You are on page 1of 8

®

STORMWATER DETENTION SYSTEM


®
More Stormwater
Less Space

STORMWATER MANAGEMENT
Is your stormwater detention system taking up too much space? Bring it down to size with the R-Tank System, the
PRVWHɝFLHQWDQGYHUVDWLOHXQGHUJURXQGVWRUPZDWHUVWRUDJHV\VWHPDYDLODEOHWRGD\:KHWKHU\RXQHHGWRUHGXFH
\RXUV\VWHPIRRWSULQWWRUHVROYHDXWLOLW\FRQȵLFWRUIUHHXSVSDFHIRUDIXWXUHH[SDQVLRQ57DQNZLOOJLYH\RXWKH
VPDOOHVWIRRWSULQWSURYLGHPRUHRSWLRQVIRUYHKLFXODUORDGLQJDQGFRYHUGHSWKVDQGGHOLYHUPRUHLQVWDOODWLRQ
YHUVDWLOLW\WKDQDQ\RWKHUV\VWHPDURXQG

7KH57DQN6\VWHPLQFOXGHVȴYHGL΍HUHQWPRGXOHFRQȴJXUDWLRQV
SURYLGLQJV\VWHPKHLJKWRSWLRQVIURPȋWRRYHUȇWDOO$QGLWGHOLYHUV
VXSSRUWIRU+6DQG+6WUDɝFZLWKFRYHUGHSWKVIURPȋDOOWKH
ZD\XSWRRYHUȇ:KHWKHU\RXȇUHGHVLJQLQJDSURMHFWDWWKHEHDFK
ZLWKPLQLPDOGHSWKRYHUWKHZDWHUWDEOHRUDGHHSV\VWHPLQWKHKLOOV
57DQNKDV\RXFRYHUHG

:LWKDQXQOLPLWHGDUUD\RIV\VWHPIRRWSULQWVDQGFRQȴJXUDWLRQV
57DQNVROYHVWRXJKVWRUPZDWHUSUREOHPVE\SHUIHFWO\DGDSWLQJWR
WKHQHHGVRI\RXUVLWH*LYH57DQNDVKRWRQ\RXUQH[WSURMHFWDQG
SUHSDUHWREHLPSUHVVHG

2
R-TANK®
®

z /LJKW'XW\PRGXOH SVL
BENEFITS  z ΖGHDOIRUDSSOLFDWLRQVLQJUHHQVSDFH
High Capacity
 z 1RWUDWHGIRUYHKLFXODUWUDɝF
z YRLGLQWHUQDODUHD
 z ȋ0LQLPXPFRYHUȋPD[LPXPFRYHU

z )RXULQWHUQDOSODWHV
Strength
z  (DVLO\VXSSRUWVWUDɝFORDGLQJIURPSDUNLQJORWV
and roads
 z 0RGXOHRSWLRQVIRU+6DQG+6UDWLQJZLWK
®
FRYHUGHSWKVIURPLQFKHVWRIHHW
z +HDY\'XW\PRGXOH SVL
z 6WDQGDUGPRGXOHIRU+6WUDɝF
Design & Construction Versatility   DSSOLFDWLRQV
z  &RPELQHPRGXOHVLQWRDQ\VKDSHWRHɝFLHQWO\  z ȋ0LQLPXPFRYHU

use space   ȋ0D[LPXPFRYHU


 z 9DU\KHLJKWIURPLQFKHVWRIHHW z )LYHLQWHUQDOSODWHV

ΖQFUHDVHGΖQȴOWUDWLRQDQG([ȴOWUDWLRQ
z  2XWHUVKHOOLVRSHQ
z Increases groundwater recharge, reducing post- ®

 FRQVWUXFWLRQGLVFKDUJHYROXPHV z 6XSHU'XW\PRGXOH SVL


z +LJKHUVDIHW\IDFWRUVIRUVKDOORZWUDɝF
  DSSOLFDWLRQVDQGGHHSHUFRYHU
(DV\WR7UDQVSRUW
 z ȋ0LQLPXPFRYHU
z &DQEHVXSSOLHGXQDVVHPEOHGIRUUHGXFHG
  ȋ0D[LPXPFRYHU
 GHOLYHU\FRVWV
z )LYHLQWHUQDOSODWHV

Lightweight and Quick to Install


z ΖQVWDOOHGE\KDQGQRFUDQHVUHTXLUHG
 z 5HGXFHVVLWHDFFHVVGHOD\V
z 8OWUD'XW\PRGXOH SVL
z 7UDɝFORDGVZLWKȋRIFRYHU
Recycled Content
$YDLODEOHIURPȋȂȋWDOO
 0DQXIDFWXUHGZLWKUHF\FOHGSRO\SURS\OHQH
z
z
z ΖGHDOIRUKLJKZDWHUWDEOHVLWHV

®
z ([WUHPH'XW\PRGXOH SVL
 z 7UDɝFORDGVZLWKȋFRYHU

 z ȇPD[LPXPFRYHU

z $YDLODEOHIURPȋȇWDOO
z YRLG
3
DESIGN CONSIDERATIONS
0DQ\IDFWRUVZLOOLQȵXHQFHWKHGHVLJQ 727$/&29(5´0,1,080$1'´0$;,080),567´0867%(
)5(('5$,1,1*%$&.),// 63(&6(&7,21% 6721(´2562,/
NOTES:
1. FOR COMPLETE MODULE DATA, SEE APPROPRIATE R-TANK୪୦MODULE SHEET .

of the R-Tank®V\VWHP:KLOHWKLVOLVWLV
(USCS CLASS GW, GP, SW OR SP). ADDITIONAL FILL MAY BE 2. INSTALLATIONS PER THIS DETAIL MEET GUIDELINES OF HL-93 LOADING PER THE AASHTO LRFD
STRUCTURAL FILL (SPEC SECTION 2.03C): STONE OR SOIL (USCS BRIDGE DESIGN SPECIFICATIONS, CUSTOMARY U.S. UNITS, 7TH EDITION, 2014 WITH 2015 AND
CLASS SM, SP, SW, GM, GP OR GW) WITH MAX CLAY CONTENT<10%, 2016 INTERIM REVISIONS.
MAX 25% PASSING NO. 200 SIEVE, AND MAX PLASTICITY INDEX OF 4. A 3. PRE-TREATMENT STRUCTURES NOT SHOWN.

QRWLQWHQGHGWREHDOOLQFOXVLYHVHY-
0,1´&29(50867%(0$,17$,1('%(7:((1%$&.),// 4. FOR INFILTRATION APPLICATIONS, GEOTEXTILE ENVELOPING R-TANK SHALL BE ACF M200 (PER
(48,30(17$1'7+(7232)7+(57$1.Œ6<67(0$7$//7,0(6 SPEC SECTION 2.02A) AND BASE SHALL BE 4" MIN. UNCOMPACTED FREE DRAINING BACKFILL
TOTAL HEIGHT OF TOP BACKFILL SHOULD NOT EXCEED 7'. CONTACT (SPEC SECTION 2.03A) TO PROVIDE A LEVEL BASE. SURFACE MUST BE SMOOTH, FREE OF LUMPS
ACF ENVIRONMENTAL IF MORE THAN 7' OR LESS THAN 20" OF TOP OR DEBRIS, AND EXTEND 2' BEYOND R-TANK୪୦ FOOTPRINT.

HUDOGHVLJQFRQVLGHUDWLRQVDUHZRUWK BACKFILL IS REQUIRED (FROM TOP OF TANK TO TOP OF PAVEMENT).


*(2*5,' 7(16$5%;25(48$/ 3/$&('´$%29(7+(
R-TANK୪୦6<67(029(5/$3$'-$&(173$1(/6%<´0,1

KLJKOLJKWLQJ
GEOGRID SHOULD EXTEND 3' BEYOND THE EXCAVATION FOOTPRINT.
PAVED
UTILITY MARKERS AT 36" (0.91 m) MIN. COVER FROM FINISH
SURFACE
CORNERS (TYP.) GRADE TO TOP OF TANK:
20" (0.51 m) MIN.
84" (2.13 m) MAX.

1. PRE-TREATMENT 12" (0.30 m)


OPTIONAL

2. BACKFILL MATERIALS OVERFLOW


PIPE
INLET PIPE

3. RUNOFF REDUCTION OPTIONAL

4. WATER TABLE OUTLET


PIPE

5. CONSTRUCTION LOADS
3" (0.08 m) MIN.

6. LATERAL LOADS 57$1.୪୦81,76:5$33(',12=


24" (0.61 m)

7. R-TANK® MODULES NONWOVEN GEOTEXTILE (OR EQUAL)


LOAD RATING: 33.4 PSI (MODULE ONLY)
%$6(´0,1%('',1*0$7(5,$/ 63(&6(&7,21
$ 0$<%(6721( ´ 2562,/ 86&6&/$66*:
GP, SW OR SP). MUST BE FREE OF LUMPS AND DEBRIS,
SIDE BACKFILL: 24" MIN. OF FREE DRAINING
%$&.),// 63(&6(&7,21% 6721(´
OR SOIL (USCS CLASS GW, GP, SW OR SP).

8. LOAD MODELING
SUBGRADE / EXCAVATION LINE: COMPACT PER AND EXTEND 2' BEYOND R-TANKHD. COMPACT PER MUST BE FREE FROM LUMPS, DEBRIS AND
SPEC SECTION 3.02 D. A BEARING CAPACITY SPEC SECTION 3.03 A. NATIVE SOILS MAY BE USED IF OTHER SHARP OBJECTS. SPREAD EVENLY TO
OF 2,000 PSF MUST BE ACHIEVED PRIOR TO THEY MEET THE REQUIREMENTS OF SPEC SECTION 35(9(1757$1.୪୦029(0(17&203$&7
INSTALLING R-TANKHD 2.03A AND ARE ACCEPTED BY OWNER'S ENGINEER. SIDE BACKFILL WITH POWERED MECHANICAL
COMPACTOR IN 12" LIFTS (PER SPEC SECTION
3.05 A2).

1. PRE-TREATMENT 5. CONSTRUCTION LOADS


5HPRYLQJSROOXWDQWVIURPUXQR΍EHIRUHWKH\HQWHUDQ &RQVWUXFWLRQORDGVDUHRIWHQWKHKHDYLHVWORDGVWKH
XQGHUJURXQGGHWHQWLRQV\VWHPLVWKHRQO\VPDUWZD\ V\VWHPZLOOVHHWKURXJKRXWLWVOLIH&DUHPXVWEH
WRGHVLJQ EXLOGDV\VWHP7KHEHVWZD\WRGRWKDW WDNHQGXULQJEDFNȴOOLQJDQGFRPSDFWLRQXVLQJWKH
LVZLWKWKH7UDVK*XDUG3OXV® VHHSDJH EXWPDQ\ SURSHUHTXLSPHQW VHHVSHFLȴFDWLRQVHFWLRQ DQG
RWKHUZD\VH[LVW%HVXUHWKHV\VWHP\RXVHOHFWZLOO SRVWLQVWDOODWLRQFRQVWUXFWLRQWUDɝFVKRXOGEHURXWHG
UHPRYH DURXQGWKHV\VWHP ΖQVWDOODWLRQ*XLGHVWHS 
 z+HDY\6HGLPHQWV
 z*URVV3ROOXWDQWV WUDVK 6. LATERAL LOADS
 z%LRGHJUDGDEOH'HEULV $VV\VWHPVJHWGHHSHUWKHORDGVDFWLQJRQWKHVLGHV
RIWKHWDQNLQFUHDVH:KLOHYHUWLFDOORDGVRIWHQFRQWURO
2. BACKFILL MATERIALS WKHGHVLJQEHVXUHWRFRQVLGHUODWHUDOORDGLQJDVZHOO
%DFNȴOOPDWHULDOVVKRXOGEHVWRQH VPDOOHUWKDQȋ
LQGLDPHWHU RUVRLO *:*36:RU63DVFODVVLȴHGE\ 7. R-TANK MODULES
WKH8QLȴHG6RLO&ODVVLȴFDWLRQ6\VWHP 0DWHULDOPXVW %HVXUHWRVHOHFWWKHULJKWPRGXOHIRU\RXUDSSOLFD-
EHIUHHIURPOXPSVGHEULVDQGDQ\VKDUSREMHFWVWKDW WLRQ6HHWKHLQIRUPDWLRQRQSDJHIRUPRUHGHWDLOV
FRXOGFXWWKHJHRWH[WLOH6HHWKH57DQN®QDUUDWLYH RQZKLFKPRGXOHLVWKHEHVWȴW$OVRUHIHUWRWKH
VSHFLȴFDWLRQVHFWLRQIRUDGGLWLRQDOLQIRUPDWLRQ VSHFLȴFDWLRQVIRUHDFKPRGXOHRQWKHEDFNRIWKLV
EURFKXUHRUFDOOXVIRUDVVLVWDQFH
3. RUNOFF REDUCTION
0RVWGHVLJQVLQFRUSRUDWHDQRXWOHWWRGUDLQWKHV\V- 8. LOAD MODELING
WHPDWDFRQWUROOHGUDWHDQGRUDQRYHUȵRZWRSUH- $VDIHW\IDFWRURIRUKLJKHULVUHTXLUHGZKHQ
YHQWȵRRGLQJLQH[WUHPHHYHQWV%XWEHVXUHWRWDNH GHVLJQLQJDQ57DQN6\VWHPXVLQJWKH$$6+72/5)'
DGYDQWDJHRIDQ\LQȴOWUDWLRQ\RXFDQDFKLHYHRQWKH %ULGJH'HVLJQ6SHFLȴFDWLRQV%HVXUHWRUXQ\RXURZQ
VLWH&RQVLGHUUDLVLQJWKHLQYHUWRI\RXURXWOHWRUFUHDW- ORDGLQJPRGHOZLWKDOOUHTXLUHPHQWVVSHFLȴFWR\RXU
LQJDVXPSWRFDSWXUHDQGLQȴOWUDWHWKHZDWHUTXDOLW\ VLWH6HYHUDOH[DPSOHPRGHOVFDQEHIRXQGLQRXU
YROXPHZKHQHYHUSRVVLEOH 7HFK1RWHRQORDGLQJFDSDELOLWLHVDQGPLQLPXPFRYHU
UHTXLUHPHQWVIRUYDULRXVORDGVFDQEHIRXQGLQWKH
4. WATER TABLE VSHFRQWKHEDFNRIWKLVEURFKXUH
:KLOHLQVWDOOLQJWKH57DQN®EHORZWKHZDWHUWDEOHLV
PDQDJHDEOHGHVLJQHUVPXVWEHDEOHWRFUHDWHDVWD-
EOHEDVHDQGDFFRXQWIRUWKHV\VWHPȇVDELOLW\WRGUDLQ
WKLVZDWHURXWRUOLPLWLWVDELOLW\WRHQWHUWKHV\VWHPΖI
DOLQHULVXVHGWRSUHYHQWJURXQGZDWHUIURPHQWHULQJ
WKHV\VWHPPHDVXUHVPXVWEHWDNHQWRSUHYHQWWKH
V\VWHPIURPȵRDWLQJ

LOW IMPACT DESIGN AND GREEN INFRASTRUCTURE
AVPXFKRIWKHQDWLRQȇV*UD\ΖQIUDVWUXFWXUHFRQWLQXHVWRGHFD\QHZFRQFHSWVIRUDEHWWHUZD\WRUHEXLOG
LWDUHHPHUJLQJWKURXJK*UHHQΖQIUDVWUXFWXUH *Ζ DQG/RZΖPSDFW'HYHORSPHQW /Ζ' 7KLVW\SHRIUHFRQ-
VWUXFWLRQPRYHVEH\RQGWUDGLWLRQDOV\VWHPVWKDWGR21(7+Ζ1*YHU\ZHOOWRV\VWHPVWKDWDFFRPSOLVK
08/7Ζ3/(REMHFWLYHVVLPXOWDQHRXVO\$&)KDVVHYHUDOWHFKQRORJLHVWKDWGRYHWDLOZLWKWKHJRDOVRI/Ζ'DQG
*ΖWKDWFDQSOD\DVLJQLȴFDQWUROHLQWKHUHGHYHORSPHQWSURFHVV
l
nta
me
iron
Env

SPACE
ACF

EFFICIENT R-TANK®
NS

SUBSURFACE
IO
LUT
SO

STORAGE
WMS
LID

3LSHDQGVWRQHDUHXVHGLQWUDGLWLRQDOV\VWHPVWRPRYHDQGVWRUHUXQR΍
57DQNGRHVWKHVDPHMREEXWZLWKVHYHUDODGGLWLRQDOEHQHȴWV
z SWRUHVDQGPRYHVUXQR΍ z 0RYHVZDWHUVORZO\LQFUHDVLQJWLPHRIFRQFHQWUDWLRQ
 z 2SHQV\VWHPHQFRXUDJHVLQȴOWUDWLRQ z )XOO\DFFHVVLEOHIRUPDLQWHQDQFH
 z 6WRUHVPRUHZDWHUWKDQVWRQH z 0D[LPL]HVVWRUDJHSRWHQWLDORI*ΖSUDFWLFHVOLNH
 z (DVLO\KDQGOHVWUDɝFORDGVEHQHDWKVLGHZDONVDQGVWUHHWV  ELRUHWHQWLRQVWUHHWWUHHSLWVHWF
 z 6KLSVȵDWWRUHGXFHVLWHGLVWXUEDQFH
tal
men

tal
men
ron

ron

VEGETATED/
Envi

FOCALPOINT
RUNOFF
Envi

PERMEABLE PAVEMENTS
ACF

BIOLOGICAL
ACF

REDUCTION
NS

NS

TREATMENT
TIO

TIO

TECHNIQUES
OLU

OLU

SYSTEM
MS

MS
SW

SW
LID

LID

7UDGLWLRQDOODQGVFDSLQJDGGVDHVWKHWLFYDOXHWR 7UDGLWLRQDOSDYHPHQWVPRYHYHKLFOHVHɝFLHQWO\
SURMHFWVEXWKDVPRUHSRWHQWLDO0DQ\GHYHORSHUV EXWDUHHDVLO\GDPDJHGE\VWRUPZDWHU$&)
WXUQWRELRUHWHQWLRQEXWDUHIRUFHGWRVXUUHQGHU VSHFLDOL]HVLQSHUYLRXVSDYHPHQWVWKDWKDQGOH
PDVVLYHODQGDUHDVDQGGHGLFDWHVLJQLȴFDQW WUDɝFHDVLO\ZKLOHSURYLGLQJVXUIDFHLQȴOWUDWLRQ
IXWXUHIXQGVWRPDLQWHQDQFH)RFDO3RLQWUHGXFHV UDWHVWLPHVKLJKHUWKDQWUDGLWLRQDOSHUYLRXV
WKHVSDFHUHTXLUHPHQWVDQGPDLQWHQDQFHFRVWVRI SDYHPHQWV+LJKVXUIDFHLQȴOWUDWLRQUDWHVUHGXFH
ELRUHWHQWLRQE\XSWRZKLOHSURYLGLQJDOOWKH WKHH[SHQVHRIORQJWHUPPDLQWHQDQFHDQGWKH
ZDWHUSXULȴFDWLRQEHQHȴWV KHDGDFKHVWKDWJRZLWKLW
z $GGVDHVWKHWLFYDOXHWRSURSHUWLHV z HaQGOHVDOOYHKLFXODUORDGV
 z &OHDQVUXQR΍WRLPSURYHZDWHUTXDOLW\  z 'UDLQVWHQWLPHVIDVWHUWKDQFRPSHWLQJSHUYLRXV
 z 5HGXFHVVSDFHUHTXLUHPHQWVDQGPDLQWHQDQFHFRVWV SDYHPHQWV
  RIWUDGLWLRQDOELRUHWHQWLRQV\VWHPV  z 5HGXFHVORQJWHUPPDLQWHQDQFHFRVWV
 z (QFRXUDJHVLQȴOWUDWLRQWRUHGXFHYROXPHRIZDWHU  z (QFRXUDJHVLQȴOWUDWLRQ
discharged  z 3DLUZLWK57DQN®WRPD[LPL]HZDWHUVWRUDJHDQG
 z 3DLUZLWK57DQN®WRPD[LPL]HZDWHUVWRUDJHDQG transport
transport 6-12" OF BEDDING STONE
(THICKNESS TO BE
DETERMINED BY ENGINEER) PERVIOUS PAVEMENT (5.65")

R-TANKXD (1.97")

ACF M200 GEOTEXTILE


CROSS-SECTION
57$1. SIDE VIEW
5
MAINTENANCE
'HVLJQLQJDQ57DQN6\VWHPZLWKORQJHYLW\DQGPDLQWH-
QDQFHLQPLQGLVDVLPSOHWKUHHVWHSSURFHVV INLET CONNECTION
BACKFILL COMPACTED TO 95%
GEOGRID STANDARD PROCTOR DENSITY PAVED SURFACE INLET STRUCTURE TYPE AND SIZE

1. PREVENT
TO BE DETERMINED BY ENGINEER
OPTIONAL INLET PIPE

.HHSGHEULVDQGVHGLPHQWRXWRIWKHV\VWHPE\
SUHWUHDWLQJUXQR΍ZLWKWKH7UDVK*XDUG3OXV®XQLW VHH 8 OZ NONWOVEN

EHORZ )RUDPRUHFHQWUDOL]HGDSSURDFK\RXFRXOG
GEOTEXTILE
SUMP DEPTH TO BE
R-TANK UNITS
DETERMINED BY ENGINEER

FRQVLGHUKDYLQJWKH57DQNXQLWVSHQHWUDWHWKHFRQQHFW- 12"

LQJVWUXFWXUHZKLFKDOORZVWKHXVHRIWKH57DQN® as its OPTIONAL OUTLET PIPE

RZQWUDVKVFUHHQ7KLVZRUNVEHVWZLWKDVWUXFWXUHWKDW 24" MIN. 3" MIN. BASE MATERIAL BASE MATERIALS


AS REQUIRED

LQFOXGHVDVXPS VHHGUDZLQJWRULJKW 
SECTION VIEW

2. ISOLATE
7UDSVROLGSROOXWDQWVLQVLGHWKHPDLQWHQDQFHURZ VHH MAINTENANCE ROW
GUDZLQJWRULJKW ZKHUHWKH\FDQEHHDVLO\UHPRYHG
Ø12" MIN. SDR-35 PVC PIPE NOTE: IF PIPE CONNECTING TO
NOTE: MAINTENANCE ROW IS LARGER R-TANKHD MAINTENANCE ROW
W/ BEVELED EDGE OR AS
FOR TRAFFIC RATING COVER REQUIREMENTS, THAN Ø12" SDR-35, IT SHALL BE (SEE PLAN LAYOUT FOR ROW LENGTH)
PAVED OR GRASS SPECIFIED BY PROJECT ENGINEER
SEE APPROPRIATE DETAIL. ABUTTED FLUSH TO END PLATE AND
SURFACE (BY OTHERS) Ø24" F&C ACCESS
SEALED WITH A GEOTEXTILE BOOT.
(TYP, BY OTHERS)

XVLQJWKH0DLQWHQDQFH0RGXOHV DYDLODEOHLQ/'+'
A B A
GEOGRID R-TANKHD MAINTENANCE
(REQUIRED IN AREAS SUBJECT MODULES TOP AND SIDES
OPTIONAL
TO VEHICULAR TRAFFIC LOADS) WRAPPED IN 8 OZ.
MAINTENANCE
NONWOVEN GEOTEXTILE
/ACCESS

DQG8'RQO\ 7KHVHPRGXOHVDUHZUDSSHGLQJHRWH[WLOH
DIVERSION/ACCESS STRUCTURE
12" MIN. STRUCTURE W/ 12" SUMP (BY OTHERS)
(BY OTHERS) Ø12" MIN. SDR-35 PVC PIPE
W/ BEVELED EDGE OR AS

WRUHWDLQVROLGVDQGDUHIXOO\DFFHVVLEOHE\FRQYHQWLRQDO
Ø12" MIN. PIPE OR AS SPECIFIED BY PROJECT ENGINEER
SPECIFIED BY (BY OTHERS)
PROJECT ENGINEER
R-TANKHD
(BY OTHERS)
MAIN DETENTION/RETENTION SYSTEM
(SEE PLANS FOR ACTUAL LAYOUT)

MHWYDFV\VWHPVWRUHPRYHFDSWXUHGSROOXWDQWV
MAINTENANCE PORT
MAINTENANCE PLATE PEAK FLOW JUNCTION (QUANTITY & LOCATIONS
(5 PER MODULE) STRUCTURE B PER PLAN LAYOUT)
(BY OTHERS)
GEOTEXTILES MUST 2'-0" MIN. STONE
EXTEND A MINIMUM 6" PERIMETER R-TANKHD MAINTENANCE ROW WITH PRECAST INLET/ACCESS STRUCTURE
BEYOND MODULES
MODULES TOP AND NON-CORROSIVE
SIDES WRAPPED WITH HOSE CLAMP
R-TANKHD 2 LAYERS OF ACF S300 WOVEN 8 OZ. NONWOVEN

3. PROTECT
MAIN DETENTION/RETENTION SYSTEM GEOTEXTILE TO BE PLACED BETWEEN GEOTEXTILE Ø12" MIN. SDR-35 OR AS SPECIFIED
(SEE PLANS FOR ACTUAL LAYOUT) R-TANK MODULES AND BASE GEOTEXTILE
MAINTENANCE
ROW MODULES PIPE BOOT
R-TANKHD MAINTENANCE ROW SECTION B-B TYPICAL PIPE CONNECTION DETAIL

(QVXUHDORQJV\VWHPOLIHE\LQFOXGLQJPDLQWHQDQFH
GEOGRID (REQUIRED IN TRAFFIC AREAS)
R-TANKHD MAINTENANCE 28.15" 15.75"
DIVERSION/ACCESS 3/$&('´$%29(7+(57$1.୪୦6<67(0
STRUCTURE W/ 12" SUMP PAVED OR GRASS MODULES TOP AND SIDES 29(5/$3$'-$&(173$1(/6%<´0,1
(BY OTHERS) SURFACE WRAPPED IN 8 OZ. GEOGRID SHOULD EXTEND 3' BEYOND THE

17.32"

17.32"
NONWOVEN GEOTEXTILE EXCAVATION FOOTPRINT. SIDE END

SRUWVWRUHPRYHDQ\SROOXWDQWVWKDWHYDGHWKHSUH SEE TRAFFIC LOADING DETAIL


OR GREEN SPACE DETAIL FOR
COVER REQUIREMENTS
OPTIONAL
MAINTENANCE
28.15"
ISOMETRIC

WUHDWPHQWV\VWHPDQGPDLQWHQDQFHURZ0DLQWHQDQFH

15.75"
/ACCESS
TOP
DIVERSION STRUCTURE
WEIR 12" MIN. W/ 12" SUMP
(BY OTHERS)

SRUWVVKRXOGEHVSHFLȴHGZLWKLQȇRILQOHWDQGRXWOHW OUTLET
/BYPASS

FRQQHFWLRQVDQGURXJKO\ȇRQFHQWHU VHHGHWDLORQ
PIPE

MODULE DATA

GEOMETRY: LOAD RATING:

SDJH 
FLOW LENGTH = 28.15 IN. (715 MM) 33.4 PSI, (MODULE ONLY)
WIDTH = 15.75 IN. (400 MM) HS20, (WITH ACF COVER SYSTEM)
HEIGHT = 17.32 IN. (440 MM) MATERIAL:
TANK VOLUME = 4.44 CF 100% RECYCLED POLYPROPYLENE
Ø12" MIN. SDR-35 PVC PIPE STORAGE VOLUME = 4.22 CF SMALL PLATES PER
W/ BEVELED EDGE OR AS VOID INTERNAL VOLUME: 95% SEGMENT/TOTAL:
2 LAYERS OF ACF S300 MAINTENANCE
SPECIFIED BY PROJECT PLATE VOID SURFACE AREA: 90% 5/5
WOVEN GEOTEXTILE TO BE
ENGINEER (TYP.) PLACED BETWEEN R-TANK (5 PER MODULE)
NOTE: DIVERSION WEIR ELEVATION TO BE SET BY PROJECT ENGINEER MODULES AND BASE
BASED ON TREATMENT VOLUME/FLOW RATE REQUIRED. R-TANKHD MAINTENANCE ROW SECTION A-A SINGLE R-TANKHD - MAINTENANCE MODULE DETAIL

MAINTENANCE PREVENTION
TRASH GUARD PLUS ®
7UDVK*XDUG3OXV® LVDSDWHQWHGVWRUPZDWHUSUHWUHDWPHQWGHYLFH
WKDWFDSWXUHVGHEULVVHGLPHQWDQGȵRDWDEOHV(DV\WRLQVWDOODQG
PDLQWDLQLWLVDIUDFWLRQRIWKHFRVWRIRWKHUSUHWUHDWPHQWGHYLFHV

%HQHȴWVRI7UDVK*XDUG3OXV®
 z 6LPSOHUHWURȴWWRH[LVWLQJFDWFKEDVLQV

 z ΖQVWDOOVZLWKRXWKHDY\HTXLSPHQW

 z 4XLFNDQGHDV\DVVHPEO\
 z $GMXVWVWRLUUHJXODUFDWFKEDVLQERWWRPV
  DQGRUZDOOV
 z (OLPLQDWHVH\HVRUHVWRUPZDWHUWUDVK
 DWSXEOLFSDUNVEHDFKHVDQGZDWHUZD\V
 z 5HPRYHVKDUPIXOQXWULHQWVDQGUHJXODWHG
  PHWDOV


TYPICAL DESIGN
CAD DRAWINGS
0RGXOH'UDZLQJ'RXEOH 0DLQWHQDQFH0RGXOH'RXEOH
28.15" 15.75"

28.15" 15.75"
33.86"

33.86"

33.86"

33.86"
SECTION VIEW FRONT VIEW
28.15"

ISOMETRIC VIEW
SIDE END
15.75"

28.15"
ISOMETRIC
PLAN VIEW MODULE DATA

LOAD RATING:
MODULE DATA GEOMETRY: 33.4 PSI, (MODULE ONLY)

15.75"
LENGTH = 28.15 IN. (715 MM) HS20, (WITH ACF COVER SYSTEM)
GEOMETRY: LENGTH = 28.15 IN. (715 MM) LOAD RATING: 33.4 PSI, (MODULE ONLY) WIDTH = 15.75 IN. (400 MM) MATERIAL:
WIDTH = 15.75 IN. (400 MM) HS25, (WITH ACF COVER SYSTEM) HEIGHT = 33.86 IN. (860 MM) 100% RECYCLED
HEIGHT = 33.86 IN. (860 MM) TANK VOLUME = 8.69 CF POLYPROPYLENE
TANK VOLUME = 8.69 CF MATERIAL: 100% RECYCLED STORAGE VOLUME = 8.25 CF SMALL PLATES PER
STORAGE VOLUME = 8.25 CF POLYPROPYLENE VOID INTERNAL VOLUME: 95% SEGMENT/TOTAL:
VOID INTERNAL VOLUME: 95% SMALL PLATES PER VOID SURFACE AREA: 90% 5/10
VOID SURFACE AREA: 90% SEGMENT/TOTAL: 5/10 TOP

&RPSRVLWH'HWDLOV 0DLQWHQDQFH3RUW
16.25" FRAME AND
BACKFILL COMPACTED TO COVER
REINFORCED
95% STANDARD PROCTOR 12" DIA. PVC CONCRETE COLLAR
DENSITY MAINTENANCE
NOTES WHERE REQUIRED
PORT
TOTAL COVER: 20” MINIMUM AND 84” MAXIMUM. FIRST 12” MUST BE
x THIS PORT IS USED TO PUMP WATER INTO THE SYSTEM PAVED SURFACE
NOTES:
FREE DRAINING BACKFILL (SPEC SECTION 2.03B): STONE <1.5” OR SOIL
(USCS CLASS GW, GP, SW OR SP). ADDITIONAL FILL MAY BE
STRUCTURAL FILL (SPEC SECTION 2.03C): STONE OR SOIL (USCS
1. FOR COMPLETE MODULE DATA, SEE APPROPRIATE R-TANK୪୦MODULE SHEET .
2. INSTALLATIONS PER THIS DETAIL MEET GUIDELINES OF HL-93 LOADING PER THE AASHTO LRFD
16.25" FRAME AND
COVER
REINFORCED
AND RE-SUSPEND ACCUMULATED SEDIMENT SO THAT IT
BRIDGE DESIGN SPECIFICATIONS, CUSTOMARY U.S. UNITS, 7TH EDITION, 2014 WITH 2015 AND 2016 12" DIA. PVC
CLASS SM, SP, SW, GM, GP OR GW) WITH MAX CLAY CONTENT<10%,
MAX 25% PASSING NO. 200 SIEVE, AND MAX PLASTICITY INDEX OF 4. A
INTERIM REVISIONS.
3. PRE-TREATMENT STRUCTURES NOT SHOWN.
BACKFILL COMPACTED TO
95% STANDARD PROCTOR
MAINTENANCE
PORT
CONCRETE COLLAR
WHERE REQUIRED MAY BE PUMPED OUT.
x
MIN. 12” COVER MUST BE MAINTAINED BETWEEN BACKFILL 4. FOR INFILTRATION APPLICATIONS, GEOTEXTILE ENVELOPING R-TANK SHALL BE ACF M200 (PER DENSITY PAVED SURFACE
EQUIPMENT AND THE TOP OF THE R-TANK™ SYSTEM AT ALL TIMES.
TOTAL HEIGHT OF TOP BACKFILL SHOULD NOT EXCEED 7'. CONTACT
SPEC SECTION 2.02A) AND BASE SHALL BE 4" MIN. UNCOMPACTED FREE DRAINING BACKFILL (SPEC
SECTION 2.03A) TO PROVIDE A LEVEL BASE. SURFACE MUST BE SMOOTH, FREE OF LUMPS OR
NOTES
x THIS PORT IS USED TO PUMP WATER INTO THE SYSTEM
AND RE-SUSPEND ACCUMULATED SEDIMENT SO THAT IT
MINIMUM REQUIRED MAINTENANCE INCLUDES A GEOGRID
ACF ENVIRONMENTAL IF MORE THAN 7' OR LESS THAN 20" OF TOP GEOGRID
DEBRIS, AND EXTEND 2' BEYOND R-TANK୪୦ FOOTPRINT. MAY BE PUMPED OUT.
BACKFILL IS REQUIRED (FROM TOP OF TANK TO TOP OF PAVEMENT).
x MINIMUM REQUIRED MAINTENANCE INCLUDES A 24" TYP.
QUARTERLY INSPECTION DURING THE FIRST YEAR OF
GEOGRID (TENSAR BX-1200 OR EQUAL) PLACED 12” ABOVE THE
R-TANK୪୦ SYSTEM. OVERLAP ADJACENT PANELS BY 18” MIN.
QUARTERLY INSPECTION DURING THE FIRST YEAR OF
OPERATION AND A YEARLY INSPECTION THEREAFTER.
18" MIN.
A
PAVED
GEOGRID SHOULD EXTEND 3' BEYOND THE EXCAVATION FOOTPRINT.
36" (0.91 m) MIN. x
FLUSH AS NEEDED.
ONLY R-TANK୪୦ AND R-TANKSD MAY BE USED IN TRAFFIC
12"
NON-CORROSIVE HOSE CLAMP
1" +/- VENTING PERFORATIONS
OPERATION AND A YEARLY INSPECTION THEREAFTER.
UTILITY MARKERS AT COVER FROM FINISH APPLICATIONS. GEOTEXTILE
CORNERS (TYP.)
SURFACE
GRADE TO TOP OF TANK:
20" (0.51 m) MIN.
FLUSH AS NEEDED.
x ONLY R-TANK୪୦ AND R-TANKSD MAY BE USED IN TRAFFIC
84" (2.13 m) MAX.

12" (0.30 m)
OPTIONAL TYPE
DEPTH SUMMARY
A B APPLICATIONS. NON-CORROSIVE HOSE CLAMP
OVERFLOW

INLET PIPE
PIPE R-TANK 12" MIN - 36" MAX
AS SHOWN
ON PLANS
B 1" +/- VENTING PERFORATIONS
R-TANK୪୦ 20" MIN - 6.99' MAX 12"

OPTIONAL R-TANKSD 18" MIN - 9.99' MAX 12" GEOTEXTILE


OUTLET
PIPE

3" (0.08 m) MIN.

24" (0.61 m)
1.5" R-TANK
8" NOTCHES CUT IN SHADED

R-TANK୪୦ UNITS WRAPPED IN 8 OZ.


NONWOVEN GEOTEXTILE (OR EQUAL) BASE: 3” MIN. BEDDING MATERIAL (SPEC SECTION SIDE BACKFILL: 24" MIN. OF FREE DRAINING
AREAS (8 OPENINGS TOTAL)
(REGULAR SHOWN)
LOAD RATING: 33.4 PSI (MODULE ONLY) 2.03A) MAY BE STONE (<1.5”) OR SOIL (USCS CLASS GW, BACKFILL (SPEC SECTION 2.03B): STONE <1.5”
GP, SW OR SP). MUST BE FREE OF LUMPS AND DEBRIS, OR SOIL (USCS CLASS GW, GP, SW OR SP).
SUBGRADE / EXCAVATION LINE: COMPACT PER AND EXTEND 2' BEYOND R-TANKHD. COMPACT PER MUST BE FREE FROM LUMPS, DEBRIS AND
SPEC SECTION 3.02 D. A BEARING CAPACITY SPEC SECTION 3.03 A. NATIVE SOILS MAY BE USED IF OTHER SHARP OBJECTS. SPREAD EVENLY TO NOTCH BOTTOM
OF 2,000 PSF MUST BE ACHIEVED PRIOR TO NON-CORROSIVE
THEY MEET THE REQUIREMENTS OF SPEC SECTION 35(9(1757$1.୪୦029(0(17&203$&7 OF PIPE
INSTALLING R-TANKHD 2.03A AND ARE ACCEPTED BY OWNER'S ENGINEER. SIDE BACKFILL WITH POWERED MECHANICAL
3.5" SOLID PLATE
SEE PATTERN
PLASTIC, SLATE
COMPACTOR IN 12" LIFTS (PER SPEC SECTION
3.05 A2).
PIPE NOTCHING
PATTERN
OR EQUIVALENT
DEPTH SUMMARY
1 2 3 TYPE A B
R-TANK - MODULE DETAIL 57$1.୪୦ & H-20 LOADS - SECTION VIEW R-TANK୪୦ TYPICAL MAINTENANCE PORT
AS SHOWN
2.00 SPACING REF.
Ø0.38 TYP.
R-TANK 12" MIN - 36" MAX ON PLANS
B
1.00 TYP.
END VIEW OF PIPE/FABRIC CONNECTION.

R-TANK୪୦
CUT AN "X" IN THE FABRIC SLIGHTLY
LARGER THAN PIPE, PULL THE FABRIC
AROUND THE PIPE TO CREATE THE "BOOT"
NON-CORROSIVE HOSE
CLAMP OR TAPE USED TO
20" MIN - 6.99' MAX 12"
AND THEN SECURE WITH A HOSE-CLAMP. FASTEN FABRIC TO PIPES 30 MIL PVC LINER Ø0.38 TYP.
TO PREVENT BACKFILL FABRIC OVER ACF
FROM ENTERING PIPE R-TANK୪୦
STRUCTURE
STAINLESS STEEL
BANDS NOTE: CUT FABRIC AND WRAP 1 SPACING REF.
R-TANKSD 18" MIN - 9.99' MAX 12"
GEOTEXTILE FABRIC AROUND PIPE SO THAT PIPE BUTS
OVER ACF R-TANK୪୦ ',5(&7/<$*$,167$&)57$1.୪୦
PIPE EFFLUENT SHALL NOT PASS A
THROUGH FABRIC

SECTION

5.0'

"X" CUT IN THE INLET/OUTLET


FABRIC TO PIPE 2'-0"
ALLOW
PIPE/TANK GEOTEXTILE 2.00
Ø0.38 TYP.
FABRIC
1.5"
± 5.0'̅

INTERFACE
PIPE
O.D.

PIPE 2.00
O.D.
5.00 Ø0.75 TYP.

GEOTEXTILE FABRIC x 30 MIL GEOTEXTILE LINER FABRIC COLLAR TO


8" NOTCHES CUT IN SHADED
OVER ACF R-TANK୪୦ FIT OUTSIDE DIAMETER OF INLET/OUTLET PIPE
x ̅ TRIM AS NEEDED
STAINLESS
STEEL BANDS
SIZE
23" x 24"
A
23"
B
26.51"
AREAS (8 OPENINGS TOTAL)
NON-CORROSIVE HOSE 28" x 30" 28" 33.15"
6.49 REF.
CLAMP OR TAPE USED TO 34" x 36" 34" 38.69"
FASTEN FABRIC TO PIPES
TO PREVENT BACKFILL SIDE VIEW FRONT VIEW ±0.25" TOLERANCE ON DIMENSIONS
FROM ENTERING
STRUCTURE

4 5 6
R-TANK୪୦ TYPICAL TANK INLET/OUTLET DETAIL *(27(;7,/(3,3(%227)2557$1.୪୦ TRASH GUARD PLUS DETAIL

NOTCH BOTTOM
NON-CORROSIVE
OF PIPE
3.5" SOLID PLATE
SEE PATTERN
PLASTIC, SLATE
PIPE NOTCHING OR EQUIVALENT
PATTERN

Selecting the Right R-Tank Module


Module

Cover Depth* (Inches) LD HD SD UD XD


Minimum 6" Green Space - No Traffic Green Space - No Traffic Green Space - No Traffic Green Space - No Traffic HS-20
12" Green Space - No Traffic Green Space - No Traffic Green Space - No Traffic HS-20** HS-20
14" Green Space - No Traffic Green Space - No Traffic Green Space - No Traffic HS-20 HS-20
18" Green Space - No Traffic Green Space - No Traffic HS-20 HS-20 HS-20
20" Green Space - No Traffic HS-20 HS-20 HS-20 HS-20
24" Green Space - No Traffic HS-20 HS-20 HS-20 HS-20
36" Green Space - No Traffic HS-20 HS-20 HS-20 HS-20
48" - HS-20 HS-20 HS-20 HS-20
60" - HS-20 HS-20 HS-20 HS-20
72" - HS-20 HS-20 - HS-20
84" - - HS-20 - HS-20
120" - - HS-20 - HS-20
160" - - - - HS-20
Maximum 200" - - - - HS-20
HS-20 designation based on AASHTO LRFD Bridge Design Specification for Single Lane Traffic
* Cover depth is measured from the top of the module to the finished grade or top of pavement.
** The UD module requires STONE backfill (not soils) on the sides at this depth.


PRODUCT SPECIFICATION

Dimensions & Capacity Dimensions & Capacity


Module Width Length Height Volume Capacity Weight* Module Width Length Height Volume Capacity Weight
(Segments) (inch) (inch) (in/ft) (cf) (cf) (lbs) (Segments) (inch) (inch) (in/ft) (cf) (cf) (lbs)
Mini 15.75 28.15 9.45”/0.79’ 2.42 2.30 10.1/10.9 Single (1) 15.75 28.15 9.45”/0.79’ 2.42 2.30 10.95
Single(1) 15.75 28.15 17.32”/1.44’ 4.44 4.22 15.7/17.3 Double (2) 15.75 28.15 18.12”/1.51’ 4.64 4.41 19.58
Single + Mini(1.5) 15.75 28.15 25.98”/2.17’ 6.67 6.33 23.6/25.9 Triple (3) 15.75 28.15 26.79”/2.23’ 6.86 6.52 28.21
Double (2) 15.75 28.15 33.86”/2.82’ 8.69 8.25 29.1/32.3 Quad (4) 15.75 28.15 35.46”/2.96’ 9.08 8.63 36.84
Double + Mini(2.5) 15.75 28.15 42.52”/3.54’ 10.91 10.36 37.0/41.0 Pent (5) 15.75 28.15 44.13”/3.68’ 11.30 10.74 45.47
Triple (3) 15.75 28.15 50.39”/4.20’ 12.93 12.28 42.5/47.4 Hex (6) 15.75 28.15 52.80”/4.40’ 13.52 12.84 54.10
Triple + Mini(3.5) 15.75 28.15 59.06”/4.92’ 15.15 14.39 50.4/56.0 Septa (7) 15.75 28.15 61.47”/5.12’ 15.74 14.95 62.73
Quad(4) 15.75 28.15 66.93”/5.58’ 17.17 16.31 55.9/62.4 Octo (8) 15.75 28.15 70.14”/5.85’ 17.96 17.06 71.36
Quad + Mini(4.5) 15.75 28.15 75.59”/6.30’ 19.39 18.42 63.8/71.0 Nono (9) 15.75 28.15 78.81”/6.57’ 20.18 19.17 79.99
Pent(5) 15.75 28.15 83.46”/6.96’ 21.41 20.34 69.3/77.4 Decka (10) 15.75 28.15 87.48”/7.29’ 22.40 21.28 88.62
*Weights shown are for LD/HD modules.

Dimensions & Capacity


Module
(Segments)
QHHGUHYLVHG
Width
(inch)
Length
(inch)
Height
(in/ft)
Volume
(cf)
Capacity
(cf)
Weight
(lbs)
Dimensions & Capacity
Module
(Segments)
Width
(inch)
Length
(inch)
Height
(inch)
Volume
(cf)
Capacity
(cf)
Weight
(lbs)
Single (1) 23.62 23.62 14.17”/1.18’ 4.57 4.35 21.2 Single (1) 19.68 23.62 1.97 0.53 0.48 4
Double (2)
Triple (3)
Quad (4)
copy
23.62
23.62
23.62
23.62
23.62
23.62
27.17”/2.26’
40.16”/ 3.35’
53.15”/4.43’
8.77
12.97
17.16
8.33
12.32
16.30
39.0
56.8
74.6
Double (2)
Triple (3)
Quad (4)
19.68
19.68
19.68
23.62
23.62
23.62
3.94
5.91
7.87
1.06
1.59
2.12
0.95
1.43
1.91
8
12
16
Pent (5) 23.62 23.62 66.14”/5.5’ 21.35 20.29 92.4 Pent (5) 19.68 23.62 9.84 2.65 2.38 20

Note: XD modules may be stacked up to 10’ tall (60 layers).

Specifications
Item Description
Void Area Volume available for water storage 95% 95% 95% 95% 90%

Surface Area Void % of exterior available for infiltration 90% 90% 90% 90% 90%

Compressive Strength ASTM D2412 / ASTM F2418 30.0psi 33.4 42.9 psi 134.2 psi 240.2 psi

Unit Weight Weight of plastic/cubic foot of tank 3.29 lbs/cf 3.62 lbs/cf 3.96 lbs/cf 4.33 lbs/cf 7.55 lbs/cf

Rib Thickness Thickness of load-bearing members 0.18 inches 0.18 inches 0.18 inches - -

Service Temperature Safe temperature range for use -14 - 167϶ F -14 - 167ͼ F -14 - 167ͼ F -14 - 167ͼ F -14 - 167ͼ F

Recycled Content Use of recycle polypropylene 100% 100% 100% 100% 100%

Minimum Cover Cover required for HS-20 loading 1RW7UDIILF5DWHG 20" 18" 12" 6"

Minimum Cover Cover required for HS-25 loading 1RW7UDIILF5DWHG 24" 18" 15" 6"

Maximum Cover Maximum allowable cover depth 3.0' 6.99' 9.99' 5.0' 16.7'

You might also like