Q [U.S.

GPM]
0 50 100 150 200 250 300 350 400
25,0
H H
1450 RPM
80
[m] [feet]
22,5
32-250 70
20,0 40-250 50-250 65-250
80-250
60
17,5

15,0 50
80-200
32-200
12,5 40-200 40
50-200 65-200
10,0
32-160 50-160 65-160 30

7,5 40-160
80-160
20
5,0

10
2,5

0 0
0 10 20 30 40 50 60 70 80 90 100

Flow rate Q [m3/h]

Q [U.S.GPM]
0 100 200 300 400 500 600 700 800
100
H H
2900 RPM

[m] [feet]
300
90
32-250

80 40-250 50-250 65-250 250


80-250
70

60 200
80-200
32-200
50 40-200
50-200 65-200 150
40
32-160 50-160 65-160
30 40-160 100
80-160

20
50
10

0 0
0 20 40 60 80 100 120 140 160 180 200

Flow rate Q [m3/h]

for handled Liquid with SG = 1000 kg/m3, Viscosity = MM2/s

Shanley Pump
50Hz Performance Curve & Equipment, Inc.
2525 S. Clearbrook Drive
Arlington Heights, IL 60005
P: (847) 439-9200
F: (847) 439-9388
Heat Transfer Pumps www.shanleypump.com
Heat transfer pumps with mechanical seal
Subject to technical modications and error.
Q [U.S.GPM]
0 50 100 150 200 250 300 350 400 450 550
35,0
H H
1750 RPM

[m] 32,5 [feet]


32-250
30,0 100
40-250 50-250 65-250
27,5
80-250
25,0
80
22,5
80-200
20,0
32-200
40-200 60
17,5
50-200 65-200
15,0
32-160 50-160 65-160
12,5 40
40-160
10,0 80-160
7,5
20
5,0

2,5

0 0
0 12,5 25,0 37,5 50,0 62,5 75,0 87,5 100,0 112,5 125,0

Flow rate Q [m3/h]

Q [U.S.GPM]
0 100 200 300 400 500 600 700 800 900
120
H H
3500 RPM

[m] [feet]
110
350
100
32-250
65-250 80-250
90
40-250 300
50-250
80
32-200 250
40-200 80-200
70
50-200
65-200
60 200
32-160
50-160 65-160
50
40-160 80-160 150
40

30 100

20
50
10

0 0
0 20 40 60 80 100 120 140 160 180 200 220

Flow rate Q [m3/h]

for handled Liquid with SG = 1000 kg/m3, Viscosity = MM2/s

Shanley Pump
60Hz Performance Curve & Equipment, Inc.
2525 S. Clearbrook Drive
Arlington Heights, IL 60005
P: (847) 439-9200
F: (847) 439-9388
Heat Transfer Pumps www.shanleypump.com
Heat transfer pumps with mechanical seal
Subject to technical modications and error.

You might also like