Version: V6.50.103
ZTE CORPORATION
No. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright © 2013 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.
Revision History
Intended Audience
l Telecommunication engineers
l Maintenance engineers
Chapter Summary
1-1
1-2
2-1
Steps
1. Select View > Status Management, see Figure 2-1. The Status Management tab
page is displayed.
2-2
2. Select Root Node > GERAN Subnetwork > Managed Network Element. The
Configuration Resource Tree is expanded, see Figure 2-2.
2-3
Prerequisite
The network management system (NMS) operates properly.
The network element is connected to the NMS properly.
Steps
1. On the toolbar, click . The LED status query dialog box is displayed.
2-4
Prerequisite
The network management system (NMS) operates properly.
The network element is connected to the NMS properly.
Steps
1. On the toolbar, click . The Memory Information Query dialog box is displayed.
2-5
3. Click OK.
– End of Steps –
1. On the tool bar of managed object tab, click . A confirmation dialog box is
displayed, see Figure 2-5
2. Click Yes.
– End of Steps –
2-6
3. Click OK.
– End of Steps –
Prerequisite
The network management system (NMS) operates properly.
The network element is connected to the NMS properly.
Steps
1. On the toolbar, click . The NTP time operation dialog box is displayed.
2. Select an option, see Figure 2-7.
2-7
Note:
The saving the status dialog box will be displayed before users close the status
management window.
– End of Steps –
2-8
2-9
4. Click OK.
– End of Steps –
3. Right-click the selected record(s), and select the command to execute the CPU use
rate query for processes in logical entities.
– End of Steps –
2-10
2.5 Board
2.5.1 Switching to a Master/Slave OMM Board
This function is just supported by OMMboards.
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Board. The Board tab is displayed.
2. Select a record.
2. Select a record.
3. Right-click the selected record, and select Board power on, see Figure 2-10.
2-11
4. Click OK.
– End of Steps –
2-12
5. Click OK.
– End of Steps –
– End of Steps –
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Board. The Board tab is displayed.
2. Select a record.
3. Right-click the selected record, and select Select clock base. A confirmation dialog
box is displayed, see Figure 2-11.
2-13
– End of Steps –
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Board. The Board tab is displayed.
4. Click OK.
– End of Steps –
2-14
2-15
3. Right-click the selected record, and select Process CPU userate query.
4. View the result.
– End of Steps –
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Board. The Board tab is displayed.
2. Select a record.
3. Right-click the selected record, and select Disk query.
4. View the result.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select PHY CPU userate query.
– End of Steps –
2-16
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Board. The Board tab is displayed.
2. Select a record.
3. Right-click the selected record, and select GPS Status Query.
4. View the result.
– End of Steps –
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Board. The Board tab is displayed.
2. Select a record.
3. Right-click the selected record, and select Board running version query.
– End of Steps –
2-17
2. Select a record.
3. Right-click the selected record, and select DRP Attribute query。
– End of Steps –
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Board. The Board tab is displayed.
2. Select a record.
3. Right-click the selected record, and select Query cell information according to CMP
module.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select Query IMA using information.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select Query ATM optical using information.
– End of Steps –
2-18
Related Tasks
The result of query can be exported to Excel file by clicked Export to excel button.
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Board. The Board tab is displayed.
2. Select a record.
3. Right-click the selected record, perform the following operations as needed:
If Then
– End of Steps –
2-19
2.6 Unit
2.6.1 Querying Unit State
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Unit. The Unit tab is displayed.
2. Select a record.
3. Right-click the selected record, and select Unit state query, see Figure 2-13.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select Slave recover/comeback of RUP unit.
2-20
3. Right-click the selected record, and select DPI card status query of RUP.
4. View the result.
– End of Steps –
2-21
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
Unit. The Unit tab page is displayed.
2. Select a record.
3. Right-click the selected record, and select Query all block RUP unit.
– End of Steps –
3. Right-click the selected record, and select Module state query, see Figure 2-14.
4. View the result displayed in Module state and Module query result columns.
– End of Steps –
2-22
2.8 E1 Sunit
2.8.1 Querying Subunit State
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Physical Resource >
E1 Sunit. The E1 Sunit tab is displayed.
2. Select a record.
3. Right-click the selected record, and select Sunit state query, see Figure 2-15.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select Sunit loop. The Sunit loop dialog box is
displayed.
2-23
4. Select the timeslot No. of loop. Click OK. The result is displayed in the Loop result
column.
– End of Steps –
2-24
2. Select a record.
3. Right-click the selected record, and select Release all loop.
4. View the result in the Loop result column.
– End of Steps –
2.9 T1 Subnit
For the operations on the logical T1 subunit, refer to the operations on the E1 subunit.
2-25
2. Select a record.
3. Right-click the selected record, and select RUP and Slave status query.
2-26
2.12 Association
2.12.1 Querying SCTP Association Status and Key Information
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Transmission Resource
> Sctp Association. The Sctp Association tab is displayed.
2. Select one or several records.
3. Right-click the selected record(s), and select the command to execute the SCTP
association status and key information query.
– End of Steps –
2-27
– End of Steps –
2-28
2.13 M3UA AS
2.13.1 Querying AS State
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Transmission Resource
> M3UA AS. The M3UA AS tab page is displayed.
2. Select one or several records.
3. Right-click the selected records, and select AS state request. The result is displayed
in the Query result column.
– End of Steps –
– End of Steps –
– End of Steps –
2-29
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Transmission Resource
> M3UA ASP. The M3UA ASP tab is displayed.
2-30
– End of Steps –
3. Right-click the selected records, and select the command to execute the MTP3 link
status query (layer 3).
– End of Steps –
2-31
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Transmission Resource
> Signalling Link. The Signalling Link tab is displayed.
2-32
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Transmission Resource
> Signalling Link. The Signalling Link tab is displayed.
2. Select one or several records.
3. Right-click the selected records, and select To deactivate MTP3 link
4. Click OK.
– End of Steps –
2-33
4. Click OK.
– End of Steps –
3. Right-click the selected records, and select the command to execute the link status
query in batch.
– End of Steps –
2-34
3. Right-click the selected records, and select the command to execute the office status
query in batch.
– End of Steps –
3. Right-click the selected records, and select Block or Unblock, see Figure 2-19.
– End of Steps –
3. Right-click the selected records, and select To query the status of MTP2 Link.
– End of Steps –
2-35
2-36
2. Select a record.
3. Right-click the selected record, and select Interface inquiry in RPU, see Figure 2-20.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select Route inquiry in RPU. The Route inquiry
in RPU result page is displayed.
– End of Steps –
2-37
5. Click OK.
– End of Steps –
2-38
3. Right-click the selected record, and select the command to execute LACP packet
sending/receiving query at group interface. A dialog box prompts.
4. Enter a Channel Group No.
5. Click OK.
– End of Steps –
3. Right-click the selected record, and select the command to query channel group
information. A dialog box prompts
4. Enter a Channel Group No.
5. Click OK.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select the command to execute the interface status
query for channel group. A dialog box prompts
2. Select a record.
2-39
3. Right-click the selected record, and select BFD sessions brief query in RPU. The
BFD sessions brief query in RPU result page is displayed.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select BFD sessions detail query in RPU. The
BFD sessions detail query in RPU result page is displayed.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select Policymap query in RPU. The result is
displayed in Policymap query in RPU page.
– End of Steps –
2-40
3. Right-click the selected record, and select Interface query relates to 802.3ah
protocol on RPU. The result is displayed in the Interface query related to 802.3ah
protocol on RPU page.
– End of Steps –
2-41
2-42
2. Select a record.
3. Right-click the selected record, and select Do changeover by BFD in EPU.
– End of Steps –
2-43
– End of Steps –
3. Right-click the selected records, and select ACL4 Specific Table Query.
– End of Steps –
2-44
2-45
– End of Steps –
2-46
3. Right-click the selected records, and select ETHOAM Configuration Query in EPU's
all port.
– End of Steps –
3. Right-click the selected records, and select All PTP Ports Configuration Query.
– End of Steps –
3. Right-click the selected records, and select All PTP Ports State Query.
– End of Steps –
2-47
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > Transmission Resource
> PTP Port. The PTP Port tab is displayed.
2. Select one or several records.
3. Right-click the selected records, and select PTP Unicast Negotiation Query.
– End of Steps –
2-48
2. Select a record.
3. Right-click the selected records, and select QRY APCM.
– End of Steps –
– End of Steps –
2-49
– End of Steps –
Operation Result
Block and release Force block and the services at interface A are release.
Block and no release Block after handover and the services at interface A are
not released.
– End of Steps –
2. Select a record.
3. Right-click the selected records, and select UNB ATRUNK.
4. Click OK.
– End of Steps –
2-50
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> GATRUNKTS. The GATRUNKTS tab is displayed.
2. Select a record.
3. Right-click the selected records, and select SPY ATRUNK.
4. Click OK. The other records that have the same PCM No. with the selected records
are also spied.
– End of Steps –
4. Click OK.
– End of Steps –
2-51
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> ARESPCM. The ARESPCM tab is displayed.
2. Select a record.
3. Right-click the selected records, and select UNBLK ARESPCM.
– End of Steps –
2-52
2-53
3. Right-click the selected records, and select QRY ATERATRUNK, see Figure 2-23.
– End of Steps –
2-54
3. Right-click the selected records, and select QRY MSC, see Figure 2-24.
– End of Steps –
– End of Steps –
2-55
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> MSC. The MSC tab is displayed.
2. Select one or more records.
3. Right-click the selected records, and select UNLD MSC.
– End of Steps –
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> MSC. The MSC tab is displayed.
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> MSC. The MSC tab is displayed.
2-56
2-57
Operation Result
– End of Steps –
2.40 NSVC
2.40.1 Querying NSVC Status
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> NSVC. The NSVC tab is displayed.
2. Select one or several records.
– End of Steps –
2-58
– End of Steps –
2-59
– End of Steps –
2-60
2.44 NSE
2.44.1 Querying NSE Status
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> NSE. The NSE tab is displayed.
2. Select one or several records.
3. Right-click the selected records, and select QRY NSE, see Figure 2-26.
2-61
– End of Steps –
2-62
2.45 Cell
2.45.1 Querying Cell Status
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> BTS. The BTS tab is displayed.
2. Select one or several records.
3. Right-click the selected records, and select Query Cell Status, see Figure 2-27.
– End of Steps –
3. Right-click the selected records, and select Block Cell. A dialog box is displayed, see
Figure 2-28.
2-63
Operation Result
Click Force Block. The cell is blocked and the service is released.
Click Switch Off Block. The cell is blocked after the service is handed
over to other cells.
– End of Steps –
2-64
3. Right-click the selected record, and select Query Channel Statistics in Cell.
– End of Steps –
2-65
2.46 Frequency
2.46.1 Querying TRX Status
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> TRX. The TRX tab is displayed.
2. Select one or several records.
3. Right-click the selected records, and select Query TRX Status, see Figure 2-29.
2-66
– End of Steps –
Operation Result
Click Force Block. The FU (Frame Unit) is blocked and the service
is released.
Click Switch Off Block. The FU is blocked after the service is switched to
other carriers.
– End of Steps –
2-67
Operation Result
Click Force Block. The CU (carrier unit) is blocked and the service
is released.
Click Switch Off Block. The CU is blocked after the service is switched to
other carriers.
– End of Steps –
2-68
3. Right-click the selected record, and select Query Relationship Between TRX and
RRU.
– End of Steps –
2. Select a record.
3. Right-click the selected record, and select Query Up Inter Band.
– End of Steps –
2. Select a record.
3. Right-click the selected records, and select Query TS Status.
– End of Steps –
2. Select a record.
2-69
2.47.3 Blocking TS
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> TS. The TS tab is displayed.
2. Select a record.
3. Right-click the selected records, and select Block TS.
Operation Result
Click Switch Off Block. The TS is blocked after the service is switched to
other carriers.
5. Click OK.
– End of Steps –
2.47.4 Unblocking TS
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> TS. The TS tab is displayed.
2. Select a record.
3. Right-click the selected records, and select Unblock TS.
– End of Steps –
5. Click OK.
2-70
3. Right-click the selected records, and select Query Connect Status by TS.
4. Click OK to close the message box.
– End of Steps –
– End of Steps –
2. Select a record.
3. Right-click the selected records, and select SPY TRX.
– End of Steps –
2-71
2.49 BVC
2.49.1 Querying BVC Status
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> BVC. The BVC tab is displayed.
2-72
2-73
2.50 ABIS
2.50.1 Querying Time Slot Status at Interface Abis
Steps
1. Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource
> ABIS. The ABIS tab is displayed.
2. Select one or several records.
3. Right-click the selected records, and select Query ABIS Status.
– End of Steps –
Operation Result
Click Block and Release. The time slots at interface Abis are blocked and
the service is released.
Click Block and No Release. The time slots at interface Abis are blocked and
the service is not released.
– End of Steps –
2-74
– End of Steps –
2-75
3. Right-click the selected records, and select Query ABIS Device Status.
– End of Steps –
2.53 GSITE
Display the GSITE tab
The GSITE tab can be opened by the step in the Sataus Management tab as fellow:
Select Root Node > GERAN Subnetwork > Managed NE > GSM Radio Resource >
GSITE. The GSITE tab is displayed.
Operations
Select one or more records, Right-click the selected records, some operations can be
selected as fellow:
3. Right-click the selected records, and select Ring Network Status Query.
– End of Steps –
2-76
II