PRODUCTS
Circuit Breakers
March 16, 2012
City of Ocala
Resource Management
th
1805 NE 30 Avenue
Building “400”-Gate 1
Ocala, FL 34470
Attn: Ms. Jane Hurley
ALSTOM is a leading manufacturer of high voltage circuit breakers and circuit switchers with R&D and manufacturing facilities
located in Charleroi, Pennsylvania. Our facility is an ALSTOM Center of Excellence for research and development, testing, and
manufacturing of dead tank circuit breakers for worldwide distribution and is certified to ISO9001-2008, ISO1400-2004 and
OHSAS18001-2007.
Our Charleroi, PA campus includes a fully functional research & development facility with a staff of over 20 engineers and
technicians dedicated to product development. This local development team ensures that new products are designed to meet the
rigorous demands of the US power system. The ALSTOM team also includes worldwide development with R&D centers in Kassel,
Germany and Villeurbanne, France. We have currently delivered nearly 15,000 circuit breakers from this factory since 1993.
The ALSTOM line of circuit breakers and circuit switchers are developed with a family approach. Common components such as
mechanisms and interrupters are shared between the dead tank and circuit switcher products providing a reduction in cost of
ownership. Furthermore, our breakers and switchers are tested to ensure significant Close-Open mechanical operations without
maintenance.
ALSTOM stands ready to serve you. Our uniquely qualified team includes industry leaders with decades of experience in the
transmission and distribution world as well as the high voltage circuit breaker industry. The members of the ALSTOM team are
available at any time and are dedicated together with our Charleroi staff of nearly 200 employees to providing you best in industry
service and support.
Regards,
William J. Floder Soman Varghese Perry Webster
Regional Product Manager ALSTOM Area Manager Electric Sales Associates, Inc
william.floder@Alstom.com soman.varghese@Alstom.com perryw@electricsalesinc.com
724-483-7866 678-920-2709 954-385-3266
Alstom Grid, Inc.
One Power Lane
Charleroi, PA 15022
Phone: 724-483-7308
Fax: 724-483-7771
www.alstom.com
SECTION 00-400
PROPOSAL AND BID FORM
SECTION 00-400
PROPOSAL AND BID FORM
Submit one (1) original and one CD (PDF format) electronic version.
1. Proposal
Pursuant to and in compliance with your Invitation to Bid dated February 17, 2012, the Instructions to Bidders
and other documents relating thereto, the undersigned proposes to furnish and install the following equipment at
the City of Ocala, Florida, at the prices listed below and within the times specified herein by the City of Ocala,
and based on the description of Bid Item Numbers contained in Section 00-400.
8
SECTION 00-400
PROPOSAL AND BID FORM
Unit of
Item Qty Description Unit Price Total Price
Measure
Circuit Breaker, High Voltage, Outdoor,
15kV Class, 1200 Amp, with Relaying.
2 5 Each Complete with required accessories. $ $
Complete requirements outlined in Sections
16-010 and 16-014.
Recommended Circuit Breaker Spare Parts
2a 1 Lot $ $
Total.
SUBTOTAL $
Note: The above prices do not include Florida State Sales Tax, which is not applicable.
Will you hold your FY’12 bid price for FY’13 breakers?
X Yes
______ No (indicate below any expected price escalation/de-escalation and the formula you would use to determine
same)
9
SECTION 00-400
PROPOSAL AND BID FORM
Will you hold your FY’12 bid price for FY’14 breakers?
X Yes
______ No (indicate below any expected price escalation/de-escalation and the formula you would use to determine
same)
Any FY’13 and/or FY’14 purchases must be mutually agreed upon by both the City of Ocala and awardee.
By submitting a bid, the bidder hereby certifies that the company submitting the bid is in compliance
with all of the requirements of Department of Homeland Security’s E-Verify System for the duration of
the contract entered into between the City of Ocala and the Company or Organization OR will hire no
employees for the term of the contract between the City of Ocala and the Company or Organization.
http://www.uscis.gov/e-verify
10
SECTION 00-400
PROPOSAL AND BID FORM
2. Discount Schedule
A discount in the amount indicated will be allowed if payment is made within the number of days stated from date
of invoice or date of delivery and acceptance, whichever is later.
3. Manufacturer
If a bid is submitted for Items 1, Appendix 1 has been completed with pertinent information and is attached to this
proposal.
If a bid is submitted for Item 2, Appendix 2 has been completed with pertinent information and is attached to this
proposal.
Where spare parts are recommended, an itemized listing is attached to this Proposal, including description, part
number, recommended quantity and price.
A. If awarded a contract as a result of this proposal, the subcontractor used in the prosecution of the work will be
those listed below. OUS reserves the right to reject any subcontractor or specific employee, based on previous
experience with said subcontractor or employee, without financial impact to OUS. Bidders are strongly
encouraged to provide names of engineers and construction foremen in order to prevent rejection after the bid
award.
11
SECTION 00-400
PROPOSAL AND BID FORM
B. The bidder represents that the subcontractors listed below are financially responsible and are qualified to do
the work required.
Hauling
Ocala Utility Services requires Delivery of equipment, as defined in Section 00-710, Paragraph 2, within the
following dates:
1. Circuit Breaker, 69 KV, 1200 Amp September 1, 2012 September 30, 2012
2. Circuit Breaker, 15 KV, 1200 Amp September 1, 2012 September 30, 2012
12
SECTION 00-400
PROPOSAL AND BID FORM
The Bidder proposes to complete Delivery of Items, as listed below, including an allowance for review of shop
drawings (see Section 00-810, Part 3, Paragraph D). The bidder understands proposed delivery times longer than
stated above may be grounds for rejection of bid.
Delivery dates are based on a Conditional Notice of Award and Conditional Notice to Proceed of April 4, 2012. A
Conditional Notice of Award of Contract and Conditional Notice to Proceed are conditioned only by the
requirement that the Contractor shall deliver acceptable bond(s), proof(s) of insurance, and related documents,
properly executed on behalf of the Contractor, and to otherwise demonstrate his fitness, willingness and ability to
enter into the contract as described herein. Failure to issue Conditional Notice of Award, Conditional Notice to
Proceed by the date indicated shall constitute basis for a day-for-day extension in the proposed delivery schedule.
Conditional Notice of Award may or may not include the Conditional Notice to Proceed with the Contract. If the
Conditional Notice to Proceed is separated from the Conditional Notice of Award, completion time shall be
extended on a day-for-day basis to allow for elapsed time between Conditional Notice of Award and Conditional
Notice to Proceed.
7. Delivery to Be Made To
1. Three (3) Circuit Breakers 69 KV, 1200 Amp shall be delivered to the Utility Services Warehouse.
2. Five (5) Circuit Breakers 15 KV, 1200 Amp shall be delivered to the Utility Services Warehouse
The Bidder agrees to deliver equipment to the Utility Services Warehouse at 1805 NE 30th Ave, Bldg 700, Gate
#5, Ocala Florida 34470. Access requirements shall be established by on-site investigation by the Bidder.
Delivery shall be completed between the hours of 7:30 a.m. and 12:00 noon, or 1:00 p.m. and 3:30 p.m. Local
Time, Monday through Friday, but shall not be made on legal holidays and with a 48-hour notice prior to
delivery.
8. Bidder Agreement
* The Bidder shall strike out the word(s) which do not apply.
In the event the items covered by this quotation (including any modification or alternative) are not as specified, a
full description is attached to the quotation describing the item (modification or alternative) on which the
quotation is made, specifically noting exceptions to the specifications. The Bidder understands that failure to
13
March 16, 2012 FL-USC-12449/1 Page 6
Note:
This offer is subject to mutually agreed upon Terms & Conditions between City of Ocala and ALSTOM Grid, Inc. dated 02/27/2009. Please
refer to the attached Terms & Conditions.
References:
Address:
Project Description:
Address:
Project Description:
Address:
Project Description:
Address:
Project Description:
18
SECTION 00-400
PROPOSAL AND BID FORM
Address:
Project Description:
Facility has 87,000 square feet. Alstom is currently expanding the facility
to 100,000 square feet.
19
GRID
PRODUCTS
Circuit Breakers
CONTACTS
COMPANY CONTACT ADDRESS PHONE RATINGS
IF YOU DO NOT INTEND TO BID ON THIS REQUIREMENT, PLEASE COMPLETE AND RETURN THIS FORM
PRIOR TO DATE SHOWN FOR RECEIPT OF BIDS TO: CITY OF OCALA UTILITY SERVICES, PURCHASING DIVISION,
1805 NE 30TH AVENUE, BLDG 400, GATE 1, OCALA, FLORIDA 34470.
WE, THE UNDERSIGNED, HAVE DECLINED TO BID ON YOUR BID NO. ITB 12-037 OPENING March 16, 2012,
FOR FOR THE FOLLOWING REASON(S):
REMARKS:
WE UNDERSTAND THAT IF THIS "NO BID" LETTER IS NOT EXECUTED AND RETURNED, OUR NAME MAY BE
DELETED FROM THE LIST OF QUALIFIED BIDDER'S FOR THE CITY OF OCALA FOR FUTURE PROJECTS OR
COMMODITIES.
COMPANY NAME
ADDRESS
20
SECTION 00-400
PROPOSAL AND BID FORM
Under penalty of perjury, the undersigned states that the forgoing statements are true and correct. The undersigned also
acknowledges that any person, firm, corporation or entity intentionally submitting false information in an attempt to
qualify for local vendor preference shall be prohibited from bidding on City of Ocala products and services in accordance
with CP-161 of the City of Ocala’s Purchasing and Procedures manual.
21
SECTION 00-400
PROPOSAL AND BID FORM
APPENDIX 1
69KV – 1200 AMP
SECTION 00-400
PROPOSAL AND BID FORM - APPENDIX 1 - 69KV - 1200AMP
SHEET 1 of 2
22
SECTION 00-400
PROPOSAL AND BID FORM
APPENDIX 1
69KV – 1200 AMP
SECTION 00-400
PROPOSAL AND BID FORM - APPENDIX 1 - 69KV - 1200AMP
SHEET 2 of 2
Total: $ 635.-USD
23
SECTION 00-400
PROPOSAL AND BID FORM
APPENDIX 2
15KV – 1200 AMP
SECTION 00-400
PROPOSAL AND BID FORM - APPENDIX 2 - 15KV - 1200AMP
SHEET 1 of 2
Manufacturer
Model/Type/Design
24
SECTION 00-400
PROPOSAL AND BID FORM
APPENDIX 2
15KV – 1200 AMP
No Quote
Bushing Manufacturer
Total: $
END OF SECTION
25
SECTION 00-430
BID BOND
SECTION 00-430
BID BOND
for the payment of which, well and truly to be made, we hereby jointly and severally bind ourselves, our heirs, executors,
The condition of the above obligation is such that whereas the Principal has submitted to
a certain Bid, attached hereto and hereby made a part hereof to enter into
NOW, THEREFORE,
(b) If said Bid shall be accepted and the Principal shall execute and deliver a contract in the form of the Construction
Agreement attached hereto (properly completed in accordance with said Bid) and shall furnish a bond for his faithful
performance of said contract and for the payment of all persons performing labor or furnishing materials in
connection therewith, and shall in all other respects perform the agreement created by the acceptance of said Bid,
then this obligation shall be void, otherwise the same shall remain in force and effect; it being expressly understood and agreed that
the liability of the Surety for any and all claims hereunder shall, in no event, exceed the penal amount of this obligation as herein
stated.
The Surety, for value received, hereby stipulates and agrees that the obligations of said Surety and its bond shall be in no way
impaired or affected by an extension of the time within which the Owner may accept such Bid; and said Surety does hereby waive
notice of any such extension.
26
SECTION 00-430
BID BOND
IN WITNESS WHEREOF, the Principal and the Surety have hereunto set their hands and seals, and such of them as are
corporations have caused their corporate seals to be hereto affixed and these presents to be signed by their proper officers,
the day and year first set forth above.
(L.S.)
Principal
Surety
By
SEAL
END OF SECTION
27
SECTION 00-610
PERFORMANCE AND PAYMENT BOND
SECTION 00-610
PERFORMANCE AND PAYMENT BOND
STATE OF FLORIDA
COUNTY OF MARION
CITY OF OCALA
THE CONDITION OF THE OBLIGATION IS SUCH, that whereas the Principal on the day of , 20 , entered
into a certain Contract with the City, hereto attached, for Contract entitled __________________________ - BID NO. _________,
City of Ocala, Florida.
NOW, THEREFORE, if the Principal shall well and truly perform and fulfill all the undertakings, covenants, terms, conditions,
and agreements of said Contract and shall well and truly perform and fulfill all the undertakings, covenants, terms, conditions and
agreements of any and all fully authorized modifications of said Contract that may hereafter be made, notice of which modifications to
the Surety being hereby waived;
AND FURTHERMORE, if the Principal shall promptly make payment to all claimants, as defined in Section 255.05 (1),
Florida Statutes supplying Principal with labor, materials, or supplies, used directly or indirectly by Principal in the prosecution of the
work provided for in said Contract that may hereafter be made, notice of which modifications to the Surety being hereby waived, then
this obligation shall be void; otherwise it shall remain in full force and effect.
As provided in Section 255.05(2), Florida Statutes, a claimant, except a laborer, who is not in privity with the Principal and
who has not received payment for his labor, materials, or supplies shall, within forty-five (45) days after beginning to furnish labor,
materials, or supplies for the prosecution of the work, furnish the Principal with a notice that he intends to look to this Bond for
protection. A claimant who is not in privity with the Principal and who has not received payment for his labor, materials, or supplies
shall, within ninety (90) days after performance of the labor or after complete delivery of the materials or supplies, deliver to the
Principal and the surety written notice of the performance of the labor or delivery of the materials of supplies and of the nonpayment.
No action for the labor, materials, or supplies may be instituted against the Principal or the Surety unless both notices have been given.
No action shall be instituted against the Principal or the Surety on this Bond after one (1) year from the performance of the labor or
completion of delivery of the materials or supplies.
THIS BOND shall be security for the performance by the Principal and Surety of the following additional covenants and
obligations, and the recitals and references herein contained shall constitute a part of this Bond and obligation:
1. Each and every person, natural and artificial, for whose benefit this Bond has been executed, as disclosed by the text of this
Bond and of said Contract, Specifications and Plans, and of said Agreement, and instruments attached together and made a part
of the said Contract, shall have the same several rights of suit of action upon this bond as if he or they were the City herein
specifically mentioned, and the obligations hereof shall be several as to the rights of said persons of the City.
2. In each and every suit brought against the Principal and Surety upon this bond in which the Plaintiff shall be successful, there
shall be assessed therein against the Principal and Surety herein, in favor of the Plaintiff therein, reasonable counsel fees and all
costs and expenses incurred by the plaintiff which the Principal and surety hereby expressly agree to pay as part of the cost and
expenses of such suit.
3. In case of annulment of the Contract, as provided in the Specifications, there shall be assessed against the Principal and Surety
herein, all expenses, including engineering and legal services, incident to collecting losses to the City under this Bond.
30
SECTION 00-610
PERFORMANCE AND PAYMENT BOND
IN WITNESS WHEREOF, the above bounded parties have executed this instrument under their several seals on the date indicated
above, the name and corporate seals of each corporate party being hereto affixed and these Presents duly signed by its undersigned
representatives, pursuant to authority of its governing body.
By
Pres., V. Pres., etc. – Sign name
Attest: (SEAL)
(SEAL)
By
NOTE: If both Principal and Surety are a corporation, the respective corporate seals should be affixed.
As the person authorized to sign the statement, I certify that this firm complies fully with the above requirements.
END OF SECTION
31
March 16, 2012 FL-USC-12449/1 Page 2
Item 1 FY-12
Three (3) 72.5 kV Dead Tank Circuit Breakers according to ANSI/IEEE standards for outdoor installation with mechanical spring
operating mechanisms including support structures.
Type DT1-72.5 F1 FK
Rated nominal Voltage 69 kV
Rated maximum Voltage 72.5 kV
Frequency 60 Hz
Rated continuous current 1200 A
Rated short-circuit current 31.5 kA*
BIL 350 kV
Creep Distance / Material / Color 74” / Porcelain / Gray
Insulating medium SF6
Interrupting time 3 cycles
High-speed auto-reclosure 3 phase, gang operated
Current transformers (12) 1200:5 MR C400, TRF 2.0
Cabinet Enclosure Rating / Material NEMA 3R / Painted Steel
Ambient temperature -30°C to +50°C without tank heaters
Seismic Rating Per IEEE / Low
Altitude ≤ 3,300’ ASL
Control Voltage 48 VDC or as Specified
Motor Voltage 240 VAC or as Specified
Alternate current circuit (lighting/heating): 120/240 VAC
Notes
* The X/R rating of the DT1-72.5 is 32 at 40kA. This breaker may be nameplated for up to 45kA interrupting current with a
standard X/R=17. This provides significant performance margin and ensures that the circuit breaker will perform at the
highest level with less maintenance.
The DT1-72.5 is qualified to M2 class for mechanical endurance in accordance with IEC 62271-100. This rating qualifies the
DT1-72.5 mechanically for 10,000 Close-Open operations without maintenance.
The DT1-72.5 is qualified to C2 class for capacitor switching in accordance with IEC 62271-100. This rating qualifies the DT1-
72.5 for switching of capacitive loads with very low probability of re-strike.
The foundation layout dimensions of the DT1-72.5 are 40.5” x 40.5”, allowing for simplified installation for new construction
as well as OCB replacement.
State of the art proprietary bushing sealing system improves SF6 gas tightness.
Porcelain Bushings are tested for high pollution environments using the salt-fog method.
ALSTOM has delivered over 6,500 DT1-72.5 circuit breakers since 1993.
Item 2 FY-13
Two (2) 72.5 kV Dead Tank Circuit Breakers according to ANSI/IEEE standards for outdoor installation with mechanical spring
operating mechanisms including support structures.
Type DT1-72.5 F1 FK
Rated nominal Voltage 69 kV
Rated maximum Voltage 72.5 kV
Frequency 60 Hz
Rated continuous current 1200 A
Rated short-circuit current 31.5 kA*
BIL 350 kV
Creep Distance / Material / Color 74” / Porcelain / Gray
Insulating medium SF6
Interrupting time 3 cycles
High-speed auto-reclosure 3 phase, gang operated
Current transformers (12) 1200:5 MR C400, TRF 2.0
Cabinet Enclosure Rating / Material NEMA 3R / Painted Steel
Ambient temperature -30°C to +50°C without tank heaters
Seismic Rating Per IEEE / Low
Altitude ≤ 3,300’ ASL
Control Voltage 48 VDC or as Specified
Motor Voltage 240 VAC or as Specified
Alternate current circuit (lighting/heating): 120/240 VAC
Notes
* The X/R rating of the DT1-72.5 is 32 at 40kA. This breaker may be nameplated for up to 45kA interrupting current with a
standard X/R=17. This provides significant performance margin and ensures that the circuit breaker will perform at the
highest level with less maintenance.
The DT1-72.5 is qualified to M2 class for mechanical endurance in accordance with IEC 62271-100. This rating qualifies the
DT1-72.5 mechanically for 10,000 Close-Open operations without maintenance.
The DT1-72.5 is qualified to C2 class for capacitor switching in accordance with IEC 62271-100. This rating qualifies the DT1-
72.5 for switching of capacitive loads with very low probability of re-strike.
The foundation layout dimensions of the DT1-72.5 are 40.5” x 40.5”, allowing for simplified installation for new construction
as well as OCB replacement.
State of the art proprietary bushing sealing system improves SF6 gas tightness.
Porcelain Bushings are tested for high pollution environments using the salt-fog method.
ALSTOM has delivered over 6,500 DT1-72.5 circuit breakers since 1993.
Item 3 FY-14
Two (2) 72.5 kV Dead Tank Circuit Breakers according to ANSI/IEEE standards for outdoor installation with mechanical spring
operating mechanisms including support structures.
Type DT1-72.5 F1 FK
Rated nominal Voltage 69 kV
Rated maximum Voltage 72.5 kV
Frequency 60 Hz
Rated continuous current 1200 A
Rated short-circuit current 31.5 kA*
BIL 350 kV
Creep Distance / Material / Color 74” / Porcelain / Gray
Insulating medium SF6
Interrupting time 3 cycles
High-speed auto-reclosure 3 phase, gang operated
Current transformers (12) 1200:5 MR C400, TRF 2.0
Cabinet Enclosure Rating / Material NEMA 3R / Painted Steel
Ambient temperature -30°C to +50°C without tank heaters
Seismic Rating Per IEEE / Low
Altitude ≤ 3,300’ ASL
Control Voltage 48 VDC or as Specified
Motor Voltage 240 VAC or as Specified
Alternate current circuit (lighting/heating): 120/240 VAC
Notes
* The X/R rating of the DT1-72.5 is 32 at 40kA. This breaker may be nameplated for up to 45kA interrupting current with a
standard X/R=17. This provides significant performance margin and ensures that the circuit breaker will perform at the
highest level with less maintenance.
The DT1-72.5 is qualified to M2 class for mechanical endurance in accordance with IEC 62271-100. This rating qualifies the
DT1-72.5 mechanically for 10,000 Close-Open operations without maintenance.
The DT1-72.5 is qualified to C2 class for capacitor switching in accordance with IEC 62271-100. This rating qualifies the DT1-
72.5 for switching of capacitive loads with very low probability of re-strike.
The foundation layout dimensions of the DT1-72.5 are 40.5” x 40.5”, allowing for simplified installation for new construction
as well as OCB replacement.
State of the art proprietary bushing sealing system improves SF6 gas tightness.
Porcelain Bushings are tested for high pollution environments using the salt-fog method.
ALSTOM has delivered over 6,500 DT1-72.5 circuit breakers since 1993.
Spare Parts
We do not recommend any spare parts for start up or the first three (3) years of operation; however, for the purpose of
comparison, we are giving the prices for the following spares:
* A slow close device was required for oil type breakers with interrupters with adjustable contact wipe. On SF6 interrupters, the
contacts never need adjusted during the life of the breaker. Therefore, the slow closing device does not add any functionality to
the breaker.
Prices of spare parts are valid only when they are ordered and delivered together with the circuit breaker. Spares ordered
separately will be subject to shipping charges.
We maintain all necessary spare parts in our stock. For emergency spares, we recommend items 1, 2 and 3.
Spare parts ordered separately will be subject to shipping charges.
Special Tools
No special tools are necessary for installation or maintenance of the breakers. We do recommend, however, having one (1) of
each of the following SF6 handling tools on site:
The cost of these special tools, unless otherwise stated, is not included in the breaker pricing.
Note:
This offer is subject to mutually agreed upon Terms & Conditions between City of Ocala and ALSTOM Grid, Inc. dated 02/27/2009. Please
refer to the attached Terms & Conditions.
General Conditions
General Comments
The circuit breakers offered belong to a family of switchgear highlighted by the following features:
Circuit Breaker
Operating Mechanism
Anti-pumping device
Anti-condensation heater
Two (2) independent trip coils, one (1) closing coil
Local mechanical C/O-operation
Aluminum access plate for conduit entrance
Removable door of housing with provisions for padlocks
Breaker position and spring charge indicators included
www.alstom.com
SERVICE QUOTATION
Quotation Validity: Sixty (60) Days from date of quotation Delivery: 4 to 6 weeks advance notice
required for scheduling
Terms and Conditions: Net Thirty (30) Days from date of invoice purposes.
(See attached for Alstom Grid Services standard "Terms and Conditions) This quotation is for
budgetary Purposes only.
Only One Mobilization and
Demobilization is included in
this quote.
Pricing in based per the
delivery Schedule 3 CBRs in
2012 only.
The 3 Circuit Breakers must
be installed on its foundation,
Grounded and AC and DC
power terminated inside the
control Cabinet prior to
Alstom Arrival
All prices included in this quotation are estimated. Invoicing will reflect actual cost.
Additional time, including daily expenses, incurred due to delays outside the control of Alstom Grid, to include but not limited to weather,
customer, material delivery delays, etc. will be charged up to eight hours per day at applicable rates. A handling charge will be added to all
charges for traveling and living expenses.
Scope of Work:
Exterior Inspection
Positive Pressure check
Funtional Check of Controls, Relays and Alarms
Timing of Main Contact
Measurement of Main Contact Resistnace
Cost Savings can be achieved if Technician Flys in the morning and start working in the afternoon.
6 Shipping (Circuit Breaker Timer and 100amp C/R Test Set)(R/T) 1 Each $690.00 $690.00
Total: $5,757.00
ALSTOM Grid
One Power Lane Signature:
Charleroi, PA 15022
Tel: 724-489-8133
Fax: 724-483-7771
www.alstom.com Date:
PURPOSE
This specification outlines the paint finish requirements for fabrications used in the assembly of power circuit
breakers. The specification applies to all fabrications made from material, such as ferrous material, which must
be coated and/or otherwise protected in order to prevent corrosion caused by continuous environmental
exposure. This specification also applies in cases where painting is performed for aesthetic purposes only and
corrosion protection is not an issue (i.e. aluminum substrates).
SCOPE
The specification applies to all AREVA T&D Inc. Manufacturing personnel, as well as all outside sources,
responsible for the painting of material used in the assembly of power circuit breakers.
GENERAL
The paint system defined by this specification is a two-part system, consisting of a hybrid epoxy primer and a
polyester (TGIC) topcoat, which is applied via electrostatic spray. All resistance properties required by this
specification are to be considered indicative of the system as a whole and do not necessarily reflect the
performance of either coating as individually applied.
SPECIFICATION
Coating Properties
1. Top Coat
2. Primer
UNCONTROLLED
QUALITY ASSURANCE TS-00005
AREVA T&D Inc. Charleroi Paint Finish Specification Rev. 4 Page 2/4
Test
Property Rating Specification
Method
Salt Fog Resistance ASTM B117 Creepage < 1/8" from scribe Minimum 2000 hours
("X" scribe) (ASTM D1654, Procedure A,
Method 1)
(Table 1)
C. Visual Criteria
1. Color
a. The following is to be furnished by the coating Supplier and is to accompany each unique
lot of powder coat material:
1. Spectrophotometric data representative of the production lot
a. Data is to be obtained through the use of a spectrophotometer using
the L*a*b* scale under a D 65 (daylight) illuminant.
b. Data should not represent a change in color > 1.00 ∆E from
approved spectrophotometric values.
2. One sample panel representative of the production lot, coated at nominal
mileage and displaying the following information:
B. Visual Criteria (Cont.)
• Color
• Supplier Product #
• Supplier Lot #
• Date
UNCONTROLLED
QUALITY ASSURANCE TS-00005
AREVA T&D Inc. Charleroi Paint Finish Specification Rev. 4 Page 3/4
• Mileage
c. For inspection purposes, the exactness of the coating's color will be verified
through:
1. Comparison to known spectrophotometric values (not to exceed a deviation of 1.00
∆E)
2. Visual comparison of the sample panel to an approved master panel* kept on file in the Quality
Assurance department. (Ref. Section E "Approval of New Color Masters")
(*NOTE: The "master panel" is a panel which is felt to most closely reflect a
coating's true color as agreed upon by the coating Supplier and Customer.
This panel will serve as the standard against which all production lots will be
judged for conformity of color.)
. General Appearance
a. During visual inspection, the sample panel provided by the coating Supplier will be also
assessed for general appearance (i.e. levels of gloss, orange peel, pin-holing, etc.)
b. Significant deviation in the general appearance of the production sample from the
approved master may result in the rejection of the production lot.
C. Application
1. Pretreatment
a. Ferrous Substrates
Substrate surface shall be pre-treated prior to coating application, using one of the two
procedures described below:
In either case, Supplier shall have sufficient inspection steps in place prior to substrate
preparation to ensure that substrate material is completely free of any deposits such as
tar, adhesives, or any substance that would be immune to routine surface preparation.
In order to be approved for use with ferrous substrates, a powder coating must
demonstrate the ability to meet all properties designated by Section B, Table1, when
applied in conjunction with the pretreatment defined by this specification.
b. Aluminum Substrates
UNCONTROLLED
QUALITY ASSURANCE TS-00005
AREVA T&D Inc. Charleroi Paint Finish Specification Rev. 4 Page 4/4
1.
Aluminum spinnings Clean surface with solvent prior to painting to remove any
grease, dirt, oils, etc.
2. Cast Aluminum Clean surface with solvent prior to painting to remove any
grease, dirt, oils, etc.
3. Wrought or Rolled aluminum Mechanically abrade surface and clean with
solvent to remove any residue before painting.
3. In order to be approved for use with aluminum substrates, a powder coating
must demonstrate the ability to meet all properties designated by Section B,
Table 1, with the exclusion of "Salt Fog Resistance" and "Environmental
Cycling" when applied in conjunction with the pretreatment defined by this
specification
2. Application of Coating
a. All powder coating is to be applied via electrostatic spray.
b. The User is to defer to the coating Supplier "Product Data Sheet" for product specifics
such as specific gravity, bake cycle, cure temperatures, etc.).
D. Approval of New Color Masters
1. Master panels used for visual reference will be retained for the period of two (2) years.
After the period of 2 years, due to degradation of color over time, a new master standard
must be approved for use. At this time, the Supplier will submit a new panel for approval.
To qualify as a replacement for a "color master", this new panel must exhibit a change in
color no greater than .2 ∆E from the original master standard when measured using a
spectrophotometer.
2. First-time color matches for all new coating Suppliers (existing colors) must exhibit a
change in color no greater than .2 ∆E from an already approved color master.
3. Spectrophotometric data and sample panels for all new colors must be submitted to
AREVA T&D Inc. for final approval of the color match. All color masters used by the
coating Supplier for inspection purposes must also be approved by AREVA.
E. Formulation Changes
1. AREVA T&D Inc. reserves the right to request the coating Supplier to provide the specific
formulation for a given powder coating at any time.
2. Under no circumstances are changes to be made by the coating Supplier to the original
approved formulation of a powder coating purchased by AREVA unless previously
approved by AREVA.
F. Touch-Up
Touch-up of nicks, scratches and other imperfections is to be performed per AREVA specification
TS-00006.
UNCONTROLLED
Alstom Grid Reference List
High Voltage Circuit Breakers: Charleroi, PA
Model: *DT1-72.5 FK
CABINET LIGHT
01CS BREAKER CONTROL SWITCH
KNIFE SWITCH
23 THERMOSTAT TOP VIEW OF CONTROL CABINET
23X HEATER CONTACTOR
1 COIL 27X LOSS OF POWER RELAY CONTROL STATION 1
CHARGING MOTOR 30 ANNUNCIATOR
MAX CONT. 37 UNDERCURRENT ALARM
PWR 4W 43L/R LOCAL / REMOTE TRANSFER SWITCH
49 MOTOR THERMAL OVERLOAD MECHANISM
CONTACT, DROP OUT
52a,b BREAKER AUXILIARY SWITCH
NORMALLY CLOSED PANEL
PUSHBUTTON 52C CLOSE PUSHBUTTON RELAY PANEL
52CC BREAKER CLOSE COIL
52T TRIP PUSHBUTTON
CONTACT, 52TC BREAKER TRIP COIL
NORMALLY OPEN RESISTOR/ HEATER 52X CLOSING RELAY
52Y ANTIPUMP RELAY
52-MON BREAKER CONDITION MONITOR
CONTROL TERMINALS
CONNECTOR 63G SF6 PRESSURE / DENSITY GAUGE GROUND BAR
TERMINAL BLOCK 63GX SF6 PRESSURE / DENSITY RELAY
69 PERMISSIVE CONTROL SWITCH
DENSITY MONITOR 69-KI KEY INTERLOCK BCT TERMINALS
AUXILIARY TERMINAL BLOCK
74CC CLOSE COIL MONITOR
2 74TC TRIP COIL MONITOR 2
79X RECLOSE DELAY RELAY
THERMOSTAT 83X MOTOR TRANSFER CONTACTOR
DOOR SWITCH 88 MOTOR
88F MOTOR FAILURE ALARM
88LS MOTOR LIMIT SWITCH
FUSE BLOCK AIL AMBER INDICATOR LIGHT
THERMAL OVERLOAD
GIL GREEN INDICATOR LIGHT
FUSE BLOCK, SLUGGED RIL RED INDICATOR LIGHT
HTR HEATER
FUSED DISCONNECT
TOGGLE SWITCH
FUSED DISCONNECT,
SLUGGED
FUSE PULLOUT
TRANSFORMER 3
3
FUSE PULLOUT, SLUGGED
28 ES:14 ES:A1
WIRING KEY
A B C D
A B C D
1 1 2
SW1
1
TB1 TB1
FU1 3
1 2
1 15A TB2
TB1 9AR
GIL REMOTE
TB2 CUSTOMER OPEN 1A 1 CUSTOMER
REMOTE EE
2 7R INDICATION REMOTE
RE CLOSE
52T1 RIL
+ TB3 TRIP
79X TB2
7 13 2 9R
TB2 SET RECLOSER
OPTIONAL
1 3 AT NO LESS
CUSTOMER
THAN 20 CYC.
LOCKOUT
TB2 TB9 TB9 SPARE TRIP COIL
8 109 100
2 21 ES
52Y
110
TB3
18
2
a
10
b
2
22 48 VDC
TB10 TB9
21 EA 116 101 5W
ADD JUMPER AT1
48 VDC 63GX1 3W
AT2 TO TRIP ON 5D
22 3D LOW SF6
MA1 1
D 3 MA1 13 ME
+
RE TB9 A1 B1 3 52-1 52-1 52TC2
79X 107 EML EGA a b 5.6 OHM
TB10 63G 14 2
4 MAX CONT.
111 88F 47.9 psig TB7
79 PWR 4W
4 C 11 MB1 A2 SET TDPU 4
88LS 6D
1 MA1 13 ES AT 20 SEC 3W AT1
52-1 b AT1
52Y TB10 12 4D 6W
a AT2 13 MA3 3D
113 52-3
2 14 4W TB10
1W b 1 119
AT1 14 MD
1D A1 52TC1
112 11 MA3 EA 5.6 OHM
TB10 1 52-3 63GX1 TB7 2 MAX CONT.
MC b 80
52CC PWR 4W
12 A2
5.6 OHM 4D
2 AT1
A1 ES 2D
MAX CONT.
PWR 4W TB10 4W
3
3 52Y
2W
AT1 115 TB9
108
TB10
117
3 4
A2 9 MA1
52-1 11 MA1 SW1 TB2
b 52-1 TB1 9A
10 b 2A
12
9 MB1
88LS A RE
b 79X
10
B SET TDPU
AT 20 CYC
TB10 NOTES:
FU1 114 1) ALL DEVICES SHOWN IN DE-ENERGIZED POSITION
TB1 15A 2) BREAKER SHOWN IN OPEN POSITION
23 4 3) SF6 SHOWN AT ZERO PRESSURE
4) CLOSING SPRING SHOWN IN CHARGED POSITION
TB1
4
A B C D
A B C D
1 5W 1W
DT1 MB1 AT2 AT2
49 5 5D 1D
88LS
10-16A a
6 5 EGA 1 EGA 53 EA 61 EA 83 EA 71 EA
2 63GX1 63GX1 63GX1 63GX1
63G 63G
3 47.9 psig 52.2 psig 54 62 84 72
DT1 6 2
49 TB9
10-16A 106 6D 2D
AT2 AT2
SPARE MOTOR 6W 2W
4
TB9 LIMIT SWITCH SPARE AUXILIARY SWITCHES FOR CUSTOMER USE
CONTACT
2
103
TB3 TB3 TB4 TB4 2
1 MB1 20 22 33 36 TB5 TB5 TB5 TB5 TB5 TB6 TB6 TB6 TB6 TB6
88LS 51 53 55 57 59 63 65 67 69 71
LOW GAS LOW GAS
a LOW GAS LOW GAS
LOCKOUT ALARM
2 LOCKOUT LOCKOUT
MA1 15 MA1 MA2 11 MA2 MA2 13 MA2 MA2 15 MA2 MA3 MA3
7 3 5 52-2 7 1 9
T1 52-1 52-1 52-2 52-2 52-2 52-2 52-2 52-3 52-3
120VAC M1 b
88 a b a b a a b a b
8 16 4 12 6 14 8 16 2 10
120VAC TB4 TB4
1.6 kW TB3 28 29
T2 24
TB5 TB5 TB5 TB5 TB5 TB6 TB6 TB6 TB6 TB6
52 54 56 58 60 64 66 68 70 72
3 MB1
88LS
a
4
12 14 TB7 TB7 TB7 TB7
TB9 21 DT1 EML 75 77 81 83
104 49 88F
5 22
DT1 11 MA3
3 5 MA3 7 MA3 15 MA3
49 52-3 52-3 52-3 52-3
10-16A a a a b
4 6 8 16
3 4 6
TB1 FU2
TB7 TB7 TB7 TB7 3
3 2B 20A/SLUG
TB3
25
TB4
30
76 78 82 84
NOTES:
1) ALL DEVICES SHOWN IN DE-ENERGIZED POSITION
2) BREAKER SHOWN IN OPEN POSITION
3) SF6 SHOWN AT ZERO PRESSURE
4) CLOSING SPRING SHOWN IN CHARGED POSITION
A B C D
A B C D
1 HEATERS
1
FU3
15A
TBAC
40 1 2
PHASE (HOT) WIRE
1
TH1
45-90 F
2
1W 3W
HT1 HT1
1D 3D
240 VAC 1 3 H1
H1
95 W 95 W
600 OHM 4 600 OHM
2
2D 4D
HT1 HT1
2W 4W
TBAC
41 3 4
PHASE (HOT) WIRE
2
FU3
15A
2
1 2
FU4
20A
1
120 VAC LS1
4 PL1
120 VAC 2
2 1 20 A L1
L1
1 - LINE
3 2 - NEUTRAL GND L1
3 - GND L2
5 4 - LOAD LINE
TBAC 5 - LOAD NEUTRAL
42
NEUTRAL WIRE
3
3 TH1
7 EGA
63G
GND 7D
AT2
7W GND1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
NOTES:
1) ALL DEVICES SHOWN IN DE-ENERGIZED POSITION
2) BREAKER SHOWN IN OPEN POSITION
3) SF6 SHOWN AT ZERO PRESSURE
4) CLOSING SPRING SHOWN IN CHARGED POSITION
A B C D
A B C D
SW1:2,AT2:3W
0
3
A
1
ES:A2,TB1:4
SW1:3,TB1:2 2A 31 EA:53
ES:13,RE:3
1
3
A
2
FU2:1 1B 32 EA:61
EML:A1
TB2:9A
2
3
TB3:13
B
1
ES:A1
EA:32
DT1:5
DT1:4
FU2:3 2B 33 EA:54
RE:A
RE:C
RE:D
3
B
2
FU1:2 3
3
34
4
3 EA:83
TB10
TB9
TB10:114,RE:B 4 35 EA:71
120
119
MA2:1 118
117
116
MA1:11 115
114
113
110
109
108
MB1:11 107
106
105
104
MB1:1 103
100
122
121
112
MA1:1 111
102
101
99
5
3
4
1
2
2
1
1
2
0
1
9
1
8
1
7
1
6
1
5
1
4
1
3
1
2
1
0
1
0
9
1
0
8
1
0
7
1
0
6
1
0
5
1
0
4
1
0
3
1
0
2
0
1
1
0
9
5
5
36
6
3 EA:84
MA1:2
MA3:12
MB1:10,MA1:12
MA1:3
MB1:14,MB1:8
MB1:7
MB1:6
MB1:5
MB1:4
MA2:9
MA1:13
MB1:13
AT1:6W
AT1:4W
AT1:1W
6
6
37
7
3
B1
B
1
38
8
3
B2
B
2
39
9
3
TB2
TB2:7R 7
7 TB2:8
TB2:7 7R
R
7
LA1:1 8
8 TB2:7
EA:31 9
9
EA:31,EE:2 9R
R
9
TB10:117,TB7:80 9A
A
9
EA:13,EE:1 9ARA
R
9
10
MA2:11
MA2:12
MA3:16
MA3:15
MA3:14
MA3:13
MA3:10
MA2:16
MA2:15
MA2:14
MA2:13
MA1:16
MA1:15
0
1
MA3:1
MA3:2
MA3:8
MA3:7
MA3:6
MA3:5
MA3:4
MA3:3
MA3:9
MA2:8
MA2:7
MA2:6
MA2:5
MA2:4
MA2:3
MA1:8
MA1:7
10A
A
0
1
2
11
1
TB7
TB6
TB5
11A
71
62
86
85
84
83
82
81
80
79
78
77
76
75
74
73
70
61
59
58
57
56
55
54
53
52
51
72
69
68
67
66
65
64
63
60
A
1
6
8
5
8
4
8
3
8
2
8
1
8
0
8
9
7
8
7
6
7
5
7
4
7
3
7
2
7
1
7
0
7
9
6
8
6
7
6
5
6
4
6
3
6
2
6
1
6
0
6
9
5
8
5
7
5
6
5
4
5
3
5
2
5
1
5
B3
B
3
TB2:9A,EA:A2
TB3
TB10:115 13
3
1
EA:14 17
7
1
EA:32 18
8
1
AT2:5W 19
9
1
AT2:6W 20
0
2
AT2:1W 21
1
2
AT2:2W 22
2
23
3
2
DT1:21 24
4
2
TBAC
DT1:22 25
5
2
40 FU3:1
26
6
2
41 FU3:3,FU4:1
27
7
2
42 PL1:2
GND1
1 2 3 4 5 6 7 8 9 10 11 12
3
3 13 14 15 16 17 18 19 20 21 22 23 24
1 TH1:GND
2 L1:GND,PL1:3
4 AT2:7W
NOTES:
1) ALL WIRING TO BE 12GA GRAY SIS VW1
2) ALL GROUND WIRING TO BE 12GA GREEN SIS VW1
3) WIRE MARKERS TO BE SHRINK-TYPE AND TO SHOW
SAME-END/OPPOSITE-END DESIGNATION
4) WIRE LUGS ARE TO BE BURNDY TYPE INSULATED "YAEV"
(EXCEPT FOR DEVICES THAT DO NOT ACCEPT
RING-TYPE TERMINALS)
A B C D
A B C D
2
1 3 5 7 9 11 13 15 2
3
AT1:5W
TB5:55
10
11
AT1:5W
TB5:57
2
4 TB5:56 12 TB5:58
a a a a b b b b 5 TB5:59 13 TB6:63
AT1 MD 52TC1 ME 52TC2 2 4 6 8 10 12 14 16 6 TB5:60 14 TB6:64
M1 88 MC:1 1D 1W TB10:113 1 AT1:3D 1 AT1:5D 7 TB6:65 15 TB6:67
1 1
2 AT1:4D 2 AT1:6D 8 TB6:66 16 TB6:68
T1 T1 MB1:2 MC:2 2D 2W MA1:9
T2 MB1:3 MD:1 3D 3W MA1:4,MA1:14 MA3 52-3
MD:2 4D 4W TB10:117 1 TB6:69 9 TB6:71
1 3 5 7 9 11 13 15 2 TB6:70 10 TB6:72
ME:1 5D 5W MA2:2,MA2:10 2 2
3 TB7:75 11 MB1:12
T2 ME:2 6D 6W TB10:119 COIL VOLTAGE - 48 VDC COIL VOLTAGE - 48 VDC 4 TB7:76 12 TB9:108
MOTOR VOLTAGE - 120VAC COIL RESISTANCE - 5.6 OHM COIL RESISTANCE - 5.6 OHM a a a a b b b b 5 TB7:77 13 TB7:79
WATTAGE - 1.6 kW 2 4 6 8 10 12 14 16 6 TB7:78 14 TB7:80
7 TB7:81 15 TB7:83
8 TB7:82 16 TB7:84
EE 52T1
1 3 1 TB2:9AR
2 TB2:9R
HT1
2 4
3
2W HT1:4W,FU3:4
3W TH1:1,FU3:2
3 COLOR - BLK
4W HT1:2W
1W TH1:2
1 3 1 TB2:8 1 FU4:2
2 ES:21 2 1 2 TBAC:42
3 GND1:2
H1
H1:2 2D
H1:3 3D
H1:4 4D
5D
6D
H1:1 1D
4 LS1:1
1 3 1 HT1:1D 5 L1:L2
2 4 2 HT1:2D
3 HT1:3D 1 - LINE
4 HT1:4D 3 2 - NEUTRAL NOTES:
3 - GND 1) ALL WIRING TO BE 12GA GRAY SIS VW1
2 4 4 - LOAD LINE
5 2) ALL GROUND WIRING TO BE 12GA GREEN SIS VW1
5 - LOAD NEUTRAL 3) WIRE MARKERS TO BE SHRINK-TYPE AND TO SHOW
WATTAGE - 2X 95 W VOLTAGE - 120 VAC SAME-END/OPPOSITE-END DESIGNATION
RESISTANCE - 2X 600 OHM AMP RATING -20 A 4) WIRE LUGS ARE TO BE BURNDY TYPE INSULATED "YAEV"
(EXCEPT FOR DEVICES THAT DO NOT ACCEPT
RING-TYPE TERMINALS)
A B C D
A B C D
RELAY PANEL WIRING
TH1
1 1 HT1:3W
2 HT1:1W
GND GND1:1
1 GND
1
2
TEMP SETTING - 45-90 F
RE 79X
A TB9:108
D 2 A B TB1:4
+ + D EA:22,TB9:107
C TB10:113
2 FU1:2
3 TB10:111
4 C 1 3 B
COIL VOLTAGE - 48VDC/48VAC
COIL RESISTANCE - SOLID STATE
2 13
14
SW1:2,TB2:9AR
TB3:17
13
14
ES:21,TB10:111
ES:A1
12 TB4:28
11 TB4:30
3
4
DT1:2
TB9:103
2
21 ES:22 21 ES:13,LA1:2 14 TB4:29 5 TB9:104
22 RE:D 22 EA:21 6 FU2:4
14 44 22 32 A2 14 44 22 32 A2 11 21 A2 2 4 6 14 22 21 TB3:24
31 TB2:9,TB2:9R
32 TB3:18,TB10:116 COIL VOLTAGE - 48VDC COIL VOLTAGE - 48VDC AMP RATING - 10-16A 22 TB3:25
53 83 61 71
53 TB4:31 COIL RESISTANCE - 852 ohm COIL RESISTANCE - SOLID STATE
54 EA:62,TB4:33
61 TB4:32
62 EA:54
54 84 62 72 71 TB4:35
72 EA:84
COIL VOLTAGE - 48VDC 83 TB4:34
COIL RESISTANCE - 852 ohm 84 EA:72,TB4:36
AT2
FU1 SW1 FU2 FU3 FU4 TB3:21 1W 1D EGA:1
1 3 1 TB1:1 1 3 1 TB1:1A
2 EA:13,TB9:109 1 3 1 TB1:1B 1 3 1 TBAC:40 1 1 TBAC:41 TB3:22 2W 2D EGA:2
2 RE:2,TB1:3 2 DT1:1 2 HT1:3W 2 PL1:1
3 TB1:2 3 TB1:2A TB9:109 3W 3D EGA:3
4 EML:A2 3 TB1:2B 3 TBAC:41
4 ES:A2 4 DT1:6 4 HT1:2W EA:A1 4W 4D EGA:4
TB3:19 5W 5D EGA:5
2 4
TB3:20 6W 6D EGA:6
GND1:4 7W 7D EGA:7
3
3 2 4 2 4 2 4 2
AMP RATING - 15A AMP RATING - 20A/SLUG AMP RATING - 15A AMP RATING - 20A
NOTES:
1) ALL WIRING TO BE 12GA GRAY SIS VW1
2) ALL GROUND WIRING TO BE 12GA GREEN SIS VW1
3) WIRE MARKERS TO BE SHRINK-TYPE AND TO SHOW
SAME-END/OPPOSITE-END DESIGNATION
4) WIRE LUGS ARE TO BE BURNDY TYPE INSULATED "YAEV"
(EXCEPT FOR DEVICES THAT DO NOT ACCEPT
RING-TYPE TERMINALS)
A B C D
A B C D
CONTROL TERMINALS
GROUND BAR
BCT TERMINALS
L1
LS1
L1
40 W
*
ON "L" BKT
LOWER EDGE MFR WIREWAY 2X2 - MOUNTED TO BACK OF MECH PANEL
TB10
TB1 TB4
* *
TB9
T H1
2X 1X 2Y 1Y
2 2
MFR WIREWAY 1.5X3 MC
MFR WIREWAY 1X3
MFR WIREWAY 1.5X3
RE
MB1 MC
4X 3X 4Y 3Y
*
MB1
88LS
MFR WIREWAY 2X3
MA1
MDMD
ME ME MA1
79X
6X 5Y
5X 6Y
M1
MA2
*
88
MA2
52-2
MA3
52-3
*
STOP START
AT1
TB3 DT 1
EML
88F 49
* FU1
FU1
15A
SW1
SW1
30 AMP
FU2
FU2
20A/SLUG
MFR WIREWAY 1X3
FU3 FU3
15A
FU4
FU4
20A
TB6
TB7
TB5
TBAC
AT2
AT2
3
3 MFR WIREWAY 1X3
MOUNTED THROUGH H1
CABINET DOOR
PL1 H1
PUSH TO
PL1
GFI
2X 95 W
GND1
E-TRIP RESET HT1
LOCKOUT HT 1
EE LA1
EE
E-TRIP RESET
LA1
A B C D
A B C D
ITEM QTY AREVA # MFR # MFR DESCRIPTION DEVICE ID
001 001 1_410_508_P6 CR104 GENERAL ELECTRIC CONTACT BLOCK EE
002 001 1_410_632_P19 1-410-632-P19 AREVA CABINET LIGHT L1
003 001 1_417_123_P1 E69-30A CHERRY DOOR SWITCH LS1
004 001 1_410_634_P9 TSA901 ELECTROMODE ADJUSTABLE THERMOSTAT 45-90F TH1
005 001 1_410_635_P10 201-J STATES KNIFE SWITCH 1 POLE FU4
006 004 1_410_635_P9 202-AW STATES KNIFE SWITCH 2 POLE FU1, FU2, FU3, SW1
007 001 1_410_636_P2 7360K8 CUTLER HAMMER PERMISSIVE CONTROL SWITCH LA1
1 008 002 1_410_640_P19 IH3-1 THOMAS & BETTS / RED DOT RECEPTACLE, ENCLOSURE PL1, TH1
1
009 001 1_410_640_P4 WPFS26 HUBBELL RECEPTACLE, WEATHERPROOF COVER PL1
010 001 1_410_640_P5 GF5352A OR = HUBBELL RECEPTACLE, GFI, 120VAC, 20A PL1
011 002 1_410_641_P73 CLIPFIX35-5 PHOENIX END CLAMP END5, END6
012 004 1_410_650_P6 1-410-650-P6 AREVA FUSE, 15A, CLASS RK5 FU1, FU1, FU3, FU3
013 002 1_410_650_P7 1-410-650-P7 AREVA FUSE, 20A, CLASS RK5 FU2, FU4
014 001 1_410_748_P10 1423123 MARATHON TERMINAL BLOCK 3PT 200A TBAC
015 001 1_410_748_P11 CC1423 MARATHON TERMINAL BLOCK COVER TBAC
016 001 1_410_749_P200 CS8C-22Z-48D SPRECHER + SCHUH CONTROL RELAY 2NO 2NC (48 VDC) ES
017 001 1_410_749_P200 CS8C-22Z-48D SPRECHER + SCHUH CONTROL RELAY 4NO 4NC (48 VDC) EA
018 001 1_410_749_P208 CS8-P22 SPRECHER + SCHUH AUXILIARY CONTACT EA
019 001 1_410_906 1_410_906 AREVA E-TRIP / 69 BLOCK LA1
020 001 1_412_934_P5 1-412-934-P5 AREVA SLUG FU2
021 003 1_413_318_P10 6012 Penn-Union TERMINAL BLOCK 12PT TB1, TB2, TB3
022 001 1_413_318_P10 6012 Penn-Union TERMINAL BLOCK 12PT TB4
023 036 1_413_318_P11 SCP-1 PENN UNION SHORTING SCREW 2X, 2X, 2X, 2Y, 2Y, 1X, 2Y, 3X, 3X, 3X, 3Y, 3Y
1X, 3Y, 4X, 4X, 4X, 4Y, 4Y, 1X, 4Y, 5X, 5X, 5X
5Y, 5Y, 5Y, 6X, 6X, 6X, 6Y, 6Y, 6Y, 1Y, 1Y, 1Y
024 012 1_413_318_P3 6006-SCS PENN UNION TERMINAL BLOCK 6PT, SHORTING 1Y, 2X, 2Y, 3X, 3Y, 4X, 4Y, 5X, 1X, 5Y, 6X, 6Y
025 001 1_413_652_P1 1017SP7-A-4-B KANSON TIME DELAY RELAY, 2 FORM "C", 48V, 1.5-120 CYC RE
026 001 1_413_653_G8 700-HT1 ALLEN-BRADLEY TIME DELAY RELAY, 2 FORM "C", 48VDC EML
027 001 1_413_999_G3 17000_0, PCN 265480 CHROMALOX ANTICONDENSATION HEATER ASSY 240VAC H1
2 028 007 1_416_091 1-416-091 AREVA COPPER STRAP FU1, FU1, FU2, FU2, FU3, FU3, FU4 2
029 001 1_416_206_P4 1-416-206-P4 AREVA TERMINAL BLOCK COVER AUX 6PT 25
030 001 1_417_056_P1 1-417-056-P1 AREVA SWITCH BRACKET LS1
031 001 1_417_125_P1 GEL 40A15/120V 15199 GE LIGHT BULB 40W 120VAC L1
032 001 2_990_024_P2 2-990-024-P2 WIKA DENSITY MONITOR (67,52,48) PSIG-BAR SCALE-PURE SF6 EGA
033 001 2_990_035_P1 2-990-035-P1 AREVA MECHANISM PANEL PAN28
034 001 2_990_156_P2 2-990-156-P2 AREVA DT72.5 RELAY PANEL PAN29
035 006 2_991_268_P1 2-991-268-P1 AREVA 6PT TB MOUNTING STRIP-NEW PAN25, PAN27, PAN30, PAN31, PAN32, PAN33
036 001 1_410_508_P1 CR104PBG10B1 GENERAL ELECTRIC PUSHBUTTON, BLACK, 2NO EE
037 001 1_410_748_P1 TB206 BUSSMANN AUX. TERMINAL BLOCK, 6 PT AT1
038 001 1_410_748_P1 TB206 BUSSMANN AUX. TERMINAL BLOCK, 6 PT HT1
039 001 1_410_748_P3 TB207 BUSSMANN AUX. TERMINAL BLOCK, 7 PT AT2
040 002 1_410_651_P2 RF30A2SP1 MARATHON FUSED KNIFE SWITCH 2 POLE, 15A FU1, FU3
041 001 1_410_651_P3 RF30A1SP1 MARATHON FUSED KNIFE SWITCH 1 POLE, 20A FU4
042 001 1_410_651_P2 RF30A2SP1 MARATHON FUSED KNIFE SWITCH 2 POLE, 20A/SLUG FU2
043 001 GROUND_BAR AREVA GROUND BAR, 24PT GND1
044 003 1_413_318_P10 6012 Penn-Union TERMINAL BLOCK 12PT TB5, TB6, TB7
045 002 1_413_318_P10 6012 Penn-Union TERMINAL BLOCK 12PT TB10, TB9
046 001 1_417_294_G8 1-417-294-G8 AREVA SPRING CHARGE MOTOR FOR FK3-1/131 M1
047 001 1_966_957 MBS 25 AEG THERMAL OVERLOAD 10-16A DT1
048 003 49.102.110-16 49.102.110-16 AREVA COIL (48 VDC) MC, MD, ME
049 004 49.105.100-01 49.105.100-01 AREVA AUXILIARY SWITCH FK3-X MA1, MA2, MA3, MB1 3
3
A B C D
A B C D
BCT WIRING
2X 1X 2Y 1Y
2X-X1 2X1 1X1 1X-X1 2Y-X1 2Y1 1Y1 1Y-X1
1 2 3 4 5 6
2X-X2 2X2 1X2 1X-X2 2Y-X2 2Y2 1Y2 1Y-X2
2X-X3 2X3 1X3 1X-X3 2Y-X3 2Y3 1Y3 1Y-X3
2X-X4 2X4 1X4 1X-X4 2Y-X4 2Y4 1Y4 1Y-X4
1 X1 X1 X1 X1 X1 X1 2X-X5
GND
2X5
GND
1X5
GND
1X-X5
GND
2Y-X5
GND
2Y5
GND
1Y5
GND
1Y-X5
GND
1
X2 X2 X2 X2 X2 X2
4X 3X 4Y 3Y
X3 1X 2X X3 X3 3X 4X X3 X3 5X 6X X3 4X-X1 4X1 3X1 3X-X1 4Y-X1 4Y1 3Y1 3Y-X1
4X-X2 4X2 3X2 3X-X2 4Y-X2 4Y2 3Y2 3Y-X2
X4 X4 X4 X4 X4 X4 4X-X3 4X3 3X3 3X-X3 4Y-X3 4Y3 3Y3 3Y-X3
4X-X4 4X4 3X4 3X-X4 4Y-X4 4Y4 3Y4 3Y-X4
X5 X5 X5 X5 X5 X5 4X-X5 4X5 3X5 3X-X5 4Y-X5 4Y5 3Y5 3Y-X5
X1 X1
GND GND GND GND GND GND GND GND
X1 X1 X1 X1
X2 X2 X2 X2 X2 X2 6X 5X 6Y 5Y
6X-X1 6X1 5X1 5X-X1 6Y-X1 6Y1 5Y1 5Y-X1
X3 X3 X3 X3 X3 5Y X3
1Y 2Y 3Y 4Y 6Y 6X-X2 6X2 5X2 5X-X2 6Y-X2 6Y2 5Y2 5Y-X2
6X-X3 6X3 5X3 5X-X3 6Y-X3 6Y3 5Y3 5Y-X3
X4 X4 X4 X4 X4 X4 6X-X4 6X4 5X4 5X-X4 6Y-X4 6Y4 5Y4 5Y-X4
6X-X5 6X5 5X5 5X-X5 6Y-X5 6Y5 5Y5 5Y-X5
X5 X5 X5 X5 X5 X5
GND GND GND GND GND GND GND GND
2 CT WIRING NOTES:
2
1) LEADS TO BE TERMINATED WITH BURNDY TYPE INSULATED "YAEV" LUGS.
2) ALL CT LEADS ARE TO BE SHORTED BEFORE SHIPMENT. IF TERMINAL BLOCKS ARE NOT
EQUIPPED WITH INTEGRATED SHORTING BARS - SHORTING TO BE ACCOMPLISHED WITH
10GA GRAY SIS VW1 WIRE JUMPERS. WHT-BLK-GND.
POLE 1 POLE 2 POLE 3 (IF LEADS ARE NOT COLOR CODED SHORT THE FIRST LEAD-THE LAST LEAD-GROUND)
3) ALL BCT LEADS ARE 10GA WIRE.
4) ALL GROUND WIRES ARE 10GA GREEN SIS WIRE.
BCT NAMEPLATE
X1 X2 X3 X4 X5
RATIO: 1200:5 MR
1 2
ACC: C400 3
3 FREQ: 60 Hz
RF: 2.0
3 4 PART No.: 1-417-048-N10014
POS: 1X~6X, 1Y~6Y
X2-X3 100:5
5 6
X1-X2 200:5
X1-X3 300:5
X4-X5 400:5
CT MFG: NARAYAN
X3-X4 500:5
X2-X4 600:5
BUSHING 1 2 3 4 5 6 X1-X4 800:5
UPPER X X X X X X X3-X5 900:5 BCT NAMEPLATE NOTES:
LOWER Y Y Y Y Y Y X2-X5 1000:5 1) NAMEPLATE MATERIAL: ALUMINUM
X1-X5 1200:5 2) NAMEPLATE LOCATION: INTERNAL
3) NAMEPLATE DIMENSIONS AS SHOWN ON AREVA DRAWING 1_416_218_P3/4
A B C D
A B C D
RATINGS NAMEPLATE
1 1
RATED MAXIMUM VOLTAGE RATED INTERRUPTING TIME SF6 PRESSURE (@ 20˚C / 68˚F)
72.5 kV RELATIVE PRESSURE
3.0 CYCLES
RATED VOLTAGE RANGE FACTOR (K) RATED SHORT CIRCUIT CURRENT -NORMAL OPERATING PRESSURE
66.7 psig
1.0 -TERMINAL FAULT 31.5 kA
-LOW PRESSURE ALARM
1/4" NPT RATED FREQUENCY 52.2 psig
60 Hz -90% SLF WITH 0nFL_g CAPACITANCE -MINIMUM PRESSURE
DUTY CYCLE (WITHIN 100m) 47.9 psig
2 O-0.3s-CO-15s-CO
31.5 kA
WEIGHT OF GAS
2
MANIFOLD FILL VALVE 29 lb
RATED CONTINUOUS CURRENT
3-WAY BALL TOTAL WEIGHT
1200 A TEMPERATURE RANGE
TEST VALVE
CAPACITANCE CURRENT SWITCHING -40˚C to +40˚C 3677 lb
3
3 66.7 psig - NORMAL
52.2 psig - ALARM
47.9 psig - LOCKOUT
NOTES:
1) ALL TUBING IS 3/8" STAINLESS.
2) GAS SAMPLING CAN BE DONE THROUGH FILL VALVE.
3) POLE ISOLATION VALVES USED TO ISOLATE TANK FROM GAS PIPING.
4) PRESSURE SWITCHES ARE LOCATED INSIDE THE DENSITY GAUGE HOUSING
A B C D
A B C D
20A/SLUG 15A GFI 52-1 52-2 52-3 20A 79X 2A 9 19 31 54 66 78 102 114
1X1 1Y1 2X1 2Y1 3X1 3Y1 4X1 4Y1 5X1 5Y1 6X1 6Y1 2B 9A 21 33 56 68 80 104 116
2 2
1X2 1Y2 2X2 2Y2 3X2 3Y2 4X2 4Y2 5X2 5Y2 6X2 6Y2 3 9AR 22 34 57 69 81 105 117
EE - LA1 - 69
52T1 E-TRIP 1X3 1Y3 2X3 2Y3 3X3 3Y3 4X3 4Y3 5X3 5Y3 6X3 6Y3 4 10 23 35 58 70 82 106 118
LOCKOUT
TBAC
1X4 1Y4 2X4 2Y4 3X4 3Y4 4X4 4Y4 5X4 5Y4 6X4 6Y4 5 10A 24 36 59 71 83 107 119 40
59 mm
1X5 1Y5 2X5 2Y5 3X5 3Y5 4X5 4Y5 5X5 5Y5 6X5 6Y5
RESET 6 11 25 37 60 72 84 108 120
41
GND GND GND GND GND GND GND GND GND GND GND GND B1 11A 26 38 61 73 85 109 121
COLOR - BLACK 3
3 COLOR - RED W/ WHITE TEXT W/ WHITE TEXT
48 mm 42
B2 B3 27 39 62 74 86 110 122
P12 P12 P12 P12 P12 P12 P12 P12 P12 P12 P12 P12 P11 P11 P11 P11 P11 P11 P11 P11 P11 P10
A B C D
A B C D
31.18 20.67
792 525
.875
1 22
1
10.04
255
2 2
1.75 1.75
44 44 .56 TYP 4 PLACES BOLT CIRCLE
.56 1.62
1.62 TYP 4 PLACES 8.86"
14 41 14 DIAMETER
41 225mm
1.13
29
1.75
1.75
44
44
1.35
34
203
8
11.77
299
3
3 BUSHING DATA
MATERIAL: PORCELAIN
BOTH SURFACES FINISHED FOR STRIKE DISTANCE: 643 mm / 25.3 in.
USE AS CONNECTION POINT
CREEPAGE DISTANCE: 1891 mm / 74. in.
BIL: 350 kV
COLOR: GRAY
HIGH VOLTAGE CONNECTION: ALUMINUM - NEMA 4 - THRU HOLE
TOP CAP PLATING: NONE
A B C D
UNCONTROLLED
GRID
PRODUCTS
Circuit Breakers
Warranty - We warrant, to the original purchaser, only, that the equipment supplied under this contract will conform to the
description thereof as contained in our offer, and there are no other warranties, express or implied, which extend beyond the said
description, nor any such warranties of fitness for any particular purpose or of merchantability. Such express warranty is given on
behalf of the seller only, and is expressly in lieu of an excludes and supersedes any warranty of merchantability or fitness for any
particular purpose, and all other warranties, express or implied from any other person or entity including the manufacturer or any
subcontractor. In accordance with this warranty, we will correct either by repair, or by the supply of a replacement part, or
compensate therefore by equitable adjustment of the contract price, at our sole option, any defect which may be disclosed after
delivery or during proper use of the equipment, and which is due solely to faulty design, materials or workmanship not in accordance
with the said description; provided, however, that the purchaser gives us written notice of such defect promptly after it is discovered
or within a reasonable time after It should have been discovered, and in any event, not later than twelve (12) months after
installation, or eighteen (18) months after delivery, whichever occurs later. If such notice of defect is not so given, our obligation to
correct such defect or breach of warranty, and constitutes our entire liability, and neither we, the manufacturer nor the subcontractor
or their employees or agents shall be liable for any injury, loss or damage whatsoever, which the purchaser may suffer or incur by
reason of any such defect or of the necessity of correcting the same, whether a claim is based on breach of contract, negligence,
strict tort or any other legal theory.
In no event shall we be liable, nor shall the manufacturer or any subcontractor or their employees or agents be liable, in connection
with a claim based on a breach of warranty as described in the above paragraph or any other duty or warranty contained in any other
paragraph or provision of this contract, for any special, incidental, or consequential damages, based upon breach of warranty, breach
of contract, negligence, strict tort or any other legal theory. Such exclusion shall include, but is not limited to, loss of profits, loss of
savings, or revenue, loss of use of any equipment, facilities, or services, injury to persons, downtime, and all claims of third parties,
(whether such third-party claims are for personal injury or loss to property). However, we will indemnify the purchaser against
direct damage or injury to the purchaser’s property or to persons of others which is caused solely by the active negligence of our
representatives while at the site of equipment installation for the purpose of the contract, up to the sum of contract value.
The special and general terms and conditions included in the Request for proposal for this project, which are referenced in this
quotation, are hereby accepted by ALSTOM Grid, Inc. subject to the following clarifications and exceptions which shall prevail in the
event of discrepancy.
1. Limitation of Liability: Notwithstanding anything to the contrary in the contract documents but to the extent permitted by law
Seller shall not in any circumstances under any legal theory, whether based on contract, warranty, tort (including negligence), strict
liability, indemnity, professional liability or otherwise, be liable to indemnify the loss of use, loss of production, loss of profits, loss of
contracts, loss of data, cost of capital, replacement power, claims of Buyer's Buyers, or any other financial or economic loss or any
special, incidental, punitive, indirect or consequential loss or damage whatsoever whether suffered by the Buyer or by any third party.
If the Seller fails to deliver the products in accordance with the contract schedule, Seller shall pay to the City of Ocala liquidated
damages at a rate of 1% of the price of the delayed products per full week of delay, not to exceed 5% of the price of such delayed
products. Liquidated damages shall be the Seller’s exclusive liability and the City of Ocala’s exclusive remedy for delayed
performance, provided however that the City of Ocala may terminate this contract or exercise any other remedies set forth herein or
otherwise provided by law once the maximum amount of liquidated damages has been reached. The parties agree that such amounts
are a reasonable pre-estimate of the damages the City of Ocala will suffer as a result of delay based on circumstances existing at the
time the contract was formed and are to be assessed as liquidated damages and not as a penalty.
2. Warranty: The Seller warrants that services will be performed in accordance with good standard practice and products shall be
free from defect in design, material and workmanship.
The contract warranty period shall be twelve (12) months from the product's commissioning or eighteen (18) months from
shipment, whichever is shorter.
During the warranty period, the Seller shall re-perform, repair or, at its sole discretion, replace any defective products or parts thereof
at its own costs. Buyer shall be responsible for accessing, dismantling and reinstalling the products at its risks and costs.
This warranty is exclusive of any other warranty whether express, implied, statutory or otherwise including the warranty of
merchantability and fitness for a particular purpose. Seller's liabilities and Buyer's remedies in respect of defects in the products or
services and any damage to the products however caused are solely and exclusively as stated in this clause and Seller shall have no
liability of any kind for any such defects or damage which appears after expiry of the warranty period described above.
3. Approval of drawings and other documents: Whenever the Buyer must approve drawings or other documents, the Buyer shall
approve or comment on those documents within fifteen (15) days of the receipt thereof.
4. Acceptance of the products: The products shall be deemed accepted unless rejected within 30 days of the delivery thereof.
5. Waiver of anticipatory breach remedy: The Buyer hereby waives its right to terminate the contract based on the concept of
anticipatory breach except in the event the Seller abandons or notifies the Buyer of its intention to abandon the performance of this
Agreement.
6. Termination for cause: Except in the event the Seller becomes insolvent or bankrupt, commences or has commenced against it
any insolvency or bankruptcy proceeding, finds its affairs placed in the hands of a receiver, trustee, or assignee for the benefit of
creditors, the Buyer shall not terminate this contract for cause unless the Seller fails to initiate and pursue actions to cure such
breach diligently upon written notice from the Buyer.
7. Termination for convenience: If the General terms and conditions allow the Buyer to terminate the contract for convenience,
Buyer shall pay to Seller amounts owed at the time of termination and reimburse the Seller for reasonable costs and expenses
incurred (i) in performing the agreement up to the date of termination and (ii) as a result of the termination.
8. Jurisdiction and Venue. The Parties acknowledge that a majority of the negotiations, anticipated performance and execution of
this Agreement occurred or shall occur in Marion County, Florida. Any civil action or legal proceeding arising out of or relating to this
Agreement shall be brought only in the United States District Court, Middle District of Florida, Ocala Division. Each party consents to
the exclusive jurisdiction of such court in any such civil action or legal proceeding and waives any objection to the laying of venue of
any such civil action or legal proceeding in such court or the right to bring an action or proceeding in any other court. Service of any
court paper may be affected on such party by mail, as provided in this Agreement, or in such other manner as may be provided under
applicable laws, rules of procedures or local rules.
9. Jury Waiver. In any civil action, counterclaim, or proceeding, whether at law or in equity, which arises out of, concerns, or relates
to this Agreement, any and all transactions contemplated hereunder, the performance hereof, or the relationship created hereby,
whether sounding in contract, tort, strict liability, or otherwise, trial shall be to a court of competent jurisdiction and not to a jury,
Each party hereby irrevocably waives any right it may have to a trial by jury. Any party may file an original counterpart or a copy of
this Agreement with any court, as written evidence of the consent of the parties hereto of the waiver of their right to trial by jury.
Neither party has made or relied upon any oral representations to or by any other party regarding the enforceability of this provision.
Each party has read and understands the effect of this jury waiver provision.
10. Confidentiality-Ownership: All designs, drawings and other technical information relating to the products and
services provided by the Seller under this Agreement, and the intellectual property rights therein made or acquired by the
Seller prior to or during the performance of this Agreement shall be and remain the property of the Seller. Such technical
information shall be kept confidential by the Buyer and shall not be used by Buyer otherwise than for the purposes of the
operation and maintenance of the products.
11. Suspension by Seller: Suspension: If Buyer fails to make any payment when due or perform on time any of its
other obligations under this Contract and without prejudice to any other rights or remedies: (i) Seller shall be entitled to
suspend performance of the Agreement until the failure is remedied, (ii) the time for performance of the Agreement by
Seller shall be extended accordingly, (iii) any cost (including financial costs and storage, demurrage or other charges)
thereby incurred by Seller shall be paid by Buyer.
Seller may terminate this Contract if the suspension exceeds three (3) months. In such event, the Seller shall be entitled
to the payment of (i) sums due (ii) costs incurred in the performance of the Contract up to the date of termination and
not already paid and (ii) costs incurred as a result of termination.
13. Miscellaneous:
13.1 If (i) Buyer refuses to confirm that it will take delivery of the product in accordance with the terms of this contract,
(ii) does not take delivery of the product within 30 (thirty) days of notification that the product is ready for delivery (iii)
postpones the date of delivery of the product without the prior written consent of Seller or (iv) suspend performance of
the contract without the consent of the Seller, after completion of manufacture and testing of the Product or for a period
exceeding in the aggregate three (3) months, and without prejudice to any other right or obligation that the Seller may
have under the Contract, at law or in equity, the Seller will be entitled to compete the manufacture of the product and
may store the Product at the risks and costs of the Buyer. In such instance, title to the Product shall pass to the Buyer
and Seller shall be entitled to payment of the contract price corresponding to the shipment and/or delivery of the
Product.
13.2 Notwithstanding any provisions of any applicable laws including common law, any additional or different terms and
conditions set forth in Buyer's purchase order are objected to by ALSTOM Grid, Inc. and will not be binding upon
ALSTOM Grid, Inc. unless specifically assented to in writing by an authorized representative of ALSTOM Grid, Inc."
13.3 Buyer's purchase order shall constitute an acceptance of the quotation or proposal of ALSTOM Grid, Inc. even if the
purchase order provides otherwise and/or does not reference the ALSTOM Grid, Inc. quotation or proposal. To the extent
permitted by law, the so-called "knock out" rule, in which differing terms between an offer and acceptance are knocked
out and are not deemed part of the resulting contract between the parties, shall not apply to this contract."
13.4 Notwithstanding anything to the contrary, the quotation of Seller for this project which include these exceptions
and clarifications shall take precedence over any other documents including the Request for proposal documents.
13.5 Any right to set off sums owed to the Seller, if any, shall be restricted to sums owed by either party to the other one
under this contract.