You are on page 1of 56

1,000 mm – cover width

5.1

KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 25 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 3.09 2.88 2.50 2.13 1.88 1.69 1.54 1.42 1.33 1.25 1.18 1.12 1.07 1.03 0.99 0.95 0.92 0.89 0.86 0.84
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 4.21 3.08 2.50 2.13 1.88 1.69 1.54 1.42 1.33 1.25 1.18 1.12 1.07 1.03 0.99 0.95 0.92 0.89 0.86 0.84
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 4.21 3.08 2.50 2.31 1.88 1.69 1.54 1.42 1.33 1.25 1.18 1.12 1.07 1.03 0.99 0.95 0.92 0.89 0.86 0.84
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 4.21 3.08 2.50 2.31 1.88 1.69 1.54 1.42 1.33 1.25 1.18 1.12 1.07 1.03 0.99 0.95 0.92 0.89 0.86 0.84
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 4.22 3.08 2.50 2.13 1.88 1.69 1.54 1.42 1.33 1.25 1.18 1.12 1.07 1.03 0.99 0.95 0.92 0.89 0.86 0.84
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

Load-span tables
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 4.22 3.08 2.50 2.13 1.88 1.69 1.54 1.42 1.33 1.25 1.18 1.12 1.07 1.03 0.99 0.95 0.92 0.89 0.86 0.84
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 4.22 3.08 2.50 2.13 1.88 1.69 1.54 1.42 1.33 1.25 1.18 1.12 1.07 1.03 0.99 0.95 0.92 0.89 0.86 0.84
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 25 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 2.86 2.46 2.31 2.19 2.10 1.95 1.78 1.64 1.52 1.43 1.35 1.28 1.22 1.16 1.12 1.07 1.04 1.00 0.97 0.94
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.81 3.74 2.94 2.48 2.17 1.95 1.78 1.64 1.52 1.43 1.35 1.28 1.22 1.16 1.12 1.07 1.04 1.00 0.97 0.94
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 5.81 3.74 2.94 2.48 2.17 1.95 1.78 1.64 1.52 1.43 1.35 1.28 1.22 1.16 1.12 1.07 1.04 1.00 0.97 0.94
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.81 3.74 2.94 2.48 2.17 1.95 1.78 1.64 1.52 1.43 1.35 1.28 1.22 1.16 1.12 1.07 1.04 1.00 0.97 0.94
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.30 3.74 2.94 2.48 2.17 1.95 1.78 1.64 1.52 1.43 1.35 1.28 1.22 1.16 1.12 1.07 1.04 1.00 0.97 0.94
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 5.30 3.74 2.94 2.48 2.17 1.95 1.78 1.64 1.52 1.43 1.35 1.28 1.22 1.16 1.12 1.07 1.04 1.00 0.97 0.94
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.30 3.74 2.94 2.48 2.17 1.95 1.78 1.64 1.52 1.43 1.35 1.28 1.22 1.16 1.12 1.07 1.04 1.00 0.97 0.94
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.2

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
1,000 mm – cover width
5.3

KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 40 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 3.84 3.45 3.04 2.54 2.20 1.94 1.75 1.59 1.47 1.37 1.28 1.21 1.15 1.10 1.05 1.01 0.97 0.94 0.91 088
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 4.93 3.55 2.87 2.45 2.17 1.94 1.75 1.59 1.47 1.37 1.28 1.21 1.15 1.10 1.05 1.01 0.97 0.94 0.91 0.88
60 60 60 60 60 60 60 60 60 60 60 60 60 60 63 65 66 68 69 71
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 4.93 3.55 2.87 2.45 2.17 1.94 1.75 1.59 1.47 1.37 1.28 1.21 1.15 1.10 1.05 1.01 0.97 0.94 0.91 0.88
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 63 65 66 68 69 71
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 4.93 3.55 2.87 2.45 2.17 1.94 1.75 1.59 1.47 1.37 1.28 1.21 1.15 1.10 1.05 1.01 0.97 0.94 0.91 0.88
60 60 60 60 60 60 60 60 60 60 60 60 60 60 63 65 66 68 69 71
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.30 3.82 3.04 2.54 2.20 1.94 1.75 1.59 1.47 1.37 1.28 1.21 1.15 1.10 1.05 1.01 0.97 0.94 0.91 0.88
60 60 60 60 60 60 60 60 60 60 60 60 60 62 63 65 66 68 69 71

Load-span tables
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 5.30 3.82 3.04 2.54 2.20 1.94 1.75 1.59 1.47 1.37 1.28 1.21 1.15 1.10 1.05 1.01 0.97 0.94 0.91 0.88
60 60 60 60 60 60 60 60 60 60 60 60 60 62 63 65 66 68 69 71
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.30 3.82 3.04 2.54 2.20 1.94 1.75 1.59 1.47 1.37 1.28 1.21 1.15 1.10 1.05 1.01 0.97 0.94 0.91 0.88
60 60 60 60 60 60 60 60 60 60 60 60 60 62 63 65 66 68 69 71

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 40 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 3.25 3.03 2.81 2.65 2.52 2.41 2.23 2.04 1.88 1.74 1.63 1.53 1.44 1.36 1.30 1.24 1.18 1.14 1.09 1.05
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 7.50 4.91 3.83 3.17 2.72 2.40 2.17 1.99 1.84 1.72 1.62 1.53 1.44 1.36 1.30 1.24 1.18 1.14 1.09 1.05
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 7.50 4.91 3.71 3.03 2.60 2.30 2.08 1.91 1.77 1.66 1.56 1.48 1.41 1.35 1.30 1.24 1.18 1.14 1.09 1.05
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 7.50 4.68 3.45 2.81 2.42 2.14 1.94 1.79 1.67 1.56 1.48 1.41 1.34 1.29 1.24 1.20 1.16 1.12 1.09 1.05
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 6.42 4.91 3.83 3.20 2.78 2.47 2.23 2.04 1.88 1.74 1.63 1.53 1.44 1.36 1.30 1.24 1.18 1.14 1.09 1.05
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 6.42 4.91 3.83 3.20 2.78 2.47 2.23 2.04 1.88 1.74 1.63 1.53 1.44 1.36 1.30 1.24 1.18 1.14 1.09 1.05
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 6.42 4.91 3.83 3.20 2.78 2.47 2.23 2.04 1.88 1.74 1.63 1.53 1.44 1.36 1.30 1.24 1.18 1.14 1.09 1.05
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.4

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
1,000 mm – cover width
5.5

KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 60 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 4.86 4.28 3.83 3.38 2.90 2.54 2.25 2.02 1.83 1.68 1.55 1.44 1.35 1.27 1.20 1.15 1.10 1.05 1.01 0.98
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.52 3.92 3.13 2.66 2.33 2.10 1.92 1.77 1.66 1.56 1.48 1.41 1.35 1.27 1.20 1.15 1.10 1.05 1.01 0.98
60 60 60 60 60 60 60 60 61 64 66 69 71 72 73 74 75 76 77 79
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 5.52 3.92 3.13 2.66 2.33 2.10 1.92 1.77 1.66 1.56 1.48 1.41 1.35 1.27 1.20 1.15 1.10 1.05 1.01 0.98
Span 60 60 60 60 60 60 60 60 61 64 66 69 71 72 73 74 75 76 77 79
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.52 3.92 3.13 2.66 2.33 2.10 1.92 1.77 1.66 1.56 1.48 1.41 1.35 1.27 1.20 1.15 1.10 1.05 1.01 0.98
60 60 60 60 60 60 60 60 61 64 66 69 71 72 73 74 75 76 77 79
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 6.34 4.49 3.57 3.02 2.64 2.37 2.16 2.00 1.83 1.68 1.55 1.44 1.35 1.27 1.20 1.15 1.10 1.05 1.01 0.98
60 60 60 60 60 60 63 66 68 69 69 70 71 72 73 74 75 76 77 79

Load-span tables
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 6.34 4.49 3.57 3.02 2.64 2.37 2.16 2.00 1.83 1.68 1.55 1.44 1.35 1.27 1.20 1.15 1.10 1.05 1.01 0.98
60 60 60 60 60 60 63 66 68 69 69 70 71 72 73 74 75 76 77 79
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 6.34 4.49 3.57 3.02 2.64 2.37 2.16 2.00 1.83 1.68 1.55 1.44 1.35 1.27 1.20 1.15 1.10 1.05 1.01 0.98
60 60 60 60 60 60 63 66 68 69 69 70 71 72 73 74 75 76 77 79

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 60 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 4.38 3.88 3.57 3.34 3.16 3.01 3.01 2.81 2.65 2.52 2.36 2.20 2.06 1.83 1.73 1.64 1.55 1.48 1.41 1.35
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 9.25 6.05 4.57 3.67 3.11 2.73 2.44 2.23 2.05 1.91 1.79 1.69 1.60 1.53 1.46 1.40 1.35 1.30 1.26 1.22
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 9.25 6.04 4.36 3.50 2.96 2.60 2.33 2.13 1.96 1.83 1.72 1.62 1.54 1.47 1.414 1.35 1.30 1.26 1.22 1.18
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 9.25 5.60 4.02 3.23 2.74 2.41 2.17 1.98 1.84 1.72 1.62 1.53 1.46 1.40 1.34 1.29 1.24 1.20 1.16 1.13
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 7.99 6.05 4.83 4.14 3.58 3.12 2.78 2.52 2.32 2.15 2.01 1.89 1.79 1.70 1.62 1.55 1.49 1.44 1.38 1.34
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 7.99 6.05 4.83 4.12 3.47 3.03 2.70 2.45 2.25 2.08 1.95 1.84 1.74 1.65 1.58 1.51 1.45 1.40 1.35 1.31
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 7.99 6.05 4.83 3.93 3.31 2.88 2.57 2.33 2.14 1.99 1.86 1.75 1.66 1.58 1.51 1.45 1.40 1.34 1.30 1.26
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.6

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
1,000 mm – cover width
5.7

KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 80 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 41 42 43 43 43 43 43 43 43 43 43 43 43 43 43
I, II, III (f) 5.88 5.08 4.55 4.18 3.67 3.23 2.87 2.56 2.31 2.10 1.92 1.76 1.63 1.52 1.42 1.34 1.26 1.20 1.14 1.10
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 41 42 43 44
I (f) 6.02 4.26 3.38 2.85 2.49 2.23 2.03 1.87 1.74 1.64 1.55 1.47 1.40 1.34 1.29 1.25 1.20 1.17 1.13 1.10
60 60 60 60 60 60 60 62 64 67 70 72 74 76 78 81 82 85 86 88
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 41 42 43 44
Double
II (f) 6.02 4.26 3.38 2.85 2.49 2.23 2.03 1.87 1.74 1.64 1.55 1.47 1.40 1.34 1.29 1.25 1.20 1.17 1.13 1.10
Span 60 60 60 60 60 60 60 62 64 67 70 72 74 76 78 81 82 85 86 88
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 41 42 43 44
III (f) 6.02 4.26 3.38 2.85 2.49 2.23 2.03 1.87 1.74 1.64 1.55 1.47 1.40 1.34 1.29 1.25 1.20 1.17 1.13 1.10
60 60 60 60 60 60 60 62 64 67 70 72 74 76 78 81 82 85 86 88
40 40 40 40 40 40 40 40 40 40 40 40 41 43 43 43 43 43 44 44
I (f) 6.90 4.85 3.84 3.22 2.80 2.50 2.27 2.09 1.95 1.82 1.72 1.64 1.56 1.50 1.42 1.34 1.26 1.20 1.14 1.10
60 60 60 60 60 60 66 69 72 75 77 80 82 85 86 86 86 87 87 88

Load-span tables
40 40 40 40 40 40 40 40 40 40 40 40 41 43 43 43 43 43 44 44
Multi Span II (f) 6.90 4.85 3.84 3.22 2.80 2.50 2.27 2.09 1.95 1.82 1.72 1.64 1.56 1.50 1.42 1.34 1.26 1.20 1.14 1.10
60 60 60 60 60 60 66 69 72 75 77 80 82 85 86 86 86 87 87 88
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 6.90 4.85 3.84 3.22 2.80 2.50 2.27 2.09 1.95 1.82 1.72 1.64 1.56 1.50 1.42 1.34 1.26 1.20 1.14 1.10
60 60 60 60 60 60 66 69 72 75 77 80 82 85 86 86 86 87 87 88

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 80 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 5.53 4.81 4.38 4.08 3.84 3.62 3.41 3.23 3.08 2.93 2.79 2.65 2.50 2.36 2.24 2.21 2.02 1.92 1.83 1.75
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 9.85 6.88 5.23 4.16 3.49 3.04 2.71 2.46 2.26 2.10 1.96 1.84 1.74 1.66 1.58 1.51 1.45 1.40 1.35 1.30
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 9.85 6.88 4.98 3.95 3.32 2.89 2.58 2.34 2.16 2.00 1.88 1.77 1.67 1.59 1.52 1.46 1.40 1.35 1.30 1.26
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 9.85 6.51 4.58 3.63 3.05 2.67 2.39 2.17 2.01 1.87 1.76 1.66 1.58 1.50 1.44 1.38 1.33 1.28 1.24 1.20
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 9.45 6.88 5.47 4.68 4.02 3.48 3.08 2.78 2.54 2.34 2.18 2.05 1.93 1.83 1.74 1.66 1.59 1.53 1.48 1.42
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 9.45 6.88 5.47 4.66 3.89 3.37 2.98 2.69 2.46 2.27 2.12 1.98 1.87 1.78 1.69 1.62 1.55 1.49 1.44 1.39
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 9.45 6.88 5.47 4.43 3.70 3.20 2.83 2.55 2.34 2.16 2.01 1.89 1.78 1.69 1.62 1.54 1.48 1.43 1.38 1.33
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.8

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
1,000 mm – cover width
5.9

KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 100 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 42 50 56 58 60 61 61 61 61 61 60 59 59 59 59 59 59 59
I, II, III (f) 6.78 5.81 5.20 4.76 4.33 3.82 3.40 3.05 2.75 2.49 2.26 2.06 1.89 1.74 1.62 1.51 1.42 1.33 1.26 1.20
Span
40 40 40 40 40 40 40 40 40 42 43 44 46 47 47 50 51 52 53 54
I (f) 6.33 4.47 3.54 2.97 2.59 2.31 2.10 1.94 1.80 1.69 1.60 1.51 1.44 1.38 1.33 1.28 1.23 1.19 1.16 1.12
60 60 60 62 67 70 74 77 80 83 86 89 91 94 97 99 101 104 107 108
40 40 40 40 40 40 40 40 40 42 43 44 46 47 47 50 51 52 53 54
Double
II (f) 6.33 4.47 3.54 2.97 2.59 2.31 2.10 1.94 1.80 1.69 1.60 1.51 1.44 1.38 1.33 1.28 1.23 1.19 1.16 1.12
Span 60 60 60 62 67 70 74 77 80 83 86 89 91 94 97 99 101 104 107 108
40 40 40 40 40 40 40 40 40 42 43 44 46 47 47 50 51 52 53 54
III (f) 6.33 4.47 3.54 2.97 2.59 2.31 2.10 1.94 1.80 1.69 1.60 1.51 1.44 1.38 1.33 1.28 1.23 1.19 1.16 1.12
60 60 60 62 67 70 74 77 80 83 86 89 91 94 97 99 101 104 107 108
40 40 40 40 40 40 41 43 45 46 48 49 50 52 53 55 56 57 58 58
I (f) 7.22 5.07 3.99 3.34 2.90 2.58 2.34 2.15 2.00 1.87 1.76 1.67 1.59 1.52 1.46 1.41 1.36 1.32 1.26 1.20
60 60 65 70 74 78 82 86 89 92 95 98 101 104 106 109 112 115 116 116

Load-span tables
40 40 40 40 40 40 41 43 45 46 48 49 50 52 53 55 56 57 58 58
Multi Span II (f) 7.22 5.07 3.99 3.34 2.90 2.58 2.34 2.15 2.00 1.87 1.76 1.67 1.59 1.52 1.46 1.41 1.36 1.32 1.26 1.20
60 60 65 70 74 78 82 86 89 92 95 98 101 104 106 109 112 115 116 116
40 40 40 40 40 40 41 43 45 46 48 49 50 52 53 55 56 57 58 58
III (f) 7.22 5.07 3.99 3.34 2.90 2.58 2.34 2.15 2.00 1.87 1.76 1.67 1.59 1.52 1.46 1.41 1.36 1.32 1.26 1.20
60 60 65 70 74 78 82 86 89 92 95 98 101 104 106 109 112 115 116 116

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 100 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 6.78 5.75 5.18 4.80 4.47 4.16 3.86 3.61 3.40 3.23 3.08 2.95 2.83 2.73 2.64 2.55 2.43 2.32 2.21 2.11
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 10.46 7.64 5.74 4.52 3.78 3.27 2.91 2.63 2.41 2.23 2.08 1.95 1.84 1.75 1.67 1.59 1.53 1.47 1.41 1.36
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 10.46 7.64 5.45 4.28 3.58 3.11 2.76 2.50 2.30 2.13 1.99 1.87 1.77 1.68 1.61 1.54 1.48 1.42 1.37 1.32
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 10.46 7.22 5.01 3.93 3.29 2.86 2.56 2.32 2.14 1.99 1.86 1.76 1.67 1.59 1.52 1.46 1.40 1.35 1.30 1.26
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 10.78 7.64 6.06 5.18 4.33 3.73 3.29 2.96 2.69 2.48 2.30 2.15 2.03 1.92 1.82 1.74 1.66 1.60 1.54 1.48
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 10.78 7.64 6.06 5.05 4.19 3.60 3.18 2.86 2.60 2.40 2.23 2.08 1.96 1.86 1.77 1.69 1.62 1.55 1.49 1.44
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 10.78 7.64 6.06 4.79 3.97 3.41 3.01 2.70 2.46 2.27 2.12 1.98 1.87 1.77 1.69 1.61 1.54 1.49 1.43 1.38
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.10

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
1,000 mm – cover width
5.11

KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 120 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 47 59 70 79 83 86 87 88 88 88 86 85 84 83 82 80 80 79 78
I, II, III (f) 7.56 6.48 5.79 5.30 4.92 4.35 3.89 3.49 3.15 2.85 2.59 2.35 2.15 1.97 1.81 1.68 1.56 1.46 1.37 1.29
Span
40 40 40 40 43 45 48 50 52 53 55 57 58 60 62 63 65 67 68 69
I (f) 6.52 4.61 3.65 3.06 2.67 2.38 2.16 1.99 1.85 1.73 1.63 1.55 1.47 1.41 1.35 1.30 1.26 1.22 1.18 1.14
67 67 75 81 86 91 95 99 103 107 110 114 117 120 123 126 130 133 136 138
40 40 40 40 43 45 48 50 52 53 55 57 58 60 62 63 65 67 68 69
Double
II (f) 6.52 4.61 3.65 3.06 2.67 2.38 2.16 1.99 1.85 1.73 1.63 1.55 1.47 1.41 1.35 1.30 1.26 1.22 1.18 1.14
Span 67 67 75 81 86 91 95 99 103 107 110 114 117 120 123 126 130 133 136 138
40 40 40 40 43 45 48 50 52 53 55 57 58 60 62 63 65 67 68 69
III (f) 6.52 4.61 3.65 3.06 2.67 2.38 2.16 1.99 1.85 1.73 1.63 1.55 1.47 1.41 1.35 1.30 1.26 1.22 1.18 1.14
67 67 75 81 86 91 95 99 103 107 110 114 117 120 123 126 130 133 136 138
40 40 42 45 48 50 52 55 57 59 61 63 64 66 68 70 71 73 74 76
I (f) 7.41 5.20 4.09 3.42 2.96 2.63 2.38 2.19 2.03 1.90 1.79 1.70 1.62 1.55 1.48 1.43 1.38 1.33 1.29 1.26
64 76 84 90 95 100 105 109 113 117 121 125 129 132 135 139 142 145 148 152

Load-span tables
40 40 42 45 48 50 52 55 57 59 61 63 64 66 68 70 71 73 74 76
Multi Span II (f) 7.41 5.20 4.09 3.42 2.96 2.63 2.38 2.19 2.03 1.90 1.79 1.70 1.62 1.55 1.48 1.43 1.38 1.33 1.29 1.26
64 76 84 90 95 100 105 109 113 117 121 125 129 132 135 139 142 145 148 152
40 40 42 45 48 50 52 55 57 59 61 63 64 66 68 70 71 73 74 76
III (f) 7.41 5.20 4.09 3.42 2.96 2.63 2.38 2.19 2.03 1.90 1.79 1.70 1.62 1.55 1.48 1.43 1.38 1.33 1.29 1.26
64 76 84 90 95 100 105 109 113 117 121 125 129 132 135 139 142 145 148 152

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 RW 333.3 mm 333.3 mm 333.3 mm

30.5 mm 30.5 mm 30.5 mm 30.5 mm


58 mm
Roofpanel KS1000 RW 120 0.5 / 0.4 - S280/S280 – according to EN 14509 D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 7.75 6.70 5.98 5.49 5.01 4.55 4.20 3.93 3.70 3.50 3.34 3.20 3.07 2.96 2.86 2.77 2.69 2.61 2.55 2.45
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 10.79 8.36 6.17 4.82 4.01 3.46 3.07 2.77 2.54 2.34 2.18 2.05 1.93 1.83 1.74 1.66 1.59 1.53 1.47 1.32
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 10.79 8.37 5.86 4.57 3.80 3.29 2.92 2.64 2.42 2.24 2.09 1.96 1.86 1.76 1.68 1.60 1.54 1.48 1.42 1.32
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 10.79 7.86 5.37 4.18 3.48 3.03 2.70 2.45 2.25 2.09 1.96 1.85 1.75 1.66 1.59 1.52 1.46 1.41 1.36 1.32
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 11.98 8.36 6.62 5.55 4.58 3.93 3.45 3.09 2.81 2.58 2.40 2.24 2.10 1.99 1.88 1.80 1.72 1.65 1.58 1.52
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 11.98 8.36 6.62 5.37 4.43 3.79 3.33 2.98 2.71 2.50 2.32 216 2.04 1.89 1.83 1.74 1.67 1.60 1.54 1.48
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 11.89 8.36 6.59 5.09 4.19 3.58 3.15 2.82 2.57 2.36 2.20 2.06 1.94 1.84 1.74 1.67 1.60 1.54 1.48 1.43
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.12

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
1,000 mm – cover width
5.13

KS1000 FF 250 mm 250 mm 250 mm 250 mm

Roofpanel KS1000 FF 80 0.6 / 0.5 - S280/S280 – according to EN 14509


D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 42 60 67 74 78 82 85 87 90 90 91 91 91 91 91 91 91 91 43 92
I, II, III (f) 5.40 4.93 4.13 3.58 3.16 2.83 2.55 2.32 1.95 1.80 1.67 1.66 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
Span
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 91 91 91 91
I (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 181 182 182 182 182 182 182 182 182 182
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 91 91 91 91
Double
II (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
Span 99 120 135 147 157 164 170 174 177 179 181 182 182 182 182 182 182 182 182 182
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 91 91 91 91
III (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 181 182 182 182 182 182 182 182 182 182
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 91 91 91 91
I (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 181 182 182 182 182 182 182 182 182 182

Load-span tables
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 91 91 91 91
Multi Span II (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 181 182 182 182 182 182 182 182 182 182
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 91 91 91 91
III (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 181 182 182 182 182 182 182 182 182 182

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 FF 250 mm 250 mm 250 mm 250 mm

Roofpanel KS1000 FF 80 0.6 / 0.5 - S280/S280 – according to EN 14509


D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 5.40 5.40 5.01 4.61 3.94 3.27 2.82 2.48 2.23 2.03 1.87 1.74 1.63 1.54 1.46 1.39 1.32 1.27 1.22 1.18
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 6.31 6.31 4.48 3.40 2.80 2.42 2.14 1.94 1.79 1.66 1.55 1.46 1.39 1.32 1.26 1.21 1.17 1.13 1.09 1.05
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 6.31 6.31 4.01 3.05 2.52 2.19 1.96 1.78 1.65 1.54 1.45 1.37 1.30 1.25 1.20 1.15 1.11 1.07 1.04 1.01
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 6.31 4.20 2.25 1.92 1.74 1.62 1.52 1.44 1.38 1.32 1.28 1.24 1.19 1.14 1.10 1.06 1.03 1.00 0.97 0.95
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 8.27 8.27 5.45 4.11 3.35 2.85 2.50 2.24 2.04 1.88 1.75 1.64 1.55 1.47 1.40 1.34 1.29 1.24 1.20 1.16
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 8.27 8.17 5.13 3.85 3.13 2.67 2.34 2.10 1.92 1.77 1.65 1.55 1.47 1.40 1.33 1.28 1.23 1.18 1.14 1.11
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 8.24 7.44 4.61 3.44 2.80 2.39 2.10 1.90 1.74 1.61 1.51 1.42 1.35 1.29 1.24 1.19 1.14 1.10 1.07 1.04
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.14

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
1,000 mm – cover width
5.15

KS1000 FF 250 mm 250 mm 250 mm 250 mm

Roofpanel KS1000 FF 100 0.6 / 0.5 - S280/S280 – according to EN 14509


D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 42 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 91 91 91 91
I, II, III (f) 5.40 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
Span
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 51 91 91 91
I (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 179 182 182 182 182 182 101 182 182 182
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 51 91 91 91
Double
II (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
Span 99 120 135 147 157 164 170 174 177 179 179 182 182 182 182 182 101 182 182 182
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 51 91 91 91
III (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 179 182 182 182 182 182 101 182 182 182
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 51 91 91 91
I (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 179 182 182 182 182 182 101 182 182 182

Load-span tables
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 51 91 91 91
Multi Span II (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 179 182 182 182 182 182 101 182 182 182
49 60 67 74 78 82 85 87 88 90 90 91 91 91 91 91 51 91 91 91
III (f) 6.28 4.93 4.13 3.58 3.16 2.83 2.55 2.32 2.12 1.95 1.80 1.67 1.55 1.45 1.36 1.28 1.20 1.14 1.08 1.04
99 120 135 147 157 164 170 174 177 179 179 182 182 182 182 182 101 182 182 182

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 FF 250 mm 250 mm 250 mm 250 mm

Roofpanel KS1000 FF 100 0.6 / 0.5 - S280/S280 – according to EN 14509


D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 6.15 6.15 5.85 4.19 3.30 2.75 2.37 2.10 1.89 1.73 1.60 1.49 1.40 1.32 1.26 1.20 1.15 1.11 1.07 1.03
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 4.28 4.28 4.28 3.64 2.98 2.56 2.26 2.04 1.88 1.73 1.60 1.49 1.40 1.32 1.26 1.20 1.15 1.11 1.07 1.03
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 4.28 4.28 4.28 3.26 2.69 2.33 2.08 1.89 1.74 1.62 1.52 1.44 1.37 1.30 1.25 1.20 1.15 1.11 1.07 1.03
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 4.28 4.28 2.59 2.20 1.98 1.82 1.71 1.62 1.54 1.47 1.39 1.32 1.26 1.21 1.16 1.12 1.08 1.05 1.02 0.99
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.44 5.44 5.44 4.19 3.30 2.75 2.37 2.10 1.89 1.73 1.60 1.49 1.40 1.32 1.26 1.20 1.15 1.11 1.07 1.03
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 5.44 5.44 5.44 4.09 3.28 2.75 2.37 2.10 1.89 1.73 1.60 1.49 1.40 1.32 1.26 1.20 1.15 1.11 1.07 1.03
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.44 5.44 4.99 3.64 2.92 2.48 2.18 1.96 1.80 1.67 1.56 1.47 1.40 1.32 1.26 1.20 1.15 1.11 1.07 1.03
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.16

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
1,000 mm – cover width
5.17

KS1000 FF 250 mm 250 mm 250 mm 250 mm

Roofpanel KS1000 FF 120 0.6 / 0.5 - S280/S280 – according to EN 14509


D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 59 71 73 75 76 78 79 81 82 84 86 87 89 90 92 94 95 97 98 100
I, II, III (f) 6.84 5.53 4.26 3.49 2.98 2.61 2.33 2.11 1.94 1.80 1.68 1.58 1.50 1.42 1.36 1.30 1.25 1.20 1.16 1.12
Span
41 61 73 74 76 78 79 81 82 84 86 87 89 90 92 94 95 97 98 100
I (f) 4.70 4.70 4.25 3.48 2.97 2.60 2.33 2.11 1.94 1.80 1.68 1.58 1.49 1.42 1.36 1.30 1.25 1.20 1.16 1.12
81 122 146 149 152 155 159 162 165 168 171 174 177 181 185 188 191 193 197 200
41 61 73 74 76 78 79 81 82 84 86 87 89 90 92 94 95 97 98 100
Double
II (f) 4.70 4.70 4.25 3.48 2.97 2.60 2.33 2.11 1.94 1.80 1.68 1.58 1.49 1.42 1.36 1.30 1.25 1.20 1.16 1.12
Span 81 122 146 149 152 155 159 162 165 168 171 174 177 181 185 188 191 193 197 200
41 61 73 74 76 78 79 81 82 84 86 87 89 90 92 94 95 97 98 100
III (f) 4.70 4.70 4.25 3.48 2.97 2.60 2.33 2.11 1.94 1.80 1.68 1.58 1.49 1.42 1.36 1.30 1.25 1.20 1.16 1.12
81 122 146 149 152 155 159 162 165 168 171 174 177 181 185 188 191 193 197 200
50 71 73 74 76 78 79 81 82 84 86 87 89 90 92 94 95 97 98 100
I (f) 5.74 5.52 4.25 3.48 2.97 2.60 2.33 2.11 1.94 1.80 1.68 1.58 1.49 1.42 1.36 1.30 1.25 1.20 1.16 1.12
100 142 146 149 152 155 159 162 165 168 171 174 177 181 185 188 191 193 197 200

Load-span tables
50 71 73 74 76 78 79 81 82 84 86 87 89 90 92 94 95 97 98 100
Multi Span II (f) 5.74 5.52 4.25 3.48 2.97 2.60 2.33 2.11 1.94 1.80 1.68 1.58 1.49 1.42 1.36 1.30 1.25 1.20 1.16 1.12
100 142 146 149 152 155 159 162 165 168 171 174 177 181 185 188 191 193 197 200
50 71 73 74 76 78 79 81 82 84 86 87 89 90 92 94 95 97 98 100
III (f) 5.74 5.52 4.25 3.48 2.97 2.60 2.33 2.11 1.94 1.80 1.68 1.58 1.49 1.42 1.36 1.30 1.25 1.20 1.16 1.12
100 142 146 149 152 155 159 162 165 168 171 174 177 181 185 188 191 193 197 200

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 FF 250 mm 250 mm 250 mm 250 mm

Roofpanel KS1000 FF 120 0.6 / 0.5 - S280/S280 – according to EN 14509


D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 6.84 6.84 6.53 4.62 3.62 3.00 2.58 2.27 2.04 1.86 1.72 1.60 1.50 1.41 1.34 1.28 1.22 1.17 1.13 1.09
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 4.69 4.69 4.69 3.93 3.18 2.72 2.40 2.16 1.98 1.83 1.70 1.60 1.50 1.41 1.34 1.28 1.22 1.17 1.13 1.09
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 4.69 4.69 4.69 3.52 2.88 2.48 2.20 2.00 1.84 1.71 1.60 1.51 1.43 1.36 1.30 1.25 1.20 1.16 1.12 1.08
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 4.69 4.69 2.95 2.45 2.19 2.00 1.87 1.76 1.66 1.56 1.47 1.39 1.33 1.27 1.22 1.17 1.13 1.09 1.06 1.03
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.73 5.73 5.73 4.63 3.62 3.00 2.58 2.27 2.04 1.86 1.72 1.60 1.50 1.41 1.34 1.28 1.22 1.17 1.13 1.09
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 5.73 5.73 5.73 4.38 3.48 2.92 2.54 2.27 2.04 1.86 1.72 1.60 1.50 1.41 1.34 1.28 1.22 1.17 1.13 1.09
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.73 5.73 5.73 3.88 3.08 2.60 2.28 2.05 1.88 1.74 1.62 1.53 1.45 1.38 1.32 1.27 1.22 1.17 1.13 1.09
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.18

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
1,000 mm – cover width
5.19

KS1000 FF 250 mm 250 mm 250 mm 250 mm

Roofpanel KS1000 FF 150 0.6 / 0.5 - S280/S280 – according to EN 14509


D
d

Colour characteristic downwards load, e.g. snow load [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 63 72 74 76 77 79 81 82 84 85 87 89 90 92 94 95 97 99 100 102
I, II, III (f) 8.83 6.38 4.75 3.82 3.21 2.79 2.48 2.23 2.04 1.89 1.76 1.65 1.56 1.48 1.41 1.34 1.29 1.24 1.20 1.16
Span
42 68 74 75 77 79 80 82 84 85 87 89 90 92 94 95 97 99 100 102
I (f) 5.97 5.97 4.74 3.81 3.21 2.78 2.47 2.23 2.04 1.88 1.76 1.65 1.56 1.48 1.41 1.34 1.29 1.24 1.20 1.14
85 135 148 151 154 157 161 164 168 170 174 177 180 184 188 190 194 198 200 204
42 68 74 75 77 79 80 82 84 85 87 89 90 92 94 95 97 99 100 102
Double
II (f) 5.97 5.97 4.74 3.81 3.21 2.78 2.47 2.23 2.04 1.88 1.76 1.65 1.56 1.48 1.41 1.34 1.29 1.24 1.20 1.14
Span 85 135 148 150 154 157 161 164 168 170 174 177 180 184 188 190 194 198 200 204
42 68 74 75 77 79 80 82 84 85 87 89 90 92 94 95 97 99 100 102
III (f) 5.97 5.97 4.74 3.81 3.21 2.78 2.47 2.23 2.04 1.88 1.76 1.65 1.56 1.48 1.41 1.34 1.29 1.24 1.20 1.14
85 135 148 150 154 157 161 164 168 170 174 177 180 184 188 190 194 198 200 204
53 72 74 76 77 79 80 82 84 85 87 89 90 92 94 95 97 99 100 102
I (f) 7.52 6.36 4.74 3.81 3.21 2.78 2.47 2.23 2.04 1.88 1.76 1.65 1.56 1.48 1.41 1.34 1.29 1.24 1.20 1.14
107 144 148 152 154 157 161 164 168 170 174 177 180 184 188 190 194 198 200 204

Load-span tables
53 72 74 76 77 79 80 82 84 85 87 89 90 92 94 95 97 99 100 102
Multi Span II (f) 7.52 6.36 4.74 3.81 3.21 2.78 2.47 2.23 2.04 1.88 1.76 1.65 1.56 1.48 1.41 1.34 1.29 1.24 1.20 1.14
107 144 148 152 154 157 161 164 168 170 174 177 180 184 188 190 194 198 200 204
53 72 74 76 77 79 80 82 84 85 87 89 90 92 94 95 97 99 100 102
III (f) 7.52 3.63 4.74 3.81 3.21 2.78 2.47 2.23 2.04 1.88 1.76 1.65 1.56 1.48 1.41 1.34 1.29 1.24 1.20 1.14
107 144 148 152 154 157 161 164 168 170 174 177 180 184 188 190 194 198 200 204

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
1,000 mm – cover width

Load-span tables
KS1000 FF 250 mm 250 mm 250 mm 250 mm

Roofpanel KS1000 FF 150 0.6 / 0.5 - S280/S280 – according to EN 14509


D
d

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 8.82 8.82 6.19 4.53 3.61 3.02 2.61 2.32 2.09 1.91 1.76 1.64 1.54 1.46 1.38 1.32 1.26 1.21 1.16 1.12
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.97 5.97 4.86 3.74 3.11 2.70 2.40 2.17 1.99 1.85 1.72 1.62 1.53 1.45 1.38 1.32 1.26 1.21 1.16 1.12
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 5.97 5.97 4.34 3.38 2.84 2.49 2.23 2.03 1.88 1.74 1.64 1.54 1.46 1.39 1.33 1.28 1.22 1.18 1.14 1.10
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.97 3.72 2.93 2.56 2.32 2.14 2.01 1.85 1.72 1.61 1.52 1.44 1.37 1.31 1.26 1.21 1.16 1.12 1.09 1.05
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 7.51 7.51 5.83 4.36 3.54 3.01 2.61 2.32 2.09 1.91 1.76 1.64 1.54 1.46 1.38 1.32 1.26 1.21 1.16 1.12
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 7.51 7.51 5.42 4.06 3.30 2.82 2.48 2.23 2.04 1.89 1.76 1.64 1.54 1.46 1.38 1.32 1.26 1.21 1.16 1.12
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 7.51 7.51 4.78 3.58 2.94 2.53 2.25 2.04 1.88 1.75 1.64 1.55 1.47 1.40 1.34 1.29 1.24 1.20 1.16 1.12
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.20

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.21

KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 40 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 4.66 4.04 3.56 3.22 2.98 2.78 2.62 2.43 2.16 1.95 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.10 3.82 3.27 2.94 2.71 2.54 2.40 2.28 2.16 1.94 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.99
60 60 60 60 60 60 66 72 77 76 77 77 77 77 77 77 77 77 77 77
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 5.10 3.82 3.27 2.94 2.71 2.54 2.40 2.28 2.16 1.94 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.99
Span 60 60 60 60 60 60 66 72 77 76 77 77 77 77 77 77 77 77 77 77
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.10 3.82 3.27 2.94 2.71 2.54 2.40 2.28 2.16 1.94 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.99
60 60 60 60 60 60 66 72 77 76 77 77 77 77 77 77 77 77 77 77
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 6.51 4.65 3.82 3.34 3.01 2.77 2.58 2.43 2.16 1.94 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
60 60 60 60 60 65 71 77 77 76 77 77 77 77 77 77 77 77 77 77

Load-span tables
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 6.51 4.65 3.82 3.34 3.01 2.77 2.58 2.43 2.16 1.94 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
60 60 60 60 60 65 71 77 77 76 77 77 77 77 77 77 77 77 77 77
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 6.51 4.65 3.82 3.34 3.01 2.77 2.58 2.43 2.16 1.94 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
60 60 60 60 60 65 71 77 77 76 77 77 77 77 77 77 77 77 77 77

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 40 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 3.88 3.48 3.21 2.96 2.65 2.42 2.24 2.09 1.97 1.87 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.92 4.19 3.42 2.96 2.65 2.42 2.24 2.09 1.97 1.87 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 5.92 4.19 3.42 2.96 2.65 2.42 2.24 2.09 1.97 1.87 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.92 4.19 3.42 2.96 2.65 2.42 2.24 2.09 1.97 1.87 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.92 4.19 3.42 2.96 2.65 2.42 2.24 2.09 1.97 1.87 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 5.92 4.19 3.42 2.96 2.65 2.42 2.24 2.09 1.97 1.87 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.92 4.19 3.42 2.96 2.65 2.42 2.24 2.09 1.97 1.87 1.77 1.62 1.50 1.39 1.30 1.22 1.14 1.08 1.02 0.98
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.22

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.23

KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 60 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 45 49 53 56 58 58 58 58 58 58 58 58 58 58 58
I, II, III (f) 6.61 5.53 4.85 4.40 4.07 3.77 3.53 3.34 3.17 2.96 2.69 2.46 2.28 2.11 1.97 1.85 1.74 1.64 1.56 1.48
Span
40 40 40 40 40 40 41 44 47 51 54 57 58 58 58 58 58 58 58 58
I (f) 6.28 4.71 4.03 3.62 3.34 3.13 2.95 2.80 2.68 2.58 2.49 2.41 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 60 66 74 81 88 95 102 108 114 116 116 116 116 116 116 116 116
40 40 40 40 40 40 41 44 47 51 54 57 58 58 58 58 58 58 58 58
Double
II (f) 6.28 4.71 4.03 3.62 3.34 3.13 2.95 2.80 2.68 2.58 2.49 2.41 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
Span 60 60 60 60 66 74 81 88 95 102 108 114 116 116 116 116 116 116 116 116
40 40 40 40 40 40 41 44 47 51 54 57 58 58 58 58 58 58 58 58
III (f) 6.28 4.71 4.03 3.62 3.34 3.13 2.95 2.80 2.68 2.58 2.49 2.41 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 60 66 74 81 88 95 102 108 114 116 116 116 116 116 116 116 116
40 40 40 40 40 40 44 47 50 53 56 58 58 58 58 58 58 58 58 58
I (f) 8.02 5.72 4.71 4.12 3.71 3.41 3.18 2.99 2.84 2.71 2.60 2.46 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 65 73 81 88 94 101 107 113 116 116 116 116 116 116 116 116 116

Load-span tables
40 40 40 40 40 40 44 47 50 53 56 58 58 58 58 58 58 58 58 58
Multi Span II (f) 8.02 5.72 4.71 4.12 3.71 3.41 3.18 2.99 2.84 2.71 2.60 2.46 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 65 73 81 88 94 101 107 113 116 116 116 116 116 116 116 116 116
40 40 40 40 40 40 44 47 50 53 56 58 58 58 58 58 58 58 58 58
III (f) 8.02 5.72 4.71 4.12 3.71 3.41 3.18 2.99 2.84 2.71 2.60 2.46 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 65 73 81 88 94 101 107 113 116 116 116 116 116 116 116 116 116

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 60 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 5.62 4.97 4.21 3.65 3.26 2.98 2.76 2.58 2.43 2.31 2.20 2.11 2.02 1.95 1.88 1.82 1.74 1.64 1.56 1.48
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 7.30 5.16 4.21 3.65 3.26 2.98 2.76 2.58 2.43 2.31 2.20 2.11 2.02 1.95 1.88 1.82 1.74 1.64 1.56 1.48
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 7.30 5.16 4.21 3.65 3.26 2.98 2.76 2.58 2.43 2.31 2.20 2.11 2.02 1.95 1.88 1.82 1.74 1.64 1.56 1.48
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 7.30 5.16 4.21 3.65 3.26 2.98 2.76 2.58 2.43 2.31 2.20 2.11 2.02 1.95 1.88 1.82 1.74 1.64 1.56 1.48
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 7.30 5.16 4.21 3.65 3.26 2.98 2.76 2.58 2.43 2.31 2.20 2.11 2.02 1.95 1.88 1.82 1.74 1.64 1.56 1.48
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 7.30 5.16 4.21 3.65 3.26 2.98 2.76 2.58 2.43 2.31 2.20 2.11 2.02 1.95 1.88 1.82 1.74 1.64 1.56 1.48
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 7.30 5.16 4.21 3.65 3.26 2.98 2.76 2.58 2.43 2.31 2.20 2.11 2.02 1.95 1.88 1.82 1.74 1.64 1.56 1.48
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.24

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.25

KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 80 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 43 49 54 59 63 67 70 74 77 78 78 78 78 78 78 78 78
I, II, III (f) 8.39 6.86 6.01 5.46 5.00 4.61 4.27 3.99 3.76 3.57 3.40 3.26 3.05 2.84 2.64 2.48 2.33 2.20 2.09 1.98
Span
40 40 40 40 40 43 47 51 55 59 62 66 69 73 76 78 78 78 78 78
I (f) 7.27 5.46 4.66 4.19 3.87 3.63 3.42 3.25 3.10 2.98 2.88 2.79 2.71 2.64 2.58 2.48 2.33 2.20 2.09 1.98
60 60 60 66 76 86 94 102 110 117 125 132 139 146 152 156 156 156 156 156
40 40 40 40 40 43 47 51 55 59 62 66 69 73 76 78 78 78 78 78
Double
II (f) 7.27 5.46 4.66 4.19 3.87 3.63 3.42 3.25 3.10 2.98 2.88 2.79 2.71 2.64 2.58 2.48 2.33 2.20 2.09 1.98
Span 60 60 60 66 76 86 94 102 110 117 125 132 139 146 152 156 156 156 156 156
40 40 40 40 40 43 47 51 55 59 62 66 69 73 76 78 78 78 78 78
III (f) 7.27 5.46 4.66 4.19 3.87 3.63 3.42 3.25 3.10 2.98 2.88 2.79 2.71 2.64 2.58 2.48 2.33 2.20 2.09 1.98
60 60 60 66 76 86 94 102 110 117 125 132 139 146 152 156 156 156 156 156
40 40 40 40 42 47 51 55 58 62 65 69 72 75 78 78 78 78 78 78
I (f) 9.29 6.63 5.46 4.77 4.30 3.95 3.68 3.47 3.29 3.14 3.01 2.90 2.80 2.72 2.64 2.48 2.33 2.20 2.09 1.98
60 60 64 75 85 93 102 110 117 124 130 137 144 150 156 156 156 156 156 156

Load-span tables
40 40 40 40 42 47 51 55 58 62 65 69 72 75 78 78 78 78 78 78
Multi Span II (f) 9.29 6.63 5.46 4.77 4.30 3.95 3.68 3.47 3.29 3.14 3.01 2.90 2.80 2.72 2.64 2.48 2.33 2.20 2.09 1.98
60 60 64 75 85 93 102 110 117 124 130 137 144 150 156 156 156 156 156 156
40 40 40 40 42 47 51 55 58 62 65 69 72 75 78 78 78 78 78 78
III (f) 9.29 6.63 5.46 4.77 4.30 3.95 3.68 3.47 3.29 3.14 3.01 2.90 2.80 2.72 2.64 2.48 2.33 2.20 2.09 1.98
60 60 64 75 85 93 102 110 117 124 130 137 144 150 156 156 156 156 156 156

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 80 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 7.24 5.98 4.88 4.23 3.78 3.45 3.20 2.99 2.82 2.67 2.55 2.44 2.34 2.26 2.18 2.11 2.05 1.99 1.94 1.89
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 8.45 5.98 4.88 4.23 3.78 3.45 3.20 2.99 2.82 2.67 2.55 2.44 2.34 2.26 2.18 2.11 2.05 1.99 1.94 1.89
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 8.45 5.98 4.88 4.23 3.78 3.45 3.20 2.99 2.82 2.67 2.55 2.44 2.34 2.26 2.18 2.11 2.05 1.99 1.94 1.89
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 8.45 5.98 4.88 4.23 3.78 3.45 3.20 2.99 2.82 2.67 2.55 2.44 2.34 2.26 2.18 2.11 2.05 1.99 1.94 1.89
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 8.45 5.98 4.88 4.23 3.78 3.45 3.20 2.99 2.82 2.67 2.55 2.44 2.34 2.26 2.18 2.11 2.05 1.99 1.94 1.89
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 8.45 5.98 4.88 4.23 3.78 3.45 3.20 2.99 2.82 2.67 2.55 2.44 2.34 2.26 2.18 2.11 2.05 1.99 1.94 1.89
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 8.45 5.98 4.88 4.23 3.78 3.45 3.20 2.99 2.82 2.67 2.55 2.44 2.34 2.26 2.18 2.11 2.05 1.99 1.94 1.89
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.26

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.27

KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 100 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 50 60 67 73 79 84 90 94 99 103 108 108 108 108 108 108 109 109
I, II, III (f) 9.99 8.05 7.05 6.32 5.65 5.16 4.78 4.47 4.21 4.00 3.81 3.65 3.51 3.28 3.06 2.87 2.70 2.55 2.42 2.30
Span
40 40 40 45 52 58 64 70 75 80 85 90 95 99 104 108 108 108 109 109
I (f) 8.20 6.17 5.28 4.76 4.39 4.11 3.87 3.68 3.52 3.38 3.27 3.17 3.08 3.00 2.93 2.86 2.70 2.55 2.42 2.30
60 60 75 90 104 117 128 139 150 160 170 180 190 198 208 216 217 217 217 217
40 40 40 45 52 58 64 70 75 80 85 90 95 99 104 108 108 108 109 109
Double
II (f) 8.20 6.17 5.28 4.76 4.39 4.11 3.87 3.68 3.52 3.38 3.27 3.17 3.08 3.00 2.93 2.86 2.70 2.55 2.42 2.30
Span 60 60 75 90 104 117 128 139 150 160 170 180 190 198 208 216 217 217 217 217
40 40 40 45 52 58 64 70 75 80 85 90 95 99 104 108 108 108 109 109
III (f) 8.20 6.17 5.28 4.76 4.39 4.11 3.87 3.68 3.52 3.38 3.27 3.17 3.08 3.00 2.93 2.86 2.70 2.55 2.42 2.30
60 60 75 90 104 117 128 139 150 160 170 180 190 198 208 216 217 217 217 217
40 40 43 51 57 63 68 74 79 84 88 93 97 102 106 108 108 108 109 109
I (f) 10.42 7.44 6.13 5.35 4.83 4.44 4.14 3.90 3.71 3.54 3.40 3.27 3.16 3.07 2.98 2.87 2.70 2.55 2.42 2.30
60 70 87 101 114 126 137 147 158 167 177 185 194 203 212 217 217 217 217 217

Load-span tables
40 40 43 51 57 63 68 74 79 84 88 93 97 102 106 108 108 108 109 109
Multi Span II (f) 10.42 7.44 6.13 5.35 4.83 4.44 4.14 3.90 3.71 3.54 3.40 3.27 3.16 3.07 2.98 2.87 2.70 2.55 2.42 2.30
60 70 87 101 114 126 137 147 158 167 177 185 194 203 212 217 217 217 217 217
40 40 43 51 57 63 68 74 79 84 88 93 97 102 106 108 108 108 109 109
III (f) 10.42 7.44 6.13 5.35 4.83 4.44 4.14 3.90 3.71 3.54 3.40 3.27 3.16 3.07 2.98 2.87 2.70 2.55 2.42 2.30
60 70 87 101 114 126 137 147 158 167 177 185 194 203 212 217 217 217 217 217

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 100 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 8.76 6.70 5.47 4.73 4.23 3.86 3.58 3.35 3.16 2.99 2.86 2.73 2.63 2.53 2.44 2.37 2.30 2.23 2.17 2.12
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 9.47 6.70 5.47 4.73 4.23 3.86 3.58 3.35 3.16 2.99 2.86 2.73 2.63 2.53 2.44 2.37 2.30 2.23 2.17 2.12
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 9.47 6.70 5.47 4.73 4.23 3.86 3.58 3.35 3.16 2.99 2.86 2.73 2.63 2.53 2.44 2.37 2.30 2.23 2.17 2.12
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 9.47 6.70 5.47 4.73 4.23 3.86 3.58 3.35 3.16 2.99 2.86 2.73 2.63 2.53 2.44 2.37 2.30 2.23 2.17 2.12
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 9.47 6.70 5.47 4.73 4.23 3.86 3.58 3.35 3.16 2.99 2.86 2.73 2.63 2.53 2.44 2.37 2.30 2.23 2.17 2.12
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 9.47 6.70 5.47 4.73 4.23 3.86 3.58 3.35 3.16 2.99 2.86 2.73 2.63 2.53 2.44 2.37 2.30 2.23 2.17 2.12
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 9.47 6.70 5.47 4.73 4.23 3.86 3.58 3.35 3.16 2.99 2.86 2.73 2.63 2.53 2.44 2.37 2.30 2.23 2.17 2.12
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.28

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.29

KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 120 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 54 71 82 92 100 108 116 123 129 136 142 148 150 150 150 150 150 150 150
I, II, III (f) 11.38 9.17 7.99 6.93 6.20 5.66 5.24 4.90 4.62 4.38 4.18 4.00 3.85 3.62 3.38 3.17 2.98 2.82 2.67 2.53
Span
40 40 52 62 71 81 89 96 104 111 118 125 131 138 144 150 150 150 150 150
I (f) 9.06 6.85 5.87 5.29 4.89 4.56 4.29 4.08 3.91 3.76 3.64 3.52 3.42 3.34 3.26 3.17 2.98 2.82 2.67 2.53
60 81 104 125 144 162 177 193 208 222 236 249 263 276 289 300 300 300 300 300
40 40 52 62 71 81 89 96 104 111 118 125 131 138 144 150 150 150 150 150
Double
II (f) 9.06 6.85 5.87 5.29 4.89 4.56 4.29 4.08 3.91 3.76 3.64 3.52 3.42 3.34 3.26 3.17 2.98 2.82 2.67 2.53
Span 60 81 104 125 144 162 177 193 208 222 236 249 263 276 289 300 300 300 300 300
40 40 52 62 71 81 89 96 104 111 118 125 131 138 144 150 150 150 150 150
III (f) 9.06 6.85 5.87 5.29 4.89 4.56 4.29 4.08 3.91 3.76 3.64 3.52 3.42 3.34 3.26 3.17 2.98 2.82 2.67 2.53
60 81 104 125 144 162 177 193 208 222 236 249 263 276 289 300 300 300 300 300
40 48 60 70 79 87 94 102 109 115 122 128 134 140 146 150 150 150 150 150
I (f) 11.44 8.17 6.74 5.89 5.32 4.90 4.57 4.31 4.09 3.91 3.75 3.62 3.50 3.39 3.30 3.17 2.98 2.82 2.67 2.53
68 97 120 139 157 174 189 204 217 231 244 257 269 280 292 300 300 300 300 300

Load-span tables
40 48 60 70 79 87 94 102 109 115 122 128 134 140 146 150 150 150 150 150
Multi Span II (f) 11.44 8.17 6.74 5.89 5.32 4.90 4.57 4.31 4.09 3.91 3.75 3.62 3.50 3.39 3.30 3.17 2.98 2.82 2.67 2.53
68 97 120 139 157 174 189 204 217 231 244 257 269 280 292 300 300 300 300 300
40 48 60 70 79 87 94 102 109 115 122 128 134 140 146 150 150 150 150 150
III (f) 11.44 8.17 6.74 5.89 5.32 4.90 4.57 4.31 4.09 3.91 3.75 3.62 3.50 3.39 3.30 3.17 2.98 2.82 2.67 2.53
68 97 120 139 157 174 189 204 217 231 244 257 269 280 292 300 300 300 300 300

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 120 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 10.20 7.34 6.00 5.19 4.64 4.24 3.92 3.67 3.46 3.28 3.13 3.00 2.88 2.78 2.68 2.60 2.52 2.45 2.38 2.32
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 10.38 7.34 6.00 5.19 4.64 4.24 3.92 3.67 3.46 3.28 3.13 3.00 2.88 2.78 2.68 2.60 2.52 2.45 2.38 2.32
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 10.38 7.34 6.00 5.19 4.64 4.24 3.92 3.67 3.46 3.28 3.13 3.00 2.88 2.78 2.68 2.60 2.52 2.45 2.38 2.32
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 10.38 7.34 6.00 5.19 4.64 4.24 3.92 3.67 3.46 3.28 3.13 3.00 2.88 2.78 2.68 2.60 2.52 2.45 2.38 2.32
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 10.38 7.34 6.00 5.19 4.64 4.24 3.92 3.67 3.46 3.28 3.13 3.00 2.88 2.78 2.68 2.60 2.52 2.45 2.38 2.32
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 10.38 7.34 6.00 5.19 4.64 4.24 3.92 3.67 3.46 3.28 3.13 3.00 2.88 2.78 2.68 2.60 2.52 2.45 2.38 2.32
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 10.38 7.34 6.00 5.19 4.64 4.24 3.92 3.67 3.46 3.28 3.13 3.00 2.88 2.78 2.68 2.60 2.52 2.45 2.38 2.32
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.30

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.31

KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 150 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 56 68 79 88 97 104 112 118 125 131 137 142 148 153 158 162 165 165 165
I, II, III (f) 13.40 10.74 8.77 7.60 6.79 6.20 5.74 5.37 5.06 4.80 4.58 4.39 4.21 4.06 3.92 3.80 3.68 3.53 3.34 3.18
Span
40 40 51 62 71 80 88 95 103 110 117 123 130 136 143 149 155 161 165 165
I (f) 10.16 7.68 6.59 5.94 5.49 5.11 4.82 4.58 4.39 4.22 4.08 3.96 3.85 3.75 3.66 3.58 3.51 3.44 3.34 3.18
60 80 103 123 143 159 175 190 205 219 233 247 260 273 285 297 310 322 330 330
40 40 51 62 71 80 88 95 103 110 117 123 130 136 143 149 155 161 165 165
Double
II (f) 10.16 7.68 6.59 5.94 5.49 5.11 4.82 4.58 4.39 4.22 4.08 3.96 3.85 3.75 3.66 3.58 3.51 3.44 3.34 3.18
Span 60 80 103 123 143 159 175 190 205 219 233 247 260 273 285 297 310 322 330 330
40 40 51 62 71 80 88 95 103 110 117 123 130 136 143 149 155 161 165 165
III (f) 10.16 7.68 6.59 5.94 5.49 5.11 4.82 4.58 4.39 4.22 4.08 3.96 3.85 3.75 3.66 3.58 3.51 3.44 3.34 3.18
60 80 103 123 143 159 175 190 205 219 233 247 260 273 285 297 310 322 330 330
40 48 59 69 77 86 93 100 107 114 120 126 132 138 144 150 155 160 165 165
I (f) 12.81 9.15 7.55 6.60 5.96 5.49 5.12 4.83 4.59 4.38 4.21 4.06 3.92 3.80 3.70 3.60 3.51 3.43 3.34 3.18
67 95 118 137 155 171 186 201 214 227 240 253 265 276 288 300 310 321 330 330

Load-span tables
40 48 59 69 77 86 93 100 107 114 120 126 132 138 144 150 155 160 165 165
Multi Span II (f) 12.81 9.15 7.55 6.60 5.96 5.49 5.12 4.83 4.59 4.38 4.21 4.06 3.92 3.80 3.70 3.60 3.51 3.43 3.34 3.18
67 95 118 137 155 171 186 201 214 227 240 253 265 276 288 300 310 321 330 330
40 48 59 69 77 86 93 100 107 114 120 126 132 138 144 150 155 160 165 165
III (f) 12.81 9.15 7.55 6.60 5.96 5.49 5.12 4.83 4.59 4.38 4.21 4.06 3.92 3.80 3.70 3.60 3.51 3.43 3.34 3.18
67 95 118 137 155 171 186 201 214 227 240 253 265 276 288 300 310 321 330 330

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 150 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 11.83 8.36 6.83 5.91 5.29 4.83 4.47 4.18 3.94 3.74 3.57 3.41 3.28 3.16 3.05 2.96 2.87 2.79 2.71 2.64
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 11.83 8.36 6.83 5.91 5.29 4.83 4.47 4.18 3.94 3.74 3.57 3.41 3.28 3.16 3.05 2.96 2.87 2.79 2.71 2.64
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 11.83 8.36 6.83 5.91 5.29 4.83 4.47 4.18 3.94 3.74 3.57 3.41 3.28 3.16 3.05 2.96 2.87 2.79 2.71 2.64
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 11.83 8.36 6.83 5.91 5.29 4.83 4.47 4.18 3.94 3.74 3.57 3.41 3.28 3.16 3.05 2.96 2.87 2.79 2.71 2.64
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 11.83 8.36 6.83 5.91 5.29 4.83 4.47 4.18 3.94 3.74 3.57 3.41 3.28 3.16 3.05 2.96 2.87 2.79 2.71 2.64
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 11.83 8.36 6.83 5.91 5.29 4.83 4.47 4.18 3.94 3.74 3.57 3.41 3.28 3.16 3.05 2.96 2.87 2.79 2.71 2.64
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 11.83 8.36 6.83 5.91 5.29 4.83 4.47 4.18 3.94 3.74 3.57 3.41 3.28 3.16 3.05 2.96 2.87 2.79 2.71 2.64
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.32

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.33

KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 170 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 54 66 76 85 93 101 108 114 120 126 132 137 142 147 152 157 162 166 170
I, II, III (f) 14.68 11.27 9.21 7.97 7.13 6.51 6.03 5.64 5.32 5.04 4.81 4.60 4.42 4.26 4.12 3.99 3.87 3.76 3.66 3.56
Span
40 40 50 61 70 78 86 93 101 108 114 121 128 134 140 146 152 158 164 169
I (f) 10.83 8.19 7.03 6.34 5.86 5.45 5.14 4.89 4.68 4.51 4.36 4.22 4.11 4.00 3.91 3.82 3.75 3.68 3.61 3.55
60 78 101 121 140 156 172 187 202 215 229 242 256 268 280 292 304 316 327 339
40 40 50 61 70 78 86 93 101 108 114 121 128 134 140 146 152 158 164 169
Double
II (f) 10.83 8.19 7.03 6.34 5.86 5.45 5.14 4.89 4.68 4.51 4.36 4.22 4.11 4.00 3.91 3.82 3.75 3.68 3.61 3.55
Span 60 78 101 121 140 156 172 187 202 215 229 242 256 268 280 292 304 316 327 339
40 40 50 61 70 78 86 93 101 108 114 121 128 134 140 146 152 158 164 169
III (f) 10.83 8.19 7.03 6.34 5.86 5.45 5.14 4.89 4.68 4.51 4.36 4.22 4.11 4.00 3.91 3.82 3.75 3.68 3.61 3.55
60 78 101 121 140 156 172 187 202 215 229 242 256 268 280 292 304 316 327 339
40 47 58 67 76 84 91 98 105 111 118 124 130 136 141 147 152 157 162 168
I (f) 13.65 9.75 8.04 7.03 6.35 5.85 5.46 5.15 4.89 4.67 4.49 4.32 4.18 4.06 3.94 3.84 3.75 3.66 3.58 3.51
65 93 115 134 152 168 182 197 210 223 236 247 259 272 282 293 304 314 325 335

Load-span tables
40 47 58 67 76 84 91 98 105 111 118 124 130 136 141 147 152 157 162 168
Multi Span II (f) 13.65 9.75 8.04 7.03 6.35 5.85 5.46 5.15 4.89 4.67 4.49 4.32 4.18 4.06 3.94 3.84 3.75 3.66 3.58 3.51
65 93 115 134 152 168 182 197 210 223 236 247 259 272 282 293 304 314 325 335
40 47 58 67 76 84 91 98 105 111 118 124 130 136 141 147 152 157 162 168
III (f) 13.65 9.75 8.04 7.03 6.35 5.85 5.46 5.15 4.89 4.67 4.49 4.32 4.18 4.06 3.94 3.84 3.75 3.66 3.58 3.51
65 93 115 134 152 168 182 197 210 223 236 247 259 272 282 293 304 314 325 335

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 170 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 12.74 9.01 7.36 6.37 5.70 5.20 4.82 4.50 4.25 4.03 3.84 3.68 3.53 3.40 3.29 3.18 3.09 3.00 2.92 2.85
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 12.74 9.01 7.36 6.37 5.70 5.20 4.82 4.50 4.25 4.03 3.84 3.68 3.53 3.40 3.29 3.18 3.09 3.00 2.92 2.85
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 12.74 9.01 7.36 6.37 5.70 5.20 4.82 4.50 4.25 4.03 3.84 3.68 3.53 3.40 3.29 3.18 3.09 3.00 2.92 2.85
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 12.74 9.01 7.36 6.37 5.70 5.20 4.82 4.50 4.25 4.03 3.84 3.68 3.53 3.40 3.29 3.18 3.09 3.00 2.92 2.85
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 12.74 9.01 7.36 6.37 5.70 5.20 4.82 4.50 4.25 4.03 3.84 3.68 3.53 3.40 3.29 3.18 3.09 3.00 2.92 2.85
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 12.74 9.01 7.36 6.37 5.70 5.20 4.82 4.50 4.25 4.03 3.84 3.68 3.53 3.40 3.29 3.18 3.09 3.00 2.92 2.85
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 12.74 9.01 7.36 6.37 5.70 5.20 4.82 4.50 4.25 4.03 3.84 3.68 3.53 3.40 3.29 3.18 3.09 3.00 2.92 2.85
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.34

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.35

KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 200 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 51 63 73 81 89 96 103 109 115 120 126 131 136 141 145 150 154 158 162
I, II, III (f) 16.51 11.96 9.76 8.45 7.56 6.90 6.39 5.98 5.64 5.35 5.10 4.88 4.69 4.52 4.37 4.23 4.10 3.98 3.88 3.78
Span
40 40 49 59 68 77 84 92 99 105 112 119 125 131 137 143 149 154 158 162
I (f) 11.77 8.91 7.65 6.90 6.37 5.94 5.60 5.33 5.10 4.91 4.75 4.60 4.48 4.36 4.26 4.17 4.08 3.98 3.88 3.78
60 77 99 119 137 153 168 183 198 211 224 238 250 262 274 287 298 308 317 325
40 40 49 59 68 77 84 92 99 105 112 119 125 131 137 143 149 154 158 162
Double
II (f) 11.77 8.91 7.65 6.90 6.37 5.94 5.60 5.33 5.10 4.91 4.75 4.60 4.48 4.36 4.26 4.17 4.08 3.98 3.88 3.78
Span 60 77 99 119 137 153 168 183 198 211 224 238 250 262 274 287 298 308 317 325
40 40 49 59 68 77 84 92 99 105 112 119 125 131 137 143 149 154 158 162
III (f) 11.77 8.91 7.65 6.90 6.37 5.94 5.60 5.33 5.10 4.91 4.75 4.60 4.48 4.36 4.26 4.17 4.08 3.98 3.88 3.78
60 77 99 119 137 153 168 183 198 211 224 238 250 262 274 287 298 308 317 325
40 45 56 66 74 82 89 96 103 109 115 121 127 133 138 144 149 154 158 162
I (f) 14.81 10.59 8.74 7.64 6.90 6.35 5.93 5.59 5.32 5.08 4.88 4.70 4.55 4.41 4.29 4.18 4.08 3.98 3.88 3.78
64 91 113 132 148 164 178 192 206 218 231 242 254 265 276 287 298 308 317 325

Load-span tables
40 45 56 66 74 82 89 96 103 109 115 121 127 133 138 144 149 154 158 162
Multi Span II (f) 14.81 10.59 8.74 7.64 6.90 6.35 5.93 5.59 5.32 5.08 4.88 4.70 4.55 4.41 4.29 4.18 4.08 3.98 3.88 3.78
64 91 113 132 148 164 178 192 206 218 231 242 254 265 276 287 298 308 317 325
40 45 56 66 74 82 89 96 103 109 115 121 127 133 138 144 149 154 158 162
III (f) 14.81 10.59 8.74 7.64 6.90 6.35 5.93 5.59 5.32 5.08 4.88 4.70 4.55 4.41 4.29 4.18 4.08 3.98 3.88 3.78
64 91 113 132 148 164 178 192 206 218 231 242 254 265 276 287 298 308 317 325

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 TF 1,150 mm – cover width

Wallpanel KS1150 TF 200 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 14.06 9.94 8.12 7.03 6.29 5.74 5.31 4.97 4.69 4.44 4.24 4.06 3.90 3.76 3.63 3.51 3.41 3.31 3.22 3.14
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 11.82 9.05 7.82 7.03 6.29 5.74 5.31 4.97 4.69 4.44 4.24 4.06 3.90 3.76 3.63 3.51 3.41 3.31 3.22 3.14
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 11.82 9.05 7.82 7.03 6.29 5.74 5.31 4.97 4.69 4.44 4.24 4.06 3.90 3.76 3.63 3.51 3.41 3.31 3.22 3.14
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 11.82 9.05 7.82 7.03 6.29 5.74 5.31 4.97 4.69 4.44 4.24 4.06 3.90 3.76 3.63 3.51 3.41 3.31 3.22 3.14
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 14.06 9.94 8.12 7.03 6.29 5.74 5.31 4.97 4.69 4.44 4.24 4.06 3.90 3.76 3.63 3.51 3.41 3.31 3.22 3.14
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 14.06 9.94 8.12 7.03 6.29 5.74 5.31 4.97 4.69 4.44 4.24 4.06 3.90 3.76 3.63 3.51 3.41 3.31 3.22 3.14
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 14.06 9.94 8.12 7.03 6.29 5.74 5.31 4.97 4.69 4.44 4.24 4.06 3.90 3.76 3.63 3.51 3.41 3.31 3.22 3.14
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.36

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.37

KS1150 FR, KS1000 FH 1,150 mm – cover width

Wallpanel KS1150 FR / FH 80 E/I 0.6 / 0.5 – according to EN 14509

1,000 mm – cover width

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 55 56 56 56 56 56 56 56 56 56 56 57 57 57 57 57 57 57 57
I, II, III (f) 8.71 6.64 4.44 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.89 0.84 0.79 0.74 0.71 0.67
Span
40 40 42 51 56 56 56 56 56 56 56 56 56 56 57 57 57 57 57 57
I (f) 4.36 3.63 3.27 3.04 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.89 0.84 0.79 0.74 0.71 0.67
60 61 83 103 113 113 113 113 113 113 113 113 113 113 114 114 114 114 114 114
40 40 42 51 56 56 56 56 56 56 56 56 56 56 57 57 57 57 57 57
Double
II (f) 4.36 3.63 3.27 3.04 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.89 0.84 0.79 0.74 0.71 0.67
Span 60 61 83 103 113 113 113 113 113 113 113 113 113 113 114 114 114 114 114 114
40 40 42 51 56 56 56 56 56 56 56 56 56 56 57 57 57 57 57 57
III (f) 4.36 3.63 3.27 3.04 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.89 0.84 0.79 0.74 0.71 0.67
60 60 83 103 113 113 113 113 113 113 113 113 113 113 114 114 114 114 114 114
40 41 52 56 56 56 56 56 56 56 56 56 56 56 57 57 57 57 57 57

Load-span tables
I (f) 6.68 4.88 4.10 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.89 0.84 0.79 0.74 0.71 0.67
60 83 104 113 113 113 113 113 113 113 113 113 113 113 114 114 114 114 114 114
40 47 52 56 56 56 56 56 56 56 56 56 56 56 57 57 57 57 57 57
Multi Span II (f) 6.68 4.88 4.10 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.89 0.84 0.79 0.74 0.71 0.67
60 83 104 113 113 113 113 113 113 113 113 113 113 113 114 114 114 114 114 114
40 47 52 56 56 56 56 56 56 56 56 56 56 56 57 57 57 57 57 57
III (f) 6.68 4.88 4.10 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.89 0.84 0.79 0.74 0.71 0.67
60 83 104 113 113 113 113 113 113 113 113 113 113 113 114 114 114 114 114 114

The span tables are valid for the wall systems KS1000 FR and KS1000 FH. Maximum spans in combination with secret fixing are not part of these calculations.
Regarding the secret fixing of KS1000 FH, please call your technical department.

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 FR, KS1000 FH 1,150 mm – cover width

Wallpanel KS1150 FR / FH 80 E/I 0.6 / 0.5 – according to EN 14509

1,000 mm – cover width

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 8.71 6.64 4.44 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 8.24 5.82 4.44 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 5.23 5.82 4.43 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 4.97 4.10 3.68 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 8.24 5.82 4.43 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 8.24 5.82 4.43 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 7.95 5.77 4.43 3.33 2.66 2.22 1.90 1.66 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span tables are valid for the wall systems KS1000 FR and KS1000 FH. Maximum spans in combination with secret fixing are not part of these calculations.
Regarding the secret fixing of KS1000 FH, please call your technical department.

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.38

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.39

KS1150 FR, KS1000 FH 1,150 mm – cover width

Wallpanel KS1150 FR / FH 100 E/I 0.6 / 0.5 – according to EN 14509

1,000 mm – cover width

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 44 57 56 57 57 57 56 57 57 56 56 56 56 56 57 57 57 57 57 57
I, II, III (f) 10.30 6.68 4.45 3.34 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
Span
40 40 49 56 56 56 56 57 57 57 57 57 56 56 56 56 56 56 56 56
I (f) 5.16 4.30 3.87 3.33 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 73 98 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113
40 40 49 56 56 56 56 57 57 57 57 57 56 56 56 56 56 56 56 56
Double
II (f) 5.16 4.30 3.87 3.33 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
Span 60 73 98 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113
40 40 49 56 56 56 56 57 57 57 57 57 56 56 56 56 56 56 56 56
III (f) 3.89 3.89 3.87 3.33 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 66 98 113 112 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113

Load-span tables
40 47 56 56 57 56 56 57 57 57 57 57 56 56 56 56 56 56 56 56
I (f) 7.55 5.56 4.44 3.33 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
64 97 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113
40 47 56 56 57 56 56 57 57 57 57 57 56 56 56 56 56 56 56 56
Multi Span II (f) 7.55 5.56 4.44 3.33 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
64 94 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113
40 47 56 56 57 56 56 57 57 57 57 57 56 56 56 56 56 56 56 56
III (f) 7.55 5.56 4.44 3.33 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
64 94 113 113 113 113 113 114 113 113 113 113 113 113 113 113 113 113 113 113

The span tables are valid for the wall systems KS1000 FR and KS1000 FH. Maximum spans in combination with secret fixing are not part of these calculations.
Regarding the secret fixing of KS1000 FH, please call your technical department.

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 FR, KS1000 FH 1,150 mm – cover width

Wallpanel KS1150 FR / FH 100 E/I 0.6 / 0.5 – according to EN 14509

1,000 mm – cover width

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 9.02 6.52 4.44 3.34 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
Span
40 40 40 40 56 56 56 57 57 57 57 57 56 56 56 56 56 56 56 56
I (f) 8.93 6.52 4.44 3.34 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113
40 40 40 40 56 56 56 57 57 57 57 57 56 56 56 56 56 56 56 56
Double
II (f) 6.39 5.07 4.44 3.34 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
Span 60 60 60 60 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113
40 40 40 40 40 56 56 57 57 57 57 57 56 56 56 56 56 56 56 56
III (f) 3.48 3.25 3.09 2.96 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 60 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 9.22 6.52 4.44 3.34 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 8.99 6.52 4.44 3.34 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 4.64 3.84 3.44 3.19 2.67 2.22 1.90 1.67 1.48 1.33 1.21 1.11 1.02 0.96 0.90 0.84 0.79 0.75 0.71 0.67
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span tables are valid for the wall systems KS1000 FR and KS1000 FH. Maximum spans in combination with secret fixing are not part of these calculations.
Regarding the secret fixing of KS1000 FH, please call your technical department.

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.40

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.41

KS1150 FR, KS1000 FH 1,150 mm – cover width

Wallpanel KS1150 FR / FH 120 E/I 0.6 / 0.5 – according to EN 14509

1,000 mm – cover width

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 48 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61
I, II, III (f) 11.31 7.21 4.81 3.60 2.88 2.40 2.06 1.80 1.60 1.44 1.31 1.20 1.10 1.03 0.97 0.91 0.85 0.81 0.76 0.72
Span
40 40 51 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61
I (f) 5.01 4.35 3.98 3.60 2.88 2.40 2.06 1.80 1.60 1.44 1.31 1.20 1.10 1.03 0.97 0.91 0.85 0.81 0.76 0.72
62 74 101 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122
40 40 51 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61
Double
II (f) 5.01 4.35 3.98 3.60 2.88 2.40 2.06 1.80 1.60 1.44 1.31 1.20 1.10 1.03 0.97 0.91 0.85 0.81 0.76 0.72
Span 62 74 101 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122
40 40 51 51 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61
III (f) 4.56 4.35 3.98 3.60 2.88 2.40 2.06 1.80 1.60 1.44 1.31 1.20 1.10 1.03 0.97 0.91 0.85 0.81 0.76 0.72
60 74 101 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122
40 46 59 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61

Load-span tables
I (f) 7.10 5.37 4.61 3.61 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.10 1.03 0.97 0.91 0.85 0.81 0.76 0.72
61 92 118 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122
40 46 59 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61
Multi Span II (f) 7.10 5.37 4.61 3.61 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.10 1.03 0.97 0.91 0.85 0.81 0.76 0.72
61 92 118 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122
40 46 59 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61
III (f) 7.10 5.37 4.61 3.61 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.10 1.03 0.97 0.91 0.85 0.81 0.76 0.72
68 92 118 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122

The span tables are valid for the wall systems KS1000 FR and KS1000 FH. Maximum spans in combination with secret fixing are not part of these calculations.
Regarding the secret fixing of KS1000 FH, please call your technical department.

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 FR, KS1000 FH 1,150 mm – cover width

Wallpanel KS1150 FR / FH 120 E/I 0.6 / 0.5 – according to EN 14509

1,000 mm – cover width

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 9.73 6.88 4.81 3.60 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.11 1.03 0.97 0.91 0.86 0.81 0.77 0.73
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 8.39 6.88 4.81 3.60 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.11 1.03 0.97 0.91 0.86 0.81 0.77 0.73
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 7.15 5.69 4.81 3.60 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.11 1.03 0.97 0.91 0.86 0.81 0.77 0.73
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 4.03 3.74 3.55 3.40 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.11 1.03 0.97 0.91 0.86 0.81 0.77 0.73
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 9.73 6.88 4.81 3.61 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.11 1.03 0.97 0.91 0.86 0.81 0.77 0.73
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 9.73 6.88 4.81 3.61 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.11 1.03 0.97 0.91 0.86 0.81 0.77 0.73
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 5.25 4.34 3.89 3.61 2.89 2.41 2.06 1.80 1.60 1.44 1.31 1.20 1.11 1.03 0.97 0.91 0.86 0.81 0.77 0.73
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span tables are valid for the wall systems KS1000 FR and KS1000 FH. Maximum spans in combination with secret fixing are not part of these calculations.
Regarding the secret fixing of KS1000 FH, please call your technical department.

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.42

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.43

KS1150 FR, KS1000 FH 1,150 mm – cover width

Wallpanel KS1150 FR / FH 150 E/I 0.6 / 0.5 – according to EN 14509

1,000 mm – cover width

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 54 64 64 64 64 64 64 64 63 63 63 63 63 63 64 64 64 64 64 64
I, II, III (f) 12.66 7.52 5.02 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.79 0.76
Span
40 40 52 64 64 64 64 64 63 63 63 63 63 63 64 64 64 64 64 64
I (f) 4.85 4.40 4.12 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.79 0.76
60 74 105 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127
40 40 52 64 64 64 64 64 63 63 63 63 63 63 64 64 64 64 64 64
Double
II (f) 4.85 4.40 4.12 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.79 0.76
Span 60 74 105 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127
40 40 52 64 64 64 64 64 63 63 63 63 63 63 64 64 64 64 64 64
III (f) 4.85 4.40 4.12 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.79 0.76
60 74 105 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127
40 41 52 64 64 64 64 64 63 63 63 63 63 63 64 64 64 64 64 64

Load-span tables
I (f) 5.95 4.86 4.34 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.79 0.76
60 82 105 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127
40 41 52 64 64 64 64 64 63 63 63 63 63 63 64 64 64 64 64 64
Multi Span II (f) 5.95 4.86 4.34 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.79 0.76
60 82 105 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127
40 41 52 64 64 64 64 64 63 63 63 63 63 63 64 64 64 64 64 64
III (f) 5.95 4.86 4.34 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.79 0.76
60 82 105 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127

The span tables are valid for the wall systems KS1000 FR and KS1000 FH. Maximum spans in combination with secret fixing are not part of these calculations.
Regarding the secret fixing of KS1000 FH, please call your technical department.

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1150 FR, KS1000 FH 1,150 mm – cover width

Wallpanel KS1150 FR / FH 150 E/I 0.6 / 0.5 – according to EN 14509

1,000 mm – cover width

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I, II, III (f) 10.20 7.21 5.02 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.80 0.76
Span
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 5.90 5.90 5.02 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.80 0.76
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Double
II (f) 5.90 5.90 5.02 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.80 0.76
Span 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 4.95 4.56 4.31 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.80 0.76
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
I (f) 10.20 7.21 5.02 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.80 0.76
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Multi Span II (f) 10.20 7.21 5.02 3.76 3.01 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.80 0.76
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
III (f) 6.17 5.12 4.60 3.76 5.29 2.51 2.15 1.88 1.67 1.50 1.36 1.25 1.16 1.07 1.00 0.95 0.89 0.84 0.80 0.76
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60

The span tables are valid for the wall systems KS1000 FR and KS1000 FH. Maximum spans in combination with secret fixing are not part of these calculations.
Regarding the secret fixing of KS1000 FH, please call your technical department.

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.44

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.45

KS1000 AWP
1,000 mm – cover width
Wallpanel KS1000 AWP 60 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 40 40 45 49 53 56 58 58 58 58 58 58 58 58 58 58 58
I, II, III (f) 6.61 5.53 4.85 4.40 4.07 3.77 3.53 3.34 3.17 2.96 2.69 2.46 2.28 2.11 1.97 1.85 1.74 1.64 1.56 1.48
Span
40 40 40 40 40 40 41 44 47 51 54 57 58 58 58 58 58 58 58 58
I (f) 6.28 4.71 4.03 3.62 3.34 3.13 2.95 2.80 2.68 2.58 2.49 2.41 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 60 66 74 81 88 95 102 108 114 116 116 116 116 116 116 116 116
40 40 40 40 40 40 41 44 47 51 54 57 58 58 58 58 58 58 58 58
Double
II (f) 6.28 4.71 4.03 3.62 3.34 3.13 2.95 2.80 2.68 2.58 2.49 2.41 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
Span 60 60 60 60 66 74 81 88 95 102 108 114 116 116 116 116 116 116 116 116
40 40 40 40 40 40 41 44 47 51 54 57 58 58 58 58 58 58 58 58
III (f) 6.28 4.71 4.03 3.62 3.34 3.13 2.95 2.80 2.68 2.58 2.49 2.41 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 60 66 74 81 88 95 102 108 114 116 116 116 116 116 116 116 116
40 40 40 40 40 40 44 47 50 53 56 58 58 58 58 58 58 58 58 58
I (f) 8.02 5.72 4.71 4.12 3.71 3.41 3.18 2.99 2.84 2.71 2.60 2.46 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 65 73 81 88 94 101 107 113 116 116 116 116 116 116 116 116 116

Load-span tables
40 40 40 40 40 40 44 47 50 53 56 58 58 58 58 58 58 58 58 58
Multi Span II (f) 8.02 5.72 4.71 4.12 3.71 3.41 3.18 2.99 2.84 2.71 2.60 2.46 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 65 73 81 88 94 101 107 113 116 116 116 116 116 116 116 116 116
40 40 40 40 40 40 44 47 50 53 56 58 58 58 58 58 58 58 58 58
III (f) 8.02 5.72 4.71 4.12 3.71 3.41 3.18 2.99 2.84 2.71 2.60 2.46 2.27 2.11 1.97 1.85 1.74 1.64 1.56 1.48
60 60 60 65 73 81 88 94 101 107 113 116 116 116 116 116 116 116 116 116

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1000 AWP
1,000 mm – cover width
Wallpanel KS1000 AWP 60 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single A B B B B B B B B B B B B B B B B B B B
I, II, III (f) 5.62 4.97 3.57 2.68 2.14 1.79 1.53 1.34 1.19 1.07 0.98 0.89 0.82 0.77 0.72 0.67 0.63 0.60 0.56 0.54
Span
A A A A B B B B B B B B B B B B B B B B
I (f) 6.76 3.12 2.03 1.54 1.27 1.09 0.97 0.87 0.79 0.72 0.67 0.62 0.58 0.55 0.51 0.49 0.46 0.44 0.42 0.40
B B B B B B B B B B B B B B B B B B B B
A A A A A A A A A B B B B B B B B B B B
Double
II (f) 6.45 2.82 1.81 1.39 1.15 1.00 0.89 0.80 0.73 0.68 0.63 0.59 0.55 0.52 0.49 0.46 0.44 0.42 040 0.39
Span B B B B B B B B B B B B B B B B B B B B
A A A A A A A A A A A A A A A A A A A A
III (f) 5.92 1.60 1.19 1.02 0.94 0.86 0.79 0.72 0.66 0.61 0.57 0.54 0.51 0.48 0.46 0.43 0.41 0.39 0.38 0.36
B B B B B B B B B B B B B B B B B B B B
A A B B B B B B B B B B B B B B B B B B
I (f) 6.97 3.97 2.57 1.89 1.49 1.24 1.03 0.88 0.79 0.72 0.66 0.61 0.57 0.54 0.50 0.48 0.45 0.43 0.41 0.39
B B B B B B B B B B B B B B B B B B B B
A A A B B B B B B B B B B B B B B B B B
Multi Span II (f) 6.97 3.86 2.46 1.78 1.40 1.16 1.00 0.89 0.79 0.72 0.66 0.61 0.57 0.54 0.50 0.48 0.45 0.43 0.41 0.39
B B B B B B B B B B B B B B B B B B B B
A A A B B B B B B B B B B B B B B B B B
III (f) 6.97 3.68 2.28 1.62 1.26 1.04 0.91 0.81 0.73 0.66 0.61 0.57 0.53 0.50 0.47 0.45 0.42 0.40 0.39 0.37
B B B B B B B B B B B B B B B B B B B B

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.46

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.47

KS1000 AWP
1,000 mm – cover width
Wallpanel KS1000 AWP 80 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 40 43 49 54 59 63 57 70 74 77 78 78 78 78 78 78 78 78
I, II, III (f) 8.39 6.86 6.01 5.46 5.00 4.61 4.27 3.99 3.76 3.57 3.40 3.26 3.05 2.84 2.64 2.48 2.33 2.20 2.09 1.98
Span
40 40 40 40 40 43 47 51 55 59 62 66 69 73 76 78 78 78 78 78
I (f) 7.27 5.46 4.66 4.19 3.87 3.63 3.42 3.25 3.10 2.98 2.88 2.79 2.71 2.64 2.58 2.48 2.33 2.20 2.09 1.98
60 60 60 66 76 86 94 102 110 117 125 132 139 146 152 156 156 156 156 156
40 40 40 40 40 43 47 51 55 59 62 66 69 73 76 78 78 78 78 78
Double
II (f) 7.27 5.46 4.66 4.19 3.87 3.63 3.42 3.25 3.10 2.98 2.88 2.79 2.71 2.64 2.58 2.48 2.33 2.20 2.09 1.98
Span 60 60 60 66 76 86 94 102 110 117 125 132 139 146 152 156 156 156 156 156
40 40 40 40 40 43 47 51 55 59 62 66 69 73 76 78 78 78 78 78
III (f) 7.27 5.46 4.66 4.19 3.87 3.63 3.42 3.25 3.10 2.98 2.88 2.79 2.71 2.64 2.58 2.48 2.33 2.20 2.09 1.98
60 60 60 66 76 86 94 102 110 117 125 132 139 146 152 156 156 156 156 156
40 40 40 40 42 47 51 55 58 62 65 69 72 75 78 78 78 78 78 78
I (f) 9.29 6.63 5.46 4.77 4.30 3.95 3.68 3.47 3.29 3.14 3.01 2.90 2.80 2.72 2.64 2.48 2.33 2.20 2.09 1.98
60 60 64 75 85 93 102 110 117 124 130 137 144 150 156 156 156 156 156 156

Load-span tables
40 40 40 40 42 47 51 55 58 62 65 69 72 75 78 78 78 78 78 78
Multi Span II (f) 9.29 6.63 5.46 4.77 4.30 3.95 3.68 3.47 3.29 3.14 3.01 2.90 2.80 2.72 2.64 2.48 2.33 2.20 2.09 1.98
60 60 64 75 85 93 102 110 117 124 130 137 144 150 156 156 156 156 156 156
40 40 40 40 42 47 51 55 58 62 65 69 72 75 78 78 78 78 78 78
III (f) 9.29 6.63 5.46 4.77 4.30 3.95 3.68 3.47 3.29 3.14 3.01 2.90 2.80 2.72 2.64 2.48 2.33 2.20 2.09 1.98
60 60 64 75 85 93 102 110 117 124 130 137 144 150 156 156 156 156 156 156

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1000 AWP
1,000 mm – cover width
Wallpanel KS1000 AWP 80 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single B B B B B B B B B B B B B B B B B B B B
I, II, III (f) 6.95 5.71 4.20 3.15 2.52 2.10 1.80 1.57 1.40 1.26 1.14 1.05 0.97 0.90 0.84 0.79 0.74 0.70 0.66 0.63
Span
A A A B B B B B B B B B B B B B B B B B
I (f) 7.95 3.68 2.40 1.82 1.49 1.28 1.12 1.01 0.92 0.85 0.78 0.73 0.68 0.64 0.60 0.57 0.54 0.52 0.49 0.47
B B B B B B B B B B B B B B B B B B B B
B B B B B B B B B B B B B B B B B B B B
Double
II (f) 7.60 3.34 2.14 1.64 1.36 1.17 1.04 0.95 0.86 0.79 0.74 0.69 0.65 0.61 0.58 0.55 0.52 0.50 0.47 0.45
Span B B B B B B B B B B B B B B B B B B B B
B B B B B B B B B B B B B B B B B B B B
III (f) 7.00 1.98 1.42 1.22 1.08 1.00 0.93 0.85 0.78 0.72 0.67 0.63 0.60 0.56 0.54 0.51 0.49 0.46 0.44 0.43
B B B B B B B B B B B B B B B B B B B B
A A A A A A B B B B B B B B B B B B B B
I (f) 8.08 4.67 3.02 2.22 1.76 1.46 1.25 1.05 0.94 0.86 0.78 0.72 0.67 0.63 0.59 0.56 0.53 0.51 0.49 0.47
B B B B B B B B B B B B B B B B B B B B
A A A A A A B B B B B B B B B B B B B B
Multi Span II (f) 8.08 4.54 2.90 2.10 1.65 1.37 1.18 1.03 0.94 0.85 0.78 0.72 0.67 0.63 0.59 0.56 0.53 0.51 0.48 0.46
B B B B B B B B B B B B B B B B B B B B
B B B B B B B B B B B B B B B B B B B B
III (f) 8.08 4.34 2.69 1.92 1.49 1.23 1.06 0.95 0.86 0.78 0.72 0.67 0.63 0.59 0.55 0.53 0.50 0.48 0.45 0.44
B B B B B B B B B B B B B B B B B B B B

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.48

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.49

KS1000 AWP
1,000 mm – cover width
Wallpanel KS1000 AWP 100 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 40 50 60 67 73 79 84 90 94 99 103 108 108 108 108 108 108 109 109
I, II, III (f) 9.99 8.05 7.05 6.32 5.65 5.16 4.78 4.47 4.21 4.00 3.81 3.65 3.51 3.28 3.06 2.87 2.70 2.55 2.42 2.30
Span
40 40 40 45 52 58 64 70 75 80 85 90 95 99 104 108 108 108 109 109
I (f) 8.20 6.17 5.28 4.76 4.39 4.11 3.87 3.68 3.52 3.38 3.27 3.17 3.08 3.00 2.93 2.86 2.70 2.55 2.42 2.30
60 60 75 90 104 117 128 139 150 160 170 180 190 198 208 216 217 217 217 217
40 40 40 45 52 58 64 70 75 80 85 90 95 99 104 108 108 108 109 109
Double
II (f) 8.20 6.17 5.28 4.76 4.39 4.11 3.87 3.68 3.52 3.38 3.27 3.17 3.08 3.00 2.93 2.86 2.70 2.55 2.42 2.30
Span 60 60 75 90 104 117 128 139 150 160 170 180 190 198 208 216 217 217 217 217
40 40 40 45 52 58 64 70 75 80 85 90 95 99 104 108 108 108 109 109
III (f) 8.20 6.17 5.28 4.76 4.39 4.11 3.87 3.68 3.52 3.38 3.27 3.17 3.08 3.00 2.93 2.86 2.70 2.55 2.42 2.30
60 60 75 90 104 117 128 139 150 160 170 180 190 198 208 216 217 217 217 217
40 40 43 51 57 63 68 74 79 84 88 93 97 102 106 108 108 108 109 109
I (f) 10.42 7.44 6.13 5.35 4.83 4.44 4.14 3.90 3.71 3.54 3.40 3.27 3.16 3.07 2.98 2.87 2.70 2.55 2.42 2.30
60 70 87 101 114 126 137 147 158 167 177 185 194 203 212 217 217 217 217 217

Load-span tables
40 40 43 51 57 63 68 74 79 84 88 93 97 102 106 108 108 108 109 109
Multi Span II (f) 10.42 7.44 6.13 5.35 4.83 4.44 4.14 3.90 3.71 3.54 3.40 3.27 3.16 3.07 2.98 2.87 2.70 2.55 2.42 2.30
60 70 87 101 114 126 137 147 158 167 177 185 194 203 212 217 217 217 217 217
40 40 43 51 57 63 68 74 79 84 88 93 97 102 106 108 108 108 109 109
III (f) 10.42 7.44 6.13 5.35 4.83 4.44 4.14 3.90 3.71 3.54 3.40 3.27 3.16 3.07 2.98 2.87 2.70 2.55 2.42 2.30
60 70 87 101 114 126 137 147 158 167 177 185 194 203 212 217 217 217 217 217

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1000 AWP
1,000 mm – cover width
Wallpanel KS1000 AWP 100 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single A B B B B B B B B B B B B B B B B B B B
I, II, III (f) 8.38 6.40 4.84 3.63 2.90 2.42 2.07 1.81 1.61 1.45 1.32 1.21 1.12 1.04 0.97 0.91 0.85 0.81 0.76 0.72
Span
A A B B B B B B B B B B B B B B B B B B
I (f) 9.05 4.29 2.80 2.13 1.75 1.50 1.32 1.18 1.07 0.99 0.91 0.85 0.80 0.75 0.70 0.67 0.63 0.60 0.57 0.55
B B B B B B B B B B B B B B B B B B B B
A A B B B B B B B B B B B B B B B B 91 91
Double
II (f) 8.81 3.93 2.54 1.94 1.60 1.38 1.22 1.10 1.00 0.93 0.86 0.81 0.76 0.71 0.67 0.64 0.61 0.58 0.55 0.53
Span B B B B B B B B B B B B B B B B B B 181 181
A A A A A B B B B B B B B B B B B B B B
III (f) 8.17 3.18 1.85 1.54 1.35 1.22 1.10 1.00 0.92 0.85 0.80 0.75 0.70 0.66 0.63 0.60 0.57 0.54 0.52 0.50
B B B B B B B B B B B B B B B B B B B B
A B B B B B B B B B B B B B B B B B B B
I (f) 9.05 5.38 3.50 2.58 2.04 1.69 1.45 1.28 1.14 1.02 0.94 0.86 0.60 0.75 0.71 0.67 0.63 0.60 0.58 0.55
B B B B B B B B B B B B B B B B B B B B
A B B B B B B B B B B B B B B B B B B B
Multi Span II (f) 9.05 5.24 3.36 2.45 1.93 1.60 1.37 1.21 1.08 0.99 0.91 0.84 0.79 0.74 0.69 0.65 0.62 0.59 0.56 0.54
B B B B B B B B B B B B B B B B B B B B
A B B B B B B B B B B B B B B B B B B B
III (f) 9.05 5.02 3.14 2.25 1.76 1.45 1.25 1.10 1.00 0.92 0.85 0.78 0.73 0.69 0.65 0.62 0.58 0.56 0.53 0.51
B B B B B B B B B B B B B B B B B B B B

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.50

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.51

KS1000 AWP
1,000 mm – cover width
Wallpanel KS1000 AWP 120 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic downwards load, e.g. wind pressure [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single 40 54 71 82 92 100 108 116 123 129 136 142 148 150 150 150 150 150 150 150
I, II, III (f) 11.38 9.17 7.99 6.93 6.20 5.66 5.24 4.90 4.92 4.38 4.18 4.00 3.85 3.62 3.38 3.17 2.98 2.82 2.67 2.53
Span
40 40 52 62 71 81 89 96 104 111 118 125 131 138 144 150 150 150 150 150
I (f) 9.06 6.85 5.87 5.29 4.89 4.56 4.29 4.08 3.91 3.76 3.64 3.52 3.42 3.34 3.26 3.17 2.98 2.82 2.67 2.53
60 81 104 125 144 162 177 193 208 222 236 249 263 276 289 300 300 300 300 300
40 40 52 62 71 81 89 96 104 111 118 125 131 138 144 150 150 150 150 150
Double
II (f) 9.06 6.85 5.87 5.29 4.89 4.56 4.29 4.08 3.91 3.76 3.64 3.52 3.42 3.34 3.26 3.17 2.98 2.82 2.67 2.53
Span 60 81 104 125 144 162 177 193 208 222 236 249 263 276 289 300 300 300 300 300
40 40 52 62 71 81 89 96 104 111 118 125 131 138 144 150 150 150 150 150
III (f) 9.06 6.85 5.87 5.29 4.89 4.56 4.29 4.08 3.91 3.76 3.64 3.52 3.42 3.34 3.26 3.17 2.98 2.82 2.67 2.53
60 81 104 125 144 162 177 193 208 222 236 249 263 276 289 300 300 300 300 300
40 48 60 70 79 87 94 102 109 115 122 128 134 140 146 150 150 150 150 150
I (f) 11.44 8.17 6.74 5.89 5.32 4.90 4.57 4.31 4.09 3.91 3.75 3.62 3.50 3.39 3.30 3.17 2.98 2.82 2.67 2.53
68 97 120 139 157 174 189 204 217 231 244 257 269 280 292 300 300 300 300 300

Load-span tables
40 48 60 70 79 87 94 102 109 115 122 128 134 140 146 150 150 150 150 150
Multi Span II (f) 11.44 8.17 6.74 5.89 5.32 4.90 4.57 4.31 4.09 3.91 3.75 3.62 3.50 3.39 3.30 3.17 2.98 2.82 2.67 2.53
68 97 120 139 157 174 189 204 217 231 244 257 269 280 292 300 300 300 300 300
40 48 60 70 79 87 94 102 109 115 122 128 134 140 146 150 150 150 150 150
III (f) 11.44 8.17 6.74 5.89 5.32 4.90 4.57 4.31 4.09 3.91 3.75 3.62 3.50 3.39 3.30 3.17 2.98 2.82 2.67 2.53
68 97 120 139 157 174 189 204 217 231 244 257 269 280 292 300 300 300 300 300

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.

5.
5.
Load-span tables
KS1000 AWP
1,000 mm – cover width
Wallpanel KS1000 AWP 120 E/I 0.6 / 0.4 – according to EN 14509

Colour characteristic uplifting load, e.g. Wind suction [kN/m2]


System
group 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
Single A B B B B B B B B B B B B B B B B B B B
I, II, III (f) 9.74 7.02 5.46 4.09 3.28 2.73 2.34 2.05 1.82 1.64 1.49 1.36 1.26 1.17 1.09 1.02 0.98 0.91 0.86 0.82
Span
A B B B B B B B B B B B B B B B B B B B
I (f) 9.92 4.92 3.24 2.46 2.02 1.72 1.52 1.36 1.23 1.12 1.04 0.98 0.91 0.86 0.81 0.76 0.72 0.69 0.66 0.63
B B B B B B B B B B B B B B B B B B B B
A A B B B B B B B B B B B B B B B B 91 91
Double
II (f) 9.92 4.55 2.96 2.26 1.86 1.60 1.42 1.27 1.16 1.06 1.00 0.93 0.87 0.82 0.77 0.73 0.70 0.66 0.63 0.61
Span B B B B B B B B B B B B B B B B B B 181 181
A A A B B B B B B B B B B B B B B B B B
III (f) 9.39 3.92 2.40 1.92 1.65 1.44 1.28 1.16 1.06 0.99 0.92 0.86 0.81 0.77 0.73 0.69 0.66 0.63 0.60 0.58
B B B B B B B B B B B B B B B B B B B B
A B B B B B B B B B B B B B B B B B B B
I (f) 9.92 6.10 3.98 2.93 2.33 1.94 1.66 1.46 1.31 1.18 1.08 1.00 0.94 0.88 0.82 0.78 0.74 0.70 0.66 0.63
B B B B B B B B B B B B B B B B B B B B
A B B B B B B B B B B B B B B B B B B B
Multi Span II (f) 9.92 5.96 3.83 2.80 2.21 1.84 1.58 1.39 1.24 1.13 1.04 0.97 0.90 0.84 0.79 0.75 0.71 0.67 0.64 0.61
B B B B B B B B B B B B B B B B B B B B
A B B B B B B B B B B B B B B B B B B B
III (f) 9.92 5.73 3.60 2.60 2.04 1.68 1.45 1.28 1.15 1.05 0.98 0.91 0.85 0.79 0.75 0.71 0.67 0.64 0.61 0.59
B B B B B B B B B B B B B B B B B B B B

The span widths are calculated according to the proof procedures given in EN 14509. All loads are regarded as characteristic loads. Element dead loads have been
5.52

considered in the span calculations. Possible errors and omissions excepted. Please consider, that this table does not replace a verifiable structural design.
5.53

KS1000 X-DEK d

D
Roofpanel KS1000 XD TR20/TR27
335 mm 333 mm 332 mm
1,000 mm

Bottom deck All loads in kN/m2 for given span in meters


System Core thickness Load Case Load Type
gauge [mm] 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00
Downwards 10.38 8.26 6.85 5.36 4.70 3.56 2.76 2.28 1.92
ULS
Upwards 15.78 10.16 7.10 5.25 3.33 2.42 1.79 1.53 1.33
XD 80
Downwards 6.92 5.51 4.57 3.40 2.62 1.76 1.22 0.93 0.73
SLS
Upwards 10.52 6.77 4.73 3.50 2.50 1.73 1.24 0.95 0.74
Single Span
Downwards 10.38 8.26 6.85 5.36 4.70 3.64 2.89 2.38 1.99
ULS
Upwards 15.78 10.16 7.10 5.25 3.43 2.56 1.95 1.49 1.15
XD 100
Downwards 6.92 5.51 4.57 3.40 2.62 1.78 1.25 0.96 0.76
SLS
Upwards 10.52 6.77 4.73 3.50 2.35 1.72 1.30 0.97 0.74
0.9
Downwards 9.99 7.05 5.20 3.98 2.85 2.32 1.93 1.56 1.29
ULS
Upwards 14.87 10.23 7.50 5.70 3.10 2.39 1.89 1.70 1.55
XD 80
Downwards 6.66 4.70 3.47 2.65 5.47 4.11 3.19 2.51 2.02
SLS

Load-span tables
Upwards 9.91 6.82 5.00 3.80 4.98 3.82 3.01 2.35 1.88
Double Span
Downwards 9.99 7.05 5.20 3.98 3.19 2.45 1.93 1.55 1.27
ULS
Upwards 14.87 10.23 7.50 5.70 3.11 2.75 2.46 2.16 1.92
XD 100
Downwards 6.66 4.70 3.47 2.65 5.47 3.91 2.90 2.40 2.02
SLS
Upwards 9.91 6.82 5.00 3.80 4.66 3.70 3.01 2.38 1.92

Remarks: ULS – Ultimate Limit State – indicated loads should be compared with factored (design) loads, SLS – Serviceability Limit State – indicated loads should be compared with
characteristic(un-factored) loads. Maximum permissible deflection limit (SLS): L / 200.
The minimum width of supports: For the span < 4.00 meters: For SINGLE SPAN at ends – 50 mm, For DOUBLE SPAN at ends – 90 mm, intermediate 160 mm
For the span ≥ 4.00 meters: For SINGLE SPAN at ends – 40 mm, For DOUBLE SPAN at ends – 40 mm, intermediate 120 mm
The dead load of panels is included in the above figures

5.
5.
Load-span tables
KS1000 X-DEK d

D
Roofpanel KS1000 XD TR20/TR27
335 mm 333 mm 332 mm
1,000 mm

Bottom deck All loads in kN/m2 for given span in meters


System Core thickness Load Case Load Type
gauge [mm] 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50
Downwards 15.60 12.44 9.92 7.22 5.57 4.37 3.48 2.84 2.34 1.97
ULS
Upwards 21.06 13.55 9.45 6.99 4.83 3.85 3.15 2.57 2.23 1.92
XD 80
Downwards 10.40 8.29 6.61 4.81 2.89 1.99 1.39 1.02 0.73 0.54
SLS
Upwards 14.04 9.03 6.30 4.55 3.10 2.20 1.67 1.30 1.04 0.86
Single Span
Downwards 15.60 12.44 9.92 7.22 5.67 4.45 3.54 2.90 2.38 2.01
ULS
Upwards 21.06 13.55 9.45 6.99 4.83 3.85 3.15 2.57 2.23 1.92
XD 100
Downwards 10.40 8.29 6.61 4.81 2.94 2.03 1.42 1.04 0.74 0.55
SLS
Upwards 14.04 9.03 6.30 4.55 3.10 2.20 1.67 1.30 1.04 0.86
1.1
Downwards 14.09 9.86 7.25 5.52 4.32 3.45 2.81 2.31 1.92 1.62
ULS
Upwards 21.80 14.76 10.32 7.62 5.29 4.19 3.42 2.86 2.42 2.09
XD 80
Downwards 9.39 6.57 4.83 3.68 5.47 4.11 3.19 2.51 2.02 1.19
SLS
Upwards 14.53 9.85 6.88 5.08 4.98 3.82 3.01 2.35 1.88 1.71
Double Span
Downwards 14.09 9.86 7.25 5.52 4.32 3.45 2.81 2.31 1.92 1.62
ULS
Upwards 21.80 14.76 10.32 7.62 5.29 4.19 3.42 2.86 2.42 2.09
XD 100
Downwards 9.39 6.57 4.83 3.68 5.47 3.91 2.90 2.40 2.02 1.24
SLS
Upwards 14.53 9.85 6.88 5.08 4.66 3.70 3.01 2.38 1.92 1.78

Remarks: ULS – Ultimate Limit State – indicated loads should be compared with factored (design) loads, SLS – Serviceability Limit State – indicated loads should be compared with
characteristic(un-factored) loads. Maximum permissible deflection limit (SLS): L / 200.
The minimum width of supports: For the span < 4.00 meters: For SINGLE SPAN at ends – 50 mm, For DOUBLE SPAN at ends – 90 mm, intermediate 160 mm
5.54

For the span ≥ 4.00 meters: For SINGLE SPAN at ends – 40 mm, For DOUBLE SPAN at ends – 40 mm, intermediate 120 mm
The dead load of panels is included in the above figures
5.55

KS1000 X-DEK d

D
Roofpanel KS1000 XD –
ext. Steel 0.70 mm (Minibox-profiled) / int. Steel 0.9 mm 335 mm 333 mm 332 mm
1,000 mm

All loads in kN/m2 for given span in meters


System Core thickness Load Case
1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50
Downwards 19.68 12.02 8.47 6.23 4.79 3.82 3.12 2.65 2.15 1.70 1.35 1.05 0.80
XD 80 Upwards 22.63 13.72 9.49 7.09 5.57 4.52 3.77 3.16 2.56 2.12 1.78 1.52 1.28
amin [mm] 141 115 102 91 82 76 70 68 60 55 49 41 40
Single Span
Downwards 19.53 12.48 8.96 6.61 5.15 4.15 3.45 2.91 2.47 2.01 1.63 1.31 1.02
XD 100 Upwards 23.38 14.45 10.17 7.72 6.15 5.06 4.26 3.61 2.95 2.46 2.07 1.77 1.53
amin [mm] 140 120 108 97 88 82 77 73 68 63 56 44 43
Downwards 19.67 12.02 8.47 6.23 4.79 3.82 3.13 2.61 2.22 1.90 1.62 1.40 1.20
Upwards 22.62 13.72 9.49 7.09 5.57 4.52 3.77 3.19 2.75 2.40 2.11 1.87 1.68
XD 80
amin [mm] 141 115 102 91 82 76 70 66 62 59 56 52 49
bmin [mm] 282 231 205 182 165 152 141 132 125 118 111 105 99
Double Span
Downwards 20.15 12.48 8.96 6.62 5.15 4.03 3.44 2.89 2.47 2.02 1.71 1.47 1.27

Load-span tables
Upwards 23.38 14.45 10.17 7.72 6.15 5.06 4.26 3.65 3.16 2.76 2.44 2.18 1.95
XD 100
amin [mm] 144 120 108 97 88 80 77 73 69 63 58 55 52
bmin [mm] 288 240 216 193 177 160 155 146 139 126 117 110 104

Remarks: The above values of loads are characteristic. For Each value individual and combined load cases with appropriate load factors and temperatures have been considered.
For Intermediate values linear interpolation may be used. Values have been calculated using the limit state method according to EN 14509, taking imposed loads and temperature into account.
Maximum permissible deflection limit: downwards and upwards – L / 200
amin – the minimum width of end supports, bmin – the minimum width of intermediate supports
The dead load of panels is included in the above figures

5.
5.
Load-span tables
KS1000 X-DEK d

D
Roofpanel KS1000 XD –
ext. Steel 0.70 mm (Minibox-profiled) / int. Steel 1.1 mm 335 mm 333 mm 332 mm
1,000 mm

All loads in kN/m2 for given span in meters


System Core thickness Load Case
1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50
Downwards 23.66 14.22 9.85 7.41 5.66 4.50 3.67 3.05 2.38 1.87 1.49 1.16 0.89
XD 80 Upwards 27.25 16.37 11.21 8.31 6.50 5.26 4.36 3.51 2.84 2.35 1.97 1.68 1.45
amin [mm] 169 136 119 108 97 89 83 77 67 59 43 45 40
Single Span
Downwards 24.12 14.69 10.32 7.79 6.03 4.85 4.00 3.37 2.75 2.20 1.78 1.45 1.14
XD 100 Upwards 28.01 17.09 11.90 8.97 7.10 5.82 4.88 3.98 3.24 2.69 2.27 1.94 1.68
amin [mm] 173 141 125 114 103 96 90 85 77 69 61 55 48
Downwards 23.66 14.22 9.85 7.41 5.66 4.49 3.67 3.05 2.58 2.21 1.91 1.66 1.46
Upwards 27.27 16.36 11.21 8.31 6.50 5.26 4.36 3.70 3.18 2.77 2.28 2.16 1.93
XD 80
amin [mm] 169 136 119 108 97 89 83 77 73 69 65 62 59
bmin [mm] 338 273 238 216 194 178 165 154 145 137 130 124 119
Double Span
Downwards 24.13 14.69 10.32 7.79 6.03 4.84 4.00 3.36 2.87 2.42 2.07 1.79 1.56
Upwards 28.03 17.09 11.90 8.97 7.10 5.82 4.88 4.17 3.61 3.16 2.80 2.49 2.24
XD 100
amin [mm] 173 141 125 114 103 96 90 85 80 75 70 66 63
bmin [mm] 345 282 249 227 207 191 179 169 161 150 140 132 126

Remarks: The above values of loads are characteristic. For Each value individual and combined load cases with appropriate load factors and temperatures have been considered.
For Intermediate values linear interpolation may be used. Values have been calculated using the limit state method according to EN 14509, taking imposed loads and temperature into account.
Maximum permissible deflection limit: downwards and upwards – L / 200
5.56

amin – the minimum width of end supports, bmin – the minimum width of intermediate supports
The dead load of panels is included in the above figures