports

Each 1.00 565,800.00 565,800

4.00 Server & Wall mount Rack and cable management

Supply installation testing and commissioning of 600 mm x 600 mm 15 U


230 V AC 90 CFM fan 2 , three Hardware packet 1 set ( containing 20 Nos
4.01
each of 3), stationary shelf , Two Cable manager 1U height.
Each 4.00 21,750.00 87,000

Supply installation testing and commissioning of 600 mm x 1000 mm 42 U


230 V AC 90 CFM fan 2 , three Hardware packet 1 set ( containing 20 Nos
4.02
each of 3), stationary shelf , Two Cable manager 1U height. Varitical cable
manager . Each 1.00 99,875.00 99,875

Supply installation testing and commissioning 1U Horizontal Cable Manager


4.03 (For Field Cables & Switches)
Each 5.00 885.00 4,425

405
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Supply installation testing and commissioning 6 / 12 Socket Universal Power


4.04 Strip with MCB
Each 6.00 3,000.00 18,000

Supply installation testing and commissioning Extra Hardware packets for


4.05 300.00
Racks Each 3.00 900

Supply installation testing and commissioning Labels for 4-pair Patch Cords
4.06 (70 labels per sheet)
Set 1.00 375.00 375

EDGE SWITCHES
5.00

Supply installation testing and commissioning 24 Port 10/100/1000Mbps + 2


ports for optional SFP/ SX Modules supporting 1G, layer 2 switch with
5.01 Stacking cable (Non-blocking switch fabric, IPv6 ready), option for RPS
Each 10.00 88,125.00 881,250

POE SWITCHES
6.00

Supply installation testing and commissioning b 48 Port 10/100/1000Mbps


PoE + 2 ports for optional SFP/ SX Modules supporting 1G, layer 2 switch
6.01 with Stacking cable (Non-blocking switch fabric, IPv6 ready), option for RPS
(Should have per port power budget of 15.4W, when fully populated)
Each 1.00 84,650.00 84,650

Supply installation testing and commissioning Multi-Mode SFP /SX


6.02 transceivers supporting 1G
Each 4.00 21,750.00 87,000

Total SH 08 - Data Networking


3,558,465

406
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-09 TV SYSTEM

Supplying and fixing following modular switch/ socket on the existing


1.00 DSR-1.24 modular plate & switch box including connections but excluding modular
plate etc. as required.

TV antenna socket outlet


a DSR-1.24.7
Each 100.00 93.00 9,300

Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
recessed steel/ PVC conduit as required.
2.00 DSR - 1.53
Metre 3,500.00 33.00 115,500

Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
3.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.

DSR - 25mm
a Metre
1.21.2 2,800.00 65.00 182,000
DSR - 32mm
b Metre
1.21.3 150.00 32.00 4,800

Total SH 09- TV System 311,600

407
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATED COST OF ELECTRICAL WORKS (RESIDENTIAL BLOCK 1 & 2)

SUBHE AD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

A. RESIDENTIAL BLOCK 1 & 2

SH-01 POINT WIRING AND ACCESSORIES: 6,627,536


SH-02 MV PANELS & DISTRIBUTION BOARDS 5,048,595
SH-03 EARTHING SYSTEM 545,192
SH-04 LIGHTNING PROTECTION SYSTEM 315,708
SH-05 LIGHT FIXTURES AND FANS: 6,040,902
SH-06 TELEPHONE SYSTEM 765,172
SH-07 FIRE ALARM SYSTEM 12,293,554
SH-08 DATA NETWORKING 535,820
SH-09 TV System 684,154
SUB TOTAL (A) 32,856,633

LESS 5% FOR UPRNN WORKING (1,642,832)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 31,213,801

408
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DETAILED COST ESTIMATE FOR ELECTRICAL WORKS : RESIDENTIAL BLOCK 1 &2

SH-01 POINT WIRING AND ACCESSORIES:

Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable in surface /
1.00 DSR - 1.3 recessed steel conduit, with modular switch, modular plate, suitable GI box
and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor
single core cable etc as required.

Group A(Hostel, Residential)


a DSR - 1.3.1
Point 2,433.00 677.00 1,647,141
-
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed steel conduit, 2 way
2.00 DSR - 1.4 modular switch, modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as
required. Point 40.00 1,069.00 42,760
-
Wiring for circuit/ submain wiring along with earth wire with the following sizes
3.00 DSR -1.7 of FRLS PVC insulated copper conductor, single core cable in surface/
recessed steel conduit as required
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b DSR - 1.7.2
Metre 174.00 200.00 34,800
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c DSR - 1.7.3
Metre 231.00
80.00 18,480
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d DSR - 1.7.4
Metre 150.00 315.00 47,250
-
Wiring for light/power plug with 2X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
4.00 DSR – 1.12 along with 1 no. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required.(RawPower)
Metre 12,260.00 162.00 1,986,120

409
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Wiring for light/power plug with 4X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
along with 2 nos. 4sq.mm., FRLS PVC insulated, copper conductor single core
5.00 DSR – 1.13
cable for loop earthing as required.(RawPower)

Metre 3,500.00 275.00 962,500


Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes
of FRLS PVC insulated, copper conductor,single core cable in
6.00 DSR – 1.14 surface/recessed medium class PVC conduit as required.

-
DSR – 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
a
1.14.1 Metre 3,750.00 106.00 397,500
DSR – 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
b
1.14.2 Metre 225.00 131.00 29,475
c DSR-1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Metre 65.00 162.00 10,530
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d DSR-1.14.4
Metre 130.00 221.00 28,730
Supplying and drawing following sizes of FRLS PVC insulated copper
7.00 DSR-1.17 conductor, single core cable in the existing surface/ recessed steel/ PVC
conduit as required.
--
1 x 1.5 sq. mm
a DSR-1.17.1
Metre 65.00 22.00 1,430
2x 1.5 sq. mm
b DSR-1.17.2
Metre 65.00 36.00 2,340
3x 1.5sq. mm
c DSR-1.17.3
Metre 64.00 50.00 3,200
4x 1.5 sq. mm
d DSR-1.17.4
Metre 45.00 63.00 2,835
DSR- 2 x 2.5 sq. mm
e
1.17.11 Metre 15.00 53.00 795
DSR- 2 x 4 sq. mm
f
1.17.20 Metre 30.00 77.00 2,310
DSR- 2 x 4 sq. mm
g
1.17.21 Metre 12.00 109.00 1,308
-
-

410
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing of following sizes of steel conduit along with accessories
in surface/recess including painting in case of surface conduit, or cutting the
8.00 DSR-1.20 wall and making good the same in case of recessed conduit as required.

-
-
20 mm
a DSR-1.20.1
Metre 12.00 121.00 1,452
25 mm
b DSR-1.20.2
Metre 60.00 142.00 8,520
32 mm
c DSR-1.20.3
Metre 30.00 193.00 5,790
40 mm
d DSR-1.20.4
Metre 22.00 287.00 6,314
50 mm
e DSR-1.20.5
Metre 20.00 387.00 7,740
-
Supplying and fixing of following sizes of medium class PVC conduit along
with accessories in surface/recess including cutting the wall and making
9.00 DSR-1.21 good the same in case of recessed conduit as required.

20 mm
a DSR-1.21.1
Metre 60.00 53.00 3,180
25 mm
b DSR-1.21.2
Metre 150.00 65.00 9,750
32 mm
c DSR-1.21.3
Metre 100.00 85.00 8,500
40 mm
d DSR-1.21.4
Metre 60.00 110.00 6,600
50 mm
e DSR-1.21.5
Metre 30.00 144.00 4,320
-

411
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing metal box of following sizes (nominal size) on surface or
in recess with suitable size of phenolic laminated sheet cover in front
10.00 DSR-1.22 including painting etc as required.

75 mm X 75 mm X 60 mm deep
a DSR-1.22.1
Each 50.00 89.00 4,450
150 mm X 75 mm X 60 mm deep
c DSR-1.22.3
Each 12.00 111.00 1,332
150 mm X150 mm X 60 mm deep
c DSR-1.22.4
Each 50.00 160.00 8,000
-
Supplying and fixing following modular switch/ socket on the existing
modular plate & switch box including connections but excluding modular
11.00 DSR-1.24
plate etc. as required.
-
-
5/6 amps switch
a DSR-1.24.1
Each 455.00 81.00 36,855
2 way 5/6 amps switch
b DSR-1.24.2
Each 12.00 96.00 1,152
15/16 amp switch
c DSR-1.24.3
Each 513.00 111.00 56,943
3 pin 5/6 amp socket outlet
d DSR-1.24.4
Each 1,029.00 79.00 81,291
6 pin 15/16 amp socket outlet
e DSR-1.24.5
Each 513.00 150.00 76,950
Telephone socket outlet
f DSR-1.24.6
Each 64.00 95.00 6,080
TV antenna socket outlet
g DSR-1.24.7
Each 300.00 94.00 28,200
Bell push
h DSR-1.24.8
Each 60.00 111.00 6,660
-

412
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
S/F Modular Type Blanking Plate : Supplying and fixing modular blanking
12.00 DSR - 1.26 plate ,on the existing modular plate & switch box excluding modular plate
etc. as required.
Each 30.00 23.00 690
-
S/F GI Box along with modular plate: Supplying and fixing following size
/modules, GI box along with modular base & cover plate for modular
13.00 DSR – 1.27
switches in recess etc as required.
-
-
DSR – 1 or 2 Module(75mmx75mm)
a
1.27.1 Each 1,633.00 166.00 271,078
3 Module (100mmX75mm)
b DSR-1.27.2
Each 1,477.00 175.00 258,475
4 Module (125mmX75mm)
c DSR-1.27.3
Each 23.00 195.00 4,485
-
Supply & fixing following modular base and cover plate for modular
14.00 DSR - 1.28 switches in recess etc as required.
-
-
DSR -
1 or 2 Module
a
1.28.1 Each 79.00
1,633.00 129,007
DSR -
3 Module
b
1.28.2 Each 88.00
1,477.00 129,976
DSR -
4 Module
c
1.28.3 Each 97.00
23.00 2,231
-
Supplying and fixing 3 pin, 5 amp ceiling rose ,on the existing junction box
15.00 DSR - 1.33 including connection etc. as required.
Each 200.00 43.00 8,600
-
Supplying and fixing brass batten/angle holder including connection etc. as
16.00 DSR - 1.34 required.
Each 25.00 74.00 1,850
-

413
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
17.00 DSR - 1.36 including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.
Each 80.00 163.00 13,040
-
Supplying and fixing stiff pendent with 600 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
18.00 DSR - 1.37 including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.
Each 35.00 163.00 5,705
-
Supplying and fixing call bell/ buzzer suitable for single phase,230 Volts,
19.00 DSR - 1.38 complete as reqired.
Each 65.00 61.00 3,965
-
Providing and fixing 16/0.20mm (0.50sqmm) twin flat flexible,FRLS PVC
insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or
20.00 DSR - 1.39
side of the table/ door etc. as required.
Each 35.00 21.00 735
-
Providing and fixing 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC
insulated, PVC sheathed copper cable direct on the wall with PVC clips etc.
21.00 DSR - 1.40 .
as required.
Each 35.00 19.00 665
-
Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug
DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
22.00
minus1.20. insulated, copper conductor single core cable for loop earthing as
1) required.(UPS Power)
Metre 15.00 107.00 1,605
-
Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug
DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
23.00
minus1.20. insulated, copper conductor single core cable for loop earthing as
1)
required.(RawPower)
Metre 50.00 107.00 5,350
-

414
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Wiring for the following light points with 1.5 sq.mm PVC insulated
copper conductor 1100 volts grade stranded flexible FRLS wires of
approved make in concealed or surface mounted 25 mm dia medium
24.00 DRDSR class PVC conduit controlled by SPMCB provided in the DB and earthing of
fixtures with 1.5 sq.mm PVC insulated copper conductor stranded flexible
FRLS wire.(Cost of MCB not to be included here)
-
a One point controlled by one MCB.
Points 18.00 228.00 4,104
b Two points controlled by one MCB.
Points 8.00 456.00 3,648
c Three points controlled by one MCB.
Points 18.00 684.00 12,312
d Four points controlled by one MCB.
Points 13.00 912.00 11,856
e Five points controlled by one MCB
Points 41.00 1,140.00 46,740
f Six points controlled by one MCB.
Points 26.00 1,368.00 35,568
g Seven points controlled by one MCB.
Points 5.00 1,596.00 7,980
h Eight points controlled by one MCB.
Points 3.00 1,824.00 5,472
I Nine points controlled by one MCB.
Points 23.00 2,052.00 47,196
j Ten points controlled by one MCB.
Points 4.00 2,280.00 9,120
-
Supplying and fixing 250x150x75 mm deep, 1.6 mm thick G I Junction box
25.00 NON DSR with coverplate complete as per site requirement.
Nos 33.00 500.00 16,500
-
TOTAL FOR SH-01 - POINT WIRING AND ACCESSORIES: 6,627,536

SH-02 MV PANELS & DISTRIBUTION BOARDS


Providing and fixing following rating and breaking capacity MCCB in existing
cubicle panel board including drilling holes in cubicle panel, making
1.00 DSR - 2.2
connections, etc. as required.

100 Amp, 16 KA, TP MCCB


a DSR - 2.2.1
Each 2.00 3,205.00 6,410

415
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.00 DSR - 2.3 S/F prewired SP MCB DB : Supplying and fixing following way single pole and
neutral,sheet steel MCB distribution board 240 volt,s on surface/recess,
complete with tinned copper bus bar , neutral bus bar , earth bar , din bar ,
interconnections , power painted including earthing etc. as required .(But
without MCB/RCCB/Isolator ).
-
a DSR - 2.3.5 2+4 way /6 Way ,Double Door Each 923.00
1.00 923
b DSR - 2.3.6 2+6 Way / 8 Way,Double Door Each 1,041.00
1.00 1,041
c DSR - 2.3.7 2+8 Way / 10 way,Double Door Each 1,132.00
1.00 1,132
S/F prewired TP MCB DB : Supplying and fixing following way prewired TP&N
MCB distribution board of steel sheet for 415 volts on surface/recess,
complete with loose wire box, terminal connectors for all incoming and
outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper
3.00 DSR - 2.8
conductor up to terminal blocks , tinned copper bus bar , neutral link , earth
bar , din bar , detachable gland plate , interconnections , power painted
including earthing etc. as required .(But without MCB/RCCB/Isolator ).
-
4 way (4 + 12 ),Double Door
a DSR – 2.8.5
Each 1.00 7,357.00 7,357
6 way (4 + 18 ),Double Door
b DSR – 2.8.6
Each 25.00 9,496.00 237,400
8 way (4 + 24 ),Double Door
c DSR – 2.8.7
Each 110.00 10,405.00 1,144,550
12 way (4 + 36 ), Double Door (LPDB)
d DSR – 2.8.8
Each 4.00 12,782.00 51,128
S/F 'C' Curve , SP MCB : Supplying and fixing 5 amps to 32 amps, rating,
240/415 volts, 'C' Curve , miniature circuit breaker suitable for inductive load
4.00 DSR - 2.10 of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required. -
DSR - Single Pole
a
2.10.1 Each 2,840.00 169.00 479,960
DSR - Single Pole and Neutral
b
2.10.2 Each 75.00 441.00 33,075

416
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
S/F SP MCB blanking plate : Supplying and fixing single pole blanking plate in
5.00 DSR - 2.11 the existing MCB DB complete etc.as required.
Each 39.00 7.00 273
S/F DP MCB isolator : Supplying and fixing following rating, double pole , 240
6.00 DSR - 2.12
volts, isolator in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
-
DSR - 40 amps
a
2.12.1 Each 4.00 218.00 872
S/F FP MCB isolator : Supplying and fixing of following rating, four pole , 415
7.00 DSR - 2.13 volts, isolator in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
-
DSR - 40 amps
a
2.13.1 Each 21.00 659.00 13,839
DSR - 63 amps
b
2.13.2 Each 115.00 670.00 77,050
S/F SPN RCCB :Supplying and fixing following rating, double pole, (single
phase and neutral), 240 volts, residual current circuit breaker (RCCB), having
8.00 DSR - 2.14
a sensitivity current upto 300 milliamperes in the existing MCB DB complete
with connections, testing and commissioning etc. as required. -
DSR -
25 amps
a
2.14.1 1,645.00
Each 64.00 105,280
DSR -
40 amps
b
2.14.2 Each 227.00 1,714.00 389,078
-
Supplying and fixing following rating, four pole, (three phase and neutral),
415 volts, residual current circuit breaker (RCCB), having a sensitivity current
9.00 DSR - 2.15 upto 300 milliamperes in the existing MCB DB complete with connections,
testing and commissioning etc. as required.
-
40 amps
DSR -
a
2.15.2
Each 1.00 1,714.00 1,714
63 amps
DSR -
b
2.15.3 Each 2,237.00
1.00 2,237
-

417
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
Supplying and fixing DP sheet steel enclosure on surface/ recess along with
16/25/32amps 240 volts "C" curve DP MCB complete with connections, testing
10.00 DSR - 2.16
and commissioning etc. as required.
Each 1.00 617.00 617
-
Supplying and fixing TP sheet steel enclosure on surface/ recess along with
16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing
11.00 DSR - 2.17
and commissioning etc. as required.
Each 2.00 868.00 1,736
-
S/F 20 A SPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 240
Volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed
plug top along with 20 Amps, C-Curve, SP MCB, in sheet steel enclosure, on
12.00 DSR - 2.18 surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.

Each 4.00 954.00 3,816


-
S/F 20 A TPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 20 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
13.00 DSR - 2.19 surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.

Each 2.00 1,967.00 3,934


-
S/F 30 A TPN MCB industrial socket outlet : Supplying and fixing 30 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 30 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
14.00 DSR - 2.20
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 1.00 2,473.00 2,473
-

418
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying,Installation, testing and commissioning of cubical type LT panel
suitable for 415V, 3 Phase,4 wire 50 Hz AC supply system fabricated in
compartmentalized design from CRCA sheet steel of 2mm thick for frame
work and covers, 3mm thick for gland plates i/c cleaning & finishing
completed 9 tank process of powder coating in approved shade,having
extensible type TPN Aluminium alloy bus bars of high conductivity,DMC/SMC
bus bar supports,with short circuit withstand capacity for 1 sec, bottom base
channel of MS section not less that 100 mm x 50mm x 5mm thick, fabrication
15.00 shall be done transportable sections,entire panel shall have a common
copper earth bar of size 25mmx5mm at the rear with 2 no's earth stud,solid
connections from main bus bar to switchgears with required size of
alunimium bus bars and control wiring PVC insulated copper conductor S/C
cable alleys,cable gland plates in two half,i/c providing following switch
gears: (with all necessary hardware, accessories as required for complete
installation as per specifications and single line digram).
-
-
Refer CPWD general specification for Electrical works Part IV Sub station

-
Note: 1.Provision for both Bottom & Top cable entry shall be provided in All
Panels .
-
-
All panles shall be indoor type unless otherwise mentioned. Only feeder pillers
shall be outdoor type.
-

MV PANELS -
General Notes: -
-
ACB:
A. -
-
LSIG (Microprocessor Based) releases shall be used for incoming feeders such
as Transformers and DG Sets & LSI releases for outgoing breakers. All ACB
i
shall have Icu = Ics = Icw for 1 Second.
-
-

419
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
All 4 Pole ACB shall have fully Rated neutral equal to rating of the breaker &
ii shall be protected against overload & short-circuit .

-
-
Ready-to-close contact shall exist for indicating that all safety parameters
iii are checked & enabling closure of breaker, ensuring at-most safety for the
user
-
-
A door interlock shall be provided so that it shall not be possible to open the
iv door until the air circuit breaker moving part is in the disconnected position.
-
-
MCCB:
B. -
-
All MCCBs shall be suitable for 3 Phase 415 Volts AC 50 HZ supply
i.
-
-
All MCCBs shall have rated service breaking capacity (Ics) equal to the
ii. ultimate breaking capacity (Icu) at defined operational voltage.
-
-
All MCCBs shall clearly indicate the suitability for isolation in the name plate
iii. identified by the symbol
-
-
All MCCBs shall offer class –II front face i.e. main current path of the circuit
iv. breaker should be isolated from auxiliary section
-
-
All Incomer MCCBs shall be provided with earth fault protection
v.
-
-
MCCBs of above250A Microprocessor Based and upto 250A thermal
vi. Magnetic releases.
-
-

420
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
This BOQ to be read in conjunction with technical specifications and Single
Line Diagram (attached for reference). If any discrepancy occurs that should
vii. be brought to the notice of Client/Consultant before quoting the price
otherwise stringent condition will be deemed to have been considered.
-
-
All ACBs to be provided with ON/OFF/Trip lamps, 3 NO + 3NC Auxiliary
viii. contacts other than used in control circuit.
-
-
All Transformer and DG incoming ACBs shall be provided with Microprocessor
ix. based releases & ON/OFF/Trip / Spring charged/ready to close indicating
lamps.
-
-
All MCCBs shall be provided with rotary operating handle and ON/OFF lamps
x. backed by 2Amp control MCB.
-
-
All meters shall be digital type (unless otherwise specified)
xi. -
-
Multi-function meter to be provided as required to cover all the parameters
xii. as mentioned.
-
-
All current/voltage transformer shall be cast resin type.
xiii.
-
-
All indicating lamps shall be LED type.
xiv. -
-
Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus
xv. bar is after considering all derating factors. (Bus bar sizing calculation to be
submitted for approval.)
-
-
All internal control wiring shall be heat resistant type.
xvi. -
-
All incoming breakers in Main LT panel shall be electrically interlocked.
xvii.
-

421
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
All TP feeders shall be provided with Isolable neutral link.
xviii.
-
-
Bus bar chamber shall be provided at top only. Incoming and outgoing
xix. cable entry shall be from top/bottom as required.
-
-
Bus couplers in Main MV Panel shall be Microprocessor based with all
xx.
releases. -
-
Bus couplers shall be provided with ON & OFF indicating lights but without
xxi. releases.
-
-
All feeders shall be provided with door interlocked with door defeat, pad
xxii. lock facility.
-
-
Live parts shall not be accessible after opening the door, Transparent acrylic
xxiii. sheet to be provided to cover the same.
-
-
Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto
xxiv. terminal block.
-
-
xxv. 20% spare control terminal to be provided. -
-
All MCCBs shall be provided with variable O/L & S/C releases. Incoming
xxvi. MCCB shall be provided with E/F releases also
-
-
All incoming/outgoing cables shall be terminated on links/terminals.
xxvii.
-
-
xxviii. All Panels shall have 100 % Neutral Bus Bar Rating.
-
-

422
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Degree of protection for following type of distribution panel enclosure shall
xxix. be as per IS: 13947-1993.
-
-
IP 43 for indoor panels.
-
IP 55 for outdoor panels.
-
-
Painting/lettering on Breakers and distribution boards, the location they
xxx. serve, providing on each panel its circuit diagram.
-
-
-
15.01 RESIDENTIAL BLOCK PANELS
-
-
15.01.1 Non DSR MAIN LT PANEL (RESXIDENTIAL BLOCK 1 & 2)
-
Incomer
-
-
800A 4P MDO ACB,50 KA(microprocessor based )
-
-

Metering & Indication:


-
Each Shall have
-
Multifunction Digital meter (consisting of Voltage, Amps, kWh, kW, P.F.
parameter) with RS 485 Port.
-
-
Breaker ON / OFF / TRIP indicating lights with control MCB’s.
-
Set of RYB phase indicating lamps with 2A control MCBs.
-
-
Busbar
-
1000A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).
-

423
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Outgoings:
-
-
Set of RYB phase indicating lamps with 2A control MCBs on each outgoing
to be provided.
-
Each Outgoing shall be provided with 3-phase digital type energy meters
with Communication Port.
-
-
Ten (10) Nos. 63 A 4P MCB (10KA)
-
Two (2) Nos. 630 A TP MCCB (25KA)
-
Two (2) Nos. 125 A TP MCCB (25KA)
Set 1.00 626,700.00 626,700

Lift Panel (RESXIDENTIAL BLOCK 1 & 2)


15.01.2 Non DSR
-
-
Incoming (1 No.):
-
-
100Amp TP+N MCCB, 25kA
-
-
Metering & Indication:
-
(0-500) volts digital voltmeter with selector switch protected by 2A control
MCB's -
-
(0-100A) Digital ammeter with Selector Switch and 100/5 amps Cl-1, 5VA CT's
-
-
Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.
-
-
Bus Bars:
-
160A, TPN aluminium , colour coded Sleeved bus bars suitable for 415V, 50Hz.
(after deration) -
-

424
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Outgoings
-
Phase indicating lamps with 2A Control MCB shall be provided on each
outgoing.
-
1 Nos. 40A 4P MCB (10 KA) -
2 Nos. 40A 4P RCBO (30 mA,10 KA) Set 2.00 78,500.00 157,000

15.01.3 Non DSR MDB (RESXIDENTIAL BLOCK -Typical)


-
Incomer
-
100 A TP MCCB,25 KA
-
Metering & Indication:
-
Each Shall have
-
Breaker ON / OFF / TRIP indicating lights with control MCB’s.
-
Set of RYB phase indicating lamps with 2A control MCBs.
-
-
Busbar
-
160 A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).
-
Outgoings:
-
Four(4) Nos 3 Phase Dual & Digital Type Energy Meters
-
Four (4) Nos. 63 A 4P MCB (10KA)
Set 14.00 121,000.00 1,694,000
-
Supply & Fixing of Four Pole 63 A Manual Change over Switch with Powder
16.00 Non DSR Coated Matalic Encloser as required.
Each 1.00 5,000.00 5,000
-
TOTAL FOR SH-02 - MV PANELS & DISTRIBUTION BOARDS:
5,048,595

425
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-03 EARTHING SYSTEM

G.I. earth plate electrode : Earthing with GI earth plate 600mm X 600mm X 6
mm thick including accessories and providing masonary enclosure with
1.00 DSR - 5.4 cover plate having locking arrangement and watering pipe of 2.7 metre
long etc. with charcoal/coke and salt as required.
Set 10.00 4,490.00 44,900
-
Copper earth plate electrode : Earthing with Copper earth plate 600mm X
600mm X 3 mm thick including accessories and providing masonary
2.00 DSR - 5.6 enclosure with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/coke and salt as required.
Set 6.00 9,292.00 55,752
-
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground
as strip earth electrode, including connection/ terminating with G.I. nut, bolt,
3.00 DSR - 5.8 spring, washer etc. as required. (Jointing shall be done by overlapping and
with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Metre 35.00 753.00 26,355
-
Supplying and laying 25mm x 5 mm GI strip at 0.50 m below ground as strip
earth electrocde, including connection/terminating with G.I. nut, bolt, spring,
4.00 DSR - 5.9 washer etc. as required. (Jointing shall be done by overlapping and with 2
sets of G.I nut bolt & spring washer sapced at 50mm).
Metre 350.00 109.00 38,150
-
Providing & Fixing 25mm x 5 mm Copper strip in 40 mm dia G.I. Pipe from
earth electrode including connection with brass nut, bolt, spring, washer
5.00 DSR - 5.10
excavation and re-filling etc. as required.
Metre 35.00 1,082.00 37,870
-
Providing & Fixing 25mm x 5 mm G.I. Strip in 40 mm dia G.I. pipe from earth
electrode including connection with G.I. nut, bolt, spring, washer excavation
6.00 DSR - 5.11
and re-filling etc. as required.
Metre 35.00 421.00 14,735
-

426
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and laying earth connection from earth electrode with 6 SWG dia
7.00 DSR - 5.12 G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection
with G.I. thimble excavation and re-filling as required.
Metre 35.00 151.00 5,285
-
Providing and fixing 6 SWG dia GI wire on surface or in recess for
8.00 DSR – 5.16 connections etc. as required.
Metre 15.00 35.00 525
-
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for
9.00 DSR - 5.20. connections etc. as required.
Metre 55.00 1,599.00 87,945
-
Supplying and fixing earth bus of 50mmx6mm GI strip on surface for
10.00 Non DSR connections etc as required.
Metre 55.00 350.00 19,250
-
60 mm x 10 ( or 50 x 12) mm x 1.2 mtrs length copper earth bus bar with
a MR insulators, making suitable size holes etc as required
Sets 30.00 2,500.00 75,000
-
60 mm x 10 ( or 50 x 12) mm x 1.2 mtrs length GI earth bus bar with insulators,
b MR making suitable size holes etc as required
Sets 30.00 2,500.00 75,000
-
c MR Providing and fixing OF 50 mm x 10 mm thick copper tape. RM 1,950.00
30.00 58,500
-
Providing and fixing 8 SWG GI wire.
d MR RM 175.00 18.00 3,150
-
Providing and laying GI tape 32 mm X 6 mm from earth electrode directly in
11.00 DR DSR ground as required.
Metre 15.00 185.00 2,775
-
TOTAL FOR SH-03 - EARTHING SYSTEM
545,192

427
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

LIGHTNING PROTECTION SYSTEM


SH-04
Lightning Arrestor:Supply, installation, testing and commissioning of External
Lightning wide area protection system based on Eaarly Streamer Emission
(ESE) technology. Device shall emit electromagnetic impulse in the form of a
streamer into the air microseconds earlier than naturally formed streamers.
1.00 Non DSR Device confirmg to NFC 17-102 and UNE 21186 Standards. Appropriate non
penetrating mounting arrangement. The device shall be mounted at
suitable clear to the highest point on the roof top. (Model selected shall give
coverage of 79 M radius @ min 5M height from terrace )
Each 1.00 154,800.00 154,800
Down conductor:Supply, installation, testing and commissioning of 70 Sqmm
2.00 Non DSR twisted 19-Strand, bare Cu cable on surface/wall / as per site requirement
and complete in all respect.
Metre 95.00 700.00 66,500
Lightning Counter :Supply and installation of counting the number of
3.00 Non DSR lightning strikes without any power supply.
Each 1.00 22,500.00 22,500
Maintenance Free Earthing:Supply, installation, testing and commissioning of
maintenance free electrolytic earthing system with 10 feet's rod, 2 inches dia,
2mm thick that does not require manual addition of water. The system should
be stable operation for at least 30 years. The electrode shall be electrolytic
grade copper rod pre-filled with hygroscopic powder and provided with
4.00 Non DSR suitable breathing and leaching ports at the ends. The electrode shall be
surrounded by suitable powdered form of backfill so as to provide maximum
contact between the electrode and the backfill. The earthing pit shall be
provided with suitable sturdy test well for observation. (The installation
procedures should be followed as instructed by the Earth Electrode Supplier).
Set 3.00 12,500.00 37,500
5.00 Non DSR Test Link :Supply and installation of test link in weather proof IP 65 BOX.
Each 3.00 2,500.00 7,500
Supply, installation, testing and commisioning of 2 x 25W LED Aviation
abstruction light medium bay type 62, complete with lamp, lamp holder,
Condenser necessary connecting wire, 1 X 25 AV with all necessary
6.00 Non DSR
hardware, accessories as required for complete installation. Rate shall
include the cost of necessary steel structures , fixing arrangements in this item.
Refer drawing. Each 1.00 13,908.00 13,908
Providing and fixing M.S.. tape 20 mm X 3 mm thick on parapet or surface of
7.00 Non DSR wall for lightning conductor complete as required .
metre 250.00 52.00 13,000

428
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
TOTAL FOR SH-04 - LIGHTNING PROTECTION SYSTEM 315,708
SH-05 LIGHT FIXTURES AND FANS:

S/F Modular Type Electronic Fan Regulator : Supplying and fixing stepped
type electronic fan regulator on the existing modular plate & switch box
1.00 DSR - 1.25
including connections but excluding modular plate etc. as required.
Nos 420.00 284.00 119,280
-
ITC fluoresent fitting directly on surface : Installation ,testing and
commissioning of pre-wired .fluorescent fitting /compact fluorescent fitting of
all types ,complete with all accessories and tube etc.directly on ceiling/wall
2.00 DSR - 1.41
,including connection with 1.5 sq.mm FRLS PVC insulated ,copper conductor
,single core cable and earthing etc.as required.
Nos 1,200.00 91.00 109,200
-
ITC fluoresent fitting on false ceiling : Installation ,testing and commissioning
of pre-wired .fluorescent fitting /compact fluorescent fitting of all types
DRDSR - ,complete with all accessories and tube etc.directly on ceiling/wall ,including
3.00
1.41 connection with 1.5 sq.mm FR PVC insulated ,copper conductor ,single core
cable and earthing etc.as required.
Nos 756.00 149.00 112,644
-
ITC Ceiling Fan : Installation ,testing and commissioning of ceiling fan
including wiring the down rods of standard length (upto 30 cm) with 1.5
4.00 DSR - 1.44
sq.mm FR PVC insulated ,copper conductor ,single core cable etc.as
required. Nos 400.00 95.00 38,000
-
Installation, testing and commissioning of ceiling fan, including wiring the
down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated,
5.00 DSR - 1.45 copper conductor, single core cable, including providing and fixing
phenolic laminated sheet cover on the fan box etc. as required.
Nos 15.00 122.00 1,830
-
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia,
heavy gauge including painting etc. as required. (Note : More than 5 cm
6.00 DSR - 1.47
length shall be rounded to the nearest 10 cm and 5 cm or less shall be
ignored) Nos 10.00 23.00 230
-

429
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm
dia, heavy gauge including painting etc. as required. (Note : More than 5
7.00 DSR - 1.48
cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be
ignored) Nos 14.00 27.00 378
-
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
8.00 DSR-1.49
Nos 736.00 26.00 19,136
-
Installation of exhaust fan in the existing opening, including making good the
9.00 DSR -1.50 damage, connection, testing, commissioning etc. as required.
-
-
DSR - Upto 450 mm sweep
a
1.50.1 Nos 300.00 204.00 61,200
-
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of
10.00 DSR -1.51 all sizes.
Nos 300.00 90.00 27,000
-
-
Supply of Wall Bracket Light aesthetic wall/ceiling mounted luminaire
suitable for 1 x TCH 14W , with low loss electronic ballast, 14W TCH lamp
11.00 NON DSR complete with all accessories etc as required. Philips make (Vector 14W TCH
207) or Bajaj Make - BTIP 114 ACR.
Nos 1,125.00 461.00 518,625
-
Supply of 1 x 18 W indoor decorative surface mounted/hanging LED light
fixtures suitable for 1 no. of 18W CFL lamps prewired complete with all
12.00 NON DSR
accessories required as per Bajaj Make BJDS 118 C WEB LX/18 W.
Nos 915.00 2,800.00 2,562,000
-
Supply of 1 x 28 W indoor decorative surface mounted/hanging FTL light
fixtures suitable for 1 no. of 28 W T5 lamp prewired complete with all
13.00 NON DSR
accessories required as per Philips Make Line Light GGx310 1 x 28 W TL5 EB O-
SAT. Nos 188.00 1,900.00 357,200
-
Supply of Bulk Head Light fixture with lamp complete with all accessories etc
14.00 NON DSR as required. Insta Power Bulkhead
Nos 10.00 1,800.00 18,000
-

430
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply of Mirror Light aesthetic wall/ceiling mounted luminaire suitable for 1
x TCH 14W , with low loss electronic ballast, 14W TCH lamp complete with all
15.00 NON DSR accessories etc as required. Philips make (Vector 14W TCH 207) or Bajaj
Make - BTIP 114 ACR.
Nos 125.00 461.00 57,625
-
Ceiling Fan : Supplying of capacitor type1200 mm sweep ceiling fan
complete with blades, shakle etc. with high breeze, high speed for operation
16.00 NON DSR on 230V, 50 Cy. Single phase A.C. supply confirming to IS 374-1979 and with
double ball bearing system The fan shall be green rated as per BEE norms.
Nos 571.00 1,593.00 909,603
-
Ceiling Fan : Supplying of capacitor type900 mm sweep ceiling fan complete
with blades, shakle etc. with high breeze, high speed for operation on 230V,
17.00 NON DSR 50 Cy. Single phase A.C. supply confirming to IS 374-1979 and with double
ball bearing system The fan shall be green rated as per BEE norms.
Nos 29.00 1,593.00 46,197
-
Supply and fixing of metal fan hook box of 10 mm M.S. round bar , bounded
to to RCC bar up to 50 mm length each side & pierced through a 16 SWG
18.00 NON DSR thick MS bowl 100 mm dia , depth up to 75 mm , complete erected in
position . With one coat of red oxide paint and 2 coats of synthetic paint .
Nos 554.00 301.00 166,754
-
19.00 NON DSR Exhaust fan of 450mm dia. 900rpm single phase heavy duty.
Nos 4.00 4,000.00 16,000
-
20.00 NON DSR Exhaust fan of 380mm dia. 900rpm single phase heavy duty.
Nos 300.00 3,000.00 900,000
-
Total SH 05- Light and Fans 6,040,902

SH-06 TELEPHONE SYSTEM

Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
1.00 DSR - 1.53 recessed steel/ PVC conduit as required.
Metre 690.00 33.00 22,770
-

431
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
2.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.
-
-
25mm
DSR -
a
1.21.2
Metre 375.00 65.00 24,375
32mm
DSR -
b
1.21.3
Metre 175.00 32.00 5,600
-
-
Supplying and fixing modular switch/ socket outlet,on the existing modular
3.00 DSR - 1.24 plate & switch box including connections but excluding modular plate etc.
as required. -
-
DSR -
Telephone Outlet (RJ-45)
a
1.24.6
Nos. 78.00 95.00 7,410
-
Laying of PVC insulated armoured 10 Pair with 0.5 mm dia, Tinned copper
Derived
conductor Telephone cables including excavation,supply & fiiling of sand
4.00 DSR REF:
7.2.1
and bricks .
Metre 2,964.00 133.00 394,212
-
Laying of PVC insulated armoured 50 Pair with 0.5 mm dia, Tinned copper
Derived
conductor Telephone cables including excavation,supply & fiiling of sand
5.00 DSR REF:
and bricks.
7.2.2
Metre 50.00 141.00 7,050
-
Laying of PVC insulated armoured 10 Pair with 0.5 mm dia, Tinned copper
Derived
6.00 DSR REF: conductor Telephone cables in exisitng hume pipes.
7.5.1
Metre 50.00 16.00 800
-

432
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply and installation of wall/recessed mounting KRONE connector type
telephone tag block of following sizes in sheet metal enclosure of suitable
dimensions fabricated out of 16 SWG sheet steel with castle key lock,
7.00 Non DSR
hinged gasketed type cover including termination of telephone cables,
making connections, painting of box etc, complete as required.
-
-
a 10 Pair Tel Tag Block
Nos. 30.00 273.00 8,190
b 100 Pair Tel Tag Block
Nos. 1.00 4,086.00 4,086
-
-
Supply of following size anealed tinned copper conductor PVC insulated
and sheathed armoured copper telephone cables with suitable clamps,
8.00 Non DSR saddles on existing cable trays / raceways etc and including making terminal
joints complete as required.
-
-
a 10 Pair
Metre 2,250.00 83.00 186,750
b 50 Pair
Metre 200.00 415.00 83,000
-
Supply , Erecting & Commissioning of Main Distribution Frame (MDF) box
indoor type with wall mounting facility having front door with lock and
9.00 Non DSR suitable for following capacity along with aluminium frame for mounting
krone modules. Complete cabinet fabricated from 18SWG CRCA Sheet with
powder coated in approved manner
-
-
a 200x200pairs
set 1.00 20,929.00 20,929
-
Total SH 06- Telephone System 765,172

SH-07 FIRE ALARM SYSTEM

433
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Wiring in existing conduit : Supplying and drawing following sizes of FR PVC
1.00 DSR - 1.17 insulated copper conductor , single core cable in the existing
surface/recessed Steel /PVC conduit as required.

DSR -
2 x 1.5 sq.mm
a
1.17.2 Metre 12,800.00 36.00 460,800
DSR -
3 x 1.5 sq.mm
b
1.17.3 Metre 304.00 50.00 15,200
-
-
S/F Steel conduit : Supplying and fixing of following sizes of Steel conduits
along with accessories in surface/ recess including painting in case of
2.00 DSR – 1.20 surface conduit,or cutting the wall and making good the same in case of
recessed conduit as required.
-
20mm
DSR –
a
1.20.1 Metre 450.00 121.00 54,450
25mm
DSR –
b
1.20.2
Metre 10,240.00 142.00 1,454,080
32 mm
DSR –
c
1.20.3
Metre 199.00 193.00 38,407
-
Laying of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables including
DerivedDS
3.00 excavation,supply & fiiling of sand and bricks .
R – 7.3.1
Metre 450.00 75.00 33,750
-
Layingof 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng hume pipes.
Derived
4.00
DSR – 7.5.1
Metre 199.00 15.00 2,985
-
Laying of of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables on surface
including supply and fixing of G.I. Spacer, saddles etc.
Derived
5.00
DSR – 7.7.1
Metre 100.00 25.00 2,500

434
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
Laying of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng laid
DerivedDS Concealed/Surface conduits, cables trays.
6.00
R – 7.8.1
Metre 13,000.00 25.00 325,000
-
Supply, Installation, Testing & Commissioning of Analog Addressable type Self
Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting
base, LED, Address Switch, complete with MS Powder coated Junction Box for
7.00 NON -DSR mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends,
cable compression glands, cable tags and Ferruling. (BFC)
Nos 418.00 5,200.00 2,173,600
-
Supply, Installation, Testing & Commissioning of Analog Addressable type Self
Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting
base, LED, Address Switch, complete with MS Powder coated Junction Box for
8.00 NON -DSR mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends,
cable compression glands, cable tags and Ferruling. (AFC)
Nos 450.00 5,200.00 2,340,000
-
Supply, Installation, Testing & Commissioning of Analog addressable Rate of
Rise Cum Fixed temperature detector with standard mounting base, LED,
Address Switch, complete with MS Powder coated Junction Box for mouting
9.00 on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.
Nos 65.00 4,400.00 286,000
-
Supply, Installation, Testing & Commissioning of Response Indicator with
matching screws complete with GI Junction box, Cable lugs at cable end
10.00 and ferruling.

Nos 404.00 118.00 47,672


-
Devices
11.00 -
-

435
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Addressable Dual Action
Manual Pull Station with Adddress Switch and all mounting accessories ,
11.01 complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 28.00 6,700.00 187,600
Supply, Installation, Testing & Commissioning of Fireman's Phone Jackwith all
mounting accessories, complete with MS Powder coated Junction Box for
11.02 mounting on Surface, Cable Lugs at Ends and all required accesories for
mounting at site complete as requried.
Nos 30.00 5,000.00 150,000
Supply, Installation, Testing & Commissioning of Addressable Module for Fire
Phone Jack with Adddress Switch and all mounting accessories, complete
11.03 with MS Powder coated Junction Box for mouting on Surface, Cable lugs at
Ends, cable compression glands, cable tags and Ferruling.
Nos 30.00 5,800.00 174,000
Supply, Installation, Testing & Commissioning of Addressable Relay Module
with Address Switch and all mounting accessories complete as required.
Shall be complete with Pilot Relay for Tripping of Third Party Equipment,
suitable for switching 5A/15A current through the Relay contacts , MS Powder
11.04
coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.

Nos 8.00 5,800.00 46,400


Supply, Installation, Testing & Commissioning of Addressable Control Module
with Address Switch and all mounting accessories, complete with MS Powder
11.05 coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.
Nos 58.00 5,800.00 336,400
Supply, Installation, Testing & Commissioning of Fault Isolator Module ,
complete with MS Powder coated Junction Box for mouting on Surface,
11.06 Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 95.00 5,100.00 484,500
-
Supply, Installation, Testing & Commissioning of Directional Sounders with
20Hz to 20 KHz operating frequency with minimum 8 distinct sound patterns
to indicate Exit doors and direct occupants for safe and fast evacuation ,
11.07
complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 30.00 21,000.00 630,000

436
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Voice
Evacuation Speaker having power taps upto 2W and frequency response of
11.08 400 to 4000Hz for Voice Evacuation.
Nos 97.00 2,300.00 223,100
Supply, Installation, Testing & Commissioning of Wall Mounted Voice
Evacuation Speaker having power taps upto 2W and frequency response of
11.09
400 to 4000Hz for Voice Evacuation.
Nos 29.00 5,400.00 156,600
Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Muli-
Candela Strobe with all required accessories for mounting complete as
11.10 required.
Nos 33.00 6,800.00 224,400
12.00 Control And Annunciation
-
Supply, Installation, Testing & Commissioning of Microprocessor based 10
loop capacity , Networkable Analogue Addressable type Fire Alarm Control
panel.

The FACP shall have minimum 640 character Display with fully functional
QWERTY Keypad. Each loop shall have a maximum loading of 125 detectors
and 125 devices in one loop with 20% spare capacity. Four access levels,
flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts
sealed lead acid batteries sufficient for 24 hours normal working and for 2
hours during an emergency conditions as required. The FACP shall be UL 9th
12.01 Edition Listed. FACP should be with Network Communication Module with
true peer to peer Connectivity.

Failure of Fire Alarm Panel CPU shall not result in failure of operation of
Amplifiers. Hence if the Digital Audio Amplifiers are CPU Rail Mounted,
consider 1 No. CPU dedicated for Digiital Audio Amplifier Bank.

FACP cost to include all necessary cards, modules, enclosure, CPU and
associated acccessories to complete the system design. All components
including enclosures shall be UL Listed.
Nos 1.00 971,500.00 971,500
-

437
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Network Control Annunciator
for Fire Command Station with Digital Voice Command Centre with 2 way
Fire Fighters Communication System.

The DVC shall have an Integrated 8 Channel Digital Audio Command Centre
with a capacity to communicate and transmit pre-recorded and paging
messages through the Digital Audio Amplifiers distributed across various floors
of the building on a Digital Audio Loop with zone control function and other
accessories required to complete the system. The System shall have minimum
of 24 Zone Selection Switched.

The Network Control Annunciater and Digital Voice Command Centre shall
be enclosed in the same enclosure and both shall act as independent nodes
12.02 on the true peer to peer network.

The Networked Annunciater shall have minimum 640 character backlit LCD
display with QWERTY keypad, control interface and "soft" and "hard" keys.

The NCA shall have control and display capabilities for all nodes on the
network.

NCA shall be capable to select any zone to relay voice evacution message
from the fire command station.

Voice Command Center shall have a true Network Communication Module


with true peer to peer Connectivity. 1 1.00 542,690.00 542,690
-
Supply, Installation, Testing & Commissioning Networkable Reapter Panel
with 640 Character Backlit LCD Display and fixed function Keys and Soft Keys.
12.03
Reapter Panel should be on true peer to peer network.
Nos 1.00 230,000.00 230,000
-
Supply, Installation, Testing & Commissioning of Digital Audio Amplifier / Zone
Amplifier capable of processing 1 of 8 audio channels and total of 100W at
12.04 70.7 VRMS output along with necessary enclosures. The DAA shall be fully
monitored for fault and alarm reporting. Power Amplifiers shall not be
permitted. UL Listed.
Nos 2.00 304,600.00 609,200
-

438
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Power Supply Unit - 240VAC
to 24VDC - 6Amps. Power Supply shall be UL Listed with Necessary Battery
12.05
Backup.
Nos 1.00 64,700.00 64,700
-
Cabling
13.00
-
Providing, testing and installing / fixing of approved make 20 mm dia.MS
13.01 Non DSR flexible conduits on ceiling / wall / floor etc. complete with accessories like,
Junction boxes, Collars, Bends etc. metre 467.00 60.00 28,020
-
Total SH 07- Fire Detection & Alarm System 12,293,554

DATA NETWORKING
SH-08
SH-08 A RESIDENTIAL BLOCK

LAN SYSTEM
1.00

Supplying & laying of PVC sheathed flame retardant Untwisted Pair


1.01 (Untwisted Pair (UTP)) Cable of Cat - 6 back bone cable for Data & Voice
outlets. Mtr 2,200.00 53.00 116,600
-
Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6
1.02 RJ-45 information outlet module for Data & Voice.
Each 44.00 550.00 24,200
-
Supplying, installing, testing and commissioning of 24 Port Cat - 6 Untwisted
1.03 Pair (UTP) Patch Panel for Data Networking for back bone cable.
Each 1.00 17,050.00 17,050
-
Supplying, installing, testing and commissioning of 48 Port Cat - 6 Untwisted
1.04 Pair (UTP) Patch Panel for Data Networking for voice
Each 1.00 500.00 500
-
Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6
1.05 Patch Cord of following length. 7ft
Each 50.00 415.00 20,750
-

439
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6
1.06 Patch Cord of following length. 4ft
Each 100.00 350.00 35,000
Supply installation testing and commissioning 2- Port Mosaic Faceplate -
1.07 White Each 21.00 220.00 4,620
1.08 Supply installation testing and commissioning Blank Insert For Faceplate 180.00
Each 21.00 3,780
2.00 Server & Wall mount Rack and cable management
-
Supply installation testing and commissioning of 600 mm x 600 mm 15 U
230 V AC 90 CFM fan 2 , three Hardware packet 1 set ( containing 20 Nos
2.01
each of 3), stationary shelf , Two Cable manager 1U height.
Each 1.00 21,750.00 21,750
Supply installation testing and commissioning 1U Horizontal Cable Manager
2.02 (For Field Cables & Switches)
Each 2.00 885.00 1,770
Supply installation testing and commissioning 6 / 12 Socket Universal Power
2.03 Strip with MCB
Each 1.00 3,000.00 3,000
Supply installation testing and commissioning Extra Hardware packets for
2.04 300.00
Racks Each 1.00 300
Supply installation testing and commissioning Labels for 4-pair Patch Cords
2.05 (70 labels per sheet)
Set 1.00 375.00 375
-
3.00 EDGE SWITCHES -
-
Supply installation testing and commissioning 24 Port 10/100/1000Mbps + 2
ports for optional SFP/ SX Modules supporting 1G, layer 2 switch with
3.01
Stacking cable (Non-blocking switch fabric, IPv6 ready), option for RPS
Each 3.00 88,125.00 264,375
-
Supply installation testing and commissioning Multi-Mode SFP /SX
3.02 transceivers supporting 1G
Each 1.00 21,750.00 21,750
-
Total SH 08 A- RESIDENTIAL BLOCK 535,820

440
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-09 TV System

Supplying and fixing following modular switch/ socket on the existing


1.00 DSR-1.24 modular plate & switch box including connections but excluding modular
plate etc. as required.
TV antenna socket outlet
a DSR-1.24.7
Each 378.00 93.00 35,154
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
2.00 DSR - 1.53 recessed steel/ PVC conduit as required.
Metre 7,560.00 33.00 249,480
-
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
3.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.
-
DSR - 25mm
a
1.21.2 Metre 6,048.00 65.00 393,120
DSR - 32mm
b
1.21.3 Metre 200.00 32.00 6,400
-
Total SH 09- TV System 684,154

441
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY OF COST (RESIDENTIAL BLOCK 3 & 4)

SUBSEAD OF WORK
SUBHE AD ESTIMATED
NO AMOUNT IN INR

RESIDENTIAL BLOCK 3 & 4


A.

SH-01 POINT WIRING AND ACCESSORIES: 7,561,842

SH-02 MV PANELS & DISTRIBUTION BOARDS 7,776,764

SH-03 EARTHING SYSTEM 819,712

SH-04 LIGHTNING PROTECTION SYSTEM 322,708

SH-05 LIGHT FIXTURES AND FANS: 7,156,843

SH-06 TELEPHONE SYSTEM 418,910

SH-07 FIRE ALARM SYSTEM 12,384,350

SH-08 DATA NETWORKING 618,145

SH-09 TV System 510,233


SUB TOTAL (A)
37,569,507

LESS 5% FOR UPRNN WORKING (1,878,475)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 35,691,032

442
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DETAILED COST ESTIMATE FOR ELECTRICAL WORKS : RESIDENTIAL BLOCK 3 & 4

SH-01 POINT WIRING AND ACCESSORIES:

Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable in surface /
1.00 DSR - 1.3 recessed steel conduit, with modular switch, modular plate, suitable GI box
and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor
single core cable etc as required.

Group A(Hostel, Residential)


a DSR - 1.3.1
Point 2,553.00 677.00 1,728,381
-
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed steel conduit, 2 way
2.00 DSR - 1.4 modular switch, modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as
required.
Point 55.00 1,069.00 58,795
-
Wiring for circuit/ submain wiring along with earth wire with the following sizes
3.00 DSR -1.7 of FRLS PVC insulated copper conductor, single core cable in surface/
recessed steel conduit as required
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b DSR - 1.7.2
Metre 200.00
200.00 40,000
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c DSR - 1.7.3
Metre 231.00
120.00 27,720
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d DSR - 1.7.4
Metre 175.00 315.00 55,125
-
Wiring for light/power plug with 2X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
4.00 DSR – 1.12 along with 1 no. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required.(RawPower)
Metre 15,000.00 162.00 2,430,000
-

443
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Wiring for light/power plug with 4X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
5.00 DSR – 1.13 along with 2 nos. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required.(RawPower)
Metre 3,995.00 275.00 1,098,625
-
Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes
of FRLS PVC insulated, copper conductor,single core cable in
6.00 DSR – 1.14
surface/recessed medium class PVC conduit as required.
-
-
DSR – 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
a
1.14.1 Metre 4,245.00 106.00 449,970
DSR – 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
b
1.14.2 Metre 375.00 131.00 49,125
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c DSR-1.14.3
Metre 90.00 162.00 14,580
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d DSR-1.14.4
Metre 180.00 221.00 39,780
-
Supplying and drawing following sizes of FRLS PVC insulated copper
7.00 DSR-1.17 conductor, single core cable in the existing surface/ recessed steel/ PVC
conduit as required. -
-
1 x 1.5 sq. mm
a DSR-1.17.1
Metre 90.00 22.00 1,980
2x 1.5 sq. mm
b DSR-1.17.2
Metre 90.00 36.00 3,240
3x 1.5sq. mm
c DSR-1.17.3
Metre 90.00 50.00 4,500
4x 1.5 sq. mm
d DSR-1.17.4
Metre 80.00 63.00 5,040
DSR- 2 x 2.5 sq. mm
k
1.17.11 Metre 28.00 53.00 1,484
DSR- 2 x 4 sq. mm
t
1.17.20 Metre 56.00 77.00 4,312
DSR- 2 x 4 sq. mm
u
1.17.21 Metre 31.00 109.00 3,379
-

444
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing of following sizes of steel conduit along with accessories
in surface/recess including painting in case of surface conduit, or cutting the
8.00 DSR-1.20
wall and making good the same in case of recessed conduit as required.
-
20 mm
a DSR-1.20.1
Metre 31.00 121.00 3,751
25 mm
b DSR-1.20.2
Metre 112.00 142.00 15,904
32 mm
c DSR-1.20.3
Metre 50.00 193.00 9,650
40 mm
d DSR-1.20.4
Metre 35.00 287.00 10,045
50 mm
e DSR-1.20.5
Metre 23.00 387.00 8,901
Supplying and fixing of following sizes of medium class PVC conduit along
with accessories in surface/recess including cutting the wall and making
9.00 DSR-1.21
good the same in case of recessed conduit as required.
-
20 mm
a DSR-1.21.1
Metre 112.00 53.00 5,936
25 mm
b DSR-1.21.2
Metre 200.00 65.00 13,000
32 mm
c DSR-1.21.3
Metre 150.00 85.00 12,750
40 mm
d DSR-1.21.4
Metre 120.00 110.00 13,200
50 mm
e DSR-1.21.5
Metre 60.00 144.00 8,640
-
Supplying and fixing metal box of following sizes (nominal size) on surface or
in recess with suitable size of phenolic laminated sheet cover in front
10.00 DSR-1.22
including painting etc as required.
-
75 mm X 75 mm X 60 mm deep
a DSR-1.22.1
Each 75.00 89.00 6,675
150 mm X 75 mm X 60 mm deep
c DSR-1.22.3
Each 31.00 111.00 3,441
150 mm X150 mm X 60 mm deep
d DSR-1.22.4
Each 75.00 160.00 12,000
-

445
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing following modular switch/ socket on the existing
11.00 DSR-1.24 modular plate & switch box including connections but excluding modular
plate etc. as required. -
-
5/6 amps switch
a DSR-1.24.1
Each 536.00 81.00 43,416
2 way 5/6 amps switch
b DSR-1.24.2
Each 15.00 96.00 1,440
15/16 amp switch
c DSR-1.24.3
Each 615.00 111.00 68,265
3 pin 5/6 amp socket outlet
d DSR-1.24.4
Each 1,001.00 79.00 79,079
6 pin 15/16 amp socket outlet
e DSR-1.24.5
Each 615.00 150.00 92,250
Telephone socket outlet
f DSR-1.24.6
Each 20.00 95.00 1,900
TV antenna socket outlet
g DSR-1.24.7
Each 225.00 94.00 21,150
Bell push
h DSR-1.24.8
Each 96.00 111.00 10,656
-
S/F Modular Type Blanking Plate : Supplying and fixing modular blanking
12.00 DSR - 1.26 plate ,on the existing modular plate & switch box excluding modular plate
etc. as required. Each 55.00 23.00 1,265
-
S/F GI Box along with modular plate: Supplying and fixing following size
13.00 DSR – 1.27 /modules, GI box along with modular base & cover plate for modular
switches in recess etc as required.
-
-
DSR – 1 or 2 Module(75mmx75mm)
a Each 166.00
1.27.1 1,500.00 249,000
3 Module (100mmX75mm)
b DSR-1.27.2
Each 1,523.00 175.00 266,525
4 Module (125mmX75mm)
c DSR-1.27.3
Each 22.00 195.00 4,290
-

446
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply & fixing following modular base and cover plate for modular
14.00 DSR - 1.28 switches in recess etc as required.
-
-
DSR - 1 or 2 Module
a
1.28.1 Each 1,500.00 79.00 118,500
DSR - 3 Module
b
1.28.2 Each 1,523.00 88.00 134,024
DSR - 4 Module
c
1.28.3 Each 22.00 97.00 2,134
-
Supplying and fixing 3 pin, 5 amp ceiling rose ,on the existing junction box
15.00 DSR - 1.33 including connection etc. as required.
Each 310.00 43.00 13,330
-
Supplying and fixing brass batten/angle holder including connection etc. as
16.00 DSR - 1.34 required.
Each 35.00 74.00 2,590
-
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
17.00 DSR - 1.36 including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.
Each 125.00 163.00 20,375
-
Supplying and fixing stiff pendent with 600 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
18.00 DSR - 1.37 including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.
Each 55.00 163.00 8,965
-
Supplying and fixing call bell/ buzzer suitable for single phase,230 Volts,
19.00 DSR - 1.38 complete as reqired.
Each 98.00 61.00 5,978
-
Providing and fixing 16/0.20mm (0.50sqmm) twin flat flexible,FRLS PVC
20.00 DSR - 1.39 insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or
side of the table/ door etc. as required.
Each 55.00 21.00 1,155
-

447
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC
21.00 DSR - 1.40 . insulated, PVC sheathed copper cable direct on the wall with PVC clips etc.
as required. Each 55.00 19.00 1,045
-
Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug
DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
22.00
minus1.20. insulated, copper conductor single core cable for loop earthing as
1)
required.(UPS Power)
Metre 25.00 107.00 2,675
-
Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug
DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
23.00
minus1.20. insulated, copper conductor single core cable for loop earthing as
1)
required.(RawPower)
Metre 110.00 107.00 11,770
-
Wiring for the following light points with 1.5 sq.mm PVC insulated
copper conductor 1100 volts grade stranded flexible FRLS wires of
approved make in concealed or surface mounted 25 mm dia medium
24.00 DRDSR class PVC conduit controlled by SPMCB provided in the DB and earthing of
fixtures with 1.5 sq.mm PVC insulated copper conductor stranded flexible
FRLS wire.(Cost of MCB not to be included here)
-
-
a One point controlled by one MCB. Points 228.00
48.00 10,944
b Two points controlled by one MCB. Points 456.00
15.00 6,840
c Three points controlled by one MCB. Points 684.00
27.00 18,468
d Four points controlled by one MCB. Points 912.00
15.00 13,680
e Five points controlled by one MCB Points 1,140.00
54.00 61,560
f Six points controlled by one MCB. Points 1,368.00
20.00 27,360
g Seven points controlled by one MCB. Points 1,596.00
7.00 11,172
h Eight points controlled by one MCB. Points 1,824.00
5.00 9,120
I Nine points controlled by one MCB. Points 2,052.00
36.00 73,872
j Ten points controlled by one MCB. Points 2,280.00
4.00 9,120

448
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
Supplying and fixing 250x150x75 mm deep, 1.6 mm thick G I Junction box
25.00 NON DSR with coverplate complete as per site requirement.
Nos 36.00 500.00 18,000

TOTAL FOR SH-01 - POINT WIRING AND ACCESSORIES: 7,561,842

SH-02 MV PANELS & DISTRIBUTION BOARDS

Providing and fixing following rating and breaking capacity MCCB in existing
1.00 DSR - 2.2 cubicle panel board including drilling holes in cubicle panel, making
connections, etc. as required.

200 Amp, 25 KA , TP MCCB


a DSR - 2.2.5
Each 1.00 8,814.00 8,814
400 Amp, 35 KA , TP MCCB
b DSR - 2.2.9
Each 1.00 17,372.00 17,372
-
2.00 DSR - 2.3 S/F prewired SP MCB DB : Supplying and fixing following way single pole and
neutral,sheet steel MCB distribution board 240 volt,s on surface/recess,
complete with tinned copper bus bar , neutral bus bar , earth bar , din bar ,
interconnections , power painted including earthing etc. as required .(But
without MCB/RCCB/Isolator ).
-
a DSR - 2.3.5 2+4 way /6 Way ,Double Door Each 923.00

2.00 1,846
b DSR - 2.3.6 2+6 Way / 8 Way,Double Door Each 1,041.00

1.00 1,041
c DSR - 2.3.7 2+8 Way / 10 way,Double Door Each 1,132.00

3.00 3,396
-

449
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
S/F prewired TP MCB DB : Supplying and fixing following way prewired TP&N
MCB distribution board of steel sheet for 415 volts on surface/recess,
complete with loose wire box, terminal connectors for all incoming and
3.00 DSR - 2.8 outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper
conductor up to terminal blocks , tinned copper bus bar , neutral link , earth
bar , din bar , detachable gland plate , interconnections , power painted
including earthing etc. as required .(But without MCB/RCCB/Isolator ).
-
-
4 way (4 + 12 ),Double Door
a DSR – 2.8.5
Each 1.00 7,357.00 7,357
6 way (4 + 18 ),Double Door
b DSR – 2.8.6
Each 25.00 9,496.00 237,400
8 way (4 + 24 ),Double Door
c DSR – 2.8.7
Each 110.00 10,405.00 1,144,550
12 way (4 + 36 ), Double Door (LPDB)
d DSR – 2.8.8
Each 4.00 12,782.00 51,128
-
S/F 'C' Curve , SP MCB : Supplying and fixing 5 amps to 32 amps, rating,
240/415 volts, 'C' Curve , miniature circuit breaker suitable for inductive load
4.00 DSR - 2.10 of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.
-
-
DSR -
Single Pole
a
2.10.1 Each 3,250.00 169.00 549,250
DSR -
Single Pole and Neutral
b
2.10.2 Each 115.00 441.00 50,715
-
S/F SP MCB blanking plate : Supplying and fixing single pole blanking plate in
5.00 DSR - 2.11 the existing MCB DB complete etc.as required.
Each 40.00 7.00 280
-
S/F DP MCB isolator : Supplying and fixing following rating, double pole , 240
6.00 DSR - 2.12 volts, isolator in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
-
-

450
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
DSR - 40 amps
a
2.12.1 Each 4.00 218.00 872
-
S/F FP MCB isolator : Supplying and fixing of following rating, four pole , 415
volts, isolator in the existing MCB DB complete with connections, testing and
7.00 DSR - 2.13
commissioning etc. as required.
-
DSR -
40 amps
a
2.13.1 Each 25.00 659.00 16,475
DSR -
63 amps
b
2.13.2 Each 136.00 670.00 91,120
-
S/F SPN RCCB :Supplying and fixing following rating, double pole, (single
phase and neutral), 240 volts, residual current circuit breaker (RCCB), having
8.00 DSR - 2.14 a sensitivity current upto 300 milliamperes in the existing MCB DB complete
with connections, testing and commissioning etc. as required.
-
-
DSR -
25 amps
a
2.14.1 1,645.00
Each 92.00 151,340
DSR -
40 amps
b
2.14.2 Each 376.00 1,714.00 644,464
Supplying and fixing following rating, four pole, (three phase and neutral),
415 volts, residual current circuit breaker (RCCB), having a sensitivity current
9.00 DSR - 2.15 upto 300 milliamperes in the existing MCB DB complete with connections,
testing and commissioning etc. as required.
-
DSR -
40 amps
a
2.15.2 Each 1,714.00
1.00 1,714
DSR -
63 amps
b
2.15.3 Each 2,237.00
1.00 2,237
-
-

451
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with
16/25/32amps 240 volts "C" curve DP MCB complete with connections, testing
10.00 DSR - 2.16
and commissioning etc. as required.
Each 2.00 617.00 1,234
-
Supplying and fixing TP sheet steel enclosure on surface/ recess along with
16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing
11.00 DSR - 2.17
and commissioning etc. as required.
Each 2.00 868.00 1,736
-
S/F 20 A SPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 240
Volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed
plug top along with 20 Amps, C-Curve, SP MCB, in sheet steel enclosure, on
12.00 DSR - 2.18
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 4.00 954.00 3,816
-
-
S/F 20 A TPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 20 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
13.00 DSR - 2.19 surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.

Each 2.00 1,967.00 3,934


-
S/F 30 A TPN MCB industrial socket outlet : Supplying and fixing 30 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 30 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
14.00 DSR - 2.20
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 1.00 2,473.00 2,473
-

452
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying,Installation, testing and commissioning of cubical type LT panel
suitable for 415V, 3 Phase,4 wire 50 Hz AC supply system fabricated in
compartmentalized design from CRCA sheet steel of 2mm thick for frame
work and covers, 3mm thick for gland plates i/c cleaning & finishing
completed 9 tank process of powder coating in approved shade,having
extensible type TPN Aluminium alloy bus bars of high conductivity,DMC/SMC
bus bar supports,with short circuit withstand capacity for 1 sec, bottom base
channel of MS section not less that 100 mm x 50mm x 5mm thick, fabrication
15.00 shall be done transportable sections,entire panel shall have a common
copper earth bar of size 25mmx5mm at the rear with 2 no's earth stud,solid
connections from main bus bar to switchgears with required size of
alunimium bus bars and control wiring PVC insulated copper conductor S/C
cable alleys,cable gland plates in two half,i/c providing following switch
gears: (with all necessary hardware, accessories as required for complete
installation as per specifications and single line digram).
-
-
Refer CPWD general specification for Electrical works Part IV Sub station
-
Note: 1.Provision for both Bottom & Top cable entry shall be provided in All
Panels .
-
-
All panles shall be indoor type unless otherwise mentioned. Only feeder pillers
shall be outdoor type.
-
-
MV PANELS
-
General Notes:
-
-
A. ACB: -
-
LSIG (Microprocessor Based) releases shall be used for incoming feeders such
i as Transformers and DG Sets & LSI releases for outgoing breakers. All ACB
shall have Icu = Ics = Icw for 1 Second.
-
-

453
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
All 4 Pole ACB shall have fully Rated neutral equal to rating of the breaker &
ii shall be protected against overload & short-circuit .
-
-
Ready-to-close contact shall exist for indicating that all safety parameters
iii are checked & enabling closure of breaker, ensuring at-most safety for the
user
-
-
A door interlock shall be provided so that it shall not be possible to open the
iv door until the air circuit breaker moving part is in the disconnected position.
-
-
B. MCCB:
-
-
i. All MCCBs shall be suitable for 3 Phase 415 Volts AC 50 HZ supply
-
-
All MCCBs shall have rated service breaking capacity (Ics) equal to the
ii. ultimate breaking capacity (Icu) at defined operational voltage.
-
-
All MCCBs shall clearly indicate the suitability for isolation in the name plate
iii. identified by the symbol
-
-
All MCCBs shall offer class –II front face i.e. main current path of the circuit
iv. breaker should be isolated from auxiliary section
-
-
v. All Incomer MCCBs shall be provided with earth fault protection
-
-
MCCBs of above250A Microprocessor Based and upto 250A thermal
vi. Magnetic releases.
-
-

454
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
This BOQ to be read in conjunction with technical specifications and Single
Line Diagram (attached for reference). If any discrepancy occurs that should
vii. be brought to the notice of Client/Consultant before quoting the price
otherwise stringent condition will be deemed to have been considered.
-
-
All ACBs to be provided with ON/OFF/Trip lamps, 3 NO + 3NC Auxiliary
viii. contacts other than used in control circuit.
-
-
All Transformer and DG incoming ACBs shall be provided with Microprocessor
ix. based releases & ON/OFF/Trip / Spring charged/ready to close indicating
lamps. -
-
All MCCBs shall be provided with rotary operating handle and ON/OFF lamps
x. backed by 2Amp control MCB.
-
-
All meters shall be digital type (unless otherwise specified)
xi. -
-
Multi-function meter to be provided as required to cover all the parameters
xii. as mentioned.
-
-
xiii. All current/voltage transformer shall be cast resin type.
-
-
All indicating lamps shall be LED type.
xiv. -
-
Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus
bar is after considering all derating factors. (Bus bar sizing calculation to be
xv. submitted for approval.)
-
-
All internal control wiring shall be heat resistant type.
xvi. -
-

455
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
xvii. All incoming breakers in Main LT panel shall be electrically interlocked.
-
-
All TP feeders shall be provided with Isolable neutral link.
xviii.
-
-
Bus bar chamber shall be provided at top only. Incoming and outgoing
xix. cable entry shall be from top/bottom as required.
-
-
Bus couplers in Main MV Panel shall be Microprocessor based with all
xx. releases. -
-
Bus couplers shall be provided with ON & OFF indicating lights but without
xxi. releases.

-
-
All feeders shall be provided with door interlocked with door defeat, pad
xxii. lock facility.
-
-
Live parts shall not be accessible after opening the door, Transparent acrylic
xxiii. sheet to be provided to cover the same.

-
-
Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto
xxiv. terminal block.
-
-
xxv. 20% spare control terminal to be provided.
-
-
All MCCBs shall be provided with variable O/L & S/C releases. Incoming
xxvi. MCCB shall be provided with E/F releases also
-
-
xxvii. All incoming/outgoing cables shall be terminated on links/terminals.
-
-

456
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
xxviii. All Panels shall have 100 % Neutral Bus Bar Rating.
-
-
Degree of protection for following type of distribution panel enclosure shall
xxix. be as per IS: 13947-1993.
-
-
IP 43 for indoor panels.
-
IP 55 for outdoor panels.
-
-
Painting/lettering on Breakers and distribution boards, the location they
xxx. serve, providing on each panel its circuit diagram.
-
-
-
15.01 RESIDENTIAL BLOCK PANELS
-
-
-
15.01.1 Non DSR MAIN LT PANEL (RESIDENTIAL BLOCK 3 & 4)
-
Incomer
-
-
800A 4P MDO ACB,50 KA(microprocessor based )
-
-
Metering & Indication:
-
Each Shall have
-
Multifunction Digital meter (consisting of Voltage, Amps, kWh, kW, P.F.
parameter) with RS 485 Port.
-
-
Breaker ON / OFF / TRIP indicating lights with control MCB’s.
-
Set of RYB phase indicating lamps with 2A control MCBs.
-
-

457
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Busbar
-
1000A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).
-
Outgoings:
-
-
Set of RYB phase indicating lamps with 2A control MCBs on each outgoing
to be provided.
-
Each Outgoing shall be provided with 3-phase digital type energy meters
with Communication Port. -
-
Ten (10) Nos. 63 A 4P MCB (10KA)
-
Three (3) Nos. 630 A TP MCCB (25KA)
-
Two (2) Nos. 125 A TP MCCB (25KA)

Set 1.00 626,700.00 626,700


-
15.01.2 Non DSR MDB (RESIDENTIAL BLOCK -Typical)
-
-
Incomer -
-
100 A TP MCCB,25 KA
-
Metering & Indication:
-
Each Shall have
-
-
Breaker ON / OFF / TRIP indicating lights with control MCB’s.
-
Set of RYB phase indicating lamps with 2A control MCBs.
-

-
Busbar
-

458
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
160 A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating).
-
Outgoings:
-
-
Two Nos 3 Phase Dual & Digital Type Energy Meters
-
Four (4) Nos. 63 A 4P MCB (10KA) 121,000.00
Set 32.00 3,872,000
-
-
15.01.3 Non DSR MDB BASEMENT(RESXIDENTIAL BLOCK 3 & 4)
-
Incomer
-
-
125A TP MCCB,25 KA
-
Metering & Indication:
-
Each Shall have
-
-
Breaker ON / OFF / TRIP indicating lights with control MCB’s.
-
Set of RYB phase indicating lamps with 2A control MCBs.
-
-
Busbar
-
200A, TPN aluminium, colour coded sleeved bus bars suitable for 415V, 50Hz
(after derating). -
Outgoings:
-
-
Set of RYB phase indicating lamps with 2A control MCBs on each outgoing
to be provided. -
One (1) Nos. 100 A TP MCCB (25KA)
-
Ten (10) Nos. 63 A 4P MCB (10KA) 114,900.00
Set 1.00 114,900
-
-
15.01.4 Non DSR Lift Panel (RESXIDENTIAL BLOCK 3 & 4)
-
-

459
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Incoming (1 No.):
-
-
100Amp TP+N MCCB, 25kA
-
-
Metering & Indication:
-
(0-500) volts digital voltmeter with selector switch protected by 2A control
MCB's -
-
(0-100A) Digital ammeter with Selector Switch and 100/5 amps Cl-1, 5VA CT's
-
-
Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.
-
-
Bus Bars: -
160A, TPN aluminium , colour coded Sleeved bus bars suitable for 415V, 50Hz.
(after deration) -
-
Outgoings
-
Phase indicating lamps with 2A Control MCB shall be provided on each
outgoing. -
-
1 Nos. 40A 4P MCB (10 KA) -
3 Nos. 40A 4P RCBO (30 mA,10 KA)
Set 2.00 84,300.00 168,600
-

TOTAL FOR SH-2 - MV PANELS & DISTRIBUTION BOARDS:


7,776,764

SH-03 EARTHING SYSTEM

G.I. earth plate electrode : Earthing with GI earth plate 600mm X 600mm X 6
mm thick including accessories and providing masonary enclosure with
1.00 DSR - 5.4 cover plate having locking arrangement and watering pipe of 2.7 metre
long etc. with charcoal/coke and salt as required.
Set 10.00 4,490.00 44,900

460
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
Copper earth plate electrode : Earthing with Copper earth plate 600mm X
600mm X 3 mm thick including accessories and providing masonary
2.00 DSR - 5.6 enclosure with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/coke and salt as required.
Set 6.00 9,292.00 55,752
-
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground
as strip earth electrode, including connection/ terminating with G.I. nut, bolt,
3.00 DSR - 5.8 spring, washer etc. as required. (Jointing shall be done by overlapping and
with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Metre 45.00 753.00 33,885
-
Supplying and laying 25mm x 5 mm GI strip at 0.50 m below ground as strip
earth electrocde, including connection/terminating with G.I. nut, bolt, spring,
4.00 DSR - 5.9 washer etc. as required. (Jointing shall be done by overlapping and with 2
sets of G.I nut bolt & spring washer sapced at 50mm).
Metre 450.00 109.00 49,050
-
-
Providing & Fixing 25mm x 5 mm Copper strip in 40 mm dia G.I. Pipe from
5.00 DSR - 5.10 earth electrode including connection with brass nut, bolt, spring, washer
excavation and re-filling etc. as required.
Metre 45.00 1,082.00 48,690
-
-
Providing & Fixing 25mm x 5 mm G.I. Strip in 40 mm dia G.I. pipe from earth
6.00 DSR - 5.11 electrode including connection with G.I. nut, bolt, spring, washer excavation
and re-filling etc. as required.
Metre 45.00 421.00 18,945
-
-
Providing and laying earth connection from earth electrode with 6 SWG dia
7.00 DSR - 5.12 G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection
with G.I. thimble excavation and re-filling as required.
Metre 45.00 151.00 6,795
-
Providing and fixing 6 SWG dia GI wire on surface or in recess for
8.00 DSR – 5.16 connections etc. as required.
Metre 25.00 35.00 875
-

461
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for
9.00 DSR - 5.20. connections etc. as required.
Metre 105.00 1,599.00 167,895
-
Supplying and fixing earth bus of 50mmx6mm GI strip on surface for
10.00 Non DSR connections etc as required. Metre 105.00 350.00 36,750
60 mm x 10 ( or 50 x 12) mm x 1.2 mtrs length copper earth bus bar with
a MR
insulators, making suitable size holes etc as required Sets 50.00 2,500.00 125,000
60 mm x 10 ( or 50 x 12) mm x 1.2 mtrs length GI earth bus bar with insulators,
b MR
making suitable size holes etc as required Sets 50.00 2,500.00 125,000
c MR Providing and fixing OF 50 mm x 10 mm thick copper tape.
RM 50.00 1,950.00 97,500
d MR Providing and fixing 8 SWG GI wire.
RM 225.00 18.00 4,050
Providing and laying GI tape 32 mm X 6 mm from earth electrode directly in
11.00 DR DSR ground as required.
Metre 25.00 185.00 4,625
-
TOTAL FOR SH-3 - EARTHING SYSTEM
819,712

LIGHTNING PROTECTION SYSTEM


SH-04
Lightning Arrestor:Supply, installation, testing and commissioning of External
Lightning wide area protection system based on Eaarly Streamer Emission
(ESE) technology. Device shall emit electromagnetic impulse in the form of a
streamer into the air microseconds earlier than naturally formed streamers.
1.00 Non DSR Device confirmg to NFC 17-102 and UNE 21186 Standards. Appropriate non
penetrating mounting arrangement. The device shall be mounted at
suitable clear to the highest point on the roof top. (Model selected shall give
coverage of 79 M radius @ min 5M height from terrace )
Each 1.00 154,800.00 154,800
Down conductor:Supply, installation, testing and commissioning of 70 Sqmm
2.00 Non DSR twisted 19-Strand, bare Cu cable on surface/wall / as per site requirement
and complete in all respect. Metre 105.00 700.00 73,500
Lightning Counter :Supply and installation of counting the number of
3.00 Non DSR lightning strikes without any power supply. Each 1.00 22,500.00 22,500

462
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Maintenance Free Earthing:Supply, installation, testing and commissioning of
maintenance free electrolytic earthing system with 10 feet's rod, 2 inches dia,
2mm thick that does not require manual addition of water. The system should
be stable operation for at least 30 years. The electrode shall be electrolytic
grade copper rod pre-filled with hygroscopic powder and provided with
4.00 Non DSR suitable breathing and leaching ports at the ends. The electrode shall be
surrounded by suitable powdered form of backfill so as to provide maximum
contact between the electrode and the backfill. The earthing pit shall be
provided with suitable sturdy test well for observation. (The installation
procedures should be followed as instructed by the Earth Electrode Supplier).
Set 3.00 12,500.00 37,500
5.00 Non DSR Test Link :Supply and installation of test link in weather proof IP 65 BOX.
Each 3.00 2,500.00 7,500
Supply, installation, testing and commisioning of 2 x 25W LED Aviation
abstruction light medium bay type 62, complete with lamp, lamp holder,
Condenser necessary connecting wire, 1 X 25 AV with all necessary
6.00 Non DSR
hardware, accessories as required for complete installation. Rate shall
include the cost of necessary steel structures , fixing arrangements in this item.
Refer drawing. Each 1.00 13,908.00 13,908
Providing and fixing M.S.. tape 20 mm X 3 mm thick on parapet or surface of
7.00 Non DSR wall for lightning conductor complete as required .
metre 250.00 52.00 13,000
TOTAL FOR SH-04 - LIGHTNING PROTECTION SYSTEM 322,708

SH-05 LIGHT FIXTURES AND FANS:

S/F Modular Type Electronic Fan Regulator : Supplying and fixing stepped
type electronic fan regulator on the existing modular plate & switch box
1.00 DSR - 1.25
including connections but excluding modular plate etc. as required.
Nos 418.00 284.00 118,712
-
ITC fluoresent fitting directly on surface : Installation ,testing and
commissioning of pre-wired .fluorescent fitting /compact fluorescent fitting of
all types ,complete with all accessories and tube etc.directly on ceiling/wall
2.00 DSR - 1.41
,including connection with 1.5 sq.mm FRLS PVC insulated ,copper conductor
,single core cable and earthing etc.as required.
Nos 1,325.00 91.00 120,575
-

463
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ITC fluoresent fitting on false ceiling : Installation ,testing and commissioning
of pre-wired .fluorescent fitting /compact fluorescent fitting of all types
DRDSR - ,complete with all accessories and tube etc.directly on ceiling/wall ,including
3.00
1.41 connection with 1.5 sq.mm FR PVC insulated ,copper conductor ,single core
cable and earthing etc.as required.
Nos 1,000.00 149.00 149,000
-
ITC Ceiling Fan : Installation ,testing and commissioning of ceiling fan
including wiring the down rods of standard length (upto 30 cm) with 1.5
4.00 DSR - 1.44
sq.mm FR PVC insulated ,copper conductor ,single core cable etc.as
required. Nos 358.00 95.00 34,010
-
Installation, testing and commissioning of ceiling fan, including wiring the
down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated,
5.00 DSR - 1.45 copper conductor, single core cable, including providing and fixing
phenolic laminated sheet cover on the fan box etc. as required.
Nos 25.00 122.00 3,050
-
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia,
heavy gauge including painting etc. as required. (Note : More than 5 cm
6.00 DSR - 1.47 length shall be rounded to the nearest 10 cm and 5 cm or less shall be
ignored)
Nos 25.00 23.00 575
-
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm
dia, heavy gauge including painting etc. as required. (Note : More than 5
7.00 DSR - 1.48
cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be
ignored) Nos 4.00 27.00 108
-
8.00 DSR-1.49 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Nos 856.00 26.00 22,256
-
Installation of exhaust fan in the existing opening, including making good the
9.00 DSR -1.50 damage, connection, testing, commissioning etc. as required.
-
-
Upto 450 mm sweep
DSR -
a
1.50.1
Nos 310.00 204.00 63,240
-

464
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of
10.00 DSR -1.51 all sizes.
Nos 310.00 90.00 27,900
-
Supply of Wall Bracket Light aesthetic wall/ceiling mounted luminaire
suitable for 1 x TCH 14W , with low loss electronic ballast, 14W TCH lamp
11.00 NON DSR complete with all accessories etc as required. Philips make (Vector 14W TCH
207) or Bajaj Make - BTIP 114 ACR.
Nos 991.00 461.00 456,851
-
Supply of 1 x 18 W indoor decorative surface mounted/hanging LED light
fixtures suitable for 1 no. of 18W CFL lamps prewired complete with all
12.00 NON DSR
accessories required as per Bajaj Make BJDS 118 C WEB LX/18 W.
Nos 1,226.00 2,800.00 3,432,800
-
Supply of 1 x 28 W indoor decorative surface mounted/hanging FTL light
fixtures suitable for 1 no. of 28 W T5 lamp prewired complete with all
13.00 NON DSR
accessories required as per Philips Make Line Light GGx310 1 x 28 W TL5 EB O-
SAT. Nos 194.00 1,900.00 368,600
-
Supply of 2 x 28 W indoor decorative surface mounted/hanging FTL light
fixtures suitable for 2 nos. of 28 W T5 lamp prewired complete with all
14.00 NON DSR
accessories required as per Philips Make Line Light GGx620 2 x 28 W TL5 EBP
MI. Nos 76.00 2,350.00 178,600
-
Supply of Bulk Head Light fixture with lamp complete with all accessories etc
15.00 NON DSR as required. Insta Power Bulkhead
Nos 10.00 1,800.00 18,000
-
Supply of 36 W indoor decorative False Ceiling Mounted light fixtures
suitable for 2 no of 36 W TL-D lamp prewired complete with all accessories
16.00 NON DSR required as per Philips Aura TBS 088 2 x TL-D36 W EBE M2.
Nos 24.00 3,300.00 79,200
-
Supply of Mirror Light aesthetic wall/ceiling mounted luminaire suitable for 1
x TCH 14W , with low loss electronic ballast, 14W TCH lamp complete with all
17.00 NON DSR accessories etc as required. Philips make (Vector 14W TCH 207) or Bajaj
Make - BTIP 114 ACR.
Nos 150.00 461.00 69,150
-

465
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Ceiling Fan : Supplying of capacitor type1200 mm sweep ceiling fan
complete with blades, shakle etc. with high breeze, high speed for operation
18.00 NON DSR on 230V, 50 Cy. Single phase A.C. supply confirming to IS 374-1979 and with
double ball bearing system The fan shall be green rated as per BEE norms.
Nos 523.00 1,593.00 833,139
Ceiling Fan : Supplying of capacitor type900 mm sweep ceiling fan complete
with blades, shakle etc. with high breeze, high speed for operation on 230V,
19.00 NON DSR 50 Cy. Single phase A.C. supply confirming to IS 374-1979 and with double
ball bearing system The fan shall be green rated as per BEE norms.
Nos 41.00 1,593.00 65,313
Supply and fixing of metal fan hook box of 10 mm M.S. round bar , bounded
to to RCC bar up to 50 mm length each side & pierced through a 16 SWG
20.00 NON DSR thick MS bowl 100 mm dia , depth up to 75 mm , complete erected in
position . With one coat of red oxide paint and 2 coats of synthetic paint .
Nos 564.00 301.00 169,764
Exhaust fan of 450mm dia. 900rpm single phase heavy duty.
21.00 NON DSR
Nos 4.00 4,000.00 16,000
Exhaust fan of 380mm dia. 900rpm single phase heavy duty.
22.00 NON DSR
Nos 310.00 3,000.00 930,000

Total SH 05- Light and Fans 7,156,843

SH-06 TELEPHONE SYSTEM


Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
1.00 DSR - 1.53 recessed steel/ PVC conduit as required.
Metre 800.00 33.00 26,400
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
2.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.
-
25mm
DSR -
a
1.21.2 Metre 440.00 65.00 28,600
32mm
DSR -
b
1.21.3 Metre 205.00 32.00 6,560

466
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing modular switch/ socket outlet,on the existing modular
3.00 DSR - 1.24 plate & switch box including connections but excluding modular plate etc.
as required.
-
DSR - Telephone Outlet (RJ-45)
a
1.24.6 Nos. 25.00 95.00 2,375
Laying of PVC insulated armoured 10 Pair with 0.5 mm dia, Tinned copper
Derived
conductor Telephone cables including excavation,supply & fiiling of sand
4.00 DSR REF:
and bricks .
7.2.1
Metre 958.00 133.00 127,414
Laying of PVC insulated armoured 50 Pair with 0.5 mm dia, Tinned copper
Derived conductor Telephone cables including excavation,supply & fiiling of sand
5.00 DSR REF:
and bricks.
7.2.2
Metre 125.00 141.00 17,625
Laying of PVC insulated armoured 10 Pair with 0.5 mm dia, Tinned copper
Derived
conductor Telephone cables in exisitng hume pipes.
6.00 DSR REF:
7.5.1
Metre 125.00 16.00 2,000
Supply and installation of wall/recessed mounting KRONE connector type
telephone tag block of following sizes in sheet metal enclosure of suitable
dimensions fabricated out of 16 SWG sheet steel with castle key lock,
7.00 Non DSR hinged gasketed type cover including termination of telephone cables,
making connections, painting of box etc, complete as required.

-
a 10 Pair Tel Tag Block
Nos. 32.00 273.00 8,736
Supply of following size anealed tinned copper conductor PVC insulated
and sheathed armoured copper telephone cables with suitable clamps,
10.00 Non DSR saddles on existing cable trays / raceways etc and including making terminal
joints complete as required.
-
-
a 10 Pair
Metre 2,400.00 83.00 199,200
-
Total SH 06- Telephone System
418,910

467
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-07 FIRE ALARM SYSTEM

Wiring in existing conduit : Supplying and drawing following sizes of FR PVC


insulated copper conductor , single core cable in the existing
1.00 DSR - 1.17 surface/recessed Steel /PVC conduit as required.

DSR - 2 x 1.5 sq.mm


a
1.17.2 Metre 13,000.00 36.00 468,000
DSR - 3 x 1.5 sq.mm
b
1.17.3 Metre 350.00 50.00 17,500
-
-
S/F Steel conduit : Supplying and fixing of following sizes of Steel conduits
along with accessories in surface/ recess including painting in case of
2.00 DSR – 1.20 surface conduit,or cutting the wall and making good the same in case of
recessed conduit as required.
-
20mm
DSR –
a
1.20.1
Metre 550.00 121.00 66,550
25mm
DSR –
b
1.20.2
Metre 10,000.00 142.00 1,420,000
32 mm
DSR –
c
1.20.3
Metre 200.00 193.00 38,600
-
Laying of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables including
DerivedDS excavation,supply & fiiling of sand and bricks .
3.00
R – 7.3.1
Metre 550.00 75.00 41,250
-
Layingof 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng hume pipes.
Derived
4.00
DSR – 7.5.1
Metre 250.00 15.00 3,750
-

468
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Laying of of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables on surface
Derived
5.00 including supply and fixing of G.I. Spacer, saddles etc.
DSR – 7.7.1
Metre 100.00 25.00 2,500
-
Laying of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng laid
DerivedDS Concealed/Surface conduits, cables trays.
6.00
R – 7.8.1
Metre 16,000.00 25.00 400,000
-
Supply, Installation, Testing & Commissioning of Analog Addressable type Self
Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting
base, LED, Address Switch, complete with MS Powder coated Junction Box for
7.00 NON -DSR mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends,
cable compression glands, cable tags and Ferruling. (BFC)

Nos 460.00 5,200.00 2,392,000


-
Supply, Installation, Testing & Commissioning of Analog Addressable type Self
Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting
base, LED, Address Switch, complete with MS Powder coated Junction Box for
8.00 NON -DSR
mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends,
cable compression glands, cable tags and Ferruling. (AFC)
Nos 454.00 5,200.00 2,360,800
-
Supply, Installation, Testing & Commissioning of Analog addressable Rate of
Rise Cum Fixed temperature detector with standard mounting base, LED,
Address Switch, complete with MS Powder coated Junction Box for mouting
9.00 on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.

Nos 75.00 4,400.00 330,000


-
Supply, Installation, Testing & Commissioning of Response Indicator with
matching screws complete with GI Junction box, Cable lugs at cable end
10.00
and ferruling.
Nos 500.00 118.00 59,000
-
Devices
11.00
-
-

469
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Addressable Dual Action
Manual Pull Station with Adddress Switch and all mounting accessories ,
11.01 complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 38.00 6,700.00 254,600
Supply, Installation, Testing & Commissioning of Fireman's Phone Jackwith all
mounting accessories, complete with MS Powder coated Junction Box for
11.02 mounting on Surface, Cable Lugs at Ends and all required accesories for
mounting at site complete as requried.
Nos 32.00 5,000.00 160,000
Supply, Installation, Testing & Commissioning of Addressable Module for Fire
Phone Jack with Adddress Switch and all mounting accessories, complete
11.03 with MS Powder coated Junction Box for mouting on Surface, Cable lugs at
Ends, cable compression glands, cable tags and Ferruling.
Nos 24.00 5,800.00 139,200
Supply, Installation, Testing & Commissioning of Addressable Relay Module
with Address Switch and all mounting accessories complete as required.
Shall be complete with Pilot Relay for Tripping of Third Party Equipment,
suitable for switching 5A/15A current through the Relay contacts , MS Powder
11.04 coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.

Nos 12.00 5,800.00 69,600


Supply, Installation, Testing & Commissioning of Addressable Control Module
with Address Switch and all mounting accessories, complete with MS Powder
11.05 coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.
Nos 70.00 5,800.00 406,000
Supply, Installation, Testing & Commissioning of Fault Isolator Module ,
complete with MS Powder coated Junction Box for mouting on Surface,
11.06 Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 105.00 5,100.00 535,500
-
Supply, Installation, Testing & Commissioning of Directional Sounders with
20Hz to 20 KHz operating frequency with minimum 8 distinct sound patterns
to indicate Exit doors and direct occupants for safe and fast evacuation ,
11.07
complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 32.00 21,000.00 672,000

470
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Voice
Evacuation Speaker having power taps upto 2W and frequency response of
11.08
400 to 4000Hz for Voice Evacuation.
Nos 76.00 2,300.00 174,800
Supply, Installation, Testing & Commissioning of Wall Mounted Voice
Evacuation Speaker having power taps upto 2W and frequency response of
11.09 400 to 4000Hz for Voice Evacuation.
Nos 31.00 5,400.00 167,400
Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Muli-
Candela Strobe with all required accessories for mounting complete as
11.10 required.
Nos 33.00 6,800.00 224,400
12.00 Control And Annunciation
-
-
Supply, Installation, Testing & Commissioning of Microprocessor based 10
loop capacity , Networkable Analogue Addressable type Fire Alarm Control
panel.

The FACP shall have minimum 640 character Display with fully functional
QWERTY Keypad. Each loop shall have a maximum loading of 125 detectors
and 125 devices in one loop with 20% spare capacity. Four access levels,
flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts
sealed lead acid batteries sufficient for 24 hours normal working and for 2
hours during an emergency conditions as required. The FACP shall be UL 9th
12.01 Edition Listed. FACP should be with Network Communication Module with
true peer to peer Connectivity.

Failure of Fire Alarm Panel CPU shall not result in failure of operation of
Amplifiers. Hence if the Digital Audio Amplifiers are CPU Rail Mounted,
consider 1 No. CPU dedicated for Digiital Audio Amplifier Bank.

FACP cost to include all necessary cards, modules, enclosure, CPU and
associated acccessories to complete the system design. All components
including enclosures shall be UL Listed.
Nos 1.00 971,500.00 971,500

471
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Digital Audio Amplifier / Zone
Amplifier capable of processing 1 of 8 audio channels and total of 100W at
70.7 VRMS output along with necessary enclosures. The DAA shall be fully
12.02 monitored for fault and alarm reporting. Power Amplifiers shall not be
permitted. UL Listed.
Nos 3.00 304,600.00 913,800
Supply, Installation, Testing & Commissioning of Power Supply Unit - 240VAC
to 24VDC - 6Amps. Power Supply shall be UL Listed with Necessary Battery
12.03 Backup.

Nos 1.00 64,700.00 64,700


13.00 Cabling
-
Providing, testing and installing / fixing of approved make 20 mm dia.MS
13.01 Non DSR flexible conduits on ceiling / wall / floor etc. complete with accessories like,
Junction boxes, Collars, Bends etc.
metre 515.00 60.00 30,900

Total SH 07- Fire Detection & Alarm System


12,384,350

SH-08 DATA NETWORKING

SH-08 A RESIDENTIAL BLOCK

1.00 LAN SYSTEM

Supplying & laying of PVC sheathed flame retardant Untwisted Pair


1.01 (Untwisted Pair (UTP)) Cable of Cat - 6 back bone cable for Data & Voice
outlets.
Mtr 2,800.00 53.00 148,400
Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6
1.02 RJ-45 information outlet module for Data & Voice.
Each 58.00 550.00 31,900
Supplying, installing, testing and commissioning of 24 Port Cat - 6 Untwisted
1.03 Pair (UTP) Patch Panel for Data Networking for back bone cable.
Each 2.00 17,050.00 34,100
Supplying, installing, testing and commissioning of 48 Port Cat - 6 Untwisted
1.04 Pair (UTP) Patch Panel for Data Networking for voice
Each 2.00 500.00 1,000

472
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6
1.05 Patch Cord of following length. 7ft
Each 50.00 415.00 20,750
Supplying, installing, testing and commissioning of Untwisted Pair (UTP) Cat - 6
1.06 Patch Cord of following length. 4ft

Each 100.00 350.00 35,000


Supply installation testing and commissioning 2- Port Mosaic Faceplate -
1.07 White
Each 30.00 220.00 6,600
Supply installation testing and commissioning Blank Insert For Faceplate
1.08 180.00
Each 30.00 5,400
-
2.00 Server & Wall mount Rack and cable management
-
Supply installation testing and commissioning of 600 mm x 600 mm 15 U
230 V AC 90 CFM fan 2 , three Hardware packet 1 set ( containing 20 Nos
2.01
each of 3), stationary shelf , Two Cable manager 1U height.
Each 1.00 21,750.00 21,750
Supply installation testing and commissioning 1U Horizontal Cable Manager
2.02 (For Field Cables & Switches)
Each 2.00 885.00 1,770
Supply installation testing and commissioning 6 / 12 Socket Universal Power
2.03 Strip with MCB
Each 1.00 3,000.00 3,000
Supply installation testing and commissioning Extra Hardware packets for
2.04 300.00
Racks Each 2.00 600
EDGE SWITCHES
3.00 -
Supply installation testing and commissioning 24 Port 10/100/1000Mbps + 2
ports for optional SFP/ SX Modules supporting 1G, layer 2 switch with
3.01 Stacking cable (Non-blocking switch fabric, IPv6 ready), option for RPS
Each 3.00 88,125.00 264,375
Supply installation testing and commissioning Multi-Mode SFP /SX
3.02 transceivers supporting 1G
Each 2.00 21,750.00 43,500
-
Total SH 08 A- RESIDENTIAL BLOCK
618,145

473
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-09 TV System
Supplying and fixing following modular switch/ socket on the existing
1.00 DSR-1.24 modular plate & switch box including connections but excluding modular
plate etc. as required.
TV antenna socket outlet
a DSR-1.24.7
Each 281.00 93.00 26,133
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
2.00 DSR - 1.53 recessed steel/ PVC conduit as required.
Metre 5,620.00 33.00 185,460
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
3.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.

-
DSR - 25mm
a
1.21.2 Metre 4,496.00 65.00 292,240
DSR - 32mm
b
1.21.3 Metre 200.00 32.00 6,400
-
Total SH 09- TV System
510,233

474
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY OF COST ELECTRICAL WORKS (HIGH SIDE)

SUBHE AD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

A. HIGH SIDE

SH-01 MV PANELS (ESS) 52,011,700


SH-02 MV / LV CABLING & ITS TERMINATIONS, CABLE TRAYS AND RACEWAYS 38,961,272
SH-03 SAFETY EQUIPMENTS 426,286
SH -04 RMU, HT PANELS, BUS DUCTS and OUTDOOR POLE STRUCTURE for 33 KV 19,717,658
SH -05 HT CABLES AND TERMINATIONS 817,166
SH -06 DG SETS AND EXHAUST PIPING SYSTEM 24,373,600
SH -07 HSD STORAGE AND SUPPLY SYSTEM 1,092,650
SH -08 MISCELLANEOUS ITEMS 744,710
SUB TOTAL (B) 138,145,042

LESS 5% FOR UPRNN WORKING (6,907,252)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 131,237,790

475
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DETAILED COST ESTIMATE FOR ELECTRICAL WORKS: EXTERNAL/HIGH SIDE WORKS

SH-01 MV PANELS (ESS)

1.00 Supplying,Installation, testing and commissioning of cubical type LT panel


suitable for 415V, 3 Phase,4 wire 50 Hz AC supply system fabricated in
compartmentalized design from CRCA sheet steel of 2mm thick for frame
work and covers, 3mm thick for gland plates i/c cleaning & finishing
completed 9 tank process of powder coating in approved shade,having
extensible type TPN Aluminium alloy bus bars of high conductivity,DMC/SMC
bus bar supports,with short circuit withstand capacity for 1 sec, bottom base
channel of MS section not less that 100 mm x 50mm x 5mm thick, fabrication
shall be done transportable sections,entire panel shall have a common
copper earth bar of size 25mmx5mm at the rear with 2 no's earth stud,solid
connections from main bus bar to switchgears with required size of
alunimium bus bars and control wiring PVC insulated copper conductor S/C
cable alleys,cable gland plates in two half,i/c providing following switch
gears: (with all necessary hardware, accessories as required for complete
installation as per specifications and single line digram).

Refer CPWD general specification for Electrical works Part IV Sub station

Note: 1.Provision for both Bottom & Top cable entry shall be provided in All
Panels .

All panles shall be indoor type unless otherwise mentioned. Only feeder pillers
shall be outdoor type.

MV PANELS

1.01 Non DSR Main LT Panel (ESS)

General Notes:

476
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
A. ACB:

i LSIG (Microprocessor Based) releases shall be used for incoming feeders such
as Transformers and DG Sets & LSI releases for outgoing breakers. All ACB
shall have Icu = Ics = Icw for 1 Second.

ii All 4 Pole ACB shall have fully Rated neutral equal to rating of the breaker &
shall be protected against overload & short-circuit .

iii Ready-to-close contact shall exist for indicating that all safety parameters
are checked & enabling closure of breaker, ensuring at-most safety for the
user

iv A door interlock shall be provided so that it shall not be possible to open the
door until the air circuit breaker moving part is in the disconnected position.

B. MCCB:
i. All MCCBs shall be suitable for 3 Phase 415 Volts AC 50 HZ supply

ii. All MCCBs shall have rated service breaking capacity (Ics) equal to the
ultimate breaking capacity (Icu) at defined operational voltage.

iii. All MCCBs shall clearly indicate the suitability for isolation in the name plate
identified by the symbol

iv. All MCCBs shall offer class –II front face i.e. main current path of the circuit
breaker should be isolated from auxiliary section

v. All Incomer MCCBs shall be provided with earth fault protection

vi. MCCBs of above250A Microprocessor Based and upto 250A thermal


Magnetic releases.

vii. This BOQ to be read in conjunction with technical specifications and Single
Line Diagram (attached for reference). If any discrepancy occurs that should
be brought to the notice of Client/Consultant before quoting the price
otherwise stringent condition will be deemed to have been considered.

477
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

viii. All ACBs to be provided with ON/OFF/Trip lamps, 3 NO + 3NC Auxiliary


contacts other than used in control circuit.

ix. All Transformer and DG incoming ACBs shall be provided with Microprocessor
based releases & ON/OFF/Trip / Spring charged/ready to close indicating
lamps.

x. All MCCBs shall be provided with rotary operating handle and ON/OFF lamps
backed by 2Amp control MCB.

xi. All meters shall be digital type (unless otherwise specified)

xii. Multi-function meter to be provided as required to cover all the parameters


as mentioned.

xiii. All current/voltage transformer shall be cast resin type.

xiv. All indicating lamps shall be LED type.

xv. Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus
bar is after considering all derating factors. (Bus bar sizing calculation to be
submitted for approval.)

xvi. All internal control wiring shall be heat resistant type.

xvii. All incoming breakers in Main LT panel shall be electrically interlocked.

xviii. All TP feeders shall be provided with Isolable neutral link.

xix. Bus bar chamber shall be provided at top only. Incoming and outgoing
cable entry shall be from top/bottom as required.

xx. Bus couplers in Main MV Panel shall be Microprocessor based with all
releases.

xxi. Bus couplers shall be provided with ON & OFF indicating lights but without
releases.

478
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
xxii. All feeders shall be provided with door interlocked with door defeat, pad
lock facility.

xxiii. Live parts shall not be accessible after opening the door, Transparent acrylic
sheet to be provided to cover the same.

xxiv. Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto
terminal block.

xxv. 20% spare control terminal to be provided.

xxvi. All MCCBs shall be provided with variable O/L & S/C releases. Incoming
MCCB shall be provided with E/F releases also

xxvii. All incoming/outgoing cables shall be terminated on links/terminals.

xxviii. All Panels shall have 100 % Neutral Bus Bar Rating.

xxix. Degree of protection for following type of distribution panel enclosure shall
be as per IS: 13947-1993.

IP 43 for indoor panels.

IP 55 for outdoor panels.

xxx. Painting/lettering on Breakers and distribution boards, the location they


serve, providing on each panel its circuit diagram.

1.01 Non DSR MAIN LT PANEL (SUBSTATION)

Three (3) nos. 2500kVA Transformer Incoming:

each shall have the following :

4000 A, 4-pole, 65 KA EDO type ACB (microprocessor based)

479
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Metering:

Multifunction Digital meter (consisting of Voltage, Amps, kWh, kW, P.F.


parameter) with RS 485 Port.

4000/5A, CL-1, 15VA Cast resin CT for metering.

4000/5A, CL-1, 15VA Cast resin CT for APFC relay.

Set of RYB phase indicating lamps with control MCBs.

Protection:

each shall have the following :

REF relay with 4000/1A, CL-PS Cast resin CTs. (4 Nos.). (Three nos. to be
provided in the panel & one no. CT to be supplied loose for mounting in
Transformer neutral).

Undervoltage Relay

Overvoltage Relay

Master Trip Lockout relay

Trip Circuit Supervision Relay

415/110V, 100VA PT with protection in incoming and outgoing side.

DG Power Panel Incoming:

Three (3) Nos. 4000A, 4-pole, 65 KA EDO type ACB (microprocessor based).

Metering:

480
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Multifunction Digital meter (consisting of Voltage, Amps, kWh, kW, P.F.
parameter) with RS 485 Port.

Suitable ratio, CL-1, 15VA, Cast Resin metering CTs for metering.

Set of RYB phase indicating lamps with control MCBs.

Protection:

each shall have the following

Reverse Power Relay

Undervoltage Relay

Overvoltage Relay

415/110V, 100VA PT with protection in incoming and outgoing side.

Bus Couplers

Two (2) Nos 4000A, 4-pole, EDO type ACB (microprocessor based with all
releases) (65 KA) with ON/OFF indication.

Electrical interlocking shall be provided between incomers and bus coupler


so that two supplies are not mixedup.

Busbar

481
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
5000A, 4Pole aluminium, colour coded bus bars suitable for 415V, 50Hz (after
derating).(65 KA)

Outgoing:

All outgoings shall be rating for 65 kA (Ics)

Set of RYB phase indicating lamps with control MCBs on each outgoing to be
provided. Each backed up with 2A MCB.

ON/OFF indicating lamps on each outgoing to be provided. ACB outgoing


shall be provided with Trip lamp also.

All Energy Meters in Main LT Panel are suitable for DUAL Supply (Transformer &
DG) with communication Port and shall be provided with suitable ratio CL-1,
15VA Cast resin CTs.

Control Transformer of suitable rating shall be provided with Auto Change


over scheme shall be provided to cater the control loads of the panel.

Each Outgoing shall be provided with 3-phase digital type Multifunction


meters with Communication Port.

Section : 1

Two (2) Nos. 1250A 4P MDO ACB

Two (2) Nos. 1000A 4P MDO ACB

Four (4) Nos. 800A 4P MDO ACB

Four (4) Nos. 630 A 4P MCCB

Two (2) Nos. 400 A 4P MCCB

Two (2) Nos. 200 A 4P MCCB

One (1) Nos. 160 A 4P MCCB

482
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Section : 2

Two (2) Nos. 1250A 4P MDO ACB

Eight (8) Nos. 630 A 4P MCCB

Three (3) Nos. 200 A 4P MCCB

One (1) No. 1000A 4P MDO ACB

Section : 3

Two (2) Nos. 1250A 4P MDO ACB

Two (2) Nos. 1000A 4P MDO ACB

Five (5) Nos. 800A 4P MDO ACB

Five (5) Nos. 630 A 4P MCCB

One (1) Nos. 400 A 4P MCCB

Two (2) Nos. 200 A 4P MCCB

Two (2) Nos. 160 A 4P MCCB


Set 1.00 31,933,400.00 31,933,400

Note : Necessary Provision for Connection of 300 KW Solar Supply into Main LT
Panel shall be made.

1.02 Non DSR


DG Power Panel:

Panel shall be suitable for Synchronizing

Incoming:

Four (4) Nos. 2500 Amp 4P EDO ACB, 65 KA (Microprocessor based with all
releases) (for 1500KVA DGs)

One (1) No. 1600 Amp 4P EDO ACB, 65 KA (Microprocessor based with all
releases) (for 750 KVA DG)

483
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Metering:

Five (5) Nos. (0-500V) digital voltmeter with selector switch & control MCB's

Four (4) nos. (0-2500A) Digital ammeter with Selector Switch and suitable
ratio, Cl-1, 15VA CT's

One (1) no. (0-1600A) Digital ammeter with Selector Switch and suitable ratio,
Cl-1, 15VA CT's

Protection:

Restricted earth fault Relay with 2500/1A & 1600/1A, CL-PS, 3 Nos. CTs. All CTs
to be provided inside the panel (for 4 Nos. 1500 KVA DG Set and 1 No.
750KVA DG Set incomer.

Reverse Power Relay

Undervoltage Relay

Overvoltage Relay

Under Frequency Relay

Over Frequency Relay

Master Trip Lockout relay

Trip Circuit Supervision Relay

484
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Bus Coupler:

Two (2) Nos. 4000 A 4P, 65 KA EDO type ACB (microprocessor based). The bus
couplor shall be mechanically and electrically interlocked as per the site
and IE requirements.

Bus Bar:

5000 A, 4Pole aluminium, colour coded bus bars suitable for 415V, 50Hz, 65 KA
(after derating).

Outgoing

All outgoings shall be rating for 65 kA (Ics)

Set of RYB phase indicating lamps with control MCBs on each outgoing to be
provided. Each backed up with 2A MCB.

ON/OFF indicating lamps on each outgoing to be provided. ACB outgoing


shall be provided with Trip lamp also.

Control Transformer of suitable rating shall be provided with Auto Change


over scheme shall be provided to cater the control loads of the panel.

Three (3) Nos. 4000A, 4-pole EDO ACB (65kA)


Set 1.00 13,394,500.00 13,394,500

1.03 PLC Load Sharing & Synchronizing Panel:


Non DSR

485
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Design, manufacturing, testing at works, supply, receiving, storing, inspection,
handling, assembling, installing in correct aligned position, effecting proper
connections, testing and commissioning of PLC Based Auto Start, Auto
Changeover, Auto Load Balancing ,Load Sharing & Synchronizing Panel for
complete as required and as per specifications with following components:

6 Nos under voltage monitors.

6 No. Manual/Auto selector switch.

Push buttons for Test, Accept, Reset, Fault Reset, Engine start, Engine stop,
ACB close, ACB Trip Emergency stop.

6 Nos. Joysticks for Voltage raise/lower and speed raise/lower.


1No. Manual/Auto AMF toggle switch.
24V DC semaphore, 38 mm.
PLC Hardware as required & as per specifications.
Auxiliary relays as required & as per specifications.
230V AC/24V DC, 10A, stabilized power supply with voltage trimmer &
maintenance free battery.

Annunciator as required & as per specifications.

Power Monitor based PLC Synchronizing panel for 4 Nos. 1500kVA & 1 No 750
KVA DG Sets as described above. Set 1.00 970,000.00 970,000

1.04 Non DSR


Capacitor Panel:

Design, manufacture, supply, installation, testing & commissioning of 600


KVAR capacitor bank and panel consisting of 50 KVAR capacitor unit in tier
formation; housed in an integrated cubicle type, indoor type automatic
switching 'ON' and 'OFF' control panel with dust and vermin proof hinged
and lockable doors complete with interconnections, bonding to earth and
painting (suitable for 440 Volts, 3 phase 50 Hz supply system).

486
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Panel shall be compartmentalized with liberally designed fabrication space
for ventilating the capacitor unit to limit the temperature rise as per relevant
IS Standard.

The fabrication of panel shall be done with the provision of 650 kVAR with
extended bus bar but initially we require 600 kVAR.

The sequencing of relay shall be FIRST IN FIRST OUT with time delay.

Incoming (1 No.):

1250 Amp 4P MDO ACB, 50kA

Metering & Indication:

(0-500) volts digital Voltmeter with 3 way 'ON' and 'OFF' selector switch.

(0-1250A) Digital Ammeter with ammeter selector switch and 1250/5A, CL-1,
15VA CTs.

Phase indication lamps each backed up with 2 Amps MCB and ON/OFF
switch.

Auto/Manual mode indicating lamp.

16 steps APFC Relay with Auto/Manual Selector Switch and Time Delay Relay.

Bus Bars:

1600A, TPN aluminium , colour coded sleeved bus bars suitable for 415V,
50Hz. (after deration)

Outgoing (Twelve Nos.):

487
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Each outgoing Capacitor unit shall be provided with the followings :-

125A TP MCCB (35kA), Suitable Rating Thyristor, ON/OFF indicating lamp &
push button.

Analogue Ammeter with 1 No. CT of suitable ratio.

Lower Limit (in RED colour ) & Upper Limit (in Green Colour) shall be marked
on the dial of the Ammeter.

50 kVAR (2x25 kVAR) capacitor unit

Fabrication space for One Nos. 50 kVAR (2x25 kVAR) capacitor unit
Sets 3.00 1,318,200.00 3,954,600

1.05 Non DSR Feeder Pillar (Typical)(Outdoor Type)

Incoming (1 No.):

One (1)No. 200 Amp TP MCB, 25kA

Metering & Indication:


One (1) No. 0-500 volts digital voltmeter with selector switch protected by 2A
control MCB's

One (1) No. 0-200 A Digital ammeter with Selector Switch and suitable ratio,
Cl-1, 10VA CT's

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:
300A, TPN aluminium , colour coded sleeved bus bars suitable for 415V, 50Hz.
(after deration)

488
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Outgoings

Three (3) Nos. Phase wise 24 Hrs calibrated photochramatic time switch
along with suitable contactor for automatic operation of External Lighting

Three (3) Nos. 63 A 4P MCB (10 KA)


Three (3) Nos. 63 A DP MCB (10 KA)
One (1) Nos. 40 A DP MCB (10 KA)
Six (6) Nos. 20 A SP MCB (10 KA)
Nine (9) Nos. 10 A SP MCB (10 KA)
Six (6) Nos. 6/10 A SP MCB (10 KA) Sets 6.00 158,200.00 949,200

1.06 Non DSR Fixed Type Capacitor Panel:

Design, manufacture, supply, installation, testing & commissioning of 200


KVAR Fixed Type Capacitor Bank and panel housed in an integrated cubicle
type, indoor type with dust and vermin proof hinged and lockable doors
complete with interconnections, bonding to earth and painting (suitable for
440 Volts, 3 phase 50 Hz supply system).

Panel shall be compartmentalized with liberally designed fabrication space


for ventilating the capacitor unit to limit the temperature rise as per relevant
IS Standard.

Incoming (1 No.):

400 Amp 4P MCCB, 35kA

Metering & Indication:


Phase indication lamps each backed up with 2 Amps MCB and ON/OFF
switch.

Bus Bars:
500A, TPN aluminium , colour coded sleeved bus bars suitable for 415V, 50Hz.
(after deration)

489
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Outgoing (Four Nos.):

Each outgoing Capacitor unit shall be provided with the followings :-

125A TP MCCB (35kA), Suitable Rating Thyristor, ON/OFF indicating lamp &
push button.

50 kVAR capacitor unit


Sets 3.00 270,000.00 810,000

TOTAL FOR SH-01 - MV PANELS (ESS):


52,011,700

MV / LV CABLING & ITS TERMINATIONS, CABLE TRAYS AND


SH-02 RACEWAYS

1.00 Laying of one number PVC insulated and PVC sheathed / XLPE power cable
of 1.1 KV grade of following size direct in ground including excavation, sand
DSR - 7.1
cushioning, protective covering and refilling the trench etc as required.

a Upto 35 sq. mm
DSR - 7.1.1
Metre 15,000.00 195.00 2,925,000
b Above 35 sq. mm and upto 95 sq. mm
DSR - 7.1.2
Metre 3,000.00 202.00 606,000
c Above 95 sq. mm and upto 185 sq. mm
DSR - 7.1.3
Metre 2,500.00 210.00 525,000
d Above 185 sq. mm and upto 400 sq. mm
DSR - 7.1.4
Metre 2,800.00 233.00 652,400

2.00 Laying of one number additional PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size direct in ground in the same
DSR - 7.2 trench in one tier horizontal formation including excavation, sand
cushioning, protective covering and refilling the trench etc as required.

a Upto 35 sq. mm
DSR - 7.2.1
Metre 1,000.00 133.00 133,000

490
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
b Above 35 sq. mm and upto 95 sq. mm
DSR - 7.2.2
Metre 1,500.00 141.00 211,500
c Above 95 sq. mm and upto 185 sq. mm
DSR - 7.2.3
Metre 500.00 149.00 74,500
d Above 185 sq. mm and upto 400 sq. mm
DSR - 7.2.4
Metre 500.00 171.00 85,500

3.00 MV cable laying in existing Hume Pipe :Laying of one number PVC insulated
XLPE insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of
DSR – 7.5
following size in the existing RCC/HUME/METAL pipe as required.

a Up to 35 sq.mm
DSR – 7.5.1
Metre 2,000.00 16.00 32,000
b Above 35 sq.mm and up to 95 sq. mm
DSR – 7.5.2
Metre 400.00 25.00 10,000
c Above 95 sq.mm and up to 185 sq. mm
DSR – 7.5.3
Metre 300.00 33.00 9,900
d Above 185 sq.mm and up to 400 sq. mm
DSR – 7.5.4
Metre 500.00 58.00 29,000

4.00 Laying of one number PVC insulated and PVC sheathed/XLPE power cable
DSR - 7.6 of 1.1kV grade of following size in the existing masonry open duct as
required.
a Upto 35 sq. mm
DSR - 7.6.1
Metre 1,000.00 12.00 12,000
b Above 35 sq. mm and upto 95 sq. mm
DSR - 7.6.2
Metre 500.00 20.00 10,000
c DSR-7.6.3 Above 95 Sq.mm and upto 185 Sq.mm
Mtr 100.00 27.00 2,700
d DSR-7.6.4 Above 185 Sq.mm and upto 400 Sq.mm
Mtr 600.00 50.00 30,000

5.00 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE
DSR - 7.7 power cable of 1.1 KV grade of following size on wall surface as required.

a Upto 35 sq. mm (clamped with 1mm thick saddle)


DSR - 7.7.1
Metre 500.00 24.00 12,000
b Above 35 sq. mm and up to 95 sq.mm (clamped with 25x3 mm MS Flat
DSR - 7.7.2
clamp) Metre 300.00 70.00 21,000

491
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

6.00 Laying and fixing of one number XLPE insulated and PVC sheathed power
DSR - 7.8
cable of 1.1 KV grade of following size on cable tray as required.

a Up to 35 sq.mm (Clamped with 1mm thick saddle)


DSR - 7.8.1
Metre 12,100.00 20.00 242,000
b Above 35 sq.mm and up to 95 sq. mm (Clamped with 25x3 MS Flat clamp)
DSR - 7.8.2
Metre 3,200.00 48.00 153,600
c Above 95 sq.mm and up to 185 sq. mm (Clamped with 25/40 x 3 MS Flat
DSR - 7.8.3
clamp) Metre 1,150.00 59.00 67,850
d Above 185 sq.mm and up to 400 sq. mm (Clamped with 40 x 3 MS Flat clamp)
DSR - 7.8.4
Metre 4,400.00 91.00 400,400

7.00 Supplying and making cable route marker with cement concrete 1:2:4( 1
cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) of
DSR - 7.9 size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with
thickness of 10cm including incription duly engraved as required.
Each 300.00 310.00 93,000

8.00 Supplying and fixing cable route marker with 10 cm X 10 cm X 5mm thick G.I.
plate with LT inscription there on, bolted /welded to 35mm X 35 mm X 6 mm
DSR -7.10
angle iron, 60 cm long and fixing the same in ground as required.
Each 200.00 288.00 57,600

9.00 Supplying and fixing cable route marker with 10 cm X 10 cm X 5mm thick G.I.
plate with HT inscription there on, bolted /welded to 35mm X 35 mm X 6 mm
DSR -7.10 angle iron, 60 cm long and fixing the same in ground as required.
Each 100.00 288.00 28,800

10.00 Supplying and making indoor end termination with brass compression gland
and aluminium lugs for following size of PVC insulated and PVC sheathed /
DSR - 9.1
XLPE aluminium conductor cable of 1.1 KV grade as required.

a 2 C x 6 Sqmm (19mm)
DSR - 9.1.1
Each 10.00 147.00 1,470
b 2 C x 10 Sqmm (19mm)
DSR - 9.1.2
Each 6.00 148.00 888

492
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
j DSR - 3.5 C x 35 Sqmm(32mm)
9.1.21 Each 10.00 270.00 2,700
k DSR - 3.5 C x 50 Sqmm(35mm)
9.1.22 Each 74.00 342.00 25,308
l DSR - 3.5 C x 70 Sqmm(38mm)
9.1.23 Each 26.00 382.00 9,932
m DSR - 3.5 C x 95 Sqmm(45mm)
9.1.24 Each 12.00 466.00 5,592
n. DSR - 3.5 C x 120 Sqmm(45mm)
9.1.25 Each 16.00 484.00 7,744
o. DSR - 3.5 C x 150 Sqmm(50mm)
9.1.26 Each 16.00 576.00 9,216
p DSR - 3.5 C x 185 Sqmm (57mm)
9.1.27 Each 26.00 784.00 20,384
q DSR - 3.5 C x 240 Sqmm(62mm)
9.1.29 Each 10.00 969.00 9,690
r DSR - 3.5 C x 300 Sqmm(70mm)
9.1.30 Each 84.00 1,086.00 91,224
s DSR – 3.5 C x 400 Sqmm (82mm)
9.1.31 Set 4.00 1,369.00 5,476
t DSR – 4 C x 10 Sqmm (25mm)
9.1.32 Each 10.00 193.00 1,930
u DSR - 4 C x 16 Sqmm(28mm)
9.1.33 Each 40.00 245.00 9,800
v DSR - 4 C x 25 Sqmm(28mm)
9.1.34 Each 24.00 248.00 5,952
w Non DSR 4 X 6 sq. mm
Each 20.00 125.00 2,500
x Non DSR 4 X 4 sq. mm
Each 8.00 125.00 1,000
ab Non DSR 2 X 10 sq. mm
Each 20.00 365.00 7,300
ac Non DSR 2 X 6 sq. mm
Each 20.00 302.00 6,040

493
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
11.00 Supplying and making straight through joint with heat shrinkable kit including
ferrules and other jointing materials for following size of PVC insulated and
PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.

a 3.1/2 core 50 sq. mm.


DSR-9.4.19
Nos 10.00 1,622.00 16,220
b 3.1/2 core 70 sq. mm.
DSR-9.4.20
Nos 10.00 1,660.00 16,600
c 31/2 core 95 sq. mm.
DSR-9.4.21
Nos 12.00 1,936.00 23,232
d 3.1/2 core 120 sq. mm.
DSR-9.4.22
Nos 2.00 2,298.00 4,596
e 3.1/2 core 150 sq. mm.
DSR-9.4.23
Nos 2.00 2,298.00 4,596
f 3.1/2 core 185 sq. mm.
DSR-9.4.24
Nos 6.00 2,599.00 15,594
g 3.1/2 core 240 sq. mm.
DSR-9.4.26
Nos 4.00 2,645.00 10,580
h 3.1/2 core 300 sq. mm.
DSR-9.4.27
Nos 4.00 3,343.00 13,372
i 3.1/2 core 400 sq. mm.
DSR-9.4.28
Nos 4.00 4,738.00 18,952

12.00 Supply, loading, transportation unloading at site, storages at site ,shifting


from storage place to site of following sizes of XLPE insulated PVC sheathed,
Non DSR FRLS, Aluminium conductor armoured power cable of 1.1 KV grade
conforming to IS amended upto date and as per specifications

a 2 C x 10 Sqmm Metre 500.00 105.00 52,500


b 2 C x 6 Sqmm Metre 5,000.00 90.00 450,000
c 3 C x 10 Sqmm Metre 500.00 140.00 70,000
d 3 C x 6 Sqmm Metre 110.00
1,000.00 110,000
e 3 C x 4 Sqmm Metre 100.00
2,000.00 200,000

494
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
f 3.5 C x 400 Sqmm Metre 1,590.00
200.00 318,000
g 3.5 C x 300 Sqmm Metre 7,000.00 1,265.00 8,855,000
h 3.5 C x 240 Sqmm Metre 600.00 1,055.00 633,000
i 3.5 C x 185 Sqmm Metre 1,200.00 835.00 1,002,000
j 3.5 C x 150 Sqmm Metre 1,150.00 690.00 793,500
k 3.5 C x 120 Sqmm Metre 2,000.00 595.00 1,190,000
l 3.5 C x 95 Sqmm Metre 1,000.00 475.00 475,000
m 3.5 C x 70 Sqmm Metre 1,700.00 390.00 663,000
n 3.5 C x 50 Sqmm Metre 6,000.00 305.00 1,830,000
o 3.5 C x 35 Sqmm Metre 500.00 240.00 120,000
p 4 C x 25 Sqmm Metre 1,200.00 215.00 258,000
q 4 C x 16 Sqmm Metre 2,000.00 170.00 340,000
r 4 C x 10 Sqmm Metre 1,000.00 160.00 160,000
s 4 C x 6 Sqmm Metre 1,500.00 115.00 172,500
t 4 C x 4 Sqmm Metre 200.00 105.00 21,000

13.00 Supply, loading, transportation unloading at site, storages at site ,shifting


from storage place to site of following sizes of XLPE insulated PVC sheated,
Non DSR FRLS, Copper conductor armoured power Cable of 1.1 KV grade conforming
to IS 7098 amended upto date.

a 4C x 25 Sqmm Metre 2,200.00 1,005.00 2,211,000


b 4C x 16 Sqmm Metre 8,000.00 660.00 5,280,000
c 4C x 10 Sqmm Metre 1,000.00 465.00 465,000
d 4C x 6 Sqmm Metre 300.00 330.00 99,000
e 4C x 4 Sqmm Metre 500.00 235.00 117,500
f 2C x 6 Sqmm Metre 300.00 195.00 58,500
g 2C x 4 Sqmm Metre 200.00 155.00 31,000

495
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
14.00 Supply, loading, transportation unloading at site, storages at site ,shifting
from storage place to site of following sizes of XLPE insulated PVC
Non DSR sheated,FRLS ,Copper conductor Flexible Cable of 1.1 KV grade conforming
to IS 7098 amended upto date.

a. 1C x 70 sq.mm
Metre 200.00 675.00 135,000
b 1C x 25 sq.mm
Metre 200.00 270.00 54,000
c 1C x 16 sq.mm
Metre 300.00 185.00 55,500

15.00 Supplying and laying of following 1100 volts grade PVC insulated sheathed
copper conductor armoured control cables in existing trenches cables trays,
clamped on wall with suitable saddles, fixing bolts, including testing and
commissioning.
a 2 core 2.5 sq mm PVC insulated copper conductor armoured control cables
MR
RM 500.00 115.00 57,500
b 4 core 2.5 sq mm PVC insulated copper conductor armoured control cables
MR
RM 1,000.00 170.00 170,000
c 7 core 2.5 sq mm PVC insulated copper conductor armoured control cables
MR
RM 200.00 255.00 51,000
d 10 core 2.5 sq mm PVC insulated copper conductor armoured control
MR
cables RM 300.00 320.00 96,000

16.00 Cable end termination with brass double compression gland and copper
Non DSR lugs for following size of XLPE insulated and PVC sheathed copper condutor
cable of 1.1kV grade as required with earthing.

a 4 X 25 sq. mm (CU)
Each 30.00 622.00 18,660
b 4 X 16 sq. mm (CU)
Each 140.00 560.00 78,400
c 4 X 10 sq. mm (CU)
Each 20.00 545.00 10,900
d 4 X 6 sq. mm (CU)
Each 16.00 160.00 2,560
e 4C x 4 Sqmm
Each 10.00 121.00 1,210
f 2C x 6 Sqmm
Each 6.00 302.00 1,812
g 2C x 4 Sqmm
Each 4.00 302.00 1,208
h 1C x 70 sq.mm (CU)
Each 4.00 383.00 1,532

496
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
i 1 X 25 sq. mm (CU)
Each 6.00 121.00 726
j 1 X 16 sq. mm (CU)
Each 6.00 121.00 726

17.00 Cable end termination of the following PVC insulated sheathed copper
conductor control cables of 1100 volt grade including supplying and fixing
of COPPER lugs. Double compression glands with earthing

a MR 7 core 2.5 sq.mm Control cable


No. 20.00 275.00 5,500
b MR 10 core 2.5 sq.mm Control cable
No. 30.00 400.00 12,000

18.00 Supply, installation, testing and commissioning of GI Perforated type cable


trays factory fabricated out of sheet steel with perforation not more than
17.5%, channel size 75 x 15 mm and rung size 30 x 6 mm, spaced at 250 mm
interval, supporting angle frame at every 1.8 m, bottom angle fasteners,
anchor grip bolts, etc. The tray shall be suspended from ceiling using anchor
Non DSR
bolt and angle iron supports or mounted from wall. The rate shall include all
accessories like bends, elbows, tees, coupler plates, with all necessary
hardware, accessories as required for complete installation.

a 1000 mm width x75mm depth x 2.0 mm thick


Metre 100.00 1,586.00 158,600
b 900 mm width x75mm depth x 2.0 mm thick
Metre 100.00 1,453.00 145,300
c 750 mm width x75mm depth x 2.0 mm thick
Metre 500.00 1,234.00 617,000
d 600 mm width x75mm depth x 2.0 mm thick
Metre 300.00 1,022.00 306,600
e 450 mm width x50 mm depth x 2.0 mm thick
Metre 400.00 999.00 399,600
f 300 mm width x50 mm depth x 1.6 mm thick
Metre 1,000.00 890.00 890,000
g 150 mm width x50 mm depth x 1.6 mm thick
Metre 300.00 352.00 105,600

497
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
19.00 Supply and fixing GI ladder type cable Trays, with radial bends, support of
following sizes.The rate shall include all accessories like bends, elbows, tees,
Non DSR coupler plates, with all necessary hardware, accessories as required for
complete installation.

a 450 mm wide

Runners - 20 x 75 x 20 x 2.5 mm

Rungs - 20x30x20x2.5, 250mm C/C


RM 500.00 750.00 375,000
b 300 mm wide

Runners - 20 x 75 x 20x2.5 mm

Rungs - 20x30x20x2.5 mm 250mm C/C


RM 500.00 550.00 275,000
20.00 GI Raceways:
Supply, fixing, laying and embedding in underfloor GI raceway of following
sizes complete with all accessories including junction box with 3 mm thick
Non DSR cover plate,neoprene gasket in joints ,cutting the floor and jamming the
raceway with all necessary hardware (including civil works) as required.

a 50 x 38 x 1.6mm
Metre 500.00 361.00 180,500
b 100 x 38 x 1.6mm
Metre 600.00 521.00 312,600
c 150 x 38 x 1.6mm
Metre 350.00 671.00 234,850
d 200 x 38 x 1.6 mm
Metre 600.00 826.00 495,600
e 300 x 38 x 1.6 mm
Metre 500.00 1,130.00 565,000
21.00 Providing and fixing of fire retardant sealant on wall / floor crossings
Sqmtr 50.00 7,953.00 397,650

TOTAL FOR SH-02 - MV / LV CABLING & ITS TERMINATIONS, CABLE


TRAYS AND RACEWAYS 38,961,272

498
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-03 SAFETY EQUIPMENTS

1.00 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of
mild steel,atleast 2mm thick,and vitreous enamelled white on both sides,and
Non DSR with inscription in single red colour on front side as required.
Each 2.00 150.00 300

2.00 Providing and fixing HT danger notice plate of 250 mm X 200 mm, made of
mild steel,atleast 2mm thick,and vitreous enamelled white on both sides,and
Non DSR with inscription in single red colour on front side as required.
Each 2.00 150.00 300

3.00 Supply and fixing wooden framed covered with glass shock treatment chart
Non DSR printed on cloth in English ,Hindi & Local language.
Job 8.00 200.00 1,600

4.00 Supply and fixing suitable size wooden framed covered with glass for Main
Non DSR Panel SLD in electrical room as per IE rules fixed to wall as required.
Job 2.00 900.00 1,800

5.00 Supply and providing ISI marked electrical 1.1 kV grade 10 mm thick anti-skid
Non DSR rubber mat as per IS:5424 with upto date ammendment. Sqm 30.00 1,600.00 48,000

6.00 Supply, installation, testing and commissioning of Standard First aid box
Non DSR complete with all accessories as required.
Each 8.00 904.00 7,232

7.00 Supply, installation, testing and commissioning of Rubber chequered mat of


Non DSR size 2000 x 1000 x 12 mm thick, 1100 V grade as required.
Each 10.00 3,477.00 34,770

8.00 Floor mounted bucket stand with GI buckets to hand 4 nos. of 13 ltrs buckets
sand filled. The stand shall be 5'(L) x 3'(H) x 2"(W) made out of 30 x 300 x4mm
Non DSR MS angle frame duly coated with 2 coats of red oxide primer & 2 coats of
red finish paint
Each 12.00 857.00 10,284

499
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
9.00 Supply and fixing in position 1000 mm wide rubber matting of 33 KV grade as
per electricity rules. Thickness of rubber mat shall be not less than 12 mm.
Non DSR

RM 20.00 1,000.00 20,000

12.00 Portable 5 kg. dry type fire extinguisher suitable for electrical fire and as
Non DSR recommended by the tariff advisory committee.
Each 4.00 8,000.00 32,000

13.00 Supply and fixing of in-position the fire extinguishers dry chemical power
Non DSR (ABC) 5 kg capacity.
No. 4.00 9,500.00 38,000

14.00 Supply and fixing of in position the fire extinguishers dry chemical power
Non DSR (ABC) 2 kg capacity.
No. 2.00 4,000.00 8,000

15.00 Supply and fixing of tool kit with all standard tools such as screw driver ,
Non DSR spaner etc as required.
Each 4.00 5,500.00 22,000

16.00 Supply of 33kV pair of hand gloves


Non DSR Set 2.00 400.00 800

17.00 Supply of 33kV pair of hand gloves


Non DSR
Set 2.00 600.00 1,200

18.00 Supply and fixing of cable/ busbar 33kV earthing truck/ trolley
Non DSR
No. 2.00 65,000.00 130,000

19.00 Supply and fixing of cable/ busbar 33kV earthing truck/ trolley
Non DSR
No. 2.00 35,000.00 70,000

TOTAL FOR SH-03- SAFETY EQUIPMENT


426,286

500
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
RMU, HT PANELS, BUS DUCTS and OUTDOOR POLE STRUCTURE for
SH -04 33 KV

1.00 Supply, istallation , testing & commissioning of compact RMU (Ring main
unit).comprising 2 Nos. 33 KV , 800 A, 21 KA incoming isolators and one unit
SF6 breaker and earth switch bus bars, interlocking and earth bar complete
NONDSR with snap action mechanism for manual operation, F.PI(Fault position
Indication), bushing for 800A, arc proof cable cover complete with
interlocking Set 3,913,199.00
1.00 3,913,199

2.00 33KV, VCB PANEL BOARD (INDOOR TYPE)

Supply, installation, testing and commissioning of Indoor 33kV extendable HT


panel board. The panel shall be complete with cable termination
arrangement for incoming & outgoing XLPE, 33 KV cables. The panel shall
comprise of the following:

2.10 Single Panel Board (Near HT Metering):

Incoming & Outgoing :

33 KV, 26.24KA, 800A VCB with motorised spring charge closing mechanism
with antipumping protection and trip free features ,motor voltage 230V AC
and tripping / closing coil voltage , 110V DC and VCB complete with 3 NO +
3 NC auxillary switch contact as spare complete with followings :

230V AC spring charge meter.

24V DC shunt trip coil.

Sets of three phase drawout type PT of ratio 33KV :√3 /110v :√3 , Class. 1.0 per
phase with control fuses.

501
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Sets of 100/60/5A, class 1.0 accuracy, 15 VA current transformer (cast resin)
for metering .

Sets of 100/60/5A, class 1.0 accuracy, 15 VA current transformer (cast resin)


for metering (for one incomer).

Digital trivector meter with RS 485 port having function : A, V, KW, KVAR, KVA,
KWH, MDI, Hz, PF for incoming feeders.

Master trip relay similar to PQ8 or equivalent.

Trip circuit supervision relay similar toTCS or equivalent.

Breaker control switch : (TNC)

Sets of phase & breaker ON/OFF indicating lamps.

Three pin socket + switch.

Sets of circuit breaker ON/OFF/Autotrip / Spring charged/Trip circuit healthy


indicating lamp(LED type)

Power Pack 24V DC, 17AH– 1 No

100W anticondensation space heater / thermostat

Mechanical ON/OFF/Trip indication.


Set 1.00 975,164.00 975,164

2.11 Four Panel Board :

502
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Incoming (1 No.):

33 KV, 26.24KA, 800A VCB with motorised spring charge closing mechanism
with antipumping protection and trip free features ,motor voltage 230V AC
and tripping / closing coil voltage , 110V DC and VCB complete with 3 NO +
3 NC auxillary switch contact as spare complete with followings :

230V AC spring charge meter.

24V DC shunt trip coil.

Sets of three phase drawout type PT of ratio 33KV :√3 /110v :√3 , Class. 1.0 per
phase with control fuses.

Sets of 100/60/5A, class 1.0 accuracy, 15 VA current transformer (cast resin)


for metering .

Sets of 100/60/5A, class 1.0 accuracy, 15 VA current transformer (cast resin)


for metering (for one incomer).

Digital trivector meter with RS 485 port having function : A, V, KW, KVAR, KVA,
KWH, MDI, Hz, PF for incoming feeders.

O/C, E/F relay type SPAJ140C or equivalent with 3 nos. over current & one
earth fault element with IDMT relay with shunt trip on 24volts DC, consisting 3
element over current relay with setting from 50 to 200% and earth fault with
setting from 20 to 80% .

Master trip relay similar to PQ8 or equivalent.

503
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Trip circuit supervision relay similar toTCS or equivalent.

Breaker control switch : (TNC)

Sets of phase & breaker ON/OFF indicating lamps.

Three pin socket + switch.

Sets of circuit breaker ON/OFF/Autotrip / Spring charged/Trip circuit healthy


indicating lamp(LED type)

100W anticondensation space heater / thermostat

Mechanical ON/OFF/Trip indication.

Busbar:

33KV, 26.24KA rectangular electrolytic grade colour coded and sleeved


copper busbar.

Outgoing : Three (3) Nos.

each shall have the following:

33 KV, 26.24KA , 800A, EDO type VCB with motorised spring charge closing
mechanism with antipumping protection and trip free features , motor
voltage 230V AC and tripping / closing coil voltage , 110V DC and VCB
complete with 3 NO + 3 NC auxillary switch contact as spare complete with
followings :

230V AC spring charge meter.

24V DC shunt trip coil.

504
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
(0-60) digital Ammeter with selector switch and required CTs. (for 3 Nos.
Outgoings)

Sets of 60/30/5A ,class 1.0 accuracy, 15 VA current transformer (cast resin) for
metering (for 3 nos. outgoing).

Sets of 60/30/5A ,class 5P10 accuracy current transformer (cast resin) for
protection (for 3 Nos. outgoing).

Sets - O/C, E/F relay type SPAJ140C or equivalent with 3 nos. over current &
one earth fault element with IDMT/inst. relay with shunt trip on 24volts DC,
consisting 3 element over current relay with setting from 50 to 200% and earth
fault with setting from 20 to 80% .

Master trip relay similar to PQ8 or equivalent.

Trip circuit supervision relay.

Sets of auxillary relay similar to VAA33 or equivalent.

Breaker control switch : (TNC)

Set of phase and breaker ON/OFF indicating lamps.

Three pin socket and switch.

Sets of circuit breaker ON / OFF / Autotrip / Spring charged / Trip circuit


healthy indicating lamp (LED type)

100W anticondensation space heater / thermostat

505
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Mechanical ON/OFF/Trip indication.

Note:-

Potential free contact to be provided for HT trouble in each breaker to be


used for annunciation in the control room.

The potential free contacts for transformer troubles annunciation & trips for
WTI should be provided for remote annunciation in the control room.
Required contactors / control relays with sufficient NO/NC contacts shall be
provided.

Each O/G feeder to be provided with 8 window annunciator.

HT Panel described above & as per specification.


Set 1.00 4,063,062.00 4,063,062

2.12 Design, supplying, erection, connecting, testing and comissioning of 24 Volt


DC 180 AH supply system comprising of one set of batteries and battery
charger with Boost charger and float charger including control wiring for
alarm and trip circuit complete suitable for operating the control devices of
HT panel. Sets 1.00 194,933.00 194,933

3.00 Bus Duct (In sandwich construction)

Design, manufacture, supply, installation & testing of following Rating 4 Pole


Aluminum bus duct (testing and commissioning at work site in co-ordination
with contractor) of following items suitable rating (50 KA for 1 Sec.) 4P bus
duct of Aluminium bus bars, sandwich type with heat shrinkable H-class
insulation sleeves with expansion joints, Fire barriers including necessary
NON-DSR supports and louvers for ventilation, Bus trunking enclosure shall be made of
minimum 1.6 mm thick galvanized steel / extruded aluminium with epoxy
polyster powder coating of approved colour on outside as per specification
including 2 Nos. of 50 x 6 mm Aluminium earthing conductor through out the
length of the bus duct. (These sequence should be matched with
Transformer and Panel)

506
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Fire barriers including necessary supports and louvers for ventilation,


fabricated out of extruded alumminium painted with approved paint shade
NON-DSR as per specification including 2 No. of 50 x 6 mm G.I. earthing conductor
throughout the length of the bus duct. (Phase sequence shall be matched).

a 4000 amps (Trx to MLTP , DG Power Panel to MLTP)


RM 60.00 37,700.00 2,262,000
b 2500 amps (1500 KVA DG to DG Power Panel)
RM 80.00 26,100.00 2,088,000
c 1600 amps (750 KVA DG to DG Power Panel)
RM 20.00 16,400.00 328,000
4.00 Following four pole copper flexible end connections on transformers & LT
NONDSR Isolator Panels.

a 4000 amps Nos. 12.00 144,700.00 1,736,400


b 2500 amps Nos. 8.00 92,300.00 738,400
c 1600 amps Nos. 2.00 46,200.00 92,400

5.00 RISING MAINS

5.10 Design, manufacture, supply, assembling, installation in correct assigned


position, making proper connections, testing and commissioning of following
rating TPN rising mains of aluminium bus bar with class F insulation, tap-off
connection points , expansion joints, fire barriers including necessary
support and louvers for ventilation, fabricated including 2 Nos. of 50 x 6
mm GI earthing conductor through out the length of the rising mains
(Phase sequence should be matched with the incoming breaker
provided at LT Panel). Thrust pad shall be provided for each rising main
for necessary support to rising main and to prevent the bus bar
expansion in downward direction. Also end cover to close the end of
rising main and to provide extra supports to bus bars at end shall be
provided. Dimension to be furnished with the offer.

507
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

a 400 Amp. 4P (Aluminium)


RM 60.00 10,500.00 630,000
b 600 Amp. 4P (Aluminium)
RM 50.00 12,000.00 600,000
c 800 Amp. 4P (Aluminium)
RM 50.00 13,500.00 675,000

5.20 Design, manufacture, supply, assembling, installation in correct assigned


position, making proper connections, testing and commissioning of following
rating Reducer fabricated out of 14 / 16 gauge CRCA sheet steel in cubical
formation, dust and vermin proof, coupled with rising mains.

a 600 Amps to 400 Amps TPN Rising Main Nos 3.00 9,100.00 27,300
b 800 Amps to 600Amps TPN Rising Main Nos 3.00 9,500.00 28,500

5.30 Design, manufacture, supply, assembling, installation in correct assigned


position, making proper connections, testing and commissioning of following
rating Adopter Boxes fabricated out of 14 / 16 gauge CRCA sheet steel in
cubical formation, dust and vermin proof, coupled with rising mains. Boxes
shall be treated with all anticorrosive process before powder coating as per
specifications. 2 No. earthing terminals shall be provided. Boxes shall be
suitable for connecting of rising mains at top and aluminium cables at
bottom.
a 600 Amps End Feed Unit with 600 Amp 4P MCCB
Nos 1.00 61,900.00 61,900
b 800 Amps End Feed Unit with 800 Amp 4P MCCB
Nos 2.00 92,700.00 185,400
5.40 Supply of cubical type tap off box fabricated out of 2 mm thick M.S. sheet,
dust and vermin proof, with hinged detachable doors and painted front,
comprising indication lamps with toggle switches 1 No. 100 Amp TPN Pole
MCCB of 25 KA breaking capacity terminated directly with tap off box
with Bus Bar links on the incoming side and suitable for cable connection
on the outgoing side including making connections, interconnections, fixing
at designated location, testing commissioning, earthing, incluiding outgoing
cables complete as required.
Nos 65.00 17,200.00 1,118,000

Total SH 04-RMU, HT PANELS, BUS DUCTS and OUTDOOR POLE


19,717,658
STRUCTURE for 33 KV

508
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH -05 HT CABLES AND TERMINATIONS

The rates under this section shall also include the following:

Providing and fixing approved cable supports and grouting the same as
required.

Effecting proper connections at terminations.

Ensuring that provision is left in buildings and trenches as the work proceeds,
for incorporating of cable supports at a later date.

Providing all, fixing accessories such as clamping devices, nuts and bolts etc.

Clamping to supports where laid in trenches.

Providing proper supports for cable terminals as called for.

Wherever cables cross walls provide proper sleeves at the time of civil work.

1.00 Laying of one number PVC insulated and PVC sheathed / XLPE power cable
of 33 KV grade of following size direct in ground including excavation, sand
cushioning, protection covering and refilling the trench etc as required.

a DSR-8.5.2 Above 120 Sq.mm and upto 400 Sq.mm Mtr 280.00
120.00 33,600

2.00 Laying of one number additional PVC insulated and PVC sheathed / XLPE
power cable of 33 KV grade of following size direct in existing RCC trench in
one tier horizontal formation including dressing , saddling on angle iron
supports.
a DSR-8.6.2 Above 120 Sq.mm and upto 400 Sq.mm Mtr 120.00 199.00 23,880

3.00 Laying of one number PVC insulated and PVC sheathed / XLPE power cable
DSR - 8.7 of 33 KV grade of following size in the existing RCC/ HUME/ METAL pipe as
required.

509
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
a DSR-8.7.2 Above 120 Sq.mm and upto 400 Sq.mm Mtr 80.00 36.00 2,880

4.00 Supplying and making indoor cable end termination with heat shrinkable
jointing kit complete with allaccessories including lugs suitable for following
DSR-10.7
size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required.

a 240 Sq.mm
DSR-10.7.3
Each 14.00 14,225.00 199,150

5.00 Supply and making outdoor cable end termination with heat shrinkable
jointing kit complete with all accessories including lugs suitable for following
size of 3 core , XLPE aluminium conductor cable of 33 KV grade as required.

a 240 Sq.mm
DSR-10.8.3
Each 2.00 19,128.00 38,256

6.00 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing
of sides lift upto 1.5m, including getting out the excavated soil , refilling with
DSR-14.4 sand and or good soil after laying of cable / pipe etc in layers of 20 cm,
ramming, watering and disposal of surplus excavated soil as directed, with a
lead of 50 meters. Cum 215.00
100.00 21,500

7.00 Excavation of cable trenches in hard rock not exceeding 1.5 meters in width,
and lift upto 1.5 metres, including getting out the excavated soil and disposal
DSR-14.6
of excavated soil as directed within a lead of 50 metres.
Cum 100.00 379.00 37,900

8.00 Supplying of following size 33 KV grade XLPE aluminium conductor armoured


NONDSR cables.

a 3 C x 240 sq.mm 33 KV XLPE cable


RM 200.00 2,300.00 460,000

Total SH 05- HT CABLES AND TERMINATIONS


817,166

510
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DG SETS AND EXHAUST PIPING SYSTEM


SH -06

1.00 Supply, installation, testing and commissioning of powder coated acoustic


enclosure suitable for 1500 KVA DG set for outdoor application as per
NONDSR
specification complete with all accessories as required including ventilation
system. No deration in DG set capacity shall be accepted on this account.

Set 4.00 1,158,900.00 4,635,600

2.00 Exhaust Piping

Supply, erection, testing and commissioning of exhaust piping Min. 6mm


Thick of following sizes with welding joint including bends, MS pipe supports,
clamps, dash fastener, nuts, bolts etc.,with first layer of insulation 25mm thick
NONDSR ceramic fiber wool (96Kg/Cub. Mtr.) & second layer minimum 50mm thick
rockwooll (150Kg/Cub Mtr.) covered with 26 SWG aluminium sheet claddings
etc. complete as required and as per specifications.

a 500 mm dia. NB
Mtrs. 180.00 8,500.00 1,530,000
b 350 mm dia. NB
Mtrs. 50.00 8,500.00 425,000

3.00 Supporting MS Structure


Exhaust pipe supporting system with suitable size M.S channel, M.S angle, M.S
flat, dash fastners, nut, bolt etc. complete including 1 coat of redoxide & 2
NONDSR coat of enamel paint and other Accessories as required at the site of work.

Kgs. 3,000.00 85.00 255,000

4.00 Supply, erection, testing and commissioning of motorized fuel transfer


NONDSR pumps as required.

Nos. 2.00 14,000.00 28,000

511
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing and Commissioning of 1 No. 500 KVA DG Set and
its allied work for giving power back to Residential Block includes AMF
Control Panel, related switchgear (ACB, MCCB) relays, synchronizing panels,
5.00 NONDSR cabling, control cabling, cable trays, chemical earthing, Meter etc. and
other related item to complete the job.

LS 1.00 17,500,000.00 17,500,000

Total SH 06-DG SETS AND EXHAUST PIPING SYSTEM 24,373,600

SH -07 HSD STORAGE AND SUPPLY SYSTEM

1.00 Supplying, installing, testing and commissioning of underground Horizontal


cylindrical HSD storage tank (6mm thick shell and 8 mm thick plain ends)
installation including the following :

a Inlet and outlet connections.


b Vent pipe with flame arrester.
c Dip pipe assembly with calibration chart, complete with cap with locking
arrangement with dip stick engraving in it.

d 550 mm internal dia manhole with cover.


e Cleats for anchoring (4 Nos.)
f Lifting lugs :-

(The design, fabrication, pressure testing, corrosion protection, anchoring,


earthing etc. will be done strictly as per IS:10987-1992 and duly approved by
'CCOE' suitable for underground installation.)

g 15 KL capacity HSD tank size (approx.) 1950 mm dia (shell outside diameter)
NON DSR & 5500 mm long (overall length).
Set 1.00 400,000.00 400,000

512
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.00 Supply, installation, testing & commissioning of flame proof electrical driven
rotary gear pumps suitable for pumping of HSD consisting of following & as
per IS 2148. (Pump shall be suitable for automatic/manual operation as
NONDSR
required) Self priming gear pump with weather protection cover for motor.
[Location : HSD Yard ].

Horizontally mounted single stage capable of delivering 35 LPM at 30 Mtr.


Head while running at required 1440 RPM, complete with proper connection
to suction and delivery line, bypass arrangement against over pressure.

Flame proof motor suitable for 415 + 10% V, 3 phase, 50 Hz AC supply and of
suitable HP for the above pumps.

Flame proof on-off push button station of required rating suitable for the
above motor without no volt coil including connection, interconnection in
switch board.

Common base plate of required strength manufactured out of cast iron.

Suitable RCC foundation and anti vibration damping arrangement with


cushy foot or similar mounting arrangement.

Coupling and coupling guard for direct coupling of pump and motor.

Pressure gauge with valve on the delivery side.

Strainer at inlet - 32 mm dia

The pump set as described above (1w + 1 standby)


Set 2.00 50,000.00 100,000

513
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.00 Providing, fixing, testing & commissioning of M.S. class `C' (heavy duty)
exposed pipes conforming to IS : 1239 and fittings like tees, elbows, junctions,
unions, bends, plugs, flanges etc. clamps, structural supports as required/
directed at site including cutting & making good the walls, floors, RCC work
NONDSR etc. cutting chases & filling the same with cement concrete 1:3:6 (1 cement
:3 coarse sand :6 graded stone aggregate 20 mm nominal size) or cement
mortar 1:4 (1 cement :4 coarse sand) as required including painting the pipes
with desired shade of enamel paint over a coat of primer.

Location : Inside Plant Room

a 25 mm dia
RM 100.00 135.00 13,500
b 32 mm dia
RM 100.00 180.00 18,000
c 40 mm dia
RM 200.00 245.00 49,000
d 50 mm dia
RM 50.00 275.00 13,750
e 65 mm dia
RM 50.00 310.00 15,500

4.00 Supply, installation, testing and commissioning of MS class C (heavy duty)


pipe in trenches including fittings like tees, elbows, unions, bends plugs etc.
NONDSR for fuel oil piping including provision of supports etc. Provision of 6 mm
Pypcoat anticrossive treatment to the pipe

a 40 mm dia
RM 50.00 450.00 22,500
b 50 mm dia
RM 50.00 510.00 25,500

5.00 Supply, installation, testing & commissioning of CI plug valve of the following
NONDSR sizes suitable for pressure of 10 Kg / Sqcm complete with all necessary fittings
(Audco)

a 25 mm dia Nos. 4.00 250.00 1,000

514
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.00 Supply, installation, testing & commissioning of GM non-return valves of the
NONDSR
following sizes G.M. suitable for pressure of 10 Kg / Sqcm complete with all
necessary fittings. (Audco)

a 40 mm dia Nos. 4.00 350.00 1,400

7.00 Supply, installation, testing & commissioning of gun metal float valve with
copper float ball and brass rod of required length suitable for pressure of 10
NONDSR
Kg / sqcm complete as required.

a 32 mm dia Nos. 6.00 600.00 3,600

8.00 Providing and fixing level controller for day oil storage tanks, including wiring,
cabling, probes, solenoid valve suitable for HSD fuel and with all other
NONDSR
accessories ready for automatic operation of fuel oil pump complete as
required. Sets 4.00 8,000.00 32,000
9.00 Providing and fixing Y strainer for oil supply line
a 40 mm dia Nos. 6.00 4,750.00 28,500
b 50 mm dia Nos. 6.00 5,600.00 33,600
10.00 Supply, installation, testing and commissioning of 990 litres capacity day oil
storage tank fabricated from 4 mm thick MS plates. Cost of Tank shall include
provision of 450 mm ID Manhole cover, level indicator & flanged connection
NONDSR for inlet, outlet, overflow, vent, drain, boiler return and provision for installing
probes of level controller Tank shall be mounted on 2m high steel structure
support with access ladder (painted with 2 coats of Red Oxide Primer)
Set 4.00 20,000.00 80,000
11.00 On 80 mm dia Fuel line [For unloading] with 50 mm dia Oil flow meter, 3 Nos.
NONDSR 80 mm dia valve, 1 No. basket strainer (suitable for 15000 Ltr. Per Hr. flow)
Set 2.00 8,000.00 16,000

12.00 Providing and fixing rubber hose suitable for HSD service at unloading point 3
NONDSR Mtr. Length with coupling joints.

a 65 mm dia
Nos. 2.00 4,000.00 8,000

515
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Tank Anchorage & Earthing Work :

Underground H.S.D. tank anchorage by means of steel flats of round bars


having adequate cross section to resist the uplift at a stress level of 137.00
2
Mpa (1400 Kgf/cm ).

13.00 HSD tank earthing as per clause/para 11.5.4 of IS : 10987-1992 and fuel pipe
NONDSR line earthing as per IPR-1972.
LS 1.00 6,500.00 6,500
14.00 Supply, installation, testing & commissioning of automatic level controller with
low level & high level cut off and alarm indication including all fitting, control
NONDSR
cabling and accessories.

a HSD Buffer tank


Set 1.00 20,000.00 20,000
b HSD Over flow tank
Set 1.00 20,000.00 20,000
15.00 Providing, fixing, testing & commissioning of approved quality GM float with
NONDSR copper ball float and brass rod required length of following sizes :-

a 40 mm dia Each 2.00 350.00 700


FIRE PROTECTION EQUIPMENTS:

16.00 Providing & fixing of Fire Buckets (6 nos.) with stand having capacity of 9 liters
NONDSR conforming to relevant BIS specifications.
Each 2.00 5,400.00 10,800
17.00 Providing & fixing Fire Extinguishers mechanical foam type having capacity
NONDSR of 9 liters (for fighting oil fires) in accordance with OISD standard - 117
Each 4.00 18,000.00 72,000
18.00 Providing & fixing of 'No Smoking' and 'No Unauthorized Entry' signboards in
NONDSR English and Hindi, as per IPR- 1970.
Each 2.00 350.00 700
BUFFER TANK :
19.00 Supply, installation testing & commissioning 990 Ltr. Cap. Buffer Tank for HSD
to be installed in DG room & Boiler Room. The tank shall be fabricated from
5 mm thick MS plates. Tank shall be provided with all necessary nozzles for
inlet, out let, vent, drain, overflow and 450 mm dia manhole for easy access
for cleaning & maintenance. Tank shall be provided with float & Board type
level Indicator.

516
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
HSD Buffer Tank 990 Ltrs. capacity (1000x1000x1000 mm deep) with all
NON-DSR accessories.
Set 1.00 20,000.00 20,000
OVER FLOW TANK:

20.00 Supply, installation, testing & commissioning of 990 Ltrs. Capacity overflow
tank for HSD overflowing from day oil tanks installed in the DG room & Boiler
Room. The tank shall be fabricated from 5 mm thick M.S. plates. Tank shall be
having necessary nozzles for inlet, outlet, vent, drain, overflow and a
manhole of 550mm dia for easy access to all equipments/instruments inside
the tank and shall also include float operated level indicator. Tank shall be
placed at 450 mm below finished floor level inside plant room. All
equipments/instruments inside or near this tank to be of flameproof
construction.

HSD overflow tank 990 litres capacity (1000 x 1000 x 1000 mm deep) with all
NONDSR accessories as above.
Set 1.00 20,000.00 20,000
21.00 Structural Steel platform for Buffer tank fabricated from beams, Channels,
angles, plates, chequrered plates etc. of suitbales heights to be erected in
NONDSR DG room.

Kg. 500.00 105.00 52,500


22.00 Providing, Installing, testing & commissioning of ultrasonic level transmitter
(siemens make) in undergrounding HSD storage tanks. The level indicator
NONDSR shall be provided in electrical control panel. Cost of electrical cabling from
level transmitter to level indicater to be included in this item.
Set 1.00 6,000.00 6,000
Starts/stop, level indication shall be interface with BMS. necessary potential
Note: free contacts shall be provided in local control station, panels.

23.00 Providing, Fixing testing & commissioning of CI Foot valve including all fitting
NONDSR & accessories.

a 50 mm dia
Each 2.00 800.00 1,600
Total SH 07-HSD STORAGE AND SUPPLY SYSTEM
1,092,650

517
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH -08 MISCELLANEOUS ITEMS

1.00 Deduct for not consolidation by ramming and watering while refilling with
14.5 sand or good soil in cable/Pipe laying
Cum 100.00 48.00 4,800
2.00 Providing, laying and fixing following dia G.I. pipe (medium class) in ground
complete with G.I. fittings including trenching (75 cm deep) and re-filling etc
14.13
as required

a 14.13.1 50 mm dia metre 100.00 348.00 34,800


b 14.13.2 80 mm dia metre 100.00 555.00 55,500
c 14.13.3 100 mm dia metre 200.00 765.00 153,000
3.00 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in
ground complete with RCC collars, jointing with cement mortar 1:2 (1
14.14
cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as
required.
a 14.14.1 100 mm dia metre 300.00 287.00 86,100
b 14.14.2 150 mm dia metre 50.00 328.00 16,400
c 14.14.3 250 mm dia metre 50.00 394.00 19,700
d 14.14.4 300 mm dia metre 200.00 496.00 99,200
GI SLEEVES
4.00 Non DSR Providing and fixing of the following size medium class GI pipe sleeves

a 100 mm. dia. Metre 10.00 803.00 8,030


b 150 mm. dia. Metre 10.00 1,266.00 12,660
c 200 mm. dia. Metre 20.00 2,197.00 43,940
d 300 mm. dia. Metre 20.00 3,279.00 65,580
5.00 Supply and installation of following RCC (NP-2 class) Hume pipe, including
Non DSR
providing 75 mm thick cement concrete all around pipe 1:3:6 (1
cement, 3 coarse sand and 6 crushed stone aggregate).

a 150 mm dia ID RM 100.00 475.00 47,500


b 200 mm dia ID RM 100.00 575.00 57,500
c 300 mm dia ID RM 50.00 800.00 40,000
Total SH 08-MISCELLANEOUS ITEMS 744,710

518
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY OF COST (MISCELLANEOUS BUILDINGS)

SUBHEAD OF WORKS
SUBHE AD ESTIMATED
NO AMOUNT IN INR

A. MISCELLANEOUS BUILDINGS

SH-01 POINT WIRING AND ACCESSORIES: 1,893,551

SH-02 MV PANELS & DISTRIBUTION BOARDS 841,838

SH-03 EARTHING SYSTEM 1,507,142

SH-04 LIGHT FIXTURES AND FANS: 6,714,555

SH-05 TELEPHONE SYSTEM 2,200,886

SH-06 FIRE ALARM SYSTEM 2,333,645

SH-07 TV System 322,800


SUB TOTAL (A) 15,814,417

LESS 5% FOR UPRNN WORKING (790,721)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 15,023,696

519
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DETAILED COST ESTIMATE FOR ELECTRICAL WORKS: MISC BUILDINGS

SH-01 POINT WIRING AND ACCESSORIES:

Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable in surface /
1.00 DSR - 1.3 recessed steel conduit, with modular switch, modular plate, suitable GI box
and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor
single core cable etc as required.

a DSR-1.3.3 Group C
Point 300.00 1,003.00 300,900

Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed steel conduit, 2 way
2.00 DSR - 1.4 modular switch, modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as
required. Point 25.00 1,069.00 26,725

Wiring for circuit/ submain wiring along with earth wire with the following sizes
of FRLS PVC insulated copper conductor, single core cable in surface/
3.00 DSR -1.7
recessed steel conduit as required

2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire


b DSR - 1.7.2
Metre 200.00 200.00 40,000
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c DSR - 1.7.3
Metre 50.00 231.00 11,550
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d DSR - 1.7.4
Metre 315.00
100.00 31,500

Wiring for light/power plug with 2X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
along with 1 no. 4sq.mm., FRLS PVC insulated, copper conductor single core
4.00 DSR – 1.12
cable for loop earthing as required.(UPS Power)

Metre 600.00 162.00 97,200

520
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Wiring for light/power plug with 2X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
5.00 DSR – 1.12 along with 1 no. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required.(RawPower)
Metre 1,000.00 162.00 162,000

Wiring for light/power plug with 4X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
6.00 DSR – 1.13 along with 2 nos. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required. (UPS Power)
Metre 5.00 275.00 1,375

Wiring for light/power plug with 4X4 sq. mm., FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit
7.00 DSR – 1.13 along with 2 nos. 4sq.mm., FRLS PVC insulated, copper conductor single core
cable for loop earthing as required.(RawPower)

Metre 700.00 275.00 192,500

Wiring for Circuit/Submain Wiring alongwith earth wire with the following sizes
of FRLS PVC insulated, copper conductor,single core cable in
8.00 DSR – 1.14
surface/recessed medium class PVC conduit as required.

DSR – 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire


a Metre 106.00
1.14.1 4,000.00 424,000
DSR – 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
b Metre 131.00
1.14.2 100.00 13,100
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c DSR-1.14.3
Metre 100.00 162.00 16,200
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d DSR-1.14.4
Metre 200.00 221.00 44,200

Supplying and drawing following sizes of FRLS PVC insulated copper


9.00 DSR-1.17 conductor, single core cable in the existing surface/ recessed steel/ PVC
conduit as required.

1 x 1.5 sq. mm
a DSR-1.17.1
Metre 100.00 22.00 2,200

521
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2x 1.5 sq. mm
b DSR-1.17.2
Metre 100.00 36.00 3,600
3x 1.5sq. mm
c DSR-1.17.3
Metre 100.00 50.00 5,000
4x 1.5 sq. mm
d DSR-1.17.4
Metre 100.00 63.00 6,300
DSR- 2 x 2.5 sq. mm
k
1.17.11 Metre 100.00 53.00 5,300
DSR- 2 x 4 sq. mm
t
1.17.20 Metre 100.00 77.00 7,700
DSR- 2 x 4 sq. mm
u
1.17.21 Metre 100.00 109.00 10,900

Supplying and fixing of following sizes of steel conduit along with accessories
in surface/recess including painting in case of surface conduit, or cutting the
10.00 DSR-1.20 wall and making good the same in case of recessed conduit as required.

20 mm
a DSR-1.20.1
Metre 50.00 121.00 6,050
25 mm
b DSR-1.20.2
Metre 100.00 142.00 14,200
32 mm
c DSR-1.20.3
Metre 100.00 193.00 19,300
40 mm
d DSR-1.20.4
Metre 100.00 287.00 28,700
50 mm
e DSR-1.20.5
Metre 50.00 387.00 19,350
Supplying and fixing of following sizes of medium class PVC conduit along
with accessories in surface/recess including cutting the wall and making
11.00 DSR-1.21
good the same in case of recessed conduit as required.

a DSR-1.21.1 20 mm
Metre 100.00 53.00 5,300
b DSR-1.21.2 25 mm
Metre 200.00 65.00 13,000
c DSR-1.21.3 32 mm
Metre 100.00 85.00 8,500
d DSR-1.21.4 40 mm
Metre 100.00 110.00 11,000
e DSR-1.21.5 50 mm
Metre 100.00 144.00 14,400

522
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing metal box of following sizes (nominal size) on surface or
in recess with suitable size of phenolic laminated sheet cover in front
12.00 DSR-1.22 including painting etc as required.

75 mm X 75 mm X 60 mm deep
a DSR-1.22.1
Each 100.00 89.00 8,900
150 mm X 75 mm X 60 mm deep
c DSR-1.22.3
Each 50.00 111.00 5,550
150 mm X150 mm X 60 mm deep
d DSR-1.22.4
Each 100.00 160.00 16,000
Supplying and fixing following modular switch/ socket on the existing
13.00 DSR-1.24 modular plate & switch box including connections but excluding modular
plate etc. as required.

a DSR-1.24.1 5/6 amps switch


Each 100.00 81.00 8,100
2 way 5/6 amps switch
b DSR-1.24.2
Each 50.00 96.00 4,800
15/16 amp switch
c DSR-1.24.3
Each 25.00 111.00 2,775
3 pin 5/6 amp socket outlet
d DSR-1.24.4
Each 20.00 79.00 1,580
6 pin 15/16 amp socket outlet
e DSR-1.24.5
Each 25.00 150.00 3,750
Telephone socket outlet
f DSR-1.24.6
Each 10.00 95.00 950
TV antenna socket outlet
g DSR-1.24.7
Each 10.00 94.00 940
Bell push
h DSR-1.24.8
Each 10.00 111.00 1,110
S/F Modular Type Blanking Plate : Supplying and fixing modular blanking
plate ,on the existing modular plate & switch box excluding modular plate
etc. as required.
14.00 DSR - 1.26

Each 30.00 23.00 690

523
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
S/F GI Box along with modular plate: Supplying and fixing following size
/modules, GI box along with modular base & cover plate for modular
15.00 DSR – 1.27 switches in recess etc as required.

DSR – 1 or 2 Module(75mmx75mm)
a
1.27.1 Each 205.00 166.00 34,030
3 Module (100mmX75mm)
b DSR-1.27.2
Each 45.00 175.00 7,875
4 Module (125mmX75mm)
c DSR-1.27.3
Each 50.00 195.00 9,750

Supply & fixing following modular base and cover plate for modular
16.00 DSR - 1.28 switches in recess etc as required.

DSR - 1 or 2 Module
a Each 79.00
1.28.1 205.00 16,195
DSR - 3 Module
b Each 88.00
1.28.2 45.00 3,960
DSR - 4 Module
c
1.28.3 Each 50.00 97.00 4,850

Supplying and fixing 3 pin, 5 amp ceiling rose ,on the existing junction box
17.00 DSR - 1.33 including connection etc. as required.
Each 200.00 43.00 8,600

Supplying and fixing brass batten/angle holder including connection etc. as


18.00 DSR - 1.34 required.
Each 50.00 74.00 3,700

Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
19.00 DSR - 1.36 including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.
Each 100.00 163.00 16,300

524
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying and fixing stiff pendent with 600 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
20.00 DSR - 1.37 including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and painting etc. as required.

Each 50.00 163.00 8,150

Supplying and fixing call bell/ buzzer suitable for single phase,230 Volts,
21.00 DSR - 1.38 complete as reqired.
Each 10.00 61.00 610

Providing and fixing 16/0.20mm (0.50sqmm) twin flat flexible,FRLS PVC


insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or
22.00 DSR - 1.39 side of the table/ door etc. as required.
Each 50.00 21.00 1,050

Providing and fixing 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC
insulated, PVC sheathed copper cable direct on the wall with PVC clips etc.
23.00 DSR - 1.40 . as required.
Each 50.00 19.00 950

Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug


DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
24.00
minus1.20. insulated, copper conductor single core cable for loop earthing as
1) required.(UPS Power)
Metre 500.00 107.00 53,500

Power plug wiring in Raceway (2 x 4 sq.mm) - Wiring for light/power plug


DRDSR with 2X4 sq. mm., FRLS PVC insulated, copper conductor, single core cable
(1.5 in existing surface/recessed raceway along with 1 no. 4sq.mm., FRLS PVC
25.00
minus1.20. insulated, copper conductor single core cable for loop earthing as
1) required.(RawPower)
Metre 500.00 107.00 53,500

525
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Wiring for the following light points with 1.5 sq.mm PVC insulated
copper conductor 1100 volts grade stranded flexible FRLS wires of
approved make in concealed or surface mounted 25 mm dia medium
26.00 DRDSR class PVC conduit controlled by SPMCB provided in the DB and earthing of
fixtures with 1.5 sq.mm PVC insulated copper conductor stranded flexible
FRLS wire.(Cost of MCB not to be included here)

One point controlled by one MCB.


a
Points 50.00 228.00 11,400
Two points controlled by one MCB.
b
Points 20.00 456.00 9,120
Three points controlled by one MCB.
c
Points 5.00 684.00 3,420
Four points controlled by one MCB.
d
Points 2.00 912.00 1,824
Five points controlled by one MCB
e
Points 2.00 1,140.00 2,280
Six points controlled by one MCB.
f
Points 1.00 1,368.00 1,368
Seven points controlled by one MCB.
g
Points 1.00 1,596.00 1,596
Eight points controlled by one MCB.
h
Points 1.00 1,824.00 1,824
Nine points controlled by one MCB.
I
Points 2.00 2,052.00 4,104
Ten points controlled by one MCB.
j
Points 5.00 2,280.00 11,400

Supplying and fixing 250x150x75 mm deep, 1.6 mm thick G I Junction box


27.00 NON DSR with coverplate complete as per site requirement.
Nos 50.00 500.00 25,000

TOTAL FOR SH-1 - POINT WIRING AND ACCESSORIES: - 1,893,551

526
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-02 MV PANELS & DISTRIBUTION BOARDS
Providing and fixing following rating and breaking capacity MCCB in existing
cubicle panel board including drilling holes in cubicle panel, making
1.00 DSR - 2.2
connections, etc. as required.

100 Amp, 16 KA, TP MCCB


a DSR - 2.2.1
Each 3,205.00
4.00 12,820
200 Amp, 25 KA , TP MCCB
b DSR - 2.2.5 Each 8,814.00
2.00 17,628
400 Amp, 35 KA , TP MCCB
c DSR - 2.2.9
Each 1.00 17,372.00 17,372
2.00 DSR - 2.3 S/F prewired SP MCB DB : Supplying and fixing following way single pole and
neutral,sheet steel MCB distribution board 240 volt,s on surface/recess,
complete with tinned copper bus bar , neutral bus bar , earth bar , din bar ,
interconnections , power painted including earthing etc. as required .(But
without MCB/RCCB/Isolator ).

a DSR - 2.3.5 2+4 way /6 Way ,Double Door Each 923.00


3.00 2,769
b DSR - 2.3.6 2+6 Way / 8 Way,Double Door Each 1,041.00
1.00 1,041
c DSR - 2.3.7 2+8 Way / 10 way,Double Door Each 1,132.00
1.00 1,132
S/F prewired TP MCB DB : Supplying and fixing following way prewired TP&N
MCB distribution board of steel sheet for 415 volts on surface/recess,
complete with loose wire box, terminal connectors for all incoming and
outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper
3.00 DSR - 2.8
conductor up to terminal blocks , tinned copper bus bar , neutral link , earth
bar , din bar , detachable gland plate , interconnections , power painted
including earthing etc. as required .(But without MCB/RCCB/Isolator ).

4 way (4 + 12 ),Double Door


a DSR – 2.8.5
Each 1.00 7,357.00 7,357
8 way (4 + 24 ),Double Door
b DSR – 2.8.7
Each 10.00 10,405.00 104,050
12 way (4 + 36 ), Double Door (LPDB)
c DSR – 2.8.8
Each 10.00 12,782.00 127,820

527
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

S/F vertical type prewired Vertical Type MCB DB : Supplying and fixing
following way prewired Vertical Type TP&N MCB distribution board of steel
sheet for 415 volts on surface/recess, complete with loose wire box of sheet
steel, dust protected, duly powder painted, inclusive of 200 amps tinned
copper bus bar, common neutral link, earth bar , din bar for mounted MCB's,
4.00 DSR - 2.9 terminal connectors for all incoming and outgoing circuits, duly prewired
with adequate size of FRLS PVC insulated copper conductor upto the
terminal connector/neutral link, earthing etc. as required .(But without
MCB/RCCB/Isolator ). (Note: Prewired vertical type MCB TPDB is normally used
where 3 phase outlets are required.)

a DSR - 2.9.5 4 Way Double Door Each 5.00 7,901.00 39,505


b DSR - 2.9.7 8 way Double door Each 2.00 11,123.00 22,246

S/F 'C' Curve , SP MCB : Supplying and fixing 5 amps to 32 amps, rating,
240/415 volts, 'C' Curve , miniature circuit breaker suitable for inductive load
5.00 DSR - 2.10 of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.

DSR - Single Pole


a Each
2.10.1 600.00 169.00 101,400
DSR - Single Pole and Neutral
b
2.10.2 Each 35.00 441.00 15,435

S/F SP MCB blanking plate : Supplying and fixing single pole blanking plate in
6.00 DSR - 2.11 the existing MCB DB complete etc.as required.
Each 3.00 7.00 21

S/F DP MCB isolator : Supplying and fixing following rating, double pole , 240
volts, isolator in the existing MCB DB complete with connections, testing and
7.00 DSR - 2.12
commissioning etc. as required.

DSR - 40 amps
a
2.12.1 Each 5.00 218.00 1,090

528
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
S/F FP MCB isolator : Supplying and fixing of following rating, four pole , 415
8.00 DSR - 2.13 volts, isolator in the existing MCB DB complete with connections, testing and
commissioning etc. as required.

DSR - 40 amps
a
2.13.1 Each 42.00 659.00 27,678
DSR - 63 amps
b
2.13.2 Each 22.00 670.00 14,740
S/F SPN RCCB :Supplying and fixing following rating, double pole, (single
phase and neutral), 240 volts, residual current circuit breaker (RCCB), having
9.00 DSR - 2.14 a sensitivity current upto 300 milliamperes in the existing MCB DB complete
with connections, testing and commissioning etc. as required.

DSR - 25 amps
a
2.14.1 Each 3.00 1,645.00 4,935
DSR - 40 amps
b
2.14.2 Each 65.00 1,714.00 111,410
Supplying and fixing following rating, four pole, (three phase and neutral),
415 volts, residual current circuit breaker (RCCB), having a sensitivity current
10.00 DSR - 2.15 upto 300 milliamperes in the existing MCB DB complete with connections,
testing and commissioning etc. as required.

DSR - 40 amps
a
2.15.2 Each 1.00 1,714.00 1,714
DSR - 63 amps
b
2.15.3 Each 5.00 2,237.00 11,185
Supplying and fixing DP sheet steel enclosure on surface/ recess along with
16/25/32amps 240 volts "C" curve DP MCB complete with connections, testing
11.00 DSR - 2.16
and commissioning etc. as required.
Each 10.00 617.00 6,170
Supplying and fixing TP sheet steel enclosure on surface/ recess along with
16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing
12.00 DSR - 2.17
and commissioning etc. as required.
Each 10.00 868.00 8,680

529
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
S/F 20 A SPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 240
Volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed
plug top along with 20 Amps, C-Curve, SP MCB, in sheet steel enclosure, on
13.00 DSR - 2.18
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 50.00 954.00 47,700
S/F 20 A TPN MCB industrial socket outlet : Supplying and fixing 20 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 20 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
14.00 DSR - 2.19
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 1.00 1,967.00 1,967
S/F 30 A TPN MCB industrial socket outlet : Supplying and fixing 30 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 30 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
15.00 DSR - 2.20
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 1.00 2,473.00 2,473
S/F 63 A TPN MCB industrial socket outlet : Supplying and fixing 63 Amps, 415
Volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed
plug top along with 63 Amps, C-Curve, TP MCB, in sheet steel enclosure, on
16.00 Non DSR
surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Each 3.00 6,500.00 19,500
S/F 20 A SPN MCB socket outlet : Supplying and fixing 20 Amps, 240 Volts,
SPN, socket outlet, with 2 pole and earth , plug top along with 20 Amps, C-
Curve, SP MCB, in weather proof enclosure/Floor Junction Box, on surface or
17.00 Non DSR
in recess, complete with connections, testing and commissioning etc. as
required.(Weather Proof Type)
Each 1.00 4,500.00 4,500
S/F 20 A TPN MCB socket outlet : Supplying and fixing 20 Amps, 415 Volts, TPN,
industrial type socket outlet, with 4 pole and earth along with 20 Amps, C-
Curve, TPN MCB, in weather proof enclosure/Floor Junction Box, on surface
18.00 Non DSR
or in recess, and complete with connections, testing and commissioning etc.
as required. (Weather Proof Type)
Each 15.00 5,500.00 82,500
Supply & Fixing of Four Pole 63 A Manual Change over Switch with Powder
19.00 Non DSR Coated Matalic Encloser as required.
Each 5.00 5,000.00 25,000
TOTAL FOR SH-2 - MV PANELS & DISTRIBUTION BOARDS: 841,838

530
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-03 EARTHING SYSTEM


G.I. earth pipe electrode with Salt/Charcoal : Earthing with GI earth pipe 4.5
Mtr long , 40 mm dia including accessories and providing masonary
1.00 DSR - 5.2 enclosure with cover plate having locking arrangement and watering pipe
etc with charcoal/coke & salt as required.
Set 20.00 3,926.00 78,520
G.I. earth plate electrode : Earthing with GI earth plate 600mm X 600mm X 6
mm thick including accessories and providing masonary enclosure with
2.00 DSR - 5.4 cover plate having locking arrangement and watering pipe of 2.7 metre
long etc. with charcoal/coke and salt as required.
Set 38.00 4,490.00 170,620
Copper earth plate electrode : Earthing with Copper earth plate 600mm X
600mm X 3 mm thick including accessories and providing masonary
3.00 DSR - 5.6 enclosure with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/coke and salt as required.
Set 16.00 9,292.00 148,672
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground
as strip earth electrode, including connection/ terminating with G.I. nut, bolt,
4.00 DSR - 5.8 spring, washer etc. as required. (Jointing shall be done by overlapping and
with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Metre 100.00 753.00 75,300
Supplying and laying 25mm x 5 mm GI strip at 0.50 m below ground as strip
earth electrocde, including connection/terminating with G.I. nut, bolt, spring,
5.00 DSR - 5.9 washer etc. as required. (Jointing shall be done by overlapping and with 2
sets of G.I nut bolt & spring washer sapced at 50mm).
Metre 500.00 109.00 54,500
Providing & Fixing 25mm x 5 mm Copper strip in 40 mm dia G.I. Pipe from
earth electrode including connection with brass nut, bolt, spring, washer
6.00 DSR - 5.10 excavation and re-filling etc. as required.
Metre 100.00 1,082.00 108,200
Providing & Fixing 25mm x 5 mm G.I. Strip in 40 mm dia G.I. pipe from earth
electrode including connection with G.I. nut, bolt, spring, washer excavation
7.00 DSR - 5.11
and re-filling etc. as required.
Metre 100.00 421.00 42,100

531
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Providing and laying earth connection from earth electrode with 6 SWG dia
G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection
8.00 DSR - 5.12
with G.I. thimble excavation and re-filling as required.
Metre 100.00 151.00 15,100

Providing and fixing 25mm X 5mm Copper strip on surface or in recess for
9.00 DSR - 5.14 connections etc. as required.
Metre 50.00 856.00 42,800
Providing and fixing 25mm X 5mm GI strip on surface or in recess for
10.00 DSR - 5.15 connections etc. as required.
Metre 50.00 142.00 7,100
Providing and fixing 6 SWG dia GI wire on surface or in recess for
11.00 DSR – 5.16 connections etc. as required.
Metre 100.00 35.00 3,500
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for
12.00 DSR - 5.20. connections etc. as required.
Metre 20.00 1,599.00 31,980
Supplying and fixing earth bus of 50mmx6mm GI strip on surface for
13.00 Non DSR connections etc as required.
Metre 600.00 350.00 210,000
60 mm x 10 ( or 50 x 12) mm x 1.2 mtrs length copper earth bus bar with
a MR insulators, making suitable size holes etc as required
Sets 50.00 2,500.00 125,000
60 mm x 10 ( or 50 x 12) mm x 1.2 mtrs length GI earth bus bar with insulators,
making suitable size holes etc as required
b MR
Sets 50.00 2,500.00 125,000
Providing and fixing OF 50 mm x 10 mm thick copper tape.
c MR
RM 50.00 1,950.00 97,500
Providing and fixing 8 SWG GI wire.
d MR
RM 18.00
9,000.00 162,000
Providing and laying GI tape 32 mm X 6 mm from earth electrode directly in
14.00 DR DSR ground as required.
Metre 50.00 185.00 9,250

TOTAL FOR SH-3 - EARTHING SYSTEM 1,507,142

532
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-04 LIGHT FIXTURES AND FANS:

S/F Modular Type Electronic Fan Regulator : Supplying and fixing stepped
type electronic fan regulator on the existing modular plate & switch box
1.00 DSR - 1.25
including connections but excluding modular plate etc. as required.
Nos 10.00 284.00 2,840

ITC fluoresent fitting directly on surface : Installation ,testing and


commissioning of pre-wired .fluorescent fitting /compact fluorescent fitting of
all types ,complete with all accessories and tube etc.directly on ceiling/wall
2.00 DSR - 1.41 ,including connection with 1.5 sq.mm FRLS PVC insulated ,copper conductor
,single core cable and earthing etc.as required.

Nos 65.00 91.00 5,915

ITC fluoresent fitting on false ceiling : Installation ,testing and commissioning


of pre-wired .fluorescent fitting /compact fluorescent fitting of all types
DRDSR - ,complete with all accessories and tube etc.directly on ceiling/wall ,including
3.00 connection with 1.5 sq.mm FR PVC insulated ,copper conductor ,single core
1.41
cable and earthing etc.as required.
Nos 10.00 149.00 1,490

ITC Ceiling Fan : Installation ,testing and commissioning of ceiling fan


including wiring the down rods of standard length (upto 30 cm) with 1.5
4.00 DSR - 1.44
sq.mm FR PVC insulated ,copper conductor ,single core cable etc.as
required. Nos 10.00 95.00 950

Installation, testing and commissioning of ceiling fan, including wiring the


down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated,
5.00 DSR - 1.45 copper conductor, single core cable, including providing and fixing
phenolic laminated sheet cover on the fan box etc. as required.
Nos 10.00 122.00 1,220

533
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

POLE ERECTION
6.00
Erection of metallic pole of the following length in cement concrete 1:3:6(1
cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
6.1 DSR - 11.3 foundation including excavation and refilling etc. as required

a DRDSR Below 4.5meter


Nos 29.00 1,100.00 31,900
DSR - Above 4.5 metre and upto 6.5 metre
b
11.3.1 Nos 60.00 2,539.00 152,340

Supplying and embedding following dia G.I. pipe (medium class) in pole
collar/ foundation (during casting) for cable entry including bending the
6.2 DSR - 11.6
pipe to the required shape complete as required.

DSR - 32 mm dia
a
11.6.1 metre 300.00 285.00 85,500
40 mm dia
DSR -
b
11.6.2 325.00
metre 200.00 65,000

Supply of 1 x 18 W indoor decorative surface mounted/hanging LED light


fixtures suitable for 1 no. of 18W LED lamps prewired complete with all
7.00 NON DSR
accessories required as per Insta Power D-Lite LX/18 W.
Nos 20.00 2,800.00 56,000

Supply of 1 x 28 W indoor decorative surface mounted/hanging LED light


fixtures suitable for 1 no. of 28 W LED lamps prewired complete with all
8.00 NON DSR accessories required as per Insta Power Lite Master 4`.
Nos 10.00 2,300.00 23,000

Supply of 2 x 28 W indoor decorative surface mounted/hanging LED light


fixtures suitable for 2 nos. of 28 W LED lamps prewired complete with all
9.00 NON DSR
accessories required as per Insta Power Lite Master 4`.
Nos 25.00 4,000.00 100,000

534
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply of Bulk Head Light fixture with lamp complete with all accessories etc
10.00 NON DSR as required. Insta Power Bulkhead
Nos 10.00 1,800.00 18,000

Supply of Mirror Light aesthetic wall/ceiling mounted luminaire suitable for 1


x TCH 14W , with low loss electronic ballast, 14W TCH lamp complete with all
11.00 NON DSR accessories etc as required. Philips make (Vector 14W TCH 207) or Bajaj
Make - BTIP 114 ACR.
Nos 10.00 461.00 4,610

Supply of 70W metal halide down lighter with CRCA housing brightened
anodized reflector and heat resistant glass cover with control gear and all
mounting accessories including 70W metal halide lamp complete with all
12.00 NON DSR
accessories etc as required. Philips make(MBS050/70W) or Bajaj Make -
BJDRN 70 MH DE, Wipro Make : WCH 50070
Nos 5.00 3,600.00 18,000

Supply of inbuilt battery backup emergency light complete with all


accessories etc as required. Legrand Make CAT No. 572222 White or Bajaj
13.00 NON DSR
Make - BTIR 128 with Battery Backup, Prolite Make Emergency Light..
Nos 25.00 2,500.00 62,500

Supply, installation, testing and commissioning of Bollard Light Fixture with all
material as required and civil works for foundation etc. Philips FGC 100 1 x PL
14.00 NON DSR 9 W, Wipro FBP 32118 1 x 18 W CFL (TC-D), Bajaj : BJ BOL 03 29 CFL
Nos 250.00 5,000.00 1,250,000

Supply, installation, testing and commissioning of 70W Pole light with all
material as required to be mounted on existing 3 mtr poles. Philips Cat No :
SGP301 1x SON 70 W FG, Wipro Cat No : WST / H50 WST - 50070 1x 70 W
15.00 Non DSR
HPSV(E),Bajaj Cat No :BGEST 0270 MH IP FFGWOB (For External Lighting)

Nos. 65.00 4,000.00 260,000

Supply, installation, testing and commissioning of 3W Planter uplighter fixture


(LED Bush Light LANDSCAPES) Make: SIMES S.3594 / Wipro-LF15-003-045 / Bajaj-
16.00 NON DSR
BJCB 118
Nos 130.00 904.00 117,520

535
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, installation, testing and commissioning of Spike Light fixture
17.00 NON DSR (LANDSCAPES) Make: Philips Smart LED Spot BGP310 WW/NW
Nos 315.00 2,000.00 630,000

Supply, installation, testing and commissioning of Water Tight Light fixture


18.00 NON DSR (LANDSCAPES) Make: Insta Power Pathfinder or equivalent.
Nos 35.00 4,000.00 140,000

Supply, installation, testing and commissioning of Floor Light fixture


19.00 NON DSR (LANDSCAPES) Make: Insta Power Pathfinder or equivalent.
Nos 100.00 4,000.00 400,000

Supply and fixing of Driver over light fixture. Make: philips NG012 / Wipro FDQ
20.00 NON DSR 45050 / Bajaj BJOS 70 SV
Nos 5.00 626.00 3,130

Supply and fixing of Pole light Asymmetrical Make: Simes S.3960w / Wipro FWP
21.00 NON DSR 22118 / Bajaj BJFL 70 SVS

Nos 10.00 2,000.00 20,000

Supply and fixing of 250 W high performance flood light luminaire suitable for
use with HPSV lamp SON-T 150W luminaire complete with , Glass cover,
control gear, capacitor, 150W HPSV lamp, etc. The rate shall include the cost
22.00 NON DSR
of necessary fixing arrangements Make: Philips MPF900 1x SON -TP 250 W IC A
WH.
Nos 25.00 6,300.00 157,500

Supply & erection of LED solar street light of appropriate size suitable for
50Lux level at ground level with mounting height of fittign 5-7 meter from
ground with IP 65 ingress protection with 37W LED ,p.f. >0.95 with transparent
23.00 NON DSR lens, including solar poles & its erection, solar lighting fixtures, inbuilt solar
panel internal wiring etc. to complete the work as per instruction of Engineer
-In -Charge. (Light fitting Similar to PHILIPS/GE/WIPRO)
Nos 5.00 107,148.00 535,740

536
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply of single arm M.S. steel tubular pole class "B" having suitable
dimension complete duly painted with two coats of red oxide paint and
one coat of bituminous paint for the 1/6 th length which is to be embeded in
ground & two coates of aluminium paint for the remaining portion. The poles
24.00 NON DSR shall be supplied with bottom welded MS base plate of suitable size and 2
runs of 25 mm dia B-Class GI pipe having total length1.2 meter each.The rate
shall also include mild steel bracket if required, required nut ,bolts, etc to
complete the work in approved manner.

3.5 mtr height with 60mm dia


a Nos 65.00 9,000.00 585,000
6 mtr height with 75 mm dia
b Nos 18,000.00
24.00 432,000

Supply and erecting street light bracket suitable for above steel tubular
welded pole for fixing of 1 no HPSV street light fixture of any rating,with 40mm
dia 2mm long "B'' grade M.S. pipe welded to pole cap of 125 mm dia
25.00 NON DSR x600mm long duly welded with supporting M.S. plate of 3mm and with bolts
of suitable size duly painted two coats of red oxide paint and 2 coat of
aluminium paint and duly wired in approved manner.
Nos 89.00 1,500.00 133,500

Supply, installation, testing and commissioning of pole for post Top light SPC
26.00 NON DSR 101 with 70 watt SON with 80mm dia GI pipe, 3.5 mtr high pole.
No. 4.00 5,000.00 20,000

Gate light fitting similar to FPM 41125 WIPRO mounted on a 63 dia 1.0m high
27.00 NON DSR MS pole
No. 4.00 3,000.00 12,000

Supply , installation, testing & commissioning of 20/21 mtr high mast complete
in respects including lighting fixtues, lamps, wiring / cabling upto terminal
28.00 NON DSR
box. The mast shall have the following specifications:-

a Structure - Material of constructions - Hot rolled MS Plate


No. of Sections - (3) , Base section - 5mm thick, middle section - 4 mm thick &
upper section - 4 mm

537
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Length of each section - 7.115 mtr

Top - Face to face inside - 200 mm

Bottom - Face to face inside - 450 mm

Circular Base plate - 725 x 32 mm

No. of foundation bolts - 8 Nos.

b Dynamic loading - Max. design wind speed - 180 KM / Hr

c Lantern Carriage - Ring - Inside dia - 800 mm

Capacity - 750 Kg

d Double drum winch - Capacity - 75 Kg


Operation - Motorized
Gear ration - 53:1

e Stainless steel wire rope , No. of rope - 2 for winch & 3 for lantern

Dia - 6 mm

construction - 7/19 with central core ss

Breaking load - 2300 Kg.

Power load - 3 Phase , 415 V


f
wattage - 1.1 KW

reversible - Yes

Lighting fixtures - 10 Nos. 2 x 400 w sodium vapour lighting fixtures similar to


g WFZ68400 of wipro

538
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2 Nos. GI earth plate (Earthing stations) - As per CPWD specifications) with 25
h x 6 mm GI earth strips connecting to highmast.

Aviation obstruction light


I

J Lightning arrestor

High mast as described above


Set 2.00 600,000.00 1,200,000

Ceiling Fan : Supplying of capacitor type1200 mm sweep ceiling fan


complete with blades, shakle etc. with high breeze, high speed for operation
29.00 NON DSR on 230V, 50 Cy. Single phase A.C. supply confirming to IS 374-1979 and with
double ball bearing system The fan shall be green rated as per BEE norms.
Nos 10.00 1,593.00 15,930
Supply, of Exhaust fan 150mm light duty 230 V AC 50 Hz 1400 RPM with
condenser complete erected in position with n/c materials Fan motor with
30.00 NON DSR moisture treatment and class E insulation & With bird protective screen
Nos 10.00 1,346.00 13,460
Supply and fixing of metal fan hook box of 10 mm M.S. round bar , bounded
to to RCC bar up to 50 mm length each side & pierced through a 16 SWG
31.00 NON DSR thick MS bowl 100 mm dia , depth up to 75 mm , complete erected in
position . With one coat of red oxide paint and 2 coats of synthetic paint .
Nos 10.00 301.00 3,010
32.00 NON DSR Exhaust fan of 450mm dia. 900rpm single phase heavy duty.
Nos 2.00 4,000.00 8,000
Exhaust fan of 380mm dia. 900rpm single phase heavy duty.
33.00 NON DSR Nos 5.00 3,000.00 15,000
Supply, installation and fixing of Weather proof IP65 type cast iron junction
box with 2 Nos. earthing terminal to receive 4 x 10sq.mm Aluminum
Armoured cable (2 Nos.) .The scope also includes supply and pulling of
34.00 NON DSR 3Nos. 2.5 sq.mm stranded copper flexible cables from Junction box to
Lighting luminaries with supply ,fixing of 10Amp SP -C-CL,10k.A.MCB , elmex
terminals etc (Minimum size of Junction box is 215 mm x 125 mm x88 mm)
No. 89.00 1,500.00 133,500

Total SH 04- Light and Fans


6,714,555

539
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-05 TELEPHONE SYSTEM

Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
1.00 DSR - 1.53 recessed steel/ PVC conduit as required.
Metre 1,250.00 33.00 41,250

Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
2.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.

DSR - 25mm
a
1.21.2 Metre 700.00 65.00 45,500
DSR - 32mm
b
1.21.3 Metre 300.00 32.00 9,600

Supplying and fixing modular switch/ socket outlet,on the existing modular
3.00 DSR - 1.24 plate & switch box including connections but excluding modular plate etc.
as required.

DSR - Telephone Outlet (RJ-45)


a
1.24.6 Nos. 25.00 95.00 2,375

Laying of PVC insulated armoured 10 Pair with 0.5 mm dia, Tinned copper
Derived conductor Telephone cables including excavation,supply & fiiling of sand
4.00 DSR REF:
and bricks .
7.2.1
Metre 200.00 133.00 26,600

Laying of PVC insulated armoured 50 Pair with 0.5 mm dia, Tinned copper
Derived conductor Telephone cables including excavation,supply & fiiling of sand
5.00 DSR REF: and bricks.
7.2.2
Metre 100.00 141.00 14,100

540
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Laying of PVC insulated armoured 50 Pair with 0.5 mm dia, Tinned copper
Derived conductor Telephone cables in exisitng laid Concealed/Surface conduits,
6.00 DSR REF: cables trays.
7.5.2
Metre 600.00 25.00 15,000
Supply and installation of wall/recessed mounting KRONE connector type
telephone tag block of following sizes in sheet metal enclosure of suitable
dimensions fabricated out of 16 SWG sheet steel with castle key lock,
7.00 Non DSR hinged gasketed type cover including termination of telephone cables,
making connections, painting of box etc, complete as required.

a 10 Pair Tel Tag Block


Nos. 2.00 273.00 546
b 50 Pair Tel Tag Block
Nos. 1.00 1,800.00 1,800
c 100 Pair Tel Tag Block
Nos. 1.00 4,086.00 4,086
d 400 Pair Tel Tag Block
Nos. 2.00 2,500.00 5,000
Supply of following size anealed tinned copper conductor PVC insulated
and sheathed armoured copper telephone cables with suitable clamps,
8.00 Non DSR saddles on existing cable trays / raceways etc and including making terminal
joints complete as required.

a 10 Pair
Metre 200.00 83.00 16,600
b 50 Pair
Metre 100.00 415.00 41,500
c 400 Pair
Metre 600.00 3,260.00 1,956,000
Supply , Erecting & Commissioning of Main Distribution Frame (MDF) box
indoor type with wall mounting facility having front door with lock and
suitable for following capacity along with aluminium frame for mounting
9.00 Non DSR
krone modules. Complete cabinet fabricated from 18SWG CRCA Sheet with
powder coated in approved manner

200x200pairs
a set 1.00 20,929.00 20,929

Total SH 05- Telephone System


2,200,886

541
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-06 FIRE ALARM SYSTEM

Wiring in existing conduit : Supplying and drawing following sizes of FR PVC


insulated copper conductor , single core cable in the existing
1.00 DSR - 1.17
surface/recessed Steel /PVC conduit as required.

DSR - 2 x 1.5 sq.mm


a
1.17.2 Metre 2,675.00 36.00 96,300
DSR - 3 x 1.5 sq.mm
b
1.17.3 Metre 200.00 50.00 10,000

S/F Steel conduit : Supplying and fixing of following sizes of Steel conduits
along with accessories in surface/ recess including painting in case of
2.00 DSR – 1.20 surface conduit,or cutting the wall and making good the same in case of
recessed conduit as required.

DSR –
20mm
a
1.20.1 Metre 200.00 121.00 24,200
25mm
DSR –
b
1.20.2 Metre 2,140.00 142.00 303,880
32 mm
DSR –
c
1.20.3 Metre 193.00
100.00 19,300

Laying of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables including


DerivedDS
3.00 excavation,supply & fiiling of sand and bricks .
R – 7.3.1
Metre 100.00 75.00 7,500

Layingof 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng hume pipes.
Derived
4.00
DSR – 7.5.1
Metre 100.00 15.00 1,500

542
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Laying of of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables on surface
Derived including supply and fixing of G.I. Spacer, saddles etc.
5.00
DSR – 7.7.1
Metre 200.00 25.00 5,000

Laying of 2 Core 1.5 Sq. mm Cu Armoured FRLS cables in exisitng laid


DerivedDS Concealed/Surface conduits, cables trays.
6.00
R – 7.8.1
Metre 2,475.00 25.00 61,875
Supply, Installation, Testing & Commissioning of Analog Addressable type Self
Acclimatising Multi Sensing (Photo+Heat) detector with standard mounting
base, LED, Address Switch, complete with MS Powder coated Junction Box for
7.00 NON -DSR mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends,
cable compression glands, cable tags and Ferruling. (BFC)

Nos 35.00 5,200.00 182,000


Supply, Installation, Testing & Commissioning of Analog addressable Rate of
Rise Cum Fixed temperature detector with standard mounting base, LED,
Address Switch, complete with MS Powder coated Junction Box for mouting
8.00 on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.
Nos 72.00 4,400.00 316,800
9.00 Devices

Supply, Installation, Testing & Commissioning of Addressable Dual Action


Manual Pull Station with Adddress Switch and all mounting accessories ,
9.01 complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 2.00 6,700.00 13,400
Supply, Installation, Testing & Commissioning of Fireman's Phone Jackwith all
mounting accessories, complete with MS Powder coated Junction Box for
9.02 mounting on Surface, Cable Lugs at Ends and all required accesories for
mounting at site complete as requried.
Nos 2.00 5,000.00 10,000

Supply, Installation, Testing & Commissioning of Addressable Module for Fire


Phone Jack with Adddress Switch and all mounting accessories, complete
9.03 with MS Powder coated Junction Box for mouting on Surface, Cable lugs at
Ends, cable compression glands, cable tags and Ferruling.
Nos 2.00 5,800.00 11,600

543
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Addressable Relay Module
with Address Switch and all mounting accessories complete as required.
Shall be complete with Pilot Relay for Tripping of Third Party Equipment,
suitable for switching 5A/15A current through the Relay contacts , MS Powder
9.04 coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.

Nos 10.00 5,800.00 58,000

Supply, Installation, Testing & Commissioning of Addressable Control Module


with Address Switch and all mounting accessories, complete with MS Powder
9.05 coated Junction Box for mouting on Surface, Cable lugs at Ends, cable
compression glands, cable tags and Ferruling.
Nos 4.00 5,800.00 23,200

Supply, Installation, Testing & Commissioning of Directional Sounders with


20Hz to 20 KHz operating frequency with minimum 8 distinct sound patterns
to indicate Exit doors and direct occupants for safe and fast evacuation ,
9.06
complete with MS Powder coated Junction Box for mouting on Surface,
Cable lugs at Ends, cable compression glands, cable tags and Ferruling.
Nos 2.00 21,000.00 42,000

Supply, Installation, Testing & Commissioning of Ceiling / Wall Mounted Muli-


Candela Strobe with all required accessories for mounting complete as
9.07
required.
Nos 2.00 6,800.00 13,600

10.00 Control And Annunciation

544
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Network Control Annunciator
for Fire Command Station with Digital Voice Command Centre with 2 way
Fire Fighters Communication System.

The DVC shall have an Integrated 8 Channel Digital Audio Command Centre
with a capacity to communicate and transmit pre-recorded and paging
messages through the Digital Audio Amplifiers distributed across various floors
of the building on a Digital Audio Loop with zone control function and other
accessories required to complete the system. The System shall have minimum
of 24 Zone Selection Switched.

The Network Control Annunciater and Digital Voice Command Centre shall
be enclosed in the same enclosure and both shall act as independent nodes
10.01 on the true peer to peer network.

The Networked Annunciater shall have minimum 640 character backlit LCD
display with QWERTY keypad, control interface and "soft" and "hard" keys.

The NCA shall have control and display capabilities for all nodes on the
network.

NCA shall be capable to select any zone to relay voice evacution message
from the fire command station.

Voice Command Center shall have a true Network Communication Module


with true peer to peer Connectivity.
Nos 1.00 542,690.00 542,690

Supply, Installation, Testing & Commissioning of Power Supply Unit - 240VAC


to 24VDC - 6Amps. Power Supply shall be UL Listed with Necessary Battery
10.02 Backup.

Nos 1.00 64,700.00 64,700

11.00 Software and Gateways

545
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of Fire Command Station
including Graphical User Interface Software. The GUI based main network
software shall be capable of graphically representing each node being
monitored with floor plans and icons depicting the actual locations of the
various systems; and / or sensors’ locations. The GUI software shall be located
in control room and shall monitor all the blocks panel connected with each
11.01 other. The software shall provide the facility to Monitor, Control all the Digital
Voice Evacuation as well as 2 way communication from main control room
using voice signals over Fire Network along with the Fire detection signal. The
Graphic workstation shall act as an independent node communicating on
the true peer to peer network (failure of any CPU shall not result in failure of
Graphic Workstation).
Nos 1.00 251,300.00 251,300

Supply, Installation, Testing & Commissioning of BACKNET connectivity to


integrate with Building Management System
11.02
Nos 1.00 256,800.00 256,800

Cabling
12.00

Providing, testing and installing / fixing of approved make 20 mm dia.MS


flexible conduits on ceiling / wall / floor etc. complete with accessories like,
12.01 Non DSR Junction boxes, Collars, Bends etc.

metre 300.00 60.00 18,000

Total SH 06- Fire Detection & Alarm System


2,333,645

SH-07 TV System

Supplying and fixing following modular switch/ socket on the existing


modular plate & switch box including connections but excluding modular
1.00 DSR-1.24
plate etc. as required.

TV antenna socket outlet


a DSR-1.24.7
Each 100.00 93.00 9,300

546
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/
recessed steel/ PVC conduit as required.
2.00 DSR - 1.53

Metre 3,500.00 33.00 115,500

Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
3.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.

25mm
DSR -
a
1.21.2
Metre 2,800.00 65.00 182,000

32mm
DSR -
b
1.21.3
Metre 500.00 32.00 16,000

Total SH 07- TV System


322,800

547
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

6 ESTIMATED COST OF ESTIMATE FOR HVAC WORK

HEAD ESTIMATED
S.NO.
AMOUNT IN INR

HIGH SIDE & MISCELLANEOUS


6.01 57,017,856

ACADEMIC BLOCK
6.02 122,406,461

HOSTAL BLOCK
6.03 35,333,192

RESIDENTIAL BLOCK
6.04 5,864,483

TOTAL AMOUNT
220,621,992

548
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATED COST OF EQUPMENT & ELECTRICAL Works FOR HIGH SIDE &
MISSCELLANEOUS

SUBHE SUBHEAD OF WORKS ESTIMATED


AD NO AMOUNT IN INR

PART- A : EQUIPMENT 38,343,404

PART- B : ELECTRICAL WORKS: 21,675,391

TOTAL PART -A & B 60,018,795

LESS 5% FOR UPRNN WORKING (3,000,940)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 57,017,856

549
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

COST ESTIMATE FOR HVAC WORKS

Item Code Description Amount


S.No. Sch Ref. Unit Qty. Rate (Rs.)
No. (Rs.)

I) PART- A : EQUIPMENT

1.0 CHILLERS:

1.1 Supply, installation,Testing and commissioning of Screw Water Chilling Machine


each specified capacityies hereunder, suitable for operation on refrigerant 134a each
comprising of the following complete as per specification and as required. The scope
of work shall also include lifting, shifting and positioning of chiller at location shown
on drawing.

1.1.1 MR HS-AOR:1 Screw Water Chilling Machine each having a capacity of 635040 K.CAL/ Hour ( 210
TR) at chilled water inlet/ outlet temperature of 54 Deg. F (12.22 Deg.C) / 44 Deg. F
(6.67 Deg.C) with chilled water circulation rate of 1905 LPM (nominal) and
condenser water inlet/ outlet temperature of 90 Deg. F (32.22 Deg. C)/ 100 Deg.F
(37.77 Deg. C) with circulation rate 2382 LPM (nominal)

Nos. 1.00 4,303,808.88 4,303,809


Refrigerant - R - 134a

Evaporator Fouling Factor: 0.0005 (British Units)

Condensor Fouling Factor: 0.001 (British Units)

Min. COP = 5.4 at AHRI conditions

Min. IPLV = 6.17 at AHRI conditions

550
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
1.1.2 MR HS-AOR:2 Screw Water Chilling Machine each having a capacity of 907200 K.CAL/ Hour ( 300
TR) chilled water inlet/ outlet temperature of 54 Deg. F (12.22 Deg.C) / 44 Deg. F
(6.67 Deg.C) with chilled water circulation rate of 2722 LPM (nominal) and
condenser water inlet/ outlet temperature of 90 Deg. F (32.22 Deg. C)/ 100 Deg.F
(37.77 Deg. C) with circulation rate 3402 LPM (nominal)

Nos. 4.00 5,782,863.55 23,131,454


Refrigerant - R - 134a

Evaporator Fouling Factor: 0.0005 (British Units)

Condensor Fouling Factor: 0.001 (British Units)

Min. COP = 5.75 at AHRI conditions

Min. IPLV = 6.43 at AHRI conditions

Each Chilling Machine shall comprise

a) 1 No. Screw type compressor open / semi hermatic complete single/multi circuit
with automatic capacity control, safety switches, speed increasing gears, forced feed
lubrication system etc. as per specificaitons.

b) 1 No. Suitable capacity squirrel cage induction motor with class 'F' Insulation suitable
for operation on 415+10% volts, 50Hz, A.C. Supply, (for open type copressor motor
H.P. shall be at least 10% higher than the compressor BHP requirement at full load)

c) 1 No. Star Delta Starter suitable for compressor motor complete with ammeter with
CTs, overload protection, under voltage protection, protection against phase reversal
& independent single phase prevenentions etc. complete as required.

551
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
d) Necessary Drive arrangement

e) 1 Set lubrication device consisting of automatic electric oil pump, oil cooler, head
tank, oil strainer, automatic pressure regulating mechanism, oil heater, thermal
switch etc. as per specificatons.

f) 1 No. matching shell and tube water cooled condenset of M.S. shell and integrally
fined copper tubes.

g) 1 No. matching shell and tube flooed type chiller of M.S. shell and copper tubes.

h) 1 Lot Refrigerant piping fittings, valves and accessories to inter connect compressor,
condenser, chillers and expansion valve.

i) 1 Set Microprocessor based control panel complete with accessories as per


specifications, Controls shall be suitable for hookup to BMS, compatible with
BacNet/ Modbus as per specifications.

j) Lot Refrigerant line accessories comprising of safety valves, angle valves, liquid line
indications, liquid level control etc.

k) Lot - water flow switches at inlet and outlet of condenser and chiller, water drain and
air purge valves wherever required.

l) Lot - Suction line and chiller inuslation with minimum 25 mm thick polyvinyl nitrile
rubber insulation finished with 0.63 mm thick G.S.S. cladding complete as required.

552
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
m) Lot - Frame work for mounting the above condenser, chiller compressor and motor
with base plate complete with antivibration pads/ springs.

n) Lot - Initial/first charge of refrigerant gas and compressor oil.

o) Chiller Plant Optimiser to be provided to operate the chiller plant at part load.

2.0 Chilled Water Pumps:

2.1 Primary Pump:

Supply, installation, testing and commissioning of Chilled Water Primary Pump sets
given hereunder. Minimum pump efficiency shall be 70%. Each pump shall comprise
of following as required as per specifications. The scope of work shall include lifting
& positioning of pump at location shown on drawing.

a) 1 No. End suction/ split casing type pump

b) 1 No. Suitable HP, TEFC squirrel cage induction motor EFF-1 with class 'F' insulations
1450 rpm synchronous speed, operating on 415 + 10% volts, 3 phase, 50 Hz A.C.
supply

c) Lot- Expanded polystrene (T.F. Quality) insulation of not less than 75mm thick duly
cladded with aluminium sheets of 24 G thickness and properly clamped to pump in
two semicircular seciton as per specifications.

d) Lot - Mounting frame work with anti vibration pads.

i) MR HS-AOR:3 1905 LPM at 13m head for 210 TR Screw Chillers (1W+1S)

Nos. 2.00 138,323.80 276,648

553
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ii) MR HS-AOR:4 2722 LPM at 13m head for 300 TR Screw Chillers (3W+1S)

Nos. 4.00 160,292.96 641,172


Note:- Pump head is tentative, contractor had to calculate actual head at the time
of bidding.

2.2 Secondary Pump:


Supply, installation, testing and commissioning of Chilled Water Secondary Pump
set with VFD. Each pump shall comprise of following as required as per
specifications. The scope of work shall include lifting & positioning of pump at
location shown on drawing.

a) 1 No. End suction/ split casing type pump


b) 1 No. Suitable HP, TEFC squirrel cage induction motor EFF-1 with class 'F' insulations
1450 rpm synchronous speed, operating on 415 + 10% volts, 3 phase, 50 Hz A.C.
supply

c) 1 No. dedicated microprocessor based pump controller housed with in the enclosure
of one of the VFDs with pumping software duly downloaded, control and control
wiring etc. complete as required and shall be suitable for operation on 415 + 10%
volts, 50 Hz, 3 Phase AC power supply.

c) Lot- Expanded polystrene (T.F. Quality) insulation of not less than 75mm thick duly
cladded with aluminium sheets of 24 G thickness and properly clamped to pump in
two semicircular seciton as per specifications.

d) Lot - Mounting frame work with anti vibration pads.

i) MR HS-AOR:5 3815 LPM at 28m head for Academic Block (2W+1S)

Set 1.00 1,739,744.98 1,739,745


ii) MR HS-AOR:6 2722 LPM at 28m head for Hostal Block (1W+1S)

Set 1.00 922,478.67 922,479


iii) MR HS-AOR:7 1905 LPM at 28m head for Indoor Stadium Block (1W+1S)
Set 1.00 774,546.42 774,546

554
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Note:- Pump head is tentative, contractor had to calculate actual head at the time
of bidding.

2.3 Condenser Water Pump:

Supply, installation, testing and commissioning of Condenser Water Pump sets given
hereunder comprising of following and complete as per specifications and as
required. The scope of work shall include lifting & positioning of pump at location
shown on drawing.

a) 1 No. End suction/ split casing type pump

b) 1 No. Suitable HP, TEFC squirrel cage induction motor EFF-1 with class 'F' insulations
1450 rpm synchronous speed, operating on 415 + 10% volts, 3 phase, 50 Hz A.C.
supply

c) Lot - Mounting frame work with anti vibration pads.

i) MR HS-AOR:8 2382 LPM at 24m head for 210 TR Screw Chillers (1W+1S)
Nos. 2.00 216,652.93 433,306
ii) MR HS-AOR:9 3402 LPM at 24m head for 300 TR Screw Chillers (3W+1S)
Nos. 4.00 267,471.51 1,069,886
Note:- Pump head is tentative, contractor had to calculate actual head at the time
of bidding.

555
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.0 COOLING TOWERS:

Supply, installation, testing and commissioning of FRP induced draught type cooling
towers of following capacity each complete with FRP basin having and auxiliary
rectangular suction tank at the bottom. The basin shall be complete with
connections for drain, overflow, makeup water, quick fill and float valve, plus hot
dipped galvanised suction strainer FRP body, of sufficient strength to with stand
wind velocities upto 60 m/s, vibrations and earth quakes, fan and motor assembly
conforming to IP-55, protection for outdoor operation fill media of honeycomb
design arranged in the suitable pattern for ease of replacement, distribution pipes
consisting of PVC sprinkler pipes mounted on top of the main supply standby,
sprinkler head mounted on ball bearings designed to take both radial and vertical
thrust overflow pipe, ladder, vibration isolation pads, cables, controls etc. As per
specifications and drawing.

Note:Fans shall operate with VFD & Motor shall be EFF-1 Class

a) MR HS-AOR:10 250 T.R.


Nos. 1.00 552,060.72 552,061
b) MR HS-AOR:11 350 T.R.
Nos. 4.00 705,776.62 2,823,106
4.0 Hot Water Generator:
Providing and installing electrically operated Hot Water Generator of 550 KW
nominal capacity having 1mm thick stainless steel lining with heaters arranged in
banks and controlled by electronic controller and thermostats so that 790LPM hot
O
water at 70 C and with nominal variations could be supplied including 75mm thick
fibre glass / mineral wool / insulation finished with 1.25mm thick G.I. sheet clading
MR HS-AOR:12 including necessary electrical panel board, having suitable incoming & outgoing
switch gears for boiler and pump automatic controls including inlet and outlet
connections for water, foundation for boiler as per specifications complete as
required.

Nos. 2.00 837,596.10 1,675,192

TOTAL CARRIED OVER TO SUMMARY 38,343,404

556
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

II) PART- B : ELECTRICAL WORKS:

MV PANELS:
1.0

Design, fabrication, loading, unloading as directed by Engineer-in-Charge, supply,


installation, testing and commissioning of LT Panels fabricated out of 2mm thick for
structural members (Load bearing members) and 1.6mm thick for door and covers
(Non load bearing members) CRCA sheet in cubicle compartmentalize free standing
floor mounted, dust and vermin proof with reinforcement of suitable size angle iron,
channel 'T' irons and / or flats wherever necessary, 16 gauge CRCA sheet steel shall
be used for final distribution panels. Cable gland plates shall be provided on top as
well as at the bottom of the panels. Panels shall be treated with all anticorrosive
process before painting as per specifications with 2 coats of zinc chromate primer
and final approved shade of enamelled paint. 2 Nos. earthing terminals shall be
provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-
wire, 50Hz supply system and with 15% spare space, lifting hooks shall also be
provided in case of large panels.

Degree of ingress protection of IP 43 for Indoor Installation. Approval shall be taken


for each panel before fabrication. Galvanized hardwares with zinc passivation shall
be used in fabrication of panels.

General Notes:

1 ACB:
LSIG (Microprocessor Based) releases shall be used for incoming feeder .

557
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2 MCCB:

MCCBs of above 250A Microprocessor Based and upto 250A thermal Magnetic
releases.

3 Breaking capacity mentioned is Ics value.

4 This BOQ to be read in conjunction with technical specifications and Single Line
Diagram (attached for reference). If any discrepancy occurs that should be brought
to the notice of Client/Consultant before quoting the price otherwise stringent
condition will be deemed to have been considered.

5 All ACBs to be provided with ON/OFF/Trip lamps, 3 NO + 3NC Auxiliary contacts


other than used in control circuit.

6 All Transformer and DG incoming ACBs shall be provided with Microprocessor based
releases & ON/OFF/Trip / Spring charged/ready to close indicating lamps.

7 All MCCBs shall be provided with rotary operating handle and ON/OFF lamps backed
by 2Amp control MCB.

8 All Starter feeder shall be provided with type - 2 co-ordinated switchgear motor duty
MCCB/MCB, AC-3 Duty Contactor, Over Load Relay with built in single phase
preventor feature, start/stop push button, "Auto/Manual" inbuilt selector switch,
"ON/OFF/TRIP" indicator lamps, Ammeter with CTs, inbuilt selector switch, contactor
contacts for building automation system & interlocking etc. as required. (Type-2
coordination chart to be furnished alon gwith the drawings).

9 All meters shall be digital type (unless otherwise specified)

558
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
10 Multi-function meter to be provided as required to cover all the parameters as
mentioned.

11 All current/voltage transformer shall be cast resin type.

12 All indicating lamps shall be LED type.

13 Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus bar is
after considering all derating factors. (Bus bar sizing calculation to be submitted for
approval.)

14 All internal control wiring shall be heat resistant type.

15 All TP feeders shall be provided with Isolable neutral link.

16 Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry
shall be from top/bottom as required.
-

17 Bus couplers shall be provided with ON & OFF indicating lights but without releases.

18 All feeders shall be provided with door interlocked with door defeat, pad lock
facility.

19 Live parts shall not be accessible after opening the door, Transparent acrylic sheet to
be provided to cover the same.

20 Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto terminal
block.

21 20% spare control terminal to be provided.

559
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
22 All MCCBs shall be provided with variable O/L & S/C releases. Incoming MCCB shall
be provided with E/F releases also

23 All incoming/outgoing cables shall be terminated on links/terminals.

1.1 Air-conditioning Panel

(Loc : A/C Plant room)

Incoming (2 Nos.)

each shall have the following :

630A, 4-pole, 35 KA MCCB with microprocessor based O/L, S/C & E/F releases.

Metering:

(0-500) volts digital voltmeter with inbuilt inbuilt selector switch protected by 2A
control MCB's.

(0-630A) Digital ammeter with inbuilt inbuilt selector switch and suitable ratio, Cl-1,
10VA CT's.

Set of RYB phase indicating lamps with 2A control MCBs.

Bus Coupler (1 No.)

630A, 4-pole, MCCB (35kA) with ON/OFF indication lamps.

Key interlocking shall be provided between incomers.

Busbar

560
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
800A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz (after
derating).

Outgoing:
- Seventeen (17) Nos. 32A FP MCCB (25kA)
- Four (4) Nos. 100A FP MCCB (25kA)
- Seven (7) Nos. 63A FP MCCB (25kA)

Two (2) Nos. auto DOL Starter of 10 HP with single phasing prevention arrangement,
O/L relays, ammeters with CTs, ON/OFF/Trip indication lamps and push buttons,
potential free contacts for remote operation in each feeder complete as required
(for Primary Chilled Water Pumps) ( 1W+1S)

Four (4) Nos. auto Star-Delta Starter of 16 HP with single phasing prevention
arrangement, O/L relays, ammeters with CTs, ON/OFF/Trip indication lamps and
push buttons, potential free contacts for remote operation in each feeder complete
as required (for Primary Chilled Water Pumps) (3W +1S)

Three (3) Nos. auto Star-Delta Starter of 40 HP with single phasing prevention
arrangement, O/L relays, ammeters with CTs, ON/OFF/Trip indication lamps and
push buttons, potential free contacts for remote operation in each feeder complete
as required (for Secondary Chilled Water Pumps) (2W+1S)

Two (2) Nos. auto Star-Delta Starter of 25 HP with single phasing prevention
arrangement, O/L relays, ammeters with CTs, ON/OFF/Trip indication lamps and
push buttons, potential free contacts for remote operation in each feeder complete
as required (for Secondary Chilled Water Pumps) (1W+1S)

561
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Two (2) Nos. auto Star-Delta Starter of 20 HP with single phasing prevention
arrangement, O/L relays, ammeters with CTs, ON/OFF/Trip indication lamps and
push buttons, potential free contacts for remote operation in each feeder complete
as required (for Secondary Chilled Water Pumps) (1W+1S)

Two (2) Nos. auto Star-Delta Starter of 20 HP with single phasing prevention
arrangement, O/L relays, ammeters with CTs, ON/OFF/Trip indication lamps and
push buttons, potential free contacts for remote operation in each feeder complete
as required (for Condenser Water Pumps) (1W+1S)

Four (4) Nos. auto Star-Delta Starter of 25 HP with single phasing prevention
arrangement, O/L relays, ammeters with CTs, ON/OFF/Trip indication lamps and
push buttons, potential free contacts for remote operation in each feeder complete
MR HS-AOR:13
as required (for Condenser Water Pumps) (3W+1S)

Set 1.00 1,079,200.00 1,079,200


2.0 Isolators:
Supply & fixing, testing and commissioning of Lockable isolator box in powder
coated MS enclosure suitable for wall mounting and floor mounting with provisions
of incoming and outgoing cables. The protection class of the Isolator Box shall be IP-
55 & the rating should be as follows:

25 Amp 4Pole
a) MR HS-AOR:13
Nos. 5.00 3,000.00 15,000
63 Amp 4Pole
b) MR HS-AOR:13
Nos. 60.00 3,000.00 180,000
100 Amp 4Pole
c) MR HS-AOR:13
Nos. 15.00 15,100.00 226,500
32 Amp 4Pole
d) MR HS-AOR:13
Nos. 25.00 3,000.00 75,000

562
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.1 Main AHU Panel

(Loc : Academic Block)

Incoming
each shall have the following :

- 400A, 4-pole, 25 KA MCCB

Metering:
(0-500) volts digital voltmeter .

(0-400A) Digital ammeter.

Set of RYB phase indicating lamps with 2A control MCBs.

Busbar

500A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz (after
derating).

Outgoing:
- One (1) No. 200A MCCB
- Two (2) No. 125A MCCB
- Five (5) No. 100A MCCB
MR HS-AOR:14 Set 1.00 241,600.00 241,600

3.2 AHU MDB


(Loc : Gournd Floor)

563
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Incoming
each shall have the following :

- 315A, 4-pole, 25 KA MCCB

Metering:
(0-500) volts digital voltmeter .

(0-300A) Digital ammeter.

Set of RYB phase indicating lamps with 2A control MCBs.

Busbar
400A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz (after
derating).

Outgoing:

- Twenty (20) No. 20A MPCB

- Two (2) No. 25A MPCB

- Five (5) No. 40A MPCB


MR HS-AOR:14 Set 1.00 247,900.00 247,900

3.3 AHU MDB


(Loc : First Floor)

Incoming

each shall have the following :

100A, 4-pole, 25 KA MCCB

564
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Metering:

(0-500) volts digital voltmeter .

(0-100A) Digital ammeter.

Set of RYB phase indicating lamps with 2A control MCBs.

Busbar

160A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz (after
derating).

Outgoing:
- Seventeen (17) No. 20A MPCB
MR HS-AOR:14 Set 1.00 161,700.00 161,700
3.4 AHU MDB For second & third floor
(Loc : Second Floor)
Incoming

each shall have the following :

100A, 4-pole, 25 KA MCCB


Metering:

(0-500) volts digital voltmeter.

(0-100A) Digital ammeter.


Set of RYB phase indicating lamps with 2A control MCBs.
Busbar

160A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz (after
derating).

Outgoing:
- Eleven (11) No. 20A MPCB
MR HS-AOR:14 Set 1.00 122,100.00 122,100

565
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.5 AHU MDB (For 4th, 5th & 6th)

(Loc : 4th Floor)

Incoming

each shall have the following :

160A, 4-pole, 25 KA MCCB.

Metering:

(0-500) volts digital voltmeter .

(0-160A) Digital ammeter.


Set of RYB phase indicating lamps with 2A control MCBs.
Busbar

200A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz (after
derating).
Outgoing:

- Nineteen (19) No. 20A MPCB


MR HS-AOR:14 Set 1.00 175,700.00 175,700

3.6 AHU MDB


(Loc : Indoor Stadium)
Incoming
each shall have the following :
100A, 4-pole, 25 KA MCCB.

Metering:

(0-500) volts digital voltmeter.

(0-100A) Digital ammeter.

Set of RYB phase indicating lamps with 2A control MCBs.

566
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Busbar

160A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz (after
derating).

Outgoing:

- Eleven (11) No. 20A MPCB


MR HS-AOR:14 Set 1.00 122,100.00 122,100

3.7 AHU MDB


(Loc : Hostel)

Incoming

each shall have the following :

- 100A, 4-pole, 25 KA MCCB.

Metering:

(0-500) volts digital voltmeter.

(0-100A) Digital ammeter.

Set of RYB phase indicating lamps with 2A control MCBs.

Busbar

160A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz (after
derating).

567
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Outgoing:

- Forty (40) No. 16A MPCB


MR HS-AOR:14 Set 1.00 293,000.00 293,000

3.8 Ventilation Panel (MDB) (Basement)


(Loc : Academic Block - Exhaust Air)
Incoming (1 No.) :

- 800A, FP MCCB (35KA)

Metering & Indication:

(0-500) volts digital voltmeter.

(0-800A)Digital ammeter.

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:

1000A, TPN aluminium , colour coded bus bars suitable for 415V, 50Hz. (after
deration)

Outgoings:
- Thirty Eight (38) Nos. 63A 4P MCCB (25KA)

- Twelve (12) nos. Auto Star Delta starter of 20.0 HP with 63 A TP Contactor, overload
relay having single phasing prevention feature (Voltage Base), Ammeter with
suitable CTs, inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop
push buttons, suitable for remote operation & interlocking in each feeders required.

- Twenty Four (24) nos. Auto Star Delta starter of 15.0 HP with 63 A TP Contactor,
overload relay having single phasing prevention feature (Voltage Base), Ammeter
with suitable CTs, inbuilt selector switches, ON/OFF/ TRIP indication lamps and
Start/Stop push buttons, suitable for remote operation & interlocking in each
MR HS-AOR:15 feeders required. Set 1.00 1,643,300.00 1,643,300

568
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

3.9 Ventilation Panel (MDB) (Basement)

(Loc : Academic Block - Supply Air)

Incoming (1 No.) :
- 800A, FP MCCB (35KA)

Metering & Indication:


(0-500) volts digital voltmeter.

(0-800A)Digital ammeter.

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:
1000A, TPN aluminium , colour coded bus bars suitable for 415V, 50Hz. (after
deration)

- Outgoings:
Thirty Two (32) Nos. 63A 4P MCCB (25KA)

- Ten (10) nos. Auto Star Delta starter of 20.0 HP with 63 A TP Contactor, overload
relay having single phasing prevention feature (Voltage Base), Ammeter with
suitable CTs, inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop
push buttons, suitable for remote operation & interlocking in each feeders required.

- Twenty (20) nos. Auto Star Delta starter of 15.0 HP with 63 A TP Contactor, overload
relay having single phasing prevention feature (Voltage Base), Ammeter with
suitable CTs, inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop
push buttons, suitable for remote operation & interlocking in each feeders required.

MR HS-AOR:15 Set 1.00 1,356,000.00 1,356,000

3.10 Ventilation Panel (MDB)


(Loc : Academic Block - Toilet Exhaust)

569
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Incoming (1 No.) :
- 100A, FP MCCB (25KA)

Metering & Indication:


(0-500) volts digital voltmeter.

(0-100A)Digital ammeter.

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:
160A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz. (after
deration)

Outgoings:
- Three (3) Nos. 25A 4P MCB (25KA)
- Six (6) Nos. 10A 4P MCB (10KA)

- One (1) nos. Auto DOL starter of 1.5 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- One (1) nos. Auto DOL starter of 1.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Two (2) nos. Auto DOL starter of 10.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

570
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
- Two (2) nos. Auto DOL starter of 0.5 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

MR HS-AOR:15 Set 1.00 152,800.00 152,800

3.11 Fan MDB

(Loc : Academic Block)

Incoming (1 No.) :
- 200A, FP MCCB (25KA)

Metering & Indication:


(0-500) volts digital voltmeter with inbuilt selector switch protected by 2A control
MCB's.

(0-200A)Digital ammeter with inbuilt selector switch and suitable ratio, Cl-1, 10VA
CT's.

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:
200A, TPN aluminium , colour coded bus bars suitable for 415V, 50Hz. (after
deration)

Outgoings:

- Twenty Five (25) Nos. 25A 4P MCB (25KA)

571
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
- Five (5) nos. Auto DOL starter of 5.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Ten (10) nos. Auto DOL starter of 7.5 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Two (2) nos. Auto DOL starter of 10.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Three (3) nos. Auto DOL starter of 2.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Two (2) nos. Auto DOL starter of 3.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.
MR HS-AOR:15 Set 1.00 421,800.00 421,800

3.12 Ventilation Panel


(Loc : Academic Block - Ground Floor)

Incoming (1 No.) :
- 100A, 4P MCCB (25KA)

572
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Metering & Indication:
(0-500) volts digital voltmeter.

(0-100A)Digital ammeter.

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:
160A, TPN aluminium, colour coded busbars suitable for 415V, 50Hz. (after deration)

Outgoings:
- Thirty (30) Nos. 25A 4P MCB (15KA)

- Four (4) nos. Auto DOL starter of 0.5 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Two (2) nos. Auto DOL starter of 2.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Twelve (12) nos. Auto DOL starter of 3.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

573
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
- Eight (8) nos. Auto DOL starter of 7.5 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- One (1) nos. Auto Star Delta starter of 15 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

HS-AOR:16 Set 1.00 502,600.00 502,600

3.13 Ventilation Panel

(Loc : First Floor)

Incoming (1 No.) :

- 200A, 4P MCCB (25KA)

Metering & Indication:


(0-500) volts digital voltmeter.

(0-200A)Digital ammeter.

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:

300A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz. (after
deration)

574
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Outgoings:
- Twenty Seven (27) Nos. 25A 4P MCB (15KA)

- Three (3) nos. Auto DOL starter of 1.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Two (2) nos. Auto Star Delta starter of 15 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- One (1) nos. Auto DOL starter of 1.5 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Two (2) nos. Auto DOL starter of 2.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Four (4) nos. Auto DOL starter of 3.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

575
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
- Three (3) nos. Auto DOL starter of 5.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Eight (8) nos. Auto DOL starter of 7.5 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

MR HS-AOR:16 Set 1.00 465,800.00 465,800

3.14 Ventilation Panel (MDB)


(Loc : Hostel Block)

Incoming (1 No.) :
- 315A, 4P MCCB (25KA)

Metering & Indication:


(0-500) volts digital voltmeter.

(0-300A)Digital ammeter.

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:

400A, TPN aluminium, colour coded busbars suitable for 415V, 50Hz. (after deration)

Outgoings:

- Three (3) Nos. 25A 4P MCB (15KA)

576
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
- Ten (10) Nos. 63A 4P MCB (15KA)

- Two (2) nos. Auto DOL starter of 7.5 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Three (3) nos. Auto Star Delta starter of 25 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Six (6) nos. Auto Star Delta starter of 20HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

MR HS-AOR:16 Set 1.00 334,900.00 334,900

3.15 Ventilation Panel


(Loc : Indoor Stadium)

Incoming (1 No.) :
- 160A, 4P MCCB (25KA)

Metering & Indication:


(0-500) volts digital voltmeter.

(0-160A)Digital ammeter.

577
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:
200A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz. (after
deration)

Outgoings:
- Ten (10) Nos. 16A 4P MCB (15KA)
- Four (4) Nos. 63A 4P MCB (15KA)

- Three (3) nos. Auto Star Delta starter of 20HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- Three (3) nos. Auto DOL starter of 5.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- One (1) nos. Auto DOL starter of 2.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.

- MR HS-AOR:16 Four (4) nos. Auto DOL starter of 1.0 HP with 63 A TP Contactor, overload relay
having single phasing prevention feature (Voltage Base), Ammeter with suitable CTs,
inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop push
buttons, suitable for remote operation & interlocking in each feeders required.
Set 1.00 272,000.00 272,000

578
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.16 Ventilation Panel

(Loc : Residential)

Incoming (1 No.) :

- 200A, 4P MCCB (25KA)

Metering & Indication:


(0-500) volts digital voltmeter.

(0-200A)Digital ammeter.

Set of Phase indicating lamps. Each backed up with 2 Amps Control MCB.

Bus Bars:
300A, TPN aluminium, colour coded bus bars suitable for 415V, 50Hz. (after
deration)

Outgoings:

- Three (3) Nos. 25A 4P MCB (15KA)

- Seven (7) Nos. 63A 4P MCB (15KA)

- Three (3) nos. Auto Star Delta starter of 20.0 HP with 63 A TP Contactor, overload
relay having single phasing prevention feature (Voltage Base), Ammeter with
suitable CTs, inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop
push buttons, suitable for remote operation & interlocking in each feeders required.

579
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
- Four (4) nos. Auto Star Delta starter of 12.50 HP with 63 A TP Contactor, overload
relay having single phasing prevention feature (Voltage Base), Ammeter with
suitable CTs, inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop
push buttons, suitable for remote operation & interlocking in each feeders required.

- Two (2) nos. Auto Star Delta starter of 15.0 HP with 63 A TP Contactor, overload
relay having single phasing prevention feature (Voltage Base), Ammeter with
suitable CTs, inbuilt selector switches, ON/OFF/ TRIP indication lamps and Start/Stop
push buttons, suitable for remote operation & interlocking in each feeders required.

MR HS-AOR:16 Set 1.00 313,400.00 313,400

4.0 Starter Panel for AHUs

Supply, Installation, Testing and Commissioning Starter Panel of 3.7/ 2.2/ 7.5/ 1.1/
11/ 1.5/ 5.5/ 0.75 KW (DOL) having provision of two outgoing of suitable rating
interlocking in the outgoing feeder one for AHU and another for VFD Starter.

MR HS-AOR:16 No. 131.00 31,000.00 4,061,000

5.0 DISTRIBUTION BOARDS:

Supply, installation, testing & commissioning of following MCB type horizontal


Double Door Distribution boards as per drawing & specification fabricated out of 16
SWG CRCA sheet steel in compartmentalized design double door (IP 43) as per
specification and drawings these distribution boards shall be surface/ recessed in
walls. The rate includes the painting, numbering earthing, blanking plate etc. as
required.

a) 8 Way TPN DB (Customised/Fabricated)


Comprising of following:

Incoming:
- One (1) No. 63A FP MCB (10 KA)

580
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
- Three (3) Nos. 32A DP ELCB (100mA)

Outgoing:
Twenty(24) Nos. 6 to 25A SP MCB (10KA)

Busbar:
60A Copper bus bar

Neutral link:
Separate

Earthing:
MR Suitable for 18 Nos. outgoings. Nos. 5.00 15,000.00 75,000

b) 8 Way VTPN DB (Customised/Fabricated)


Comprising of following:

Incoming:
- One (1) No. 63A FP MCB (10 KA)

Outgoing:
Eight(8) Nos. 20A FP MCB
Twelve (12) Nos. 16A SP MCB
Four (4) Nos. 10A SP MCB

Busbar:
100A Copper bus bar

Neutral link:
Separate

Earthing:
MR Suitable for 6 Nos. outgoings. Nos. 5.00 25,000.00 125,000

6.0 M.V. Cables

581
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.1 Supply and laying of following sizes of XLPE insulated PVC sheathed, Aluminum
conductor armoured power cable of 1.1 KV grade conforming to latest IS amended
upto date.

Guaranteed Technical Particulars for 1.1kV Cables

Conductor :
Core/Size : 3.5/4
Material : Aluminum
Shape : Circular
Type : Stranded

Insulation :

Material : XLPE

Inner Sheath:

Material : PVC(ST1/ST2)

Type : Extruded

Armoured:

Material : GI

Type : Flat

Outer Sheath:
Material : PVC/XLPE
Drum Length : As per Site requirement

582
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.5C x 300 Sqmm
a) RM
MR HS-AOR:17 300.00 1,265.00 379,500
3.5C x 240 Sqmm
b) RM
MR HS-AOR:17 200.00 1,055.00 211,000
3.5C x 185 Sqmm
c) RM
MR HS-AOR:17 600.00 835.00 501,000
3.5C x 150 Sqmm
d) RM
MR HS-AOR:17 800.00 690.00 552,000
3.5C x 120 Sqmm
e) RM
MR HS-AOR:17 1,000.00 595.00 595,000
3.5C x 95 Sqmm
f) RM
MR HS-AOR:17 200.00 475.00 95,000
3.5C x 70 Sqmm
g) RM
MR HS-AOR:17 100.00 390.00 39,000
3.5C x 50 Sqmm
h) RM
MR HS-AOR:17 600.00 240.00 144,000
3.5C x 35 Sqmm
i) RM
MR HS-AOR:17 300.00 237.82 71,346
4C x 25 Sqmm
j) RM
MR HS-AOR:17 3,000.00 213.45 640,364
4C x 16 Sqmm
k) RM
MR HS-AOR:17 1,500.00 167.31 250,971
4C x 10 Sqmm
l) RM
MR HS-AOR:18 2,500.00 160.00 400,000
4C x 6 Sqmm
m) RM
MR HS-AOR:18 1,500.00 115.00 172,500
4C x 4 Sqmm
n) RM
MR HS-AOR:18 1,000.00 105.00 105,000

583
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2C x 10 Sqmm
o) RM
MR HS-AOR:18 1,000.00 105.00 105,000
2C x 6 Sqmm
p) RM
MR HS-AOR:18 100.00 90.00 9,000
2C x 4 Sqmm
q) RM
MR HS-AOR:18 100.00 85.00 8,500
3C x 25 Sqmm
r) RM
MR HS-AOR:19 500.00 185.00 92,500
3C x16 Sqmm
s) RM
MR HS-AOR:19 1,900.00 150.00 285,000
3C x 10 Sqmm
t) RM
MR HS-AOR:19 2,800.00 140.00 392,000

6.2 Cable Termination :

Supplying of all materials and making terminations of 1.1 KV grade aluminium


multicore cables of the following sizes. The work includes cable glanding using brass
plated double compression glands, sizing the core leads, removing insulation, fixing
suitable crimping type aluminium lugs/thimbles by using hydraulic crimping tools
with correct size of the dies, shaping the leads and neatly connecting the same to the
equipment terminals.

a) DSR 9.1.30 3.5C x 300 Sqmm Sets 10.00 1,086.00 10,860


b) DSR 9.1.29 3.5C x 240 Sqmm Sets 10.00 969.00 9,690
c) DSR 9.1.27 3.5C x 185 Sqmm Sets 14.00 784.00 10,976
d) DSR 9.1.26 3.5C x 150 Sqmm Sets 10.00 576.00 5,760
e) DSR 9.1.25 3.5C x 120 Sqmm Sets 10.00 484.00 4,840
f) DSR 9.1.24 3.5C x 95 Sqmm Sets 6.00 466.00 2,796
g) DSR 9.1.23 3.5C x 70 Sqmm Sets 6.00 382.00 2,292

584
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
h) DSR 3.5C x 50 Sqmm Sets 16.00
9.1.22 342.00 5,472
i) DSR 9.1.21 3.5C x 35 Sqmm Sets 18.00 270.00 4,860
j) DSR 9.1.34 4C x 25 Sqmm Sets 24.00 248.00 5,952
k) DSR 9.1.33 4C x 16 Sqmm Sets 26.00 245.00 6,370
l) DSR 9.1.32 4C x 10 Sqmm Sets 12.00 193.00 2,316
m) DSR 9.1.2 2C x 10 Sqmm Sets 16.00 365.00 5,840
n) DSR 9.1.1 2C x 6 Sqmm Sets 6.00 302.00 1,812
o) DSR 9.1.9 3C x 25 Sqmm Sets 12.00 195.00 2,340
p) DSR 9.1.8 3C x16 Sqmm Sets 24.00 192.00 4,608
q) DSR 9.1.7 3C x 10 Sqmm Sets 24.00 161.00 3,864
r) MR 4C x 6 Sqmm Sets 12.00 125.00 1,500
s) MR 4C x 4 Sqmm Sets 26.00 125.00 3,250
t) MR 2C x 4 Sqmm Sets 6.00 302.00 1,812

7.0 Control Cables:

7.1 Supplying amd laying of the following sizes of 1.1 KV grade PVC insulated & PVC
sheathed copper conductor armoured stranded control cable conforming latest IS
complete as required. (The rate shall including termination also)

a) MR HS-AOR:19 2 Core x 2.5 Sq.mm Cable


RM 500.00
115.00 57,500
b) MR HS-AOR:19 4 Core x 2.5 Sq.mm Cable
RM 200.00
170.00 34,000
c) MR HS-AOR:19 7 Core x 2.5 Sq.mm Cable
RM 100.00
255.00 25,500
d) MR HS-AOR:19 10 Core x 2.5 Sq.mm Cable
RM 100.00
320.00 32,000
e) MR HS-AOR:19 12 Core x 2.5 Sq.mm Cable
RM 100.00
360.00 36,000

585
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.0 Cable Trays :

Supply, fabricating and installing following size of perforated M.S. cable trays
including horizontal and vertical bends, reducers, tees, cross members and other
accessories as required, and duly suspended from the ceiling with M.S. suspenders,
including painting etc.

a) 40 x 600 x 40 x 2 mm thick
MR RM 300.00 1,022.00 306,600
b) 40 x 450 x 40 x 2 mm thick
MR RM 800.00 999.00 799,200
c) 40 x 300 x 40 x 2 mm thick
MR RM 2,000.00 890.00 1,780,000
d) 40 x 150 x 40 x 2 mm thick
MR RM 600.00 352.00 211,200

8.1 Cable Tray Support

Supplying and fixing of MS rod/angle hangers duly painted with 2 coats of spray
paint for supporting the cable trays, complete for extension of the supports.
MT 40.00 65.00 2,600

9.0 Hume Pipes:

9.1 Providing non-pressure NP-2 Class (light duty) RCC pipe with collars jointed with stiff
mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 Find Sand) including
testing of joints etc. complete.

a) 150 mm dia
MR RM 200.00 550.00 110,000
b) 300 mm dia
MR RM 250.00 650.00 162,500

586
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
10.0 EARTHING STATION:

Providing and laying of 600 x 600 x 6 mm GI plate with 2 nos. 50 x 6 mm GI tape form
earth electrode to inspection chamber, 20 mm dia medium class GI pipe, CI funnel
with 20 gauge GI wire mesh, masonry chamber 300x300 mm with concrete base CI
manhole cover having locking arrangement with frame painted with bitumastic paint
& packing with mixtures of charcoal & common salt around plate electrode including
digging of pit upto permanent moisture level but not less than 3 meter & back filling
as required.

MR Nos. 4.00 9,000.00 36,000

11.0 EARTHING STRIP/WIRES:

G.I. Earthing Strip/Wire:

Supply, installation, testing & commissioning of following sizes of GI strip/wire


clamped to walls, cable trays, bus ducts, cables, in recess (including cost of digging &
backfilling) or on surface etc. for equipment/ System / Lightning protection earthing
complete as required including inter connection between length at joints, all fixing
accessories saddles, clamps, test joints etc. and other fixing hardware material as
required for proper installation.

GI Earthing Strip/Wire:

a) 50 x 6 mm strip
MR RM 100.00 225.00 22,500
b) 32 x 6 mm strip
MR RM 450.00 180.00 81,000
c) 25 x 6 mm strip
MR RM 350.00 150.00 52,500
d) 25 x 3 mm strip
MR RM 300.00 140.00 42,000
e) 8 SWG Wire
MR RM 5,000.00 15.00 75,000

TOTAL CARRIED OVER TO SUMMARY


21,675,391

587
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATE COST OF HVAC WORKS OF ACADEMIC BLOCK

SUBEAD SUBHEAD OF WORKS ESTIMATED


NO AMOUNT IN INR

PART- A : AIR CIRCULATION SYSTEM:


I) 15,449,912

PART- B : PIPING:
II) 17,184,722

III) PART- C : MECHANICAL VENTILATION WORK: 46,587,858

PART- D : AIR DISTRIBUTION SYSTEM


IV) 49,626,415

TOTAL AMOUNT 128,848,907

LESS 5% FOR UPRNN WORKING (6,442,445)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 122,406,461

588
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

1.0 PREAMBLE TO BOQ:

1.1 Tendered Rates all Inclusive:

1.1.1 Unless otherwise provided in the Bill of Quantities, the rates tendered
by the Contractor for all items of the work shall be all inclusive and
shall apply to all heights, lifts, leads and depths, in all positions of the
building.

1.1.2 Rates/prices quoted in this tender shall be inclusive of cost of


materials, labours, supervision, installation, testing and commissioning,
materials erection, tools, plant appliances, scaffolding, sleeves,
cutting, patching, excavation and backfilling, painting, storage of
material, service connections, transport to site, taxes, duties, transit
insurance octroi and levies, all relevant insurance charges, breakage,
wastage and all such expenses as may be necessary and required for
the satisfactory completion of all the items of the work and final
guarantee testing and to put there in working conditions and all other
requirements as called for in all the parts of these Tender Documents.

1.1.3 All rates quoted must be for complete items inclusive of all such
accessories, fixtures and fixing arrangements, supports, nuts, bolts,
hangers as are a standard part of the particular item except where
specially mentioned otherwise.

1.1.4 All rates quoted are inclusive of cutting holes and chases in walls and
making good the same with cement mortar / concrete / water
proofing of appropriate mix and strength. Rates are inclusive of holes,
sleeves, recesses in the concrete and masonry work as the Work
proceeds except foundation work.

589
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
1.1.5 All rates quoted shall include marking of grills/diffusers.

1.1.6 Nothing extra shall be payable to Contractor on account of any of the


above factors.

1.1.7 The client reserves the right to supply directly any of the items listed in
the BOQ. For all such items, if desired by the Owner, installation, testing
and commissioning shall be the responsibility of the Contractor.

I) PART- A : AIR CIRCULATION SYSTEM:


1.0 AIR HANDLING UNIT:
1.1 FLOOR MOUNTED:

Supply, Installation, Testing and commissioning of factory built floor


mounted chilled water double skin type horizontal/vertical air
handling units made of 25mm thick panels consisting of pre plasticized
G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer
with polyurethane foam (PUF) insulation factory injected between
them by injection moulding machine, complete with blower section
with blower suitable for static pressure as required, minimum 2 bend
GSS/PVC eliminators,cooling coil section with aluminium finned
copper tubes (tubes thickness not less than 0.5mm) cooling coil of 4/6
row deep, filter section with 50mm thick metal viscous/ washable
synthetic type air prefilters, belt drive package with TEFC drive EFF-1
motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain
connections, stainless steel (18G) drain pan with PUF insulation, 150
mm dia. dial type pressure gauges (2 nos.)and industrial type
thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve
wherever required, mixing box wherever required, necessary vibration
isolation arrangement etc. complete as per specification and of
following capacities. Noise level is from each ahu at 1 mtr distance
shall not exceed 65 dB.

590
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Ground Floor

ADMIN- Horizontal AHU: 3700 CFM at 50 mm static pressure. (10.09 T.R.), (C. FOR
a) MR AOR:1 GOOD GOVER. T. HALL) T. TH 101
No. 1.00 110,220.67 110,221
ADMIN- Horizontal AHU: 3700 CFM at 50 mm static pressure. (10.09 T.R.), (DIS.
b) MR AOR:1 MAN. CELL T. HALL) T. TH 102
No. 1.00 110,220.67 110,221
ADMIN- Horizontal AHU: 7400 CFM at 50 mm static pressure. (23.17 T.R.),
c) MR AOR:1 (MULTIPUPOSE HALL) MH 101
No. 1.00 161,111.41 161,111
ADMIN- Horizontal AHU: 6900 CFM at 50 mm static pressure. (18.05 T.R.), (C.
d) MR AOR:1 ROOM (CAP 70 to 80) LH 101
No. 1.00 158,879.36 158,879
ADMIN- Horizontall AHU: 3800 CFM at 50 mm static pressure. (11.03 T.R.), (C.
e) MR AOR:1 ROOM (CAP 50 to 60) LH 104
No. 1.00 111,113.49 111,113
ADMIN- Horizontall AHU:3800 CFM at 50 mm static pressure. (11.03 T.R.), (C.
f) MR AOR:1 ROOM (CAP 50 to 60) LH 105
No. 1.00 111,113.49 111,113
ADMIN- Horizontall AHU: 4100 CFM at 50 mm static pressure. (10.80 T.R.),
g) MR AOR:1 (CONFERENCE HALL 01) CR 101
No. 1.00 114,982.38 114,982
ADMIN- Horizontall AHU: 4100 CFM at 50 mm static pressure. (10.80 T.R.),
h) MR AOR:1 (CONFERENCE HALL 02) CR 102
No. 1.00 114,982.38 114,982
ADMIN- Horizontall AHU: 16600 CFM at 50 mm static pressure. (45.43 T.R.),
i) MR AOR:1 (AUDITORIUM (D. HT.) AD 301
No. 1.00 324,199.87 324,200
ADMIN- Horizontall AHU: 4900 CFM at 50 mm static pressure. (12.95 T.R.), (C.
j) MR AOR:1 ROOM (CAP 50 to 60)) LH 102
No. 1.00 136,261.26 136,261
ADMIN- Horizontall AHU: 4900 CFM at 50 mm static pressure. (12.95 T.R.), (C.
k) MR AOR:1 ROOM (CAP 50 to 60)) LH 103
No. 1.00 136,261.26 136,261
ADMIN- Horizontall AHU: 3500 CFM at 50 mm static pressure. (9.08 T.R.),
l) MR AOR:1 (COURSE COORDINATORS) CC 101
No. 1.00 103,375.72 103,376
ADMIN- Horizontall AHU: 2200 CFM at 50 mm static pressure. (6.67 T.R.), C.
m) MR AOR:1 ROOM (CAP 30 to 40) LH 106
No. 1.00 82,394.45 82,394

591
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ADMIN- Horizontall AHU: 2200 CFM at 50 mm static pressure. (6.67T.R.), C.
n) MR AOR:2 ROOM (CAP 30 to 40) LH 107
No. 1.00 82,394.45 82,394
ADMIN- Horizontall AHU: 2200 CFM at 50 mm static pressure. (6.67T.R.), C.
o) MR AOR:2 ROOM (CAP 30 to 40) LH 108
No. 1.00 82,394.45 82,394
ADMIN- Horizontall AHU: 2200 CFM at 50 mm static pressure. (6.67 T.R.), C.
p) MR AOR:2 ROOM (CAP 30 to 40) LH 109
No. 1.00 82,394.45 82,394
ADMIN- Horizontall AHU: 3200 CFM at 50 mm static pressure. (7.53 T.R.),
q) MR AOR:2 (COURSE COORDINATORS) CC 102
No. 1.00 13,647.31 13,647
ADMIN- Horizontall AHU: 1600 CFM at 50 mm static pressure. (3.93 T.R.),
r) MR AOR:2 (LOUNGE 1) LG 102
No. 1.00 66,174.88 66,175
ADMIN- Horizontall AHU: 1600 CFM at 50 mm static pressure. (3.93 T.R.),
s) MR AOR:2 (LOUNGE 2) LG 104
No. 1.00 66,174.88 66,175
ADMIN- Horizontall AHU: 1900 CFM at 50 mm static pressure. (4.35 T.R.),
t) MR AOR:2 (LOUNGE 3) LG 101
No. 1.00 69,746.17 69,746
ADMIN- Horizontall AHU: 1900 CFM at 50 mm static pressure. (4.35 T.R.),
u) MR AOR:2 (LOUNGE 4) LG 103
No. 1.00 69,746.17 69,746
ADMIN- Horizontall AHU: 19000 CFM at 50 mm static pressure. (38.00 T.R.),
v) MR AOR:2 (LOUNGE 4) LG 103
No. 4.00 376,578.65 1,506,315
-
FIRST FLOOR
-
a) ADMIN- Horizontall AHU: 4900 CFM at 50 mm static pressure. (14.09 T.R.), (M.
MR AOR:3 DEV. CELL T. HALL TH 201 )
No. 1.00 136,261.26 136,261
b) ADMIN- Horizontall AHU:5000 CFM at 50 mm static pressure. (16.17 T.R.), (A.V.
MR AOR:3 LAB LY 201D)
No. 1.00 136,112.45 136,112
c) ADMIN- Horizontall AHU: 3500 CFM at 50 mm static pressure. (8.49 T.R.), (A.V.
MR AOR:3 LAB (40 CAPACITY) AV 201 )
No. 1.00 106,351.79 106,352

592
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
d) ADMIN- Horizontall AHU: 1600 CFM at 50 mm static pressure. (3.80 T.R.), (I.T. W.
MR AOR:3 S. OFFICE IT 201A)
No. 1.00 66,174.88 66,175
e) ADMIN- Horizontall AHU: 3500 CFM at 50 mm static pressure. (8.28 T.R.), (BOARD
MR AOR:3 ROOM BD 201)
No. 1.00 106,351.79 106,352
ADMIN- Horizontall AHU: 3100 CFM at 50 mm static pressure. (7.37 T.R.), (BOARD
f) MR AOR:3 ROOM LOUNGE BD 201B & VIP WAITING BD 201A)
No. 1.00 99,804.44 99,804
g) ADMIN- Horizontall AHU: 8000 CFM at 50 mm static pressure. (18.21 T.R.),
MR AOR:3 (READING AREA LY 201B)
No. 1.00 163,194.66 163,195
h) ADMIN- Horizontall AHU: 2000 CFM at 50 mm static pressure. (4.82 T.R.), (LIB
MR AOR:3 ARCHIVE STORE LY 201E )
No. 1.00 70,490.18 70,490
i) ADMIN- Horizontall AHU: 1500 CFM at 50 mm static pressure. (3.44 T.R.),
MR AOR:3 (RECORDS LIBRARY LY 201F)
No. 1.00 65,133.26 65,133
j) ADMIN- Horizontall AHU: 3800 CFM at 50 mm static pressure. (12.12 T.R.), (CLASS
MR AOR:3 ROOM CAP 20 to 30 LH 201 & LH 202)
No. 1.00 111,113.49 111,113
k) ADMIN- Horizontall AHU: 3800 CFM at 50 mm static pressure. (12.12 T.R.), (CLASS
MR AOR:3 ROOM CAP 20 to 30 LH 203 & LH 204)
No. 1.00 111,113.49 111,113
l) ADMIN- Horizontall AHU: 6500 CFM at 50 mm static pressure. (17.23 T.R.),
MR AOR:3 (READING AREA LY 201A)
No. 1.00 158,284.15 158,284
m) ADMIN- Horizontall AHU: 7000 CFM at 50 mm static pressure. (15.03 T.R.),
MR AOR:3 (READING AREA LY 201A)
No. 2.00 160,665.00 321,330

593
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SECOND FLOOR
-
ADMIN- Floor Mounted AHU: 4600 CFM at 50 mm static pressure. (10.08 T.R.),
a) MR AOR:4 (OFFICE LHS)
No. 2.00 133,582.80 267,166
ADMIN- Floor Mounted AHU: 4900 CFM at 50 mm static pressure. (10.64 T.R.),
b) MR AOR:4 (OFFICE RHS)
No. 2.00 136,261.26 272,523
ADMIN- Floor Mounted AHU: 3600 CFM at 50 mm static pressure. (8.17 T.R.),
c) MR AOR:4 (LOUNGE OR LIBRARY + COMMON AREA (1/2 of comm. Area))
No. 2.00 109,327.85 218,656
ADMIN- Floor Mounted AHU: 2200 CFM at 50 mm static pressure. (4.69T.R.),
d) MR AOR:4 (DISPLAY AREA + COMMON AREA (1/4 of comm. Area))
No. 1.00 82,394.45 82,394
ADMIN- Floor Mounted AHU: 2200 CFM at 50 mm static pressure. (6.83T.R.),
e) MR AOR:4 (WAITING LOUNGE + COMMON AREA (1/4 of comm. Area))
No. 1.00 82,394.45 82,394
-
THIRD FLOOR
-
ADMIN- Floor Mounted AHU: 4600 CFM at 50 mm static pressure. (10.0 8T.R.),
a) MR AOR:4 (OFFICE LHS)
No. 2.00 133,582.80 267,166
ADMIN- Floor Mounted AHU: 4900 CFM at 50 mm static pressure. (10.64 T.R.),
b) MR AOR:4 (OFFICE RHS)
No. 2.00 136,261.26 272,523
ADMIN- Floor Mounted AHU: 4700 CFM at 50 mm static pressure. (10.98 T.R.),
AOR:4 (ADDITIONAL DIRECTOR LHS+MEETING ROOM LHS+COMMON AREA
c) MR
(1/4 of comm. Area))
No. 1.00 134,475.62 134,476
ADMIN- Floor Mounted AHU: 2500 CFM at 50 mm static pressure. (6.28 T.R.),
AOR:4 (JOINT DIRECTOR LHS+WAITING OR SECURITY (1/2 AREA)+COMMON
d) MR
AREA (1/4 of comm. Area)
No. 1.00 89,537.01 89,537

594
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ADMIN- Floor Mounted AHU: 2900 CFM at 50 mm static pressure. (7.51T.R.),
AOR:4 (ADDITIONAL DIRECTOR RHS+MEETING ROOM RHS+COMMON AREA
e) MR
(1/4 of comm. Area)
No. 1.00 97,125.98 97,126
ADMIN- Floor Mounted AHU: 2500 CFM at 50 mm static pressure. (6.27 T.R.),
AOR:4 (JOINT DIRECTOR RHS+WAITING OR SECURITY (1/2 AREA) +COMMON
f) MR
AREA (1/4 of comm. Area)
No. 1.00 89,537.01 89,537
-
FOURTH FLOOR
-
ADMIN- Floor Mounted AHU: 4600 CFM at 50 mm static pressure. (10.0 8T.R.),
a) MR AOR:5 (OFFICE LHS)
No. 2.00 133,582.80 267,166
ADMIN- Floor Mounted AHU: 4900 CFM at 50 mm static pressure. (10.64 T.R.),
b) MR AOR:5 (OFFICE RHS)
No. 2.00 136,261.26 272,523
ADMIN- Floor Mounted AHU: 7700 CFM at 50 mm static pressure. (16.12 T.R.),
c) MR AOR:5 (DIRECTOR GENERAL + COMMON AREA (1/4 of comm. Area))
No. 1.00 161,557.82 161,558
ADMIN- Floor Mounted AHU: 5600 CFM at 50 mm static pressure. (11.79 T.R.),
d) MR AOR:5 (DIRECTOR + COMMON AREA (1/4 of comm. Area))
No. 1.00 141,320.57 141,321
ADMIN- Floor Mounted AHU: 5300 CFM at 50 mm static pressure. (12.34 T.R.),
e) MR AOR:5 (WAITING OR SECURITY + COMMON AREA (1/4 of comm. Area))
No. 1.00 138,790.91 138,791
ADMIN- Floor Mounted AHU: 8300 CFM at 50 mm static pressure. (18.64 T.R.),
f) MR AOR:5 (MEETING ROOM + COMMON AREA (1/4 of comm. Area))
No. 1.00 168,551.58 168,552
-
FIFTH FLOOR

-
ADMIN- Floor Mounted AHU: 4600 CFM at 50 mm static pressure. (10.0 8T.R.),
a) MR AOR:5 (OFFICE LHS)

No. 2.00 133,582.80 267,166

595
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ADMIN- Floor Mounted AHU: 4900 CFM at 50 mm static pressure. (10.64 T.R.),
b) MR AOR:5 (OFFICE RHS)

No. 2.00 136,261.26 272,523


-
SIXTH FLOOR

-
ADMIN- Floor Mounted AHU: 5350 CFM at 50 mm static pressure. (11.40 T.R.),
a) MR AOR:5 (OFFICE LHS)

No. 2.00 139,237.32 278,475


ADMIN- Floor Mounted AHU: 5650 CFM at 50 mm static pressure. (11.96 T.R.),
b) MR AOR:5 (OFFICE RHS)
No. 2.00 141,766.98 283,534
1.2 CEILING SUSPENDED UNIT:
-
Supply, Installation, Testing and commissioning of factory built ceiling
mounted chilled water double skin type air handling units made of
25mm thick panels consisting of pre plasticized G.I. casing of thickness
0.8mm outside layer and 0.8 mm inside layer with polyurethane foam
(PUF) insulation factory injected between them by injection moulding
machine, complete with blower section with blower suitable for static
pressure as required, minimum 2 bend GSS/PVC eliminators,cooling
coil section with aluminium finned copper tubes (tubes thickness not
less than 0.5mm) cooling coil of 4/6 row deep, filter section with 50mm
thick metal viscous/ washable synthetic type air prefilters, belt drive
package with TEFC drive EFF-1 motor suitable for 415 ± 10% volts, 50Hz,
3 Phase AC supply, drain connections, stainless steel (18G) drain pan
with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and
industrial type thermometers (2 nos.) at the inlet and outlet of coil,
auto purge valve wherever required, necessary vibration isolation
arrangement etc. complete as per specification and of following
capacities. Noise level is from each ahu at 1 mtr distance shall not
exceed 65 dB. Additional 12 / 13 mm thick insulation to apply for all
the AHUs surface area externally(for CSUs only). -

596
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ADMIN- Ceiling Mounted AHU: 2700 CFM at 40 mm static pressure. (5.66 T.R.),
a) MR AOR:6 (DATA & SERVER DT 201)
No. 1.00 81,352.83 81,353
ADMIN- Ceiling Mounted AHU: 1800 CFM at 40 mm static pressure. (4.41 T.R.),
b) MR AOR:6 (CASUAL READING LY 201)
No. 1.00 64,091.64 64,092
ADMIN- Ceiling Mounted AHU: 2700 CFM at 40 mm static pressure. (6.74 T.R.),
c) MR AOR:6 (CASUAL READING LY 201C)
No. 1.00 81,352.83 81,353
d) ADMIN- Ceiling Mounted AHU: 1200 CFM at 50 mm static pressure. (3.01 T.R.),
MR AOR:6 (VIDEO CONFERENCING VC 201 )
No. 1.00 52,782.58 52,783
e) ADMIN- Ceiling Mounted AHU: 1600 CFM at 50 mm static pressure. (3.86 T.R.),
MR AOR:6 (VIDEO CONFERENCING VC 201 )
No. 1.00 61,115.57 61,116

2.0 FAN COIL UNITS:


-
Supply, installation, testing and commissioning of ceiling mounted
type horizontal fan coil units complete with finned coil, fan section
with motor, drain pans, air filters, filter box, thermostat, control wiring
and other controls as per specifications and drawings.
-
ADMIN- 3.0 TR nominal capacity - 1200 CFM
a) MR
AOR:7 No. 1.00 21,839.69 21,840
ADMIN- 2.5 TR nominal capacity - 1000 CFM
b) MR AOR:7 No. 1.00 19,875.49 19,875
ADMIN- 2.0 TR nominal capacity - 800 CFM
c) MR AOR:7 No. 1.00 17,911.29 17,911
ADMIN- 1.5 TR nominal capacity - 600 CFM
d) MR
AOR:7 No. 2.00 16,274.45 32,549
ADMIN- 1.0 TR nominal capacity - 400 CFM
e) MR
AOR:7 No. 1.00 14,310.24 14,310

597
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.0 Supply, Installation, Testing and Commissioning of wall mounted split
type Air-conditioning unit including air cooled condensing unit
consisting copper tube aluminium finned condenser coil, air cooled
by suitable size low speed fan, all mounted in heavy gauge sheet
steel enclosure with protective painting evaporating Unit consisting of
copper tube aluminium finned high transfer cooling coil, refrigerant
distributor and thermostatic expansion Valve along with blower, filters
and drain pan all in heavy gauge sheet steel metal enclosure with
protective painting, M.S stande complete in all respect as required,
comprising of following:

ADMIN- 1.0 TR
a) MR AOR:8
No. 10.00 31,013.39 310,134
ADMIN- 1.5 TR
b) MR AOR:8
No. 50.00 37,329.97 1,866,499
ADMIN- 2.0 TR
c) MR AOR:8
No. 50.00 48,068.16 2,403,408
4.0 PRECISION AC

Supply, installation, testing and commissioning of Factory built


MICROPROCESSOR BASED PRECISION A/C UNITS as per the
specifications complete with air cooled condenser fan, scroll,
compressor, evaporator coil with hydrophilic coating, EC brushless
motor, backward curved/ direct driven fan, first fill of refrigerant, 24 hrs
performance test with necessary heat load, multistage electric heater,
variable capacity humidifier and vibration isolator. EFF1 High
efficiency Motor shall be suitable for 415 + 10% volts, 50 cycles, 3
phase AC supply and external static pressure shall be 300 Pa. Outdoor
unit motor should be with IP-65 protection and should be weather
proof. PAC shall have bottom throw. Auto sequencing of the unit for
equal run time should be integral part of the microprocessor and
conforming to the specifications.

598
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Each Unit shall be complete with powder coated electrical panel and
double earthing. The cables should be Cross linked polythene
insultate, armoured Copper cabling, with a low smoke and flame
sheath (XLPE/SWA/LSF) and all termination between main panel and
PAC should have double compression gland. Timers shall be provided
in Electrical panel for delayed start of units.
Quoted price shall be inclusive of copper, insulated drain pipipng,
control & power cabling from MCB to indoor unit & it also includes GI
trayfor supporting the refrigerant pipes (wherever exposed to sun)
between indoor and outdoor units.

The units shall deliver actual capacity at 43.3 Deg C. The unit nominal
capacities shall be after taking deration into account due to copper
piping length and ambient conditions. The system should be capable
of operating with total one way length as the drawing.

Condensers should be adequately sized for high ambient


temperatures not exceeding 56 Deg C.

The air cooled units shall be complete copper refrigerant piping with
nitrile rubber insulation as per specifications.

Environment free refrigerant - 407C/ 410A/ Equivalent

a) ADMIN- 4200 CFM at 30 mm static, 8.1 TR Microprocessor based PAHU units


MR AOR:9
No. 2.00 415,884.29 831,769

TOTAL CARRIED OVER TO SUMMARY


15,449,912

599
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

II) PART- B : PIPING:

1.0 Insulated Chilled Water Piping (Expanded Polystrene Insulation):

DSR 16.1 Supplying, laying/ fixing, testing and commissioning of following


nominal sizes of chilled water piping plumbing inside the building (with
necessary clamps, vibration isolators and fittings but excluding valves,
strainers, gauges etc.) duly insulated with fire retardant quality
expanded polystrene moulded pipe section of density 20 kg/cu.m
after a thick coat of cold setting adhesive (CPRX compound)
wrapping with 500g polythene faced hessain and finally applying
0.63mm aluminium sheet cladding complete with type3 , grade 1
roofing feltstrip(as per IS:1322 as amended up to date ) at joints
repairing of damage to building etc. as per specifications and as
required complete in all respect.clamps, supports, antivibration,
hangers, fittings such as bends, tees, reducers etc and installed with all
welded joints complete as per specification & drawings.

Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS
: 1239 and pipes size above 150mm shall be welded black steel pipe
heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for
pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for
pipes of 400 mm dia and above.

DSR 300 mm dia MS pipes (75 mm insulation)


a) 16.1.3 RM 250.00 6,282.00 1,570,500
b) DSR 250 mm dia MS pipes (75 mm insulation)
16.1.4 RM 200.00 5,309.00 1,061,800

600
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
c) DSR 200 mm dia MS pipes (75 mm insulation)
16.1.5 RM 100.00 4,419.00 441,900
d) DSR 150 mm dia MS pipes (75 mm insulation)
16.1.6 RM 100.00 2,884.00 288,400
e) DSR 125 mm dia MS pipes (50 mm insulation)
16.1.7 RM 225.00 2,452.00 551,700
f) DSR 100 mm dia MS pipes (50 mm insulation)
16.1.8 RM 190.00 2,118.00 402,420
g) DSR 80 mm dia MS pipes (50 mm insulation)
16.1.9 RM 100.00 1,595.00 159,500
h) DSR 65 mm dia MS pipes (50 mm insulation)
16.1.10 RM 89.00 1,374.00 122,286
i) DSR 50 mm dia MS pipes (50 mm insulation)
16.1.11 RM 74.00 1,130.00 83,620
j) DSR 40 mm dia MS pipes (50 mm insulation)
16.1.12 RM 100.00 954.00 95,400
k) DSR 32 mm dia MS pipes (50 mm insulation)
16.1.13 RM 251.00 842.00 211,342
l) DSR 25 mm dia MS pipes (50 mm insulation)
16.1.14 RM 49.00 749.00 36,701
m) ADMIN- 20 mm dia MS pipes (50 mm insulation)
MR AOR:10 RM 20.00 210.07 4,201
n) ADMIN- 40 mm dia GI pipes ('B' class, for condensate drain)
MR AOR:10 RM 200.00 480.13 96,027
o) ADMIN- 32 mm dia GI pipes ('B' class, for condensate drain)
AOR:10
MR RM 200.00 405.28 81,055
p) ADMIN- 25 mm dia GI pipes ('B' class, for condensate drain)
AOR:10
MR RM 50.00 294.39 14,719

601
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
1.1 Insulated Burried Chilled Water Piping (Expanded Polystrene
Insulation):

DSR 16.1 Supplying, laying/ fixing, testing and commissioning of following


nominal sizes of chilled water piping plumbing inside the building (with
necessary clamps, vibration isolators and fittings but excluding valves,
strainers, gauges etc.) duly insulated with fire retardant quality
expanded polystrene moulded pipe section of density 20 kg/cu.m
after a thick coat of cold setting adhesive (CPRX compound)
wrapping with 500g polythene faced hessain and finally applying
0.63mm aluminium sheet cladding complete with type3 , grade 1
roofing feltstrip(as per IS:1322 as amended up to date ) at joints
repairing of damage to building etc. as per specifications and as
required complete in all respect.clamps, supports, antivibration,
hangers, fittings such as bends, tees, reducers etc and installed with all
welded joints complete as per specification & drawings.

Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS
: 1239 and pipes size above 150mm shall be welded black steel pipe
heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for
pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for
pipes of 400 mm dia and above.

Burried Chilled Water piping Carried out of Preinsulated MS Class C


Pipes as per IS 1239 for pipes upto 150mm NB and as per IS 3589 for
200mm NB and above as per Specs and and the insulation should be
complete as follows. Pre-insulated pipes with PUF insulation & HDPE
jacketing.

a) MR 300 mm dia MS pipes (75 mm insulation) RM 500.00 6,910.00 3,455,000


b) MR 200 mm dia MS pipes (75 mm insulation) RM 50.00 4,923.00 246,150
c) MR 150 mm dia MS pipes (75 mm insulation) RM 50.00 3,172.00 158,600
d) MR 100 mm dia MS pipes (50 mm insulation) RM 50.00 2,330.00 116,500

2.0 DSR 16.7 Insulated Valves:

602
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supplying, fixing, testing and commissioning of following valves,
strainers, gauges in the chilled water plumbing duly insulated to the
same specifications as the connected piping and adequately
supported as per specifications.

2.1 DSR 16.7.1 BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal &
O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as
specified.

a) DSR 16.7.1.1 200 mm dia


Nos. 22.00 10,982.00 241,604
b) DSR 16.7.1.3 125 mm dia
Nos. 4.00 5,654.00 22,616
c) DSR 16.7.1.5 80 mm dia
Nos. 10.00 3,638.00 36,380
d) DSR 16.7.1.6 65 mm dia
Nos. 8.00 3,269.00 26,152
e) DSR 16.7.1.7 50 mm dia
Nos. 38.00 2,978.00 113,164
f) DSR 16.7.1.8 40 mm dia
Nos. 66.00 2,629.00 173,514

2.2 BUTTERFLY VALVE (Motorized ) with C I body SS Disc, Nitrile Rubber Seal
& O- Ring PN 16 pressure rating for chilled water/ hot eater circulation
as specified.
-
-
a) ADMIN- 200 mm dia
AOR:11
MR Nos. 4.00 72,060.11 288,240

603
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.3 DSR 16.7.2 BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body
flanged construction with EPDM coated disc with long pitch with
protected out pipe insulation & PN 16 pressure rating for chilled / hot
water circulation as specified.
-
-
DSR 16.7.2.1 200 mm dia
a) Nos. 4.00 48,655.00 194,620
b) DSR 16.7.2.3 125 mm dia
Nos. 2.00 18,608.00 37,216
c) DSR 16.7.2.5 80 mm dia
Nos. 5.00 7,318.00 36,590
d) DSR 16.7.2.6 65 mm dia
Nos. 4.00 7,024.00 28,096
e) DSR 16.7.2.7 50 mm dia
Nos. 19.00 6,317.00 120,023
f) DSR 16.7.2.8 40 mm dia
Nos. 33.00 3,119.00 102,927
g) MR ADMIN- 32 mm dia
AOR:12
Nos. 10.00 4,653.32 46,533
h) MR ADMIN- 25 mm dia
AOR:12
Nos. 8.00 3,585.62 28,685
i) MR ADMIN- 20 mm dia
AOR:12
Nos. 3.00 3,553.62 10,661
-
2.4 DSR 16.7.3 NON - RETURN VALVE with duel plate of C I body SS plates vulcanized
NBR seal flanged end & PN 16 pressure rating for chilled / hot water
circulation including insulation as specified.
-
-
a) DSR 16.7.3.1 200 mm dia 9,530.00
Nos. 9.00 85,770
-

604
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.5 DSR 16.7.4 Y - STRAINER of Ductile CI Body flanged ends with stainless steel
strainer for chilled / hot water circulation including insulation as
specified.
-
-
DSR 16.7.4.1 200 mm dia
a) Nos. 9.00 20,741.00 186,669
b) DSR 16.7.4.5 80 mm dia
Nos. 5.00 4,948.00 24,740
c) DSR 16.7.4.6 65 mm dia
Nos. 4.00 4,746.00 18,984
d) DSR 16.7.4.7 50 mm dia
Nos. 19.00 3,446.00 65,474
e) DSR 16.7.4.8 40 mm dia
Nos. 33.00 2,423.00 79,959
f) MR ADMIN- 32 mm dia
AOR:13
Nos. 10.00 2,107.79 21,078
g) MR ADMIN- 25 mm dia
AOR:13
Nos. 8.00 2,099.79 16,798
-
2.6 Suction Guide with integral strainer, drain plugs and suitable supports.
The strainer shall be selected to suit the pump suction diameter
complete with necessary accessories like flanges, fasteners, etc.,

-
-
a) MR ADMIN- 200 mm dia
AOR:14
Nos. 9.00 21,262.39 191,361

605
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.7 Bellows type rubber expansion joints for Chilled water piping located
at Pump inlet & exit, AHU inlet & exit and at chiller inlet & exit ahu.
Complete with double bellows, tie rods, MS flanges, necessary
hardware and gaskets etc., with insulation of following sizes:
-
-
a) MR ADMIN- 200 mm dia
AOR:15
Nos. 18.00 9,819.36 176,748
b) MR ADMIN- 125 mm dia
AOR:15
Nos. 4.00 6,445.40 25,782
c) MR ADMIN- 80 mm dia
AOR:15
Nos. 10.00 4,624.14 46,241
d) MR ADMIN- 65 mm dia
AOR:15
Nos. 8.00 3,880.21 31,042
e) MR ADMIN- 50 mm dia
AOR:15
Nos. 38.00 3,448.04 131,026
f) MR ADMIN- 40 mm dia
AOR:15
Nos. 66.00 3,099.23 204,549
g) MR ADMIN- 32 mm dia
AOR:15
Nos. 20.00 2,716.45 54,329
h) MR ADMIN- 25 mm dia
AOR:15
Nos. 16.00 2,559.02 40,944
-

606
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.8 AHU & FCU water side control comprising of 2-way Modulating valve
flow control valve, electronic actuator, solid state RA Temp. sensor-
cum controller, power and control wiring, power supply unit etc. The
valve actuator and sensor shall also be compatible to any generic
DDCs available in the market. (Vendors to Select the valve suitable for
the AHU & FCU CW coil flow rate), with insulation
-
a) MR ADMIN- 80 mm dia
AOR:16
Nos. 5.00 38,076.57 190,383
b) MR ADMIN- 65 mm dia
AOR:16
Nos. 4.00 34,210.07 136,840
c) MR ADMIN- 50 mm dia
AOR:16
Nos. 19.00 21,940.72 416,874
d) MR ADMIN- 40 mm dia
AOR:16
Nos. 33.00 16,355.53 539,732
e) MR ADMIN- 32 mm dia
AOR:16
Nos. 10.00 14,169.04 141,690
f) MR ADMIN- 25 mm dia
AOR:16
Nos. 8.00 11,531.60 92,253
g) MR ADMIN- 20 mm dia
AOR:16
Nos. 3.00 4,216.42 12,649
-

607
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.9 Ball valves PN16 rating together with accessories like flanges, fasteners, etc.,
-
-
a) MR ADMIN- 32 mm dia
AOR:17
Nos. 20.00 1,843.69 36,874
b) MR ADMIN- 25 mm dia
AOR:17
Nos. 16.00 1,187.87 19,006
-
2.10 Ball valves PN16 rating with and without Strainer together with accessories
like flanges, fasteners, etc., for FCU
-
-
a) MR ADMIN- 25 mm dia
AOR:18
Set 1.00 1,418.22 1,418
b) MR ADMIN- 20 mm dia
AOR:18
Set 3.00 1,233.71 3,701
-
3.0 DSR 16.8 Providing and fixing in position the industrial type pressure gauges with
gun metal / brass valves complete as required
Nos. 46.00 958.00 44,068
-
4.0 DSR 16.9 Providing & fixing in position the mercury in glass industrial type
thermometers.
Nos. 26.00 688.00 17,888
-
5.0 MR Supply, installation, testing and commissioning of Closed Expansion
tank for chilled water application duly pressurized complete with
piping connections, safety relief valve, drain valve, pressure gauge,
etc. complete as per specifications. Tank construction as per ASME,
Shell Material-Carbon Steel, Bladder-Heavy DutyButyl Rubber, system
connection - Forged Steel. The tank shall be duly painted in approved
color.
-

608
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Chilled water piping
-
Water Volume : 150 CuM
-
ADMIN- Safety working pressure : 3.5 bar
AOR:19
Set 1.00 493,157.08 493,157
-
6.0 MR Supply, installation, testing and commissioning of Air separator with
straining capability, automatic air purging arrangement etc. Body
made of Steel, Strainer-Galanised Steel, Duly insulated complete as
per specifications. The design parameters for the air separator of
efficiency 96-98 % should be as follows with Safety working pressure :
3.5 bar
-
Line Size: 300mm diameter;
-
ADMIN- Design Flow: 10070 LPM
AOR:20
Set 1.00 135,529.10 135,529

7.0 DSR 16.10 CONDENSER WATER PIPE -

DSR 16.10.1 Supplying, fixing, testing and commissioning of condenser water


Supplying, fixing, testing and commissioning of condenser water pipes
of following sizes of MS 'C' class along with necessary clamps, vibration
isolators and fittings such as bends,tees etc.but excluding valves,
strainers, gauges etc. adequately supported on rigid supports duly
painted/buried in ground excavation and refilling etc. as per
specification and as required complete in all respect. clamps,
vibration isolators and fittings such as bends,tees etc.but excluding
valves, strainers, gauges etc. adequately supported on rigid supports
duly painted/buried in ground excavation and refilling etc. as per
specification and as required complete in all respect.

609
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS :
1239 and pipes size above 150mm shall be welded black steel pipe
heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for
pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for
pipes of 400 mm dia and above. -
-
a) DSR 16.10.1.2 250mm dia.
RM 10.00 3,485.00 34,850
b) DSR 16.10.1.3 200mm dia.
RM 60.00 2,875.00 172,500
c) DSR 16.10.1.4 150mm dia.
RM 30.00 1,942.00 58,260
d) DSR 16.10.1.6 100 mm dia.
RM 20.00 1,399.00 27,980
e) MR ADMIN- 400 mm dia.
AOR:21
RM 125.00 6,486.30 810,788
-
8.0 VALVES WITHOUT INSULATION
-
-
DSR 16.11 Supplying, fixing, testing and commissioning of following valves,
gauges and strainers for condenser water circulation as per
specifications. -
8.1 DSR 16.11.1 BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring
& PN 16 pressure rating as specified.
-
a) DSR 16.11.1.1 200mm dia.
Nos. 16.00 10,199.00 163,184
b) DSR 16.11.1.4 100mm dia.
Nos. 4.00 4,615.00 18,460
c) DSR 16.11.1.7 50mm dia.
Nos. 8.00 2,634.00 21,072
d) MR ADMIN- 400mm dia.
AOR:22
Nos. 3.00 54,545.11 163,635
-

610
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.2 BUTTERFLY VALVE (Motorized ) with C I body SS Disc, Nitrile Rubber Seal
& O- Ring PN 16 pressure rating for chilled water/ hot eater circulation
as specified.
-
-
a) MR ADMIN- 200 mm dia
AOR:23
Nos. 8.00 71,273.11 570,185
-
8.3 DSR 16.7.2 BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body
flanged construction with EPDM coated disc with long pitch with
protected out pipe insulation & PN 16 pressure rating for chilled / hot
water circulation as specified.
-
-
a) DSR 16.7.2.1 200 mm dia Nos. 4.00 47,886.00 191,544
-
8.4 DSR 16.11.2 NON - RETURN VALVE with dual plate of C I body SS plates vulcanized
NBR seal flanged end & PN 16 pressure rating as specified.
-
-
a) DSR 16.11.2.1 200 mm dia
Nos. 4.00 8,740.00 34,960
-
8.5 DSR 16.7.4 Y - STRAINER of Ductile CI Body flanged ends with stainless steel
strainer for chilled / hot water circulation including insulation as
specified.
-
-
a) DSR 16.7.4.1 200 mm dia Nos. 4.00 19,954.00 79,816

8.6 Suction Guide with integral strainer, drain plugs and suitable supports.
The strainer shall be selected to suit the pump suction diameter
complete with necessary accessories like flanges, fasteners, etc.,

611
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
a) MR ADMIN- 200 mm dia
AOR:24
Nos. 4.00 20,475.39 81,902
-
8.7 Bellows type rubber expansion joints for condenser water piping
located at Pump inlet & exit and at condenser inlet & exit. Complete
with double bellows, tie rods, MS flanges, necessary hardware and
gaskets etc., with insulation of following sizes:
-
-
a) MR ADMIN- 200 mm dia
AOR:25
Nos. 16.00 9,819.36 157,110
-
8.8 Self Cleaning Pot Stainner Cum Sediment Separator fabricated out of
MS IS 226 with SS 304 filter element at outlet of Cooling Tower
-
-
a) MR ADMIN- 400 mm dia
AOR:26
Nos. 1.00 111,084.87 111,085
-
9.0 MR ADMIN- Supply, installation, testing and commissioning of 10mmdia.
AOR:27 Automatic air vent in brass construction complete with nipples, union
etc. as required at all high points in the pipe lines. The valve shall be
such as to have non-return valve as integral part of the vent.
Nos. 10.00 1,384.48 13,845
-
10.0 MR ADMIN- Supply, Installation, Testing, & Commissioning of 25mm diameter Plug
AOR:28 valves in dirt legs complete with nipples etc. as required per
specifications. Nos. 40.00 1,889.82 75,593
-
11.0 MR ADMIN- Providing and fixing in position of approved make differential pressure
AOR:29 switch complete with copper control wiring at condenser and chiller
outlet of each machine.
Nos. 8.00 1,194.12 9,553

612
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

TOTAL CARRIED OVER TO SUMMARY 17,184,722

III) PART- C : MECHANICAL VENTILATION WORK:


-
-
1.0 Sheet Metal Duct:
-

1.1 DSR 16.12.1 Supply, installation, balancing and commissioning of factory


fabricated GSS sheet metal rectangular/round ducting complete with
neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,
supports etc. as per approved drawings and specifications of following
sheet thickness complete as required.
-
-
a) DSR 16.12.1.1 Thickness 0.63 mm sheet
Sqm 1,999.00 725.00 1,449,275
b) DSR 16.12.1.2 Thickness 0.80 mm sheet
Sqm 7,750.00 890.00 6,897,500
c) DSR 16.12.1.3 Thickness 1.00 mm sheet
Sqm 300.00 1,004.00 301,200
-
1.2 DSR 16.12.2 Supply, installation, balancing and commissioning of fabricated at site
GSS sheet metal rectangular/round ducting complete with neoprene
rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc.
as per approved drawings and specifications of following sheet
thickness complete as required.
-
-
a) DSR 16.12.2.1 Thickness 0.63 mm sheet 605.00
Sqm 501.00 303,105
b) DSR 16.12.2.2 Thickness 0.80 mm sheet 728.00
Sqm 1,940.00 1,412,320
c) DSR 16.12.2.3 Thickness 1.00 mm sheet 949.00
Sqm 85.00 80,665
-

613
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.0 DSR 16.13 Supply, installation, testing and commissioning of GI volume control
duct damper complete with neoprene rubber gaskets, nuts, bolts,
screws linkages, flanges etc, as per specifications
Sqm 6.00 5,413.00 32,478
-
3.0 DSR 16.15 Supplying & fixing of powder coated extruded aluminium
Supply/Exhaust Air Grills with aluminium volume control dampers as
per specifications.
Sqm 225.00 7,107.00 1,599,075
-
FANS FOR SMOKE EXHAUST OF INTERNAL AREA IN CASE OF FIRE
4.0 -
Supply, Installation, Testing & Commissioning of long casing(GSS) Tube
Axial flow type fans complete with aluminium alloy blades with
aerofoil design, bird screen, flexible connection & gravity louvers at
outlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt
distance from fan outlet shall not be more than 90db(A) (Room
Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. Manufacturer shall
submit “Certificate of conformity for 250 deg for 2 hours operation as
per EN12101-3: 2002 issued by Internationally recognized Independent
Fire Laboratory should be submitted along with type test report. RPM
Should Not exceed 950 for the capacity above 31000 cfm. For the
capacity between 4001 cfm to 31000 cfm RPM should not exceed
1450. However lower cfm upto 4000 CFM can be provided at 2850
RPM. Outlet velocity shuld not exceed 18 m/s

-
Ground Floor
4.1 -
ADMIN- 1200 cfm capacity with 30 mm static pressure for Internal Area Incase
AOR:30 of fire
a) MR Nos. 4.00 57,371.02 229,484
ADMIN- 3600 cfm capacity with 40 mm static pressure for Internal Area Incase
AOR:30 of fire
b) MR Nos. 2.00 73,491.12 146,982

614
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ADMIN- 3800 cfm capacity with 40 mm static pressure for Internal Area Incase
AOR:30 of fire
c) MR Nos. 8.00 73,491.12 587,929
ADMIN- 4400 cfm capacity with 40 mm static pressure for Internal Area Incase
AOR:30 of fire
d) MR Nos. 2.00 77,789.81 155,580
ADMIN- 5000 cfm capacity with 40 mm static pressure for Internal Area Incase
AOR:30 of fire
e) MR Nos. 2.00 83,493.85 166,988
ADMIN- 14000 cfm capacity with 35 mm static pressure for Internal Common
AOR:30 Area Incase of fire
f) MR Nos. 8.00 152,355.61 1,218,845
ADMIN- 25000 cfm capacity with 40 mm static pressure for Internal Area
AOR:30 Incase of fire
g) MR Nos. 1.00 228,409.41 228,409
-
First Floor
4.2 -
ADMIN- 1800 cfm capacity with 30 mm static pressure for Internal Area Incase
AOR:31 of fire
a) MR Nos. 1.00 63,240.39 63,240
ADMIN- 2000 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
b) MR Nos. 1.00 62,827.05 62,827
ADMIN- 2200 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
c) MR Nos. 1.00 62,827.05 62,827
ADMIN- 2500 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
d) MR Nos. 2.00 62,827.05 125,654
ADMIN- 2900 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
e) MR Nos. 1.00 66,051.07 66,051
ADMIN- 3800 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
f) MR Nos. 2.00 68,448.42 136,897

615
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ADMIN- 4400 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
g) MR Nos. 2.00 77,789.81 155,580
ADMIN- 4500 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
h) MR Nos. 1.00 77,789.81 77,790
ADMIN- 4700 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
i) MR Nos. 1.00 77,789.81 77,790
ADMIN- 6800 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
j) MR Nos. 2.00 117,139.39 234,279
ADMIN- 7900 cfm capacity with 35 mm static pressure for Internal Area Incase
AOR:31 of fire
k) MR Nos. 1.00 126,811.45 126,811
-
FOR LHS & RHS TOWER
4.3 -
ADMIN- 10350 cfm capacity with 40 mm static pressure for Internal Area
AOR:32 Incase of fire
a) MR Nos. 4.00 152,355.61 609,422
-

FOR CIRCULAR TOWER


4.4 -
ADMIN- 10750 cfm capacity with 40 mm static pressure for Internal Area
AOR:32 Incase of fire
a) MR Nos. 2.00 152,355.61 304,711
ADMIN- 9600 cfm capacity with 40 mm static pressure for Internal Area Incase
AOR:32 of fire
b) MR Nos. 2.00 152,355.61 304,711

616
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
5.0 FANS FOR SMOKE EXHAUST IN NORMAL CASE
-
Supply, Installation, Testing & Commissioning of long casing (GSS)
Vane Axial flow type fans complete with aluminium alloy blades with
aerofoil design, bird screen, flexible connection & gravity louvers at
outlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt
distance from fan outlet shall not be more than 80db(A) (Room
Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. Manufacturer shall
submit “Certificate of conformity for 250 deg for 2 hours operation as
per EN12101-3: 2002 issued by Internationally recognized Independent
Fire Laboratory should be submitted along with type test report. RPM
Should Not exceed 950 for the capacity above 31000 cfm. For the
capacity between 4001 cfm to 31000 cfm RPM should not exceed
1450. However lower cfm upto 4000 CFM can be provided at 2850
RPM. Outlet velocity shuld not exceed 15 m/s -
5.1 Basement
-
ADMIN- 35000 cfm capacity with 50 mm static pressure for Car Parking Normal
AOR:33 Ventilation with EFF-1 motor
a) MR Nos. 12.00 653,318.69 7,839,824
6.0 FANS FOR SMOKE EXHAUST IN CASE OF FIRE
-
Supply, Installation, Testing & Commissioning of long casing(GSS) Tube
Axial flow type fans complete with aluminium alloy blades with
aerofoil design, bird screen, flexible connection & gravity louvers at
outlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt
distance from fan outlet shall not be more than 90db(A) (Room
Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. Manufacturer shall
submit “Certificate of conformity for 250 deg for 2 hours operation as
per EN12101-3: 2002 issued by Internationally recognized Independent
Fire Laboratory should be submitted along with type test report. RPM
Should Not exceed 950 for the capacity above 31000 cfm. For the
capacity between 4001 cfm to 31000 cfm RPM should not exceed
1450. However lower cfm upto 4000 CFM can be provided at 2850
RPM. Outlet velocity shuld not exceed 18 m/s. -

617
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
6.1 Basement
-
ADMIN- 26250 cfm capacity with 50 mm static pressure for Car Parking Area
AOR:34 Incase of fire
a) MR Nos. 24.00 260,566.94 6,253,607
FANS FOR SUPPLY IN CASE OF NORMAL
7.0 -
Supply, Installation, Testing & Commissioning of long casing(GSS) Vane
Axial flow type supply air fans complete with aluminium alloy blades
with aerofoil design, bird screen, flexible connection & gravity louvers
at outlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt
distance from fan outlet shall not be more than 80db(A) (Room
Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. RPM Should Not exceed
950 for the capacity above 31000 cfm. For the capacity between
4001 cfm to 31000 cfm RPM should not exceed 1450. However lower
cfm upto 4000 CFM can be provided at 2850 RPM. Outlet velocity
shuld not exceed 15 m/s

-
-
BASEMENT
7.1 -
ADMIN- 35000 cfm capacity with 50 mm static pressure for Car Parking Normal
AOR:35 Ventilation with EFF-1 motor
a) MR Nos. 10.00 554,118.08 5,541,181

618
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
-
FANS FOR SUPPLY IN CASE OF FIRE
8.0 -
Supply, Installation, Testing & Commissioning of long casing(GSS) Tube
Axial flow type supply air fans complete with aluminium alloy blades
with aerofoil design, bird screen, flexible connection & gravity louvers
at outlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt
distance from fan outlet shall not be more than 90db(A) (Room
Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified..”RPM Should Not
exceed 950 for the capacity above 31000 cfm. For the capacity
between 4001 cfm to 31000 cfm RPM should not exceed 1450.
However lower cfm upto 4000 CFM can be provided at 2850 RPM.
Outlet velocity shuld not exceed 18 m/s

-
-
BASEMENT
8.1 -
ADMIN- 26250 cfm capacity with 50 mm static pressure for Internal Area
a) MR AOR:36 Incase of fire Nos. 20.00 260,566.94 5,211,339
-
9.0 TOILET VENTILATION /FRESH AIR INLINE FAN
-
Supply, Installation, Testing and commissioning of exhaust air fan
section suitable for Inline mounting comprising of forward curved
centrifugal blower complete with external rotor induction motor /
Induction 3 phase motor, metal clad MCB & starter with 'hands", "off",
automatic mode selection switch, 15 m length cable, earthing,
canvas connection all compete as required, suitable for single phase,
230 / 415volts, 50Hz AC. supply as per specifications of following
capacities: Fan along with the cabinet should be AMCA certified.
Noiselevel should not exceed 65dB(A)at 3 meter in room condition.
-
ADMIN- 3000 cfm capacity with25 mm static pressure (AHU FA)
a) MR AOR:37 Nos. 4.00 81,179.17 324,717

619
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ADMIN- 2600 cfm capacity with25 mm static pressure (Toilet Exhaust)
b) MR AOR:37 Nos. 2.00 71,837.78 143,676
ADMIN- 1600 cfm capacity with25 mm static pressure (Toilet Exhaust)
c) MR AOR:37 Nos. 4.00 41,746.92 166,988
ADMIN- 1400 cfm capacity with25 mm static pressure (AHU FA)
d) MR AOR:37 Nos. 2.00 41,746.92 83,494
ADMIN- 800 cfm capacity with25 mm static pressure (AHU FA)
e) MR AOR:37 Nos. 3.00 36,208.22 108,625
ADMIN- 700 cfm capacity with25 mm static pressure (Toilet Exhaust)
f) MR AOR:37 Nos. 4.00 36,208.22 144,833
ADMIN- 600 cfm capacity with25 mm static pressure (AHU FA)
g) MR AOR:37 Nos. 1.00 36,208.22 36,208
ADMIN- 500 cfm capacity with25 mm static pressure (AHU FA)
h) MR AOR:37 Nos. 2.00 36,208.22 72,416
ADMIN- 400 cfm capacity with25 mm static pressure (Toilet Exhaust)
i) MR AOR:37 Nos. 7.00 36,208.22 253,458

TUBE AXIAL FLOW FANS(Lift lobby, Lift well & Staircase Pressurisation):

10.0 -
Supply, Installation, Testing & Commissioning of long casing(GSS) Tube
Axial flow type supply air fans complete with aluminium alloy blades
with aerofoil design, bird screen, flexible connection & gravity louvers
at outlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt
distance from fan outlet shall not be more than 90db(A) (Room
Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. RPM Should Not exceed
950 for the capacity above 31000 cfm. For the capacity between
4001 cfm to 31000 cfm RPM should not exceed 1450. However lower
cfm upto 4000 CFM can be provided at 2850 RPM. Outlet velocity
shuld not exceed 18 m/s -
ADMIN- 12000 cfm capacity with25 mm static pressure for lift well Academic
AOR:38 Block
a) MR Nos. 5.00 106,971.33 534,857

620
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ADMIN- 5000 cfm capacity with25 mm static pressure for lift lobby Academic
AOR:38 Block in basement
b) MR Nos. 3.00 79,195.15 237,585
ADMIN- 12000 cfm capacity with 35 mm static pressure for lift lobby
AOR:38 Academic Block in tower
c) MR Nos. 2.00 123,752.76 247,506
-
PROPELLER FAN
11.0 -
Supply, Installation, Testing and commissioning etc as required, wall
mounted propeller type exhaust fans shall be of Axial Flow type with
light weight type PVC / aluminium impellers with aerofoil contours for
high efficiency and low noise. The fan shall be supplied complete with
wooden frames and gravity louvers with a suitable Squirrel cage
induction motor.
-
ADMIN- 450 mm dia
AOR:39
a) MR Nos. 10.00 34,472.21 344,722
ADMIN- 300 mm dia
AOR:39
b) MR Nos. 5.00 16,037.43 80,187
-
12.0 ADMIN- Supplying, installing and testing of exhaust air GI outlet louvers with
AOR:40 bird screen complete as per specification & drawings.
Sqm 160.00 6,460.04 1,033,607
-
13.0 ADMIN- Supplying, installing and testing of fresh air GI intake louvers with bird
AOR:40 screen complete as per spefifications and drawings.
Sqm 110.00 6,460.04 710,605
-
TOTAL CARRIED OVER TO SUMMARY
46,587,858

621
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
IV) PART- D : AIR DISTRIBUTION SYSTEM

1.0 Sheet Metal Duct:

1.1 DSR 16.12.1 Supply, installation, balancing and commissioning of factory


fabricated GSS sheet metal rectangular/round ducting complete with
neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,
supports etc. as per approved drawings and specifications of following
sheet thickness complete as required.

a) DSR 16.12.1.1 Thickness 0.63 mm sheet

Sqm 8,850.00 725.00 6,416,250


b) DSR 16.12.1.2 Thickness 0.80 mm sheet

Sqm 6,205.00 890.00 5,522,450


c) DSR 16.12.1.3 Thickness 1.00 mm sheet

Sqm 3,390.00 1,004.00 3,403,560


-
1.2 DSR 16.12.2 Supply, installation, balancing and commissioning of fabricated at site
GSS sheet metal rectangular/round ducting complete with neoprene
rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc.
as per approved drawings and specifications of following sheet
thickness complete as required.
-
-
a) DSR 16.12.2.1 Thickness 0.63 mm sheet Sqm 2,205.00 605.00 1,334,025
b) DSR 16.12.2.2 Thickness 0.80 mm sheet Sqm 1,140.00 728.00 829,920
c) DSR 16.12.2.3 Thickness 1.00 mm sheet Sqm 445.00 949.00 422,305
-

622
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.0 DSR 16.13 Supply, installation, testing and commissioning of GI volume control
duct damper complete with neoprene rubber gaskets, nuts, bolts,
screws linkages, flanges etc, as per specifications
Sqm 14.80 5,413.00 80,112
-
3.0 DSR 16.15 Supplying & fixing of powder coated extruded aluminium Supply Air
Grills with aluminium volume control dampers as per specifications.
Sqm 135.00 7,107.00 959,445
-
4.0 DSR 16.16 Supplying & fixing of powder coated extruded aluminium Return Air
Grills with louvers but without volume control dampers complete as
required. Sqm 140.00 4,040.00 565,600
-
5.0 DSR 16.17 Supplying, fixing testing commissioning of supply air diffusers of powder
coated aluminium with aluminium volume control dampers with anti
smudge ring & removable core.

Sqm 90.00 8,661.00 779,490


-
6.0 DSR 16.18 Supplying, fixing testing commissioning of Return air diffusers of powder
coated aluminium without volume control dampers with anti smudge
ring & removable core. Sqm 77.00 5,594.00 430,738
-
7.0 DSR 16.20 Supplying, Fixing,testing and commissioning of fire dampers in supply
air duct/main branch and return air path as and where required of
required sizes i/c control wiring,the damper shall be motorized and
spring return so as to close the damper in the event of power failure
automatically and open the same in case of power being restored.
The spring return action shall be inbuilt mechanism and not externally
mounted. The damper shall also be closed in the event of fire signal
complete as required and as per specifications.
-
a) DSR 16.20.1 Fire damper
Sqm 85.00 7,053.00 599,505
b) DSR 16.20.2 Actuator
Nos. 250.00 6,551.00 1,637,750
-

623
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
8.0 DSR 16.21 Supply and fixing of acoustic lining of supply air duct and plenum with
25 mm thick resin bonded glass wool having density of 32 kg/m³, with
25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to
centre covered with Reinforced Plastic tissue paper and 0.5 mm thick
perforated aluminum sheet fixed to inside surface of ducts with
cadmium plated nuts, bolts, stick pins, CPRX compound etc.
complete as required and as per specifications.
Sqm 3,745.00 543.00 2,033,535
-
9.0 DSR 16.22 Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with
50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation
friction fixed in 610mm x 610 mm frame work made of 25 X 50 X50 X 50
X 25 mm made out of 0.6mm thick GI sheet U shaped channel and
covered with reinforced fiber glass tissue and finished with 0.80 mm
perforated aluminium sheet etc. complete as required and as per
specifications.
Sqm 10,830.00 864.00 9,357,120
-
10.0 DSR 16.23 Supplying and fixing of following thickness duly laminated aluminum
foil of mat finish closed cell Nitrile rubber (class "O") insulation on
existing duct after applying two coats of cold setting adhesive (CPR X
compound). The joints shall sealed with 50 mm wide and 3 mm thick
self adhesive nitrile rubber tape insulation complete as per
specifications and as required.
-

a) DSR 16.23.1 19mm


Sqm 15,050.00 816.00 12,280,800
b) DSR 16.23.2 25mm
Sqm 2,890.00 1,029.00 2,973,810
-
TOTAL CARRIED OVER TO SUMMARY
49,626,415

624
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATE COST OF HVAC WORKS (HOSTEL BLOCK)

SUB HEAD OF WORKS ESTIMATED


SUBHEAD NO
AMOUNT IN INR

I) PART- A : AIR CIRCULATION SYSTEM: 5,812,462

II) PART- B : PIPING: 12,297,736

III) PART- C : MECHANICAL VENTILATION WORK: 7,399,281

IV) PART- D : AIR DISTRIBUTION SYSTEM 11,683,355

TOTAL AMOUNT 37,192,834

LESS 5% FOR UPRNN WORKING (1,859,642)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 35,333,192

625
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATE COST OF HVAC WORKS (HOSTEL BLOCK)

I) PART- A : AIR CIRCULATION SYSTEM:

1.0 AIR HANDLING UNIT:

1.1 CEILING SUSPENDED UNIT: -


Supply, Installation, Testing and commissioning of factory built ceiling mounted
chilled water double skin type air handling units made of 25mm thick panels
consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm
inside layer with polyurethane foam (PUF) insulation factory injected between them
by injection moulding machine, complete with blower section with blower suitable
for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil
section with aluminium finned copper tubes (tubes thickness not less than 0.5mm)
cooling coil of 4/6 row deep, filter section with 50mm thick metal viscous/ washable
synthetic type air prefilters, belt drive package with TEFC drive EFF-1 motor suitable
for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel
(18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2
nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto
purge valve wherever required, necessary vibration isolation arrangement etc.
complete as per specification and of following capacities. Noise level is from each
ahu at 1 mtr distance shall not exceed 65 dB. Additional 12 / 13 mm thick insulation
to apply for all the AHUs surface area externally (for CSUs only).

-
HOSTEL- Ceiling Mounted AHU: 1800 CFM at 40 mm static pressure. (3.58 T.R.), (ENT AND
a) MR AOR:1 LIFT LOBBY LHS)
No. 1.00 64,091.64 64,092
HOSTEL- Ceiling Mounted AHU: 1800 CFM at 40 mm static pressure. (3.58 T.R.), (ENT AND
b) MR AOR:1 LIFT LOBBY RHS)
No. 1.00 64,091.64 64,092
HOSTEL- Ceiling Mounted AHU: 3500 CFM at 40 mm static pressure. (8.31 T.R.), (TABLE
c) MR AOR:1 TENNIS)
No. 1.00 97,721.19 97,721

626
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
HOSTEL- Ceiling Mounted AHU: 3400 CFM at 40 mm static pressure. (10.25 T.R.), (GYM)
d) MR AOR:1
No. 2.00 92,513.08 185,026
HOSTEL- Ceiling Mounted AHU: 2800 CFM at 40 mm static pressure. (6.67 T.R.), (BILLIARDS
e) MR AOR:1 HALL)
No. 1.00 82,245.65 82,246
-
2.0 TREATED FRESH UNIT:
-
-
2.1 CEILING SUSPENDED UNIT: -
Supply, Installation, Testing and commissioning of factory built ceiling mounted
chilled water double skin type treated fresh air units made of 25mm thick panels
consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm
inside layer with polyurethane foam (PUF) insulation factory injected between them
by injection moulding machine, complete with blower section with blower suitable
for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil
section with aluminium finned copper tubes (tubes thickness not less than 0.5mm)
cooling coil of 8 row deep, filter section with 50mm thick metal viscous/ washable
synthetic type air prefilters, belt drive package with TEFC drive EFF-1 motor suitable
for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel
(18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)
and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge
valve wherever required, necessary vibration isolation arrangement etc. complete as
per specification and of following capacities. Noise level is from each ahu at 1 mtr
distance shall not exceed 65 dB. Additional 12 / 13 mm thick insulation to apply for
all the AHUs surface area externally (for CSUs only).

-
HOSTEL- Ceiling Mounted TFA: 1580 CFM at 45 mm static pressure. (11.2 T.R.), (CORRIDOR &
a) MR AOR:2 GUEST ROOMS 1ST TO 4TH FLOOR)
No. 8.00 84,328.89 674,631
HOSTEL- Ceiling Mounted TFA: 1460 CFM at 45 mm static pressure. (10.4 T.R.), (CORRIDOR &
b) MR AOR:2 GUEST ROOMS 5TH TO 15TH FLOOR)
No. 22.00 82,394.45 1,812,678
-

627
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.0 FAN COIL UNITS:
-
Supply, installation, testing and commissioning of ceiling mounted type horizontal
fan coil units complete with finned coil, fan section with motor, drain pans, air
filters, filter box, thermostat, control wiring and other controls as per specifications
and drawings.
-
-
HOSTEL- 2.0 TR nominal capacity - 800 CFM
a) MR AOR:3
No. 7.00 17,575.19 123,026
HOSTEL- 1.5 TR nominal capacity - 600 CFM
b) MR AOR:3
No. 145.00 15,970.36 2,315,702
HOSTEL- 1.0 TR nominal capacity - 400 CFM
c) MR AOR:3
No. 28.00 14,044.57 393,248

TOTAL CARRIED OVER TO SUMMARY 5,812,462

II) PART- B : PIPING:

1.0 Insulated Chilled Water Piping (Expanded Polystrene Insulation):

DSR 16.1 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of
chilled water piping plumbing inside the building (with necessary clamps, vibration
isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with
fire retardant quality expanded polystrene moulded pipe section of density 20
kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with
500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding
complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date)
at joints repairing of damage to building etc. as per specifications and as required
complete in all respect.clamps, supports, antivibration, hangers, fittings such as
bends, tees, reducers etc and installed with all welded joints complete as per
specification & drawings.

628
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and
pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589,
from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from
minimum 7mm thick MS sheet for pipes of 400 mm dia and above.

DSR 200 mm dia MS pipes (75 mm insulation)


a) 16.1.5 RM 500.00 4,419.00 2,209,500
b) DSR 150 mm dia MS pipes (75 mm insulation)
16.1.6 RM 400.00 2,884.00 1,153,600
c) DSR 125 mm dia MS pipes (50 mm insulation)
16.1.7 RM 250.00 2,452.00 613,000
d) DSR 100 mm dia MS pipes (50 mm insulation)
16.1.8 RM 250.00 2,118.00 529,500
e) DSR 80 mm dia MS pipes (50 mm insulation)
16.1.9 RM 125.00 1,595.00 199,375
f) DSR 65 mm dia MS pipes (50 mm insulation)
16.1.10 RM 125.00 1,374.00 171,750
g) DSR 50 mm dia MS pipes (50 mm insulation)
16.1.11 RM 40.00 1,130.00 45,200
h) DSR 40 mm dia MS pipes (50 mm insulation)
16.1.12 RM 250.00 954.00 238,500
i) DSR 32 mm dia MS pipes (50 mm insulation)
16.1.13 RM 1,100.00 842.00 926,200
j) DSR 25 mm dia MS pipes (50 mm insulation)
16.1.14 RM 2,850.00 749.00 2,134,650
HOSTEL- 20 mm dia MS pipes (50 mm insulation)
AOR:4
k) MR RM 1,940.00 210.07 407,527
l) HOSTEL- 40 mm dia GI pipes ('B' class, for condensate drain)
AOR:4
MR RM 75.00 480.13 36,010
m) HOSTEL- 32 mm dia GI pipes ('B' class, for condensate drain)
AOR:4
MR RM 75.00 405.28 30,396
n) HOSTEL- 25 mm dia GI pipes ('B' class, for condensate drain)
AOR:4
MR RM 1,500.00 294.39 441,582

629
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

2.0 DSR 16.7 Insulated Valves:


Supplying, fixing, testing and commissioning of following valves, strainers, gauges in
the chilled water plumbing duly insulated to the same specifications as the
connected piping and adequately supported as per specifications.

2.1 DSR 16.7.1 BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN
16 pressure rating for chilled water/ hot eater circulation as specified.

-
a) DSR 16.7.1.7 50 mm dia
Nos. 16.00 2,978.00 47,648
b) DSR 16.7.1.8 40 mm dia
Nos. 52.00 2,629.00 136,708
-
2.2 DSR 16.7.2 BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged
construction with EPDM coated disc with long pitch with protected out pipe
insulation & PN 16 pressure rating for chilled / hot water circulation as specified.

-
-
a) DSR 16.7.2.7 50 mm dia
Nos. 8.00 6,317.00 50,536
b) DSR 16.7.2.8 40 mm dia
Nos. 26.00 3,119.00 81,094
c) MR HOSTEL- 32 mm dia
AOR:5
Nos. 2.00 4,653.32 9,307
d) MR HOSTEL- 25 mm dia
AOR:5
Nos. 7.00 3,585.62 25,099
e) MR HOSTEL- 20 mm dia
AOR:5
Nos. 173.00 3,553.62 614,776
-

630
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.3 DSR 16.7.4 Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled /
hot water circulation including insulation as specified.
-
-
a) DSR 16.7.4.7 50 mm dia Nos. 8.00 3,446.00 27,568
b) DSR 16.7.4.8 40 mm dia Nos. 26.00 2,423.00 62,998
c) MR HOSTEL- 32 mm dia
AOR:6
Nos. 2.00 2,107.79 4,216
2.4 Bellows type rubber expansion joints for Chilled water piping located at Pump inlet
& exit, AHU inlet & exit and at chiller inlet & exit ahu. Complete with double
bellows, tie rods, MS flanges, necessary hardware and gaskets etc., with insulation
of following sizes:
-
a) MR HOSTEL- 50 mm dia
AOR:7 Nos. 16.00 3,448.04 55,169
b) MR HOSTEL- 40 mm dia
AOR:7 Nos. 52.00 3,099.23 161,160
c) MR HOSTEL- 32 mm dia
AOR:7 Nos. 4.00 2,716.45 10,866
2.5 AHU & FCU water side control comprising of 2-way Modulating valve flow control
valve, electronic actuator, solid state RA Temp. sensor-cum controller, power and
control wiring, power supply unit etc. The valve actuator and sensor shall also be
compatible to any generic DDCs available in the market. (Vendors to Select the valve
suitable for the AHU & FCU CW coil flow rate), with insulation
-
a) MR HOSTEL- 50 mm dia
AOR:8 Nos. 8.00 22,182.72 177,462
b) MR HOSTEL- 40 mm dia
AOR:8 Nos. 26.00 16,393.53 426,232
c) MR HOSTEL- 32 mm dia
AOR:8 Nos. 2.00 14,217.04 28,434
d) MR HOSTEL- 25 mm dia
AOR:8 Nos. 7.00 11,620.60 81,344
e) MR HOSTEL- 20 mm dia
AOR:8 Nos. 173.00 4,299.42 743,800
-

631
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.6 Ball valves PN16 rating together with accessories like flanges, fasteners, etc.,
-
-
a) MR HOSTEL- 32 mm dia
AOR:9
Nos. 4.00 1,843.69 7,375
-
2.7 Ball valves PN16 rating with and without Strainer together with accessories like
flanges, fasteners, etc., for FCU
-
-
a) MR HOSTEL- 25 mm dia
AOR:10
Set 7.00 1,418.22 9,928
b) MR HOSTEL- 20 mm dia
AOR:10
Set 173.00 1,233.71 213,432
-
3.0 MR HOSTEL- Supply, installation, testing and commissioning of 10mmdia. Automatic air vent in
AOR:11 brass construction complete with nipples, union etc. as required at all high points in
the pipe lines. The valve shall be such as to have non-return valve as integral part of
the vent.
Nos. 25.00 1,384.48 34,612
-
4.0 MR HOSTEL- Supply, Installation, Testing, & Commissioning of 25mm diameter Plug valves in dirt
AOR:12 legs complete with nipples etc. as required per specifications.

Nos. 80.00 1,889.82 151,185


-
TOTAL CARRIED OVER TO SUMMARY
12,297,736
-

632
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

III) PART- C : MECHANICAL VENTILATION WORK:


-

-
1.0 Sheet Metal Duct:
-

1.1 DSR 16.12.1 Supply, installation, balancing and commissioning of factory fabricated GSS sheet
metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,
splitter dampers, vanes, hangers, supports etc. as per approved drawings and
specifications of following sheet thickness complete as required.

-
-
a) DSR 16.12.1.1 Thickness 0.63 mm sheet
Sqm 270.00 725.00 195,750
b) DSR 16.12.1.2 Thickness 0.80 mm sheet
Sqm 1,000.00 890.00 890,000
c) DSR 16.12.1.3 Thickness 1.00 mm sheet
Sqm 50.00 1,004.00 50,200
-
1.2 DSR 16.12.2 Supply, installation, balancing and commissioning of fabricated at site GSS sheet
metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,
splitter dampers, vanes, hangers, supports etc. as per approved drawings and
specifications of following sheet thickness complete as required.

-
-
a) DSR 16.12.2.1 Thickness 0.63 mm sheet
Sqm 65.00 605.00 39,325
b) DSR 16.12.2.2 Thickness 0.80 mm sheet
Sqm 250.00 728.00 182,000
c) DSR 16.12.2.3 Thickness 1.00 mm sheet
Sqm 10.00 949.00 9,490
-
2.0 DSR 16.13 Supply, installation, testing and commissioning of GI volume control duct damper
complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc. as
per specifications
Sqm 2.00 5,413.00 10,826
-

633
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
3.0 DSR 16.15 Supplying & fixing of powder coated extruded aluminium Supply/Exhaust Air Grills
with aluminium volume control dampers as per specifications.
Sqm 30.00 7,107.00 213,210
-
4.0 FANS FOR SMOKE EXHAUST OF INTERNAL AREA IN CASE OF FIRE -
Supply, Installation, Testing & Commissioning of long casing(GSS) Tube Axial flow
type fans complete with aluminium alloy blades with aerofoil design, bird screen,
flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10% volts, 50
Hz. Sound level at 3mt distance from fan outlet shall not be more than 90db(A)
(Room Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. Manufacturer shall submit “Certificate
of conformity for 250 deg for 2 hours operation as per EN12101-3: 2002 issued by
Internationally recognized Independent Fire Laboratory should be submitted along
with type test report. RPM Should Not exceed 950 for the capacity above 31000 cfm.
For the capacity between 4001 cfm to 31000 cfm RPM should not exceed 1450.
However lower cfm upto 4000 CFM can be provided at 2850 RPM. Outlet velocity
shuld not exceed 18 m/s

-
Guest Corridor
4.1 -
HOSTEL- 8100 cfm capacity with 50 mm static pressure for guest corridor Incase of fire
AOR:13
a) MR Nos. 2.00 150,206.26 300,413

-
FANS FOR SMOKE EXHAUST IN NORMAL CASE
5.0 -

634
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing & Commissioning of long casing(GSS) Vane Axial flow
type fans complete with aluminium alloy blades with aerofoil design, bird screen,
flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10% volts, 50
Hz. Sound level at 3mt distance from fan outlet shall not be more than 80db(A)
(Room Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. Manufacturer shall submit “Certificate
of conformity for 250 deg for 2 hours operation as per EN12101-3: 2002 issued by
Internationally recognized Independent Fire Laboratory should be submitted along
with type test report. RPM Should Not exceed 950 for the capacity above 31000 cfm.
For the capacity between 4001 cfm to 31000 cfm RPM should not exceed 1450.
However lower cfm upto 4000 CFM can be provided at 2850 RPM. Outlet velocity
shuld not exceed 15 m/s

-
Basement
5.1 -
HOSTEL- 39000 cfm capacity with 50 mm static pressure for Car Parking Normal Ventilation
AOR:14 with EFF-1 motor
a) MR Nos. 3.00 711,351.05 2,134,053
-
FANS FOR SMOKE EXHAUST IN CASE OF FIRE
6.0 -
Supply, Installation, Testing & Commissioning of long casing(GSS) Tube Axial flow
type fans complete with aluminium alloy blades with aerofoil design, bird screen,
flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10% volts, 50
Hz. Sound level at 3mt distance from fan outlet shall not be more than 90db(A)
(Room Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. Manufacturer shall submit “Certificate
of conformity for 250 deg for 2 hours operation as per EN12101-3: 2002 issued by
Internationally recognized Independent Fire Laboratory should be submitted along
with type test report. RPM Should Not exceed 950 for the capacity above 31000 cfm.
For the capacity between 4001 cfm to 31000 cfm RPM should not exceed 1450.
However lower cfm upto 4000 CFM can be provided at 2850 RPM. Outlet velocity
shuld not exceed 18 m/s

-
Basement
6.1 -

635
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
HOSTEL- 29250 cfm capacity with 40 mm static pressure for Internal Area Incase of fire
a) MR AOR:15 Nos. 6.00 289,417.78 1,736,507
7.0 TOILET VENTILATION INLINE FAN -
Supply, Installation, Testing and commissioning of exhaust air fan section suitable
for Inline mounting comprising of forward curved centrifugal blower complete with
external rotor induction motor / Induction 3 phase motor, metal clad MCB & starter
with 'hands", "off", automatic mode selection switch, 15 m length cable, earthing,
canvas connection all compete as required, suitable for single phase, 230 / 415volts,
50Hz AC. supply as per specifications of following capacities: Fan along with the
cabinet should be AMCA certified. Noiselevel should not exceed 65dB(A)at 3 meter
in room condition.

-
HOSTEL- 18300 cfm capacity with 40 mm static pressure
a) MR AOR:16 Nos. 2.00 408,375.85 816,752
-
TUBE AXIAL FLOW FANS(Lift lobby, Lift well & Staircase Pressurisation):
8.0 -
Supply, Installation, Testing & Commissioning of long casing(GSS) Tube Axial flow
type supply air fans complete with aluminium alloy blades with aerofoil design, bird
screen, flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10%
volts, 50 Hz. Sound level at 3mt distance from fan outlet shall not be more than
90db(A) (Room Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. RPM Should Not exceed 950 for the
capacity above 31000 cfm. For the capacity between 4001 cfm to 31000 cfm RPM
should not exceed 1450. However lower cfm upto 4000 CFM can be provided at 2850
RPM. Outlet velocity shuld not exceed 15 m/s.

-
a) MR HOSTEL- 16000 cfm capacity with25 mm static pressure for lift well hostel block
AOR:17
Nos. 4.00 49,104.30 196,417
-
PROPELLER FAN
9.0 -

636
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Supply, Installation, Testing and commissioning etc as required, wall mounted
propeller type exhaust fans shall be of Axial Flow type with light weight type PVC /
aluminium impellers with aerofoil contours for high efficiency and low noise. The fan
shall be supplied complete with wooden frames and gravity louvers with a suitable
Squirrel cage induction motor.
-
a) MR HOSTEL- 450 mm dia
AOR:18
Nos. 5.00 34,472.21 172,361
b) MR HOSTEL- 300 mm dia
AOR:18
Nos. 2.00 16,037.43 32,075
-
10.0 MR HOSTEL- Supplying, installing and testing of exhaust air GI outlet louvers with bird screen
AOR:19 complete as per specification & drawings.
Sqm 40.00 6,460.04 258,402
-
11.0 MR HOSTEL- Supplying, installing and testing of fresh air GI intake louvers with bird screen
AOR:19 complete as per spefifications and drawings.
Sqm 25.00 6,460.04 161,501
-
TOTAL CARRIED OVER TO SUMMARY
7,399,281

IV) PART- D : AIR DISTRIBUTION SYSTEM


1.0 Sheet Metal Duct:

1.1 DSR 16.12.1 Supply, installation, balancing and commissioning of factory fabricated GSS sheet
metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,
splitter dampers, vanes, hangers, supports etc. as per approved drawings and
specifications of following sheet thickness complete as required.

a) DSR 16.12.1.2 Thickness 0.80 mm sheet


Sqm 3,225.00 890.00 2,870,250
b) DSR 16.12.1.3 Thickness 1.00 mm sheet
Sqm 1,200.00 1,004.00 1,204,800
-

637
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
1.2 DSR 16.12.2 Supply, installation, balancing and commissioning of fabricated at site GSS sheet
metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,
splitter dampers, vanes, hangers, supports etc. as per approved drawings and
specifications of following sheet thickness complete as required.

-
-
a) DSR 16.12.2.2 Thickness 0.80 mm sheet
Sqm 730.00 728.00 531,440
b) DSR 16.12.2.3 Thickness 1.00 mm sheet
Sqm 300.00 949.00 284,700
-
2.0 DSR 16.15 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with
aluminium volume control dampers as per specifications.

Sqm 40.00 7,107.00 284,280


-
3.0 DSR 16.16 Supplying & fixing of powder coated extruded aluminium Return Air Grills with
louvers but without volume control dampers complete as required.

Sqm 34.00 4,040.00 137,360


-
4.0 DSR 16.17 Supplying, fixing testing commissioning of supply air diffusers of powder coated
aluminium with aluminium volume control dampers with anti smudge ring &
removable core.
Sqm 30.00 8,661.00 259,830
-
5.0 DSR 16.18 Supplying, fixing testing commissioning of Return air diffusers of powder coated
aluminium without volume control dampers with anti smudge ring & removable
core.
Sqm 20.00 5,594.00 111,880
-

638
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.0 DSR 16.20 Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main
branch and return air path as and where required of required sizes i/c control
wiring,the damper shall be motorized and spring return so as to close the damper in
the event of power failure automatically and open the same in case of power being
restored. The spring return action shall be inbuilt mechanism and not externally
mounted. The damper shall also be closed in the event of fire signal complete as
required and as per specifications.
-

a) DSR 16.20.1 Fire damper


Sqm 5.00 7,053.00 35,265
b) DSR 16.20.2 Actuator
Nos. 15.00 6,551.00 98,265
-
7.0 DSR 16.21 Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick
resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section
of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue
paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts
with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as
required and as per specifications.
Sqm 2,725.00 543.00 1,479,675
-
8.0 DSR 16.23 Supplying and fixing of following thickness duly laminated aluminum foil of mat
finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying
two coats of cold setting adhesive (CPR X compound). The joints shall sealed with 50
mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per
specifications and as required.
-

a) DSR 16.23.1 19mm


Sqm 4,000.00 816.00 3,264,000
b) DSR 16.23.2 25mm
Sqm 1,090.00 1,029.00 1,121,610
-
TOTAL CARRIED OVER TO SUMMARY
11,683,355

639
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATED COST OF HVAC WORKS FOR RESIDENTIAL BLOCK

SUBHEAD OF WORKS ESTIMATED


SUBHEAD NO
AMOUNT IN INR

0.0 0.00 0 PART- A : MECHANICAL VENTILATION WORK: 6,173,140

TOTAL AMOUNT 6,173,140

LESS 5% FOR UPRNN WORKING (308,657)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 5,864,483

640
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
COST ESTIMATE FOR HVAC WORKS

Item Code Description Amount


S.No. Sch Ref. Unit Qty. Rate (Rs.)
No. (Rs.)
-
I) PART- A : MECHANICAL VENTILATION WORK:
-
-
1.0 Sheet Metal Duct:
-

1.1 DSR 16.12.1 Supply, installation, balancing and commissioning of factory fabricated GSS sheet
metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,
splitter dampers, vanes, hangers, supports etc. as per approved drawings and
specifications of following sheet thickness complete as required.
-
-
a) DSR 16.12.1.1 Thickness 0.63 mm sheet Sqm. 245.00 725.00 177,625
b) DSR 16.12.1.2 Thickness 0.80 mm sheet Sqm. 1,000.00 890.00 890,000
c) DSR 16.12.1.3 Thickness 1.00 mm sheet Sqm. 50.00 1,004.00 50,200
-
1.2 DSR 16.12.2 Supply, installation, balancing and commissioning of fabricated at site GSS sheet
metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,
splitter dampers, vanes, hangers, supports etc. as per approved drawings and
specifications of following sheet thickness complete as required.
-
-
a) DSR 16.12.2.1 Thickness 0.63 mm sheet 605.00
Sqm. 65.00 39,325
b) DSR 16.12.2.2 Thickness 0.80 mm sheet Sqm. 250.00 728.00 182,000
c) DSR 16.12.2.3 Thickness 1.00 mm sheet Sqm. 10.00 949.00 9,490
-

641
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.0 DSR 16.13 Supply, installation, testing and commissioning of GI volume control duct damper
complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as
per specifications
Sqm. 2.00 5,413.00 10,826
-
3.0 DSR 16.15 Supplying & fixing of powder coated extruded aluminium Supply/Exhaust Air Grills
with aluminium volume control dampers as per specifications.
Sqm. 30.00 7,107.00 213,210
-
FANS FOR SMOKE EXHAUST IN NORMAL CASE
4.0 -
Supply, Installation, Testing & Commissioning of long casing(GSS) Vane Axial flow
type fans complete with aluminium alloy blades with aerofoil design, bird screen,
flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10% volts, 50
Hz. Sound level at 3mt distance from fan outlet shall not be more than 80db(A)
(Room Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. Manufacturer shall submit “Certificate
of conformity for 250 deg for 2 hours operation as per EN12101-3: 2002 issued by
Internationally recognized Independent Fire Laboratory should be submitted along
with type test report. RPM Should Not exceed 950 for the capacity above 31000 cfm.
For the capacity between 4001 cfm to 31000 cfm RPM should not exceed 1450.
However lower cfm upto 4000 CFM can be provided at 2850 RPM. Outlet velocity
shuld not exceed 15 m/s

-
Residential Block
-
Basement
4.1 -
RES-AOR:1 34000 cfm capacity with 50 mm static pressure for Car Parking Normal Ventilation
with EFF-1 motor
a) MR Nos. 2.00 606,033.07 1,212,066
RES-AOR:1 36000 cfm capacity with 50 mm static pressure for Car Parking Normal Ventilation
with EFF-1 motor
b) MR Nos. 1.00 606,033.07 606,033

642
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
FANS FOR SMOKE EXHAUST IN CASE OF FIRE
5.0 -
Supply, Installation, Testing & Commissioning of long casing(GSS) Tube Axial flow
type fans complete with aluminium alloy blades with aerofoil design, bird screen,
flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10% volts, 50
Hz. Sound level at 3mt distance from fan outlet shall not be more than 90db(A)
(Room Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. Manufacturer shall submit “Certificate
of conformity for 250 deg for 2 hours operation as per EN12101-3: 2002 issued by
Internationally recognized Independent Fire Laboratory should be submitted along
with type test report. RPM Should Not exceed 950 for the capacity above 31000 cfm.
For the capacity between 4001 cfm to 31000 cfm RPM should not exceed 1450.
However lower cfm upto 4000 CFM can be provided at 2850 RPM. Outlet velocity
shuld not exceed 18 m/s

-
Residential Block

-
Basement

5.1 -
a) MR RES-AOR:2 25500 cfm capacity with 50 mm static pressure for Car Parking Area Incase of fire

Nos. 4.00 228,409.41 913,638


b) MR RES-AOR:2 26000 cfm capacity with 50 mm static pressure for Car Parking Area Incase of fire

Nos. 2.00 228,409.41 456,819

643
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
TUBE AXIAL FLOW FANS (Lift lobby, Lift well & Staircase Pressurisation):

6.0 -
Supply, Installation, Testing & Commissioning of long casing(GSS) Tube Axial flow
type supply air fans complete with aluminium alloy blades with aerofoil design, bird
screen, flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10%
volts, 50 Hz. Sound level at 3mt distance from fan outlet shall not be more than
90db(A) (Room Condition). Capacity shall be as follows & as per detailed technical
specification: Fans should be AMCA certified. RPM Should Not exceed 950 for the
capacity above 31000 cfm. For the capacity between 4001 cfm to 31000 cfm RPM
should not exceed 1450. However lower cfm upto 4000 CFM can be provided at 2850
RPM. Outlet velocity shuld not exceed 18 m/s

-
RES-AOR:3 8500 cfm capacity with 25 mm static pressure for lift lobby residential block

a) MR Nos. 2.00 90,851.23 181,702


RES-AOR:3 16900 cfm capacity with 25 mm static pressure for lift lobby residential block

b) MR Nos. 4.00 132,846.15 531,385


RES-AOR:3 16900 cfm capacity with 35 mm static pressure for staircase pressurization
residential block
c) MR Nos. 2.00 139,459.53 278,919

-
7.0 RES-AOR:4 Supplying, installing and testing of exhaust air GI outlet louvers with bird screen
complete as per specification & drawings.
MR Sqm 40.00 6,460.04 258,402
-
8.0 RES-AOR:4 Supplying, installing and testing of fresh air GI intake louvers with bird screen
complete as per spefifications and drawings.
MR Sqm 25.00 6,460.04 161,501

TOTAL CARRIED OVER TO SUMMARY


6,173,140

644
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY COST OF ADDITIONAL WORKS LIKE BOOM BARRIERS, GAS SUPPRESSION SYSTEM FOR
7
SERVER, RODENT CONTROL

SUB HEAD ESTIMATED


SUB HEAD OF WORKS
NO AMOUNT IN INR

7.01 BOOM BARRIER 2,093,000

7.02 RODENT CONTROL SYSTEM 200,000

7.03 GAS SUPRESSION SYSTEM 2,700,000

TOTAL COST OF ADDITIONAL WORKS 4,993,000

LESS 5% FOR UPRNN WORKING (249,650)

NET AMOUNT IN INR CARRIED OVER TO ABSTRACT 4,743,350

645
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY COST OF ADDITIONAL WORKS BOOM BARRIERS

S.No Description of items Unit Quantity RATE AMOUNT

A BOOM BARRIERS

1 Supply of Boom barriers 6 M long with inbuilt crash protection feature, each 8.00 228,285.00 1,826,280
manula override, integration with smart card, push buttons, safety rubber,
ohoto cell sensor for safety, long rane UHF reader, controller at entry and exit,
induction loop detector, poles for installation of reader

2 Software each 1.00 38,000.00 38,000

3 RFID wind shield Tags for cars each 700.00 115.00 80,500

1,944,780
VAT @ 12.5% 243,098

2,187,878
-
4 Installation, testing and commisioning of barriers each 8.00 12,000.00 96,000

5 Service tax @ 12.36% 1,483.20 11,866

13,483.20 107,866
6 Freight, loading, unloading LS 30,000

Total amount 2,325,743

carried over to abstract 2,325,743


Note
Conduiting and CAT 5 wiring cost extra
Discount (232,574)
2,093,169
say 2,093,000

646
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SUMMARY COST OF ADDITIONAL WORKS RODENT CONTROL SYSTEM


Rodent Control system

S.No Description of item Unit Quantity Rate Amount

For Client Server Room


1 Design, Supply,Installation,Testing & Commissioning of Ultrasonic Pest Ls 1.00 200,000.00 200,000
Repellent System (Rodent Control) consisting of Master Console capable
of connecting to 12 Satellites complete with backet and all accessories as
per specifications.
Total amount including taxes 200,000
GAS SUPPRESSION SYSTEM
S.No Description of item Unit Quantity Rate Amount
I. Design, Supplym installation of GAS SUPPRESSION SYSTEM SAPPHIRE / NOVEC LS 1.00 2,700,000.00 2,700,000
i/c Integration with, Fire alarm system and building management system
consisting of Cylinder with Valve, Novec 1230 Gas, Master Cylinder
Comprising-'- Pr. Guage + Low Pr. Supervisory Switch, Electromagnetic
Actuator,Manual Actuator;Pneumatic Actuator; Flexible Discharge hose;
Felxible Actuation Hose, Slave Cylinder Comprising : Pr. Guage + Low Pr.
Supervisory Switch, Pneumatic Actuator;Flexible Discharge Hose;Flexible
Actuation Hose, Discharge Nozzles are designed to provide the proper flow
rate and distribution of FM-200 to total flood a hazard area: 180 deg. / 360
deg. , Sinorix Check Valve, 2 Way Manifold, Abort & Release Switch ,
Mounting Brackets, M.S. Seamless pipes as per ASTM A 106 Gr. B, Schedule 40
with necessary fittings, Gas Relase Fire Alarm Panel with Required accessories,
Electronic hooter & Signages as per standard requirement and fixing ISI
Marked 2 core x 1.5 mm2, Multistrand Copper, FRLS Armoured cable, RED in
Colour, laid on surface with GI saddle-spacers every 0.3 meters.
I Server Room ( Area 1300 Sqft ceiling height 3.2 M)

Total amount including taxes 2,700,000

647
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

8 SUMMARY COST OF UPS SYSTEM & INVERTER

SUB ESTIMATED
HEAD
HEAD NO AMOUNT IN INR

8.01 SUMMARY OF COST (ACADEMIC & ADMIN BLOCK) 4,198,616

8.02 SUMMARY OF COST (HOSTEL BLOCK) 37,383

8.03 SUMMARY OF COST (RESIDENCE TYPE -1 & 2) 37,383

8.04 SUMMARY OF COST (RESIDENCE TYPE -3 & 4) 37,383

TOTAL 4,310,765

648
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DETAILED COST ESTIMATE FOR ELECTRICAL WORKS: ACADEMIC & ADMIN BLOCK (EFC)

UPS SYSTEM & INVERTER:


SH- 01

1.00 Supply,Transprtation, storing at site, shifting at work place, installation, Testing


and commissioning of the following rating UPS/Inverter as per specifications
and complete in all respects.The scope also includes supply, Installation,
Testing and Commissioning of Sealed Maintenance Free lead acid Batteries
Non DSR complete with intercell connectors & copper cables, battery stand made
out of Powder Coated MS Angles with adequate supports to carry the load
of the batteries.& also TVSS at the input of each UPS to protect against
transients, surges & Noise as per the tender specifications

a 2 Nos. 120 KVA UPS in parallel mode with 15 minutes battery back up with
static & manual bypass Input Voltage: 3 Ph 415 Volts, ±10% Output : 3 -
Phase-415Volts, 50 Hz ±2% ,
Set 1.00 3,175,061.00 3,175,061

b 20 KVA UPS with ,15 Min battery backup , with static & manual bypass Input
Voltage: 3 Ph 415 Volts, ±10% Output : 3 -Phase-415Volts, 50 Hz ±2% ,
Nos 2.00 455,703.00 911,406

c 2 KVA Digital True Sine wave inverter , Offline, 90 Min battery back, Input
Voltage : 1 Ph 240 Volts, ±10% Output : 1-Phase-240Volts, 50 Hz ± 2%
Set 3.00 37,383.00 112,149

Total SH 01 - UPS SYSTEM & INVERTER


4,198,616

649
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DETAILED COST ESTIMATE FOR ELECTRICAL WORKS : HOSTEL BLOCK

SH- 01 UPS SYSTEM & INVERTER:

Supply,Transprtation, storing at site, shifting at work place, installation, Testing


and commissioning of the following rating UPS/Inverter as per specifications
and complete in all respects.The scope also includes supply, Installation,
Testing and Commissioning of Sealed Maintenance Free lead acid Batteries
1.00 Non DSR complete with intercell connectors & copper cables, battery stand made
out of Powder Coated MS Angles with adequate supports to carry the load
of the batteries.& also TVSS at the input of each UPS to protect against
transients, surges & Noise as per the tender specifications

2 KVA Digital True Sine wave inverter , Offline, 90 Min battery back, Input
a. Voltage : 1 Ph 240 Volts, ±10% Output : 1-Phase-240Volts, 50 Hz ± 2%
Set 1.00 37,383.00 37,383

Total SH 01 - UPS System


37,383

650
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DETAILED COST ESTIMATE FOR ELECTRICAL WORKS : RESIDENTIAL BLOCK 1 &2

UPS SYSTEM & INVERTER:


SH- 01

Supply,Transprtation, storing at site, shifting at work place, installation, Testing


and commissioning of the following rating UPS/Inverter as per specifications
and complete in all respects.The scope also includes supply, Installation,
Testing and Commissioning of Sealed Maintenance Free lead acid Batteries
1.00 Non DSR complete with intercell connectors & copper cables, battery stand made
out of Powder Coated MS Angles with adequate supports to carry the load
of the batteries.& also TVSS at the input of each UPS to protect against
transients, surges & Noise as per the tender specifications

2 KVA Digital True Sine wave inverter , Offline, 90 Min battery back, Input
Voltage : 1 Ph 240 Volts, ±10% Output : 1-Phase-240Volts, 50 Hz ± 2%
a.
Set 1.00 37,383.00 37,383

Total SH 01 - UPS System


37,383

651
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

DETAILED COST ESTIMATE FOR ELECTRICAL WORKS : RESIDENTIAL BLOCK 3 & 4

UPS SYSTEM & INVERTER:


SH- 01

Supply,Transprtation, storing at site, shifting at work place, installation, Testing


and commissioning of the following rating UPS/Inverter as per specifications
and complete in all respects.The scope also includes supply, Installation,
Testing and Commissioning of Sealed Maintenance Free lead acid Batteries
1.00 Non DSR complete with intercell connectors & copper cables, battery stand made
out of Powder Coated MS Angles with adequate supports to carry the load
of the batteries.& also TVSS at the input of each UPS to protect against
transients, surges & Noise as per the tender specifications

2 KVA Digital True Sine wave inverter , Offline, 90 Min battery back, Input
a. Voltage : 1 Ph 240 Volts, ±10% Output : 1-Phase-240Volts, 50 Hz ± 2%
Set 1.00 37,383.00 37,383

Total SH 01 - UPS System


37,383

652
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

9 ESTIMATED COST OF SURVILLANCE & SECURITY

SUB HEAD OF WORKS


SUB ESTIMATED
HEAD NO AMOUNT IN INR

9.01 SUMMARY OF COST (ACADEMIC & ADMIN BLOCK)

9.02 SUMMARY OF COST (HOSTEL BLOCK) (6660195 + 4903700) 11,563,895

9.03 SUMMARY OF COST (RESIDENCE TYPE -1 & 2) (3960300 + 101200) 4,061,500

9.04 SUMMARY OF COST (RESIDENCE TYPE -3 & 4) (401550 + 53000) 454,550

9.05 ACCESS CONTROL SYSTEM (533600 + 53000) 586,600

TOTAL 16,666,545

653
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATED COST OF SURVILLANCE & SECURITY
SURVILLANCE & SECURITY:
SH-02

SH-09A CCTV SYSTEM

1.00 Supply, Installation testing and Commissioning of IP Fixed indoor verifocal


lences 3.5-8mm auto iris 520 TVL POE camera including including integrated
housing (dome type)connectors,D/N, WDR, 3-9mm VF Auto-Iris Lens, IR Cut
Filter, H.264 30FPS,,Lens,camera mount and an ancillary Equipment & All
accessories complete as required. Make- Dv tel Model No- CM-4221-00 or
equivalent
Nos 105.00 29,700.00 3,118,500
2.00 Supply, Installation testing and Commissioning of IP Fixed outdoor verifocal
lences 3.5-8mm auto iris 480 TVL POE camera including including integrated
housing (dome type)connectors,Camera D/N, WDR, IR Cut-Filter, H.264 30fps,
1/2.7 CMOS, C/CS lens mount DC,Lens,camera mount and an ancillary
Equipment & All accessories complete as required. Make- Dv tel Model No-
CF-4221-00 or equivalent
Nos 20.00 43,020.00 860,400
3.00 LCD Display PTZ Controller for item no.1
Nos 1.00 62,550.00 62,550
4.00 Supply, Installation testing and Commissioning of IP Digital video
management software complete with compatible server grade PC for the
software,complete with licences equal to the number of camera,five client
licences,and all other licences required to integrate keybords,monitors
etc.The set shall come with RAID backup device sufficient to store all
cameras at 4CIF/D1 resolusion for minimum 30 Days Backups at 15 fps with all
accessories complete as required. Make- Dv tel Model No- USS-ENT-48R5-44
or equivalent
Nos 1.00 1,047,420.00 1,047,420
5.00 Supply, Installation testing and Commissioning of Cisco layer 3 switch with
number of 24 ports as to support all cameras and having 20% spare ports
complete with separete rack for each with all accessories as required.
Nos 1.00 164,160.00 164,160

654
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.00 Supply, Installation testing and Commissioning of Cisco layer 3 switch with
number of 16 ports as to support all cameras and having 20% spare ports
complete with separete rack for each with all accessories as required.

Nos 1.00 140,695.00 140,695

7.00 Supply, Installation testing and Commissioning of Cisco layer 3 switch with
number of 12 ports as to support all cameras and having 20% spare ports
complete with separete rack for each with all accessories as required.
Nos 3.00 117,270.00 351,810

8.00 Supply, Installation testing and Commissioning of 21" CCTV Colour TFT as
required including all accessories complete as required.
Nos 3.00 18,720.00 56,160

9.00 Supply and laying of 2 core twisted pair sheilded cable for communication in
existing 25mm PVC conduit.

Meter 700.00 50.00 35,000


10.00 Supply and surface laying of 2CX1.5 sq mm power cable in existing 25 mm
dia PVC conduit.
Nos 3,000.00 50.00 150,000

11.00 Supply and laying of CAT 6 cable for communication in existing 25mm PVC
conduit.
Nos 5,000.00 41.00 205,000
12.00 Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.

a DSR - 25mm
1.21.2 Metre 4,500.00 65.00 292,500
13.00 Supply and Laying of 8/16,1356/1520 mm multinode optical fibre cable in 16
SWG MS Conduit.
Nos 1,000.00 176.00 176,000

Total SH 02 A- CCTV SYSTEM


6,660,195

655
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-02 B ACCESS CONTROL SYSTEM

1.00 Supply Installation Testing & Comissioning of 32 bit TWO reader networkable
access controller with UL listing , IP integration with CCTV System.The
controller shall have capacity to handle 2 readers and 8 alarm inputs and
with IP on board technology complete with all accessories as required. Make-
HID or or equivalent
Nos 35.00 30,510.00 1,067,850
2.00 Supply Installation Testing & Comissioning of Access controll cum time
management integration management software for minimum of 256 readers
with elevator management along with complete P-IV,Windows 2000 or
HIGHER,1GB RAM,320GB or HIGHER HDD,104 key stroke keybord,52x OR better
CD/DVD RW drive PC or equivalent as required for the software along with 30
minutes backup UPS for Access system complete with all accessories as
required. Make- IDCUBE or equivalent
Nos 1.00 3,060.00 3,060
3.00 Supply Installation Testing & Comissioning of 3.5" read range Proximity card
reader,UL listed for all access doors exept for server room complete with all
accessories as required. Make- HID or equivalent
Nos 35.00 3,060.00 107,100
4.00 Supply Installation Testing & Comissioning of Biometric cum proximity card
reader, UL listed for server room complete with all accessories as required.
Make- HID or equivalent
Nos 10.00 50,850.00 508,500
5.00 Supply Installation Testing & Comissioning of Single electro magnetic locks for
single leaf access doors complete with all accessories as required. Make- Bell
or equivalent
Nos 6.00 1,710.00 10,260
6.00 Supply Installation Testing & Comissioning of Double electro magnetic locks
for dual leaf access doors complete with all accessories as required. Make-
Bell or equivalent
Nos 8.00 2,880.00 23,040

656
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
7.00 Supply Installation Testing & Comissioning of Magnetic contacts for all access
doors including for fire exit doors which shall be armed with panic bars
complete with all accessories as required. Make- Reputed
Nos 15.00 720.00 10,800
8.00 Supply Installation Testing & Comissioning of Push to exit botton complete
with all accessories as required. Make- Reputed
Nos 25.00 360.00 9,000
9.00 Supply of proximity card with lanyard & Photo ID complete as required.
Make- HID or equivalent
Nos 3,000.00 180.00 540,000
10.00 Supply Installation Testing & Comissioning of Half Height Flap Barrier
complete with all accessories as required.Make- Came or equivalent
Nos 4.00 273,600.00 1,094,400
OR

Half Height Turnstile.

11.00 Supply Installation Testing & Comissioning of Door Frame Metal Detector
complete with all accessories as required. Make- Garette or equivalent
Nos 2.00 243,090.00 486,180

12.00 Supply Installation Testing & Comissioning of 24 Zone Intrudion Pannel


complete with all accessories as required .Make- DSC or equivalent
Nos 1.00 20,610.00 20,610

13.00 Supply and Laying of 8cx 0.5 sq mm screen sheilded cable in existing condiut
/ cable tray as required . Make- Reputed
Nos 9,650.00 54.00 521,100
14.00 Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.
a DSR - 25mm
1.21.2 Metre 7,720.00 65.00 501,800

Total SH 02 B- CCTV SYSTEM


4,903,700

Total SH 02 - SURVEILLANCE & SECURITY


11,563,895

657
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

HOSTEL BLOCK

SH-02 SURVILLANCE & SECURITY:

CCTV SYSTEM
SH-02A

Supply, Installation testing and Commissioning of IP Fixed indoor verifocal


lences 3.5-8mm auto iris 520 TVL POE camera including including integrated
housing (dome type)connectors,D/N, WDR, 3-9mm VF Auto-Iris Lens, IR Cut
1.00 Filter, H.264 30FPS,,Lens,camera mount and an ancillary Equipment & All
accessories complete as required. Make- Dv tel Model No- CM-4221-00 or
equivalent
Nos 128.00 29,700.00 3,801,600

Supply and surface laying of 2CX1.5 sq mm power cable in existing 25 mm


2.00 dia PVC conduit.
Nos 500.00 50.00 25,000
-
Supply and laying of CAT 6 cable for communication in existing 25mm PVC
3.00 conduit.
Nos 1,000.00 40.00 40,000
-
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
4.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.
-
-
DSR - 25mm
a Metre
1.21.2 900.00 65.00 58,500
-
Supply and Laying of 8/16,1356/1520 mm multinode optical fibre cable in 16
5.00 SWG MS Conduit. Nos 200.00 176.00 35,200

Total SH 02 A- CCTV SYSTEM


3,960,300

658
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-02B ACCESS CONTROL SYSTEM

Supply and Laying of 8cx 0.5 sq mm screen sheilded cable in existing condiut
1.00 / cable tray as required . Make- Reputed
Nos 1,000.00 54.00 54,000

Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
2.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.

25mm
DSR -
a
1.21.2
Metre 800.00 59.00 47,200

Total SH 02 B- CCTV SYSTEM


101,200

Total SH 02 - SURVEILLANCE & SECURITY


4,061,500

659
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-02 SURVILLANCE & SECURITY:

SH-02A CCTV SYSTEM

Supply, Installation testing and Commissioning of IP Fixed indoor verifocal


lences 3.5-8mm auto iris 520 TVL POE camera including including integrated
housing (dome type)connectors,D/N, WDR, 3-9mm VF Auto-Iris Lens, IR Cut
1.00 Filter, H.264 30FPS,,Lens,camera mount and an ancillary Equipment & All
accessories complete as required. Make- Dv tel Model No- CM-4221-00 or
equivalent Nos 10.00 29,700.00 297,000
-
Supply and surface laying of 2CX1.5 sq mm power cable in existing 25 mm
2.00 dia PVC conduit.
Nos 450.00 50.00 22,500
-
Supply and laying of CAT 6 cable for communication in existing 25mm PVC
3.00 conduit.
Nos 700.00 41.00 28,700
-
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
4.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.
-
-
25mm
DSR -
a
1.21.2
Metre 550.00 65.00 35,750
-
Supply and Laying of 8/16,1356/1520 mm multinode optical fibre cable in 16
5.00 SWG MS Conduit.
Nos 100.00 176.00 17,600

Total SH 02 A- CCTV SYSTEM


401,550

660
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

SH-02B ACCESS CONTROL SYSTEM

-
Supply and Laying of 8cx 0.5 sq mm screen sheilded cable in existing condiut
1.00 / cable tray as required . Make- Reputed
Nos 500.00 54.00 27,000
-
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
2.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.
-
-
DSR - 25mm
a
1.21.2 Metre 400.00 65.00 26,000

Total SH 02 B- CCTV SYSTEM


53,000

Total SH 02 - SURVEILLANCE & SECURITY


454,550

661
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
RESIDENTIAL BLOCK 1 &2

SURVILLANCE & SECURITY:


SH-02

CCTV SYSTEM
SH-02A

Supply, Installation testing and Commissioning of IP Fixed indoor verifocal


lences 3.5-8mm auto iris 520 TVL POE camera including including integrated
housing (dome type)connectors,D/N, WDR, 3-9mm VF Auto-Iris Lens, IR Cut
1.00 Filter, H.264 30FPS,,Lens,camera mount and an ancillary Equipment & All
accessories complete as required. Make- Dv tel Model No- CM-4221-00 or
equivalent
Nos 13.0 29,700.0 386,100
-
Supply and surface laying of 2CX1.5 sq mm power cable in existing 25 mm
2.00 dia PVC conduit.
Nos 550.0 50.0 27,500
-
Supply and laying of CAT 6 cable for communication in existing 25mm PVC
3.00 conduit.
Nos 800.0 41.0 32,800
-
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
4.00 DSR - 1.21
conduit,or cutting the wall and making good the same in case of recessed
conduit as required. -
-
DSR - 25mm
a
1.21.2 Metre 800.0 65.0 52,000
-
Supply and Laying of 8/16,1356/1520 mm multinode optical fibre cable in 16
5.00 SWG MS Conduit. Nos 200.0 176.0 35,200

Total SH 02 A- CCTV SYSTEM


533,600

662
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
SH-02B ACCESS CONTROL SYSTEM

-
Supply and Laying of 8cx 0.5 sq mm screen sheilded cable in existing condiut
1.00 / cable tray as required . Make- Reputed
Nos 500.0 54.0 27,000
-
Supplying and fixing of following sizes of medium class PVC conduits along
with accessories in surface/ recess including painting in case of surface
2.00 DSR - 1.21 conduit,or cutting the wall and making good the same in case of recessed
conduit as required.
-
-
25mm
DSR -
a
1.21.2
Metre 400.0 65.0 26,000
-
Total SH 02 B- ACCESS CONTROL SYSTEM
53,000

Total SH 02 - SURVEILLANCE & SECURITY


586,600

663
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

10 ESTIMATED COST OF LIFTS

HEAD ESTIMATED
S. NO.
AMOUNT IN INR

10.01 SUMMARY OF COST (ACADEMIC & ADMIN BLOCK) 14,886,900

10.02 SUMMARY OF COST (HOSTEL BLOCK) 10,046,520

10.03 SUMMARY OF COST (RESIDENCE TYPE -1 & 2) 5,480,640

10.04 SUMMARY OF COST (RESIDENCE TYPE -3 & 4) 10,046,520

TOTAL 40,460,580

664
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATED COST OF LIFTS (ACADEMIC & ADMIN BLOCK)

LIFTS
SH-03

Design, manufacture, supply,transportation, installation, testing,


commissioning, approvals (All local/ State/ Central statutory bodies) and
handing over in satisfactory working conditions of Elevators meeting in all
respects the intents of specifications & drawings complete with a)
Scaffolding & minor civil, mechanical and electrical works b) Steel items with
directional control of cars (as required) with ACVVVF control with scratch
proof -textured stainless steel sheet enclosures, automatic centre opening
car & landing doors, hard wood flooring with 25mm recess including the cost
of providing 2 weeks satisfactory trial operation and testing at full design
load and safely checks for sudden breaks, speed, etc. as directed and
including the cost of providing free comprehensive maintenance service
during Defect Liability Period of 12 months after Virtual completion and
satisfactory handingover, complete as per specifications as required and as
below:
Note: All the passanger elevators shall be with vision panel of size 200x300mm
on CAR and lobby doors.

1.00 PASSENGER LIFTS (MACHINE ROOM LESS) (ADMIN BLOCK - CRYSTAL DOME)
(Five Glass Panels On Rear Side)

Machine Room Less (MRL) traction elevator in Shaft of dimensions 2000 mm x


2000 mm (W x D) for minimum payload carrying capacity of 8 passenger/
630 kg having a travel speed of 1.5 metre/ sec and travel height of 25.0
Mtrs. (approx.) with 6 Stops and Microprocessor based control suitable for
operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per
specifications.
No. 1.00 2,420,190.00 2,420,190

665
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
2.00 PASSENGER LIFTS ( MACHINE ROOM LESS) (ADMIN BLOCK - TYPE - Lift & Right)

Machine Room Less (MRL) traction elevator in Shaft of dimensions 1900 mm x


2000 mm (W x D) for minimum payload carrying capacity of 11 passenger/
748 kg having a travel speed of 1.5 metre/ sec and travel height of 30.50
Mtrs. (approx.) with 6 Stops and Microprocessor based control suitable for
operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per
specifications.

No. 4.00 2,511,630.00 10,046,520

3.00 PASSENGER LIFTS ( MACHINE ROOM LESS) (ADMIN BLOCK - CRYSTAL DOME)
(Five Glass Panels On Rear Side)

Machine Room Less (MRL) traction elevator in Shaft of dimensions 2000 mm x


2000 mm (W x D) for minimum payload carrying capacity of 8 passenger/
630 kg having a travel speed of 1.5 metre/ sec and travel height of 25.0
Mtrs. (approx.) with 6 Stops and Microprocessor based control suitable for
operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per
specifications.

No. 1.00 2,420,190.00 2,420,190

Total SH 03- LIFTS


14,886,900

666
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATED COST OF LIFTS (HOSTEL BLOCK)
SH-03 LIFTS

Design, manufacture, supply,transportation, installation, testing,


commissioning, approvals (All local/ State/ Central statutory bodies) and
handing over in satisfactory working conditions of Elevators meeting in all
respects the intents of specifications & drawings complete with a)
Scaffolding & minor civil, mechanical and electrical works b) Steel items with
directional control of cars (as required) with ACVVVF control with scratch
proof -textured stainless steel sheet enclosures, automatic centre opening
car & landing doors, hard wood flooring with 25mm recess including the cost
of providing 2 weeks satisfactory trial operation and testing at full design
load and safely checks for sudden breaks, speed, etc. as directed and
including the cost of providing free comprehensive maintenance service
during Defect Liability Period of 12 months after Virtual completion and
satisfactory handingover, complete as per specifications as required and as
below:
Note: All the passanger elevators shall be with vision panel of size 200x300mm
on CAR and lobby doors.

PASSENGER LIFTS ( MACHINE ROOM LESS) (HOSTEL BLOCK)


A
Machine Room Less (MRL) traction elevator in Shaft of dimensions 1900 mm x
2000 mm (W x D) for minimum payload carrying capacity of 11 passenger/
748 kg having a travel speed of 1.5 metre/ sec and travel height of 65.0
Mtrs. (approx.) with 19 Stops and Microprocessor based control suitable for
1.00 operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per
specifications.

No. 4.0 2,511,630.0 10,046,520

Total SH 03- LIFTS


10,046,520

667
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
ESTIMATED COST OF LIFTS (RESIDENCE TYPE -1 & 2)

SH-03 LIFTS
Design, manufacture, supply,transportation, installation, testing,
commissioning, approvals (All local/ State/ Central statutory bodies) and
handing over in satisfactory working conditions of Elevators meeting in all
respects the intents of specifications & drawings complete with a)
Scaffolding & minor civil, mechanical and electrical works b) Steel items with
directional control of cars (as required) with ACVVVF control with scratch
proof -textured stainless steel sheet enclosures, automatic centre opening
car & landing doors, hard wood flooring with 25mm recess including the cost
of providing 2 weeks satisfactory trial operation and testing at full design
load and safely checks for sudden breaks, speed, etc. as directed and
including the cost of providing free comprehensive maintenance service
during Defect Liability Period of 12 months after Virtual completion and
satisfactory handingover, complete as per specifications as required and as
below:
Note: All the passanger elevators shall be with vision panel of size 200x300mm
on CAR and lobby doors.

PASSENGER LIFTS ( MACHINE ROOM LESS) (RESIDENTIAL BLOCK - TYPE - 1 & 2)


1.00

Machine Room Less (MRL) traction elevator in Shaft of dimensions 2000 mm x


2500 mm (W x D) for minimum payload carrying capacity of 14 passenger/
952 kg having a travel speed of 1.75 metre/ sec and travel height of 55.0
Mtrs. (approx.) with 16 Stops and Microprocessor based control suitable for
operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per
specifications. Nos. 2.0 2,740,320.0 5,480,640

Total SH 03- LIFTS 5,480,640

668
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

ESTIMATED COST OF LIFTS (RESIDENCE TYPE -3 & 4)

SH-03 LIFTS
Design, manufacture, supply,transportation, installation, testing,
commissioning, approvals (All local/ State/ Central statutory bodies) and
handing over in satisfactory working conditions of Elevators meeting in all
respects the intents of specifications & drawings complete with a)
Scaffolding & minor civil, mechanical and electrical works b) Steel items with
directional control of cars (as required) with ACVVVF control with scratch
proof -textured stainless steel sheet enclosures, automatic centre opening
car & landing doors, hard wood flooring with 25mm recess including the cost
of providing 2 weeks satisfactory trial operation and testing at full design
load and safely checks for sudden breaks, speed, etc. as directed and
including the cost of providing free comprehensive maintenance service
during Defect Liability Period of 12 months after Virtual completion and
satisfactory handingover, complete as per specifications as required and as
below:
Note: All the passanger elevators shall be with vision panel of size 200x300mm
on CAR and lobby doors.

PASSENGER LIFTS ( MACHINE ROOM LESS) (RESIDENTIAL BLOCK - TYPE - 3 & 4)

Machine Room Less (MRL) traction elevator in Shaft of dimensions 1900 mm x


2000 mm (W x D) for minimum payload carrying capacity of 11 passenger/
748 kg having a travel speed of 1.5 metre/ sec and travel height of 65.0
1.00 Mtrs. (approx.) with 19 Stops and Microprocessor based control suitable for
operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per
specifications.

No. 4.0 2,511,630.0 10,046,520

Total SH 03- LIFTS 10,046,520

669
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

11 ESTIMATED COST OF DISTRIBUTION TRANSFORMERS, RTCC, SERVO STABLIZER (3 Nos.)

S. NO. HEAD ESTIMATED


AMOUNT IN INR

11.00 ESTMATED COST 7,500,000

TOTAL 7,500,000

STIMATED COST OF DISTRIBUTION TRANSFORMERS, RTCC, SERVO STABLIZER

DISTRIBUTION TRANSFORMERS, RTCC, SERVO STABLIZER


SH -01

1.00 Design, manufacture, supply, installation, testing and commissioning at site of


2500 KVA, 33/0.433KV, 3 phase, 50 Hz, delta/star connected, outdoor type
transformer, oil immersed ONAN cooled, complete with all fittings such as oil
conservator, silica gel breather, thermometer, explosion vent, ON Load Tap
Changer, diagram & rating plate, oil temperature indicator, winding
MR temperature indicator and buccholtz relay with wiring upto marshalling box,
lifting lugs, first filling of oil, weather proof HT cable box, LT bus duct
disconnecting chamber minimum 8 mm thick non magnetic gland plate
etc including 10% extra oil in non returnable drum for topping up complete
as given below and as required.

Losses Shall be as per ECBC-2007 (Amended Up to Date)

Space provision for CTs of differential /REF protection shall be provided (CTs
shall be provided loose as free issue item)

670
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Voltage Ratio : 33/0.433V

Vector Group : Dyn11

Insulation Class : 'A'

Tap Range [ON Load] : + 5.0% to -15.0% step of 1.25%

Temp rise @ 50degC ambient

in winding by resistance : 55decC

Impedance : 6.25%

(without negative tolerance)

Terminal arrangement (HV) : 3C x 300 Sqmm 33kV

Terminal arrangement (LV) : 4000 A 4P Aluminum Bus Duct.

2500 KVA Transformer as described above


Nos. 3.0 1,840,000.0 5,520,000

2.00 Design, manufacture, supply, installation, testing and commissioning at site


AIR COOLED, ROLLING CONTACT TYPE L.T. SERVO VOLTAGE STABILIZER,
MR SUITABLE FOR INDOOR INSTALLATION, BALANCED SUPPLY AND UNBALANCED
LOAD, COPPER WOUND.

Losses Shall be as per ECBC-2007 (Amended Up to Date)

INPUT : 360 to 460 Volts, 3 Ph., 50 Hz.

OUTPUT : 415 V ±1%, 3 Ph., 50 Hz.

500 KVA LT Servo Stablizer as described above


Nos. 1.0 1,080,000.0 1,080,000

3.00 RTCC (Remote Tap Changer Control )Panel suitable for Remote Operation of
2500 KVA 33 KV Transformer complete with all accessories as required.
MR

671
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Remote Tap Changer Control Panel (RTCC) comparise the following and as
per technical specifications:

Supply, installation, testing and commissioning of RTCC panel shall be of


sheet steel cabinet for indoor installation, floor mounting type. The RTCC
panel shall be 4 SWG CRCA sheet, totally enclosed, completely dust and
vermin proof and shall be with hinged doors, Neoprene gasket and
padlocking arrangement. The general construction shall confirm to IS-8623-
1977 (part-I) for factory built assembled switchgear & control gear for
voltage upto and including 1100 V AC.

All panels and covers shall be properly fitted and square with the frame, and
holes in the panel correctly positioned. Fixing screws shall enter into holes
tapped into an adequate thickness of metal or provided with wing nuts. Self
threading screws shall not be used in the construction of RTCC panel. A base
channel of 75 mm x 40 mm x 5 mm thick shall be provided at the bottom for
floor mounted panel.

The following components shall be provided in the RTCC panel :


- Digital Tap Position Indicating Meter

- Raise/Lower Push Buttons for Remote Control of OLTC


- Tap Change in Progress Signal Lamp.
- Supply on Signal Lamp
- Local / Remote Control Indicating Lamps
- Panel illuminating lamp with door switch.
- Space Heater with Switch and Thermostat.
- Automatic Voltage Relay with Time Delay Element.
- Selectors switch for Auto/Manual Operation.
- Undrilled Gland Plate for Cable entry.
- Earthing Terminal
- Lifting Eyes Bolts.
Suitable potential free contacts shall be provided. Nos. 3.0 300,000.0 900,000

Total SH 01- DISTRIBUTION TRANSFORMERS 7,500,000

672
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

12 SILENT TYPE D.G. SET 1500 KVA -04NO., 750 KVA-01NO.


SH -02
1.00 Design , manufacturing ,testing at site and Supply, loading, unloading as
desired by Project Manager, testing and commissioning of 3 phase 415 volts
50 cycle per second, 1500 KVA Radiator Cooled DG Set (Silent Type)1500
RPM prime duty, radiator cooled Diesel Generator Sets. The engine shall be
completed with turbo charger, flywheel to suit flexible coupling with guard,
air cleaner, blower fan, heat exchanger, fuel pump, variable speed
electronic governor, fuel filter, lub oil filter and pump, primary water
NON-DSR circulating pumps, battery charger, 12/24 volt batteries of compatible
capacity, MS battery stand and instrument panel comprising of switch with
key, lub oil pressure gauge, battery charging voltmeter, safety control for low
lub oil pressure with tripping etc. The alternator shall be self excited, self
regulated, brushless and continuously rated at 0.8 P.F., 3 phase 415 volts, 50
cycle per second, 4 wire system and shall be provided with static excitation
unit.
Set 4.0 10,430,000.0 41,720,000

2.00 Design , manufacturing ,testing at site and Supply, loading, unloading as


desired by Project Manager, testing and commissioning of 3 phase 415 volts
50 cycle per second, 750 KVA Radiator Cooled DG Set (Silent Type) 1500 RPM
prime duty, radiator cooled Diesel Generator Sets. The engine shall be
completed with turbo charger, flywheel to suit flexible coupling with guard,
air cleaner, blower fan, heat exchanger, fuel pump, variable speed
electronic governor, fuel filter, lub oil filter and pump, primary water
NON-DSR circulating pumps, battery charger, 12/24 volt batteries of compatible
capacity, MS battery stand and instrument panel comprising of switch with
key, lub oil pressure gauge, battery charging voltmeter, safety control for low
lub oil pressure with tripping etc. The alternator shall be self excited, self
regulated, brushless and continuously rated at 0.8 P.F., 3 phase 415 volts, 50
cycle per second, 4 wire system and shall be provided with static excitation
unit.
Set 1.0 7,200,000.0 7,200,000

673
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Note :
DG Sets shall include one day fuel tank of capacity as per manufacturer Standard
for each D.G. set. The day fuel tank shall be fabricated out of 2 mm thick MS
sheets and shall include the cost of removable cover with locking arrangement,
the cost of painting, the cost of providing all the required appurtenances like inlet
& outlet connection, float valves, drain connection, mechanical oil level indicator
and low level/high level alarms and the cost of support arrangement etc. complete
as per specification and as required.

The D.G. sets shall be inclusive of but not limited to the following standard
accessories:

a) Fly Wheel to suit flexible/rigid coupling.


Fly wheel housing complete with starter gear ring and coupling.
b)

c) Fuel hoses.

d) Electronic Governor.

e) Air Cleaner with Vacuum Indicator.

f) Fuel and Lub Oil Filter.

g) By pass filter

h) Corrosion inhibitor coolant.

i) Fuel Pump .

j) Water Pump.

k) Lub Oil Pump.

l) Electric Starter 24 Volts DC.

m) Battery Charging Alternator with Built-in-regulator - 24 Volts, 30 Amps.

Residential Silencer including baffle plates and 75 mm thick LRB rock wool (64
n) Kg/m3 density) insulation clad with 26 SWG aluminum sheet cladding.

674
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
i) Expansion bellow fabricated out of SS sheet.
o)
ii) Flue pipe of required size from DG set flue outlet upto Silencer.

Safety Control against low lub oil pressure, over speed and high cooling
p) water temperature along with tripping.

Lub Oil Cooler.


q)

Vibration Damper.
r)

Anti Vibration Pads.


s)

Droop CT for the synchronization.


t)

Total SH 02- DG SETS AMOUNT ABSTRACT 48,920,000

675
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

13 BUILDING MANEGMENT SYSTEM WORKS:

Design, Supply, Installation, Testing, Commissioning & Handing over the Building
Management System (BMS) and allied systems as per specifications as below.

1.0 BMS Computer System: PC (Pentium i Core processor, 2GB RAM, 52X DVD Writer,
22" TFT Color monitor, 180GB HDD SATA, Microsoft Bus mouse with pad, Windows
XP / Windows 7 operating system, 104 Keybord, Expansion Bus with spare Slot, with
original license, protection & restore key, includes LAN Card, USB ports

MR No. 1 75,000 75,000

2.0 BMS System Software : Web Based Graphical Software meeeting the requirements
in the Given I/O Summary and technical specifications including configuration and
facility to create / provide the graphic mapping for all I/O Summary points , animate
the Graphics, Navigation between pages, display of logs, changing the time zones,
popup alarms, configurable password protection for Building Mgmt System as per
Specifications. Software shall be able to communicate with Lonworks, Bacnet,
Modbus devices simultaneously, with unlimited user & Point license capacity. Same
software can be utilized as programming / commissioning software of DDC, NAC etc

MR No. 1 449,280 449,280

3.0 Energy Analytics / Energy Auditing System Software : Web Based Graphical
Software meeeting the requirements in the Given I/O Summary and technical
specifications including configuration and facility to create / provide the graphic
mapping for points, animate the Graphics, configurable password protection for
Energy Auditing Software as per Specifications.

MR No. 1 196,708 196,708

676
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

Note:
All required Software with original license competent with BMS software)

4.0 BTL Listed Web Based Router / Network Area Controller for interfacing DDCs to PC
(should be capable of connecting to TCP/IP network) and must provide hardware
features as must provide the following hardware features as a minimum:
a) Two Ethernet Port -10 / 100 Mbps
b) One RS-485 port
c) One LONWORKS Interface Port - 78KB TP/FT-10
d) Battery Backup
e) Flash memory for long term data backup (If battery backup or flash memory is not
supplied, the controller must contain a hard disk with at least 1gigabyte storage
capacity)
f) Capable of Calendar functions.Scheduling, Trending.Alarm monitoring and routing,
Time synchronization.
g) BTL & UL Listed

MR Lot 1 1,173,736 1,173,736


5.0 Web Based Integrator for interfacing Modbus RTU Unit, Bacnet IP / MSTP, Open
Protocol Software Integration for following
MR
5.1 For 5 Nos. of Chillers on Bacnet / Modbus (20 I/O's per unit)
MR No. 1 457,912 457,912
5.2 For 17 no. Lifts Interface on Modbus RTU (10 I/O's per Lift)
MR No. 1 Included above

5.3 For 1 no Fire Alarm System Panel on BACnet IP / Modbus RTU (1500 I/O's per FAS)

MR No. 1 400,770 400,770


5.4 MR For 40 Nos. for LT Panels / Energy Meters on Modbus RTU No. 1 Included above

5.5 MR For Diesel Generator.- 4 Nos. on Modbus RTU No. 1 Included above

677
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
6.0 Automation stations / DDC Controller with I/O module etc., The controllers shall be
16 bit microprocessor based standalone and net workable type with real time clock.
The DDC's shall be capable of peer to peer communication without help of system
interface controller or PC. with locable MS mounting cabinets duly powder coated
connector strip, internal wiring and space to house controller & relays, connector
strip current transformer, MCB, internal wiring. (Contractor shall confirm his I/O
provision w.r.t requirement on basis of data point) on Lonworks

6.1 MR DDC Panel for Chiller Plant Room & HWG Lot 1 325,148 325,148

6.2 MR DDC Panel for AHUs Nos 40 61,500 2,460,000

6.3 DDC Panel for TFAs


MR Nos 15 61,500 922,500

6.4 DDC Panel for Liftwell Pressurization Fan


MR Lot 1 87,000 87,000

6.5 MR DDC Panel for Ventillation System Lot 1 1,044,000 1,044,000

6.6 MR DDC Panel for Fire Fighting System Lot 1 45,000 45,000

6.7 MR DDC Panel for Water Supply System Lot 1 107,500 107,500

6.8 MR DDC Panel for Electrical System & DG system Lot 1 325,100 325,100

Note:

a Provision of integration with any BMS system conforming to ASHRAE BACnet/IP or


MODBUS IP, OPC shall be provided by respective equipment manufacture.

678
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
B) Sensors and field devices

Supply, installation, testing, commissioning of necessary Input sensor


transmitters/transducers comprising the following:

1.0 Differential Pressure sensor for Chilled Water Header Range (0-5 Kg/cm2)
MR Nos. 7 31,900 223,300

2.0 MR Immersion Temp Sensor for CHW line Nos. 23 4,290 98,670

3.0 MR Outside Temp & Humidity Sensor Nos. 1 22,900 22,900

4.0 MR Water Level Switches for Water Tanks Nos. 15 10,500 157,500

5.0 MR Differential Switches for Water Pumps Nos. 19 17,500 332,500

6.0 MR DP Switch Air for Monitoring Blower, Fan & Filter Status Nos. 487 3,050 1,485,350

7.0 MR Duct Type Temp Sensor Nos. 125 1,600 200,000

8.0 MR Water Flow Switch Nos. 5 2,500 12,500

9.0 MR Pressure sensor for Water Header Range (0-5 Kg/cm2) Nos. 4 16,500 66,000

10.0 MR Duct Pressure Sensor Nos. 130 17,800 2,314,000

11.0 MR Ultrasonic Water Flow Meter for CHW Supply & Return Header Nos. 2 450,000 900,000

12.0 MR Flame Proof Level Transmitter for Bulk & Day Oil tanks Nos. 5 16,000 80,000

13.0 MR Flame Proof Flow Meters for Diesel - 75 mm Nos. 2 95,000 190,000

14.0 MR Flame Proof Flow Meters for Diesel - 25 mm Nos. 4 75,000 300,000

679
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
C) Conduiting , Wiring and cabling

1.0 Supply, installation, testing and commissioning of following cables:

1.1 MR 2 Core 1.0 Sqmm, FR PVC Insulated, PVC sheathed ATC conductor multistranded,
Lead Free Signal Cable
RM 52,000 56 2,912,000

1.2 MR 3 Core 1.5 Sqmm, FR PVC Insulated, PVC Sheathed ATC conductor multistranded,
cable for Powering DDC , Actuators, Lead Free
RM 5,000 70 350,000

1.3 MR 2 Core 1.5 Sqmm, FR PVC Insulated, PVC Sheathed ATC conductor multistranded,
twisted & Shielded (Aluminium foil) cable, for communication Lead Free
Communication Cable
RM 11,500 70 805,000

1.4 MR Cat6e Cable RM 2,500 36 90,000

1.5 Supplying and laying of following sizes of ISI Mark 1.6 mm thick PVC conduit on
surface/recess including cutting/filling chases along with conduit accessories etc.
complete as required.

a) MR 25 mm dia
RM 28,000 84 2,352,000

b) MR Steel reinforced PVC quoated flexible pipe with all coupler & Clamps
RM 8,000 100 800,000

TOTAL CARRIED OVER TO ABSTRACT


21,761,374

680
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

14 SOLAR HOT WATER GENERATION SYSTEM (WITHOUT ELECTRICAL BACKUP)

FOR RESIDENTIAL BLOCK (TYPE 1 & 2)


1 -
Supply, Installation, Testing & Commissioning of 1500 LPD Evacuated Tube
Collector (ETC) based Solar Water Heating System comprising of evacuated
tubes, internal piping complete in all respects as per approved specifications
with insulated hot water storage tank, valves on inlet & outlet, Y strainer and
all necessary valves, temperature gauge, accessories, control and indication
equipment fittings to produce hot water at 60 deg C. Details of each item Set 1 292690 292,690
mentioned below: (Design & Shop Drawings of the entire system to be
approved)

a)
Solar Evacuated Tube Collectors (ETC) Industrial Type as per tube details given
below:-
- Outer diameter: 47 mm (+/-1mm)
- Inner Diameter: 37 mm (+/-1mm)
- Wall thickness: 1.5 mm (+/-0.2mm)
b) - Length: 1500 mm
- Bend Degree: 4/1000
- Vacuum Degree: 5x10-3 Pa
- Heat loss coefficient (K value): <0.90 Watt/ M2 0C 550 nos.

c)
Solar hot water storage tank capacity of 1500 liter made up of SS-304L thickness 1.6
mm with 100 mm rock wool insulation covered with chicken mesh and 22 SWG
aluminum cladding.
d)

681
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
e)
M.S. channel Stand for Hot Water Storage Tank including all necessary foundations
as per site.
f)

g)
Inter-connected G.I. 'C' Class System piping of 15, 20, 25, 32 & 40 mm with GI fittings
and insulated with 50mm thick Glass wool / Rock wool insulation covered with
chicken mesh and aluminum cladding. Piping should be inclusive of all accessories &
fittings. - 1 Lot.

a) Temperature Gauge - 1 No.

b) Ball Valve size 25 NB - 2 Nos.

c) NRV size 25 NB - 1 No.

d) CI Y Strainer 25 NB - 1 No.

Note:- Control Valves/ Mountings (Consisting of all ball valves, Non-Return Valves, Y
Strainers, Pressure release Valves, Pressure Gauges, Temperature gauge, Air Release
Valves and all other accessories required to complete the system)

Wire Mesh of 10 SWG fitted with M.S frame of 35x35x3 mm for proper support and
fitted with the help of clamp to protect from Monkeys, Heavy storm etc. gap of wire
mesh is 25x25 mm.

Civil work for grouting of the system. - 1 Lot

682
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.

FOR RESIDENTIAL BLOCK (TYPE 3 & 4)


-
Supply, Installation, Testing & Commissioning of 2500 LPD Evacuated Tube
Collector (ETC) based Solar Water Heating System comprising of evacuated
tubes, internal piping complete in all respects as per approved specifications
with insulated hot water storage tank, valves on inlet & outlet, Y strainer and
all necessary valves, temperature gauge, accessories, control and indication
equipment fittings to produce hot water at 60 deg C. Details of each item Set 1 483000 483,000
mentioned below: (Design & Shop Drawings of the entire system to be
approved)

Solar Evacuated Tube Collectors (ETC) Industrial Type as per tube details given
below:-
- Outer diameter: 47 mm (+/-1mm)
- Inner Diameter: 37 mm (+/-1mm)
- Wall thickness: 1.5 mm (+/-0.2mm)
- Length: 1500 mm
- Bend Degree: 4/1000
- Vacuum Degree: 5x10-3 Pa
- Heat loss coefficient (K value): <0.90 Watt/ M2 0C 550 nos.

Solar hot water storage tank capacity of 2500 liter made up of SS-304L thickness 2
mm with 100 mm rock wool insulation covered with chicken mesh and 22 SWG
aluminum cladding.

M.S. channel Stand for Hot Water Storage Tank including all necessary foundations
as per site.

683
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Inter-connected G.I. 'C' Class System piping of 15, 20, 25, 32 & 40 mm with GI fittings
and insulated with 50mm thick Glass wool / Rock wool insulation covered with
chicken mesh and aluminum cladding. Piping should be inclusive of all accessories &
fittings. - 1 Lot.

a) Temperature Gauge - 1 No.

b) Ball Valve size 25 NB - 2 Nos.

c) NRV size 25 NB - 1 No.

d) CI Y Strainer 25 NB - 1 No.

Note:- Control Valves/ Mountings (Consisting of all ball valves, Non-Return Valves, Y
Strainers, Pressure release Valves, Pressure Gauges, Temperature gauge, Air Release
Valves and all other accessories required to complete the system)

Wire Mesh of 10 SWG fitted with M.S frame of 35x35x3 mm for proper support and
fitted with the help of clamp to protect from Monkeys, Heavy storm etc. gap of wire
mesh is 25x25 mm.

Civil work for grouting of the system. - 1 Lot

684
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
HOSTEL & DINING BLOCK -
Supply, Installation, Testing & Commissioning of 2100 LPD Evacuated Tube
Collector (ETC) based Solar Water Heating System comprising of evacuated
tubes, internal piping complete in all respects as per approved specifications
with insulated hot water storage tank, valves on inlet & outlet, Y strainer and
all necessary valves, temperature gauge, accessories, control and indication
equipment fittings to produce hot water at 60 deg C. Details of each item Set 1 405570 405,570
mentioned below: (Design & Shop Drawings of the entire system to be
approved)

Solar Evacuated Tube Collectors (ETC) Industrial Type as per tube details given
below:-
- Outer diameter: 47 mm (+/-1mm)
- Inner Diameter: 37 mm (+/-1mm)
- Wall thickness: 1.5 mm (+/-0.2mm)
- Length: 1500 mm
- Bend Degree: 4/1000
- Vacuum Degree: 5x10-3 Pa
- Heat loss coefficient (K value): <0.90 Watt/ M2 0C 550 nos.

Solar hot water storage tank capacity of 2100 liter made up of SS-304L thickness 2
mm with 100 mm rock wool insulation covered with chicken mesh and 22 SWG
aluminum cladding.

M.S. channel Stand for Hot Water Storage Tank including all necessary foundations
as per site.

685
S.No. Dept. item code Description of item Unit Quantity Estimate Rate Amount Rs.
no. (UPPWD SOR,
CPWD DSR 2014
& NS) Rs.
Inter-connected G.I. 'C' Class System piping of 15, 20, 25, 32 & 40 mm with GI fittings
and insulated with 50mm thick Glass wool / Rock wool insulation covered with
chicken mesh and aluminum cladding. Piping should be inclusive of all accessories &
fittings. - 1 Lot.

a) Temperature Gauge - 1 No.

b) Ball Valve size 25 NB - 2 Nos.

c) NRV size 25 NB - 1 No.

d) CI Y Strainer 25 NB - 1 No.

Note:- Control Valves/ Mountings (Consisting of all ball valves, Non-Return Valves, Y
Strainers, Pressure release Valves, Pressure Gauges, Temperature gauge, Air Release
Valves and all other accessories required to complete the system)

Wire Mesh of 10 SWG fitted with M.S frame of 35x35x3 mm for proper support and
fitted with the help of clamp to protect from Monkeys, Heavy storm etc. gap of wire
mesh is 25x25 mm.

Civil work for grouting of the system. - 1 Lot

-
TOTAL CARRIED OVER TO ABSTRACT 1,181,260

686