SIGMA
Advanced Generator Protection
and Control
Marine approval
The S6000 is designed to comply with
marine requirements. The design of the
circuitry and metal casing provides the
best possible protection from EMC and
environmental stress.
• 3 phase measurements delay and relay functions. The protec- The S6000 has been thoroughly tested at
• Short circuit protection tion works on all three phases. A dedi- an independent accredited laboratory
• Over current protection cated LED and open collector output is with regards to very high vibration
• Overload protection provided for each protection function. levels, heat, cold, humidity, salt mist,
• Reverse power protection EMC emission and immunity as well as
• Excitation loss protection Load shedding can be done at two other parameters.
• Load shedding (2 levels) individual levels. Each level controls a
• 3 analogue outputs dedicated built-in relay.
• RS485 MODBUS slave Measured and calculated parameters
• CAN Bus can be provided as V DC and mA
• Redundant supply signals on three isolated analogue
outputs. The span of each output is
The S6000 IO/P Module provides data programmable.
acquisition and complete protection for
a single generator.
Interfacing
The S6000 measures the voltages across The RS485 MODBUS-RTU connection
all three phases as well as the current provides easy interfacing to SCADA
running through each phase. The vol- systems and PLCs. Measured and
tage and current signals are digitally calculated parameters are easily
sampled by the built-in signal processor accessed by any device capable of
and converted to true RMS values. operating as a MODBUS master.
Configuration parameters can also be
The S6000 will continuously do real-time accessed and altered through MODBUS-
calculations of voltage, current, fre- RTU.
quency, active/reactive power, VA,
power factor etc. The S6000 can connect An RS232 connection is provided for
to generators with or without neutral. point-to-point configuration. The S6000
can be remotely configured by “clear
text” commands issued from an ANSI
Protection standard terminal application (e.g. MS
The S6000 includes six programmable Windows HyperTerminal).
protection functions: Short Circuit, Over
Current, Reverse Power, Overload, The complete configuration can be
Excitation Loss and Voltage stored as a text file. This text file can be
Establishment. inspected or changed (see figure 2), and
later the (corrected) text file can be
The protection functions can be reloaded in an IO/P Module. Fig. 2. Configuration of the SIGMA IO/P Module
in text format.
configured with regards to trip level,
SIGMA S6100 S/LS Module lization, voltage stabilization, automatic
synchronization and active/reactive
load sharing. The PID algorithms pro-
vide very fast regulation with very little
overshoot.
Interfacing
The RS485 MODBUS-RTU connection
provides easy interfacing to SCADA
systems and PLCs. Measured and calcu-
lated parameters are easily accessed by
any device capable of operating as a
MODBUS master. Configuration para-
meters can also be accessed and altered
through MODBUS-RTU.
• Integrated multimeter
• SIGMA user interface
• SIGMA remote control
• C/B status
• CAN bus
• Pin code protected SHAFT GENERATOR
(GRID)
• Redundant supply
Next S6100
Frequency Control
minal. The S6500 will provide real-time Sync On
Marine approval
As for the S6000/S6100 the S6500 is
designed to fully comply with marine
requirements.
Next S6000 / S6100
Application: Synchronizing
between Busbars
A unique feature of the SIGMA system
is the possibility of simultaneous syn-
chronization of already parallel running
generators to another busbar section, a
shaft generator or the grid. This feature
is shown in the diagram in figure 3.
An output (FREQ. OUT) from the Fig. 3. Application diagram. Synchronizing parallel running generators to a shaft generator (grid).
SIGMA S6610 Power Manager Module
• Full featured Power Manager The cyclic sequence starts and stops the
Σ SIGMA
• Load depending start and stop generators according to the assigned
• 5 large consumer requests priority. The highest (numerical lowest)
• 5 non essential load trips prioritized generator is the first to be
• Blackout clearance started, then the second highest, etc. Gen. Page
ENGINE ERROR
the generator with the largest number of
No
The S6610 PM Module provides power running hours is the first to be stopped. Duty
Reset Test
management functionality to the SIGMA PWR1 PWR2 ALARM
Primarily the products are used for generators on board ships and in compact land-
based power stations where operation in parallel with the grid (utility) may also be a
requirement.
SELCO also manufactures a wide range of alarm monitors, indicator panels and soft-
ware for use in a broad variety of marine and industrial applications, e.g. pharmaceuti-
cal industry, food processing, petrochemical industry, machinery, off shore and energy
distribution. All products undergo thorough test and inspection procedures to ensure
high reliability and continuous operation in the field.
SELCO staff and its partners worldwide take pride in exceeding the customers’
expectations in quality and excellent service.
Denmark
Betonvej 10
SELCO A/S
Main Office:
www.selco.com
SELCO Denmark
SELCO subsidiary
SELCO representation
has
SELCO Worldwide
Ge et
rue
Fax: + 45 - 70 26 25 22
Phone: + 45 - 70 26 11 22
ner RM
ato Sm
Ge
e
e-mail: selco.dk@selco.com
ner r Sho
ato rt C asure
Ge rO i r c me
ner ver u it nts
Ge
ato C urr
Pro
ner r Ove ent tectio
Ge
ato rlo
ad Pro n
n. E r Rev
ers P r o
tec
t ion
xci tec
Ge t eP tio
n. U ation ow
e n
nd Lo
x x x x x x x x
Lo er/ ss P r Pro
ad
Specifications
Ov ro tec
Bu
She e r V tectio tion
s U d d i ng
nd
olt
a n
Bu er/ , 2 lev ge
sU Ov els
nd er
Bu er/ Vo
sF O ltag
req ver e
Fre uen Fre
qu
enc c y qu
enc
De
Vo via y
ltag y Sta
b tio
De
eS
tab i l i s a
n (d
ad f/d
Bu ilisa tion t)
tio
Au
to
sC
los n
Syn ure
Vo
ltag chron
eM izin
Ac
tive atch g
i ng
Rea Load
cti Sha
ve r i ng
Un Lo
loa a
d w d Sha
Pow it h r
er aut ing
Us M ana o m
er atic
Inte gem
Lo
ad r face
ent trip
De /M
Lar pe ult
ge nd
Co in ime
Co nsu g Star ter
ntr t/
ol f mer H S
Co or and top
ntr Co l i ng
ol f nve
Co or ntio
ntr Ele nal
ol f ctr G
Co or on
ntr Co ic G over
ol f nve ove no
Pro o ntio rno rs
tec r Elec n a r s
On tion F tronic l AVR
site aul AV s
t
S6600 x x x x x x x
x x x x x x x x x x x x x x x x x
Co Rs
S6500 x x x x
list
RS
48 nfi s
5 M gura
OD tio
BU nP
ane
SS
lav l
e
Q1005-72E