Natural Gas:
30CDi Regular GC number 41-406-33
40CDi Regular GC number 41-406-35
L.P.G:
30CDi Regular GC number 41-406-34
40CDi Regular GC number 41-406-36
UK/IE
6 720 812 177 (2014/07)
Preface
8 Your guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
9 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
BENCHMARK STANDARD
The Benchmark initiative is a
code of practice to encourage the
correct installation,
commissioning and servicing of
domestic central heating boilers
and system equipment.
A “checklist” is dispatched with every boiler. This is a vital
document that needs to be completed by the installer at the
time of installation. It confirms that the boiler has been
installed and commissioned according to the manufacturer's
instructions.
The log book provides space for the recording of regular
servicing of the boiler/heating system and this can become a
valuable document when, for example, you wish to sell the
property. The log book will show a potential purchaser that the
heating system has received regular professional maintenance
and servicing during its lifetime.
The Benchmark initiative aims to:
• Raise standards among professional installers
• Build and maintain high safety standards in the industry
• Improve customer satisfaction levels
• Make a contribution to the nation's commitment to climate
change
10 1
9 reset
2
8 eco
3
7 4
6720806548-14.1Wo
3 4
2 5
6 1
max
6
5
10
reset
eco
3 4
5
2 5
1 6
max
6720806549-01.1Wo
Fig. 2
The boiler runs for 15 minutes at minimum heating output to fill the condensate trap. The display alternates
between and the central heating flow temperature.
This occurs every time the mains supply has been interrupted.
Switching off
▶ Switch off the boiler by pressing the ON/OFF button.
The ON/OFF indicator light goes out.
9
reset
eco
3 4
2 5
6
1 6
max
6720806549-02.1Wo
Fig. 3
10
reset
eco
3 4
2 5
1 6
6 max
6720806549-03.1Wo
Fig. 4
To activate frost protection:
▶ Leave power [10] switch on.
▶ Turn the central heating temperature control [6] to .
reset
eco
2
3 4
2 5
max
6
5
6720806549-04.1Wo
Fig. 5
To reset the boiler:
▶ Press the reset button [2] for three seconds.
The reset button [2] and the ON/OFF indicator [5] will stop
flashing.
The boiler will function normally, dependent on
programmer and room thermostat settings.
4 MAINTENANCE
Your new Greenstar CDi Classic Regular gasfired appliance If you would like to know more about a Worcester Bosch service
represents a long term investment in a reliable, high quality contract, please tick the appropriate box on your warranty
product. registration card.
In order to realise its maximum working life, and to ensure it If your Greenstar CDi Classic Regular should fail to operate
continues to operate at peak efficiency and performance, it is correctly or requires servicing please contact the Worcester
essential that your boiler receives regular servicing and Bosch Service Department (see back page cover for details).
maintenance checks from a competent person beyond the
initial 2 year guarantee period. Details of the boiler including the Gas Council number can be
found under the controls cover flap on the boiler.
When calling Worcester, Bosch Group, you may be asked for the error code. This Table is for you to help identify
the possible cause of the fault.
▶ Do not try to rectify any of the faults listed below by yourself.
▶ Contact British Gas or a competent, qualified engineer (Gas Safe registered personnel).
8 YOUR GUARANTEE
This boiler has a guarantee against faulty materials or GUARANTEE REGISTRATION
workmanship for a period of two years from the date of Your Greenstar boiler carries a two year guarantee against
installation subject to the following terms and conditions: faulty material or manufacture subject to Terms and
• During the period of this guarantee any components of the Conditions.
boiler which are proven to be faulty or defective in To read the full Terms & Conditions please visit us on-line at
manufacture will be exchanged or repaired free of charge www.worcester-bosch.co.uk/guarantee. The Guarantee
by Bosch Thermotechnology Ltd. Registration form is available on this same page and can be
• The householder may be asked to prove the date of completed and submitted electronically.
installation, that the boiler was correctly commissioned Alternatively please telephone one of our Guarantee
and, where appropriate, the first year's service has been Registration advisors on 0330 123 9559.
carried out to the satisfaction of Bosch Thermotechnology Your statutory rights are not affected by the manufacturers
Ltd., when requested. These should be documented as a guarantee.
part of the Benchmark Checklist. FOR YOUR OWN RECORD:
• The boiler has been used only for the normal domestic Please ensure that the Benchmark Checklist has been
purposes for which it was designed. completed by your installer or service engineer.
This guarantee does not affect your statutory rights.
Model
Serial No.1)
Type/size
Date of installation
Name of Installer
Telephone number of Installer
Table 5
1) See boiler identification label on boiler fascia or Benchmark Checklist in the back of the Installation, Commissioning & Servicing
Instructions.
9 GLOSSARY
Central heating systems
All radiators must be heated at an even rate. If the top of a
radiator is at a lower temperature than the bottom then it
should be bled by releasing air through the bleed screw at the
top of the radiator.
Ask your installer to show you how this is done.
This boiler is fitted to a sealed system. Should water leaks be
found or if excessive bleeding is required, then a service
engineer must be contacted to inspect the installation and
rectify any fault.
Only additives that are compatible with aluminium may be used
in the system. Any incompatible additive used will invalidate
the guarantee.
Pluming and Condensate drain
This is a condensing boiler and the flue terminal will, at times
give out a plume of water vapour. This is quite normal.
The boiler produces condensate which is discharged regularly
by a syphon within the boiler via a plastic pipe to a drain. This
pipe must not be blocked or altered in any way.
Room thermostat / programmer
A room thermostat / programmer must be fitted to control the
central heating. This controls the times and temperatures of
the central heating, preventing the boiler from firing
unnecessarily. Refer to the instructions supplied with the
thermostat and programmer for further information.
Thermostatic radiator valves
Thermostatic radiator valves must be fitted in sleeping
accommodation. It is recommended that this type of valve is
fitted to all but one of the radiators. The remaining radiator,
where the room thermostat is located, must be uncontrolled
and left open.
Pump over run function
After the boiler has finished a demand for central heating or hot
water, the pump may continue to run for a short while to
dissipate the heat from within the boiler.
Pump anti-seizure
If there has been no heating demand for 24 hours the boiler will
run the system pump for a few seconds to reduce the
possibility of pump seizure during long periods of inactivity.
SEDBUK
Seasonal Efficiency of Domestic Boilers in the UK.
worcester-bosch.co.uk