You are on page 1of 5

G PT. GA-!

"X*H,IBADI
M
REINFORGED GONCRETE PIPE (RGP

ffi** SOCKET . SPIGOT JOINT

STANDARD SPECIFICATION CLASS LD I & MD 2 REINFORCED CONCRETE PIPE (RCP}

Dia. 300 300 370 440 35 a4 2450 240


ffit
24',1
Dia. 400 410 480 550 35 88 2450 335 337
Dia.500 s10 600 700 45 ,t04 2450 545 548
Dia. 600 630 720 840 45 't07 2450 685 690
Dia. 800 850 960 1120 55 1ts 2450 't 168 1180
Dia. 1000 1070 1200 1400 65 131 2450 't802 1A2A
Dia. 1200 1280 1440 1680 80 160 2450 2686 2713
Dia.1500 't500 1440 2100 150 160 24sO 4526

STANDARD SPECIFICATION CLASS MD 3 & HD 4 REINFORCED CONCRETE PIPE (RCP}

Dia. 300 300 370 440 35 a4 2450 252 253


Dia- 400 400 480 560 40 88 2450 379 380
Dia. 500 500 600 700 50 104 2450 600 603
Dia. 600 600 720 840 60 107 2450 873 878
Dia. 800 800 960 1120 80 115 2450 1s82 1592
Dia. 1000 1000 1200 1400 100 131 2450 2526 2541
Dia. 1200 't200 1440 1680 120 160 2450 3674 3691
Dia. 1500 1500 1MO 2',too '150 160 2450 5949 5959
Remarks :
1. All dimensions are in milimetre (mm)
2. Minimum concrete strength 500kg/cft $
3. Pipes are be designed and manufactured to withstand Load Testing requirement
Ligth Duty (LD) A5-1342-1973 Ciass I , Iredium Duty (MD) A5-4058-1992 Class 2 and 3,
Heavy Duty (HD) AS-4058-1992 Class 4
4. Class 1 pipes are not recommended to withstand Live Load such as HS-20 Truck AASHTO
unless approved By our Technical Service Engineer
5. Data is subject to change without notice

Surabaya Office Representative : Factory :


- Telp. 031 5631288 Desa Karangkuten
- Fax. 031 5631288 Kec. Gondang - Mojokerto
Website : http://www.calvaryabadi.com
ffi Pr. GALV
Precast Concrete H_lBADl m
REINFORCED GONGRETE PIPE

Gr-.
l
SOCKET - SPIGOT JOINT

STANDARD SPECIFICATION LOAD TEST RE

EErrgu
Dia. 300 't2.0 18.0 't5.0 20.0 23.0 34.0 30.0 45.0
Dia. 400 14.0 22.O 18.0 27.0 27.O 41.O 36.0 54.0
Dia. 500 16.0 25.O 22.O 33.0 33.0 50.0 44-0 66.0
Dia. 600 19.0 28.5 26.0 39.0 39.0 59-0 52.O 78.0
Dia. 800 22.0 33.0 34.0 51.0 51.0 76.0 67.0 10'1.0
Dia. 1000 24.O 37.O 41.O 61.0 61,0 9t.0 81.0 121.O
Dia. '1200 27 -O 40_5 46.0 59.0 69.0 't04.0 92.0 138-0
Dia. 1500 54.0 81.0 81.0 122.O 108.0 162.O

Remarks :
'1.All dimensions are in milimetre (mm)
2. Minimum concrete strength 500 kg/cfr
3. Pipes are be designed and manufactured to withstand Load Testing requirement
Ligth Duty (LD) ASl342-1973 Class 1 , Medium Duty (MD) AS-4058-1992 Class 2 and 3,
Heavy Duty (HD) AS-4058-1992 Class 4
4. Class 1 pipes are not recommended to withstand Live Load such as HS-20 Truck AASHTO
unless approved By our Technical Service Engineer
5. Data is subject to change without notice

Surabaya Office Representative : Factory :


- Telp. 031 5631288 Desa Karangkuten
- Fax. 03'1 5631288 Kec. Gondang - Mojokerto
Website : http ://www.calvaryabadi.com
E Pr. GALV
Precast Concrete *I.lBADl m
BOX GULVERT

STANDARD SPECIFICATION BOX CULVERT

BC 600 600 600 100 100 800 't200 1100

BG 8OO 800 800 110 110 1020 1200 1420


BC 1000 1000 1000 125 125 't250 1200 1990

BC 1200 1200 1200 150 150 1500 1200 2870


BC 1500 1500 1500 1s0 150 1800 1200 3450
BC 1500 1500 1500 200 200 1900 1200 4570
BC 2000 2000 2000 200 200 2400 1200 5830

Remarks :

1. All dimensions are in milimetre (mm)


2. Minimum concrete strength 350 kg/cm'
3. Reinforcement steel physical U 24 , U 40 and U 50 (JlS 45305 ; JtS 5345)
4. Another size and type or special condition are supplied produced on request
5. Data is subject to change without notice

Surabaya Office Representative : Factory:


- Telp. 031 5631288 Desa Karangkuten
- Fax. 031 5631288 Kec. Gondang - Mojokerto
Website : http://www.calvaryabadi.com
ffi Pr' co-!"x**I,rBADl
m
U.DITGH
rI
tla W
iItla

STANDARD SPECIFICATION U-DITGH

U 30x20x120 300 200 50 55 50 '1200 140


U 30x30x120 300 300 50 55 50 1200 180
U 30x40x120 300 400 50 55 50 1200 220
t 30x50x120 300 500 50 55 50 1200 250
U 40x40x120 400 400 60 65 60 1200 280
U 40x50x120 400 500 60 65 60 't200 330
U 40x60x120 400 600 60 65 60 1200 370
U 50x50x120 500 500 60 65 60 1200 340
U 50x60x120 500 600 60 70 60 1200 390
U 50x70x120 500 700 60 80 60 1200 430
U 60x60x'120 600 600 60 70 60 1200 410
U 60x70x120 600 700 60 70 60 1200 450
U 60x80x{ 20 600 800 80 95 80 1200 650
U 60x100x120 600 1000 80 95 80 't200 800
U 7Ox7Ox12O 700 700 80 95 80 ,1200
700
U 70x80x120 700 800 80 95 80 1200 720
U 80x80x120 800 800 80 95 80 1200 730
O 80x90x120 800 900 80 95 80 1200 790
U 80x100x120 800 1000 't 00 110 100 1200 '1000
U 80x120x120 800 1200 100 'tt0 100 1200 1170
U 90x90r120 900 900 100 115 100 1200 1200
U 90x100x120 900 1000 100 115 {00 1200 1280
t, 1001100x120 1000 1000 100 115 100 1200 1150
U 100x120x120 1000 1200 100 115 100 1200 1330
U'100x150x120 1000 1500 120 135 '120 1200 1880
U 12Ox1OOx12O 1200 '1000 120 't3s 120 1200 1440
U 120x120x120 '1200 1200 120 135 120 1200 16't 0
U 120x150x120 1200 't 500 120 135 '120 1200 1900
Remarks :
'1-
Alldimensions are in milimet.e (mm)
2. Minimum concrete strength 350 kg/cm'
3. Reinforcement steel physical U 24 , U 40 and U 50 (JlS 45305 ; JIS 5345)
4. Another size and type or special condition are supplied produced on request
5. Data is subjeci to change without notice

Surabaya Off ice Representative : Factory:


- Telp. 031 5631288 Desa Karangkuten
- Fax. 031 5631288 Kec. Gondang - Mojokerto
Website : http://www.calvaryabadi.com
H Pr. GALV
Precast Goncrete *I_lBADt m
pouBLE u Box (puB).

DUB TOP COIMPONENT

STANDARD SPECIFICATION DOUBLE U BOX (DUB)

DUB 120.'120 1200 1200 600 150 165 150 150 1200
DUB 150.150 1500 1500 750 150 165 ,50 150 1200
DUB 200.200 2000 2000 1000 200 225 200 200 1200
DUB 2s0.250 2500 2500 1250 200 225 250 250 '1200
DUB 300.300 3000 3000 1500 250 275 250 300 1200
DUB 350.3s0 3500 3500 1750 300 325 300 300 1200
DUB 400.400 4000 4000 2000 300 325 300 350 1200
DUB 450.450 4500 4500 2250 350 375 350 400 1200
DUB 500.490 5000 4900 2450 400 425 400 450 1200
DUB 600.490 6000 4900 2450 450 475 450 500 1200

Remarks :

1. All dimensions are in milimetre (mm)


2. Concrete strength 350 kg/cm' and 400 kg/cm'
3. Reinforcemenl steel physical U 24 and U 40 (JlS 45305 : JIS 5345)
4. Another size and type or special condition are supplied produced on request
5. Data is subject to change without notice
6. Joint plate system is quicklay joint

Surabaya Office Representative : Factory :


- Telp. 031 5631288 Desa Karangkuten
- Fax. 031 5631288 Kec. Gondang - Mojokerto