PHL-1
Cab Amminition safety racks Rounds falling out of racks 1. Injury to personnel/posible loss of life 2.
Damage to projectile
PHL-2
Howitzer Ammunition M82 primer failure to function 1. Howitzer fails to fire resulting in at least a five minute delay in the
mission or possible mission failure
PHL-3
Howitzer Ammunition M4 Series Propelling Charges failure to function 1Howitzer fails to fire resulting in 5mi delay 2. Round falls long or
short of target 3. possible injury/loss of life to personnel
PHL-4
Howitzer Engine The engine produces carbon monoxcide 1. can cause illness, permanent neurological damage, loss of life
PHL-5
Howitzer Fuel fuel leaks into the hul of howitzer could cause fire resulting in loss of equipment, injury to personnel or
loss of life
PHL-6
Howitzer radio comunnication system Loss communication during fire mission failure to receive emergency voice commands
PHL-7
Howitzer Battery led acid battery gases can explode Gases can explode, causing injury, loss of life and damage or loss of
equipment
PHL-8
Howitzer computer Improper installation will result in low level shock to personnel
PHL-9
Howitzer computer computer displays ghost data Could result in round fired inadvertently
PHL-10
System Element Type:
Hazardous Functions
No. System Item
Hazard Hazard Effects
Howitzer gunner display unit(GDU) GDU fails to display correct data Crew will not receive data to conduct mission
PHL-11
Howitzer Ammunition- Fuze verable time Premature or late funtioning of fuze up to 1 sec Round could detonate as close as 300 meters from tube potential
(VT) enjury to personnel and equipment
PHL-12
Howitzer Ammunition- Fuze Mechinical Premature or late funtioning of fuze up to .10 sec Potential injury to personel and equipment
time (MT)
PHL-13
Howitzer Ammunition-FuzePoint Premature or late functioning of fuze Potential injury to personel and equipment
detonating (PD)
PHL-14
Howitzer Ammunition- Propellant charge Fails to ignite properly Resulting in a cook off which could cause a blowback potential
injury/loss of life to personnel and damaged equuipment
PHL-15
Howitzer Ammunition- Propellant charge ignites prematurly due to cannon tube temp. Resulting in a cook off which could cause a blowback potential
injury/loss of life to personnel and damaged equuipment
PHL-16
Howitzer radio comunnication system Loss communication during fire mission failure to receive emergency voice commands
PHL-17
Howitzer fire extinguisher ineffective while the engine is running and doesn’t Loss of personnel and equipment due to fire
work above 1100 rpm
PHL-18
Howitzer computer computer dispays incorrect data or unreadable data Could result in round landing off target resulting in loss of personnel
and equipment
PHL-19
Howitzer computer computer display is unreadable Will result in mission failure due to digital communications
PHL-20
System Element Type:
Hazardous Operations
No. System Item
Hazard Hazard Effects
Howitzer Preperation for firing-breech Opening and closing of breech 1. Injury to personnel 2. possible Blowback when projectile is fired
PHL-21
Howitzer preperation for firing- checking recuperator proper fluid levels 1. Over filling with hydrolic fluid could result in blown seals during
recuperator firing resulting in round falling short of the target.
PHL-22
Howitzer preperation for firing-Collamator Improper Emplacement of the collamator, the can cause rounds to be fired in wrong direction.
primary aiming refrence..
PHL-23
Howitzer Ammunition failure to inspect ammunition Could result in unnecessary ammunition malfunctions, which could
cause bodily injury
PHL-24
Howitzer firing-direction Improper lay for direction Will result in round impacting left or right of the target causing
possible loss of life
PHL-25
Howitzer firing-elevation Improper lay for elevation will result in round impacting long or short of the target causing
possible loss of life to forward observers
PHL-26
Howitzer firing-fuze Wrong fuze settings Will result in round exploding premature or late which could cause
injury or loss of life to personnel
PHL-27
Howitzer firing-breech failure to ensure breech is properly closed Could result in a blowback, posible injury to personel or loss of life
PHL-28
Howitzer firing-firing Mechinsm Improper functioning or forcing to close Could result in permature funtioning of primer causing blowback
resulting in injury and loss of life
PHL-29
Howitzer Hull-Thermometer Self-indicating Thermometer fails 1. Long term exposure to extreme temperatures can produce central
neverous system damage and possible death.
PHL-30
System Element Type:
Hazardous Components
No. System Item
Hazard Hazard Effects
Howitzer canon visible damage or foreign matter in tube. 1. Severed injury or death of personnel. 2. round explodes in tube
PHL-31
Howitzer Track Lost or defective track(s) 1. Cause a rollover, placing occupants at risk of injury or death.
PHL-32
Howitzer Hull- Ventilation Ventilation air intake grille fails 1. Improper ventilation can cause suffocation, upper respirator
issues, or death to occupants due to prolonged exposure to toxic
fumes.
PHL-33
Howitzer Hull-Thermometer Self-indicating Thermometer fails 1. Long term exposure to extreme temperatures can produce central
neverous system damage and possible death.
PHL-34
Howitzer Hull- Lighting Incandescent lighting (dome and instrument panel) 1. Prolonged exposure can cause health issues such as headaches
emit ultraviolet radiation. and eye strain.
PHL-35
Howitzer Firing- Site Sighting instruments - telescopes 1. The telescopes alinement device is radioactively illuminated. 2. If
Valves are broken or defective can cause harm or death from
radiation exposure.
PHL-36
Howitzer personal heater Improperly operating personal heater 1. Improperly operating personal heater can lead to exhaust odors
or exposure to carbon monoxide. Carbon monoxide exposure can
cause headaches, difficulty breathing or death.
PHL-37
Howitzer exhaust grille Blocked exhaust grille can lead to CO poisoning. 1. A blocked exhaust grille will prevent air circulation within the hull
can lead to CO poisoning. (CO poisoning caused headaches,
dizziness, paranoid state or death)
PHL-38
Howitzer generator Exposure to high voltage. 1. High voltage can cause heart fibrillation, electrocution or death.
PHL-39
Howitzer rectifer Exposure to high voltage. 1. High voltage can cause heart fibrillation, electrocution or death.
PHL-40
System Element Type:
Hazardous Materials
No. System Item
Hazard Hazard Effects
Howitzer fire control alignment Personnel Exposed to trithium gas while using the 1. Personnel Health hazards depending on exposure time and
M140 Alignment device caused by broken valves. amount. 2. failure of the device to illuminate
PHL-41
Howitzer ammunition- unused propellant Propellant charge disposal requires burning of 1. can lead to damage to enviorment burns to personnel and
charges charges equipment.
PHL-42
Howitzer lubricant- Cleaner lubricant continus use of CLP may cause irritation of the upper respiratory tract and may be fatal if
preservetant (CLP) swallowed
PHL-43
Howitzer movement- Fuel Diesel Fuel spill 1. while refueling could cause injury to eyes, skin, lungs and is an
enviornmental hazard
PHL-44
Howitzer Hydraulics Hydraulic fluid spill 1. May cause swellingand redness to the skin. Can cause intestinal
problems which could ultimately lead to death and presents an
enviormental Hazard
PHL-45
Howitzer ammunition- white phosphorus White phosphorus exposure to personnel 1. Can cause injury or death by burning deep into tissue, being
round inhaled as a smoke and ingested and can lead to death.
PHL-46
Howitzer ammunition- subblamentary contains Tetrytol (secondary high explosive) Exposure 1. Can lead to skin sensitization, such as dermatitis, itch and
charge exposure to personnel erythema. It can also affect mucous membrane, respiratory tract
and possibly the liver.
PHL-47
Howitzer engine Engine transmission oil spillage 1. Ground water pollution can happen from spillage, seeping into
the ground.
PHL-48
Howitzer radiator Radiator coolant (Anti-freeze) spillage 1. Anti-freeze is poisnous to humans and other animals. If ingested
can lead to severe diarrhea, vomiting, kidney falure and death.
PHL-49
Howitzer engine Engine oil spillage (pollution) 1. Engine oil contains a mixture of of toxic compounds such as
benzene. Benzene is known to cause leukemia in humans.
PHL-50
annon Battery & M119 Cannon
Energy Sources
Comments
1. Ensure personnel are clear of recoil before firing 2. Ensure proper fluid levels in recuperator,
no obstruction are in recoil area.
1. Ensure primer is stored in dry place and do not remove from plastic package until ready for use
1. Must be stored in cool dry place, inspect before use 2. ensure correct charge is loeded using secondary checks
1. Stand at a safe distance from vehicle when starting do not operate in confined space for example a dough in
position.
1. Ensure to check fuel line and pump for leaks
Comments
1. Conduct dry missions prior to live fire.
1. swab cannon tube with water to keep tempature down during intence firing
Comments
Ensure breech is properly closed witness marks completely alligned.
Ensure fluid levels are correct and there are no cracks around seals.
1. Ensure aiming refrence is emplaced IAW TM 9-2350-311-10 2. Ensure secondary check are being
conducted.
1. Ensure correct target data is being placed on the gunners site by the gunner use secondary safety checks
conducted by the section chief (SC)
1. Ensure correct target data is being placed on the assistant gunners site by the AG use secondary safety checks
conducted by the section chief
1. Proper safety checks conducted by cannoneer #1 announced to the section chief, section chief properly verifies
settings proir to loading
1. Ensure proper maintenance is conducted to keep equipment in proper working condiction IAW TM 9-2350-311-
10
Comments
1. Muzzle plug is most common, ensure tube is clear of obstructions before loading
1. Check track for safety before driving IAW TM 9-2350-311-10
1. Ensure proper maintenance is conducted to keep equipment in proper working condiction IAW TM 9-2350-311-
10
1. Ensure proper maintenance is conducted to keep equipment in proper working condiction IAW TM 9-2350-311-
10
1. ensure proper PPE is being used while operating equipment 2. ensure device is properly stored in
carring case and case is secured
1. Ensure proper maintenance is conducted to keep equipment in proper working condiction IAW TM 9-2350-311-
10
Comments
1. ensure proper PPE is being used while operating equipment 2. ensure device is properly stored in
carring case and case is secured
1. use PPE while refueling including the use of drip pan 2. Any spillage be reported to
enviromental safety office
1. use PPE while adding fluid including the use of drip pan 2. Any spillage be reported to
enviromental safety office
1. properly secure and unused charge until they can be turned in for proper disposal
1. use PPE while adding fluid including the use of drip pan 2. Any spillage be reported to
enviromental safety office
1. use PPE while adding fluid including the use of drip pan 2. Any spillage be reported to
enviromental safety office
1. use PPE while adding fluid including the use of drip pan 2. Any spillage be reported to
enviromental safety office
PHA Analysis
Sytem Element Type: M109 Howitzers Fire Control System: Energy Sources
Element Subsystem-Feed Analyst:
Number Hazard Causes
Howitzer veiable Recoil Variable Recoil system striking
personnel
PHA-1
PHA-3
PHA-5
PHA-9
PHA-10
PHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Functions
Element Subsystem-Feed Analyst:
Number Hazard Causes
PHA-11 Howitzer gunner display unit(GDU) GDU fails to display correct data
Premature or late funtioning of fuze
PHA-12 Howitzer Ammunition- Fuze verable time (VT) up to 1 sec
PHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Operation
Element Subsystem-Feed Analyst:
Number Hazard Causes
PHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Material
Element Subsystem-Feed Analyst:
Number Hazard Causes
PHA-33 Howitzer lubricant- Cleaner lubricant preservetant (CLP) continus use of CLP
PHA Analysis
System Element Type: M109 Howitzers Fire Control System: Harzadous Components
Element Subsystem-Feed Analyst:
Number Hazard Causes
Date:
Effects Mode IMRI Recommended Actions FMRI Comments Status
Crew will not receive data to conduct poor 1. Conduct dry missions prior 2E
2E ope n
mission maintanance to live fire.
Round could detonate as close as 300 1. ensure correct time is set, 2E
meters from tube potential enjury to operational 2E ope n
setting verified by SC
personnel and equipment
Date:
Effects Mode IMRI Recommended Actions FMRI Comments Status
1. Over filling with hydrolic fluid could Ensure fluid levels are correct
result in blown seals during firing operational 2E and there are no cracks 2E ope n
resulting in round falling short of the
around seals.
target.
1. Ensure proper
1. Long term exposure to extreme maintenance is conducted to
temperatures can produce central
neverous system damage and possible operational 1E keep equipment in proper 1E ope n
working condiction IAW TM
death. 9-2350-311-10
Date:
Effects Mode IMRI Recommended Actions FMRI Comments Status
Date:
Effects Mode IMRI Recommended Actions FMRI Comments Status
1. Ensure proper
1. Improper ventilation can cause maintenance is conducted to
suffocation, upper respirator issues, or operational 2E keep equipment in proper 2E ope n
death to occupants due to prolonged
working condiction IAW TM
exposure to toxic fumes. 9-2350-311-10
1. Ensure proper
1. Long term exposure to extreme maintenance is conducted to
temperatures can produce central
neverous system damage and possible operational 2E keep equipment in proper 2E ope n
working condiction IAW TM
death. 9-2350-311-10
TLM SCF
Type Yes/No
TLM SCF
Type Yes/No
TLM SCF
Type Yes/No
TLM SCF
Type Yes/No
SSHA Analysis
Sytem Element Type: M109 Howitzers Fire Control System: Energy Sources
Element Subsystem-Feed Analyst:
Date:
SSHA-5 Operational
Howitzer Fuel fuel leaks into could cause fire
the hul of resulting in loss of
howitzer equipment, injury to
personnel or loss of life
SSHA-6 Operational
SSHA-7 Operational
SSHA-8 Operational
SSHA-9 Operational
SSHA-10 Operational
SSHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Functions
ineffective
while the
engine is
Howitzer fire running and Loss of personnel and
SSHA-18 Operational 2E
extinguisher doesn’t work equipment due to fire
above 1100
rpm
SSHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Operation
Improper
Emplacement
Howitzer of the
preperation can cause rounds to be Operational
SSHA-23 collamator, 2E
for firing- fired in wrong direction.
the primary
Collamator aiming
refrence..
Could result in
unnecessary
failure to
Howitzer ammunition
SSHA-24 inspect Operational 2E
Ammunition malfunctions, which
ammunition
could cause bodily
injury
Could result in
Improper
Howitzer permature funtioning of
functioning or
SSHA-29 firing-firing primer causing Operational 1E
forcing to
Mechinsm blowback resulting in
close injury and loss of life
SSHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Material
Personnel
Exposed to 1. Personnel Health
trithium gas hazards depending on
Howitzer fire while using exposure time and
SSHA-31 control the M140 Operational 2E
amount.
alignment Alignment 2. failure of the
device caused device to illuminate
by broken
valves.
Propellant
Howitzer charge 1. can lead to damage
ammunition- disposal to enviorment burns to Operational
SSHA-32 unused 2E
requires personnel and
propellant burning of equipment.
charges charges
Howitzer
lubricant- may cause irritation of
Cleaner continus use the upper respiratory Operational
SSHA-33 2E
lubricant of CLP tract and may be fatal if
preservetant swallowed
(CLP)
1. May cause
swellingand redness to
the skin. Can cause
Howitzer Hydraulic fluid intestinal problems
SSHA-35 which could ultimately Operational 1E
Hydraulics spill
lead to death and
presents an
enviormental Hazard
1. Anti-freeze is
poisnous to humans
Radiator and other animals. If
Howitzer coolant (Anti-
SSHA-39 ingested can lead to Operational 1E
radiator freeze) severe diarrhea,
spillage vomiting, kidney falure
and death.
SSHA Analysis
System Element Type: M109 Howitzers Fire Control System: Harzadous Components
Incandescent
lighting (dome 1. Prolonged exposure
Howitzer Hull- and can cause health issues Operational
SSHA-45 instrument 1E
Lighting such as headaches and
panel) emit eye strain.
ultraviolet
radiation.
1. The telescopes
alinement device is
radioactively
Sighting
Howitzer instruments - illuminated. 2. If Valves
SSHA-46 are broken or defective Operational 2E
Firing- Site telescopes can cause harm or
death from radiation
exposure.
1. Improperly
operating personal
heater can lead to
Improperly exhaust odors or
Howitzer operating exposure to carbon
SSHA-47 personal Operational 2E
personal monoxide. Carbon
heater heater monoxide exposure can
cause headaches,
difficulty breathing or
death.
1. A blocked exhaust
grille will prevent air
circulation within the
Blocked
exhaust grille hull can lead to CO
Howitzer
SSHA-48 exhaust grille can lead to CO poisoning. (CO Operational 2E
poisoning caused
poisoning. headaches, dizziness,
paranoid state or
death)
ope n
ope n
ope n
ope n
1. Ensure to check fuel line and
pump for leaks
ope n
ope n
ope n
ope n
1. Improved communications
between Howitzer crew and fire
direction center
ope n
TLM SCF
TLM SCF
TLM SCF
TLM SCF
SHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Functions
Element Subsystem-Feed Analyst: Date:
Round could
Howitzer Premature or detonate as close as
Ammunition- late funtioning 300 meters from
SHA-12 Firing Function Operational 2E
Fuze verable of fuze up to 1 tube potential
time (VT) sec enjury to personnel
and equipment
Resulting in a cook
off which could
Howitzer
Fails to ignite cause a blowback
Ammunition-
SHA-15 Firing Function potential injury/loss Operational 1E
Propellant properly
charge of life to personnel
and damaged
equuipment
Resulting in a cook
off which could
Howitzer ignites cause a blowback
Ammunition- prematurly
SHA-16 Firing Function potential injury/loss Operational 2E
Propellant due to cannon of life to personnel
charge tube temp. and damaged
equuipment
Loss
Howitzer radio communicatio failure to receive
SHA-17 Comunication function comunnication n during fire emergency voice Operational 2E
system commands
mission
ineffective
while the
engine is Loss of personnel
Howitzer fire
SHA-18 Firing Function running and and equipment due Operational 2E
extinguisher doesn’t work to fire
above 1100
rpm
Will result in
computer
Howitzer mission failure due Operational
SHA-20 Programming function display is 1E
computer to digital
unreadable communications
SHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Operation
Element Subsystem-Feed Analyst: Date:
1. Injury to
Howitzer Opening and personnel 2.
SHA-21 Programming function Preperation for closing of possible Blowback Operational 2E
firing-breech breech when projectile is
fired
Improper
Emplacement
Howitzer of the can cause rounds to
preperation for
SHA-23 Programming function collamator, be fired in wrong Operational 2E
firing- the primary direction.
Collamator aiming
refrence..
Could result in
unnecessary
failure to
Howitzer ammunition
SHA-24 Programming function inspect malfunctions, which Operational 2E
Ammunition ammunition
could cause bodily
injury
Will result in round
impacting left or
Howitzer firing- Improper lay
SHA-25 Programming function right of the target Operational 1E
direction for direction causing possible
loss of life
Could result in
Improper permature
Howitzer firing- functioning or funtioning of primer Operational
SHA-29 Programming function 1E
firing Mechinsm forcing to causing blowback
close resulting in injury
and loss of life
1. Long term
exposure to
Self-indicating extreme
Howitzer Hull- Thermometer temperatures can
SHA-30 Programming function Operational 1E
Thermometer produce central
fails neverous system
damage and
possible death.
SHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Material
Element Subsystem-Feed Analyst: Date:
Propellant
Howitzer 1. can lead to
charge
ammunition- damage to
disposal
SHA-32 Programming function unused enviorment burns Operational 2E
requires
propellant to personnel and
burning of
charges equipment.
charges
Howitzer
lubricant- may cause irritation
of the upper
Cleaner continus use
SHA-33 Programming function respiratory tract and Operational 2E
lubricant of CLP may be fatal if
preservetant
swallowed
(CLP)
1. while refueling
could cause injury
Howitzer Diesel Fuel to eyes, skin, lungs Operational
SHA-34 Programming function movement- 2E
spill and is an
Fuel enviornmental
hazard
1. May cause
swellingand redness
to the skin. Can
cause intestinal
Howitzer Hydraulic fluid problems which
SHA-35 Programming function Operational 1E
Hydraulics spill could ultimately
lead to death and
presents an
enviormental
Hazard
1. Ground water
Engine pollution can
Howitzer
SHA-38 Power function transmission happen from Operational 2E
engine oil spillage spillage, seeping
into the ground.
1. Anti-freeze is
poisnous to humans
Radiator and other animals.
Howitzer coolant (Anti-
SHA-39 Power function If ingested can lead Operational 1E
radiator freeze) to severe diarrhea,
spillage vomiting, kidney
falure and death.
1. Engine oil
contains a mixture
of of toxic
Engine oil
Howitzer compounds such as Lack of
SHA-40 spillage 1E
engine benzene. Benzene monitoring
(pollution) is known to cause
leukemia in
humans.
SHA Analysis
System Element Type: M109 Howitzers Fire Control System: Harzadous Components
Element Subsystem-Feed Analyst: Date:
1. Cause a rollover,
Lost or placing occupants at Operational
SHA-42 Power function Howitzer Track defective 2E
risk of injury or
track(s) death.
1. Improper
ventilation can
Ventilation air cause suffocation,
Howitzer Hull- upper respirator
SHA-43 Power function intake grille issues, or death to Operational 2E
Ventilation fails
occupants due to
prolonged exposure
to toxic fumes.
1. Long term
exposure to
extreme
Self-indicating temperatures can
Howitzer Hull-
SHA-44 Power function Thermometer produce central Operational 2E
Thermometer fails neverous system
damage and
possible death.
Incandescent
lighting (dome 1. Prolonged
and exposure can cause
Howitzer Hull-
SHA-45 Power function instrument health issues such Operational 1E
Lighting panel) emit as headaches and
ultraviolet eye strain.
radiation.
1. The telescopes
alinement device is
radioactively
Sighting
Howitzer Firing- illuminated. 2. If
SHA-46 Power function instruments - Valves are broken or Operational 2E
Site telescopes defective can cause
harm or death from
radiation exposure.
1. Improperly
operating personal
heater can lead to
exhaust odors or
Improperly exposure to carbon
Howitzer operating
SHA-47 Power function monoxide. Carbon Operational 2E
personal heater personal monoxide exposure
heater can cause
headaches,
difficulty breathing
or death.
1. A blocked
exhaust grille will
prevent air
Blocked circulation within
Howitzer exhaust grille the hull can lead to Operational
SHA-48 Power function 2E
exhaust grille can lead to CO CO poisoning. (CO
poisoning. poisoning caused
headaches,
dizziness, paranoid
state or death)
1. Ensure projectiles
are properly secured
with lock pins
ope n
1. Ensure primer is
stored in dry place and
do not remove from
plastic package until
ready for use ope n
1. Must be stored in
cool dry place, inspect
before use 2. ensure
correct charge is
loeded using secondary
checks ope n
1. Stand at a safe
distance from vehicle
when starting do not
operate in confined
space for example a
dough in position. ope n
ope n
1. conduct periodic
commo checks
ope n
ope n
Do not have open
flames around the
battery or make sparks
1. Ensure proper
connection 2. use
proper PPE while ope n
handling antena
1. Improved
communications
between Howitzer
crew and fire direction ope n
center
TLM SCF
1. Conduct dry
missions prior to live 2E ope n
fire.
1. ensure Propellant
charges are properly 1E ope n
stored prior to loading
1. ensure regular
maintenance is 1E ope n
conducted
1. Ensure equipment is
fully mission capable 1E ope n
prior to mission
TLM SCF
Ensure breech is
properly closed witness 2E ope n
marks completely
alligned.
1. Ensure aiming
refrence is emplaced
IAW TM 9-2350-311-10
2E ope n
2. Ensure
secondary check are
being conducted.
1. Ensure inspection
are done IAW TM 9- 2E ope n
2350-311-10
1. Ensure correct target
data is being placed on
the gunners site by the
gunner use secondary 1E ope n
safety checks
conducted by the
section chief (SC)
1. Ensure witness
marks are alligned and 2E ope n
cheched by SC
1. Check proper
functioning of device 1E ope n
during prefire checks
1. Ensure proper
maintenance is
conducted to keep
equipment in proper 1E ope n
working condiction
IAW TM 9-2350-311-10
TLM SCF
2.
ensure fire fight
equipment is on hand
TLM SCF
1. Ensure proper
maintenance is
conducted to keep
equipment in proper 2E ope n
working condiction
IAW TM 9-2350-311-10
1. Ensure proper
maintenance is
conducted to keep
equipment in proper 2E ope n
working condiction
IAW TM 9-2350-311-10
1. ensure grille is free
of obstructions before 2E ope n
and during operations
O&SHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous
Functions
Element Subsystem-Feed Analyst: Date:
Recommende
Number Hazard Causes Effects Mode IMRI d Actions
Use the computer to execu
Howitzer Crew will not 1. Conduct
GDU fails to
gunner receive data Operational dry missions
O&SHA-11 display 2E
display to conduct prior to live
correct data
unit(GDU) mission fire.
Round could
detonate as
close as 300
Premature or
Howitzer meters from 1. ensure
late
Ammunition- funtioning of tube correct time
O&SHA-12 Operational 2E
Fuze verable fuze up to 1 potential is set, setting
time (VT) enjury to verified by SC
sec personnel
and
equipment
Resulting in a
cook off
which could 1. ensure
cause a
Howitzer Propellant
Ammunition- Fails to ignite blowback charges are
O&SHA-15 potential Operational 1E
Propellant properly properly
injury/loss of
charge stored prior
life to to loading
personnel
and damaged
equuipment
Resulting in a
cook off
which could 1. swab
ignites cause a cannon tube
Howitzer
Ammunition- prematurly blowback with water to
O&SHA-16 due to potential Operational 2E keep
Propellant cannon tube injury/loss of tempature
charge temp. life to down during
personnel intence firing
and damaged
equuipment
Power and communicate ov
failure to
Howitzer Loss 1. conduct
receive
radio communicati periodic
O&SHA-17 emergency Operational 2E
comunnicatio on during fire commo
voice
n system mission commands checks
O&SHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous
Operation
Element Subsystem-Feed Analyst: Date:
Recommende
Number Hazard Causes Effects Mode IMRI d Actions
Closing the breech with
witness marks completely Ensure
alligned. 1. Injury to breech is
personnel 2.
Howitzer properly
Opening and possible
Preperation closed
O&SHA-21 closing of Blowback Operational 2E
for firing- witness
breech when
breech marks
projectile is completely
fired alligned.
1. Over filling
with hydrolic
fluid could Ensure fluid
Howitzer checking result in levels are
preperation recuperator blown seals Operational correct and
O&SHA-22 2E
for firing- proper fluid during firing there are no
recuperator levels resulting in cracks around
round falling seals.
short of the
target.
Establishing the aiming re
1. Ensure
aiming
refrence is
Improper emplaced
Emplacement
Howitzer can cause IAW TM 9-
of the
preperation rounds to be Operational 2350-311-10
O&SHA-23 collamator, 2E
for firing- fired in wrong 2.
the primary
Collamator direction. Ensure
aiming secondary
refrence..
check are
being
conducted.
Could result
in 1. Ensure
unnecessary
failure to inspection
Howitzer ammunition
O&SHA-24 Ammunition inspect malfunctions, Operational 2E are done IAW
ammunition which could TM 9-2350-
311-10
cause bodily
injury
1. Ensure
correct target
Will result in data is being
round placed on the
impacting left gunners site
Howitzer Improper lay or right of the Operational by the
O&SHA-25 firing- 1E
for direction target gunner use
direction causing secondary
possible loss safety checks
of life conducted by
the section
chief (SC)
1. Ensure
will result in correct target
round data is being
impacting placed on the
long or short assistant
Howitzer
Improper lay of the target Operational gunners site
O&SHA-26 firing- 2E
for elevation causing by the AG use
elevation possible loss secondary
of life to safety checks
forward conducted by
observers the section
chief
Operating the annon
1. Proper
Will result in safety checks
round conducted by
exploding cannoneer #1
premature or announced to
Howitzer Wrong fuze
O&SHA-27 late which Operational 2E the section
firing-fuze settings
could cause chief, section
injury or loss chief properly
of life to verifies
personnel settings proir
to loading
Could result
in permature 1. Check
funtioning of
Improper proper
Howitzer primer
O&SHA-29 firing-firing functioning causing Operational 1E functioning
or forcing to blowback of device
Mechinsm close during prefire
resulting in checks
injury and
loss of life
O&SHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous
Material
Element Subsystem-Feed Analyst: Date:
Recommende
Number Hazard Causes Effects Mode IMRI d Actions
Align the PPE
1. ensure
proper PPE is
1. Personnel
Personnel being used
Health
Exposed to while
trithium gas hazards operating
depending on
Howitzer fire while using equipment
exposure
the M140
O&SHA-31 control time and Operational 2E
Alignment 2. ensure
alignment amount.
device device is
caused by properly
2. failure of
broken stored in
the device to
valves. carring case
illuminate and case is
secured
Chemical substance
may cause
Howitzer irritation of
lubricant-
the upper 1. Use PPE
Cleaner continus use
O&SHA-33 respiratory Operational 2E while using
lubricant of CLP tract and may product
preservetant be fatal if
(CLP) swallowed
1. use PPE
while
1. while refueling
refueling including the
could cause use of drip
Howitzer injury to
Diesel Fuel pan
O&SHA-34 movement- eyes, skin, Operational 2E
spill
Fuel lungs and is 2. Any
an spillage be
enviornment reported to
al hazard
enviromental
safety office
Chemical substance
1. May cause
swellingand 1. use PPE
redness to while adding
the skin. Can fluid
cause including the
intestinal use of drip
Howitzer Hydraulic problems pan
O&SHA-35 which could Operational 1E
Hydraulics fluid spill
ultimately 2. Any
lead to death spillage be
and presents reported to
an enviromental
enviormental safety office
Hazard
1. use PPE
1. Can cause while
injury or handling
death by
Howitzer round
White burning deep
ammunition- phosphorus into tissue,
O&SHA-36 white being inhaled Operational 2E
exposure to
phosphorus 2. Any
personnel as a smoke
round spillage be
and ingested reported to
and can lead
to death. enviromental
safety office
1. Can lead to
skin
sensitization,
such as
contains 1. properly
dermatitis,
Tetrytol secure and
itch and
Howitzer (secondary unused
erythema. It
ammunition- high charge until
O&SHA-37 can also Operational 2E
subblamentar explosive) they can be
affect
y charge Exposure turned in for
mucous
exposure to proper
membrane,
personnel disposal
respiratory
tract and
possibly the
liver.
1. use PPE
while adding
fluid
1. Ground
including the
water use of drip
Engine pollution can
Howitzer pan
O&SHA-38 transmission happen from Operational 2E
engine oil spillage spillage,
2. Any
seeping into spillage be
the ground. reported to
enviromental
safety office
adding fluid including the
O&SHA Analysis
System Element Type: M109 Howitzers Fire Control System: Harzadous
Components
Element Subsystem-Feed Analyst: Date:
Recommende
Number Hazard Causes Effects Mode IMRI d Actions
Operate the howitzer can
1. Muzzle
1. Severed plug is most
visible injury or common,
damage or death of
O&SHA-41 Howitzer ensure tube
foreign personnel. Operational 2E
canon is clear of
matter in 2. round obstructions
tube. explodes in before
tube loading
1. Improper
ventilation 1. Ensure
can cause proper
suffocation, maintenance
upper is conducted
Howitzer Ventilation respirator to keep
O&SHA-43 Hull- air intake issues, or Operational 2E equipment in
Ventilation grille fails death to proper
occupants working
due to condiction
prolonged IAW TM 9-
exposure to 2350-311-10
toxic fumes.
Incandescent 1. Prolonged
lighting exposure can 1. Only use
(dome and cause health
O&SHA-45 Howitzer when needed
Hull- Lighting instrument issues such as Operational 1E for operating
panel) emit headaches equipment
ultraviolet and eye
radiation. strain.
1. ensure
1. The proper PPE is
telescopes being used
alinement while
device is operating
radioactively equipment
Sighting illuminated.
O&SHA-46 Howitzer instruments - 2. If Valves Operational 2E
Firing- Site 2. ensure
telescopes are broken or device is
defective can properly
cause harm stored in
or death from carring case
radiation and case is
exposure. secured
Use the heaters properly
1.
Improperly
operating
personal
heater can 1. Ensure
lead to proper
exhaust maintenance
odors or is conducted
Improperly
Howitzer exposure to to keep
operating
O&SHA-47 personal carbon Operational 2E equipment in
personal
heater monoxide. proper
heater Carbon working
monoxide condiction
exposure can IAW TM 9-
cause 2350-311-10
headaches,
difficulty
breathing or
death.
1. A blocked
exhaust grille
will prevent
air circulation
within the 1. ensure
hull can lead grille is free
Blocked to CO of
Howitzer exhaust grille poisoning.
O&SHA-48 exhaust grille can lead to (CO Operational 2E obstructions
before and
CO poisoning. poisoning during
caused operations
headaches,
dizziness,
paranoid
state or
death)
ope n
ope n
ope n
ope n
ope n
ope n
ope n
ope n
ope n
ope n
TLM SCF
FMRI Comments Status Type Yes/No
2E ope n
2E ope n
2E ope n
2E ope n
1E ope n
2E ope n
2E ope n
2E ope n
1E ope n
1E ope n
TLM SCF
2E ope n
2E ope n
2E ope n
2E ope n
1E ope n
2E ope n
2E ope n
2E ope n
1E ope n
1E ope n
TLM SCF
2E ope n
2E ope n
2E ope n
1E ope n
2E ope n
2E ope n
2E ope n
1E ope n
1E ope n
TLM SCF
2E ope n
2E ope n
2E ope n
2E ope n
1E ope n
2E ope n
2E ope n
2E ope n
1E ope n
1E ope n
HHA Analysis
Sytem Element Type: M109
Element Subsystem-Feed Howitzers Fire Control System: Energy Sources
Analyst:
Date:
HH Type Number Hazard Causes Effects Mode IMRI
Howitzer Variable Recoil 1. Injury to
veiable Recoil system striking personnel/pos
personnel ible loss of life
HHA-1 Operational
Explosion
Cab Rounds falling 1. Injury to
Amminition out of racks personnel/pos
HHA-2 safety racks ible loss of life Operational
Explosion
Howitzer M82 primer 1. Howitzer
Ammunition failure to fails to fire
function resulting in at
least a five
minute delay
and cusing
HHA-3 explosion risk Operational
Explosion
Howitzer M4 Series 1Howitzer fails
Ammunition Propelling to fire
Charges failure resulting in
to function 5mi delay 2.
Round falls
long or short
of target
3. possible
HHA-4 injury/loss of Operational
life to
personnel
Explosion
Howitzer The engine 1. can cause
Engine produces illness,
carbon permanent
monoxcide neurological
HHA-5 damage, loss Operational
of life
Oxygen defficiency
Howitzer Fuel fuel leaks into could cause
the hul of fire resulting
howitzer in loss of
equipment,
injury to
personnel or
HHA-6 loss of life Operational
Ogygen diffficiency
Howitzer radio Loss failure to
comunnication communicatio receive
system n during fire emergency
HHA-7 mission voice Operational
commands
Noise
Howitzer led acid Gases can
Battery battery gases explode,
can explode causing injury,
loss of life and
damage or
HHA-8 loss of Operational
equipment
Fire
Howitzer Improper will result in
computer installation low level
HHA-9 shock to Operational
personnel
Electric shock
Howitzer computer Could result in
computer displays ghost round fired
data inadvertently
HHA-10 Operational
Explosion
HHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous
Functions
Element Subsystem-Feed Analyst: Date:
Number Hazard Causes Effects Mode IMRI
Fire
Round could
detonate as
Howitzer Premature or close as 300
Ammunition- late funtioning meters from Operational
HHA-12 2E
Fuze verable of fuze up to 1 tube potential
time (VT) sec enjury to
personnel and
equipment
Fire
Fire
Resulting in a
cook off which
could cause a
Howitzer ignites blowback
Ammunition- prematurly potential
HHA-16 due to cannon injury/loss of Operational 2E
Propellant
charge tube temp. life to
personnel and
damaged
equuipment
Fire
failure to
Howitzer radio Loss receive
HHA-17 comunnication communicatio emergency Operational 2E
n during fire
system voice
mission commands
Noise
ineffective
while the
Loss of
engine is
Howitzer fire personnel and Operational
HHA-18 running and 2E
extinguisher equipment
doesn’t work due to fire
above 1100
rpm
Fire
Could result in
computer round landing
dispays off target
Howitzer
HHA-19 incorrect data resulting in Operational 1E
computer or unreadable loss of
data personnel and
equipment
Fire
Will result in
computer mission failure
Howitzer
HHA-20 display is due to digital Operational 1E
computer
unreadable communicatio
ns
Fire
HHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous
Operation
Element Subsystem-Feed Analyst: Date:
Number Hazard Causes Effects Mode IMRI
1. Injury to
personnel 2.
Howitzer Opening and possible
Preperation
HHA-21 closing of Blowback Operational 2E
for firing- breech when
breech projectile is
fired
Fire
1. Over filling
with hydrolic
fluid could
Howitzer checking result in blown
preperation recuperator
HHA-22 seals during Operational 2E
for firing- proper fluid firing resulting
recuperator levels in round
falling short of
the target.
Fire
Could result in
unnecessary
failure to ammunition
Howitzer
HHA-24 inspect malfunctions, Operational 2E
Ammunition ammunition which could
cause bodily
injury
Fire
Will result in
round
impacting left
Howitzer Improper lay
HHA-25 or right of the Operational 1E
firing-direction for direction target causing
possible loss
of life
Fire
will result in
round
impacting long
Howitzer or short of the
Improper lay
HHA-26 firing- target causing Operational 2E
for elevation
elevation possible loss
of life to
forward
observers
Fire
Will result in
round
exploding
premature or
Howitzer Wrong fuze
HHA-27 late which Operational 2E
firing-fuze settings could cause
injury or loss
of life to
personnel
Could result in
failure to a blowback,
Howitzer ensure breech
HHA-28 posible injury Operational 2E
firing-breech is properly to personel or
closed loss of life
Fire
Could result in
permature
Improper funtioning of
Howitzer
HHA-29 firing-firing functioning or primer causing Operational 1E
forcing to blowback
Mechinsm close resulting in
injury and loss
of life
Fire
1. Long term
exposure to
extreme
temperatures
Howitzer Hull- Self-indicating can produce
HHA-30 Thermometer central Operational 1E
Thermometer fails neverous
system
damage and
possible
death.
Poinous gas
HHA Analysis
System Element Type: M109 Howitzers Fire Control System: Hazardous Material
Element Subsystem-Feed Analyst: Date:
Number Hazard Causes Effects Mode IMRI
Personnel 1. Personnel
Exposed to Health hazards
trithium gas depending on
Howitzer fire while using exposure time
HHA-31 control the M140 and amount. Operational 2E
alignment Alignment
device caused 2. failure of
by broken the device to
valves. illuminate
Poisonous substance
Propellant 1. can lead to
Howitzer charge damage to
ammunition- disposal enviorment
HHA-32 unused Operational 2E
requires burns to
propellant burning of personnel and
charges charges equipment.
Fire
may cause
Howitzer
irritation of
lubricant- the upper
Cleaner continus use
HHA-33 respiratory Operational 2E
lubricant of CLP tract and may
preservetant be fatal if
(CLP)
swallowed
Posinous substance
1. while
refueling could
Howitzer cause injury to
Diesel Fuel
HHA-34 movement- eyes, skin, Operational 2E
spill
Fuel lungs and is an
enviornmental
hazard
Chemical substance
1. May cause
swellingand
redness to the
skin. Can
cause
Howitzer Hydraulic fluid intestinal
HHA-35 problems Operational 1E
Hydraulics spill which could
ultimately lead
to death and
presents an
enviormental
Hazard
1. Can cause
injury or death
by burning
Howitzer White deep into
ammunition- phosphorus tissue, being Operational
HHA-36 white 2E
exposure to inhaled as a
phosphorus personnel smoke and
round ingested and
can lead to
death.
Chemical substance
1. Can lead to
skin
sensitization,
such as
contains dermatitis,
Tetrytol
Howitzer itch and
(secondary
ammunition- erythema. It
HHA-37 high explosive) can also affect Operational 2E
subblamentar Exposure
y charge mucous
exposure to membrane,
personnel respiratory
tract and
possibly the
liver.
Chemical substance
1. Ground
water
Engine pollution can
Howitzer
HHA-38 transmission happen from Operational 2E
engine oil spillage spillage,
seeping into
the ground.
Chemical substance
1. Anti-freeze
is poisnous to
humans and
other animals.
Radiator If ingested
Howitzer coolant (Anti- can
HHA-39 lead to Operational 1E
radiator freeze) severe
spillage diarrhea,
vomiting,
kidney falure
and death.
Chemical substance
1. Engine oil
contains a
mixture of of
toxic
compounds
Engine oil
Howitzer such as
HHA-40 spillage Operational 1E
engine benzene.
(pollution) Benzene is
known to
cause
leukemia in
humans.
Chemical substance
HHA Analysis
System Element Type: M109 Howitzers Fire Control System: Harzadous
Components
Element Subsystem-Feed Analyst: Date:
Number Hazard Causes Effects Mode IMRI
1. Severed
visible injury or death
Howitzer damage or of personnel. Operational
HHA-41 2E
canon foreign matter 2. round
in tube. explodes in
tube
Fire
1. Cause a
rollover,
Lost or placing
HHA-42 Howitzer Track defective Operational 2E
occupants at
track(s)
risk of injury
or death.
Fire
1. Improper
ventilation can
cause
suffocation,
upper
Ventilation air
Howitzer Hull- intake grille respirator
HHA-43 Operational 2E
Ventilation issues, or
fails death to
occupants due
to prolonged
exposure to
toxic fumes.
Oxygen deficiency
1. Long term
exposure to
extreme
temperatures
Self-indicating can produce
Howitzer Hull- Thermometer central
HHA-44 Operational 2E
Thermometer fails neverous
system
damage and
possible
death.
High temperature
Incandescent 1. Prolonged
lighting (dome exposure can
and
HHA-45 Howitzer Hull- instrument cause health Operational 1E
Lighting issues such as
panel) emit headaches
ultraviolet and eye strain.
radiation.
Light
1. The
telescopes
alinement
device is
radioactively
Sighting illuminated. 2.
Howitzer
HHA-46 instruments - If Valves are Operational 2E
Firing- Site telescopes broken or
defective can
cause harm or
death from
radiation
exposure.
Radioactive material
1. Improperly
operating
personal
heater can
lead to
exhaust odors
or exposure to
Improperly
Howitzer carbon
operating
HHA-47 personal monoxide. Operational 2E
personal
heater Carbon
heater monoxide
exposure can
cause
headaches,
difficulty
breathing or
death.
Temperature
1. A blocked
exhaust grille
will prevent air
circulation
within the hull
Blocked
exhaust grille can lead to CO
Howitzer
HHA-48 exhaust grille can lead to CO poisoning. Operational 2E
(CO poisoning
poisoning.
caused
headaches,
dizziness,
paranoid state
or death)
Oxygen deficiency
1. High
voltage can
Howitzer Exposure to cause heart
HHA-49 Operational 1E
generator high voltage. fibrillation,
electrocution
or death.
Electric shock
1. High
voltage can
Howitzer Exposure to cause heart
HHA-50 Operational 1E
rectifer high voltage. fibrillation,
electrocution
or death.
Electric shock
TLM SCF
Recommended Actions FMRI Comments Status Type Yes/No
1. Ensure personnel are clear of recoil
before firing 2. Ensure
proper fluid levels in recuperator, no
obstruction are in recoil area. ope n
ope n
ope n
ope n
ope n
ope n
ope n
TLM SCF
Recommended Actions FMRI Comments Status Type Yes/No
TLM SCF
Recommended Actions FMRI Comments Status Type Yes/No
Ensure breech is properly closed witness 2E ope n
marks completely alligned.
TLM SCF
Recommended Actions FMRI Comments Status Type Yes/No
TLM SCF
Recommended Actions FMRI Comments Status Type Yes/No
1. Muzzle plug is most common, ensure
tube is clear of obstructions before loading 2E ope n
Design Test
SSR System Safety Requirement HAR TLM Requirem Requirem
SC
Number (SSR) Number Number ent ent
Number Number
SSR-1 No single point failure Y 1 7
can result in missile
launch.
Test
Comments
Method Coverage Results
(T/A/I/N) (E/I) (P/F)