MODEL : IGP series (11kw, 22kw, 34kw, 56kw, 67kw) (3 Phase)

Novergy offers grid-connect solar string inverters giving AC voltage output resulting in very high efficiencies and
getting more power from your solar farm.

 Industry best efficiency upto 99%


 Weather-proof design ( IP65 / IP54 ) for outdoor
installation
 MPPT efficiency > 99.9%
 Dual multy MPP Tracker ensures better energy harvest
 Easy-setting multilingual LCD display panel
 Multiple communication interfaces
 High reliability with full protective functions
 Wide DC input voltage range
 Compact design with high quality aluminium housing
 Water-proof direct plug-in terminals

EFFICIENCY CURVE

**
MODELS IGP-B-11kw IGP-B-22kw IGP-B-34kw IGP-B-56kw IGP-B-67kw
INPUT SIZE DATA
Max. PV input power (W) 11000 22000 34000 56200 67500
Max. PV input voltage (V) 1000
Startup voltage (V) 250 280 300 300 620
Nominal input voltage (V) 600 600 620 580 580
MPP voltage range (V) 250-800 480-800 280-950 300-950 570-950
MPP voltage range for nominal power (V) 250-800 480-800 500-850
No. of MPPTs 2 2 2 4 1
Max. Number of PV strings per MPPT 6 6 5 3 12
Max. PV input current (A) 40 42 66 104 120
(Per MPPT channel( (20/20) (21/21) (33/33) (26/26/26/26)
OUTPUT SIDE DATA
Nominal AC output power (W) 10000 20000 34000 50000 60000
Max. AC output current (A) 16 31 48 80 96
Nominal AC voltage 3/N/PE,230/400 Vac
AC voltage range (L-T) 310-480VAC
Nominal grid frequency 50Hz
Grid frequency range 47-52Hz 47-53Hz
THD < 3% (nominal power)
DC current injection < 0.5% In
Power factor > 0.99@ default value at nominal power
PROTECTION
Protections Anti-islanding/DC reverse connection/AC short circuit/Leakage current/ Over
voltage
DC switch Yes
Overvoltage protection Type II surge arrester
SYSTEM DATA
Max. Efficiency (%) 98.1 98.1 98.3 98.9 99
Max. European efficiency (%) 97.2 97.3 98 98.5 98.7
Isolation method Transformerless
Ingress protection rating IP65 (Fan IP55)
Night power consumption < 1W
Operating ambient temperature range -25-60℃ (>45℃ derating)
Allowable relative humidity range 0-95% no condensing
Cooling method Smart forced air cooling
Max. operating altitude 2000m 4000m (>2000m derating)
Display Graphic LCD
Communication RS485 (RJ45 connector)
DC connection type MC4
AC connection type Modular connector Clamping yoke connector Screw clamp
terminal
Certification VDE
MECHANICAL DATA
Dimensions (W*H*D) (mm) 648*695*232 634*820 665*906* 698*959*
*257 257 267
Mounting method Wall bracket
Weight (Kg) 50 55 65 70 55
**Graph is for 50kw inverter Specifications are subject to change without prior notice