You are on page 1of 5

REAN WATER TECH PVT. LTD.

DESIGN OF FOOTING

ISOLATED FOOTING DESIGN

COLUMN DETAILS : G.L


Size of column B 0.3 m
D 0.35 m

FOOTING DETAILS :
Length = L = 1.65 m
Width = B = 1.65 m 1.20
Depth = D = 0.3 m

Cover to Main R/f = 0.05 m


Diameter of R/f in Footing = 12 mm
0.30
SOIL DETAILS :
Density of Soil = g = 1.7 T/m
3

Depth of foundation below G.L = H = 1.5 m 1.65

MATERIAL CONSTANT :
Concrete Grade = M - 25 N/mm2
R/f Grade = Fe - 415 N/mm2 1.65
Load Factor = gf = 1.5 Z Z

DESIGN FORCES :

Self Weight of Footing = 2.04 T X


1.65

BEARING PRESSURE CALCULATION :


SBC = 12 T/m2 (For DL + LL case)
FOR EARTHQUAKE/WIND CONDITION ALLOWABLE S.B.C = 1.25 x 12 = 15 T/m2
Check for Dl +LL: Max Fy
P = 216.64 kN 21.66 T
Mx = 2.9033333 Knm/m 0.29 T-m
Mz = 8.112 kNm/m 0.81 T-m

V + Mx + Mz
P=
A - Zx - Zz

\ Pmax = 8.71 + 0.39 + 1.0835 = 10.18 T/m2 < S.B.C SAFE


\ Pmin = #REF! 0.39 - 1.0835 = #REF! T/m2 #REF!

Check for Load Case 14 Combination of DL + LL + Wind Load


P = 256.485 kN 25.6485 T
Mx = 5.853 Knm/m 0.5853 T-m
Mz = 10.608 kNm/m 1.0608 T-m

V + Mx + Mz
P=
A - Zx - Zz

\ Pmax = 10.17 + 0.78 + 1.41688 = 12.37 T/m2 < S.B.C SAFE

\ Pmin = 10.17 - 0.78 - 1.41688 = 7.97 T/m2 TENSION NOT CREATED

Check for Load Case 20 Combination of DL + LL + Earth Quake


P = 251.757 kN 25.1757 T
Mx = 3.586 Knm/m 0.3586 T-m
Mz = 27.212 kNm/m 2.7212 T-m

V + Mx + Mz
P=
A - Zx - Zz

\ Pmax = 10.00 + 0.48 + 3.63463 = 14.11 T/m2 < S.B.C SAFE

\ Pmin = 10.00 - 0.48 - 3.63463 = 5.88 T/m2 TENSION NOT CREATED

R/F CALCULATION FROM BENDING CONSIDERATION :

1650

1650 350

300
675
#REF!
T/M2 14.1
T/M2

MOMENT AT CRITICAL SECTION ALONG LENGTH :

M = Pmax x 0.675 x 0.675 / 2


M= 4.82 T-m
Mu = 72.33 KN-m
2
Ast = 849.66 mm ( To be distributed in 1.65 m Length )
Min Req = 360 mm2 ( Ast = 0.12 x b x D )

PROVIDE 12 # @ 125 C/C IN BOTH WAYS

\ Ast = 904.78 mm2

CHECK FOR ONE WAY SHEAR ALONG LENGTH :

Critical Section is at diatance of ' d ' from face of column

1.65 0.675 0.425

1.65

\ Shear force at critical section = #REF! 0.425

V = #REF! T
Vu
\ Actual Shear stress tv =
bxd

1.5 x #REF!
= x 10000
1000 x 250

= #REF! N / mm2

Pt = 100 x As = 100 x 904.78 = 0.36 Pt tc


b x d 1000 x 250 0.25 0.36
0.5 0.49
\ tc = 0.42 N / mm2

> tv

#REF!

CHECK FOR TWO WAY SHEAR :

Critical Section is at distance of 'd/2' from face of column

1.65

0.55

1.65 0.55 d/2

d/2

\ Shear force at Critical Section = 10.18 x Area of Shadeded Portion

= 10.18 x 2.42

= 24.63 T
Critical Perimeter = 3.141 x 0.55

= 1.73 m

Vu
\ Actual Shear stress tv =
bxd

1.5 x 24.63
= x 10000
1727.55 x 244

= 0.877 N / mm2

Allowable Shear stress = ks.tc ( CLAUSE 31.3.3 IS 456 : 2000 )

where,
ks = ( 0.5+b )

Short Side of Column = 0.35


b= Long Side of Column = 0.3
= 1.00

ks = 1.5 but not greater than 1.0

Where,
tc = 0.25  fck
tc = 0.25  M - 25 = 1.25 N/mm2

Allowable Shear stress = ks.tc = 1.25 N/mm2 SAFE

CHECK FOR OVERTURNING :


ALONG LENGTH :

Rm Restoring Moment = 21.66 x 0.83

Rm = 17.87 T.m

Applied Moment = 0.3 T.m

Restoring Moment
F.O.S. =
Applied Moment

P 17.87
= = 61.56
0.290333

> 2.2

SAFE
0.83