Name : Putu Widhi Aprilia

PIPELINE ENGINEERING
NRP : 04211540000017
Class : Rekayasa Pipa
WALL THICKNESS CALCULATION
Lecturer : Nurhadi Siswantoro

1. DESIGN DATA
a Pipeline Design Data
Design flow rate : 275 MMSCFD
Fluid : Natural Gas
Design Pressure : 1150 psig
Max Operating Press : 1050 psig
Min Operating Press : 300 psig
Max Design Temp : 150 F
Min Design Temp : 68 F
Design Life : 20 Years

b Pipe Specification
Material Grade : API 5L X 65
SMYS : 65000 psi
Nominal Diameter : 32 inch

c Earth Cover
Min cover at road crossings : 2 m
Min cover at rail crossings : 2 m

d Bends
Field Bend Radius :
Minimum 30 DR with a minimum
2 meter straight pipe at both ends
Shop introduction bend radius : Minimum 5 DR

2. PRESSURE DESIGN WALL THICKNESS


Based on ASME B31.8, the pressure design wall thickness is calculated by
the following formula:

𝑃�/2𝑆𝐹𝐸�
t=

Where,
t = pressure design wall thickness, inch
P = design pressure, psig
D = outside diameter, inch
S = specified minimum yield strength, psi
F = design factor
= 0.8 location class 1, division 1
= 0.72 location class 1, division 2
= 0.6 location class 2
= 0.5 location class 3
= 0.4 location class 4
= 0.6 location class 1, division 2 for
road crossing
= 0.5 location class 2, division 3 for
road crossing
E = Longitudinal joint factor
= 1 for API 5 L submerged arc Welded Pipes

T = Temperature Derating Factor


1 for temperature 250 F or less
1 inch = 25.4 mm

a. Pressure design wall thickness at location class 1 division 1

𝑃�/2𝑆𝐹𝐸�
t=

t= 1150 x 32
2 x 65000 x 0,8 x 1 x 1

t= 0.3538461538 inch
t= 8.9876923077 mm
According to ASME B36.10M, choosen pipe's wall thickness is
0.375 in

b. Pressure design wall thickness at location class 1 division 2

𝑃�/2𝑆𝐹𝐸�
t=

t= 1150 x 32
2 x 65000 x 0,72 x 1 x 1

t= 0.3931623932 inch
t= 9.9863247863 mm
According to ASME B36.10M, choosen pipe's wall thickness is
0.438 in

c. Pressure design wall thickness at location class 2

𝑃�/2𝑆𝐹𝐸�
t=

t= 1150 x 32
2 x 65000 x 0,6 x 1 x 1

t= 0.4717948718 inch
t= 11.9835897436 mm
According to ASME B36.10M, choosen pipe's wall thickness is
0.5 in

d. Pressure design wall thickness at location class 3

𝑃�/2𝑆𝐹𝐸�
t=

t= 1150 x 32
2 x 65000 x 0,5 x 1 x 1

t= 0.5661538462 inch
t= 14.3803076923 mm
According to ASME B36.10M, choosen pipe's wall thickness is
0.625 in

e. Pressure design wall thickness at location class 4

𝑃�/2𝑆𝐹𝐸�
t=

t= 1150 x 32
2 x 65000 x 0,4 x 1 x 1

t= 0.7076923077 inch
t= 17.9753846154 mm
According to ASME B36.10M, choosen pipe's wall thickness is
0.75 in

3. SUMMARY
Location class Class 1 Div1 Class 1 Div2 Class 2 Class 3 Class 4
Design factor 0.8 0.72 0.6 0.5 0.4
Pipe wall thickness (in) 0.353846 0.393162 0.471795 0.566154 0.707692
Selected pipe wall thickness (in) 0.375 0.438 0.5 0.625 0.75
Schedule No. Sch 10 Sch 10 Sch 20 Sch 30 Sch 40