Casing data
panel thickness [mm] 50,0
Panel outside galvanized coated RAL 7035 GL S
Panel inside galvanized steel
Panel inside bottom galvanized steel
Profiles aluminium coated
Guides galvanized steel
Insulation Rockwool
Supply air
Size KEK 6 Velocity class V6
Airflow [m³/h] 11.000 air vel.at unit cr-s [m/s] 2,55
Ext. pressure [Pa] 350 specific fan power [W/(m3/s)] 1.646
Tot. pressure [Pa] 1.166 SFP Class SFP3
Power class P1
Exhaust air
Size KEK 6 Velocity class V6
Airflow [m³/h] 11.000 air vel.at unit cr-s [m/s] 2,55
Ext. pressure [Pa] 300 specific fan power [W/(m3/s)] 1.122
Tot. pressure [Pa] 759 SFP Class SFP2
Power class P1
Baseframe
Material galvanized steel Height [mm] 100,0
roof Type one-sided roof type flat Area [m2] 11,12
Material galvanized coated Inclined angle [mm] 55,0
1 set Rubber slabs under AHU's (vibration insolaters) PKL loose GENB03
1 set Safety labels ISO 3864-2 PKL Mounted DOCL01
1 set Transport remarks PKL Mounted DOCL04
1 Pcs Assembly instructions PKL loose DOCM01
Weatherproff casing Mounted CASC19
Standard transport packing Mounted GENP01
Notes Version 3.20.132/47
* Casing material combinations reference to casing section
- /- /- = mat.pan inside / material bottom sh. inside / mat.guides - = Standard
Ambient data sea level of destination 0m
ambient temperature 20,00 °C air pressure 1.013 mbar
ambient humidity 30,0 % air density [kg/m³] 1,20
Transport length [m] 4,9 Total weight [kg] 1.870,00 !!!!
Aircalc++
130 130
55
55
34
40
40
Version
K3G355-PH49-06
M3G112GA
ETA M5 1.9 kW ODA
770
690
690
770
3.20.132
M5
40
40
40
40
1.540
1.695
47
K3G400-AQ23-01
M3G150FF
System
SUP F8 3 kW EHA
770
690
690
770
2R 2R
CK2 CH2
40
40
100
100
Premium modular AHU
130 130
AHU 04
KEK 6-M-DV50P-S
40
40
Printed
1691
1.885
1.805
1.805
1.885
1.962
14.03.2018
TP
40
40
77
7 / 11
Position 34 System AHU 04 Offer 1691 TP
Exhaust air
Psychrometric Chart
Moisture content [g/kg]
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
42
101.325 [kPa]
37 10% 35 °C / 35 %
33,5 °C / 32 %
1,15 [kg/m3]
32 20%
P3
P4 27,5 °C / 54 %
30% 26 °C / 50 %
27
40%
23 °C / 3,04 % 23 °C / 67,74
P6 %
50%
22
1,20
18 °C / 40 % 70%
60
90%
17 15 P5
°C / 7 %
Temperature [°C]
1210 °C / 7 % 40 [kJ/kg]
1,25
7
P2
20
2
P1
1,30
-3
-7,3 °C / 100 % t °C r % x g/kg h kJ/kg tw °C t °C r% x g/kg h kJ/kg tw °C
-8 0 P1 CPTW -18,00 90 0,69 -16,40 -18,16 15,00 7 0,73 16,94 4,16
P2 CPTW 18,00 40 5,11 31,05 10,79 -7,30 100 2,03 -2,30 -7,30
-13 P3 CPTS 35,00 35 12,33 66,83 22,74 27,50 54 12,42 59,34 20,62
P4 CPTS 26,00 50 10,50 52,90 18,70 33,50 32 10,34 60,18 20,91
-18 °C / 90 %
-18 P5 CH2 10,00 7 0,53 11,39 1,11 23,00 3 0,53 24,47 7,90
P6 CK2 27,50 54 12,42 59,34 20,62 23,00 68 11,91 53,42 18,83
Noise chart
Supply air
100
90
80
70
60
[dB]
50
40
30
20
10
0
63 125 250 500 1000 2000 4000 8000
[Hz]
LWA casing LWA in LWA out SPL casing SPL in SPL out
Exhaust air
90
80
70
60
[dB]
50
40
30
20
10
0
63 125 250 500 1000 2000 4000 8000
[Hz]
LWA casing LWA in LWA out SPL casing SPL in SPL out
11.05.518
PRO-KLIMA d.o.o. participates in the ECC programm for Air Handling units (AHU);Check ongoing validity of
certificate online: www.eurovent-certification.com or using www.certiflash.com. Certificate No. 11.05.518
mechanical stability class Casing leaky class at 400 Pa Filter bypass leakage class
EN 1886 (M) EN 1886 (M) EN 1886