DRILLED PILE

PROJECT :
CLIENT :
JOB NO. :
st-in-place Pile Design Based on ACI 318-05

DESIGN CRITERIA
ITION IF Ldh & Lhk1.COMPLY WITH THE TENSION DEVELOPMENT. OTHERWISE PINNED AT TOP.
ADS & REACTIONS, 2. DETERMINE MAX SECTION FORCES OF SINGLE PILE, P u, Mu, & Vu.

NPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc' = 3
VERT. REBAR YIELD STRESS fy = 60
PILE DIAMETER D = 24
PILE LENGTH L = 35
FACTORED AXIAL LOAD Pu = 100
FACTORED MOMENT LOAD Mu = 200
FACTORED SHEAR LOAD Vu = 20
PILE VERT. REINF. 8 # 7
SEISMIC DESIGN (ACI 21.10.4) ? Yes
RAL REINF. OPTION (0=Spirals, 1=Ties) 1
LATERAL REINFORCEMENT # 4 @ 6
(spacing 3.0 in o.c. at top end of 10.0 ft.)
(IBC/CBC 1810 & ACI 21.10.4)
( Ldh = 10.735362 in & Lhk =

THE PILE DESIGN IS ADEQUATE.

ANALYSIS
CHECK PILE LIMITATIONS
fc' = 3 ksi > 2.5
D= 24 in > MAX( L / 30 , 12 in)

ECK FLEXURAL & AXIAL CAPACITY

Page 1
DRILLED PILE

f Pmax =F f [ 0.85 fc' (Ag - Ast) + fy Ast] =


where F = , ACI 318-05,
0.8 Sec. 10.3.6.1 or 10.3.6.2
f = 0.65
(ACI 318-05, Sec.9.3.2.2)
Ag = 452.38934 in2.

f Pn (k)

f Mn (ft-k)
a = Cbb1in=(at10.092597
balanced strain condition, ACI 10.3.2)
0.7f += ( et - 0.002 ) (200 / 3), for Spiral
0.65 + ( et - 0.002 ) (250 / 3), for Ties
where Cb = d ec / (ec + es) = 11.873644
d = 20.0625 in, (ACI 7.7.1)
f Mn = 0.9 Mn @
ft-kips 318-05, Sec. 9.3.2) ,& et,max = 0.004, (ACI 318-05, Sec. 10.3.5)
= Pn = 0, (ACI173.50678
f Mn = 233.54893 ft-kips @ Pu = 100
rmax = 0.08
(ACI 318-05, Section 10.9)
rmin = 0.005
(IBC, Section 1810.1.2.2)

CHECK SHEAR CAPACITY


f Vn = f (Vs + Vc) = 86.159887
kips, (ACI 318-05 Sec. 11.1.1)
> Vu [Satisfactory]
where f = 0.75
(ACI 318-05 Sec. 9.3.2.3)
A0 = 316.12583 in2.
Vc = 2 (fc')0.5A0 = 34.629849
VsMIN = (d fy Av / s , 8 (fc')0.5A0) =
smax = (IBC
10.5 06 , Section 1810.1.2.2)
smin = 1
rs = 0.12 fc' / fyt = 0.006 < rs,provd =

Page 2
DRILLED PILE

ETERMINE FIX HEAD CONDITION

Lhk = in,
14(ACI 318-05, Fig. R12.5)

where db = 0.875 in
r required / r provided = 0.8
ye = (1.2 for epoxy-coated,
1 ACI 318-05 12.2.4)
l = 1 (normal weight)
h = (#11 or 0.7
smaller, cover > 2.5" & side >2.0",

Page 3
DRILLED PILE

DATE :

ksi
ksi
in
ft
k
ft-k
k

Ties
in o.c.
o.c. at top end of 10.0 ft.)
1810 & ACI 21.10.4)

14 in )

ksi [Satisfactory] (IBC 1810.1.1)


( L / 30 , 12 in) [Satisfactory] (IBC 1810.3.2)

Page 4
DRILLED PILE

kips., (at743.26347
max axial load, ACI 318-05, Sec. 10.3.6.2)

> Pu
Ast = 4.8 in2.

AT COMPRESSION ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT e t = 0.002
AT BALANCED CONDITION
AT e t = 0.005
AT FLEXURE ONLY
AT TENSION ONLY

= 0.65575
(ACI 318-05, Fig. R9.3.2)

in et = 0.002069 ec = 0.003
b1 = (0.85
ACI 318-05, Sec. 10.2.7.3 )
318-05, Sec. 10.3.5)
kips > Mu [Satisfactory]
rprovd = 0.0106103
[Satisfactory]

Satisfactory]
Av = 0.4 in2. fy = 60 ksi
s, (ACI 318-05 Sec. 11.3.1, 11.3.1.3)
kips, (ACI
80.25
318-05 Sec. 11.5.7.2 & 11.5.7.9)
sprovd = 6 in
[Satisfactory]
0.0081019[Satisfactory]
(ACI 318-05 Sec. 21.10.4.4 & 21.4.4.1)

Page 5
DRILLED PILE

12.268985 db = 10.735362 in
(ACI 318-05 12.5.2)

( A s,reqd / A s,provd , ACI 318, 12.2.5)


18-05 12.2.4)

& side >2.0",


ACI 318-05 12.5.3)

Page 6
DRILLED PILE

PAGE :
DESIGN BY :
REVIEW BY :

Page 7
DRILLED PILE

[Satisfactory]

(cont'd)

f Pn (kips) f Mn (ft-kips)
743.26347 0
743.26347 107.9925446
639.47248 161.3073558
526.51324 197.808957
431.62507 214.5571456
288.41013 221.9355206
281.91846 223.8399904
95.916702 233.7668596
0 173.5067764
-259.2 0

Satisfactory]

Satisfactory]

Satisfactory]

Page 8