• Ultra low power operation, Base on nRF24AP2 • Home/industrial automation
• Simple sync/async serial interface • Environmental sensor networks
.c
• Integrated PCB antenna on board • Active RFID
• On board 32.768 kHz crystal oscillator • Logistics/goods tracking
na
• Broadcast, acknowledged, or burst data transmissions • Audience-response systems
• Minimum message rate per ANT channel 0.5Hz
hi
• Burst transfer rate up to 20Kbps (true data throughput)
• Up to 8 ANT channels for AP2000
qc
• Up to 3 public, managed and/or private network keys
• 1 Mbps RF data rate, GFSK modulation re
• 1.9V to 3.6V supply voltage range
.f
FAMILY MEMBERS
AP1000 – 1 ANT channels, PCB Antenna; surface mount
w
AP1000PA – 1 ANT channels, High RF output Power anout +20dBm; surface mount
AP3000PA – 8 ANT channels with USB2.0 interface, High RF output Power anout +20dBm; surface mount
G
ON
NT
XU
COPYRIGHT ©2011 ALL RIGHTS RESERVED XunTong Tech TEL: +86 10 64390486 +86 755 26675941 E-mail: nrf@freqchina.com 1
Electrical Specifications
Absol ute Maxi mum Rating s
Voltage applied at V C C to V S S -0.3V to +3.6V
Input voltage at any pin -0.3V to V C C + 0.3V ; max +3.6V
Operating temperature -40ºC to +85ºC
Storage temperature -40ºC to +85ºC
Note: Stress exceeding one or m ore of the above maximum ratings may cause permanent damage .
om
.c
na
hi
qc
Pin Pin Name
re
Pin Function Note
Pin1 TEST For Test Only, Not for Use
.f
Pin2 RESET Reset input, low effective
w
COPYRIGHT ©2011 ALL RIGHTS RESERVED XunTong Tech TEL: +86 10 64390486 +86 755 26675941 E-mail: nrf@freqchina.com 2
Host Interface
Serial Interface Mode Setting:
PORTSEL R2 R3 R4 R5 R6
Async Mode VDD Short Open Short Open Open
Sync Mode GND Open Short Open Short Short
Note: PORTSEL is the pin of Module; R2,R3,R4,R5,R6 are on the top of Module.
om
X
.c
na
hi
qc
Typical Application schematic for Async Interface(UART)
re
w .f
ww
CH
TE
G
ON
NT
XU
COPYRIGHT ©2011 ALL RIGHTS RESERVED XunTong Tech TEL: +86 10 64390486 +86 755 26675941 E-mail: nrf@freqchina.com 3
Notes:
• Module RXD and TXD connected directly to hardware USART of microcontroller.
• Switches on baud rate selection pins (BR1, BR2 and BR3) are for ease of use only. They can be
connected directly to the logic level of interest.
• RTS can be connected to an interrupt pin for convenience in some applications. (Interrupt pins
located on Port 1&2 on the MSP430F1232)
om
0 1 1 50000
1 0 0 1200
1 1 0 2400
.c
1 0 1 9600
1 1 1 57600
na
. Relationship between states of speed-select signals and corresponding baud rates
hi
Note: The baud rate may have a significant impact on system current consumption. 。
qc
Sync Mode Application
re
Synchronous
.f
X Bit or byte flow
Interface requires 6 pins to host microcontroller
w
X
ww
CH
TE
G
The Flow Control Select signal is used to configure the synchronous serial port for either Byte or Bit flow
ON
control.
NT
Please note that Byte flow control assumes that the Host contains synchronous communication hardware
which can be configured for synchronous slave communication. Bit flow control can be used by all micro-
controllers. It is especially useful for microcontrollers that offer no HW serial interface, and which require
the serial interface to be emulated in software on the Host MCU.
COPYRIGHT ©2011 ALL RIGHTS RESERVED XunTong Tech TEL: +86 10 64390486 +86 755 26675941 E-mail: nrf@freqchina.com 4
Typical Application schematic for Byte Sync Mode Interface
om
.c
na
hi
qc
re
w .f
ww
CH
Notes:
TE
• Module SOUT, SIN, and SCLK connected directly to hardware USART of microcontroller.
• SEN needs to be on an interrupt capable I/O pin on the microcontroller. (Interrupt pins located on Port
G
COPYRIGHT ©2011 ALL RIGHTS RESERVED XunTong Tech TEL: +86 10 64390486 +86 755 26675941 E-mail: nrf@freqchina.com 5
Typical Application schematic for Bit Sync Mode Interface
om
.c
na
hi
qc
re
w .f
ww
CH
Notes:
• All interface signals are connected directly to I/O pins on the microcontroller.
TE
• SCLK and SEN need to be on an interrupt capable I/O pin on the microcontroller. (Interrupt pins located
on Port 1&2 on the MSP430F1232)
G
ON
NT
Please refer nRF24AP2 Datasheet also refer to the document ANT Message Protocol and Usage when
XU
COPYRIGHT ©2011 ALL RIGHTS RESERVED XunTong Tech TEL: +86 10 64390486 +86 755 26675941 E-mail: nrf@freqchina.com 6
om
.c
na
hi
qc
re
w .f
ww
CH
Attention!
TE
Reserves the right to make changes without further notice to the product to improve reliability, function or design.
COPYRIGHT ©2011 ALL RIGHTS RESERVED XunTong Tech TEL: +86 10 64390486 +86 755 26675941 E-mail: nrf@freqchina.com 7