DEAD SET
BURN RY22
SHORTED TO GROUND THE CRT SOCKET AND
NEED TO REPLACED A NEW ONE
IF NO GREEN COLOR OR VOLTAGE UP TO 185V VY06 NEED TO REPLACE
STANDBY NO OTHER ACTION OF THE TV SET
HANG UP C839, IF IT WORKS D831 DEFECTIVE AND
OTHER RELATED X-RAY PROTECTION CIRCUITS.
- TRY TO CHANGE EEPROM,
- AUDIO DEMODULATOR
- A1569=3.3V REGULATOR
- REGULATOR = STR G8653 OR 8656
OSCILATE NO PICTURE NO HEATER
NO VOLTAGE IN D831 CHANGE IC BUS AND MEMORY
- 190V = 150 ONLY AND ABNORMAL
- 30V GOOD IF FLYBACK HANG UP BUT DECREASE IF CONNECTED
- H-DRIVE AND PRE-DRIVE GOOD
- R841 CHANGE VALUE = 15K BECOME 25K Ohms
- R260 OPEN