You are on page 1of 2

参考

N E W 資料

Simple, Flexible and Reliable!

VA-5000 series
Multi-Component Gas Analyzer
●Sample screen

Flexibility for various applications

・Wide selection of measurement ranges.


・Broad variety of components and flexible combinations,
up to 4 measurement components (e.g. NDIR + Galvanic cell).
・O2 correction can be done by equipped calculation function.

Simple integration 【Measurement】

・Plug and Play function for easy replacement and upgrades.


・Auto calibration and blowback control are available.
・Ability to receive external signal and display it on analyzer`s
screen (up to 4 external signals).
・Sequential or parallel measurement of sample gas via special
separate gas inlets.

User friendly display and easy operation 【Auto Calibration Setting】

・Real time analysis by the color trend graph on 5.7 inch


LCD touch screen.
・Compact size: 430mm(W)×380mm(D)×132mm(H).
・Standard communication protocol MODBUSTM TCP/IP,
optional - analog input/output and digital input/output.
・USB data logging enables data saving for more than 15 days.
*Modbus is a trademark of Schneider Electric Inc.

【Concentration Alarm Setting】


Coming soon!!
★ Release on January 1, 2017
・Additional components for VA-5000
Ranges Range
Comp. Detector
Minimum Maximum ratio
SO2 NDIR 0-200 ppm 0-10 vol% 1:10
NH3 NDIR 0-100 ppm 0-1000 ppm 1:10
NO CLD 0-20 ppm 0-5000 ppm 1:100
NOx CLD 0-20 ppm 0-5000 ppm 1:100
O2 MPA 0-5 vol% 0-100 vol% 1:10
・Sampling System VS-5000 【Trend graph】
■ Specifications
Component NO CO CO2 N2O CH4 O2
Measurement principle NDIR Galvanic Cell Zirconia
Combination Max. 4 measurement components (In combination with Zirconia max. 3 components)
Min. range 200ppm 100ppm 200ppm
500ppm 100ppm 5vol%
Range (Special) (50/100 ppm) (50ppm) (100ppm)
Max. range 1vol% 100vol% 100vol% 5000ppm 100vol% 25vol%
Number of range Max. 5
Standard 1:10 1:5
Range ratio
Special 1:20 -
Zero
Repeatability ±0.5% of F.S.
Span
±1.0% of F.S.
Linearity ±1.0% of F.S.
±2.0% of F.S. (range ratio 1:20 or extended range)
±2.0%/week of F.S. (except for below range)
Zero ±2.0%/day (CO: 50ppm, CO2: 50ppm) ±1.0%/week
Performance ±1.0%/day (CO: 100ppm, CH4: 100ppm) ±1.0%/day
of F.S.
Drift of F.S.
±2.0%/week of F.S. (except for below range)
Span ±2.0%/day (CO: 50ppm, CO2: 50ppm) ±2.0%/week
±1.0%/day (CO: 100ppm, CH4: 100ppm) of F.S.

Response time
30 sec. (T90), 40 sec (Td+T90); single component (flow rate 0.5L/min.)
(from analyzer inlet)
Warm-up time 60 min. 40 min. 20 min.
Standard Ethernet (ModbusTM TCP/IP), USB port
Analog Input Max. 4ch, 0-16mA/4-20mA/0-20mA or 0-1V isolated
Max. 8ch: 0-16mA/4-20mA/0-20mA or 0-1V isolated, Current output: load resistance< 750Ω,
Analog Output
Input/Output voltage output: Input impedance> 100kΩ
Special
Max. 16ch isolated, open voltage: 24V, Short-circuit current: 10mA
Digital Input
Max. load resistance: < 50Ω Min. pulse width: 0.5 Sec.
Digital Output Max. 16 ch isolated, Max. voltage: DC 30V, Max. current: 1A, Min. voltage: DC 0.1V, Min. current: 0.1A
Standard 0.5L/min. ±0.2L/min.
Flow rate
Special 1.0L/min. ±0.2L/min. (selectable when all components are NDIR) -
Measuring Sample condition Ambient temperature, Dust free, H2O less than 5℃(41℉) saturation, Pressure: 0 to 5 kPa
gas condition Inlet and outlet - 6mm/4mm PTFE; a single gas inlet is provided standard; the gas flows sequentially from one module to the next;
Gas connections
as an option separate gas inlets can be provided for each module.
Gas Tubing PTFE; Stainless steel optional
Installation condition Temperature: 0-45℃ (32-113℉), Humidity: 90% (not condensed)
Altitude: Max. 3000m (approx. 9800ft) for NDIR, Max. 2000m (approx. 6500ft) for Galvanic cell and zirconia
Power supply 100-240V AC (±10%, max. voltage 250VAC), 50/60 Hz (±1.0%)
Power consumption Max. 315 VA
Display 5.7" Color LCD
Exterior dimensions 430mm (W) x 380mm (D) x 132mm (H), 19in panel mount (approx. 17in (W) x 15in (D) x 5.2in (H))
Mass Approx. 7 - 18kg (approx. 15 - 40lb)

The HORIBA Group adopts IMS (Integrated Management System) which integrates Quality Management System ISO9001, Environmental Management System ISO14001,
and Occupational Health and Safety Management System OHSAS18001.
We have now integrated Business Continuity Management System ISO22301 in order to provide our products and services in a stable manner, even in emergencies.

Please read the operation manual before using this product to assure safe and proper handling of the product.

●The specifications, appearance or other aspects of products in this catalog are subject to change without notice.
●Please contact us with enquiries concerning further details on the products in this catalog.
●The color of the actual products may differ from the color pictured in this catalog due to printing limitations.
●It is strictly forbidden to copy the content of this catalog in part or in full.
●The screen displays shown on products in this catalog have been inserted into the photographs through compositing.
●All brand names, product names and service names in this catalog are trademarks or registered trademarks of their respective companies.

http://www.horiba.com

HORIBA, Ltd. Japan HORIBA (Thailand) Ltd. Thailand HORIBA Instruments Brazil, Ltda. Brazil
Head Office East Office Head Office
2 Miyanohigashi, Kisshoin, Minami-ku, Kyoto, Japan 850 / 7 Soi Lat Krabang 30 / 5, Lat Krabang Road, Lat Krabang, Rua:Presbitero Plinio Alves de Souza, 645, Loteamento
Phone: 81 (75) 313-8121 Fax: 81 (75) 321-5725 Bangkok 10520, Thailand Polo Multivias Barirro Medeiros-Jundiai Sao Paulo
Phone: 66 (0) 2734 4434 Fax: 66 (0) 2734 4438 CEP 13.212-181 Brazil
HORIBA (China) Trading Co., Ltd. China Phone: 55 (11) 2923-5400 Fax: 55 (11) 2923-5490
Shanghai PT HORIBA Indonesia Indonesia
Unit D, 1F, Building A, Synnex International Park, 1068 West Jl. Jalur Sutera Blok 20A, No.16-17, Kel. Kunciran, Kec. Pinang HORIBA France Sarl France
Tianshan Road, Shanghai, 200335, China Tangerang-15144, Indonesia 12. Av des Tropiques Hightec Sud, F-91955 Les Ulis, France
Phone: 86 (21) 6289-6060 Fax: 86 (21) 6289-5553 Phone: 62 (21) 3044-8525 Fax: 62 (21) 3044-8521 Phone: 33 (1) 69-29-96-23 Fax: 33 (1) 69-29-95-77
Beijing
12F, Metropolis Tower, No.2, Haidian Dong 3 Street, Beijing, HORIBA India Private Limited India HORIBA UK Limited UK
100080, China Delhi Northampton
Phone: 86 (10) 8567-9966 Fax: 86 (10) 8567-9066 246, Okhla Industrial Estate, Phase 3 New Delhi-110020, India Kyoto Close Moulton Park, Northampton NN3 6FL, UK
Phone: 91 (11) 4646-5000 Fax: 91 (11) 4646-5020 Phone: 44 (1604) 542-500 Fax: 44 (1604) 542-699
HORIBA Korea Ltd. Korea Pune
10, Dogok-Ro, 6-Gil, Gangnam-Gu, Seoul-Si, 06259, Korea 502, 5th Floor, Purushottam Plaza, Baner Road, Baner, HORIBA Europe GmbH Germany
Phone: 82 (2) 753-7911 Fax: 82 (2) 756-4972 Pune-411045 INDIA Head Office
Phone: 91 (20) 4076-6000 Fax: 91 (20) 4076-6010 Hans-Mess-Str.6 D-61440 Oberursel Germany
HORIBA Instruments (Singapore) Pte Ltd. Singapore Bangalore Phone: 49 (6172) 1396-0 Fax: 49 (6172) 1373-85
3 Changi Business Park Vista #01-01 Akzonobel House, No.55,12th Main,Behind BDA Complex,6th sector,HSR Layout, Leichlingen
Singapore 486051 Bangalore South,Bangalore - 560102, INDIA Julius-kronenberg Str.9 D-42799 Leichlingen Germany
Phone: 65 (6) 745-8300 Fax: 65 (6) 745-8155 Phone: 91 (80) 4127-3637 Phone: 49 (2175) 8978-0 Fax: 49 (2175) 8978-50

HORIBA Vietnam Co., Ltd. Vietnam HORIBA Instruments Inc. USA HORIBA Czech Czech
Unit 6, 10 Floor, CMC Tower, Duy Tan Street, Dich Vong Head Office Prumyslova 1306 / 7, CZ-10200, Praha 10, Czech Republic
Hau Ward, Cau Giay District, Hanoi, Vietnam 9755 Research Drive, Irvine, CA 92618, U.S.A. Phone: 420 (2) 460-392-65
Phone: 84 (4) 3795-8552 Fax: 84 (4) 3795-8553 Phone: 1 (949) 250-4811 Fax: 1 (949) 250-0924
Alvin, TX HORIBA (Austria) GmbH Austlia
5318 W.FM517 Rd, Alvin, TX 77511, U.S.A
Kaplanstrasse 5 A-3430 Tulln, Austria
Phone: 1 (281) 482- 4334 Fax: 1 (281) 614-0303
Phone: 43 (2272) 65225 Fax: 43 (2272) 65230

Bulletin:HRE-2885A Printed in Japan 1606SK00